Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “modulation.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

A Computational Model of Cellular Response to Modulated Radiation Fields

Purpose: To develop a model to describe the response of cell populations to spatially modulated radiation exposures of relevance to advanced radiotherapies. Materials and Methods: A Monte Carlo model of cellular radiation response was developed. This model incorporated damage from both direct radiation and intercellular communication including bystander signaling. The predictions of this model were compared to previously measured survival curves for a normal human fibroblast line (AGO1522) and prostate tumor cells (DU145) exposed to spatially modulated fields. Results: The model was found to be able to accurately reproduce cell survival both in populations which were directly exposed to radiation and those which were outside the primary treatment field. The model predicts that the bystander effect makes a significant contribution to cell killing even in uniformly irradiated cells. The bystander effect contribution varies strongly with dose, falling from a high of 80% at low doses to 25% and 50% at 4 Gy for AGO1522 and DU145 cells, respectively. This was verified using the inducible nitric oxide synthase inhibitor aminoguanidine to inhibit the bystander effect in cells exposed to different doses, which showed significantly larger reductions in cell killing at lower doses. Conclusions: The model presented in this work accurately reproduces cell survival following modulated radiation exposures, both in and out of the primary treatment field, by incorporating a bystander component. In addition, the model suggests that the bystander effect is responsible for a significant portion of cell killing in uniformly irradiated cells, 50% and 70% at doses of 2 Gy in AGO1522 and DU145 cells, respectively. This description is a significant departure from accepted radiobiological models and may have a significant impact on optimization of treatment planning approaches if proven to be applicable in vivo.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intensity Modulated Proton and Photon Therapy for Early Prostate Cancer With or Without Transperineal Injection of a Polyethylen Glycol Spacer: A Treatment Planning Comparison Study

Purpose: Rectal toxicity is a serious adverse effect in early-stage prostate cancer patients treated with curative radiation therapy (RT). Injecting a spacer between Denonvilliers' fascia increases the distance between the prostate and the anterior rectal wall and may thus decrease the rectal radiation-induced toxicity. We assessed the dosimetric impact of this spacer with advanced delivery RT techniques, including intensity modulated RT (IMRT), volumetric modulated arc therapy (VMAT), and intensity modulated proton beam RT (IMPT). Methods and Materials: Eight prostate cancer patients were simulated for RT with or without spacer. Plans were computed for IMRT, VMAT, and IMPT using the Eclipse treatment planning system using both computed tomography spacer+ and spacer- data sets. Prostate {+-} seminal vesicle planning target volume [PTV] and organs at risk (OARs) dose-volume histograms were calculated. The results were analyzed using dose and volume metrics for comparative planning. Results: Regardless of the radiation technique, spacer injection decreased significantly the rectal dose in the 60- to 70-Gy range. Mean V{sub 70Gy} and V{sub 60Gy} with IMRT, VMAT, and IMPT planning were 5.3 {+-} 3.3%/13.9 {+-} 10.0%, 3.9 {+-} 3.2%/9.7 {+-} 5.7%, and 5.0 {+-} 3.5%/9.5 {+-} 4.7% after spacer injection. Before spacer administration, the corresponding values were 9.8 {+-} 5.4% (P=.012)/24.8 {+-} 7.8% (P=.012), 10.1 {+-} 3.0% (P=.002)/17.9 {+-} 3.9% (P=.003), and 9.7 {+-} 2.6% (P=.003)/14.7% {+-} 2.7% (P=.003). Importantly, spacer injection usually improved the PTV coverage for IMRT. With this technique, mean V{sub 70.2Gy} (P=.07) and V{sub 74.1Gy} (P=0.03) were 100 {+-} 0% to 99.8 {+-} 0.2% and 99.1 {+-} 1.2% to 95.8 {+-} 4.6% with and without Spacer, respectively. As a result of spacer injection, bladder doses were usually higher but not significantly so. Only IMPT managed to decrease the rectal dose after spacer injection for all dose levels, generally with no observed increase to the bladder dose. Conclusions: Regardless of the radiation technique, a substantial decrease of rectal dose was observed after spacer injection for curative RT to the prostate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Linear Energy Transfer-Guided Optimization in Intensity Modulated Proton Therapy: Feasibility Study and Clinical Potential

Purpose: To investigate the feasibility and potential clinical benefit of linear energy transfer (LET) guided plan optimization in intensity modulated proton therapy (IMPT). Methods and Materials: A multicriteria optimization (MCO) module was used to generate a series of Pareto-optimal IMPT base plans (BPs), corresponding to defined objectives, for 5 patients with head-and-neck cancer and 2 with pancreatic cancer. A Monte Carlo platform was used to calculate dose and LET distributions for each BP. A custom-designed MCO navigation module allowed the user to interpolate between BPs to produce deliverable Pareto-optimal solutions. Differences among the BPs were evaluated for each patient, based on dose–volume and LET–volume histograms and 3-dimensional distributions. An LET-based relative biological effectiveness (RBE) model was used to evaluate the potential clinical benefit when navigating the space of Pareto-optimal BPs. Results: The mean LET values for the target varied up to 30% among the BPs for the head-and-neck patients and up to 14% for the pancreatic cancer patients. Variations were more prominent in organs at risk (OARs), where mean LET values differed by a factor of up to 2 among the BPs for the same patient. An inverse relation between dose and LET distributions for the OARs was typically observed. Accounting for LET-dependent variable RBE values, a potential improvement on RBE-weighted dose of up to 40%, averaged over several structures under study, was noticed during MCO navigation. Conclusions: We present a novel strategy for optimizing proton therapy to maximize dose-averaged LET in tumor targets while simultaneously minimizing dose-averaged LET in normal tissue structures. MCO BPs show substantial LET variations, leading to potentially significant differences in RBE-weighted doses. Pareto-surface navigation, using both dose and LET distributions for guidance, provides the means for evaluating a large variety of deliverable plans and aids in identifying the clinically optimal solution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dynamic Collimator Angle Adjustments During Volumetric Modulated Arc Therapy to Account for Prostate Rotations

Purpose: Rotations of the prostate gland induce considerable geometric uncertainties in prostate cancer radiation therapy. Collimator and gantry angle adjustments can correct these rotations in intensity modulated radiation therapy. Modern volumetric modulated arc therapy (VMAT) treatments, however, include a wide range of beam orientations that differ in modulation, and corrections require dynamic collimator rotations. The aim of this study was to implement a rotation correction strategy for VMAT dose delivery and validate it for left-right prostate rotations. Methods and Materials: Clinical VMAT treatment plans of 5 prostate cancer patients were used. Simulated left-right prostate rotations between +15° and −15° were corrected by collimator rotations. We compared corrected and uncorrected plans by dose volume histograms, minimum dose (D{sub min}) to the prostate, bladder surface receiving ≥78 Gy (S78) and rectum equivalent uniform dose (EUD; n=0.13). Each corrected plan was delivered to a phantom, and its deliverability was evaluated by γ-evaluation between planned and delivered dose, which was reconstructed from portal images acquired during delivery. Results: On average, clinical target volume minimum dose (D{sub min}) decreased up to 10% without corrections. Negative left-right rotations were corrected almost perfectly, whereas D{sub min} remained within 4% for positive rotations. Bladder S78 and rectum EUD of the corrected plans matched those of the original plans. The average pass rate for the corrected plans delivered to the phantom was 98.9% at 3% per 3 mm gamma criteria. The measured dose in the planning target volume approximated the original dose, rotated around the simulated left-right angle, well. Conclusions: It is feasible to dynamically adjust the collimator angle during VMAT treatment delivery to correct for prostate rotations. This technique can safely correct for left-right prostate rotations up to 15°.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Trajectory Modulated Arc Therapy: A Fully Dynamic Delivery With Synchronized Couch and Gantry Motion Significantly Improves Dosimetric Indices Correlated With Poor Cosmesis in Accelerated Partial Breast Irradiation

Purpose: To develop planning and delivery capabilities for linear accelerator–based nonisocentric trajectory modulated arc therapy (TMAT) and to evaluate the benefit of TMAT for accelerated partial breast irradiation (APBI) with the patient in prone position. Methods and Materials: An optimization algorithm for volumetrically modulated arc therapy (VMAT) was generalized to allow for user-defined nonisocentric TMAT trajectories combining couch rotations and translations. After optimization, XML scripts were automatically generated to program and subsequently deliver the TMAT plans. For 10 breast patients in the prone position, TMAT and 6-field noncoplanar intensity modulated radiation therapy (IMRT) plans were generated under equivalent objectives and constraints. These plans were compared with regard to whole breast tissue volume receiving more than 100%, 80%, 50%, and 20% of the prescription dose. Results: For TMAT APBI, nonisocentric collision-free horizontal arcs with large angular span (251.5 ± 7.9°) were optimized and delivered with delivery time of ∼4.5 minutes. Percentage changes of whole breast tissue volume receiving more than 100%, 80%, 50%, and 20% of the prescription dose for TMAT relative to IMRT were −10.81% ± 6.91%, −27.81% ± 7.39%, −14.82% ± 9.67%, and 39.40% ± 10.53% (P≤.01). Conclusions: This is a first demonstration of end-to-end planning and delivery implementation of a fully dynamic APBI TMAT. Compared with IMRT, TMAT resulted in marked reduction of the breast tissue volume irradiated at high doses.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Limited Impact of Setup and Range Uncertainties, Breathing Motion, and Interplay Effects in Robustly Optimized Intensity Modulated Proton Therapy for Stage III Non-small Cell Lung Cancer

Purpose: To investigate the impact of setup and range uncertainties, breathing motion, and interplay effects using scanning pencil beams in robustly optimized intensity modulated proton therapy (IMPT) for stage III non-small cell lung cancer (NSCLC). Methods and Materials: Three-field IMPT plans were created using a minimax robust optimization technique for 10 NSCLC patients. The plans accounted for 5- or 7-mm setup errors with ±3% range uncertainties. The robustness of the IMPT nominal plans was evaluated considering (1) isotropic 5-mm setup errors with ±3% range uncertainties; (2) breathing motion; (3) interplay effects; and (4) a combination of items 1 and 2. The plans were calculated using 4-dimensional and average intensity projection computed tomography images. The target coverage (TC, volume receiving 95% of prescribed dose) and homogeneity index (D{sub 2} − D{sub 98}, where D{sub 2} and D{sub 98} are the least doses received by 2% and 98% of the volume) for the internal clinical target volume, and dose indexes for lung, esophagus, heart and spinal cord were compared with that of clinical volumetric modulated arc therapy plans. Results: The TC and homogeneity index for all plans were within clinical limits when considering the breathing motion and interplay effects independently. The setup and range uncertainties had a larger effect when considering their combined effect. The TC decreased to <98% (clinical threshold) in 3 of 10 patients for robust 5-mm evaluations. However, the TC remained >98% for robust 7-mm evaluations for all patients. The organ at risk dose parameters did not significantly vary between the respective robust 5-mm and robust 7-mm evaluations for the 4 error types. Compared with the volumetric modulated arc therapy plans, the IMPT plans showed better target homogeneity and mean lung and heart dose parameters reduced by about 40% and 60%, respectively. Conclusions: In robustly optimized IMPT for stage III NSCLC, the setup and range uncertainties, breathing motion, and interplay effects have limited impact on target coverage, dose homogeneity, and organ-at-risk dose parameters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Numerical and experimental analysis of mechanically induced failure in electric vehicle battery modules

Mitigating thermal runaway and cell-to-cell propagation is essential for improving the safety of electric and hybrid vehicles. Enhancing digital twin capabilities to predict battery mechanical abuse is particularly critical for automotive and aerospace applications, where crashworthiness is a key concern. Understanding failure conditions and propagation in battery modules during mechanical abuse is complex due to interactions between structural deformation, heat transfer, electrochemical processes, exothermic reactions and mechanical fracture. While prior studies have focused on modeling cell-level behavior, extending these models to module or pack level is necessary for a system level understating of electric vehicle safety. This study develops coupled large deformation finite element models that simultaneously solve for electrochemistry, material failure, internal short circuit and thermal runaway propagation. The models account for mechanical and thermal interactions between lithium-ion cells and other battery components while the contact interfaces are evolving with time. Model-predicted voltage, temperature and force responses are compared with experimental data for validation. The results demonstrate that the approach captures key failure mechanisms, including thermal propagation through heat transfer, electrical propagation from short circuits in parallel-connected cells, and mechanical propagation via penetration and crack formation. These findings show that computational models are valuable tools for understanding battery module failure and providing insight that can reduce the need for extensive experimental testing.

25 ENERGY STORAGE↗

Cooperative effect of monoclinic distortion and sinusoidal modulation in the martensitic structure of Ni{sub 2}FeGa

The structural features of the '5M' martensitic phase in Ni{sub 2}FeGa alloys have been determined by electron diffraction using the multi-slice least-squares (MSLS) method. The results demonstrate that the '5M' phase contains an evident cooperative effect of monoclinic distortion and sinusoidal modulation along the [110]{sub c} direction. Theoretical simulations based on our refined data suggest that the '5M' martensitic phase observed in Ni-Fe-Ga and Ni-Mn-Ga has visible common behaviors in both stacking sequence and local structural distortion. Considering the cooperative effect of monoclinic distortion and sinusoidal modulation, we demonstrate that the '7M' martensitic phase could adopt two equivalent structural phases corresponding with the stacking sequences of (43{sup -}){sub 2} and (52{sup -}){sub 2}, respectively. - Graphical abstract: The structural model of the '5M' Ni{sub 2}FeGa martensite viewed along the [001]{sub c} (i.e. [010]{sub m}) zone axis, demonstrating the cooperative effect of monoclinic distortion and sinusoidal modulation along the [110]{sub c} direction.

36 MATERIALS SCIENCE↗

Phosphate modulated luminescence in lanthanum vanadate nanorods- Catechin, polyphenolic ligand

Rare earth orthovanadates and phosphates offer a very high opportunity for fabrication of nanoscale devices that exploit their luminescence properties. Optimization of luminescence by way of modulation of size, shape, structure, and morphology has been an area of study for several researchers. There has been a debate as to whether doped orthophosphate or orthovanadate is better luminescent material as both are chemically similar. It has been reported earlier that catechin hydrate can play the role of a structure director and thus influence the luminescence properties of orthovanadates. In this work, a catechin modulated the synthesis of Eu-doped lanthanum orthophosphate by phosphate substitution into vanadate host lattice is reported. A mechanistic understanding of the luminescence changes in LaMO{sub 4} has been proposed. During the substitution of V with P, catechin modulates the structure between 1D nanorods and nanowires. The host crystal structure, shape, and size influence the luminescence properties in doped LaMO{sub 4}. - Graphical abstract: Schematic illustration for the formation process of LAP nanowires using catechin. Display Omitted - Highlights: • Lanthanum phosphate nanowires are prepared by catechin -natural product. • Morphology tuned from nanorods to nanowires with tune in host lattice. • Quenching of luminescence – Zeolite water and Eu{sup 3+} to Eu{sup 2+} reduction. • The crystal structures was investigated by XRD, NMR, XPS and EPR.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microstructure characterization of the non-modulated martensite in Ni-Mn-Ga alloy

The microstructure of the non-modulated martensite in a Ni-Mn-Ga alloy has been characterized in detail by conventional transmission electron microscopy. Bright field images show that the martensite exhibits an internal substructure consisting of a high density of narrow twins. Using electron diffraction, it is found that the martensite has a tetragonal crystal structure. The lattice correspondence between the parent phase and the non-modulated martensite is investigated. Furthermore, the four twinning elements describing the microtwinning have been graphically and quantitatively determined. The results indicate that the microtwinning within the non-modulated martensite belongs to the compound type.

36 MATERIALS SCIENCE↗

A novel research approach on the dynamic properties of photogenerated charge carriers at Ag{sub 2}S quantum-dots-sensitized TiO{sub 2} films by a frequency-modulated surface photovoltage technology

Graphical abstract: The changed SPV with chopping frequencies indicate the separation speeds of photogenerated charge carriers in different films. - Highlights: • Ag{sub 2}S-sensitized TiO{sub 2} films show good photoelectric responses in visible-light region. • Frequency-modulated SPV give dynamic information and evidence of Ag{sub 2}S QDSSCs’ performance. • Frequency-modulated SPV can supply complementary information in the study of Ag{sub 2}S ODSSCs. - Abstract: Ag{sub 2}S quantum-dots-sensitized TiO{sub 2} films with different amount of Ag{sub 2}S were fabricated by a successive ionic layer adsorption and reaction (SILAR) method. The separation and transport of photogenerated charge carriers at different spectral regions were studied by the frequency-modulated surface photovoltage technology. Some novel dynamic information of photogenerated charge carriers in a wide spectral range is found. The results indicate that the rate and direction of separation (diffusion) for photogenerated charge carriers are closely related to the performance of quantum-dots-sensitized solar cells (QDSSCs) based on the Ag{sub 2}S/TiO{sub 2} nano-structure.

36 MATERIALS SCIENCE↗

Modulating domain structures in Al2O3-based oxide heterostructures

Highlights: • The trigonal-structure Al{sub 2}O{sub 3} nanotubes and orthorhombic-structure Al{sub 2}O{sub 3} nanosheets are successfully synthesized under high temperature and analyzed based on the electron microscopy. • More importantly, the unexpected Mg-Al-O/Al{sub 2}O{sub 3} heterostructures nucleate, whereas the orthorhombic-structure Al{sub 2}O{sub 3} can effectively modulate the occurrence of monoclinic domains in Mg-Al-O. • This work may provide a meaningful insight for growing specific epitaxial films with suitable alumina substrate. - Abstract: Metal oxide has been the focus of research for decades. In this work, besides the trigonal-structure Al{sub 2}O{sub 3} nanotubes and orthorhombic-structure Al{sub 2}O{sub 3} nanosheets, novel Mg-Al-O/Al{sub 2}O{sub 3} heterostructure nanowires were successfully synthesized at high temperature. The structural characteristics of these oxides were investigated based on electron microscopy and group theory analysis. More importantly, it was found that incorporating the orthorhombic-structure Al{sub 2}O{sub 3} could effectively modulate the occurrence of monoclinic domains and thus the related properties of Mg-Al-O/Al{sub 2}O{sub 3} heterostructures. This work provides a reference for understanding and modulating the complex structures with multiple domain variants in Mg-Al-O oxides.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Assessing the feasibility of volumetric-modulated arc therapy using simultaneous integrated boost (SIB-VMAT): An analysis for complex head-neck, high-risk prostate and rectal cancer cases

Intensity-modulated radiotherapy (IMRT) allowed the simultaneous delivery of different doses to different target volumes within a single fraction, an approach called simultaneous integrated boost (SIB). As consequence, the fraction dose to the boost volume can be increased while keeping low doses to the elective volumes, and the number of fractions and overall treatment time will be reduced, translating into better radiobiological effectiveness. In recent years, volumetric-modulated arc therapy (VMAT) has been shown to provide similar plan quality with respect to fixed-field IMRT but with large reduction in treatment time and monitor units (MUs) number. However, the feasibility of VMAT when used with SIB strategy has few investigations to date. We explored the potential of VMAT in a SIB strategy for complex cancer sites. A total of 15 patients were selected, including 5 head-and-neck, 5 high-risk prostate, and 5 rectal cancer cases. Both a double-arc VMAT and a 7-field IMRT plan were generated for each case using Oncentra MasterPlan treatment planning system for an Elekta Precise linac. Dosimetric indexes for targets and organs at risk (OARs) were compared based on dose-volume histograms. Conformity index, homogeneity index, and dose-contrast index were used for target analyses. The equivalent uniform doses and the normal tissue complication probabilities were calculated for main OARs. MUs number and treatment time were analyzed to score treatment efficiency. Pretreatment dosimetry was performed using 2-dimensional (2D)-array dosimeter. SIB-VMAT plans showed a high level of fluence modulation needed for SIB treatments, high conformal dose distribution, similar target coverage, and a tendency to improve OARs sparing compared with the benchmark SIB-IMRT plans. The median treatment times reduced from 13 to 20 minutes to approximately 5 minutes for all cases with SIB-VMAT, with a MUs reduction up to 22.5%. The 2D-array ion-chambers' measurements reported an agreement of more than 95% for a criterion of 3% to 3 mm. SIB-VMAT was able to combine the advantages of conventional SIB-IMRT with its highly conformal dose distribution and OARs sparing and the advantages of 3D-conformal radiotherapy with its fast delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

External beam planning module of Eclipse for external beam radiation therapy

Eclipse is a 3-dimensional (3D) treatment planning system for radiation therapy offered by Varian Medical Systems, Inc. The system has the network connectivity for the electronic transfer of image datasets and digital data communication among different equipment. The scope of this project for this special issue of Medical Dosimetry on 3D treatment planning systems is the assessment of planning tools in the external beam planning module of Eclipse to generate optimized treatment plans for patients undergoing external beam radiation therapy. This treatment planning system is relatively mature to be able to generate (1) simple treatment plans, (2) conformal radiation therapy plans, (3) static intensity-modulated radiation therapy (IMRT) plans, (4) volumetric-modulated arc therapy (VMAT) plans, and (5) treatment plans for electron beam therapy. The treatment planning tools are relatively plentiful to assist in the radiation therapy treatment planning. Some new features have been incorporated in the latest version and are helpful for making high-quality treatment plans. However, the location of the tools is not intuitive, and hence, familiarity with the user interface is essential to the efficient use of the treatment planning system. In addition, there are a number of dose algorithms available for the computation of dose distributions. The understanding of each dose computation algorithm is essential for the optimal use of this treatment planning system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High performance thermoelectric module through isotype bulk heterojunction engineering of skutterudite materials

We demonstrate filled CoSb 3 skutterudite materials with excellent thermoelectric (TE) performance that results in one of the highest reported single stage module efficiency. Here, the improvement in TE material performance was obtained by creating isotype n/n “bulk heterojunction” structure through assembly of novel skutterudite nanocrystals with different Yb-doping content. Combination of significant increase in carrier transport through heterojunction structure and reduction in long-range acoustic phonon transmission by two-phase mixture resulted in enhanced power factor and reduced lattice thermal conductivity. As a result, the figure-of-merit (zT) of heterojunction TE material is improved by more than 35% compared with pristine single homogeneous material. Using these improved TE materials, a high module conversion efficiency of ~9.15% was obtained when operating between 650 °C and 50 °C. This is one of the highest conversion efficiency among the practically measured single stage modules.

42 ENGINEERING↗

Field testing of a spectrum-splitting transmissive concentrator photovoltaic module

Hybrid photovoltaic-thermal systems can decouple IR light from visible light, allowing it to be collected separately by spectrum-optimized mechanisms for increased total efficiency. To demonstrate this, we have designed and prototyped a transmissive spectrum-splitting concentrator photovoltaic module that maximizes solar energy conversion by utilizing the entire solar spectrum. The system first collects visible light using IR-transmissive triple-junction photovoltaic cells to achieve an in-band module efficiency of η m I B = 34.7% for light of wavelengths λ < 870 nm. Simultaneously, 58.8% of light with λ > 870 nm is transmitted through the cells for collection by a thermal receiver. By combining electrical and thermal power collection, 75% of incident solar power is collected, far surpassing the collection capability of only photovoltaics. The module was tested on a dual-axis tracked parabolic concentrator dish at up to 160 suns for 60 cumulative on-sun hours while maintaining photovoltaic cell temperatures at an average of 50 °C via active cooling. The system performed as expected based on modeled values, and represents a cost-effective path forward for dual-generation of electricity and high-temperature heat with increased total efficiency. The capability is valuable in a wide range of commercial and industrial cogeneration applications.

14 SOLAR ENERGY↗

Performance of a silicon photovoltaic module under enhanced illumination and selective filtration of incoming radiation with simultaneous cooling

A promising option to reduce the cost of silicon photovoltaic systems is to concentrate the sunlight incident on the solar cells to increase the output power. However, this leads to higher module temperatures which affects performance adversely and may also cause long term damage. Proper cooling is therefore necessary to operate the system under concentrated radiation. The present work was undertaken to circumvent the problem in practical manner. A suitable liquid, connected to a heat exchanger, was placed in the housing of the photovoltaic module and unwanted wavelengths of solar radiation were filtered out to minimise overheating of the cells. The selection of the liquid was based on factors such as boiling point, transparency towards visible radiation, absorption of infrared and ultraviolet radiation, stability, flow characteristics, heat transfer properties, and electrical nonconductivity. Using a square parabolic type reflector, more than two fold increase in output power was realised on a clear sunny day employing a 0.13 m{sup 2} silicon solar module. Without the cooling arrangement the panel temperature rose uncontrollably. (author)

14 SOLAR ENERGY↗

Microstructure and Composition of Passivating Interfaces in Silicon Heterojunction Solar Modules Weathered in Different Climates

Sanyo/Panasonic patented silicon heterojunction with intrinsic thin layer (HIT) solar cells in the 1990's, which demonstrated world record photovoltaic (PV) efficiency around 2014 and inspired the newer generations of silicon heterojunction technology (SHJ) as well as the current world record back-contact PV cell designs. The high-quality passivation strategy, utilizing ultra-thin layers of hydrogenated amorphous silicon (a-Si:H), leads to high voltages and long carrier lifetimes, but these qualities may degrade over time as the modules operate outdoors. Here, we investigate local microstructure and composition at the interface layers of cells from HIT modules weathered in a hot, humid climate (Florida, USA) and temperate climate (Colorado, USA) for 10 years. We employ a comprehensive set of high-resolution electron microscopy imaging and spectroscopy to directly resolve structure and composition in these cells down to the nanoscale. We show features such as alignment of the In2O3 transparent conducting oxide and a-Si:H layers on the textured c-Si facets, interfacial oxidation at the a-Si:H/c-Si and In2O3/a-Si:H interfaces, and twinned c-Si resulting from epitaxial growth into the a-Si:H layer. Our results raise potential degradation mechanisms in these outdoor-weathered modules, but the root cause of electrical loss remains uncertain due to the very small changes in aged samples. This study shows that many atomic scale features at the In2O3/a-Si:H/c-Si interfaces are surprisingly robust, and the electrical losses with aging may either be attributed to other pathways or be very sensitive to the subtle chemical and microstructural features observed here.

14 SOLAR ENERGY↗