Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “simulation tools”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Fast and scalable quantum Monte Carlo simulations of electron-phonon models

We introduce methodologies for highly scalable quantum Monte Carlo simulations of electron-phonon models, and report benchmark results for the Holstein model on the square lattice. The determinant quantum Monte Carlo (DQMC) method is a widely used tool for simulating simple electron-phonon models at finite temperatures, but incurs a computational cost that scales cubically with system size. Alternatively, near-linear scaling with system size can be achieved with the hybrid Monte Carlo (HMC) method and an integral representation of the Fermion determinant. Here, we introduce a collection of methodologies that make such simulations even faster. To combat "stiffness" arising from the bosonic action, we review how Fourier acceleration can be combined with time-step splitting. To overcome phonon sampling barriers associated with strongly-bound bipolaron formation, we design global Monte Carlo updates that approximately respect particle-hole symmetry. To accelerate the iterative linear solver, we introduce a preconditioner that becomes exact in the adiabatic limit of infinite atomic mass. Finally, we demonstrate how stochastic measurements can be accelerated using fast Fourier transforms. Here, these methods are all complementary and, combined, may produce multiple orders of magnitude speedup, depending on model details.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

FESTIV (Flexible Energy Scheduling Tool for Integrating Variable generation) [SWR-14-11]

Flexible Energy Scheduling Tool for Integrating Variable generation (FESTIV) is a tool that simulates the realistic representation of steady-state power system operations and scheduling performed by an independent system operator, regional transmission organization, or a vertically integrated regulated utility. The tool integrates security-constrained unit commitment (SCUC), security-constrained economic dispatch (SCED), and automatic generation control (AGC) into one model. These are the three modes of power system scheduling that are used to meet the changing net demand. Each of these submodels have different time characteristics and are used to meet the changing demand at different time resolutions and horizons. This allows multiple timescales to be studied where FESTIV accounts for intertemporal coupling between each submodel and the submodels themselves. It does this while having different objectives between the submodels; commitment of resources, dispatch and reserve commitment, and finally control.

Ela, Erik↗

SU-E-T-524: In-Vivo Diode Dosimetry Proton Therapy Range Verification Validation Study for Pediatric CSI

Purpose: With the aim of reducing acute esophageal radiation toxicity in pediatric patients receiving craniospinal irradiation (CSI), we investigated the implementation of an in-vivo, adaptive proton therapy range verification methodology. Simulation experiments and in-phantom measurements were conducted to validate the range verification technique for this clinical application. Methods: A silicon diode array system has been developed and experimentally tested in phantom for passively scattered proton beam range verification for a prostate treatment case by correlating properties of the detector signal to the water equivalent path length (WEPL). We propose to extend the methodology to verify range distal to the vertebral body for pediatric CSI cases by placing this small volume dosimeter in the esophagus of the anesthetized patient immediately prior to treatment. A set of calibration measurements was performed to establish a time signal to WEPL fit for a “scout” beam in a solid water phantom. Measurements are compared against Monte Carlo simulation in GEANT4 using the Tool for Particle Simulation (TOPAS). Results: Measurements with the diode array in a spread out Bragg peak of 14 cm modulation width and 15 cm range (177 MeV passively scattered beam) in solid water were successfully validated against proton fluence rate simulations in TOPAS. The resulting calibration curve allows for a sensitivity analysis of detector system response with dose rate in simulation and with individual diode position through simulation on patient CT data. Conclusion: Feasibility has been shown for the application of this range verification methodology to pediatric CSI. An in-vivo measurement to determine the WEPL to the inner surface of the esophagus will allow for personalized adjustment of the treatment plan to ensure sparing of the esophagus while confirming target coverage. A Toltz acknowledges partial support by the CREATE Medical Physics Research Training Network grant of the Natural Sciences and Engineering Research Council (Grant number: 432290)

60 APPLIED LIFE SCIENCES↗

Gold nanoparticle induced vasculature damage in radiotherapy: Comparing protons, megavoltage photons, and kilovoltage photons

Purpose: The purpose of this work is to investigate the radiosensitizing effect of gold nanoparticle (GNP) induced vasculature damage for proton, megavoltage (MV) photon, and kilovoltage (kV) photon irradiation. Methods: Monte Carlo simulations were carried out using tool for particle simulation (TOPAS) to obtain the spatial dose distribution in close proximity up to 20 μm from the GNPs. The spatial dose distribution from GNPs was used as an input to calculate the dose deposited to the blood vessels. GNP induced vasculature damage was evaluated for three particle sources (a clinical spread out Bragg peak proton beam, a 6 MV photon beam, and two kV photon beams). For each particle source, various depths in tissue, GNP sizes (2, 10, and 20 nm diameter), and vessel diameters (8, 14, and 20 μm) were investigated. Two GNP distributions in lumen were considered, either homogeneously distributed in the vessel or attached to the inner wall of the vessel. Doses of 30 Gy and 2 Gy were considered, representing typical in vivo enhancement studies and conventional clinical fractionation, respectively. Results: These simulations showed that for 20 Au-mg/g GNP blood concentration homogeneously distributed in the vessel, the additional dose at the inner vascular wall encircling the lumen was 43% of the prescribed dose at the depth of treatment for the 250 kVp photon source, 1% for the 6 MV photon source, and 0.1% for the proton beam. For kV photons, GNPs caused 15% more dose in the vascular wall for 150 kVp source than for 250 kVp. For 6 MV photons, GNPs caused 0.2% more dose in the vascular wall at 20 cm depth in water as compared to at depth of maximum dose (Dmax). For proton therapy, GNPs caused the same dose in the vascular wall for all depths across the spread out Bragg peak with 12.7 cm range and 7 cm modulation. For the same weight of GNPs in the vessel, 2 nm diameter GNPs caused three times more damage to the vessel than 20 nm diameter GNPs. When the GNPs were attached to the inner vascular wall, the damage to the inner vascular wall can be up to 207% of the prescribed dose for the 250 kVp photon source, 4% for the 6 MV photon source, and 2% for the proton beam. Even though the average dose increase from the proton beam and MV photon beam was not large, there were high dose spikes that elevate the local dose of the parts of the blood vessel to be higher than 15 Gy even for 2 Gy prescribed dose, especially when the GNPs can be actively targeted to the endothelial cells. Conclusions: GNPs can potentially be used to enhance radiation therapy by causing vasculature damage through high dose spikes caused by the addition of GNPs especially for hypofractionated treatment. If GNPs are designed to actively accumulate at the tumor vasculature walls, vasculature damage can be increased significantly. The largest enhancement is seen using kilovoltage photons due to the photoelectric effect. Although no significant average dose enhancement was observed for the whole vasculature structure for both MV photons and protons, they can cause high local dose escalation (>15 Gy) to areas of the blood vessel that can potentially contribute to the disruption of the functionality of the blood vessels in the tumor.

60 APPLIED LIFE SCIENCES↗

Open-Datasets for WEC Simulation

SAND2025-11468O The Open-Datasets for WEC Simulation is a tool that uses datasets and simulation configuration files to conduct OpenFOAM wave energy converter (WEC) simulations. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Chartrand, Chris [Sandia National Lab. (SNL-CA), L↗

US-UK fusion energy collaborations in the digital space

The US and UK share the vision for fusion as a vital part of the clean energy future. This vision is reflected in the respective national plans in the form of the Bold Decadal Vision for Commercial Fusion (BDV) in the US and the Spherical Tokamak for Energy Production (STEP) program in the UK. Digital tools such as simulation and control frameworks, design tools, AI/ML, high performance computing (HPC), and virtual reality (VR) will play an important role in developing, diagnosing, operating, and further improving burning-plasma-class fusion power plants. Therefore, a collaborative approach, involving both the public and private sectors, to developing these digital tools can accelerate the path to fusion energy commercialization. In this report we discuss previous and ongoing collaborations and opportunities to expand these collaborations into new areas. We conclude this report with near term actions and a vision of the collaboration to the Joint Coordinating Committee.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of a Novel Oscillating Surge Wave Energy Converter: Preprint

This study investigates the performance of an oscillating surge wave energy converter (OSWEC) that utilizes adjustable geometry as a means of controlling the hydrodynamic coefficients, a concept originally proposed by [1]. The body of the device consists of a bottom-hinged solid rectangular frame with five horizontal flaps spanning the interior of the frame. The flaps can rotate independently about their center of rotation within the frame like a large window shutter. Changing the orientation of the flaps alters the hydrodynamic coefficients and natural frequency of the device as well as the ability to shed or absorb structural loads accordingly. This ability may allow the device to operate in a wider range of sea states than other current wave energy converter designs. This paper presents and compares the results of numerical simulations and experimental testing of the OSWEC's response to regular waves with all five of the horizontal fin configurations sharing the same orientation of 0 degrees (fully closed interior) and 90 degrees (fully open). The numerical simulations were performed using WAMIT, which calculates hydrodynamic coefficients using a boundary element method code to solve the linear potential flow problem, and WEC-Sim, a MATLAB-based tool that simulates multibody devices in the time domain by solving the governing equations of motion. A 1:14 scale model of the device was built for experimental evaluation in an 8-m-long, 1-m wide wave tank, which supports a water depth of 0.7 m. The OSWEC motion in different wave conditions was measured with displacement sensors while nonlinear wave-structure interaction effects like slamming and overtopping were captured using a high-speed camera and used to understand differences between the simulation and experiments.

13 HYDRO ENERGY↗

Benchmarking of measurement and simulation of transverse rms-emittance growth

Transverse emittance growth along the Alvarez DTL section is a major concern with respect to the preservation of beam quality of high current beams at the GSI UNILAC. In order to define measures to reduce this growth appropriated tools to simulate the beam dynamics are indispensable. This paper is about the benchmarking of three beam dynamics simulation codes, i.e. DYNAMION, PARMILA, and PARTRAN against systematic measurements of beam emittances for different machine settings. Experimental set-ups, data reduction, the preparation of the simulations, and the evaluation of the simulations will be described. It was found that the measured 100%-rmsemittances behind the DTL exceed the simulated values. Comparing measured 90%-rms-emittances to the simulated 95%-rms-emittances gives fair to good agreement instead. The sum of horizontal and vertical emittances is even described well by the codes as long as experimental 90%-rmsemittances are compared to simulated 95%-rms-emittances. Finally, the successful reduction of transverse emittance growth by systematic beam matching is reported.

43 PARTICLE ACCELERATORS↗

A Flexible Tool for Beam Induced Background Simulations at a Muon Collider

A Muon Collider represents a very interesting possibility for a future machine to explore the energy frontier in particle physics.However, to reach the needed luminosity, beam intensities of the order of $10^{9-11}$ muons per bunch are needed. In this context, the Beam Induced Background must be taken into account for its effects on the magnets and on the detector. Several optimizations can be conceived with the aim to mitigate them. In this view, it is of crucial importance to develop a flexible tool that allows to easily reconstruct the machine geometry in a Monte Carlo code, allowing to simulate in detail the interaction of muon decay products in the machine, while being able to change the machine optics itself to find the best configuration.In this contribution, a possible approach to such a purpose is presented, based on FLUKA for the Monte Carlo simulation and on LineBuilder for the geometry reconstruction.First results for the 1.5TeV machine optics developed by the MAP collaboration are discussed in this paper.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Automated Calibration for Rapid Optical Spectroscopy Sensor Development for Online Monitoring

An automated platform has been developed to assist researchers in the rapid development of optical spectroscopy sensors to quantify species from spectral data. This platform performs calibration and validation measurements simultaneously. Real-time, in situ monitoring of complex systems through optical spectroscopy has been shown to be a useful tool; however, building calibration models requires development time, which can be a limiting factor in the case of radiological or otherwise hazardous systems. While calibration time can be reduced through optimized design of experiments, this study approached the challenge differently through automation. The ATLAS (Automated Transient Learning for Applied Sensors) platform used pneumatic control of stock solutions to cycle flow profiles through desired calibration concentrations for multivariate model construction. Additionally, the transients between desired concentrations based on flow calculations were used as validation measurements to understand model predictive capabilities. This automated approach yielded an incredible 76% reduction in model development time and a 60% reduction in sample volume versus estimated manual sample preparation and static measurements. The ATLAS system was demonstrated on two systems: a three-lanthanide system with Pr/Nd/Ho representing a use case with significant overlap or interference between analyte signatures and an alternate system containing Pr/Nd/Ni to demonstrate a use case in which broad-band corrosion species signatures interfered with more distinct lanthanide absorbance profiles. Both systems resulted in strong model prediction performance (RMSEP < 9%). Lastly, ATLAS was demonstrated as a tool to simulate process monitoring scenarios (e.g., column separation) in which models can be further optimized to account for day-to-day changes as necessary (e.g., baseline correction). Ultimately, ATLAS offers a vital tool to rapidly screen monitoring methods, investigate sensor fusion, and explore more complex systems (i.e., larger numbers of species).

47 OTHER INSTRUMENTATION↗

Simulation of High-Resolution Magnetic Resonance Images on the IBM Blue Gene/L Supercomputer Using SIMRI

Medical imaging system simulators are tools that provide a means to evaluate system architecture and create artificial image sets that are appropriate for specific applications. We have modified SIMRI, a Bloch equation-based magnetic resonance image simulator, in order to successfully generate high-resolution 3D MR images of the Montreal brain phantom using Blue Gene/L systems. Results show that redistribution of the workload allows an anatomically accurate 256 3 voxel spin-echo simulation in less than 5 hours when executed on an 8192-node partition of a Blue Gene/L system.

97 MATHEMATICS AND COMPUTING↗

Axom

Axom is an open-source library of "building block" software components that provide core infrastructure capabilities for HPC applications. Such capabilities include: input file parsing and verification for various file formats, format specification for material shape input to multi-material simulations and tools for placing those shapes on meshes, parallel distributed coordination of diagnostic messages, geometric primitives, spatial queries and spatial search acceleration data structures, in memory key-value data store for managing simulation data and parallel file I/O. Axom components are used widely across LLNL Advanced Simulation and Computing program applications. It is also part of the LLNL institutionally-supported RADIUSS project, which promotes and funds its adoption by projects across LLNL.

Zagaris, George↗

An implementation of co-simulation for performance prediction of innovative integrated HVAC systems in buildings

Integrated performance simulation of buildings and heating, ventilation and air-conditioning (HVAC) systems can help reducing energy consumption and increasing level of occupant comfort. However, no singe building performance simulation (BPS) tool offers sufficient capabilities and flexibilities to accommodate the ever-increasing complexity and rapid innovations in building and system technologies. One way to alleviate this problem is to use co-simulation. The co-simulation approach represents a particular case of simulation scenario where at least two simulators solve coupled differential-algebraic systems of equations and exchange data that couples these equations during the time integration. This paper elaborates on issues important for co-simulation realization and discusses multiple possibilities to justify the particular approach implemented in a co-simulation prototype. The prototype is verified and validated against the results obtained from the traditional simulation approach. It is further used in a case study for the proof-of-concept, to demonstrate the applicability of the method and to highlight its benefits. Stability and accuracy of different coupling strategies are analyzed to give a guideline for the required coupling frequency. The paper concludes by defining requirements and recommendations for generic cosimulation implementations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Co-simulation of innovative integrated HVAC systems in buildings

Integrated performance simulation of buildings HVAC systems can help in reducing energy consumption and increasing occupant comfort. However, no single building performance simulation (BPS) tool offers sufficient capabilities and flexibilities to analyze integrated building systems and to enable rapid prototyping of innovative building and system technologies. One way to alleviate this problem is to use co-simulation, as an integrated approach to simulation. This article elaborates on issues important for co-simulation realization and discusses multiple possibilities to justify the particular approach implemented in the here described co-simulation prototype. The prototype is validated with the results obtained from the traditional simulation approach. It is further used in a proof-of-concept case study to demonstrate the applicability of the method and to highlight its benefits. Stability and accuracy of different coupling strategies are analyzed to give a guideline for the required coupling time step.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NEAMS Update: Quarterly Report for October - December 2011

The Advanced Modeling and Simulation Office within the DOE Office of Nuclear Energy (NE) has been charged with revolutionizing the design tools used to build nuclear power plants during the next 10 years. To accomplish this, the DOE has brought together the national laboratories, U.S. universities, and the nuclear energy industry to establish the Nuclear Energy Advanced Modeling and Simulation (NEAMS) Program. The mission of NEAMS is to modernize computer modeling of nuclear energy systems and improve the fidelity and validity of modeling results using contemporary software environments and high-performance computers. NEAMS will create a set of engineering-level codes aimed at designing and analyzing the performance and safety of nuclear power plants and reactor fuels. The truly predictive nature of these codes will be achieved by modeling the governing phenomena at the spatial and temporal scales that dominate the behavior. These codes will be executed within a simulation environment that orchestrates code integration with respect to spatial meshing, computational resources, and execution to give the user a common 'look and feel' for setting up problems and displaying results. NEAMS is building upon a suite of existing simulation tools, including those developed by the federal Scientific Discovery through Advanced Computing and Advanced Simulation and Computing programs. NEAMS also draws upon existing simulation tools for materials and nuclear systems, although many of these are limited in terms of scale, applicability, and portability (their ability to be integrated into contemporary software and hardware architectures). NEAMS investments have directly and indirectly supported additional NE research and development programs, including those devoted to waste repositories, safeguarded separations systems, and long-term storage of used nuclear fuel. NEAMS is organized into two broad efforts, each comprising four elements. The quarterly highlights October-December 2011 are: (1) Version 1.0 of AMP, the fuel assembly performance code, was tested on the JAGUAR supercomputer and released on November 1, 2011, a detailed discussion of this new simulation tool is given; (2) A coolant sub-channel model and a preliminary UO{sub 2} smeared-cracking model were implemented in BISON, the single-pin fuel code, more information on how these models were developed and benchmarked is given; (3) The Object Kinetic Monte Carlo model was implemented to account for nucleation events in meso-scale simulations and a discussion of the significance of this advance is given; (4) The SHARP neutronics module, PROTEUS, was expanded to be applicable to all types of reactors, and a discussion of the importance of PROTEUS is given; (5) A plan has been finalized for integrating the high-fidelity, three-dimensional reactor code SHARP with both the systems-level code RELAP7 and the fuel assembly code AMP. This is a new initiative; (6) Work began to evaluate the applicability of AMP to the problem of dry storage of used fuel and to define a relevant problem to test the applicability; (7) A code to obtain phonon spectra from the force-constant matrix for a crystalline lattice has been completed. This important bridge between subcontinuum and continuum phenomena is discussed; (8) Benchmarking was begun on the meso-scale, finite-element fuels code MARMOT to validate its new variable splitting algorithm; (9) A very computationally demanding simulation of diffusion-driven nucleation of new microstructural features has been completed. An explanation of the difficulty of this simulation is given; (10) Experiments were conducted with deformed steel to validate a crystal plasticity finite-element code for bodycentered cubic iron; (11) The Capability Transfer Roadmap was completed and published as an internal laboratory technical report; (12) The AMP fuel assembly code input generator was integrated into the NEAMS Integrated Computational Environment (NiCE). More details on the planned NEAMS computing environment is given; and (13) The NEAMS program website (neams.energy.gov) is nearly ready to launch.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Next Generation System Analysis Model: Recently Added Features and Future Plans

To better enable informed decision-making regarding the back-end of the nuclear fuel cycle, the Integrated Waste Management System (IWMS) program within the U.S. Department of Energy, Office of Nuclear Energy (DOE-NE) has been sponsoring the development and application of system analysis tools capable of analyzing various system options for the management of spent nuclear fuel (SNF) and high-level radioactive waste (HLW).With these tools, IWMS architecture analyses are being conducted to support the future deployment of a comprehensive nuclear waste management system that considers all major back-end aspects of the nuclear fuel cycle (i.e., transportation, storage, and disposal). The Next Generation System Analysis Model (NGSAM) is an agent-based simulation software tool expressly designed to be capable of modeling features within various IWMS architectures. NGSAM imports data from Oak Ridge National Laboratory (ORNL)’s unified database (e.g., historic assembly information, thermal profiles for assembly heat, and at-reactor dry storage loadings) to ensure that each simulation initializes with a realistic representation of the state of commercial SNF in the U.S. Recent major enhancements implemented into NGSAM in the period since NGSAM was last presented at the WM2019 conference include: • Tracking of railroad escort car acquisition and buffer car acquisition • The addition of heavy haul truck (HHT) and barge routes for some sites, as well as support for user-defined inter-modal routes • Updates to the logic that checks the transportation cask thermal limit maps prior to package transport • An allocation method that predicts when reactor sites would pack assemblies from their spent fuel pools for dry storage, and prioritizes shipments directly from the pools of those reactor sites in the preceding periods (before the predicted loadings to dry storage), thus reducing the number of casks loaded into dry storage at reactor sites • The addition of “reactor site family” operational limits to restrict the number of loads of SNF taken from the pool and from dry storage at a given reactor site each year • Added support for multiple canister loading map options and packages with multiple compatible transportation overpacks • Updates to the handling of non-commercial SNF, including a new database that contains data to support the updates • Updates to allow analysis of hypothetical scenarios which include repackaging at reactor sites, e.g., for possible comparative analysis with other scenarios • Implementation of additional output reports, or modification of existing ones • The ability to generate and implement user edits via the NGSAM website • The ability to model loading SNF from pool storage at an interim storage facility (ISF) into dry storage at the ISF • The ability to model consolidating SNF from different existing storage containers at a DOE site into the same DOE standard canister • The ability to model transferring SNF casks from one transportation mode to another, e.g., from HHT to rail, referred to as transloading. These new features have improved NGSAM capabilities and users’ experience with the model. Preliminary NGSAM requirements for modeling advanced reactor fuels, reprocessing, treatment, and conditioning were considered, and this paper describes them at a high level. Other nuclear fuel cycle system analysis tools developed under sponsorship of DOE-NE, like the VISION code developed at Idaho National Laboratory, might be better suited for initial high-level analysis of those technologies and advanced fuel cycles. As technologies are developed and system concepts evolve, NGSAM could provide value by providing more detailed modeling of transport, storage, and disposal of spent fuel and wastes from advanced reactors and advanced fuel cycles at the fuel element and waste container level.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effects of mesh resolution on large eddy simulation of reacting flows in complex geometry combustors

The power of current parallel computers is becoming sufficient to apply large eddy simulation (LES) tools to reacting flows not only in academic configurations but also in real gas turbine chambers. The most limiting factor in performing LES of real systems is the mesh size, which directly controls the overall cost of the simulation, so that the effects of mesh resolution on LES results become a key issue. In the present work, an unstructured compressible LES solver is used to compute the reacting flow in a domain corresponding to a sector of a realistic helicopter chamber. Three grids ranging from 1.2 to 44 million elements are used for LES and results are compared in terms of mean and fluctuating fields as well as of pressure spectra. Results show that the mean temperature, reaction rate, and velocity fields are almost insensitive to the grid size. The RMS field of the resolved velocity is also reasonably independent of the mesh, while the RMS fields of temperature exhibit more sensitivity to the grid, as expected from the fact that most of the combustion process proceeds at small scales. The acoustic field exhibits a limited sensitivity to the mesh, suggesting that LES is adapted to the computation of combustion instabilities in complex systems. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗