Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “multiple sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Data Fusion for a Vision-Radiological System for Source Tracking and Discovery

A multidisciplinary approach to allow the tracking of the movement of radioactive sources by fusing data from multiple radiological and visual sensors is under development. The goal is to improve the ability to detect, locate, track and identify nuclear/radiological threats. The key concept is that such widely available visual and depth sensors can impact radiological detection, since the intensity fall-off in the count rate can be correlated to movement in three dimensions. To enable this, we pose an important question; what is the right combination of sensing modalities and vision algorithms that can best compliment a radiological sensor, for the purpose of detection and tracking of radioactive material? Similarly what is the best radiation detection methods and unfolding algorithms suited for data fusion with tracking data? Data fusion of multi-sensor data for radiation detection have seen some interesting developments lately. Significant examples include intelligent radiation sensor systems (IRSS), which are based on larger numbers of distributed similar or identical radiation sensors coupled with position data for network capable to detect and locate radiation source. Other developments are gamma-ray imaging systems based on Compton scatter in segmented detector arrays. Similar developments using coded apertures or scatter cameras for neutrons have recently occurred. The main limitation of such systems is not so much in their capability but rather in their complexity and cost which is prohibitive for large scale deployment. Presented here is a fusion system based on simple, low-cost computer vision and radiological sensors for tracking of multiple objects and identifying potential radiological materials being transported or shipped. The main focus of this work is the development on two separate calibration algorithms for characterizing the fused sensor system. The deviation from a simple inverse square-root fall-off of radiation intensity is explored and accounted for. In particular, the computer vision system enables a map of distance-dependence of the sources being tracked. Infrared, laser or stereoscopic vision sensors are all options for computer-vision implementation depending on interior vs exterior deployment, resolution desired and other factors. Similarly the radiation sensors will be focused on gamma-ray or neutron detection due to the long travel length and ability to penetrate even moderate shielding. There is a significant difference between the vision sensors and radiation sensors in the way the 'source' or signals are generated. A vision sensor needs an external light-source to illuminate the object and then detects the re-emitted illumination (or lack thereof). However, for a radiation detector, the radioactive material is the source itself. The only exception to this is the field of active interrogations where radiation is beamed into a material to entice new/additional radiation emission beyond what the material would emit spontaneously. The aspect of the nuclear material being the source itself means that all other objects in the environment are 'illuminated' or irradiated by the source. Most radiation will readily penetrate regular material, scatter in new directions or be absorbed. Thus if a radiation source is located near a larger object that object will in turn scatter some radiation that was initially emitted in a direction other than the direction of the radiation detector, this can add to the count rate that is observed. The effect of these scatter is a deviation from the traditional distance dependence of the radiation signal and is a key challenge that needs a combined system calibration solution and algorithms. Thus both an algebraic approach as well as a statistical approach have been developed and independently evaluated to investigate the sensitivity to this deviation from the simplified radiation fall-off as a function of distance. The resulting calibrated system algorithms are used and demonstrated in various laboratory scenarios, and later in realistic tracking scenarios. The selection and testing of radiological and computer-vision sensors for the additional specific scenarios will be the subject of ongoing and future work. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

OpenPATH and Itinerum Integration: A Case Study of Merging Open-Source Projects: Preprint

Throughout the transportation sector, multiple mobility tracking platforms have been developed independently, in parallel, with similar use cases and infrastructure. Maintaining such platforms on an individual level can result in duplicated effort. Innovation within the field could be slowed by the limited resource of people working on extremely similar projects. We provide a case study in how such platforms can be combined with low effort and provide an example in the mobility domain of what the resulting integration points, modules and ownership may look like. OpenPATH (formerly e-mission) and Itinerum are two examples of similar independently developed human mobility tracking platforms that extend beyond standard traffic data collection. Due to the open source nature of the projects, members from both teams decided to merge the functionality, thereby only hosting a single data collection process and limiting maintenance of separate intake platforms. On the front-end, specific questionnaire functionality from Itinerum, mainly the ability to display and return questions and results focused on sociodemographic attributes, was integrated into the OpenPATH user interface. On the back-end, an export pipeline stage was created to transport collected data back to the Itinerum database. Upon completion, the OpenPATH application retained its original functionality while adding the ability to export data for future data sharing and creating an avenue to incorporate Itinerum hosted questions and answers. Itinerum benefits from the rich feature set and infrastructure of OpenPATH without losing needed elements such as the questionnaire component. This case study, within the transportation sector, illustrates the various configurations in which open source software can be developed, maintained and deployed.

ADVANCED PROPULSION SYSTEMS↗

On determining dose rate constants spectroscopically

Purpose: To investigate several aspects of the Chen and Nath spectroscopic method of determining the dose rate constants of {sup 125}I and {sup 103}Pd seeds [Z. Chen and R. Nath, Phys. Med. Biol. 55, 6089-6104 (2010)] including the accuracy of using a line or dual-point source approximation as done in their method, and the accuracy of ignoring the effects of the scattered photons in the spectra. Additionally, the authors investigate the accuracy of the literature's many different spectra for bare, i.e., unencapsulated {sup 125}I and {sup 103}Pd sources. Methods: Spectra generated by 14 {sup 125}I and 6 {sup 103}Pd seeds were calculated in vacuo at 10 cm from the source in a 2.7 Multiplication-Sign 2.7 Multiplication-Sign 0.05 cm{sup 3} voxel using the EGSnrc BrachyDose Monte Carlo code. Calculated spectra used the initial photon spectra recommended by AAPM's TG-43U1 and NCRP (National Council of Radiation Protection and Measurements) Report 58 for the {sup 125}I seeds, or TG-43U1 and NNDC(2000) (National Nuclear Data Center, 2000) for {sup 103}Pd seeds. The emitted spectra were treated as coming from a line or dual-point source in a Monte Carlo simulation to calculate the dose rate constant. The TG-43U1 definition of the dose rate constant was used. These calculations were performed using the full spectrum including scattered photons or using only the main peaks in the spectrum as done experimentally. Statistical uncertainties on the air kerma/history and the dose rate/history were Less-Than-Or-Slanted-Equal-To 0.2%. The dose rate constants were also calculated using Monte Carlo simulations of the full seed model. Results: The ratio of the intensity of the 31 keV line relative to that of the main peak in {sup 125}I spectra is, on average, 6.8% higher when calculated with the NCRP Report 58 initial spectrum vs that calculated with TG-43U1 initial spectrum. The {sup 103}Pd spectra exhibit an average 6.2% decrease in the 22.9 keV line relative to the main peak when calculated with the TG-43U1 rather than the NNDC(2000) initial spectrum. The measured values from three different investigations are in much better agreement with the calculations using the NCRP Report 58 and NNDC(2000) initial spectra with average discrepancies of 0.9% and 1.7% for the {sup 125}I and {sup 103}Pd seeds, respectively. However, there are no differences in the calculated TG-43U1 brachytherapy parameters using either initial spectrum in both cases. Similarly, there were no differences outside the statistical uncertainties of 0.1% or 0.2%, in the average energy, air kerma/history, dose rate/history, and dose rate constant when calculated using either the full photon spectrum or the main-peaks-only spectrum. Conclusions: Our calculated dose rate constants based on using the calculated on-axis spectrum and a line or dual-point source model are in excellent agreement (0.5% on average) with the values of Chen and Nath, verifying the accuracy of their more approximate method of going from the spectrum to the dose rate constant. However, the dose rate constants based on full seed models differ by between +4.6% and -1.5% from those based on the line or dual-point source approximations. These results suggest that the main value of spectroscopic measurements is to verify full Monte Carlo models of the seeds by comparison to the calculated spectra.

60 APPLIED LIFE SCIENCES↗

Calibration of a DSSSD detector with radioactive sources

The energy calibration of a DSSSD is carried out with the spectra produced by a {sup 207}Bi conversion electron source, a {sup 137}Cs gamma source and a {sup 239}Pu/{sup 241}Am/{sup 244}Cm triple alpha source, as well as employing a precision pulse generator in the whole dynamic range. Multiplicity and coincidence of signals in different strips for the same event are also studied.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synergistic learning with multi-task DeepONet for efficient PDE problem solving

Multi-task learning (MTL) is an inductive transfer mechanism designed to leverage useful information from multiple tasks to improve generalization performance compared to single-task learning. It has been extensively explored in traditional machine learning to address issues such as data sparsity and overfitting in neural networks. In this work, we apply MTL to problems in science and engineering governed by partial differential equations (PDEs). However, implementing MTL in this context is complex, as it requires task-specific modifications to accommodate various scenarios representing different physical processes. To this end, we present a multi-task deep operator network (MT-DeepONet) to learn solutions across various functional forms of source terms in a PDE and multiple geometries in a single concurrent training session. We introduce modifications in the branch network of the vanilla DeepONet to account for various functional forms of a parameterized coefficient in a PDE. Additionally, we handle parameterized geometries by introducing a binary mask in the branch network and incorporating it into the loss term to improve convergence and generalization to new geometry tasks. Our approach is demonstrated on three benchmark problems: (1) learning different functional forms of the source term in the Fisher equation; (2) learning multiple geometries in a 2D Darcy Flow problem and showcasing better transfer learning capabilities to new geometries; and (3) learning 3D parameterized geometries for a heat transfer problem and demonstrate the ability to predict on new but similar geometries. Finally, our MT-DeepONet framework offers a novel approach to solving PDE problems in engineering and science under a unified umbrella based on synergistic learning that reduces the overall training cost for neural operators.

42 ENGINEERING↗

A multi-phase level set framework for source reconstruction in bioluminescence tomography

We propose a novel multi-phase level set algorithm for solving the inverse problem of bioluminescence tomography. The distribution of unknown interior source is considered as piecewise constant and represented by using multiple level set functions. The localization of interior bioluminescence source is implemented by tracing the evolution of level set function. An alternate search scheme is incorporated to ensure the global optimal of reconstruction. Both numerical and physical experiments are performed to evaluate the developed level set reconstruction method. Reconstruction results show that the proposed method can stably resolve the interior source of bioluminescence tomography.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Control Algorithms Charge Batteries Faster

On March 29, 2011, NASA s Mercury Surface, Space Environment, Geochemistry and Ranging (MESSENGER) spacecraft beamed a milestone image to Earth: the first photo of Mercury taken from orbit around the solar system s innermost planet. (MESSENGER is also the first spacecraft to orbit Mercury.) Like most of NASA s deep space probes, MESSENGER is enabled by a complex power system that allows its science instruments and communications to function continuously as it travels millions of miles from Earth. "Typically, there isn't one particular power source that can support the entire mission," says Linda Taylor, electrical engineer in Glenn Research Center s Power Systems Analysis Branch. "If you have solar arrays and you are in orbit, at some point you re going to be in eclipse." Because of this, Taylor explains, spacecraft like MESSENGER feature hybrid power systems. MESSENGER is powered by a two-panel solar array coupled with a nickel hydrogen battery. The solar arrays provide energy to the probe and charge the battery; when the spacecraft s orbit carries it behind Mercury and out of the Sun s light, the spacecraft switches to battery power to continue operations. Typically, hybrid systems with multiple power inputs and a battery acting alternately as storage and a power source require multiple converters to handle the power flow between the devices, Taylor says. (Power converters change the qualities of electrical energy, such as from alternating current to direct current, or between different levels of voltage or frequency.) This contributes to a pair of major concerns for spacecraft design. "Weight and size are big drivers for any space application," Taylor says, noting that every pound added to a space vehicle incurs significant costs. For an innovative solution to managing power flows in a lightweight, cost-effective manner, NASA turned to a private industry partner.

Source record↗

BrachyView, a novel in-body imaging system for HDR prostate brachytherapy: Experimental evaluation

Purpose: This paper presents initial experimental results from a prototype of high dose rate (HDR) BrachyView, a novel in-body source tracking system for HDR brachytherapy based on a multipinhole tungsten collimator and a high resolution pixellated silicon detector array. The probe and its associated position estimation algorithms are validated and a comprehensive evaluation of the accuracy of its position estimation capabilities is presented. Methods: The HDR brachytherapy source is moved through a sequence of positions in a prostate phantom, for various displacements in x, y, and z. For each position, multiple image acquisitions are performed, and source positions are reconstructed. Error estimates in each dimension are calculated at each source position and combined to calculate overall positioning errors. Gafchromic film is used to validate the accuracy of source placement within the phantom. Results: More than 90% of evaluated source positions were estimated with an error of less than one millimeter, with the worst-case error being 1.3 mm. Experimental results were in close agreement with previously published Monte Carlo simulation results. Conclusions: The prototype of HDR BrachyView demonstrates a satisfactory level of accuracy in its source position estimation, and additional improvements are achievable with further refinement of HDR BrachyView’s image processing algorithms.

60 APPLIED LIFE SCIENCES↗

IER-407 CED-3b Rev-1: Experiment Execution Report for the Inherently Safe Subcritical Assembly (ISSA) Subcritical Measurements

This set of benchmark subcritical multiplicity experiments was conducted at the ISSA experiment center of Lawrence Livermore National Laboratory. The purpose of these subcritical experiments, as described in the ISSA final design report, was to measure fission neutrons by collecting time-tagged data corresponding to a maximum multiplication of approximately 20. The fission source for this experiment was Materials Test Reactor (MTR)-type highly enriched uranium fuel assembly, which is composed of nineteen fuel plates. One, two, four, six and nine ISSA fuel assemblies were closely packed and loaded inside a support fixture assembly and immersed in water. Four 3 He proportional counters were placed around the fuel assemblies, and list-mode experimental data was taken. Additionally, efficiency calibration measurements with calibrated neutron sources were conducted. The LLNL developed codes BIGFIT and OSANTI RESTART will be used to evaluate the measured data and calculate the experimental multiplication.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Isovector charges of the nucleon from 2+1-flavor QCD with clover fermions

Here, we present high-statistics estimates of the isovector charges of the nucleon from four 2 + 1-flavor ensembles generated using Wilson-clover fermions with stout smearing and tree-level tadpole improved Symanzik gauge action at lattice spacings 𝑎 ≈ 0.127 and 0.09 fm and with 𝑀 𝜋 ≈ 280 and 170 MeV. The truncated solver method with bias correction and the coherent source sequential propagator construction are used to cost-effectively achieve 𝑂⁡(1⁢0 5 ) measurements on each ensemble. Using these data, the analysis of two-point correlation functions is extended to include four states in the fits, and of three-point functions to three states. Control over excited-state contamination in the calculation of the nucleon mass, the mass gaps between excited states, and in the matrix elements is demonstrated by the consistency of estimates using this multistate analysis of the spectral decomposition of the correlation functions and from simulations of the three-point functions at multiple values of the source-sink separation. The results for all three charges, 𝑔 𝐴 , 𝑔 𝑆 , and 𝑔 𝑇 , are in good agreement with calculations done using the clover-on-HISQ lattice formulation with similar values of the lattice parameters.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A 5 x 40 cm rectangular-beam multipole ion source

A rectangular ion source particularly suited for the continuous sputter processing of materials over a wide area is discussed. A multipole magnetic field configuration was used to design an ion source with a 5 x 40 cm beam area, while a three-grid ion optics system was used to maximize ion current density at the design ion energy of 500 eV. An average extracted current density of about 4 mA/sq cm could be obtained from 500 eV Ar ions. The difference between the experimental performance and the design value of 6 mA/sq cm is attributed to grid misalignment due to thermal expansion. The discharge losses at typical operating conditions ranged from about 600 to 1000 eV/ion, in reasonable agreement with the design value of 800 eV/ion. The use of multiple rectangular-beam ion sources to process wider areas than would be possible with a single source was also studied, and the most uniform coverage was found to be obtainable with a 0 to 2 cm overlap.

Robinson, R. S.↗

Experimental Determination of the Multiplicity Deadtime Parameter

Definition, extraction, and application of dead-time parameters, in correlated neutron counting, are long standing, thorny issues. Traditionally, dead-time corrections have been estimated on the assumption of a simple paralyzing model, arising from the action of the discriminator in the charged amplifiers connected to the {sup 3}He proportional counters, using a fixed dead-time. Various schemes exist to apply the paralysable model to the multiplicity shift register histogram data. In principle, several methods could be used to estimate the dead-time parameter. The approach which is most widely applied involves measuring a series of Cf-252 sources spanning a wide dynamic range of counting rates. Ratios between the Singles, Doubles and Triples rates which ought to be independent of fissile mass are extracted. The dead-time is chosen so as to achieve the best independence in the ratios, characteristic of the fissioning system, over the counting range. These measurements can be quite laborious to conduct; require a set of Cf-252 sources matched in construction and isotopic composition; require long counts to achieve the requisite precision and involve a good deal of numerical analysis to interpret. In this work we present a simpler scheme which produces comparable values in a way that is easier to implement. In essence we place a near random neutron source, such as may be realized using Am/Li {alpha}-n sources, in the cavity and record the multiplicity histograms as one would for an assay. The variance to mean-squared is narrower than for a random counting experiment, however, as a result of the dead-time losses. A simple formula exists allowing the deadtime to be extracted from this measurement. In this paper, we present results for the traditional approach, the proposed approach and also a variation based on adjusting the total event rate by adding Am/Li sources to a single Cf-252 source fixed in position for the case of a pair of Passive Scrap Multiplicity Counters (PSMC's). Excellent agreement is obtained. Because the variance to mean squared approach gives high precision in a single, short, measurement it lends itself to studying dead-time behaviors systematically as a function of shift register settings, operating voltage and preamplifier trim. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PARALLAX AND ORBITAL EFFECTS IN ASTROMETRIC MICROLENSING WITH BINARY SOURCES

In gravitational microlensing, binary systems may act as lenses or sources. Identifying lens binarity is generally easy, in particular in events characterized by caustic crossing since the resulting light curve exhibits strong deviations from a smooth single-lensing light curve. In contrast, light curves with minor deviations from a Paczyński behavior do not allow one to identify the source binarity. A consequence of gravitational microlensing is the shift of the position of the multiple image centroid with respect to the source star location — the so-called astrometric microlensing signal. When the astrometric signal is considered, the presence of a binary source manifests with a path that largely differs from that expected for single source events. Here, we investigate the astrometric signatures of binary sources taking into account their orbital motion and the parallax effect due to the Earth’s motion, which turn out not to be negligible in most cases. We also show that considering the above-mentioned effects is important in the analysis of astrometric data in order to correctly estimate the lens-event parameters.

79 ASTRONOMY AND ASTROPHYSICS↗

The metagenomics RAST server - a public resource for the automatic phylogenetic and functional analysis of metagenomes.

Random community genomes (metagenomes) are now commonly used to study microbes in different environments. Over the past few years, the major challenge associated with metagenomics shifted from generating to analyzing sequences. High-throughput, low-cost next-generation sequencing has provided access to metagenomics to a wide range of researchers. A high-throughput pipeline has been constructed to provide high-performance computing to all researchers interested in using metagenomics. The pipeline produces automated functional assignments of sequences in the metagenome by comparing both protein and nucleotide databases. phylogenetic and functional summaries of the metagenomes are generated, and tools for comparative metagenomics are incorporated into the standard views. user access is controlled to ensure data privacy, but the collaborative environment underpinning the service provides a framework for sharing databasets between multiple users. In the metagenomics RAST, all users retain full control of their data, and everything is available for download in a variety of formats. The open-source metagenomics RAST service provides a new paradigm for the annotation and analysis of metagenomes. With built-in support for multiple data sources and a back end that houses abstract data types, the metagenomics RAST is stable, extensible, and freely available to all researchers. This service has removed one of the primary bottlenecks in metagenome sequence analysis--the available of high-performance computing for annotating the data.

59 BASIC BIOLOGICAL SCIENCES↗

Investigation of surface termination by directional elastic peak electron spectroscopy: Experiment and theory

Experimental and theoretical details concerning the directional elastic peak electron spectroscopy are presented. The application of this experimental method to the identification of a crystalline structure of surface layers is shown for Cu(111) and Ru(0001), which enables the analysis of different surface terminations associated with different sequences of atoms along the surface normal. Theoretical data are obtained by applying the multiple scattering theory and different sources of phase shifts. The quantitative analysis performed by an R-factor reveals almost the same populations of A and B terminated (0001) terraces and proves explicitly the presence of steps of atomic height on the clean Ru(0001) surface. This is not the case for the Cu(111) surface, where the terrace termination does not affect the distribution of atomic directions within the first few atomic layers. The averaging of theoretical data versus scattering volume defined by the sphere radius R{sub max} around the emitter site is discussed in view of the computation time optimization. - Highlights: • We examined the structure and surface termination of fcc and hcp monocrystals. • Crystalline structure within the first few atomic layers was determined by DEPES. • Multiple scattering formalism was used to obtain theoretical results. • Populations of terraces with different terminations were determined. • Scattering parameters are discussed in the context of computation time optimization.

36 MATERIALS SCIENCE↗

HYDRAFloods Near Real-Time Mapping of Flood Events Using Multiple Satellite Sensors

Information about inundated areas is critical for distributing aid and resources in flood emergency response operations. Conventional methods of monitoring floods, like gauge based observations and reports from local authorities, provide very detailed and accurate information about flood depth and location. However, the geographic coverage of these point-based observations is limited and delays are common. Satellite-based images can help address these challenges, providing near real-time flood extent information over large areas of coverage. The Hydrological Remote Sensing Analysis of Floods (HYDRAFloods) tool, currently being developed by SERVIR-Mekong in collaboration with the Myanmar Department of Disaster Management, is one such example. Generating flood maps, even from satellite imagery, is challenging, given the many disparate sources of information. HYDRAFloods leverages the most recently available remotely sensed data acquired by multiple satellite platforms to automate the creation of daily flood maps. Through combining multiple satellite sources, including optical, microwave, and synthetic aperture radar datasets, near real-time flood maps with reduced cloud impact and increased satellite observations can be generated for use by disaster managers.

Nauman, Claire↗