Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “testing standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Results of IEC 62804 Draft Round Robin Testing (Presentation)

Three crystalline silicon module designs were distributed in five replicas each to five laboratories for testing according to the IEC 62804 (Committee Draft) system voltage durability qualification test for crystalline silicon photovoltaic (PV) modules. The stress tests were performed in environmental chambers at 60 degrees C, 85% relative humidity, 96 h, and with module nameplate system voltage applied.

14 SOLAR ENERGY↗

Design and Development of a Residential Gas-Fired Heat Pump

Heating, ventilating, and air-conditioning equipment consumes 43% of the total primary energy consumption in U.S. households. Presently, conventional gas furnaces have maximum heating efficiencies of 98%. Electric air conditioners used in association with the furnace for cooling have a minimum seasonal energy efficiency ratio (SEER) of 14.0. A residential gas-fired heat pump (RGHP) was developed and tested under standard rating conditions, resulting in a significant increase in heating efficiency of over 40% versus conventional natural gas furnaces. The associated efficiency of the RGHP in cooling mode is comparable in efficiency to an electric air conditioner (14.0 SEER) when compared on a primary energy basis. The RGHP is similar in nature to a conventional heat pump but with two main differences. First, the primary energy savings are higher, based on a site versus source comparison, as the result of using natural gas to supply shaft power to the compressor rather than an electric motor. Second, waste heat is recovered from the engine to supplement space heating and reduce the energy input. It can also be used to provide supplemental water heating. The system utilizes a programmable logic controller that allows variable-speed operation to achieve improved control to meet building loads. RGHPs significantly reduce peak electric use during periods of high demand, especially peak summer loads, as well as peak winter loads in regions with widespread use of electric heating. This contributes to leveling year-round gas loads, with the potential to increase annual gas demand in some regions. The widespread adoption of RGHPs will contribute to significant reductions in primary energy consumption and carbon emissions through improved efficiencies.

energy efficiency↗

Meso-modeling of Carbon Fiber Composite for Crash Safety Analysis

In the conventional approach, the material properties for crash safety simulations are typically obtained from standard coupon tests, where the test results only provide single layer material properties used in crash simulations. However, the lay-up effects for the failure behaviors of the real structure were not considered in numerical simulations. Hence, there was discrepancy between the crash simulations and experimental tests. Consequently, an intermediate stage is required for accurate predictions. Some component tests are required to correlate the material models in the intermediate stage. In this paper, a Mazda Tube under high-impact velocity is chosen as an example for the crash safety analysis. The tube consists of 24 layers of uni-directional (UD) carbon fiber composite materials, in which 4 layers are perpendicular to, while the other layers are parallel to the impact direction. An LS-DYNA meso-model was constructed with orthotropic material models counting for the single-layer material behaviors. Between layers, a node-based tie-break contact was used for modeling the delamination of the composite material. Since fiber directions are not single-oriented, the lay-up effects could be an important effect. From the first numerical trial, premature material failure occurred due to the use of material parameters obtained directly from the coupon tests. Some parametric studies were conducted to identify the cause of the numerical instability. The finding is that the material failure strength used in the numerical model needs to be enlarged to stabilize the numerical model. Some hypothesis was made to provide the foundation for enlarging the failure strength and the corresponding experiments will be conducted to validate the hypothesis.

Lin, Shih-Po↗

Density Matrix Quantum Circuit Simulation via the BSP Machine on Modern GPU Clusters

As quantum computers evolve, simulations of quantum programs on classical computers will be essential in validating quantum algorithms, understanding the effect of system noise, and design applications for future quantum computers. In this paper, we propose a novel multi-GPU programming model called MG-BSP that constructs a virtual BSP machine on top of modern multi-GPU platforms, and tweak the programming model to build a multi-GPU density matrix quantum simulator. We propose and evaluated a new formulation minimizing communication and prove that the transformation conserves original semantics when noise is introduced. We build the tool-chain to support quantum assembly open standard, synthesize testing quantum circuit, and enable ultra-deep quantum simulation. We evaluated our design on four state-of-the-art multi-GPU platforms including the latest DGX-1 and DGX-2 systems. We demonstrate simulation of 1 million gates in 94 minutes, far deeper circuits than has been demonstrated in prior work. A roofline-model analysis show that we have reached near-optimal performance under memory bound.

Li, Ang↗

Sealability Qualification of Material Extruded Zytel Gaskets at Extreme Temperatures

In this work, an in-depth qualification of additively manufactured Zytel for gasketing proton exchange membrane fuel cells (PEMFC’s) subject to extreme temperature conditions. The temperature cycling of the PEMFC from 55°C to 100°C accelerates the deterioration of these gaskets compared to that of conventional operation. The additive manufacturing process employed to print these gaskets is material extrusion using Zytel filament. In order to see the effects of the temperature of interest on the printed specimen, each specimen was thermally soaked and then charactered and tested according to ASTM standard F37B. ASTM F37B tests a materials ability to seal and maintain it while bearing both a compressive load and internal pressure load to simulate being in static operation. This process of thermally soaking and sealability testing is shown to show the validity of both this material and additive manufactured components for other applications as well. It is observed that soaking the gaskets at 100°C corrects some of the defects that are present after printing such as missing layers and small voids on the surface of the samples. This allowed for the hot soaked materials to perform better than the samples at room temperature and cold soaked.

Sealability↗

A Revised International Standard for Gearboxes in Wind Turbine Systems

Gearbox and wind turbine design and application standards have contributed significantly to improvements in reliability over the past two decades. The International Electrotechnical Commission (IEC) 61400-4 standard of wind turbine gearbox design is currently being revised by a joint working group (JWG) of experts in IEC TC 88 (wind energy) and International Organization for Standardization (ISO) TC60 (gears) to further that effort. Experts from ISO TC4 (rolling bearings) and ISO TC28 (lubricants) have actively participated. This revision has implemented lessons learned from industry use of edition 1 since its publication in 2012. The main document, IEC 61400-4, was pared down to essential design requirements and application-specific recommendations along with a design verification framework. The JWG leveraged concurrent development of other standards, such as IEC 61400-8 on wind turbine structures, to replace edition 1 content. These are described along with how this works with the IEC Renewable Energy certification scheme for wind turbines (IECRE-WE). The JWG recognized the interest in maintaining informative parts of edition 1 including annexes on wind turbine architecture and loads, bearing and gear arrangements, bearing selection, lubrication system descriptions and lubricant performance recommendations. This information was retained in two technical reports: IEC/TR 61400-4-2 Lubrication and IEC/TR 61400-4-3 Explanatory Notes. Additionally, a technical specification, IEC/TS 61400-4-1, was drafted to provide a reliability calculation method for comparing different design options or conditions. Salient elements of these documents are described. All four documents were recently distributed for IEC/ISO review, ballot, and comment. Publication is expected in 2023.

gearbox↗

A Revised International Standard for Gearboxes in Wind Turbine Systems: Preprint

Gearbox and wind turbine design and application standards have contributed significantly to improvements in reliability over the past two decades. The International Electrotechnical Commission (IEC) 61400-4 standard of wind turbine gearbox design is currently being revised by a joint working group (JWG) of experts in IEC TC 88 (wind energy) and International Organization for Standardization (ISO) TC60 (gears) to further that effort. Experts from ISO TC4 (rolling bearings) and ISO TC28 (lubricants) have actively participated. This revision has implemented lessons learned from industry use of edition 1 since its publication in 2012. The main document, IEC 61400-4, was pared down to essential design requirements and application-specific recommendations along with a design verification framework. The JWG leveraged concurrent development of other standards, such as IEC 61400-8 on wind turbine structures, to replace edition 1 content. These are described along with how this works with the IEC Renewable Energy certification scheme for wind turbines (IECRE-WE). The JWG recognized the interest in maintaining informative parts of edition 1 including annexes on wind turbine architecture and loads, bearing and gear arrangements, bearing selection, lubrication system descriptions and lubricant performance recommendations. This information was retained in two technical reports: IEC/TR 61400-4-2 Lubrication and IEC/TR 61400-4-3 Explanatory Notes. Additionally, a technical specification, IEC/TS 61400-4-1, was drafted to provide a reliability calculation method for comparing different design options or conditions. Salient elements of these documents are described. All four documents were recently distributed for IEC/ISO review, ballot, and comment. Publication is expected in 2023.

ENGINEERING,WIND ENERGY↗

The Qweak Experiment: A Search for New Physics at the TeV Scale via a Measurement of the Proton's Weak Charge

The \mbox{Qweak} experiment at Jefferson Lab will measure the parity-violating elastic electron-proton scattering asymmetry at $\mathrm{Q^2} \simeq \mathrm{0.03(GeV/c)^2}$ to obtain the weak charge of the proton, $\mathrm{Q^p_W}$, to an accuracy of $\mathrm{4\%}$. The result will test the Standard Model prediction of the running of $\mathrm{\sin^2 \theta_W}$ and will provide an indirect probe of new physics at $\mathrm{TeV}$ scale. An overview and the performance of the experiment after the first data taking run will be provided.

Beminiwattha, Rakitha↗

The Qweak Experiment at Jefferson Laboratory

The Qweak Collaboration at Jefferson Lab will perform the first direct measurement of the proton?s weak charge, to a precision of 4% by measuring the parity-violating asymmetry in elastic electron-proton scattering. This asymmetry is expected to be small, 250 ppb and is proportional to the proton?s weak charge. At tree level, this correspond to a 0.3% measurement of the weak mixing angle, making this the best low energy measurement to date. This measurement will test the Standard Model prediction for the running of the weak mixing angle and be sensitive to new parity violating physics at the TeV scale. In combination with previous precision parity violation measurements an extraction of the neutral-weak effective couplings C1u and C1d can be performed. The experiment is currently running in Hall C at JLab, with a projected completion date of May 2012. The status and methodology of the experiment will be discussed in this talk. Preliminary measurements may be presented.

Carlini, Roger↗

Performance Evaluation of Axial Flow AG-1 FC and Prototype FM (High Strength) HEPA Filters - 13123

High efficiency particulate air (HEPA) filters are routinely used in DOE nuclear containment activities. The Nuclear Air Cleaning Handbook (NACH) stipulates that air cleaning devices and equipment used in DOE nuclear applications must meet the American Society of Mechanical Engineers (ASME) Code on Nuclear Air and Gas Treatment (AG-1) standard. This testing activity evaluates two different axial flow HEPA filters, those from AG-1 Sections FC and FM. Section FM is under development and has not yet been added to AG-1 due to a lack of qualification data available for these filters. Section FC filters are axial flow units that utilize a fibrous glass filtering medium. The section FM filters utilize a similar fibrous glass medium, but also have scrim backing. The scrim-backed filters have demonstrated the ability to endure pressure impulses capable of completely destroying FC filters. The testing activities presented herein will examine the total lifetime loading for both FC and FM filters under ambient conditions and at elevated conditions of temperature and relative humidity. Results will include loading curves, penetration curves, and testing condition parameters. These testing activities have been developed through collaborations with representatives from the National Nuclear Security Administration (NNSA), DOE Office of Environmental Management (DOE-EM), New Mexico State University, and Mississippi State University. (authors)

42 ENGINEERING↗

Secondary Waste Form Development and Data Package for Hanford's Integrated Disposal Facility Performance Assessment - 16479

The Hanford Low-Activity Waste (LAW) Vitrification facility is planned to immobilize Hanford tank waste for on-site, near-surface disposal at Hanford's Integrated Disposal Facility (IDF). During this process, liquid and solid secondary wastes will be generated which are also slated for disposal at the IDF. In order to receive authorization to dispose of the waste in the IDF, a Performance Assessment (PA) must be completed in accordance with DOE Order 435.1, Radioactive Waste Management, and its accompanying Manual. The PA must include calculations of potential doses to a member of the public for a 1,000-year period to provide a reasonable expectation that performance objectives will not be exceeded and that the waste will be managed in a manner that is protective of worker and public health and safety, and the environment. Liquid and solid secondary wastes are planned to be immobilized within cementitious waste forms similar to those used elsewhere in the United States and around the world for permanent disposal of low-level radioactive waste (LLW). Data packages and supporting documents are being developed to provide the technical underpinning for the analyses of contaminant releases to the environment from these waste forms for the IDF PA. Traditionally, releases from cementitious waste forms have utilized a diffusion-limited release model using contaminant-specific diffusivities measured in standard leach tests as inputs. More mechanistic modeling techniques are under development to increase the rigor of the PA analyses. In addition, recent testing has shown diffusivities of key contaminants can be reduced by several orders-of-magnitude through optimized formulation of the waste form and use of additives to bind specific contaminants. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance Evaluation of AG-1 FC Filters Under Upset Conditions and the Effects of Aging on Filters - 19501

High efficiency particulate air (HEPA) filters are routinely used in nearly every operating Department of Energy (DOE) and National Nuclear Safety Administration (NNSA) nuclear facility. These nuclear grade HEPA filters installed in DOE and NNSA confinement ventilation systems are credited as the final barrier to protect the environment, the public, and the worker from accidental release of virtually all airborne radioactive materials, and must meet the American Society of Mechanical Engineers' (ASME) Code on Nuclear Air and Gas Treatment (CONAGT) AG-1 standard. This testing activity evaluates ASME AG-1 Section FC axial flow HEPA filters, both separator and separator-less, under upset conditions. Additionally, testing efforts have analyzed the effects of filter degradation due to aging. In 1997, the Defense Nuclear Facilities Safety Board (DNFSB) raised concerns of the potential vulnerability of HEPA filters in vital safety systems, both from a design stand point and the potential for degradation of HEPA filter performance over time. The DOE Office of Environmental Management (DOE-EM) has a Cooperative Agreement with Mississippi State University (MSU) Institute for Clean Energy Technology (ICET) to conduct testing of HEPA filters. DOE-EM has established a Technical Working Group (TWG) of over thirty subject matter experts from the nuclear industry to provide input and oversight of ICET projects and activities. This has included establishment/approval of testing parameters for evaluating these filters under ASME NQA-1 compliant Test Plans. The current scope of work involves evaluation of the performance envelope for new and aged separator and separator-less designs of AG-1 Section FC axial flow HEPA filters. A range of elevated test conditions (T and RH) are used to determine the operating envelope within which DOE nuclear safety experts can credit installed HEPA filter performance, thereby establishing a risk-informed DOE service life. This paper will present preliminary test results of new and aged axial flow filters tested at ICET. Results in this paper include data collected from new separator and separator-less type FC HEPA filters and equivalent test data for a limited group of aged separator and separator-less type FC HEPA filters. Testing for both scopes of work evaluate initial filter performance under ambient conditions of temperature (60 deg. F - 80 deg. F (∼16 - ∼27 deg. C)) and relative humidity (40-60%), loading of each filter with Aluminum Trihydroxide, Al(OH)3, to a specified differential pressure, and then exposing the filter to specified elevated temperature and relative humidity conditions. In addition to the upset conditions of elevated temperature and relative humidity, the performance of HEPA filters under fire scenarios is not well characterized. ICET is currently designing a burn box and testing apparatus to study the effects of fire from burning liquids and a wide range of blends of combustible solids. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Anomalous Spin Precession Frequency Analysis in the Muon $g-2$ Experiment at Fermilab

The Muon $g-2$ experiment at Fermilab aims to measure the muon anomalous magnetic moment with an unprecedented precision of 140 parts per billion (ppb). Data collection concluded in June 2023, and analysis of the largest dataset (2021-2023) is underway. Previous publications based on data from 2018-2020 established the experimental foundation. This document provides an overview of the measurement of the muon anomalous spin precession frequency ($\omega_a$) and the associated systematic corrections. The precision of these results directly tests the Standard Model's completeness, making the experiment a cornerstone in the field of particle physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analysis Of Fracture Location on Tensile Graphite Samples

The main standard for testing the ultimate tensile strength of graphite is ASTM C749. Commercial entities have raised concerns about samples breaking outside of the gauge section, particularly in the radius or head of the sample. When this occurs, the data gathered from the samples is unusable and increases the cost of testing as more samples will need to be machined. This study investigates the locations and frequency of sample breakage for four different grades of graphite using a custom-made measurement scale. The four grades include two fine-grain (2114 and IG-110) and two medium/coarse-grain (NBG-17 and PCEA). Our results show that fine-grain grades are more susceptible to breaking outside the gauge section, with almost 30% of the samples from grade 2114 breaking outside this region. Additionally, the radius being too small causes stress concentrations near the ends of the gauge section resulting in a bimodal distribution of the fracture locations.

36 - MATERIALS SCIENCE↗

Binary Pseudo-Random Gratings and Arrays for Calibration of Modulation Transfer Functions of Surface Profilometers

A technique for precise measurement of the modulation transfer function (MTF), suitable for characterization of a broad class of surface profilometers, is investigated in detail. The technique suggested in [Proc. SPIE 7077-7, (2007), Opt. Eng. 47(7), 073602-1-5 (2008)]is based on use of binary pseudo-random (BPR) gratings and arrays as standard MTF test surfaces. Unlike most conventional test surfaces, BPR gratings and arrays possess white-noise-like inherent power spectral densities (PSD), allowing the direct determination of the one- and two-dimensional MTF, respectively, with a sensitivity uniform over the entire spatial frequency range of a profiler. In the cited work, a one dimensional realization of the suggested method based on use of BPR gratings has been demonstrated. Here, a high-confidence of the MTF calibration technique is demonstrated via cross comparison measurements of a number of two dimensional BPR arrays using two different interferometric microscopes and a scatterometer. We also present the results of application of the experimentally determined MTF correction to the measurement taken with the MicromapTM-570 interferometric microscope of the surface roughness of a super-polished test mirror. In this particular case, without accounting for the instrumental MTF, the surface rms roughness over half of the instrumental spatial frequency bandwidth would be underestimated by a factor of approximately 1.4.

47 OTHER INSTRUMENTATION↗

Binary Pseudo-Random Gratings and Arrays for Calibration of Modulation Transfer Functions of Surface Profilometers

A technique for precise measurement of the modulation transfer function (MTF), suitable for characterization of a broad class of surface profilometers, is investigated in detail. The technique suggested in papers Yashchuk et al. (2007), Yashchuk et al. (2008) is based on use of binary pseudo-random (BPR) gratings and arrays as standard MTF test surfaces. Unlike most conventional test surfaces, BPR gratings and arrays possess white-noise-like inherent power spectral densities (PSD), allowing the direct determination of the one- and two-dimensional MTF, respectively, with a sensitivity uniform over the entire spatial frequency range of a profiler. In the cited work, a one-dimensional realization of the suggested method based on use of BPR gratings has been demonstrated. Here, a high performance of the MTF calibration technique is demonstrated via cross comparison measurements of a number of two-dimensional BPR arrays using two different interferometric microscopes and a scatterometer. We also present the results of application of the experimentally determined MTF correction to the measurement taken with the Micromap{trademark}-570 interferometric microscope of the surface roughness of a super-polished test mirror. In this particular case, without accounting for the instrumental MTF, the surface rms roughness over half of the instrumental spatial frequency bandwidth would be underestimated by a factor of approximately 1.4.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE PRODUCT CONSISTENCY TEST HOW AND WHY IT WAS DEVELOPED

The Product Consistency Test (PCT), American Society for Testing Materials (ASTM) Standard C1285, is currently used world wide for testing glass and glass-ceramic waste forms for high level waste (HLW), low level waste (LLW), and hazardous wastes. Development of the PCT was initiated in 1986 because HLW glass waste forms required extensive characterization before actual production began and required continued characterization during production ({ge}25 years). Non-radioactive startup was in 1994 and radioactive startup was in 1996. The PCT underwent extensive development from 1986-1994 and became an ASTM consensus standard in 1994. During the extensive laboratory testing and inter- and intra-laboratory round robins using non-radioactive and radioactive glasses, the PCT was shown to be very reproducible, to yield reliable results rapidly, to distinguish between glasses of different durability and homogeneity, and to easily be performed in shielded cell facilities with radioactive samples. In 1997, the scope was broadened to include hazardous and mixed (radioactive and hazardous) waste glasses. In 2002, the scope was broadened to include glass-ceramic waste forms which are currently being recommended for second generation nuclear wastes yet to be generated in the nuclear renaissance. Since the PCT has proven useful for glass-ceramics with up to 75% ceramic component and has been used to evaluate Pu ceramic waste forms, the use of this test for other ceramic/mineral waste forms such as geopolymers, hydroceramics, and fluidized bed steam reformer mineralized product is under investigation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗