Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “reporting tool”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Identification of and Structural Insights into Hit Compounds Targeting N -Myristoyltransferase for Cryptosporidium Drug Development

Each year, approximately 50,000 children under 5 die as a result of diarrhea caused by Cryptosporidium parvum, a protozoan parasite. There are currently no effective drugs or vaccines available to cure or prevent Cryptosporidium infection, and there are limited tools for identifying and validating targets for drug or vaccine development. We previously reported a high throughput screening (HTS) of a large compound library against Plasmodium N-myristoyltransferase (NMT), a validated drug target in multiple protozoan parasite species. To identify molecules that could be effective against Cryptosporidium, we counter-screened hits from the Plasmodium NMT HTS against Cryptosporidium NMT. We identified two potential hit compounds and validated them against CpNMT to determine if NMT might be an attractive drug target also for Cryptosporidium. We tested the compounds against Cryptosporidium using both cell-based and NMT enzymatic assays. We then determined the crystal structure of CpNMT bound to Myristoyl-Coenzyme A (MyrCoA) and structures of ternary complexes with MyrCoA and the hit compounds to identify the ligand binding modes. The binding site architectures display different conformational states in the presence of the two inhibitors and provide a basis for rational design of selective inhibitors.

60 APPLIED LIFE SCIENCES↗

Small-molecule modulation of β-arrestins

β-Arrestins are multifunctional regulators of G-protein-coupled receptor (GPCR) signalling and orchestrate diverse downstream signalling events and physiological responses across the GPCR superfamily. Although GPCR pharmacology has advanced to target orthosteric and allosteric sites, as well as G proteins and GPCR kinases, direct chemical tools to modulate β-arrestin activities have remained conspicuously absent. Here we report the identification of small-molecule inhibitors that selectively target β-arrestins and delineate their mechanism of action through integrated pharmacological, biochemical, biophysical and structural analyses. These inhibitors disrupt β-arrestin engagement with agonist-activated GPCRs, impairing desensitization, internalization and β-arrestin-dependent physiological functions while sparing G protein–receptor coupling. Cryo-electron microscopy, molecular dynamics simulations and structure-guided mutagenesis reveal that one modulator, Cmpd-5, engages a pocket within the central crest of β-arrestin1 formed by the middle, C and lariat loops, a critical receptor-binding interface, stabilizing a distinct conformation that is incompatible with full β-arrestin–receptor engagement. Together, these findings establish a mechanistic framework for β-arrestin modulation, reveal a novel allosteric site for structure-based drug design, and open new avenues for transducer-targeted, pathway-specific GPCR therapeutic agents.

Kahsai, Alem W. [Duke University, Durham, NC (Unit↗

Unusual flaring activity in the blazar PKS 1424-418 during 2008-2011

Context. Blazars are a subset of active galactic nuclei (AGN) with jets that are oriented along our line of sight. Variability and spectral energy distribution (SED) studies are crucial tools for understanding the physical processes responsible for observed AGN emission. Aims. We report peculiar behaviour in the bright γ-ray blazar PKS 1424-418 and use its strong variability to reveal information about the particle acceleration and interactions in the jet. Methods. Correlation analysis of the extensive optical coverage by the ATOM telescope and nearly continuous γ-ray coverage by the Fermi Large Area Telescope is combined with broadband, time-dependent modeling of the SED incorporating supplemental information from radio and X-ray observations of this blazar. Results. We analyse in detail four bright phases at optical-GeV energies. These flares of PKS 1424-418 show high correlation between these energy ranges, with the exception of one large optical flare that coincides with relatively low γ-ray activity. Although the optical/ γ-ray behaviour of PKS 1424-418 shows variety, the multiwavelength modeling indicates that these differences can largely be explained by changes in the flux and energy spectrum of the electrons in the jet that are radiating. We find that for all flares the SED is adequately represented by a leptonic model that includes inverse Compton emission from external radiation fields with similar parameters. Conclusions. Detailed studies of individual blazars like PKS 1424-418 during periods of enhanced activity in different wavebands are helping us identify underlying patterns in the physical parameters in this class of AGN.

Buson, S.↗

[O iii] λ5007 and X-ray properties of a complete sample of hard X-RAY selected AGNs in the local universe

We study the correlation between the [O iii] λ5007 and X-ray luminosities of local active galactic nuclei (AGNs), using a complete, hard X-ray (>10 keV) selected sample in the Swift/BAT 9-month catalog. From our optical spectroscopic observations at the South African Astronomical Observatory and the literature, a catalog of [O iii] λ5007 line flux for all 103 AGNs at Galactic latitudes of |b|>15{sup ∘} is compiled. Significant correlations with intrinsic X-ray luminosity (L{sub X}) are found for both observed (L{sub [O III] }) and extinction-corrected (L{sub [O III]}{sup cor}) luminosities, separately for X-ray unabsorbed and absorbed AGNs. We obtain the regression form of L{sub [O III] }∝ L{sub 2−10 keV}{sup 1.18±0.07} and L{sub [O III]}{sup cor} ∝ L{sub 2−10 keV}{sup 1.16±0.09} from the whole sample. The absorbed AGNs with low (<0.5%) scattering fractions in soft X-rays show on average smaller L{sub [O III]}/L{sub X} and L{sub [O III]}{sup cor}/L{sub X} ratios than the other absorbed AGNs, while those in edge-on host galaxies do not. These results suggest that a significant fraction of this population is buried in tori with small opening angles. By using these L{sub [O III] }versus L{sub X} correlations, the X-ray luminosity function (LF) of local AGNs (including Compton-thick AGNs) in a standard population synthesis model gives much better agreement with the [O iii] λ5007 LF derived from the Sloan Digital Sky Survey than previously reported. This confirms that hard X-ray observations are a very powerful tool to find AGNs with high completeness.

79 ASTRONOMY AND ASTROPHYSICS↗

Studies on magnetocaloric effect of Tb 2 Ni 0.90 Si 2.94 compound

A comparative study has been carried out on the magnetocaloric properties of as-cast and annealed Tb 2 Ni 0.90 Si 2.94 intermetallic compound. While the as-cast material exhibits ferromagnetic cluster-glass behaviour below 9.9 K coexisting with antiferromagnetic (AFM) interaction, the annealed system shows AFM ordering below 13.5 K and spin freezing occurs below 4 K. The compound exhibits moderate magnetocaloric performance with maximum isothermal entropy changes (–ΔS M ) 8.8 and 10.9 J kg –1 K –1 , relative cooling power (RCP) 306 and 365 J kg –1 , along with adiabatic temperature change (ΔT ad ) 5.5 and 8.15 K for 70 kOe magnetic field change in as-cast and annealed forms, respectively. The estimated magnetic entropy change is found to be larger for annealed sample in comparison to that of as-cast analogue. However, the full width at half maxima (FWHM) of –ΔS M (T) behaviour is larger in as-cast compound due to the presence of inherent structural disorder which reduces with thermal annealing. A positive isothermal entropy change (–ΔS M ) and adiabatic temperature change (ΔT ad ) is observed for the as-cast compound in the measured field and temperature region. In contrast, the annealed system exhibits inverse magnetocaloric effect in the low field and temperature region where AFM interactions dominate. Magnetocaloric effect (MCE) is used as a tool to establish a subtle correlation between the observed magnetocaloric effect and the reported magnetic properties of the system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Demonstration of TNSA proton radiography on the National Ignition Facility Advanced Radiographic Capability (NIF-ARC) Laser

We report that proton radiography using short-pulse laser drivers is an important tool in high-energy density (HED) science for dynamically diagnosing key characteristics in plasma interactions. Here we detail the first demonstration of target-normal sheath acceleration (TNSA)-based proton radiography the NIF-ARC laser system aided by the use of compound parabolic concentrators (CPCs). The multi-kJ energies available at the NIF-ARC laser allows for a high-brightness proton source for radiography and thus enabling a wide range of applications in HED science. In this demonstration, proton radiography of a physics package was performed and this work details the spectral properties of the TNSA proton probe as well as description of the resulting radiography quality.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-C-204-06: Monte Carlo Dose Calculation for Kilovoltage X-Ray-Psoralen Activated Cancer Therapy (X-PACT): Preliminary Results

Purpose: X-PACT is an experimental cancer therapy where kV x-rays are used to photo-activate anti-cancer therapeutics through phosphor intermediaries (phosphors that absorb x-rays and re-radiate as UV light). Clinical trials in pet dogs are currently underway (NC State College of Veterinary Medicine) and an essential component is the ability to model the kV dose in these dogs. Here we report the commissioning and characterization of a Monte Carlo (MC) treatment planning simulation tool to calculate X-PACT radiation doses in canine trials. Methods: FLUKA multi-particle MC simulation package was used to simulate a standard X-PACT radiation treatment beam of 80kVp with the Varian OBI x-ray source geometry. The beam quality was verified by comparing measured and simulated attenuation of the beam by various thicknesses of aluminum (2–4.6 mm) under narrow beam conditions (HVL). The beam parameters at commissioning were then corroborated using MC, characterized and verified with empirically collected commissioning data, including: percent depth dose curves (PDD), back-scatter factors (BSF), collimator scatter factor(s), and heel effect, etc. All simulations were conducted for N=30M histories at M=100 iterations. Results: HVL and PDD simulation data agreed with an average percent error of 2.42%±0.33 and 6.03%±1.58, respectively. The mean square error (MSE) values for HVL and PDD (0.07% and 0.50%) were low, as expected; however, longer simulations are required to validate convergence to the expected values. Qualitatively, pre- and post-filtration source spectra matched well with 80kVp references generated via SPEKTR software. Further validation of commissioning data simulation is underway in preparation for first-time 3D dose calculations with canine CBCT data. Conclusion: We have prepared a Monte Carlo simulation capable of accurate dose calculation for use with ongoing X-PACT canine clinical trials. Preliminary results show good agreement with measured data and hold promise for accurate quantification of dose for this novel psoralen X-ray therapy. Funding Support, Disclosures, & Conflict of Interest: The Monte Carlo simulation work was not funded; Drs. Adamson & Oldham have received funding from Immunolight LLC for X-PACT research.

60 APPLIED LIFE SCIENCES↗

TU-H-CAMPUS-IeP1-02: Validation of a CT Monte Carlo Software

Purpose: To validate the in-house developed CT Monte Carlo calculation tool GMctdospp against reference simulation sets provided by the AAPM in the new report 195. Methods: Deposited energy was calculated in four segments (test 1) and two 10 cm long cylinders (test 2) inside a CTDI phantom (following case #4 of the AAPM report 195). The x-ray point source of a given 120 kVp spectrum was collimated to a fan beam with two thicknesses (10 mm, 80 mm) for a static and a rotational setup. In addition, a given chest geometry was used to calculate deposited energy in several organs for a 0° static and a rotational beam (following case #5 of the AAPM report 195). The results of GMctdospp were compared against the particular mean value of the four quoted Monte Carlo codes (EGSnrc, Geant 4, MCNP and Penelope). Results: Calculated values showed no outliers in any of the cases. Differences between GMctdospp and the particular mean Results: Calculated values showed no outliers in any of the cases. Differences between GMctdospp and the particular mean value were always at similar magnitude compared to the quoted codes. For case #4 (CTDI phantom) the relative differences were within 1.5 %, on average 0.4 % and for case #5 (chest phantom) within 2.5 % and on average 0.85 %. Conclusion: The results confirmed an overall uncertainty of the Monte-Carlo calculation chain in GMctdospp being <2.5 %, for most cases even better. This can be considered small compared to other sources of uncertainties, e.g. virtual source and patient models. The photon transport implemented in GMctdospp inside a voxel-based patient geometry was successfully verified.

60 APPLIED LIFE SCIENCES↗

Radiation-Induced Lens Opacities among Interventional Cardiologists: Retrospective Assessment of Cumulative Eye Lens Doses

This study describes the retrospective lens dose calculation methods developed and applied within the European epidemiological study on radiation-induced lens opacities among interventional cardiologists. While one approach focuses on self-reported data regarding working practice in combination with available procedure-specific eye lens dose values, the second approach focuses on the conversion of the individual whole-body dose to eye lens dose. In contrast with usual dose reconstruction methods within an epidemiological study, a protocol is applied resulting in an individual distribution of possible cumulative lens doses for each recruited cardiologist, rather than a single dose estimate. In this way, the uncertainty in the dose estimate (from measurement uncertainty and variability among cardiologists) is represented for each individual. Eye lens dose and whole-body dose measurements have been performed in clinical practice to validate both methods, and it was concluded that both produce acceptable results in the framework of a dose-risk evaluation study. Optimal results were obtained for the dose to the left eye using procedure-specific lens dose data in combination with information collected on working practice. This method has been applied to 421 interventional cardiologists resulting in a median cumulative eye lens dose of 15.1 cSv for the left eye and 11.4 cSv for the right eye. From the individual cumulative eye lens dose distributions obtained for each cardiologist, maxima up to 9-10 Sv were observed, although with low probability. Since whole-body dose values above the lead apron are available for only a small fraction of the cohort and in many cases not for the entire working career, the second method has only been used to benchmark the results from the first approach. This study succeeded in improving the retrospective calculation of cumulative eye lens doses in the framework of radiation-induced risk assessment of lens opacities, but it remains dependent on self-reported information, which is not always reliable for early years. However, the calculation tools developed can also be used to make an assessment of the eye lens dose in current practice.

61 RADIATION PROTECTION AND DOSIMETRY↗

The NRAP Applications Catalog

The NRAP Applications Catalog represents a living collection of studies in the form of reports and journal publications that demonstrate uses cases for the NRAP suite of tools.

NRAP↗

RokBase - Beta

Web based tool and portal to explore and download data associated with Core Characterization Technical Report Series .

Core Characterization↗

Hydropower Baseline Cost Modeling, Version 2

Recent resource assessments conducted by the United States Department of Energy have identified significant opportunities for expanding hydropower generation through the addition of power to non-powered dams and on undeveloped stream-reaches. Additional interest exists in the powering of existing water resource infrastructure such as conduits and canals, upgrading and expanding existing hydropower facilities, and the construction new pumped storage hydropower. Understanding the potential future role of these hydropower resources in the nation’s energy system requires an assessment of the environmental and techno-economic issues associated with expanding hydropower generation. To facilitate these assessments, this report seeks to fill the current gaps in publically available hydropower cost estimating tools that can support the national-scale evaluation of hydropower resources.

13 HYDRO ENERGY↗

Regulatory Technology Development Plan - Sodium Fast Reactor. Mechanistic Source Term - Trial Calculation. Work Plan

The overall objective of the SFR Regulatory Technology Development Plan (RTDP) effort is to identify and address potential impediments to the SFR regulatory licensing process. In FY14, an analysis by Argonne identified the development of an SFR-specific MST methodology as an existing licensing gap with high regulatory importance and a potentially long lead-time to closure. This work was followed by an initial examination of the current state-of-knowledge regarding SFR source term development (ANLART-3), which reported several potential gaps. Among these were the potential inadequacies of current computational tools to properly model and assess the transport and retention of radionuclides during a metal fuel pool-type SFR core damage incident. The objective of the current work is to determine the adequacy of existing computational tools, and the associated knowledge database, for the calculation of an SFR MST. To accomplish this task, a trial MST calculation will be performed using available computational tools to establish their limitations with regard to relevant radionuclide release/retention/transport phenomena. The application of existing modeling tools will provide a definitive test to assess their suitability for an SFR MST calculation, while also identifying potential gaps in the current knowledge base and providing insight into open issues regarding regulatory criteria/requirements. The findings of this analysis will assist in determining future research and development needs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Improved Sampling Algorithms in the Risk-Informed Safety Margin Characterization Toolkit

The RISMC approach is developing advanced set of methodologies and algorithms in order to perform Probabilistic Risk Analyses (PRAs). In contrast to classical PRA methods, which are based on Event-Tree and Fault-Tree methods, the RISMC approach largely employs system simulator codes applied to stochastic analysis tools. The basic idea is to randomly perturb (by employing sampling algorithms) timing and sequencing of events and internal parameters of the system codes (i.e., uncertain parameters) in order to estimate stochastic parameters such as core damage probability. This approach applied to complex systems such as nuclear power plants requires to perform a series of computationally expensive simulation runs given a large set of uncertain parameters. These types of analysis are affected by two issues. Firstly, the space of the possible solutions (a.k.a., the issue space or the response surface) can be sampled only very sparsely, and this precludes the ability to fully analyze the impact of uncertainties on the system dynamics. Secondly, large amounts of data are generated and tools to generate knowledge from such data sets are not yet available. This report focuses on the first issue and in particular employs novel methods that optimize the information generated by the sampling process by sampling unexplored and risk-significant regions of the issue space: adaptive (smart) sampling algorithms. They infer system response from surrogate models constructed from existing samples and predict the most relevant location of the next sample. It is therefore possible to understand features of the issue space with a small number of carefully selected samples. In this report, we will present how it is possible to perform adaptive sampling using the RISMC toolkit and highlight the advantages compared to more classical sampling approaches such Monte-Carlo. We will employ RAVEN to perform such statistical analyses using both analytical cases but also another RISMC code: RELAP-7.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Global Impact Estimation of ISO 50001 Energy Management System for Industrial and Service Sectors

A methodology has been developed to determine the impacts of ISO 50001 Energy Management System (EnMS) at a region or country level. The impacts of ISO 50001 EnMS include energy, CO2 emissions, and cost savings. This internationally recognized and transparent methodology has been embodied in a user friendly Microsoft Excel® based tool called ISO 50001 Impact Estimator Tool (IET 50001). However, the tool inputs are critical in order to get accurate and defensible results. This report is intended to document the data sources used and assumptions made to calculate the global impact of ISO 50001 EnMS.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Software Infrastructure for V&V

This report provides a milestone with a description outlining a need for standardized, shared tools.

97 MATHEMATICS AND COMPUTING↗

Electromagnetic Prediction and Propagation

An electromagnetic finite volume forward solver is implemented to create a suite of forward models that provide the expected response for an air-filled buried structure constructed of concrete and rebar. Model parameters considered are the conductivities and thicknesses of a two-layer subsurface and the nature of VLF plane wave source. By building this suite of models, the results can be packaged into a data set that is both easily callable and requires minimal storage. More importantly, the user is relieved of the time required to manually execute a large number of models. Instead the results are already provided along with an interpolation tool for immediately data access. This document is written in compliance the LDRD reporting requirements for a close-out report on Project 180848.

42 ENGINEERING↗

Activation Study of Isotopically Enriched Samples During Neutron Time-of-Flight Measurements

Over the course of a time-of-flight neutron cross section measurement, the sample isotope(s) of interest are irradiated by neutrons and photons. Ideally, the enriched sample will not have any additional radioactivity after the measurement as compared to the baseline detectable radioactivity (0.6 Bq/g) established prior to acquisition of the sample. This document presents the process for estimating the activation of a stable enriched isotope exposed to a mixed photon and neutron source using tools from the SCALE code system developed at Oak Ridge National Laboratory. The report also presents the activation analysis for the isotopes of current interest: 90;91;92;94 Zr. This information is provided for two sets of Zr samples: one set of ZrO 2 samples, and one set of metal Zr samples. It was determined that, following measurements at the GELINA linear accelerator facility, all of the enriched Zr samples would contain less than 0.6 Bq/g of radioactivity within 183 days after irradiation.

07 ISOTOPE AND RADIATION SOURCES↗