Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system value”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Energy Storage to Enable Electricity as a Commodity

A lack of large-scale economical storage, demand-side flexibility, and the need to instantaneously balance supply and demand cause challenges for electricity as a commodity. With typical commodities, stock from periods of high production can be stored and sold during low production, smoothing demand and supply shocks. In electricity markets, high storage costs have long outweighed benefits, negating convenience yield; no-arbitrage models do not apply, and typical hedging strategies cannot be performed due to infinite carry costs. However, the mechanics of energy trading are changing due to advancing storage technologies, more price-responsive demands, and virtual bidding in electricity markets, shaping a system where electricity storage can be valued on factors other than diurnal arbitrage. We examine the valuation of electricity storage through the lens of commodity markets to assess the impacts of large-scale storage deployment.

energy storage↗

Optimization of the hop-byte metric for effective topology aware mapping

Suitable mapping of processes to the nodes of a massively parallel machine can substantially improve communication performance by reducing network congestion. The hop-byte metric has been used as a measure of the quality of such a mapping by several recent works. Optimizing this metric is NP hard, and thus heuristics are applied. However, the heuristics proposed so far do not directly try to optimize this metric. Rather, they use some intuitive methods for reducing congestion and use the metric just to evaluate the quality of the mapping. In fact, heuristics intending to optimize other metrics too don't directly optimize for them, but, rather, use the metric to evaluate the results of the heuristic. In contrast, we pose the mapping problem with the hop-byte metric as a quadratic assignment problem and use a heuristic to directly optimize for this metric. We evaluate our approach on realistic node allocations obtained on the Kraken system at NICS. Our approach yields values for the metric that are up to 75% lower than the default mapping and 66 % lower than existing heuristics. However, the time taken to produce the mapping can be substantially more, which makes this suitable for somewhat static, though possibly irregular, communication patterns. We introduce new heuristics that reduce the time taken to be comparable to that of existing fast heuristics, while still producing mappings of higher quality than existing ones. We also use theoretical lower bounds to suggest that our mapping may be close to optimal, at least for medium sized problems. Consequently, our work can also provide insight into the tradeoff between mapping quality and time taken by other mapping heuristics.

Sudheer, C. D.↗

Optimal Control of Distributed Energy Resources using Model Predictive Control

In an isolated power system (rural microgrid), Distributed Energy Resources (DERs) such as renewable energy resources (wind, solar), energy storage and demand response can be used to complement fossil fueled generators. The uncertainty and variability due to high penetration of wind makes reliable system operations and controls challenging. In this paper, an optimal control strategy is proposed to coordinate energy storage and diesel generators to maximize wind penetration while maintaining system economics and normal operation. The problem is formulated as a multi-objective optimization problem with the goals of minimizing fuel costs and changes in power output of diesel generators, minimizing costs associated with low battery life of energy storage and maintaining system frequency at the nominal operating value. Two control modes are considered for controlling the energy storage to compensate either net load variability or wind variability. Model predictive control (MPC) is used to solve the aforementioned problem and the performance is compared to an open-loop look-ahead dispatch problem. Simulation studies using high and low wind profiles, as well as, different MPC prediction horizons demonstrate the efficacy of the closed-loop MPC in compensating for uncertainties in wind and demand.

Mayhorn, Ebony T.↗

A Novel Framework for Optimizing Ramping Capability of Hybrid Energy Storage Systems

Hybrid Energy Storage System has been widely applied in aerospace, electric vehicle, and microgrid applications. The advantages are that they include complimentary technologies with both high power and energy capabilities. HESS have the potential to be useful to the bulk power systems, for example to increase the value of energy produced by variable generation resource through enabling participation in ancillary service markets. Actualizing the benefits of HESSs requires optimizing the combined ramping capability of aggregated HESS resources. To provide quality ancillary service, source of HESSs locating at multiple sites of variable generation resource must be optimally sized and cohesively controlled. Optimizing aggregated resources can be formulated as an optimization problem. Successfully solving this problem not only requires using effective solution methods but also depends on accurately and rapidly setting the necessary parameters in the problem formula. This article proposes a novel framework with double-layer structure to solve the optimization problem of aggregating ramping capability. Program developed on the upper layer focuses on solving the optimization of aggregating ramping capability among multiple HESSs and is compatible with most existing optimization algorithms. Program on lower layer of the framework targets at optimizing the local control of a single HESS based on a thorough analytics of HESS operation strategy presented in this article. Result of local optimization is also provided to upper layer program for updating the parameters in formula of optimization problem. Real time hardware-in-the-loop test is conducted to verify the performance of the optimization framework developed. The work presented is expected to provide guidance for implementing this framework in practical operation.

Luo, Yushen↗

Bimodal Visualization of Industrial X-Ray and Neutron Computed Tomography Data

Advanced manufacturing creates increasingly complex objects with material compositions that are often difficult to characterize by a single modality. Our collaborating domain scientists are going beyond traditional methods by employing both X-ray and neutron computed tomography to obtain complementary representations expected to better resolve material boundaries. However, the use of two modalities creates its own challenges for visualization, requiring either complex adjustments of bimodal transfer functions or the need for multiple views. Together with experts in nondestructive evaluation, we designed a novel interactive bimodal visualization approach to create a combined view of the co-registered X-ray and neutron acquisitions of industrial objects. Using an automatic topological segmentation of the bivariate histogram of X-ray and neutron values as a starting point, the system provides a simple yet effective interface to easily create, explore, and adjust a bimodal visualization. Here, we propose a widget with simple brushing interactions that enables the user to quickly correct the segmented histogram results. Our semiautomated system enables domain experts to intuitively explore large bimodal datasets without the need for either advanced segmentation algorithms or knowledge of visualization techniques. We demonstrate our approach using synthetic examples, industrial phantom objects created to stress bimodal scanning techniques, and real-world objects, and we discuss expert feedback.

image segmentation↗

Biogeographic classification of streams using fish community– and trait–environment relationships

Abstract Aim Present a hybrid biogeographic and environmentally constrained clustering approach to classify ~853,000 stream reaches in the eastern United States. Examine the frequency of stream typologies in the landscape relative to anthropogenic stressors to identify potential stream conservation needs. Location Eastern United States. Methods Fish communities at 956 least‐disturbed sampling reaches were characterized using taxonomic and functional composition of native species. Environmental variables summarized within stream reaches included stream discharge, channel gradient, hydrologic regime, summer water temperature and boundaries of freshwater ecoregions. Multivariate regression trees were used to relate environmental variables to fish communities while simultaneously developing taxa‐ and trait‐specific biogeographic classifications. We then overlaid stream classifications with indices of anthropogenic disturbances to evaluate rarity and risk of complete loss of natural representation of stream types. Results Taxonomically based classes represented a combination of ecoregional boundaries and environmental gradients, whereas temperature gradients were most important in differentiating functional composition. An optimal taxonomy‐based classification contained 13 classes and explained 26.4% of community variation, and the optimal trait‐based classification contained 6 classes, explaining 25.2% of community variation. Overlaying class maps with an anthropogenic disturbance index revealed substantial variation in the severity of degradation among classes relative to their abundance in the landscape, especially rare classes (i.e., large rivers and cold headwater systems). Main conclusions We demonstrate the value of integrating local, regional and historical biogeographic factors with taxonomic and functional characteristics of freshwater biota to classify ecosystems based on mechanistic biota–environment relationships. This approach is important to addressing the challenge of developing stream classifications that reconcile the environmental drivers of community trait composition with the constraints of biogeographic regionality at large spatial scales. Furthermore, the spatially explicit and high‐resolution maps disseminated here can uniquely inform management decisions regarding anthropogenic threats to the biodiverse freshwaters of the eastern United States.

Troia, Matthew J.↗

The use of stored carbon reserves in growth of temperate tree roots and leaf buds: Analyses using radiocarbon measurements and modeling

Characterizing the use of carbon (C) reserves in trees is important for understanding regional and global C cycles, stress responses, asynchrony between photosynthetic activity and growth demand, and isotopic exchanges in studies of tree physiology and ecosystem C cycling. Using an inadvertent, whole-ecosystem radiocarbon ({sup 14}C) release in a temperate deciduous oak forest and numerical modeling, we estimated that the mean age of stored C used to grow both leaf buds and new roots is 0.7 years and about 55% of new-root growth annually comes from stored C. Therefore, the calculated mean age of C used to grow new-root tissue is {approx}0.4 years. In short, new roots contain a lot of stored C but it is young in age. Additionally, the type of structure used to model stored C input is important. Model structures that did not include storage, or that assumed stored and new C mixed well (within root or shoot tissues) before being used for root growth, did not fit the data nearly as well as when a distinct storage pool was used. Consistent with these whole-ecosystem labeling results, the mean age of C in new-root tissues determined using 'bomb-{sup 14}C' in three additional forest sites in North America and Europe (one deciduous, two coniferous) was less than 1-2 years. The effect of stored reserves on estimated ages of fine roots is unlikely to be large in most natural abundance isotope studies. However, models of root C dynamics should take stored reserves into account, particularly for pulse-labeling studies and fast-cycling roots (<1 years).

54 ENVIRONMENTAL SCIENCES↗

Guided combinatorial synthesis and automated characterization expedites the discovery of hard, electrically conductive Pt x Au 1-x films

Sputter-deposited Pt-Au thin films have been reported to develop a hard, stable, nanocrystalline structure, yet little is known about how these characteristics vary with Pt x Au 1-x composition and process conditions. Toward this end, this document describes an extensive, combinatorial Pt-Au thin film library including characterized film compositions, structure, and properties. Complemented by kinematic Monte Carlo simulations of codeposition, a broad range of Pt x Au 1-x compositions (from x ~ 0.02 to 0.93) was first established by sputtering with varied magnetron powers and gun tilt angles. Further, the produced films were subsequently interrogated using automated nanoindentation, x-ray reflectivity, x-ray diffraction, atomic force microscopy, surface profilometry, four-point probe sheet resistance techniques, and wavelength dispersive spectroscopy in order to determine how hardness, modulus, density, surface roughness, structure, and resistivity vary with film stoichiometry and process parameters. Combinatorial films displayed an assortment of properties with the hardness of some films exceeding values reported previously for this material system. High hardness, high modulus, and low resistivity were generally attained when using increased deposition energy and reduced angle-of-incidence processes. Overall, the research identified promising, new Pt x Au 1-x compositions for future study and pinpointed strategies for improved deposition.

36 MATERIALS SCIENCE↗

Clinical characterization of a proton beam continuous uniform scanning system with dose layer stacking

A proton beam delivery system on a gantry with continuous uniform scanning and dose layer stacking at the Midwest Proton Radiotherapy Institute has been commissioned and accepted for clinical use. This paper was motivated by a lack of guidance on the testing and characterization for clinical uniform scanning systems. As such, it describes how these tasks were performed with a uniform scanning beam delivery system. This paper reports the methods used and important dosimetric characteristics of radiation fields produced by the system. The commissioning data include the transverse and longitudinal dose distributions, penumbra, and absolute dose values. Using a 208 MeV cyclotron's proton beam, the system provides field sizes up to 20 and 30 cm in diameter for proton ranges in water up to 27 and 20 cm, respectively. The dose layer stacking method allows for the flexible construction of spread-out Bragg peaks with uniform modulation of up to 15 cm in water, at typical dose rates of 1-3 Gy/min. For measuring relative dose distributions, multielement ion chamber arrays, small-volume ion chambers, and radiographic films were employed. Measurements during the clinical commissioning of the system have shown that the lateral and longitudinal dose uniformity of 2.5% or better can be achieved for all clinically important field sizes and ranges. The measured transverse penumbra widths offer a slight improvement in comparison to those achieved with a double scattering beam spreading technique at the facility. Absolute dose measurements were done using calibrated ion chambers, thermoluminescent and alanine detectors. Dose intercomparisons conducted using various types of detectors traceable to a national standards laboratory indicate that the measured dosimetry data agree with each other within 5%.

43 PARTICLE ACCELERATORS↗

Static and rotational output variation of a tomotherapy unit

A simple device to check the machine output in rotational mode is described. Integral and instantaneous beam output in absolute dose can be measured and analyzed in a very simple manner. A method to correlate the results with the value obtained during the machine calibration in static beam and the reference value used by the treatment planning system for dose calculation in rotation beam is also described. Using this method and device, the daily output can be performed in rotational conditions which are closer to the treatment conditions. Measurement results using this device show differences in the beam output between static and rotational delivery which have to be considered carefully during the calibration process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In vivo dosimetry with optically stimulated luminescent dosimeters, OSLDs, compared to diodes; the effects of buildup cap thickness and fabrication material

Purpose: For external beam in vivo measurements, the dosimeter is normally placed on the patient's skin, and the dose to a point of interest inside the patient is derived from surface measurements. In order to obtain accurate and reliable measurements, which correlate with the dose values predicted by a treatment planning system, a dosimeter needs to be at a point of electronic equilibrium. This equilibrium is accomplished by adding material (buildup) above the detector. This paper examines the use of buildup caps in a clinical setting for two common detector types: OSLDs and diodes. Clinically built buildup-caps and commercially available hemispherical caps are investigated. The effects of buildup cap thickness and fabrication material on field-size correction factors, C{sub FS}, are reported, and differences between the effects of thickness and fabrication material are explained based on physical parameters. Methods: Measurements are made on solid water phantoms for 6 and 15 MV x-ray beams. Two types of dosimeters are used: OSLDs, InLight/OSL Nanodot dosimeters (Landauer, Inc., Glenwood, IL) and a P-type surface diode (Standard Imaging, Madison, WI). Buildup caps for these detectors were fabricated out of M3, a water-equivalent material, and sheet-metal stock of Al, Cu, and Pb. Also, commercially available hemispherical buildup caps made of plastic water and brass (Landauer, Inc., Glenwood, IL) were used with Nanodots. OSLDs were read with an InLight microStar reader (Landauer, Inc., Glenwood, IL). Dose calculations were carried out with the XiO treatment planning system (CMS/Elekta, Stockholm) with tissue heterogeneity corrections. Results: For OSLDs and diodes, when measurements are made with no buildup cap a change in C{sub FS} of 200% occurs for a field-size change from 3 cm x 3 cm to 30 cm x 30 cm. The change in C{sub FS} is reduced to about 4% when a buildup cap with wall thickness equal to the depth of maximum dose is used. Buildup caps with larger wall thickness do not cause further reduction in C{sub FS}. The buildup cap fabrication material has little or no effect on C{sub FS}. The perturbation to the delivered dose caused by placing a detector with a buildup cap on the surface of a patient is measured to be 4%-7%. A comparison between calculated dose and dose measured with a Nanodot and a diode for 6 and 15 MV x-rays is made. When C{sub FS} factors are carefully determined and applied to measurements made on a phantom, the differences between measured and calculated doses were found to be between {+-}1.3%. Conclusions: OSLDs and diodes with appropriate buildup caps can be used to measure dose on the surface of a patient and predict the delivered dose to depth dmax in a range of {+-}1.3% for 100 cGy. The buildup cap: can be fabricated from any material examined in this work, is best with wall thickness dmax, and causes a perturbation to the delivered dose of 4%-7% when the wall thickness is dmax. OSLDs and diodes with buildup caps can both give accurate measurements of delivered dose.

61 RADIATION PROTECTION AND DOSIMETRY↗

A real-time in vivo dosimetric verification method for high-dose rate intracavitary brachytherapy of nasopharyngeal carcinoma

Purpose: A real-time in vivo dosimetric verification method using metal-oxide-semiconductor field effect transistor (MOSFET) dosimeters has been developed for patient dosimetry in high-dose rate (HDR) intracavitary brachytherapy of nasopharyngeal carcinoma (NPC). Methods: The necessary calibration and correction factors for MOSFET measurements in {sup 192}Iridium source were determined in a water phantom. With the detector placed inside a custom-made nasopharyngeal applicator, the actual dose delivered to the tumor was measured in vivo and compared to the calculated values using a commercial brachytherapy planning system. Results: Five MOSFETs were independently calibrated with the HDR source, yielding calibration factors of 0.48 {+-} 0.007 cGy/mV. The maximum sensitivity variation was no more than 7% in the clinically relevant distance range of 1-5 cm from the source. A total of 70 in vivo measurements in 11 NPC patients demonstrated good agreement with the treatment planning. The mean differences between the planned and the actually delivered dose within a single treatment fraction were -0.1%{+-} 3.8% and -0.1%{+-} 3.7%, respectively, for right and left side assessments. The maximum dose deviation was less than 8.5%. Conclusions: In vivo measurement using the real-time MOSFET dosimetry system is possible to evaluate the actual dose to the tumor received by the patient during a treatment fraction and thus can offer another line of security to detect and prevent large errors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-423: TrueBeam Small Field Dosimetry Using Commercial Plastic Scintillation and Other Stereotactic Detectors

Purpose: To perform dose profile and output factor (OF) measurements with the Exradin W1 plastic scintillation detector (PSD) for small fields made by the high-definition multi-leaf collimator (MLC) on the TrueBeam STx system and to compare them to values measured with an IBA CC01 ionization chamber and a Sun Nuclear Edge detector diode for 6 MV photon beams. Methods: The Exradin W1 is a new small volume near-water equivalent and energy independent PSD manufactured by Standard Imaging, Inc. All measurements were performed in an IBA Blue Phantom water tank. Square MLC-shaped fields with sides ranging from 0.5 cm to 2 cm and jawshaped fields with sides ranging from 1 cm to 40 cm were measured using an SAD setup at 10 cm depth. Dose profile and percent depth dose (PDD) measurements were also taken under the same conditions for MLC fields 0.5×0.5 and 1×1 cm2 in size with jaws at 2×2cm2. The CC01 and W1 were vertically mounted. Results: OFs measured with the W1 for jaw only square fields were consistent with the ones measured with a Farmers PTW TN33013 ion chamber (1.8% maximum deviation). OF and penumbra measurement results are presented below. PDDs measured for all detectors are within 1.5% for the 0.5×0.5 cm2 and within 1% for the 1×1 cm2 MLC fields.Output factors:MLC size W1 CC01 EDGE0.5cm 0.555 0.541 0.5851.0cm 0.716 0.702 0.7331.5cm 0.779 0.761 0.7772.0cm 0.804 0.785 0.796Penumbras (mm):MLC size W1 CC01 EDGE0.5cm 2.7 2.9 2.51.0cm 3.0 3.4 2. Conclusion: OFs measured for small MLC fields were consistent with the ones measured with the other stereotactic detectors. Measured penumbras are consistent with detector size. The Exradin W1 PSD is an excellent choice for characterizing MLC-shaped small beam dosimetry used for stereotactic radiosurgery and body radiation therapy. Sam Beddar would like to disclose a NIH/NCI SBIR Phase II grant (2R44CA153824-02A1) with Standard Imaging, Title: “Water-Equivalent Plastic Scintillation Detectors for Small Field Radiotherapy”.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-BRE-13: Replacing Pre-Treatment Phantom QA with 3D In-Vivo Portal Dosimetry for IMRT Breast Cancer

Purpose: Pre-treatment QA of individual treatment plans requires costly linac time and physics effort. Starting with IMRT breast treatments, we aim to replace pre-treatment QA with in-vivo portal dosimetry. Methods: Our IMRT breast cancer plans are routinely measured using the ArcCheck device (SunNuclear). 2D-Gamma analysis is performed with 3%/3mm criteria and the percentage of points with gamma<1 (nG1) is calculated within the 50% isodose surface. Following AAPM recommendations, plans with nG1<90% are approved; others need further inspection and might be rejected. For this study, we used invivo portal dosimetry (IPD) to measure the 3D back-projected dose of the first three fractions for IMRT breast plans. Patient setup was online corrected before for all measured fractions. To reduce patient related uncertainties, the three IPD results were averaged and 3D-gamma analysis was applied with abovementioned criteria . For a subset of patients, phantom portal dosimetry (PPD) was also performed on a slab phantom. Results: Forty consecutive breast patients with plans that fitted the EPID were analysed. The average difference between planned and IPD dose in the reference point was −0.7+/−1.6% (1SD). Variation in nG1 between the 3 invivo fractions was about 6% (1SD). The average nG1 for IPD was 89+/−6%, worse than ArcCheck (95+/−3%). This can be explained by patient related factors such as changes in anatomy and/or model deficiencies due to e.g. inhomogeneities. For the 20 cases with PPD, mean nG1 was equal to ArcCheck values, which indicates that the two systems are equally accurate. These data therefore suggest that proper criteria for 3D invivo verification of breast treatments should be nG1>80% instead of nG1>90%, which, for our breast cases, would result in 5% (2/40) further inspections. Conclusion: First-fraction in-vivo portal dosimetry using new gamma-evaluation criteria will replace phantom measurements in our institution, saving resources and yielding 3D dosimetry of the actual patient treatment.

60 APPLIED LIFE SCIENCES↗

Accuracy and calibration of integrated radiation output indicators in diagnostic radiology: A report of the AAPM Imaging Physics Committee Task Group 190

Due to the proliferation of disciplines employing fluoroscopy as their primary imaging tool and the prolonged extensive use of fluoroscopy in interventional and cardiovascular angiography procedures, “dose-area-product” (DAP) meters were installed to monitor and record the radiation dose delivered to patients. In some cases, the radiation dose or the output value is calculated, rather than measured, using the pertinent radiological parameters and geometrical information. The AAPM Task Group 190 (TG-190) was established to evaluate the accuracy of the DAP meter in 2008. Since then, the term “DAP-meter” has been revised to air kerma-area product (KAP) meter. The charge of TG 190 (Accuracy and Calibration of Integrated Radiation Output Indicators in Diagnostic Radiology) has also been realigned to investigate the “Accuracy and Calibration of Integrated Radiation Output Indicators” which is reflected in the title of the task group, to include situations where the KAP may be acquired with or without the presence of a physical “meter.” To accomplish this goal, validation test protocols were developed to compare the displayed radiation output value to an external measurement. These test protocols were applied to a number of clinical systems to collect information on the accuracy of dose display values in the field.

60 APPLIED LIFE SCIENCES↗

SU-F-J-47: Inherent Uncertainty in the Positional Shifts Determined by a Volumetric Cone Beam Imaging System

Purpose: To quantify inherent uncertainty associated with a volumetric imaging system in its determination of positional shifts. Methods: The study was performed on an Elekta Axesse™ linac’s XVI cone beam computed tomography (CBCT) system. A CT image data set of a Penta- Guide phantom was used as reference image by placing isocenter at the center of the phantom.The phantom was placed arbitrarily on the couch close to isocenter and CBCT images were obtained. The CBCT dataset was matched with the reference image using XVI software and the shifts were determined in 6-dimensions. Without moving the phantom, this process was repeated 20 times consecutively within 30 minutes on a single day. Mean shifts and their standard deviations in all 6-dimensions were determined for all the 20 instances of imaging. For any given day, the first set of shifts obtained was kept as reference and the deviations of the subsequent 19 sets from the reference set were scored. Mean differences and their standard deviations were determined. In this way, data were obtained for 30 consecutive working days. Results: Tabulating the mean deviations and their standard deviations observed on each day for the 30 measurement days, systematic and random errors in the determination of shifts by XVI software were calculated. The systematic errors were found to be 0.03, 0.04 and 0.03 mm while random errors were 0.05, 0.06 and 0.06 mm in lateral, craniocaudal and anterio-posterior directions respectively. For rotational shifts, the systematic errors were 0.02°, 0.03° and 0.03° and random errors were 0.06°, 0.05° and 0.05° in pitch, roll and yaw directions respectively. Conclusion: The inherent uncertainties in every image guidance system should be assessed and baseline values established at the time of its commissioning. These shall be periodically tested as part of the QA protocol.

60 APPLIED LIFE SCIENCES↗

Mutual Synchronization of Nanooscillators Coupled by Spin Waves

The dynamic behavior of a system of two spin-wave-coupled nanooscillators with various values of coupling strength and frequency mismatch has been analyzed. The parameter space of the system has been divided into the regions of existence of synchronous and quasi-synchronous regimes, beats, and the regime of oscillation suppression. The regions of multistable behavior have been identified. The behavior at the boundaries of capture and retention regions has been studied. Dependences of the width of capture and retention bands on the strength of nanooscillator coupling have been obtained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Feedback control design for non-inductively sustained scenarios in NSTX-U using TRANSP

This paper examines a method for real-time control of non-inductively sustained scenarios in NSTX-U by using TRANSP,a time-dependent integrated modeling code for prediction and interpretive analysis of tokamak experimental data, as asimulator. The actuators considered for control in this work are the six neutral beam sources and the plasma boundaryshape. To understand the response of the plasma current, stored energy, and central safety factor to these actuatorsand to enable systematic design of control algorithms, simulations were run in which the actuators were modulated anda linearized dynamic response model was generated. A multi-variable model-based control scheme that accounts for thecoupling and slow dynamics of the system while mitigating the effect of actuator limitations was designed andsimulated. Simulations show that modest changes in the outer gap and heating power can improve the response time ofthe system, reject perturbations, and track target values of the controlled values.

Predictive simulations↗