Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Building Datasets and Training Methods for ML Based Magnet Quench Detection

Detecting quenches in superconducting (SC) magnets during training is a challenging process that involves capturing physical events that occur at different frequencies and appear as various signal features. These events may be correlated across instrumentation type, thermal cycle, and ramp. These events together build a more complete picture of continuous processes occurring in the magnet, and may allow us to flag potential precursors for quench detection. We present our work on building an automatic machine learning (ML) based quench detection system. We build upon our existing work on unsupervised auto-encoders for acoustic sensors and quench antenna (QA) by first establishing a supervised ML training pipeline. We show the results of an event tagging, analysis, and simulation framework on our QA and acoustic data which are used concurrently to build a training dataset for a supervised implementation. We then show how this supervised training can be used as a prior in a semi-supervised framework and compare this to the unsupervised neural network auto-encoder performance.This allows us to have a more concrete understanding of the performance of our algorithms relative to physical events occurring in the magnet, and also provides a baseline software tool to generically evaluate our quench prediction autoencoders under completely unsupervised, supervised, and semi-supervised training conditions.

Khan, Maira [Fermilab]↗

Sensitivity of ultralight axion dark matter search with optical quantum sensors

An optical quantum sensor (OQS) based on lasers and alkali-metal atoms is a sensitive ambient-temperature magnetometer that can be used in axion dark matter search with an inductor-capacitor (LC) circuit at kHz and MHz frequencies. We have previously investigated the sensitivity of an LC circuit-OQS axion detector to ultralight axion dark matter that could be achieved using a fT-noise OQS constructed in our lab. In this paper, we investigate the sensitivity that could be potentially reached by an OQS performing close to the fundamental quantum noise levels of 10 aT / $\sqrt{Hz}$. To take advantage of the quantum-limited OQS, the LC circuit has to be made of a superconductor and cooled to low temperature of a few K. After considering the intrinsic noise of the advanced axion detector and characterizing possible background noises, we estimate that such an experiment could probe benchmark QCD axion models in an unexplored mass range near 10 neV. Reaching such a high sensitivity is a difficult task, so we have conducted some preliminary experiments with a large-bore magnet and a prototype axion detector consisting of a room-temperature LC circuit and a commercial OQS unit. In conclusion, this paper describes the prototype experiment and its projected sensitivity to axions in detail.

79 ASTRONOMY AND ASTROPHYSICS↗

Continuous Water Quality Sensing for FGD Wastewater

The coal fired plant power industry requires new solutions for on-line monitoring of flue gas desulfurization (FGD) wastewaters for regulated trace metals to reduce recurring operating and off-site laboratory analysis costs and provide a high level of confidence of compliance with state and federal discharge guidelines. The University of Alabama at Birmingham (UAB) developed an integrated water sensor package for continuous water quality monitoring of flue gas desulfurization (FGD) wastewaters for concentration measurements of Selenium (Se). UAB utilized a diverse team of University Professors/Staff Members/Student(s) (Engineering and Innovative Technology Development Group), a University Affiliated Research Institution from the local area (Southern Research), and a cost sharing Industry Partner (Metrohm). The team developed and validated a proprietary wet chemistry batch process for water sample preparation; and implemented this process as a fully automated on-line monitor prototype system. This prototype system’s performance was evaluated in both the laboratory and during in-field deployment to a coal fired power plant. In both environments it was found that the prototype system was unable to recreate the batch process’s success at preparing FGD water samples for total Se measurements with a commercial-off-the-shelf (COTS) cyclic anodic stripping voltammetry (CSV) system. Through this experience, UAB has provided insight into a number of specific areas where improvements can be made with respect to the COTS systems used in this project to yield a more complete and competitive industry solution for on-line monitoring of total Se in industrial wastewater.

01 COAL, LIGNITE, AND PEAT↗

Strain gauge for testing microreactor hexagonal core blocks in the Single Primary Heat Extraction and Removal Emulator

To support the development and deployment of microreactor technologies, experiments that help verify and validate reactor systems and components are performed at non-nuclear test facilities. The Single Primary Heat Extraction Removal Emulator at Idaho National Laboratory is one of these test facilities and was used to monitor a test article that has a prototypic geometry of a heat-pipe cooled microreactor core block. To collect crucial temperature and strain data during testing, temperature and strain sensing fiber optics were embedded to the surface of the test article using an ultrasonic additive manufacturing technique. To support and provide benchmark strain data for the embedded sensors, a commercial resistive strain gauge was attached. This report will discuss the results from the deployment of the commercial strain gauge which includes the setup/attachment strategies, data acquisition, and analysis of the strain data.

36 MATERIALS SCIENCE↗

Quantum Sensing of Insulator‐to‐Metal Transitions in a Mott Insulator

Nitrogen vacancy (NV) centers, optically active atomic defects in diamond, have attracted tremendous interest for quantum sensing, network, and computing applications due to their excellent quantum coherence and remarkable versatility in a real, ambient environment. Taking advantage of these strengths, this paper reports on NV-based local sensing of the electrically driven insulator-to-metal transition (IMT) in a proximal Mott insulator. The resistive switching properties of both pristine and ion-irradiated VO 2 thin film devices are studied by performing optically detected NV electron spin resonance measurements. These measurements probe the local temperature and magnetic field in electrically biased VO 2 devices, which are in agreement with the global transport measurement results. In pristine devices, the electrically driven IMT proceeds through Joule heating up to the transition temperature while in ion-irradiated devices, the transition occurs nonthermally, well below the transition temperature. Here, the results provide direct evidence for nonthermal electrically induced IMT in a Mott insulator, highlighting the significant opportunities offered by NV quantum sensors in exploring nanoscale thermal and electrical behaviors in Mott materials.

McLaughlin, Nathan J.↗

Architecture for Quantum-in-the Loop Real-Time Simulations for Designing Resilient Smart Grids

With the power grid growing more complex every day with the inclusion of new sensors and regulatory approvals that enable end-users and small local developers to participate in the grid, it is becoming challenging for conventional smart grid simulation, emulation, and testing technologies to keep up. In this work, we propose that quantum-encoded real-time simulations can be helpful under the new paradigm and operational circumstances to solve optimization problems for power grids. By leveraging the principles of quantum mechanics, the proposed quantum-in-loop (QIL) framework will enable better and faster optimization solutions based on real-world, real-time data streams, facilitating the real-time planning and operations of electrical grids that rely on millions of distributed sensors and controllers. Furthermore, QIL will allow researchers and engineers to assist utilities in designing, developing, and de-risking algorithms to optimize power grid operation and resilience by considering inputs from millions of grid-connected devices. QIL framework is being developed to have a self-limiting triage mechanism, which will help engineers and practitioners identify fundamental physical limits on quantum processors, revealing what quantum algorithms can and cannot do in utility-specific use cases and must continue to count on classical high-performance computing infrastructure.

digital real-time simulation↗

Transfer learning for probabilistic localization of hidden cracks in concrete structures

Abstract The utility of discriminative supervised learning models built using multiple training-data sources is investigated for hidden crack localization in concrete. Feed-forward neural network (FFNN) is chosen as the model architecture, and transfer learning is used to assimilate the information obtained from different sources (computational physics simulations and laboratory experiments). The labeled training data consists of values of a damage index and the known locations of hidden cracks. The classification models need to learn how the presence of damage (hidden cracks) affects the damage index at different sensors for different test conditions. To this end, diagnostic FFNN models are built by sequentially adding and training new hidden layers to assimilate labeled information from computer models (different model geometries, test conditions, crack lengths, crack locations) and laboratory experiments on a plain cement slab. These transfer learning-based models are then used to localize damage in concrete specimens that reflect real-world conditions (i.e., specimens with steel reinforcement and randomly distributed aggregate). The actual damage state in these specimens is determined by extracting cores and performing petrographic studies on the extracted cores. The damage probability estimated by transfer learning-based models is compared with the petrographic damage rating index (DRI) to identify the most suitable approach to train the diagnostic models. The transfer learning-based diagnostic methodology shows promise and could be used in various structural health monitoring applications, where sufficient labeled data are typically not available from a single data source.

Miele, S.↗

A modular chemigenetic calcium indicator for multiplexed in vivo functional imaging

Abstract Genetically encoded fluorescent calcium indicators allow cellular-resolution recording of physiology. However, bright, genetically targetable indicators that can be multiplexed with existing tools in vivo are needed for simultaneous imaging of multiple signals. Here we describe WHaloCaMP, a modular chemigenetic calcium indicator built from bright dye-ligands and protein sensor domains. Fluorescence change in WHaloCaMP results from reversible quenching of the bound dye via a strategically placed tryptophan. WHaloCaMP is compatible with rhodamine dye-ligands that fluoresce from green to near-infrared, including several that efficiently label the brain in animals. When bound to a near-infrared dye-ligand, WHaloCaMP shows a 7× increase in fluorescence intensity and a 2.1-ns increase in fluorescence lifetime upon calcium binding. We use WHaloCaMP1a to image Ca 2+ responses in vivo in flies and mice, to perform three-color multiplexed functional imaging of hundreds of neurons and astrocytes in zebrafish larvae and to quantify Ca 2+ concentration using fluorescence lifetime imaging microscopy (FLIM).

Biochemistry & Molecular Biology↗

Test beam characterization of sensor prototypes for the CMS Barrel MIP Timing Detector

The MIP Timing Detector will provide additional timing capabilities for detection of minimum ionizing particles (MIPs) at CMS during the High Luminosity LHC era, improving event reconstruction and pileup rejection. The central portion of the detector, the Barrel Timing Layer (BTL), will be instrumented with LYSO:Ce crystals and Silicon Photomultipliers (SiPMs) providing a time resolution of about 30 ps at the beginning of operation, and degrading to 50-60 ps at the end of the detector lifetime as a result of radiation damage. In this work, we present the results obtained using a 120 GeV proton beam at the Fermilab Test Beam Facility to measure the time resolution of unirradiated sensors. A proof-of-concept of the sensor layout proposed for the barrel region of the MTD, consisting of elongated crystal bars with dimensions of about 3×3×57 mm3 and with double-ended SiPM readout, is demonstrated. This design provides a robust time measurement independent of the impact point of the MIP along the crystal bar. We tested LYSO:Ce bars of different thickness (2, 3, 4 mm) with a geometry close to the reference design and coupled to SiPMs manufactured by Hamamatsu and Fondazione Bruno Kessler. The various aspects influencing the timing performance such as the crystal thickness, properties of the SiPMs (e.g. photon detection efficiency), and impact angle of the MIP are studied. A time resolution of about 28 ps is measured for MIPs crossing a 3 mm thick crystal bar, corresponding to a most probable value (MPV) of energy deposition of 2.6 MeV, and of 22 ps for the 4.2 MeV MPV energy deposition expected in the BTL, matching the detector performance target for unirradiated devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multispectral and Thermal Imager Onboard Aerial Platforms Instrument Handbook

The MicaSense Altum imager is an off-the-shelf, synchronized multispectral and thermal camera, combined with a Global Positioning System (GPS) unit and downwelling light sensor (DLS). The Altum takes images of the land surface within its field of view (FOV) across five visible bands and one longwave infrared thermal band. The sensor records the radiance and converts it to digital numbers. Imagery is radiometrically corrected, taking into account the sensor calibration, lens distortions, vignette effects, sun angle, and atmospheric effects (scattering and absorption). The photogrammetry software Agisoft PhotoScan v 1.4 is used to align and stitch the images into a larger composite image using the technique of structure from motion image capture to construct a dense cloud and 3D model of the surface, which is used to produce a digital elevation model of the terrain surveyed and orthomosaic imagery. Land surface leaf area index, albedo, and surface skin temperature are provided for the user. The user can perform raster calculations on the imagery to produce various other vegetative indices, which are used to indicate plant health and land surface characteristics, including Normalized Difference Vegetation Index (NDVI), Green Normalized Difference Vegetation Index (GNDVI), Normalized Difference Water Index (NDWI), surface temperature, and Enhanced_vegetation_index (EVI). This code is provided with the readme file for each data set. The images have a resolution of 20-60 cm/pixel, which are subsampled to 100 cm/pixel.

47 OTHER INSTRUMENTATION↗

Self-powered perovskite photon-counting detectors

Metal-halide perovskites (MHPs) have been successfully exploited for converting photons to charges or vice versa in applications of solar cells, light-emitting diodes and solar fuels for which all these applications involve strong light. Here we show that self-powered polycrystalline perovskite photodetectors can rival the commercial silicon photomultipliers (SiPMs) for photon counting. The photon-counting capability of perovskite photon-counting detectors (PCDs) is mainly determined by shallow traps, despite that deep traps also limit charge-collection efficiency. Two shallow traps with energy depth of 5.8 ± 0.8 millielectronvolts (meV) and 57.2 ± 0.1 meV are identified in polycrystalline methylammonium lead triiodide, which mainly stay at grain boundaries and the surface, respectively. We show that these shallow traps can be reduced by grain-size enhancement and surface passivation using diphenyl sulfide, respectively. It greatly suppresses dark count rate (DCR) from >20,000 counts per second per square millimetre (cps mm –2 ) to 2 cps mm –2 at room temperature, enabling much better response to weak light than SiPMs. The perovskite PCDs can collect γ-ray spectra with better energy resolution than SiPMs and maintain performance at high temperatures up to 85 °C. The zero-bias operation of perovskite detectors enables no drift of noise and detection property. Finally, this study opens a new application of photon counting for perovskites that uses their unique defect properties.

47 OTHER INSTRUMENTATION↗

Spatio-Temporal Anomaly Detection with Graph Networks for Data Quality Monitoring of the Hadron Calorimeter

The Compact Muon Solenoid (CMS) experiment is a general-purpose detector for high-energy collision at the Large Hadron Collider (LHC) at CERN. It employs an online data quality monitoring (DQM) system to promptly spot and diagnose particle data acquisition problems to avoid data quality loss. In this study, we present a semi-supervised spatio-temporal anomaly detection (AD) monitoring system for the physics particle reading channels of the Hadron Calorimeter (HCAL) of the CMS using three-dimensional digi-occupancy map data of the DQM. We propose the GraphSTAD system, which employs convolutional and graph neural networks to learn local spatial characteristics induced by particles traversing the detector and the global behavior owing to shared backend circuit connections and housing boxes of the channels, respectively. Recurrent neural networks capture the temporal evolution of the extracted spatial features. We validate the accuracy of the proposed AD system in capturing diverse channel fault types using the LHC collision data sets. The GraphSTAD system achieves production-level accuracy and is being integrated into the CMS core production system for real-time monitoring of the HCAL. We provide a quantitative performance comparison with alternative benchmark models to demonstrate the promising leverage of the presented system.

43 PARTICLE ACCELERATORS↗

Voltammetry measurements in lithium chloride-lithium oxide (LiCl–Li 2 O) salt: An evaluation of working electrode materials

Instrumentation to provide process monitoring (PM) and safeguards for the oxide reduction (OR) step in the electrochemical processing of used oxide nuclear fuel is necessary to ensure equipment is operated as declared. Cyclic voltammetry (CV) has been proposed for real-time monitoring of the operation of an OR process for safeguards purposes. In this study, different materials including 316 stainless steel (SS), tantalum (Ta), molybdenum (Mo), tungsten (W), platinum (Pt), and iridium (Ir) were evaluated as potential working electrode (WE) materials based on their chemical inertness, corrosion resistance, and sensitivity in detecting Li 2 O and other chloride salts in the OR electrolyte. Of the electrodes evaluated, 316 SS, Ir, and Pt all performed reasonably well in the LiCl-Li 2 O electrolyte. Here, stainless steel was operated in the cathodic potential and had reasonable corrosion resistance and is relatively inexpensive. Iridium could be operated in both the cathodic and anodic potentials and was the most corrosion resistant of those evaluated. Platinum is limited to the anodic potential range, had reasonable corrosion resistance, and was the most sensitive to Li 2 O concentrations in the salt. In the development of a stand-alone safeguards instrumentation, our recommendation is a CV sensor fitted with both Ir and Pt WEs. The results in this study may also be helpful for anode material selection in other electrometallurgy industries, such as molten salt electrolysis.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Comparative Analysis of Rear Irradiance Modeling Methods for Bifacial PV Systems on Single-Axis Trackers Under Varying Albedo Conditions

This study compares three rear-side irradiance modeling methods for bifacial PV systems on single-axis trackers: (i) the 2D View Factor (VF) model in PVsyst(R), (ii) the open-source PVFactors VF model, and (iii) the Ray Tracing (RT) technique using bifacial_radiance. Simulations were benchmarked against field measurements from a pilot PV plant with rear-side sensors at the torque tube height. Results show that all models underestimated the non-uniformity of rear irradiance along the module length and overestimated the total rear irradiance incident on the module. However, since bifacial gain represents only a fraction of the system's total energy, the resulting energy yield differences among methods remained within +- 2 % of measured values, which is typical for such simulations. While the overall energy impact is limited, this study characterizes the specific limitations of each modeling approach, supporting further improvements in bifacial PV performance assessment methods.

14 SOLAR ENERGY↗

Analytical methods for online data quality assessment

This chapter provides a comprehensive overview of the main steps for algorithmic sensor signal quality assessment, which can enhance the decision-making process for water resource recovery facility (WRRF) operation and optimization. It introduces the concept of redundancy as the basis for data quality assessment. It also explains the typical data processing pipeline, which consists of preliminary analysis, data pre-processing, and specific algorithmic approaches. Each of these processes is presented and discussed in three separate sections. Importantly, this chapter introduces the main approaches for data quality assessment, provides guidelines for selecting the most suitable one and the key performance indicators to evaluate them and explains how to collect metadata through such an algorithmic approach.

Aguado, Daniel↗

Model Driven Deception for Defense of Operational Technology Environments

Due to the strong integration of real-world physics, OT deception platforms must operate differently than traditional IT deceptions. For instance, turning off a valve will be detected downstream by other sensors because the flow will reduce and stop. Additionally, controllers and applications leverage data from sensors to send control commands to each other. A believable deception must be integrated with the system to project the effects of events. An attack will likely attempt to control the physical process in a negative manner. To make the attacker believe they are achieving their objective, it must predict the effects of these actions, to a reasonable degree. Our approach to simulating a model to generate realistic decoy behavior is explored including description of two approaches: a physics model-based approach and a data driven approach. The performance of two machine learning techniques are investigated in their ability to learn a good enough model of the physics of the system.

97 MATHEMATICS AND COMPUTING↗

CRCNS21 Computational Models of Multisensory Integration by Upper Limb in Humanoids and Amputees

This international collaborative research project between Johns Hopkins University (JHU) and the Technical University of Munich (TUM) investigated how the human brain processes and integrates multiple types of sensory information, such as touch and force, with the goal of improving prosthetic limbs for amputees and advancing sensory capabilities in humanoid robots. The research advanced our understanding of how the brain responds to sensory feedback in upper-limb amputees. Through experiments in which amputees received electrical stimulation while performing phantom hand movements, we demonstrated that sensory feedback activates the cortical sensorimotor and multisensory regions, and that these regions communicate dynamically during stimulation. Experiments with intact-limb participants explored the integration of visual, haptic, and force feedback, as well as in virtual reality motor training, further showing how the brain processes multimodal sensory information. In addition, this research inspired work on examining the reliability of where amputees perceive sensations over time, which contributed to a successful doctoral fellowship for continued investigation. Our collaborators at TUM improved multimodal sensor technology combining tactile and thermal feedback for humanoid robots, demonstrating the feasibility of integrating multiple sensor types into a unified system for detecting and responding to environmental stimuli. The experimental methods and analysis techniques developed across both teams, including functional network analysis and multimodal sensor integration, provide a foundation for future research in prosthetics and robotics. This research benefits the public by generating knowledge about how amputees process restored sensory information. Advances in humanoid sensing contribute to safer human-robot interaction. The project also fostered international collaboration and cross-disciplinary training: one TUM doctoral student spent a summer at JHU working on multimodal sensor integration, while two JHU students traveled to TUM to host workshops on neuromorphic sensory encoding and sensory integration.

42 ENGINEERING↗