At least 1,585 records · Page 88

A simple and highly efficient protocol for 13 C-labeling of plant cell wall for structural and quantitative analyses via solid-state nuclear magnetic resonance

Plant cell walls are made of a complex network of interacting polymers that play a critical role in plant development and responses to environmental changes. Thus, improving plant biomass and fitness requires the elucidation of the structural organization of plant cell walls in their native environment. The 13 C-based multi-dimensional solid-state nuclear magnetic resonance (ssNMR) has been instrumental in revealing the structural information of plant cell walls through 2D and 3D correlation spectral analyses. However, the requirement of enriching plants with 13 C limits the applicability of this method. To our knowledge, there is only a very limited set of methods currently available that achieve high levels of 13 C-labeling of plant materials using 13 CO 2 , and most of them require large amounts of 13 CO 2 in larger growth chambers. In this study, a simplified protocol for 13C-labeling of plant materials is introduced that allows ca 60% labeling of the cell walls, as quantified by comparison with commercially labeled samples. This level of 13 C-enrichment is sufficient for all conventional 2D and 3D correlation ssNMR experiments for detailed analysis of plant cell wall structure. The protocol is based on a convenient and easy setup to supply both 13 C-labeled glucose and 13 CO 2 using a vacuum-desiccator. The protocol does not require large amounts of 13 CO 2 . This study shows that our 13 C-labeling of plant materials can make the accessibility to ssNMR technique easy and affordable. The derived high-resolution 2D and 3D correlation spectra are used to extract structural information of plant cell walls. This helps to better understand the influence of polysaccharide-polysaccharide interaction on plant performance and allows for a more precise parametrization of plant cell wall models.

09 BIOMASS FUELS↗

Coupling of high-resolution mass spectrometer and photosynthesis system for comprehensive leaf volatile metabolite profiling

Background Leaf-level biogenic volatile organic compounds (BVOCs) emissions represent a major source of organic gases in the atmosphere, influencing both climate and air quality. These emissions are strongly driven by environmental perturbations, which affect individual plant- to ecosystem-level processes. Uncovering all the BVOCs and understanding how their emissions respond to altered environmental conditions provide critical insights into vegetation-driven changes in atmospheric chemistry. We developed a tandem instrumentation setup that integrates a proton transfer reaction time-of-flight mass spectrometer (PTR-ToF-MS) with parts-per-trillion detection limits and a photosynthetic infrared gas exchange system for the untargeted survey of all the BVOCs. This novel system enables simultaneous, real-time monitoring of BVOC emissions and photosynthetic parameters at the leaf level, offering new opportunities to disentangle the physiological and environmental drivers of VOC release. Furthermore, we established the VOC Analysis and Processing Optimization Resource (VAPOR), an open-access software tool designed for rapid data post-processing and the analysis of the variability of hundreds of BVOCs. We assessed the performance of the tandem system under varying background conditions, using standard gas mixtures and a range of environmental factors. Results Blank emissions were substantially lower for major BVOCs (e.g., isoprene) compared to those observed in plant emissions. Despite this, the observation of background-level VOCs highlights the importance of routinely acquiring and accounting for blank measurements in analyses using the coupled instrumentation. Introduction of known VOC concentrations to the system demonstrated a linear response across different compounds with varying molecular compositions, indicating minimal gas loss regardless of chemical moieties within the coupled instrumentation. We applied the optimized system to investigate the physiological mechanisms driving BVOC emissions across different genotypes of poplar and pennycress. The high mass resolution capabilities of the PTR-ToF-MS, coupled with comprehensive VAPOR-driven data analysis, enabled the identification of several important BVOCs, including methanol and methanethiol; these BVOCs displayed substantial variation across pennycress genotypes and showed concentrations ~ 100–350% higher than the blank. Moreover, isoprene emissions varied significantly among poplar genotypes grown in different potting media. Conclusions Tandem instrumentation offers a powerful tool for profiling volatile molecular markers and elucidating their genetic and environmental underpinnings. This approach enhances our ability to predict BVOC emissions in response to genotype by environmental interactions and contributes to a deeper understanding of vegetation responses to environmental changes.

Biogenic volatile organic compounds↗

Utilization of microalgae for agricultural runoff remediation and sustainable biofuel production through an integrated biorefinery approach

Generally wastewater such agricultural runoff is considered a nuisance; however, it could be harnessed as a potential source of nutrients like nitrates and phosphates in integrated biorefinery context. In the current study, microalgae Chlorella sp. S5 was used for bioremediation of agricultural runoff and the leftover algal biomass was used as a potential source for production of biofuels in an integrated biorefinery context. The microalgae Chlorella sp. S5 was cultivated on Blue Green (BG 11) medium and a comprehensive optimization of different parameters including phosphates, nitrates, and pH was carried out to acquire maximum algal biomass enriched with high lipids content. Dry biomass was quantified using the solvent extraction technique, while the identification of nitrates and phosphates in agricultural runoff was carried out using commercial kits. The algal extracted lipids (oils) were employed in enzymatic trans-esterification for biodiesel production using whole-cell biomass of Bacillus subtilis Q4 MZ841642. The resultant fatty acid methyl esters (FAMEs) were analyzed using Fourier transform infrared (FTIR) spectroscopy and gas chromatography coupled with mass spectrometry (GC–MS). Subsequently, both the intact algal biomass and its lipid-depleted algal biomass were used for biogas production within a batch anaerobic digestion setup. Interestingly, Chlorella sp. S5 demonstrated a substantial reduction of 95% in nitrate and 91% in phosphate from agricultural runoff. The biodiesel derived from algal biomass exhibited a noteworthy total FAME content of 98.2%, meeting the quality standards set by American Society for Testing and Materials (ASTM) and European union (EU) standards. Furthermore, the biomethane yields obtained from whole biomass and lipid-depleted biomass were 330.34 NmL/g VS added and 364.34 NmL/g VS added , respectively. In conclusion, the findings underscore the potent utility of Chlorella sp. S5 as a multi-faceted resource, proficiently employed in a sequential cascade for treating agricultural runoff, producing biodiesel, and generating biogas within the integrated biorefinery concept.

09 BIOMASS FUELS↗

Massively parallel and universal approximation of nonlinear functions using diffractive processors

Nonlinear computation is essential for a wide range of information processing tasks, yet implementing nonlinear functions using optical systems remains a challenge due to the weak and power-intensive nature of optical nonlinearities. Overcoming this limitation without relying on nonlinear optical materials could unlock unprecedented opportunities for ultrafast and parallel optical computing systems. Here, we demonstrate that large-scale nonlinear computation can be performed using linear optics through optimized diffractive processors composed of passive phase-only surfaces. In this framework, the input variables of nonlinear functions are encoded into the phase of an optical wavefront—e.g., via a spatial light modulator (SLM)—and transformed by an optimized diffractive structure with spatially varying point-spread functions to yield output intensities that approximate a large set of unique nonlinear functions–all in parallel. We provide proof establishing that this architecture serves as a universal function approximator for an arbitrary set of bandlimited nonlinear functions, also covering wavelength-multiplexed nonlinear functions as well as multi-variate and complex-valued functions that are all-optically cascadable. Our analysis also indicates the successful approximation of typical nonlinear activation functions commonly used in neural networks, including the sigmoid, tanh, ReLU (rectified linear unit), and softplus. We numerically demonstrate the parallel computation of one million distinct nonlinear functions, accurately executed at wavelength-scale spatial density at the output of a diffractive optical processor. Furthermore, we experimentally validated this framework using in situ optical learning and approximated 35 unique nonlinear functions in a single shot using a compact setup consisting of an SLM and an image sensor. These results establish diffractive optical processors as a scalable platform for massively parallel universal nonlinear function approximation, paving the way for new capabilities in analog optical computing based on linear materials.

Rahman, Md Sadman Sakib [University of California,↗

Characterization of an electrically conductive proppant for fracture diagnostics

Fracture diagnosis with electromagnetic (EM) and electrical tools requires proppants with high electrical conductivity and mechanical strength. Lab measurements of the electrical and hydraulic conductivity of proppants are critical for selecting the best candidates. Such measurements greatly benefit simulations, field tests, and the ultimate application of such proppants in the field. To that end, a new lab protocol is developed for measuring the electrical and hydraulic conductivity of proppants. The lab setup, which mainly includes a resistivity core holder and a Hassler sleeve core holder, allows for simulation of realistic pressure and temperature conditions when making measurements. Petroleum coke (PC) is proposed as a candidate proppant because of its widespread availability and low cost. Lab measurements show that the effective electrical conductivity of pure PC in a model fracture is approximately 5000 S/m, under a closure stress greater than [Formula: see text] (4000 psi). When PC is mixed with sand, the effective electrical conductivity of the mixture decreases with an increasing weight percentage of sand. Although sand degrades the contact between PC particles, the electrical conductivity stays reasonably high (approximately 1700 S/m) when 50% sand is added. Hydraulic conductivity measurements show that when a fracture is propped with pure PC, the measured fracture conductivity is greater than [Formula: see text] ([Formula: see text]) (dimensionless fracture conductivity greater than 100 for a shale with [Formula: see text] or 100 nD permeability) under a confining pressure of [Formula: see text] (6000 psi). This means that a fracture propped with PC is infinitely conductive in a typical shale formation. When sand is added, the fracture’s hydraulic conductivity becomes even higher, which clearly shows PC’s ability of sustaining high stresses. The proposed protocol provides a robust and effective method that can be generalized for lab testing for other candidate proppants. The data presented clearly show that PC has the potential for field-scale applications in EM hydraulic fracture diagnostics.

Geochemistry & Geophysics↗

Improving Mathematical Exposition of an Industrial-Scale Linear Program

Industrial-scale models require considerable setup time; hence, once built, they are used in myriad ways to consider closely related cases. In practice, the code for these models frequently evolves without appropriate notational choices, largely as a result of the lengthy development time of, and the number of individuals contributing to, their formulation. This leads to inefficiencies and obfuscates model structures that might be leveraged to expedite solutions. In this paper, we advocate for an emerging literature on model formulation “best practices” and present the reformulation of a widely used industrial-scale linear program. The efficient mathematical expression of this linear program, used to plan capacity expansion in the energy sector, allows for greater transparency of model structures and enhanced ability to identify computational performance improvements, as well as a lucid interpretation of its solutions. This type of formulation is employed in several mathematical programming courses at our university as an example of the advantages of best practices; the model more broadly is used widely to inform policy in the U.S. energy sector.

97 MATHEMATICS AND COMPUTING↗

A Cost-Effective Electro-Hydraulic Actuator Solution with Open Circuit Architecture

With the recent electrification trend in the fluid power area, more research has been incentivized to propose cost-effective and energy-efficient solutions for hydraulic systems. Hence, electro-hydraulic actuator (EHA) architectures receive increasing attention. The paper proposes a novel open-circuit EHA architecture, with the goal to obtain a cost-effective solution for mobile applications while maximizing the overall system efficiency. The proposed EHA is capable of meeting or exceeding traditional off-road machine performance, therefore enabling further electrification of off-road machines. Four-quadrant functionality, covering the full speed range, is achieved by a combination of a variable electro-hydraulic drive and valves with different functions. Focusing on the steady-state performance, the functionality is validated by numerical as well as experimental methods. A simulation model based on the Amesim environment and a dedicated test setup was developed to verify the performance. Furthermore, the good match between simulation and experimental results confirms the potential of the formulation approach of the proposed EHA for applications with different duty cycles and power levels.

4-quadrant functionality↗

Thermal images collected during large-scale 3D printing with Ingersoll MasterPrint

This data set contains images produced to test the performance of anomaly and fault detection methods in the context of additive manufacturing. Two print jobs were executed using the Ingersoll MasterPrint with the Model 30 Strangpresse extruder. The material used was Techmer compounded polylactic acid (PLA) with wood flour as a filler (80/20 PLA/WF by weight). The first print job consists of the 3D printing of a hexagonal cylinder with a two-bead wall. This print was sliced at a gantry velocity of 3000 millimeter per minute, and an extruder screw speed of 68.14 rotations per minute. This are considered the normal operating conditions. A second hexagonal cylinder was printed using a reduced extruder screw speed, 15% lower than under normal operating conditions. The images were collected with a Teledyne FLIR Lepton 3.5 infra-red camera, a small form factor radiometric long-wave infrared camera with a spectral range of 8 µm to 14 µm. Sensor resolution was 160x120 pixels, with a pixel size of 12 µm, a temperature range of -10 - 450°C, and an accuracy of +/- 10°C in its low gain configuration. Images in this data set were collected with cameras oriented at the printer nozzle. The nozzle camera setup consisted of two cameras located 12.5cm from the nozzle center. These were mounted directly to the print head, so that the camera positions relative to the print direction would remain constant as it rotated around its C-axis to follow the print path. One camera was placed ahead of the nozzle to capture the previous layer immediately before being covered by the new layer of material, while the second camera was placed behind the nozzle and captured the freshly extruded bead. Images are collecting during each phase of the print: (a) idle (i.e., no material deposited), (b) extrusion (i.e., to prime the extruder), and (c) printing (deposition of material to manufacture the hexagonal cylinder).

36 MATERIALS SCIENCE↗

Selected 3D Flash-X Checkpoints for the Long-Time Evolution of a 9.6 Solar-Mass Core-Collapse Supernova Model

This dataset contains selected 3D Flash-X checkpoint files from the long-time evolution of a low-energy core-collapse supernova explosion of a 9.6 Msun zero-metallicity, low-mass iron-core progenitor. The checkpoints span the shock-breakout phase through the young-remnant phase, ending at approximately 3 yr after core bounce. The dataset is intended for follow-up analysis and post-processing, especially radiation-transport calculations using the hydrodynamic and compositional structure of the ejecta. For a full description of the numerical setup, physical assumptions, limitations, and interpretation of the simulation, users should refer to the associated paper.

79 ASTRONOMY AND ASTROPHYSICS↗

Preliminary RAM-RODD results for the MUSiC subcritical configurations

The Measurement of Uranium Subcritical and Critical (MUSiC) was performed at the DOE’s National Criticality Experiments Research Center (NCERC) located in the Nevada National Security Site (NNSS). The measurement utilized the Rocky Flats shells to perform benchmark measurements of similar highly enriched uranium (HEU) systems that span a wide range of reactivities. The Rocky Flats (RF) shells are 93.16% U-235 enriched metal hemishells that can be stacked concentrically. Ten configurations were measured with effective multiplication factors spanning between deeply subcritical (~ 0.64) through delayed critical. Details of the measured configurations are listed in Table 1. This unique set of measurements with its large span of reactivies is being used to determine the range over which neutron noise techniques such as Feynman variance-to-mean, Rossi-alpha, and pulsed neutron source techniques can be accurately employed for a bare HEU system. The results of the measurements will be published as a benchmark in The International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The results will support the growing amount of subcritical benchmark data, such as the SCRaP measurements, that is available to the community. The measurements were performed using several different detector systems for the purposes of cross-validation and obtaining detector independent results. Four detector systems were deployed, three by the NCERC team and one from the University of Michigan. The detector systems included a Neutron Multiplicity Array Detector (NoMAD) system (similar to the MC-15), four small volume 0.635 cm (Ø) × 7.59 cm 3 He detectors (ideal for measuring prompt neutron decay constants due to their fast recovery speed), the Rossi Alpha Measurements – Rapid Organic (n, γ) Discrimination Detector (RAM-RODD), and the Organic Scintillator Array (OSCAR). RAM-RODD is an array of eight 5.08 cm (Ø) × 5.08 cm EJ-309 organic scintillator detectors. OSCAR is a University of Michigan system and is an array of twelve 5.08 cm (Ø) × 5.08 cm stilbene detectors. Details of measurements performed with OSCAR will be discussed in a separate talk. The focus of this work is preliminary results obtained by RAM-RODD for the 8 subcritical configurations. Additional details on the measurements and on the setup and deployment of RAM-RODD will be discussed. Preliminary neutron noise analysis results including Rossi-alpha and Feynman-alpha will also be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling In-Reactor Temperature Gradients in Lithium Aluminate Ceramic Pellets

In reactor thermal performance of lithium aluminate ceramic pellets are calculated to determine operating temperatures if internal components shift during irradiation. A 2D conduction model was setup to model this scenario with additional physics, including thermal expansion of components to reactor temperatures, creep down of the cladding due to differential pressure between the inside of the rod and reactor coolant system, and net radiation exchange between components. The non-linear coupling of the governing equations presented convergence challenges due to the very different effects from a small temperature change on the radiation vs radial and circumferential conduction equations. Initial temperature guesses for the multidimensional solution were provided from conservative 1D models simulating bounding scenarios. Convergence was greatly improved by taking small steps towards the root solutions and averaging with initial guesses. The final method robustly converged all 132 points at an axial plane after a few dozen iterations. The temperature results show that the additional physics have a secondary effect as the dominant heat transfer mechanism is radial conduction across the gas gap followed by circumferential conduction around components. Circumferential conduction in the lithium aluminate pellets is enhanced by the relatively high thermal conductivity of this ceramic.

Carstens, Nathan A.↗

Increased phase precision of spatial light modulators using irrational slopes: application to attosecond metrology

The ability of spatial light modulators (SLMs) to modify the amplitude and phase of light has proved them invaluable to the optics and photonics community. In many applications, the bit-depth of SLMs is a major limiting factor dictated by a digital processor. As a result, there is usually a compromise between refresh speed and bit-depth. Here, we present a method to increase the effective bit-depth of SLMs, which utilizes a linear slope, as is commonly applied to deal with the zeroth-order effect. This technique was tested using two interferometric transient absorption spectroscopy setups. Through the high harmonic generation in gases producing a train of attosecond pulses and harmonics from solids in the ultraviolet, two pulses are generated that interfere in the far field providing a measurement of the optical phase. An increase in the precision far beyond the limit dictated by the digital processor in the bit-depth was found.

Harrison, Geoffrey R. (ORCID:0000000152141866)↗

Low-loss adiabatic fiber-optic coupler for cryogenic photonics

Recent developments in quantum light–matter coupled systems and quantum transducers have highlighted the need for cryogenic optical measurements. In this study, we present a packaged fiber-optic coupler with a coupling efficiency of over 50% for telecom wavelength light down to the mK temperature range. Besides the high coupling efficiency, our method enables sensitive photonic device measurements that are immune to mechanical vibrations present in cryogenic setups.

Optics↗

Polarization-entangled source for flex-grid C+L-band quantum networks

We demonstrate an ultrabroadband polarization-entangled source integrating both C- and L-band wavelength-selective switches for spectral routing and allocation in a single fiberized setup, verifying high fidelity through tomography of all 150 pairs of 25 GHz-wide channels.

Alshowkan, Muneer↗

Four-dimensional dynamics of multirotational transition stimulated rotational Raman scattering in air

Stimulated rotational Raman scattering in air is a powerful parasitic process that degrades high intensity laser beams and pulses propagated over significant distances. Conversely, it is used beneficially in the context of Raman lasers. Through this inelastic scattering process, laser photons are converted to higher (anti-Stokes) or lower (Stokes) energies, according to rotational mode transitions in nitrogen and oxygen diatomic molecules. The full wave-mixing problem involves numerous frequencies, and it is consistently assumed that only one rotational mode contributes to the conversion process. We instead present a dynamic 4D multirotational model that is implemented in a parallelized manner within the Virtual Beamline++ optical modeling package allowing high-resolution 4D studies. We highlight the effect that spontaneous emission plays in large and small beam-width setups, even in the highly saturating regime. The weaker transition modes play a large role in the persistent dynamics and can lead to complex spatiotemporal coupling through nonlinear competition of the modes. We highlight how and why these weaker modes persist, how the size and shape of speckle patterns depends highly on the initial beam profile, and how weaker modes can transiently become stronger as a result of such competition.

47 OTHER INSTRUMENTATION↗

High-precision millimeter-wave frequency determination through plasmonic photomixing

We present a technique for high-precision millimeter-wave frequency determination through plasmonic photomixing. Our technique utilizes a plasmonic photomixer pumped by an optical frequency comb with a high-stability millimeter-wave beat frequency. The plasmonic photomixer down-converts the millimeter-wave signal to the radio frequency regime at which high-accuracy frequency counters are available. The precision of this technique is determined by the frequency stability of the optical beat frequency, which can be directly characterized in the presented experimental setup. We demonstrate frequency measurement precision as low as 3.9×10 −10 at 95 GHz through plasmonic photomixing without phase-locking the optical frequency comb.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multiplexing of frequency-modulation spectroscopy by spread-spectrum codes, demonstrated in continuous-wave LIDAR

Frequency-modulation spectroscopy (FMS) is generally suited to code-division multiplexing, and we demonstrate that capacity in a form of continuous-wave LIDAR, utilizing a sharp CO 2 absorption transition at 1.6 µm in simple ranging setups. The approach retains the advantages of FMS, including coherent detection and good rejection of broad absorption backgrounds. Extensions of this multiplexed approach to the continuous, simultaneous detection of several transitions would come by transmitting an encoded combination of frequency-modulated carriers, each tuned to detect a unique absorption transition. Signal analysis at the receiver involves a simple process of de-multiplexing that, in a general application, reveals targets at various distances and the absorption-related FMS signals in between.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

1 GW peak power and 100 J pulsed operation of a diode-pumped Tm:YLF laser

We report on the generation of high energy, high power pulses in a tabletop diode-pumped Tm:YLF-based laser system, which delivers amplified pulse energies up to 108 J, as well as GW peak power performance when seeded with nanosecond duration pulses. Furthermore, the high power and efficiency capabilities of operating Tm:YLF in the multi-pulse extraction (MPE) regime were explored by seeding the experimental setup with a multi-kHz burst of pulses exhibiting a low individual pulse fluence, resulting in a 3.6 kW average power train of multi-joule-level pulses with an optical-to-optical efficiency of 19%.

47 OTHER INSTRUMENTATION↗