Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “soft”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Robust analysis of space-, time-, and energy-resolved soft x-ray measurements of magnetically confined fusion plasmas (invited)

A novel compact multi-energy soft x-ray (ME-SXR) diagnostic based on the PILATUS3 100K x-ray detector has been developed in collaboration between the Princeton Plasma Physics Laboratory and the University of Wisconsin-Madison and tested on the Madison Symmetric Torus (MST) reversed-field pinch. This solid-state photon-counting detector consists of a two-dimensional array of ~100 000 pixels for which the lower photon absorption cutoff energy can be independently set, allowing it to be configured for a unique combination of simultaneous spatial, spectral, and temporal resolution of ~1 cm, 100 eV, and 500 Hz, respectively. The diagnostic is highly versatile and can be readily adapted to diverse plasma operating conditions and scientific needs without any required downtime. New results from improved-confinement and quasi-single helicity plasmas in the MST demonstrate how the detector can be applied to study multiple aspects of the evolution of magnetically confined fusion-grade plasmas. These include observing the evolution of thermal emissivity, characterizing the energy of mid-Z excitation lines, extracting the T e profile, and observing the evolution of non-thermal populations. A technique for integrating the ME-SXR diagnostic into an integrated data analysis framework based on Bayesian inference is also presented. As a result, this allows ME-SXR measurements to be combined with data for complementary diagnostics in order to simultaneously infer Te and nZ from all available information.

47 OTHER INSTRUMENTATION↗

The influence of surface impurities on photoelectric currents driven by intense soft x rays

In an x-ray driven cavity experiment, an intense flux of soft x rays on the emitting surface produces significant emission of photoelectrons having several kiloelectronvolts of kinetic energy. At the same time, rapid heating of the emitting surface occurs, resulting in the release of adsorbed surface impurities and subsequent formation of an impurity plasma. This numerical study explores a simple model for the photoelectric currents and the impurity plasma. In this work, attention is given to the effect of varying the composition of the impurity plasma. The presence of protons or hydrogen molecular ions leads to a substantially enhanced cavity current, while heavier plasma ions are seen to have a limited effect on the cavity current due to their lower mobility. Additionally, it is demonstrated that an additional peak in the current waveform can appear due to the impurity plasma. A correlation between the impurity plasma composition and the timing of this peak is elucidated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sub-keV design for the National Ignition Facility’s soft x-ray Opacity Spectrometer (OpSpec) and expansion plans for time-resolved measurements

When compared with the National Ignition Facility’s (NIF) original soft x-ray opacity spectrometer, which used a convex cylindrical design, an elliptically shaped design has helped to increase the signal-to-noise ratio and eliminated nearly all reflections from alternate crystal planes. The success of the elliptical geometry in the opacity experiments has driven a new elliptical geometry crystal with a spectral range covering 520–1100 eV. When coupled with the primary elliptical geometry, which spans 1000–2100 eV, the new sub-keV elliptical geometry helps to cover the full iron L-shell and major oxygen transitions important to solar opacity experimentation. The new design has been built and tested by using a Henke x-ray source and shows the desired spectral coverage. Additional plans are underway to expand these opacity measurements into a mode of time-resolved detection, ~1 ns gated, but considerations for the detector size and photometrics mean a crystal geometry redesign. Here, the new low-energy geometry, including preliminary results from the NIF opacity experiments, is presented along with the expansion plans into a time-resolved platform.

47 OTHER INSTRUMENTATION↗

Tangential extreme ultraviolet and soft x-ray diagnostic system for time-resolved temperature measurement on the High Beta Tokamak-Extended Pulse

The High Beta Tokamak-Extended Pulse has recently incorporated a tangential multi-energy extreme ultraviolet and soft x-ray diagnostic system. This system enables measurements of the electron temperature and the examination of mode dynamics within the tokamak. While other systems have been built for poloidal views over similar temperature ranges, this is the first multi-energy tangential-view system designed to work in a temperature range below 200 eV in a tokamak. To facilitate these measurements, a filter wheel comprising five distinct groups of dual-filters has been developed and implemented. By employing a combination of 0.1 μm aluminum and 0.2 μm titanium filters, the system allows estimation of electron temperature profiles through reconstruction of the emission profile using the standard “double-foil” technique. The influence of impurities and filter oxide layers on measurement outcomes is examined. Results reveal that, while the absolute electron temperature values may exhibit some deviations, key characteristics like the electron temperature profile shape and inversion radius during sawtooth events remain consistent. This consistency confirms the system’s suitability for core plasma studies. This system has proven effective in detecting and analyzing internal magnetohydrodynamic phenomena, such as sawteeth.

Instruments & Instrumentation↗

Testing the optical components for the National Ignition Facility time-resolved soft x-ray opacity spectrometer (OpSpecTR)

Opacity measurements are being carried out at the Z-facility at Sandia National Laboratories and at the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory. The current soft x-ray Opacity Spectrometer (OpSpec) used on the NIF uses two elliptically bent crystals in time-integrated mode on either an image plate or a film. Plans are under way to expand these opacity measurements into a mode of time-resolved detection, called OpSpecTR. Previously, considerations for the available hCMOS detector size and photometrics led to a crystal geometry redesign and the use of a grazing angle x-ray mirror. The mirror acts as a low-pass x-ray energy filter, reducing the contribution of higher energy x rays. The first tests of the mirror and the crystal for OpSpecTR are presented here. The size of the mirror reflection and the reflectivity is tested using a Manson x-ray source. The mirror coupled with the new elliptical crystal shape demonstrates OpSpecTR’s spectral coverage. Finally, the results from the x-ray optics performance testing are shown along with the intended design.

47 OTHER INSTRUMENTATION↗

Introducing new resonant soft x-ray scattering capability in SSRL

Resonant soft x-ray scattering (RSXS) is a powerful technique for probing both spatial and electronic structures within solid-state systems. Here, we present a newly developed RSXS capability at beamline 13-3 of the Stanford Synchrotron Radiation Lightsource, designed to enhance materials science research. This advanced setup achieves a base sample temperature as low as 9.8 K combined with extensive angular motions (azimuthal ϕ and flipping χ), enabling comprehensive exploration of reciprocal space. Two types of detectors—an Au/GaAsP Schottky photodiode and a charge-coupled device detector with over 95% quantum efficiency—are integrated to effectively capture scattered photons. Extensive testing has confirmed the enhanced functionality of this RSXS setup, including its temperature and angular performance. The versatility and effectiveness of the system have been demonstrated through studies of various materials, including superlattice heterostructures and high-temperature superconductors.

Kuo, Cheng-Tai [SLAC National Accelerator Laborato↗

Wet chemistry-synthesized Fe/mixed ferrite soft magnetic composites for high-frequency power conversion

State-of-the-art soft magnetic (SM) alloy systems such as electrical steels and permalloys exhibit large eddy current losses at high-frequency (kHz range and above), limiting their application in fast switching devices. Eddy current losses can be reduced for metallic alloys through a decrease in characteristic length scale or embedding them in an insulation layer. This work proposes the development of fine-scale core materials consisting of metallic SM nano/microparticles with magnetic, inorganic insulation layers, and their synthesis using a wet chemistry-based, scalable method for high frequency and high-power applications. More specifically, a magnetic ferrite coating (Ni 0.5-x Mn x Zn 0.5 Fe 2 O 4 , x = 0.0–0.5) was applied via deposition of ferrite powder produced using a “wet chemistry-based” co-precipitation method; the ferrite was distributed through the Fe micropowder via either ball milling or ultrasonic mixing. Powder cores were prepared by compaction of the synthesized composites. Relative magnetic permeability and core loss were measured at excitation frequencies to 200 kHz. A core loss of 127 kW/m 3 was measured at excitation frequency of 100 kHz and magnetization of 0.02 T. This value improves on the 199.3 kW/m 3 reported in literature at identical excitation conditions for a compact formed from a composite comprising Fe microparticles coated with low-permeability Ni 0.5 Zn 0.5 Fe 2 O 4 . Ultrasonic mixing resulted in slightly lower core loss than ball milling, possibly because ball milling causes loss-increasing deformation of the Fe micropowder. XRD and SEM were used to observe composite composition and core cross-section microstructure.

36 MATERIALS SCIENCE↗

Simple receiver with soft decision forward error correction for binary amplitude modulation

A simple receiver with soft decision forward error correction (FEC) based on two comparators is proposed. It is shown that the gain in the optical signal-to-noise ratio (OSNR), as compared with conventional receivers with hard decision FEC, can reach 0.5 dB. Some design variants of such detectors are presented. (laser applications and other topics in quantum electronics)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Coherent X-ray diffraction from collagenous soft tissues

Coherent X-ray diffraction has been applied in the imaging of inorganic materials with great success. However, its application to biological specimens has been limited to some notable exceptions, due to the induced radiation damage and the extended nature of biological samples, the last limiting the application of most part of the phasing algorithms. X-ray ptychography, still under development, is a good candidate to overcome such difficulties and become a powerful imaging method for biology. We describe herein the feasibility of applying ptychography to the imaging of biological specimens, in particular collagen rich samples. We report here speckles in diffraction patterns from soft animal tissue, obtained with an optimized small angle X-ray setup that exploits the natural coherence of the beam. By phasing these patterns, dark field images of collagen within tendon, skin, bone, or cornea will eventually be obtained with a resolution of 60-70 nm. We present simulations of the contrast mechanism in collagen based on atomic force microscope images of the samples. Simulations confirmed the 'speckled' nature of the obtained diffraction patterns. Once inverted, the patterns will show the disposition and orientation of the fibers within the tissue, by enhancing the phase contrast between protein and no protein regions of the sample. Our work affords the application of the most innovative coherent X-ray diffraction tools to the study of biological specimens, and this approach will have a significant impact in biology and medicine because it overcomes many of the limits of current microscopy techniques.

59 BASIC BIOLOGICAL SCIENCES↗

Binary nanoparticle superlattices of soft-particle systems

Significance The phase diagram of a system of two species of particles with different diameters interacting with a soft ( 1 / r 12 ) potential is provided. The results provide a general framework to predict the crystalline phases observed in nanoparticle superlattices. The approach is particularly relevant for nanoparticles with hydrocarbon capping ligands where theoretical descriptions have been based on hard-sphere systems and is general enough to consider supercrystals obtained by DNA programmable self-assembly, thus providing a conceptual unification for general nanoparticle superlattice systems.

36 MATERIALS SCIENCE↗

Elucidating the G″ overshoot in soft materials with a yield transition via a time-resolved experimental strain decomposition

Significance The yielding transition in soft materials manifests macroscopically as a reversible transition from solid-like deformation to liquid-like flow under sufficiently large loading or deformation. Despite the ubiquity of materials that exhibit yielding, an understanding of the transition has remained elusive due to experimental limitations of the simple rheological tests typically used to study it. We present here a more thorough understanding of yielding, obtained via an iterative test protocol and analysis that allow for the separation of solid-like and liquid-like behaviors in the response of these materials. We show that yielding is a gradual transition, occurring to an increased extent as the deformation increases.

Donley, Gavin J.↗

Transport coefficient approach for characterizing nonequilibrium dynamics in soft matter

Nonequilibrium states in soft condensed matter require a systematic approach to characterize and model materials, enhancing predictability and applications. Among the tools, X-ray photon correlation spectroscopy (XPCS) provides exceptional temporal and spatial resolution to extract dynamic insight into the properties of the material. However, existing models might overlook intricate details. We introduce an approach for extracting the transport coefficient, denoted as $J(t)$, from the XPCS studies. This coefficient is a fundamental parameter in nonequilibrium statistical mechanics and is crucial for characterizing transport processes within a system. Our method unifies the Green–Kubo formulas associated with various transport coefficients, including gradient flows, particle–particle interactions, friction matrices, and continuous noise. We achieve this by integrating the collective influence of random and systematic forces acting on the particles within the framework of a Markov chain. We initially validated this method using molecular dynamics simulations of a system subjected to changes in temperatures over time. Subsequently, we conducted further verification using experimental systems reported in the literature and known for their complex nonequilibrium characteristics. The results, including the derived $J(t)$ and other relevant physical parameters, align with the previous observations and reveal detailed dynamical information in nonequilibrium states. This approach represents an advancement in XPCS analysis, addressing the growing demand to extract intricate nonequilibrium dynamics. Further, the methods presented are agnostic to the nature of the material system and can be potentially expanded to hard condensed matter systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Three-dimensional high-content imaging of unstained soft tissue with subcellular resolution using a laboratory-based X-ray microscope

With increasing interest in studying biological systems across spatial scales—from centimeters down to nanometers—histology continues to be the gold standard for tissue imaging at cellular resolution, providing an essential bridge between macroscopic and nanoscopic analysis. However, its inherently destructive and two-dimensional nature limits its ability to capture the full three-dimensional complexity of tissue architecture. Here, we show that phase-contrast X-ray microscopy can enable three-dimensional virtual histology with subcellular resolution. This technique provides direct quantification of electron density without restrictive assumptions, allowing for direct characterization of cellular nuclei in a standard laboratory setting. By combining high spatial resolution and soft tissue contrast, with automated segmentation of cell nuclei, we demonstrated virtual Hematoxylin and Eosin (H&E) staining using machine learning-based style transfer, yielding volumetric datasets compatible with existing histopathological analysis tools. Furthermore, by integrating electron density and the sensitivity to nanometric features of the dark field contrast channel, we achieve stain-free, high-content imaging capable of distinguishing nuclei and extracellular matrix.

3D virtual histology↗

An investigation of aqueous ammonium nitrate aerosols with soft X-ray spectroscopy

Aqueous aerosols are important in atmospheric chemistry, drug delivery, and human health. X-ray photoelectron spectroscopy (XPS), a surface-sensitive technique and near-edge X-ray absorption fine structure (NEXAFS) spectroscopy which informs on the bulk, is deployed to study the solvation of ammonium nitrate (NH 4 NO 3 ). Aerosolised solutions of NH 4 NO 3 were introduced into a photoelectron spectrometer via an aerodynamic lens, and interrogated with soft X-ray photons, the resulting electrons were imaged via velocity map imaging. Density functional theory calculations were performed to compare with the measured binding energies of NH 4 + and NO 3 - solvated in water. The results reveal that the nitrate anion has a slight propensity for the surface, while both ammonium and nitrate ions are present in equal measure in the bulk.

74 ATOMIC AND MOLECULAR PHYSICS↗

Design Studies for a VUV--Soft X-ray Free-Electron Laser Array

Several recent reports have identified the scientific requirements for a future soft X-ray light source [1, 2, 3, 4, 5], and a high-repetition-rate free-electron laser (FEL) facility responsive to them is being studied at Lawrence Berkeley National Laboratory (LBNL) [6]. The facility is based on a continuous-wave (CW) superconducting linear accelerator with beam supplied by a high-brightness, high-repetition-rate photocathode electron gun operating in CW mode, and on an array of FELs to which the accelerated beam is distributed, each operating at high repetition rate and with even pulse spacing. Dependent on the experimental requirements, the individualFELs may be configured for either self-amplified spontaneous emission (SASE), seeded highgain harmonic generation (HGHG), echo-enabled harmonic generation (EEHG), or oscillator mode of operation, and will produce high peak and average brightness x-rays with a flexible pulse format ranging from sub-femtoseconds to hundreds of femtoseconds. This new light source would serve a broad community of scientists in many areas of research, similar to existing utilization of storage ring based light sources. To reduce technical risks and constructioncosts, accelerator research, development, and design studies at LBNL target the most critical components and systems of the facility. We are developing a high-repetition-rate low-emittance electron gun, high quantum efficiency photocathodes, and have embarked on design and optimization of the electron beam accelerator, FEL switchyard, and array of FELs. We continue our work on precision timing and synchronization systems critical for time-resolved experiments using pump-probe techniques.

43 PARTICLE ACCELERATORS↗

ON THE DOUBLE NATURED SOLUTIONS OF THE TWO-TEMPERATURE EXTERNAL SOFT PHOTON COMPTONIZED ACCRETION DISKS

We have analyzed pair production in the innermost region of a two-temperature external soft photon Comptonized accretion disk. We have shown that, if the viscosity parameter is greater than a critical value {alpha}{sub c}, the solution to the disk equation is double valued: one, advection dominated, and the other, radiation dominated. When {alpha} {<=} {alpha}{sub c}, the accretion rate has to satisfy m-dot{sub 1}{<=}m-dot{<=}m-dot{sub c} in order to have two steady-state solutions. It is shown that these critical parameters m-dot{sub 1}, m-dot{sub c} are functions of r, {alpha}, and {theta}{sub e}, and {alpha}{sub c} is a function of r and {theta}{sub e}. Depending on the combination of the parameters, the advection-dominated solution may not be physically consistent. It is also shown that the electronic temperature is maximum at the onset of the thermal instability, from which results this inner region. These solutions are stable against perturbations in the electron temperature and in the density of pairs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

ON THE EVOLUTION OF ANOMALOUS X-RAY PULSARS AND SOFT GAMMA-RAY REPEATERS WITH FALL BACK DISKS

We show that the period clustering of anomalous X-ray pulsars (AXPs) and soft gamma-ray repeaters (SGRs), their X-ray luminosities, ages, and statistics can be explained with fall back disks with large initial specific angular momentum. The disk evolution models are developed by comparison to self-similar analytical models. The initial disk mass and angular momentum set the viscous timescale. An efficient torque, with (1 - {omega}{sup 2}{sub *}) dependence on the fastness parameter {omega}{sub *}, leads to period clustering in the observed AXP-SGR period range under a wide range of initial conditions. The timescale t{sub 0} for the early evolution of the fall back disk, and the final stages of fall back disk evolution, when the disk becomes passive, are the crucial determinants of the evolution. The disk becomes passive at temperatures around 100 K, which provides a natural cutoff for the X-ray luminosity and defines the end of evolution in the observable AXP and SGR phase. This low value for the minimum temperature for active disk turbulence indicates that the fall back disks are active up to a large radius, {approx}>10{sup 12} cm. We find that transient AXPs and SGRs are likely to be older than their persistent cousins. A fall back disk with mass transfer rates corresponding to the low quiescent X-ray luminosities of the transient sources in early evolutionary phases would have a relatively lower initial mass, such that the mass-flow rate in the disk is not sufficient for the inner disk to penetrate into the light cylinder of the young neutron star, making mass accretion onto the neutron star impossible. The transient AXP phase therefore must start later. The model results imply that the transient AXP/SGRs, although older, are likely to be similar in number to persistent sources. This is because the X-ray luminosities of AXPs and SGRs are found to decrease faster at the end of their evolution, and the X-ray luminosities of transient AXP and SGRs in quiescence lie in the luminosity range of X-ray cutoff phase. Taking the range of quiescent X-ray luminosities of transient AXPs and SGRs {approx}10{sup 33}-10{sup 34} erg s{sup -1}, our simulations imply that the duration of the cutoff phase is comparable to the lifetime in the persistent phase for a large range of initial conditions.

79 ASTRONOMY AND ASTROPHYSICS↗

MAGNETIC DOMAINS IN MAGNETAR MATTER AS AN ENGINE FOR SOFT GAMMA-RAY REPEATERS AND ANOMALOUS X-RAY PULSARS

Magnetars have been suggested as the most promising site for the origin of observed soft gamma-ray repeaters (SGRs) and anomalous X-ray pulsars (AXPs). In this work, we investigate the possibility that SGRs and AXPs might be observational evidence for a magnetic phase separation in magnetars. We study magnetic domain formation as a new mechanism for SGRs and AXPs in which magnetar matter separates into phases containing different flux densities. We identify the parameter space in matter density and magnetic field strength at which there is an instability for magnetic domain formation. We conclude that such instabilities will likely occur in the deep outer crust for the magnetic Baym, Pethick, and Sutherland model and in the inner crust and core for magnetars described in the relativistic Hartree theory. Moreover, we estimate that the energy released by the onset of this instability is comparable with the energy emitted by SGRs.

79 ASTRONOMY AND ASTROPHYSICS↗