High Temperature Molten Salt Furnaces " ARRA Funded Purchase" Item 1.9 and 7.2 High Temperature Furnace.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Abstract not provided.
Abstract not provided.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Although a great deal is known about the interaction between water and rhyolitic glasses and melts at temperatures above the glass transition, the nature of this interaction at lower temperatures is much more obscure. Comparisons between high- and low-temperature diffusion studies suggest that several factors play important roles under lower-temperature conditions that are not significant at higher temperatures. Water concentrations in rhyolitic glasses hydrated at low temperatures are significantly greater than in those hydrated at high temperatures and low pressures. Surface concentrations, which equilibrate quickly with the surrounding environment at high temperature, change far more slowly as temperature decreases, and may not equilibrate at room temperature for hundreds or thousands of years. Temperature extrapolations of high- and low-temperature diffusion data are not consistent, suggesting that a change in mechanism occurs. These differences may be due to the inability of "self-stress," caused by the in-diffusing species, to relax at lower temperature. Preliminary calculations suggest that the level of stress caused by glass-water interaction may be greater than the tensile strength of the glass. On a microstuctural scale, extrapolations of high-temperature Fourier transform infrared spectroscopy (FTIR) data to lower temperatures suggests that there should be little or no hydroxyl present in glasses hydrated at low temperature. Comparisons of low-temperature hydration results among SiO2, obsidian, and albite compositions show distinct differences, and features are present in the spectra that do not occur at high temperature. Analysis of H2O and D2O diffusion also suggest that mechanistic differences occur between low- and high-temperature diffusive processes.
Highlights: • Temperature and relative humidity have opposing effects on evaporative water loss. • Wet-bulb temperatures best predicted kidney stone presentations. • Differences in predictive capacity of temperature metrics were greatest in summer. Temperature and relative humidity have opposing effects on evaporative water loss, the likely mediator of the temperature-dependence of nephrolithiasis. However, prior studies considered only dry-bulb temperatures when estimating the temperature-dependence of nephrolithiasis. We used distributed lag non-linear models and repeated 10-fold cross-validation to determine the daily temperature metric and corresponding adjustment for relative humidity that most accurately predicted kidney stone presentations during hot and cold periods in South Carolina from 1997 to 2015. We examined three metrics for wet-bulb temperatures and heat index, both of which measure the combination of temperature and humidity, and for dry-bulb temperatures: (1) daytime mean temperature; (2) 24-h mean temperature; and (3) most extreme 24-h temperature. For models using dry-bulb temperatures, we considered four treatments of relative humidity. Among 188,531 patients who presented with kidney stones, 24-h wet bulb temperature best predicted kidney stone presentation during summer. Mean cross-validated residuals were generally lower in summer for wet-bulb temperatures and heat index than the corresponding dry-bulb temperature metric, regardless of type of adjustment for relative humidity. Those dry-bulb models that additionally adjusted for relative humidity had higher mean residuals than other temperature metrics. The relative risk of kidney stone presentations at the 99th percentile of each temperature metric compared to the respective median temperature in summer months differed by temperature metric and relative humidity adjustment, and ranged from an excess risk of 8–14%. All metrics performed similarly in winter. The combination of temperature and relative humidity determine the risk of kidney stone presentations, particularly during periods of high heat and humidity. These results suggest that metrics that measure moist heat stress should be used to estimate the temperature-dependence of kidney stone presentations, but that the particular metric is relatively unimportant.
The performance of photovoltaic (PV) modules is primarily influenced by the plane of array (POA) irradiance and their operating temperature. The lower the module operating temperature, the higher is its performance. Increasing a module’s operating temperature reduces its power output due to an increase in the semiconductor’s intrinsic carrier density, leading to a reduction in the open-circuit voltage and, subsequently, reducing the maximum power point voltage. Reducing the operating temperature lowers the levelized cost of energy (LCOE) via increased energy production (i.e., more kilowatt hour over the life of the asset) and increased service lifetime (years in the field). The module operating temperature is dictated by the weather parameters and the thermal properties of module construction materials. The primary weather parameters influencing the PV module temperature are: the ambient temperature (directly related), irradiance (directly related), and wind speed (inversely related). The primary thermal properties of module construction materials influencing the PV module temperature are: the optical transmissivity and thermal conductivity of superstrate, the thermal conductivity of substrate, the thermal conductivity of encapsulant and the efficiency of the encapsulated solar cells. The primary goal of this study is to reduce the operating temperature of PV modules using thermally conductive backsheet (TCB) substrates developed by the industry. The temperature of PV modules installed in a large multi-MW plant can also be influenced by their physical locations in the plants due to the influence of wind direction. A thermal mapping of PV plants has also been investigated and presented in this study. The most commonly used PV backsheet material has been polyvinyl fluoride (DuPont trade name “Tedlar”)-based backsheet, which typically has three layers: Tedlar–polyethylene terephthalate (PET)–Tedlar (TPT). The primary goal of this project is to reduce the module operating temperature below the benchmark TPT backsheet temperature using newly developed TCBs by the industry. The overall approach of this project involves six focus areas: i) select and procure one TPT and thirteen promising TCBs available in the industry; ii) construct a large number of 1-cell and 9-cell modules using benchmark TPT and selected TCBs [all other construction materials are fixed and they are: glass superstrate, EVA encapsulant, mono-Si cell and junction box]; iii) to identify best performing TCBs, monitor the long-term field operating temperatures of the constructed modules which are installed in three climatic conditions (hot-low wind [Mesa, AZ], hot-high wind [Maricopa County, AZ] and temperate [Cumberland County, NC]; iv) to identify the most durable TCB, perform extended accelerated reliability testing of modules constructed with best three TCBs and benchmark TPT; v) to predict module temperature, develop physical and empirical thermal models with and without thermal properties of all construction materials in the modules, respectively; and vi) to determine the influence of wind speed and direction on the module operating temperature in a plant, and perform thermal mapping of PV modules in two large PV plants [Maricopa County, AZ and Cumberland County, NC]. The key achievements of this project are listed below: Backsheet selection: 14 backsheets were procured after an extensive literature and industry search. Finally, based on the thermal and other selection criteria, 1 TPT and 4 thermally conductive backsheets were selected for this project. Fabrication of mini modules: 50 one-cell modules were fabricated in year 1 for thermal performance evaluation. The module design was changed to nine-cell module at start of year 2 to mimic commercial design. 20 nine-cell modules were fabricated in year 2 for thermal performance evaluation. 28 four-cell modules were fabricated in year 3 for accelerated stress-testing. Thermal conductivity of backsheets: Year 1 TCBs showed at least 8% higher thermal conductivities than TPT. Year 2 and 3 TCBs showed at least 20% higher thermal conductivities than TPT. Installation of mini PV modules at three sites: 6 one-cell modules and 8 nine-cell modules were installed at AZ-1 site [Mesa, AZ]. 12 one-cell modules and 6 nine-cell modules were installed at each of two powerplants (AZ-2 [Maricopa County, AZ] and NC sites). Nominal operating cell temperatures (NOCT) of mini PV modules: NOCT of TCBs were observed to be lower than TPT with differences as high as 2°C. Comparison of thermal performance: The median operating temperature of one-cell modules was found to be reduced by 2°C by using TCB_A modules compared to TPT modules on several days in a month for few months in a year. The median temperature improvement of 4oC was achieved at several instances on a few days, but not all days, in a year using multiple TCBs compared to TPT. The final project milestone of achieving median temperature improvement of 5oC was achieved at several instances on a few days, but not all days, in a year using TCB_A compared to TPT. Empirical thermal model (without the need of construction material properties): Empirical thermal model for one-cell module was developed based on the input data of irradiance, wind speed and ambient temperatures. The primary input data differentiator for temperature differences between TPT and TCBs appears to be the irradiance level (solar gain). Accelerated durability testing: 20 four-cell modules using 4 backsheets (1 TPT and 3 TCBs) were exposed to Damp Heat 1000 hours (8 modules), UV/Thermal cycling (50 cycles)/Humidity freeze (10 cycles) test sequence (8 modules) and UV Weathering for qualification (8 modules). All the modules with four selected backsheets passed the stress tests per the retest guidelines of IEC 61215 standard for the backsheet change. Simplified comparative LCOE analysis: Using backsheet-specific power degradation levels in the accelerated tests (for TCB_A and TPT only), efficiency, service lifetime and assuming same cost for all backsheets, the LCOE of modules using TCB_A is determined to be lower than TPT. Due to lower operating temperature of TCB_A-based modules compared to TPT-based modules, the operating efficiency and service life of TCB_A-based modules are calculated to be higher than TPT-based modules. Temperature mapping of PV power plants: A distinct temperature difference (as high as 4°C) has been observed between the modules located in various parts of a single PV plant.
We report that ferroelectricity and piezoelectricity are desirable for a variety of high-temperature applications such as actuators and sensors in heat engines, high-temperature manufacturing, and space technologies; however, the number of such material candidates is currently limited. Here, we demonstrate that CaTiO 3 , the first discovered perovskite mineral that is abundantly found in the Earth, as a non-polar bulk form, becomes a high-temperature ferroelectric oxide under compression. A strain-phase-temperature diagram of CaTiO 3 is created by growing a series of thin films with a range of compressive and tensile strains. Using temperature dependent optical second harmonic generation analysis, we show that tensile strained films exhibit predominantly in-plane polarization with orthorhombic-like point group symmetry with a phase transition below room temperature. On the other hand, compressively strained CaTiO 3 films exhibit a neartetragonal unit cell with a c/a ratio of 1.03, larger than that of classic ferroelectric, e.g. BaTiO 3 (c/a~1.01). These films exhibit a robust and switchable out-of-plane polarization at room temperature, with a ferroelectric transition temperature up to ~800 K. Density functional theory calculations reveal that compressive strain gives rise to a large out-of-plane displacement of Ti-cations inside the TiO 6 octahedral cages responsible for the strain induced polarization of ~ 9μC/cm 2 . Given that nearly half of the perovskites exhibit the bulk symmetry of CaTiO 3 , compressive strain tuning of this family may prove to be a fertile ground for the discovery of strain-induced piezoelectrics and ferroelectrics at high-temperatures. High-temperature piezoelectric sensors are important for many industries such as automotive, aircraft, and aerospace, as well as nuclear and geothermal energy, where dynamic structural monitoring of high-speed rotors in engines, turbines, and power generators is critical for safety and reliability.[1, 2] Modern sensors are however limited, where the main challenges are maximizing operating temperatures while maintaining good sensing capability and low electrical leakage.[3] High-temperature piezoelectric materials are typically derived from BaTiO 3 or PbTiO 3 based ceramics and single crystals, as these materials are also ferroelectric, meaning that they have a built-in spontaneous polarization (Ps). In bulk, these standard ferroelectric perovskite materials yield maximum operating temperatures ranging from 250-450 °C.[4], where above these temperatures the spontaneous polarization (P) and piezoelectric properties disappear due to the onset of a ferroelectric-to-paraelectric phase transition (TC). As next-generation engines, turbines, and reactors require hotter operating temperatures above 500 °C, materials with enhanced ferroelectric properties and increased ferroelectric transition temperatures will be needed in such extreme conditions. A promising way of boosting ferroelectric transition temperatures and polarization is through epitaxial strain engineering,[5] where tremendous in-plane distortions can be applied to thin film crystal materials, well beyond the point at which their bulk ceramic and single crystal counterparts would crack. Strain engineering has proven to drastically enhance ferroelectric polarizations and transition temperatures in classic ferroelectric materials such as BaTiO 3 [6] and PbTiO 3 [7], and strain can even turn on ferroelectricity in otherwise non-polar materials such as SrTiO 3 and CaTiO 3 ,[8] although reported strain-induced ferroelectric transition temperatures are only at room temperature or below.[9-12] In this work, we will focus on strain-induced ferroelectricity in CaTiO 3 , the first discovered perovskite mineral and long known to be a simple nonpolar insulating crystal.
1. Introduction. Wear and erosion damage of materials from solid particle and surface interactions is a major issue in various industries. Although more common in mining and oil and gas production, erosion is becoming a critical issue in renewable technologies as well such as particle based concentrated solar thermal power (CSP) systems. In particle based CSP systems, solid particles are used to absorb solar energy and as thermal storage. However, these particles may cause significant amount of wear to system components while through the system at high temperatures. This damage can be costly, and therefore, requires a greater understanding of solid particle erosion in CSP systems. Throughout the years, models and tools have been developed to predict and control erosion in industries such as oil and gas production. However, these erosion models and erosion prediction tools have been mainly developed based on erosion data for much higher velocities and lower temperatures, i.e. the operating conditions for which the existing models have been built are not pertinent to those expected in CSP system. It is known that erosion depends on many factors such as material properties, erodent particle properties, and particle impact speed and angle. However, the effect of temperature on erosion is not vastly investigated. In this work, a temperature-based correlation is introduced that will be used to modify the existing erosion models to predict erosion rates at velocities and temperatures relevant to Gen3 CSP systems. The existing models are first validated against erosion experiments run at low temperatures and low velocities. Subsequently, a temperature correction term is developed that can extend the existing models to high temperatures, based on the available experimental data showing the effect of temperature on impact erosion. 2. Erosion Models. Continuing sequence of impacts from solid particles on surfaces would result in loss of material due to mechanical interaction between solid surface and particles. Erosion equations have been developed to predict erosion under different conditions and erosion mechanism, including cutting and deformation erosion. These models are mainly either mechanistic, empirical, and semi-mechanistic models, when the latter combine the theory of the erosion mechanism and particle motion with the available experimental data. One of the first empirical correlation was introduced by American Petroleum Institute (API) Recommended Practice (RP) 14E [1]. This correlation was very conservative, and several improved empirical and semi-mechanistic equations were developed in the years following. More recently, the models introduced by Erosion/Corrosion Research Center (E/CRC) at the University of Tulsa and Arabnejad. et al. [2] are frequently used in the literature and industry, as they account for many parameters affecting erosion including particle impact speed and angle, material density and hardness, and particle size and shape. However, both these models were developed based on data at relatively high velocities and also do not take into account any mechanical changes in material associated with thermal cycling at high temperatures. 3. Erosion Prediction at High Temperatures. In this work, the accuracy of Arabnejad et al. model and E/CRC model is investigated to predict impact erosion at conditions relevant to Gen3 CSP systems. Two significant deviations expected in Gen3 systems compared to operating conditions used to build these models are particle impact velocities and system temperature. As a first step, the performance of these models was validated at low velocities and temperatures. Impact erosion experiments were conducted on SS316 coupons using HSP 40/70 ceramic particles. Assuming particle rate of 1 kg/s/m, 0.0254 m of particle curtain thickness, and particle velocity of 1.5 m/s in the system, an overall erosion of 0.59 mm/year was calculated. The experimental results were subsequently compared to those from computational simulations and erosion of 0.47 mm/year was obtained using the Arabnejad et al. model. The results indicated that the models work well at low velocities and low temperature conditions. To account for temperature effect, a mathematical correlation was developed using data published by DUCOM [3] for Inconel 600 eroded by alumina particles at high velocities. The correlation was applied to both Arabnejad et. al model and the E/CRC model. The prediction results from these modified models were within 20% of this experimental data. Predictions of of erosion by the modified E/CRC model at three different temperatures are made. Similar to the calculation at low temperature, a typical CSP system with 1 kg/s/m of particle flow rate per unit length of the particle curtain and a curtain thickness of 0.0254 m is assumed. The annual thickness loss calculations were run for different particle impact velocities, assuming a uniform particle impact area equal to the cross-sectional area of the curtain (particle-particle interactions and dispersion of particles are not considered in obtaining the results). It is observed that erosion increases exponentially as temperature increases. Furthermore, it is also noted that, erosion changes non-linearly with impact velocity. Currently, experiments are also being conducted to measure erosion of SS316 at 800 ºC with HSP 40/70 particles at low impact velocities. We expect to use the results from high temperature testing to further improve the temperature correlation function. Similar models are also being developed for abrasion erosion resulting from particle sliding along the surfaces as well as attrition from particle to particle and particle to surface interactions. References. [1] Institute, A. P. (1991). API Recommended Practice for Design and Installation of Offshore Production Platform Piping System, API RP 14E. [2] Arabnejad, H., Mansouri, A., Shirazi, S. A., and McLaury, B. S. (2015a). Development of mechanistic erosion equation for solid particles. Wear, 332–333, 1044–1050. http://doi.org/10.1016/j.wear.2015.01.031. [3] https://ducom.com/high-temperature-erosion-evaluating-sample-wear/
Control system studies were performed for the Next Generation Nuclear Plant (NGNP) interfaced to the High Temperature Electrolysis (HTE) plant. Temperature change and associated thermal stresses are important factors in determining plant lifetime. In the NGNP the design objective of a 40 year lifetime for the Intermediate Heat Exchanger (IHX) in particular is seen as a challenge. A control system was designed to minimize temperature changes in the IHX and more generally at all high-temperature locations in the plant for duty-cycle transients. In the NGNP this includes structures at the reactor outlet and at the inlet to the turbine. This problem was approached by identifying those high-level factors that determine temperature rates of change. First are the set of duty cycle transients over which the control engineer has little control but which none-the-less must be addressed. Second is the partitioning of the temperature response into a quasi-static component and a transient component. These two components are largely independent of each other and when addressed as such greater understanding of temperature change mechanisms and how to deal with them is achieved. Third is the manner in which energy and mass flow rates are managed. Generally one aims for a temperature distribution that minimizes spatial non-uniformity of thermal expansion in a component with time. This is can be achieved by maintaining a fixed spatial temperature distribution in a component during transients. A general rule of thumb for heat exchangers is to maintain flow rate proportional to thermal power. Additionally the product of instantaneous flow rate and heat capacity should be maintained the same on both sides of the heat exchanger. Fourth inherent mechanisms for stable behavior should not be compromised by active controllers that can introduce new feedback paths and potentially create under-damped response. Applications of these principles to the development of a plant control strategy for the reference NGNP/HTE plant can be found in the body of this report. The outcome is an integrated plant/control system design. The following conclusions are drawn from the analysis: (1) The plant load schedule can be managed to maintain near-constant hot side temperatures over the load range in both the nuclear and chemical plant. (2) The reactor open-loop response is inherently stable resulting mainly from a large Doppler temperature coefficient compared to the other reactivity temperature feedbacks. (3) The typical controller used to manage reactor power production to maintain reactor outlet temperature at a setpoint introduces a feedback path that tends to destabilize reactor power production in the NGNP. (4) A primary loop flow controller that forces primary flow to track PCU flow rate is effective in minimizing spatial temperature differentials within the IHX. (5) Inventory control in both the primary and PCU system during ramp load change transients is an effective means of maintaining high NGNP thermal efficiency while at reduced electric load. (6) Turbine bypass control is an effective means for responding to step changes in generator load when equipment capacity limitations prevent inventory control from being effective. (7) Turbine bypass control is effective in limiting PCU shaft over speed for the loss of generator load upset event. (8) The proposed control strategy is effective in limiting time variation of the differential spatial temperature distribution in the IHX during transients. Essentially the IHX can be made to behave in a manner where each point in the IHX experiences approximately the same temperature rate of change during a transient. (9) The stability of the closed-loop Brayton cycle was found to be sensitive to where one operates on the turbo-machine performance maps. There are competing interests: more stable operation means operating on the curves at points that reduce overall cycle efficiency. Future work should address in greater detail elements that came to light in the course of this work. Specifically: (1) A stability analysis should be performed to identify the phenomena that control reactor outlet temperature stability when operating with the Reactor Outlet Temperature Controller. The goal is to identify a better performing controller. (2) Future simulations should be performed with multiple axial nodes. The single axial node model for the core used in this work gives rise to an initial core reactor outlet temperature perturbation that is a numerical artifact. (3) The tradeoffs referred to above regarding the dependence of Brayton cycle stability and efficiency on performance curve characteristics and use need to be better understood. (4) The role of xenon was neglected in this work and needs to be included in future work.
Silicon carbide (SiC) temperature monitors 05R4-02-A KG1403 (300 LO) and 05R4-01-A KG1415 (400 LO B) were evaluated at the High Temperature Test Lab (HTTL) to determine their peak irradiation temperatures. HTTL measurements indicate that the peak irradiation temperature for the 300 LO monitor was 295 {+-} 20 °C and the peak irradiation temperature for the 400 LO B monitor was 294 {+-} 25 °C. Two silicon carbide (SiC) temperature monitors irradiated in the Advanced Test Reactor (ATR) were evaluated at the High Temperature Test Lab (HTTL) to determine their peak temperature during irradiation. These monitors were irradiated as part of the University of Wisconsin Pilot Project with a target dose of 3 dpa. Temperature monitors were fabricated from high density (3.203 g/cm 3 ) SiC manufactured by Rohm Haas with a nominal size of 12.5 mm x 1.0 mm x 0.75 mm (see Attachment A). Table 1 provides identification for each monitor with an expected peak irradiation temperature range based on preliminary thermal analysis (see Attachment B). Post irradiation calculations are planned to reduce uncertainties in these calculated temperatures. Since the early 1960s, SiC has been used as a post-irradiation temperature monitor. As noted in Reference 2, several researchers have observed that neutron irradiation induced lattice expansion of SiC annealed out when the post-irradiation annealing temperature exceeds the peak irradiation temperature. As noted in Reference 3, INL uses resistivity measurements to infer peak irradiation temperature from SiC monitors. Figure 1 depicts the equipment at the HTTL used to evaluate the SiC monitors. The SiC monitors are heated in the annealing furnace using isochronal temperature steps that, depending on customer needs, can range from 50 to 800 °C. This furnace is located under a ventilation hood within the stainless steel enclosure. The ventilation system is activated during heating so that any released vapors are vented through this system. Annealing temperatures are recorded using a National Institute of Standards and Technology (NIST) traceable thermocouple inserted into an alumina tube in the furnace. After each isochronal annealing, the specimens are placed in a specialized fixture located in the constant temperature chamber (maintained at 30 °C) for a minimum of 30 minutes. After the 30 minute wait time, each specimen's resistance is measured using the specialized fixture and a calibrated DC power analyzer. This report discusses the evaluation of the SiC monitors and presents the results. Testing was conducted in accordance with Reference 3. Sections 2 and 3 present the data collected for each monitor and provide interpretation of the data. Section 4 presents the evaluated temperature results.
We review variable-temperature, transport critical-current ($I_\text{c}$) measurements made on commercial superconductors over a range of critical currents from less than 0.1 A to about 1 kA. We have developed and used a number of systems to make these measurements over the last 15 years. Two exemplary variable-temperature systems with coil sample geometries will be described: a probe that is only variable-temperature and a probe that is variable-temperature and variable-strain. The most significant challenge for these measurements is temperature stability, since large amounts of heat can be generated by the flow of high current through the resistive sample fixture. Therefore, a significant portion of this review is focused on the reduction of temperature errors to less than ±0.05 K in such measurements. A key feature of our system is a pre-regulator that converts a flow of liquid helium to gas and heats the gas to a temperature close to the target sample temperature. The pre-regulator is not in close proximity to the sample and it is controlled independently of the sample temperature. This allows us to independently control the total cooling power, and thereby fine tune the sample cooling power at any sample temperature. The same general temperature-control philosophy is used in all of our variable temperature systems, but the addition of another variable, such as strain, forces compromises in design and results in some differences in operation and protocol. These aspects are analyzed to assess the extent to which the protocols for our systems might be generalized to other systems at other laboratories. Our approach to variable-temperature measurements is also placed in the general context of measurement-system design, and the perceived advantages and disadvantages of design choices are presented. To verify the accuracy of the variable-temperature measurements, we compared critical-current values obtained on a specimen immersed in liquid helium (“liquid” or $I_{\text{c}}$ $_{\text{liq}}$) at 5 K to those measured on the same specimen in flowing helium gas (“gas” or Ic gas) at the same temperature. These comparisons indicate the temperature control is effective over the superconducting wire length between the voltage taps, and this condition is valid for all types of sample investigated, including Nb-Ti, Nb 3 Sn, and MgB 2 wires. The liquid/gas comparisons are used to study the variable-temperature measurement protocol that was necessary to obtain the “correct” critical current, which was assumed to be the $I_{\text{c}}$ $_{\text{liq}}$. We also calibrated the magnetoresistance effect of resistive thermometers for temperatures from 4 K to 35 K and magnetic fields from 0 T to 16 T. This calibration reduces systematic errors in the variable-temperature data, but it does not affect the liquid/gas comparison since the same thermometers are used in both cases.
In this project, we have developed and tested three kinds of fiber optic sensing systems for real time monitoring of temperature variations within an industrial scale boiler furnace. The fiber optic sensing systems target spatial and temporal distributions of high temperature profiles in a boiler furnace in fossil power plants. The reconstructed temperature profile will provide critical input for the control mechanisms to optimize the combustion process. This temperature profile will address the essential problem for fossil power plants in achieving higher efficiency and fewer pollutant emissions. Acoustic pyrometer systems have been used to reconstruct temperature field of power plant boilers based on measuring TOF (times-of-flight) of sound waves along some straight paths in a 2D cross-section of the boiler. In this project, optically generated acoustic signals from a fiber optic sensing system have replaced the acoustic signals generated from an electrical transducer. A 3D reconstruction algorithm replaced the previous 2D model. In this project, three kinds of fiber optic sensing systems have been developed and tested. They are fiber optic sensing system I, fiber optic sensing system II (Distributed Sensing System I) and fiber optic sensing system III (Distributed Sensing System II). For fiber optic sensing system I, the fiber optic ultrasound generator acts as a signal generator. A microphone, hydrophone or other electronic devices serve as a signal receiver. In this system, there are one generator and one receiver. Distance test, water temperature test, air temperature test, air temperature reconstruction, and GE ISBF pilot test were performed by Fiber optic sensing system I. The fiber optic sensing system I successfully detected temperature in all these tests. We got 2D temperature reconstruction results by using the fiber optic sensing system I and it matched the reference data. The fiber optic sensing system I successfully survived in GE ISBF boiler environment (480 °F). For fiber optic sensing system II (Distributed Sensing System I), it is an all optical ultrasound system. The fiber optic ultrasound generator acts as a signal generator. Fiber Bragg Grating (FBG) and Fabry-Perot (FP) sensor act as a signal receiver. In this system, there is one generator and one receiver. Aluminum plate temperature test, furnace high temperature test, and GE ISBF pilot test were performed by the fiber optic sensing system II. Fiber optic sensing system II successfully detected the temperature in all these tests. The fiber optic sensing system II successfully survived at up to 700 °C furnace environment and 320 °C GE ISBF boiler environment. For fiber optic sensing system III (Distributed Sensing System II), it is also an all optical ultrasound system. The fiber optic ultrasound generator acts as a signal generator. Multiple FP fiber sensors act as signal receivers. In this system, there is one generator and three receivers. Three GE ISBF pilot tests were performed by fiber optic sensing system III. The fiber optic sensing system III survived in the cold flow tests in GE’s ISBF pilot test facility. However, we didn’t get high temperature data by using this system since the nanosecond laser issues. During the period of the project, test trials, data simulation and algorithm optimization was performed successfully. For real time temperature field construction, the sampling rate must be fast enough to capture the field variations. The technology of Code-division multiple access (CDMA) is well studied which could allow parallel multiplexing, even if signals overlap in time or frequencies. Moreover, it has been known that extending the length of signal significantly improves SNR. For acoustic signals, these multiplexing techniques have also been widely used, mainly for sonar and acoustic communications. The CDMA modulation technique has been proposed and studied to guarantee high network throughput, low channel access delay and low energy consumption. We have studied the temperature field reconstruction using Gaussian Radial Basis Functions (GRBF)-based approximation approach. Reconstruction of 3D temperature field using Neural Networks with measured TOF and known propagation paths is feasible. 2D and 3D temperature field reconstruction simulation results are achieved. The milestone status is shown in Table 1. We finished milestone 1-8 and milestone 10. For milestone 9, we did three pilot tests by using the fiber optic sensing system III (Distributed Sensing System II) at GE Power. However, due to the failure of the ns laser, we did not get the temperature results. We conducted some additional tasks that were not originally proposed: 1) We fabricated a fiber optic sensing system I and did a pilot test based on this system. 2) In the proposal, we proposed two pilot tests at GE Power. In reality, we finished at least seven pilot tests at GE Power. GE Power has made a lot of efforts for supporting the pilot tests. 3) We got a simulation results based on CDMA. In summary, most of the tasks have been accomplished. The outcome of this project removed a few barriers that hinder the achievement of the final product of the distributed sensing systems. With the successful accomplishment of this project, a prototype of the fiber optic sensing system can be fabricated to attract more interests from companies and other funding agencies.
A new concept has been developed for a high-temperature luminescence-based optical thermometer that both shows the desired temperature sensitivity in the upper temperature range of present state-of-the-art luminescence thermometers (above 1,300 C), while maintaining substantial stronger luminescence signal intensity that will allow these optical thermometers to operate in the presence of the high thermal background radiation typical of industrial applications. This objective is attained by using a Cr-doped GdAlO3 (Cr:GdAlO3) sensor with an orthorhombic perovskite structure, resulting in broadband luminescence that remains strong at high temperature due to the favorable electron energy level spacing of Cr:GdAlO3. The Cr:GdAlO3 temperature (and pressure) sensor can be incorporated into, or applied onto, a component s surface when a non-contact surface temperature measurement is desired, or alternatively, the temperature sensor can be attached to the end of a fiber-optic probe that can then be positioned at the location where the temperature measurement is desired. In the case of the fiber-optic probe, both the pulsed excitation and the luminescence emission travel through the fiber-optic light guide. In either case, a pulsed light source provides excitation of the luminescence, and the broadband luminescence emission is collected. Real-time temperature measurements are obtain ed using a least-squares fitting algorithm that determines the luminescence decay time, which has a known temperature dependence established by calibration. Due to the broad absorption and emission bands for Cr:GdAlO3, there is considerable flexibility in the choice of excitation wavelength and emission wavelength detection bands. The strategic choice of the GdAlO3 host is based on its high crystal field, phase stability, and distorted symmetry at the Cr3+ occupation sites. The use of the broadband emission for temperature sensing at high temperatures is a key feature of the invention and is novel since broadband luminescence emission normally shows severe thermal quenching. The tightly bound AlO6 octahedra in GdAlO3 results in a larger energy barrier to nonradiative decays than in other materials and therefore makes using broadband emission for temperature sensing possible at high temperatures. This approach results in a substantial increase in temperature capability. For example, the most commonly used Cr-doped crystal used for luminescence-based temperature measurements, ruby, has only been demonstrated up to 600 C, whereas the Cr:GdAlO3 optical thermometer under development has already been shown to exhibit useful luminescence up to 1,300 C. Because GdAlO3 is non-reactive and is stable in harsh, high-temperature environments, sensors composed of Cr:GdAlO3 will be very well suited for remote high-temperature measurements in engine or industrial environments where its intense high-temperature luminescence will stand out above significant thermal radiation background levels.