Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “normalization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

A census of the lung: CellCards from LungMAP

The human lung plays vital roles in respiration, host defense, and basic physiology. Recent technological advancements such as single-cell RNA sequencing and genetic lineage tracing have revealed novel cell types and enriched functional properties of existing cell types in lung. The time has come to take a new census. Initiated by members of the NHLBI-funded LungMAP Consortium and aided by experts in the lung biology community, we synthesized current data into a comprehensive and practical cellular census of the lung. Identities of cell types in the normal lung are captured in individual cell cards with delineation of function, markers, developmental lineages, heterogeneity, regenerative potential, disease links, and key experimental tools. This publication will serve as the starting point of a live, up-to-date guide for lung research at https://www.lungmap.net/cell-cards/. We hope that Lung CellCards will promote the community-wide effort to establish, maintain, and restore respiratory health.

COVID↗

The transformation of diamond to graphite: Experiments reveal the presence of an intermediate linear carbon phase

Natural diamonds that have been partially replaced by graphite have been observed to occur in natural rocks. While the graphite-to-diamond phase transition has been extensively studied the opposite of this (diamond to graphite) remains poorly understood. We performed high-pressure and temperature hydrous and anhydrous experiments up to 1.0 GPa and 1300 °C using Amplex premium virgin synthetic diamonds (20–40 μm size) as the starting material mixed with Mg(OH) 2 as a source of H 2 O for the hydrous experiments. The experiments revealed that the diamond-to-graphite transformation at P = 1.0 GPa and T = 1300 °C was triggered by the presence of H 2 O and was accomplished through a three-stage process. Stage 1: diamond reacts with a supercritical H 2 O producing an intermediate 200–500 nm size “globular carbon” phase. This phase is a linear carbon chain; i.e. a polyyne or carbyne. Stage 2: the linear carbon chains are unstable and highly reactive, and they decompose by zigzagging and cross-linking to form sp 2 -hybridized structures. Stage 3: normal, disordered, and onion-like graphite is produced by the decomposition of the sp-hybridized carbon chains which are re-organized into sp 2 bonds. Our experiments show that there is no direct transformation from sp 3 C-bonds into sp 2 C-bonds. Our hydrous high-pressure and high-temperature experiments show that the diamond-to-graphite transformation requires an intermediate metastable phase of a linear hydrocarbon. This process also provides a simple mechanism for the substitution of other elements into the graphite structure (e.g. H, S, O).

36 MATERIALS SCIENCE↗

Leveraging large language models to address data scarcity in machine learning for graphene synthesis

Machine learning in experimental materials science faces significant challenges due to the scarcity of data, which are costly and time-consuming to generate, particularly when relying on in-house experiments. Literature data mining offers a potential solution but introduces issues like mixed data quality, inconsistent formats, and non-uniform reporting of synthesis parameters, resulting in partially missing and heterogeneous features across the dataset. Here, we propose data imputation and feature engineering methods that employ pre-trained large language models (LLMs) to enhance machine learning performance on scarce, heterogeneous datasets, demonstrated on graphene CVD synthesis data and the ML-HydPARK hydrogen storage dataset. GPT models perform data imputation via tailored prompting and semantic normalization of inconsistently reported features through embeddings, for example, to harmonize the complex nomenclature of CVD substrates. Beyond yielding more diverse and richer feature representations than traditional methods such as K-nearest neighbors (KNN) and Multivariate Imputation by Chained Equations (MICE), LLM-based data imputation is evaluated against dataset characteristics and prompting strategies. We vary the level of autonomy granted to the LLM, from generic prompting that leverages pre-trained knowledge for autonomous data generation to data-informed prompting that constrains outputs using target-specific information, and demonstrate which level of autonomy yields superior imputation performance across datasets and feature types. The proposed data engineering methods markedly improve downstream performance; for example, in graphene layer number classification using a support vector machine (SVM), binary accuracy increases from 39% to 65% and ternary accuracy from 52% to 72%. Fine-tuning experiments on both datasets show that combining our proposed LLM-based data imputation and feature encoding methods with numerical machine learning predictors outperforms standalone fine-tuned LLM predictors in data-scarce settings. The proposed strategies emphasize data enhancement techniques rather than refining learning architectures or regularizing loss functions, offering a broadly applicable framework for improving machine learning performance on scarce, inhomogeneous datasets.

Chemical vapor deposition↗

Impact of soiling on Si and CdTe PV modules: Case study in different Brazil climate zones

Soiling, particulate accumulation on photovoltaic (PV) module surfaces, reduces the available solar resource and the resulting generated device power. This case-study summarizes initial results of 5-year research on the contrasting soiling conditions in the tropical, subtropical, and semi-arid climates in Brazil. A major objective is to present a case study of the effects of soiling on PV module performance in different Brazil climate zones that represent the primary areas for the current and expanding Brazil solar installations. For this, the paper presents methodologies to quantify the soiling ratio (SRatio) and soiling rate (SRate) for two representative commercial technologies, polycrystalline or multicrystalline silicon (mc-Si) and thin-film cadmium telluride (CdTe) modules, through soiling monitoring stations deployed in the selected climate regions. An aim is to add to the growing soiling-research knowledge base through addressing these key factors and their relationships to critical electrical, solar resource, thermal, and local meteorological and environmental parameters. This paper presents, evaluates, and compares soiling rates and losses in Belo Horizonte, Minas Gerais (Equatorial Tropical: 19.92° S, 43.99° W), Porto Alegre, Rio Grande do Sul (Humid-Subtropical: 30.05° S, 51.17° W), and Brotas de Macaúbas, Bahia (Semi-Arid: 12.00° S, 42.63° W). The results show that soiling is moderate in all 3-regions, for example with 0.1%/day < SRate < 0.2%/day for Belo Horizonte. Precipitation dominates the cleaning of the modules in the summertime in this climate zone, while it is the major factor year-round in Rio Grande do Sul. Wind is the major issue mitigating the soiling accumulation for the Bahia installation. The methodology incorporates several key refinements, including the normalization and adjustment for the meteorological parameters (temperature, irradiance, wind, precipitation). The evaluations include the region-specific differing effects of non-uniform soiling, natural cleaning, and ambient temperatures.

14 SOLAR ENERGY↗

A machine learning pipeline for identifying infiltration managed aquifer recharge locations from satellite imagery in the San Joaquin Valley, California

This study focuses on an agricultural region in California’s Central Valley, USA, where Managed Aquifer Recharge (MAR) is widely implemented to mitigate groundwater depletion under increasing water demand and climate variability. A deep learning and machine learning framework was developed to identify infiltration-MAR locations using satellite imagery and environmental data. The framework integrates surface water detection from Sentinel-2 imagery, geospatial delineation of water bodies, spatiotemporal tracking of water body dynamics, and supervised classification using meteorological, environmental, and topographic variables. The framework was applied to a 2379 km² study area southwest of Fresno, where 765 water bodies were detected, including 139 identified MAR sites based on publicly available datasets and expert knowledge. The classification model achieved an accuracy of 0.94 and an F1 score of 0.85. Feature importance analysis indicates that cropland, normalized difference vegetation index (NDVI), and evaporation are among the most influential predictors for infiltration-MAR. Notably, the framework suggests that engineered water management in infiltration-MAR systems can disrupt or even reverse the expected positive correlation between surface water extent and precipitation. These findings provide physically interpretable insights into the characteristics of existing infiltration-MAR facilities and demonstrate the potential of the proposed framework as a reproducible, interpretable, and potentially transferable tool for data-driven infiltration-MAR identification and inventory development under growing climatic and hydrological uncertainty.

Classification↗

The X-ray emission of cerium oxide

Using a combination of spectral simulation with FEFF and experimental data for metallic Ce, it has been possible to extract the Cerium Oxide-only M 4,5 X-ray Emission Spectrum (XES) from an experimental result, which had been produced utilizing a combined CeOxide/Ce sample. In this paper, it is shown that the XES emission for CeOxide-only is significantly different for the M 4 and M 5 edges, with the M 4 XES consistent with normal XES and the M 5 XES exhibiting a continued enhancement associated with a threshold effect, connected to Resonant Inverse Photoelectron Spectroscopy (RIPES).

36 MATERIALS SCIENCE↗

The good, the bad, and the ugly: Data-driven load profile discord identification in a large building portfolio

Reducing the overall energy consumption and associated greenhouse gas emissions in the building sector is essential for meeting our future sustainability goals. Recently, smart energy metering facilities have been deployed to enable monitoring of energy consumption data with hourly or subhourly temporal resolution. This unprecedented data collection has created various opportunities for advanced data analytics involving load profiles (e.g., building energy benchmarking programs, building-to-grid integration, and calibration of urban-scale energy models). These applications often need preprocessing steps to detect daily load profile discords, such as: 1) outliers due to system malfunctions (the bad) and 2) irregular energy consumption patterns, such as those resulting from holidays (the ugly) compared to normal consumption patterns (the good). However, current preprocessing methods predominantly focus on filtering using statistical threshold values, which fail to capture the contextual discords of daily profiles. In addition, discord detection algorithms in building research are often aimed at finding individual building-level discords, which are not suitable at a large scale. Thus, here, we develop a method for automated load profile discord identification (ALDI) in a large portfolio of buildings (more than 100 buildings). Specifically, ALDI 1) uses the matrix profile (MP) method to quantify the similarities of daily subsequences in time series meter data, 2) compares daily MP values with typical-day MP distributions using the Kolmogorov-Smirnov test, and 3) identifies daily load profile discords in a large building portfolio. We evaluate ALDI using the metering data of both an academic campus and a residential neighborhood. Our results demonstrate that ALDI efficiently discovers measurement errors by system malfunctions and low energy consumption days in the academic campus portfolio, and it detects unique load shape patterns likely driven by occupant behavior and extreme weather conditions in the residential neighborhood.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Robustness of energy performance of Zero-Net-Energy (ZNE) homes

Zero-net-energy (ZNE) homes produce an adequate amount of energy on-site to meet their energy demand based on source energy for an entire year. California building energy efficiency standards require new residential buildings started in 2020 to be ZNE. For various reasons, a home designed as ZNE may not achieve ZNE performance in real operation. Here we aimed to quantify the robustness of the energy performance of ZNE homes due to weather variability, climate change, and the uncertainty of occupant behavior. A single-family ZNE house, based on the optimal cost-effective design in three California climate zones, was used to develop the EnergyPlus simulation models. Weather variations were considered from a combination of the historical 30 years’ actual meteorological year (AMY) weather data, typical year weather data in TMY3, and future weather data based on Intergovernmental Panel on Climate Change scenarios. Three scenarios of occupant behavior from the energy perspective were defined to represent the uncertainty about occupants’ activities, comfort requirements, and their adaptive interactions with buildings and systems. In terms of annual source energy, the simulation results of the ZNE homes showed: (1) a decrease of 23–38 percent for occupants with energy austerity behavior and an increase of 120–130 percent for occupants with energy wasteful behavior, compared with the baseline assumption of normal occupants; (2) a variation range of –15 percent to +14 percent for the results using 30-year AMY weather data compared with the baseline results using TMY3 weather data; (3) an increase of 10–13 percent with future weather in Fresno and Riverside and a decrease of 15 percent with San Francisco; and (4) climate change can reduce the gap between the austerity and wasteful consumption. These findings provide insights into how ZNE homes may perform in reality and inform architects, engineers, occupants, and policymakers to pay more attention to occupant behavior on design, operation, and regulations of ZNE homes to ensure energy performance robustness.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Generating realistic building electrical load profiles through the Generative Adversarial Network (GAN)

Building electrical load profiles can improve understanding of building energy efficiency, demand flexibility, and building-grid interactions. Current approaches to generating load profiles are time-consuming and not capable of reflecting the dynamic and stochastic behaviors of real buildings; some approaches also trigger data privacy concerns. In this study, we proposed a novel approach for generating realistic electrical load profiles of buildings through the Generative Adversarial Network (GAN), a machine learning technique that is capable of revealing an unknown probability distribution purely from data. The proposed approach has three main steps: (1) normalizing the daily 24-hour load profiles, (2) clustering the daily load profiles with the k-means algorithm, and (3) using GAN to generate daily load profiles for each cluster. The approach was tested with an open-source database – the Building Data Genome Project. We validated the proposed method by comparing the mean, standard deviation, and distribution of key parameters of the generated load profiles with those of the real ones. The KL divergence of the generated and real load profiles are within 0.3 for majority of parameters and clusters. Additionally, results showed the load profiles generated by GAN can capture not only the general trend but also the random variations of the actual electrical loads in buildings. We report the proposed GAN approach can be used to generate building electrical load profiles, verify other load profile generation models, detect changes to load profiles, and more importantly, anonymize smart meter data for sharing, to support research and applications of grid-interactive efficient buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An improved method for direct incident solar radiation calculation from hourly solar insolation data in building energy simulation

Solar radiation considerably influences the energy consumption of buildings and the power production of building integrated photovoltaic (BIPV) systems. Hourly solar insolation (Wh/m 2 ), represented as the amount of solar irradiance collected on the ground during a 1-h period, is the most common solar radiation data available and widely used in weather files applied in building energy modeling programs (BEMPs). Because the solar beam and position vary over time, the use of hourly insolation data as the input might result in errors in the estimation of the direct incident solar radiation on a particular surface. In this study, methods used in BEMPs for direct incident solar radiation calculations are first analyzed, and an improved method adopting a new algorithm for estimating the solar irradiance is proposed. Furthermore, the algorithm assumes that the solar irradiance changes linearly within a 1-h period and can be estimated based on the solar irradiance at the half clock and slope. The collected direct normal solar irradiance data of 2016 from eight solar radiation stations in China were used to demonstrate the proposed method and evaluate its performance by comparing the results with those from three conventional methods used in BEMPs along with the ground truth measurements. In addition, in this study, factors affecting the accuracy of the calculation results are explored. The results of the estimated direct incident solar radiation show that the proposed method achieves the best accuracy, followed by the methods used in DOE-2, EnergyPlus, and DeST. The proposed method guarantees that the hourly direct solar insolation will remain the same and reflects the variation in the direct solar irradiance across a 1-h time frame. The proposed method can be adopted in BEMPs to improve the accuracy of the solar radiation calculation, thereby improving the accuracy of the simulated building performance and the BIPV production.

14 SOLAR ENERGY↗

What are the Impacts on the HVAC System when it Provides Frequency Regulation? – A Comprehensive Case Study with a Multi-Zone Variable Air Volume (VAV) System

Heating, ventilation, and air-conditioning (HVAC) systems in commercial buildings have proven to be a great asset for providing secondary frequency regulation (FR) service to the power grid. However, how the provision of FR service affects the HVAC system Quality of Service (QOS) is still largely unknown. In particular, there exists a controversy regarding the energy efficiency impact. This paper investigates how a HVAC system performance and its associated controls are impacted during and after the FR service. For the assessment, we developed a dynamic Modelica-based medium office building model as a virtual testbed with the Air Handling Unit (AHU) fans providing the FR service. Different regulation capacities (demand levels) and standard test signals under various load profiles in the U.S. are considered. The results show that FR has little or no impact on the HVAC operation and occupant thermal comfort while the building is providing the service if an appropriate regulation capacity is pre-determined. However, if the regulation capacity is overestimated, the quality of the FR service provided by the HVAC system and the HVAC energy efficiency will be affected due to the equipment operating constraints. In addition, the AHU supply air temperature fluctuates, and the controller cannot maintain the desired setpoint as the FR magnitude is increased. After the FR service time, the system takes a certain period to return to normal operation. The recovery period extends with the increase in the FR magnitude. For this case study, there exists a control conflict between the FR control and the existing HVAC control (from ASHRAE Guideline 36-2018) during high load conditions, causing the fan speed to saturate. The fan power consumption could increase significantly; up to 77% increase compared to the baseline was observed. This case study demonstrates that the HVAC system controls need to be enhanced and adapted to minimize the interaction between the FR controller and the indoor environmental controls in order to preserve the HVAC system QOS while (during and after) providing satisfactory FR service.

Lu, Xing↗

Dilated causal convolutional neural networks for forecasting zone airflow to estimate short-term energy consumption

Here this paper investigates the use of dilated causal convolutional neural networks for fine- grained temporal forecasting of building zone states. Specifically, we build and evaluate models using a small set of exogenous features (e.g., external temperature) to autoregressively predict zone airflow setpoints every minute for a 24-hour prediction window. We carefully explore the trade-off between generality and specificity in these models, training and evaluating them based on zone, zone type, month, season, and combinations thereof. When evaluated for a commercial office building in Eastern Washington with 16 zones served by variable air volume air handling units, we find that the highest performance comes from a zone-specific, season-agnostic approach; with it, we obtain an R 2 of 0.704 (averaged over zones) and an average normalized root mean square error (nRMSE) of 0.111. In contrast, the most general model (trained across all zones and seasons) yields an R 2 of only 0.416 and a nRMSE of 0.168, while a baseline zone-specific reduced order model obtains 0.443 R 2 and 0.159 nRMSE. We also report on factors affecting airflow forecasting performance, on the ability of models trained on a specific zone to generalize to other zones, and on the capability of those models trained on a specific month to generalize to other months.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development, calibration, and validation of a novel gray-box energy model for residential split air conditioners

Energy models for vapor compression refrigeration in residential air conditioners have been developed through white-box, gray-box, and black-box methods in decades. However, existing white-box and gray-box models require complicated equations with detailed geometries while black-box models require substantial experimental data. Further, this paper aims to develop and validate a simple gray-box steady-state energy model without the need for detailed geometries, which can accurately predict the cooling capacity and electrical power input based on outdoor and indoor air conditions, and supply airflow rates. First three state variables, including the evaporation and condensation temperatures, and refrigerant mass flowrate, are applied to develop the energy model and are solved by three physical equations, including the energy conservations at the evaporator and condenser, and the refrigerant volume-mass flow correlation of the compressor. Secondly, seven performance property functions related to three state variables and three physical equations are identified and calibrated by simple temperature and power measurements. Finally, field experiments are conducted on a residential air conditioner to calibrate these performance property functions and validate the developed model. The validated results reveal the model can accurately predict the cooling capacity and electrical power input, with the normalized root mean square errors of 2.3% and 0.87% respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coupling thermal energy storage with a thermally anisotropic building envelope for building demand-side management across various US climate conditions

Here, the thermally anisotropic building envelope (TABE) is a novel active building envelope that enhances energy efficiency and thermal comfort in buildings by transferring heat and cold between building envelopes and hydronic loops. When coupled with thermal energy storage (TES) units, the TABE + TES enables the storage of both heat and cold energy captured by the TABE roof or exterior walls. This stored energy can be later released by the TABE floor for indoor heating and cooling, benefiting both the grid and the end user. This paper evaluates the merits of TABE + TES for building demand-side management across various US climate conditions, focusing on peak load shaving, annual energy savings, and cost savings under time-of-use (TOU) electric rate schedules. Simulations were conducted by integrating time-of-day–informed, rule-based control strategies in MATLAB, TABE components and TES units in COMSOL Multiphysics, and whole-building energy analysis in EnergyPlus. A case study using the US Department of Energy’s prototype single-family detached house model in Birmingham, Alabama; Los Angeles, California; Oak Ridge, Tennessee; and Denver, Colorado, showed that the TABE + TES system achieved (1) 70 % peak load shaving in Los Angeles and Denver and 20 % in Birmingham and Oak Ridge; (2) significant peak electricity savings of 351–497 kWh, reducing peak energy consumption by 38 %–78 %; and (3) annual heating cost savings of 0.79 $\$$/m2–1.17 $\$$/m 2 and cooling cost savings of 0.60 $\$$/m 2 –1.17 $\$$/m 2 using a normal utility rate or low-TOU rate. The benefits of employing the TABE + TES system are even more significant under high TOU rates.

25 ENERGY STORAGE↗

From models to reality: a systematic review on simulated and measured residential heat pump energy savings

High-performance HVAC solutions are central to residential energy management. A substantial share of these are electric, reversible-cycle systems, with heat pumps representing the largest portion of current and near-term adoption. This review synthesizes peer-reviewed and grey literature on residential space heating and cooling heat pumps. The academic literature is dominated by modeling (73.8%), with limited field measurement (13.1%). Grey literature from United States serve as a supplemental resource providing measured savings. Conversions from electric-resistance heating consistently show the largest site energy reductions, while oil/propane baselines yield moderate savings, and gas baseline scenario often deliver small and region-dependent savings. This study cross-checks the grey literature measured data with simulation data filtered from the ResStock dataset. The comparison indicates a discrepancy between simulations and measured data: simulated site EUIs are typically lower than measured EUIs, but percentage energy savings fall in similar ranges, implying simulations capture directional effects while underestimating energy use. Factors associated with variability and model–measurement differences include system characterization and control representation (e.g., backup heat engagement, thermostat/setpoint strategies, commissioning/installation quality), occupant behavior, weather normalization, metering scope, and envelope characterization. This paper also outlines the proposed methodology for comparing simulation and measured data for heat pumps. It emphasizes the metrics used for comparison and units harmonization, building characteristics matching, and compact metadata are needed for simulations to match measured data. The proposed methodology is expected to improve the credibility of simulated savings as measured evidence grows.

Yu, Lili↗

Field testing and validation of a low-cost MPC for demand flexibility for grid-interactive K-12 schools

K-12 school buildings account for the highest energy consumption within the public sector. Implementing advanced HVAC controls in grid-interactive K-12 schools could bring substantial economic advantages and grid flexibility. Our previous study demonstrated that a low-cost model predictive control (MPC) solution, which coordinates multiple packaged units, can enable demand flexibility without major hardware upgrades. However, a significant gap remains between academic pilots and market-ready scalable solutions. This paper extends the previous single-site pilot to a multi-site demonstration involving three school campuses (95 total units) through a commercial technology transfer process. Addressing the challenge of verifying performance with sparse field data, we present a new statistical approach using Bayesian methods to estimate the MPC’s effect on peak demand. Unlike traditional methods, this approach robustly quantifies uncertainty in non-normal, limited datasets. The results confirm the solution’s replicability, achieving a 21.6–38.9% reduction in HVAC peak demand (10.8–22.1% at the site-level) with > 98% probability across diverse locations. Finally, we document critical barriers to scaling software-as-a-service (SaaS) solutions–such as API instability and diverse legacy systems–and offer practical strategies to accelerate the commercial adoption of grid-interactive efficient buildings.

Ham, Sang Woo↗

Advanced defrosting techniques in air source heat pumps: A review of vapor injection, thermal energy storage, and experimental frost accumulation data

Electrification is a critical step for reducing greenhouse gas emissions from heating. Air source heat pumps (ASHPs) are a promising alternative to fossil fuel-based systems due to their high coefficients of performance (COP), dual heating and cooling capability, and lower carbon footprint. However, for ASHPs to achieve widespread adoption, they must operate reliably across all climates, including cold regions. Additionally, defrosting techniques should be energy efficient and minimally disruptive to indoor comfort. Vapor injection (VI) technology can address the high-pressure and high-temperature lift challenges encountered in low ambient conditions. More recently, in addition to enhancing heating performance, VI has also been shown to improve the speed and efficiency of reverse cycle defrosting. Likewise, thermal energy storage (TES) has steadily gained attention for its ability to serve as an auxiliary heat source during both normal operation and defrosting. This review analyzes the benefits and limitations of VI- and TES-assisted defrosting approaches. While both technologies show strong potential individually, no studies to date have explored their combined use in ASHP systems. Additionally, to support continued development of defrosting strategies, both in modeling and experimental work, it is critical to establish frost accumulation data under a range of operating conditions. By compiling the available data from the literature, this paper also highlights the limited availability of such experimental data and the wide variation in frosting and defrosting durations and termination criteria, which are often influenced by system design and test setups.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Identification of engine oil-derived ash nanoparticles and ash formation process for a gasoline direct-injection engine

Engine oil-derived ash particles emitted from internal combustion (IC) engines are unwanted by-products, after oil is involved in in-cylinder combustion process. Since they typically come out together with particulate emissions, no detail has been reported about their early-stage particles other than agglomerated particles loaded on aftertreatment catalysts and filters. To better understand ash formation process during the combustion process, here differently formulated engine oils were dosed into a fuel system of a gasoline direct injection (GDI) engine that produces low soot mass emissions at normal operating conditions to increase the chances to find stand-alone ash particles separated from soot aggregates in the sub-20-nm size range. In addition to them, ash/soot aggregates in the larger size range were examined using scanning transmission electron microscopy (STEM)-X-ray electron dispersive spectroscopy (XEDS) to present elemental information at different sizes of particles from various oil formulations. The STEM-XEDS results showed that regardless of formulated oil type and particle size, Ca, P and C were always contained, while Zn was occasionally found on relatively large particles, suggesting that these elements get together from an early stage of particle formation. The S, Ca and P K-edge X-ray absorption near edge structure (XANES) analyses were performed for bulk soot containing raw ash. The linear combination approach & cross-checking among XANES results proposed that Ca 5 (OH)(PO 4 ) 2 , Ca 3 (PO 4 ) 2 and Zn 3 (PO 4 ) 2 are potentially major chemical compounds in raw ash particles, when combined with the STEM-XEDS results. Despite many reports that CaSO 4 is a major ash chemical when ash found in DPF/GFP systems was examined, it was observed to be rarely present in raw ashes using the S K-edge XANES analysis, suggesting ash transformation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗