Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Estimating the value of jointly optimized electric power generation and end use: a study of ISO-scale load shaping applied to the residential building stock

A generation-to-load simulation estimated the impact, in terms of production costs and CO2 emissions, attributable to the joint optimization of electric power generation and flexible end uses to support increasing penetrations of renewable energy. Newly conceived, evaluated, and foundational in developing a U.S. National Standard was a transaction-less yet continuous demand response system based on a day-ahead optimum load shape (OLS) designed to encourage Internet-connected devices to autonomously and voluntarily explore options to favour lowest cost generators - without requiring two-way communications, personally identifiable information, or customer opt-in. Boundary conditions used for model calibration included historical weather, residential building stock construction attributes, home appliance and device empirical operating schedules, prototypical power distribution feeder models, thermal generator heat rates, startup and ramping constraints, and fuel costs. Results of an hourly-based annual case study of Texas indicate a 1/3 reduction in production costs and a 1/5 reduction in CO2 emissions are possible.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Evaluation of Counter-Based Dynamic Load Balancing Schemes for Massive Contingency Analysis with Different Computing Environments

Contingency analysis is a key function in the Energy Management System (EMS) to assess the impact of various combinations of power system component failures based on state estimation. Contingency analysis is also extensively used in power market operation for feasibility test of market solutions. High performance computing holds the promise of faster analysis of more contingency cases for the purpose of safe and reliable operation of today’s power grids with less operating margin and more intermittent renewable energy sources. This paper evaluates the performance of counter-based dynamic load balancing schemes for massive contingency analysis under different computing environments. Insights from the performance evaluation can be used as guidance for users to select suitable schemes in the application of massive contingency analysis. Case studies, as well as MATLAB simulations, of massive contingency cases using the Western Electricity Coordinating Council power grid model are presented to illustrate the application of high performance computing with counter-based dynamic load balancing schemes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A 4 kV/120 A SiC Solid-State DC Circuit Breaker Powered By a Load-Independent IPT System

This article introduces a 4 kV/120 A solid-state dc circuit breaker (DCCB) based on discrete SiC mosfets. The DCCB is designed in a five-layer tower structure. Each layer consists of a circular main conduction branch and an attached gate driver. There are two primary benefits of the proposed DCCB. First, it reduces conduction loss with multiple devices in parallel. Second, it achieves an ultrafast response speed with SiC mosfets. Moreover, the gate drivers of the DCCB are powered by a domino inductive power transfer (IPT) system. It achieves the load-independent constant-voltage output characteristics, which means the outputs are immune to load variations. Additionally, an IPT system prototype is implemented to test the power transfer performance. At 500-kHz frequency, the total output power reaches 15.73 W, which is sufficient to power on five gate drivers, with a peak transfer efficiency of 75.4%. The IPT system is tested to power a 4 kV/120 A DCCB prototype. It validates that the DCCB is effective to turn off 120 A current within 3.5 μs.

42 ENGINEERING↗

Semi-Supervised, Non-Intrusive Disaggregation of Nodal Load Profiles With Significant Behind-the-Meter Solar Generation

It is of imperative interests for regional transmission organizations (RTOs) to effectively extract actual load profiles at transmission nodes with significant behind-the-meter solar generation, which remains a gap in the existing technology paradigm. This paper proposes an explicit yet efficient linear estimator to disaggregate actual load profiles at transmission buses with significant behind-the-meter (BTM) solar generations. The proposed estimator is based on disaggregating (i.e., extracting) at locations close to transmission buses under consideration. Further, to overcome the lack of “ground truth” and validate the performance of the proposed algorithms, we first propose semi-supervised mechanisms with parameter tuning as well as unsupervised clustering and leverage the unique characteristics of zero-crossing points in BTM solar peaking behaviors, which we refer to as “Zone-to-Node (Z2N)” methods. Next, we further propose a bi-level Node-to-Node (N2N) framework that improves the overall disaggregation performances compared to Z2N. Numerical results are presented using real-world data at PJM Interconnection.

14 SOLAR ENERGY↗

Descriptive Analytics-Based Anomaly Detection for Cybersecure Load Forecasting

As power delivery systems evolve and become increasingly reliant on accurate forecasts, they will be more and more vulnerable to cybersecurity issues. A coordinated data attack by sophisticated adversaries can render existing data corrupt or outlier detection methods ineffective. This would have a very negative impact on operational decisions. The focus of this paper is to develop descriptive analytics-based methods for anomaly detection to protect the load forecasting process against cyberattacks to essential data. We propose an integrated solution (IS) and a hybrid implementation of IS (HIIS) that can detect and mitigate cyberattack induced long sequence anomalies. HIIS is also capable of improving true positive rates and reducing false positive rates significantly comparing with IS. The proposed HIIS can serve as an online cybersecure load forecasting scheme.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Effect of Cyclic Loading on the Size of Coherent Scattering Regions of X-Ray Radiation in Crystalline Samples

The effect of cyclic loading on the magnitude of coherent scattering regions (CSR) of X-ray radiation and microstresses of the II type in various crystalline materials: semiconductor (samarium sulfide) and metal (steel, duralumin) has been found. The loading was carried out by compressing the samples in various ways: all-round, uniaxial, bending compression. It is shown that with an increase in the number of compression cycles, the CSR values in all cases decrease, and the microstresses increase. These values can serve as parameters to assess the degree of mechanical fatigue of the material.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Joint Effect of Small Additives of Carbon Nanoparticles of Different Morphologies on the Mechanical Characteristics of Cross-Linked Polyurethanes under Static and Dynamic Loads

Influence of small additives of fullerene, graphene oxide, and their combinations in the ratio of 85 : 15 on the structure and mechanical properties of cross-linked polyurethanes under static and dynamic loads has been investigated. Nanocomposite structures have been studied by X-ray diffraction analysis and scanning electron microscopy. It is shown that the presence of carbon nanoparticles in the composite reduces its strength under both static and shock-wave loads. The synergistic effect of the mixture of carbon nanoparticles manifests itself as an increase in the elastic modulus by a factor of 1.25 in comparison with the initial polymer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Plug and Process Loads Capacity and Power Requirements Analysis

This report addresses gaps in actionable knowledge that would help reduce the plug load capacities designed into buildings. Prospective building occupants and real estate brokers lack accurate references for plug and process load (PPL) capacity requirements, so they often request 5-10 W/ft2 in their lease agreements. Limited initial data, however, suggest that actual PPL densities in leased buildings are substantially lower. Overestimating PPL capacity leads designers to oversize electrical infrastructure and cooling systems. Better guidance will enable improved sizing and design of these systems, decrease upfront capital costs, and allow systems to operate more energy efficiently. The main focus of this report is to provide industry with reliable, objective third-party guidance to address the information gap in typical PPL densities for commercial building tenants. This could drive changes in negotiations about PPL energy demands.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analyzing Design Heating Loads in Superinsulated Buildings

The U.S. Department of Energy’s Building America research team Consortium for Advanced Residential Buildings (CARB) worked with the EcoVillage cohousing community in Ithaca, New York, on the Third Residential EcoVillage Experience neighborhood. This communityscale project consists of 40 housing units—15 apartments and 25 single-family residences. Units range in size from 450 ft2 to 1,664 ft2 and cost from $80,000 for a studio apartment to $235,000 for a three- or four-bedroom single-family home. For the research component of this project, CARB analyzed current heating system sizing methods for superinsulated homes in cold climates to determine if changes in building load calculation methodology should be recommended. Actual heating energy use was monitored and compared to results from the Air Conditioning Contractors of America’s Manual J8 (MJ8) and the Passive House Planning Package software. Results from that research indicate that MJ8 significantly oversizes heating systems for superinsulated homes and that thermal inertia and internal gains should be considered for more accurate load calculations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Load Participation in Ancillary Services

Of five basic types of load response (participation), DOE load participation in ancillary services workshop focused on bulk power system reliability services regulation response and spinning reserve.

DOE load participation in ancillary services↗

Analyzing Design Heating Loads in Superinsulated Buildings

Super-insulated homes offer many benefits including improved comfort, reduced exterior noise penetration, lower energy bills, and the ability to withstand power and fuel outages under much more comfortable conditions than a typical home. While these homes aren't necessarily constructed with excessive mass in the form of concrete floors and walls, the amount of insulation and the increase in the thickness of the building envelope can lead to a mass effect, resulting in the structures ability to store much more heat than a code built home. This results in a very low thermal inertia making the building much less sensitive to drastic temperature swings thereby decreasing the peak heating load demand. During the winter of 2013/2014, CARB monitored the energy use of three homes in climate zone 6 in an attempt to evaluate the accuracy of two different mechanical system sizing methods for low load homes. Based on the results, it is recommended that internal and solar gains be included and some credit for thermal inertia be used in sizing calculations for super insulated homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hardware Implementation and Market Impacts of Grid-Supportive Functions in End-Use Loads

Grid-supportive loads (GSLs) are power electronics-based end-use loads that can provide frequency response and other grid services by autonomously adjusting their output power using local grid measurements. This report provides details on GSL hardware design options and their associated costs and benefits for multiple devices, including EV chargers, refrigerators, and heat pumps. We consider mechanisms to incentivize adoption of GSLs at scale and estimate the quantity of frequency response that can be procured with GSLs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Best Practices in Electricity Load Modeling and Forecasting for Long-Term Power System Planning

This document highlights the best practices on data acquisition and management, modeling and stakeholder engagement required for enhanced load modeling and forecasting. Each section is interspersed with case studies to highlight lessons from different country contexts to highlight both cross-cutting and location specific best practices needed to conduct robust load modeling and forecasting.

24 POWER TRANSMISSION AND DISTRIBUTION↗

BuildingsBench: A Large-Scale Dataset of 900K Buildings and Benchmark for Short-Term Load Forecasting

The BuildingsBench datasets consist of: - Buildings-900K: A large-scale dataset of 900K buildings for pretraining models on the task of short-term load forecasting (STLF). Buildings-900K is statistically representative of the entire U.S. building stock. - 7 real residential and commercial building datasets for benchmarking two downstream tasks evaluating generalization: zero-shot STLF and transfer learning for STLF. Buildings-900K can be used for pretraining models on day-ahead STLF for residential and commercial buildings. The specific gap it fills is the lack of large-scale and diverse time series datasets of sufficient size for studying pretraining and finetuning with scalable machine learning models. Buildings-900K consists of synthetically generated energy consumption time series. It is derived from the NREL End-Use Load Profiles (EULP) dataset (see link to this database in the links further below). However, the EULP was not originally developed for the purpose of STLF. Rather, it was developed to "...help electric utilities, grid operators, manufacturers, government entities, and research organizations make critical decisions about prioritizing research and development, utility resource and distribution system planning, and state and local energy planning and regulation." Similar to the EULP, Buildings-900K is a collection of Parquet files and it follows nearly the same Parquet dataset organization as the EULP. As it only contains a single energy consumption time series per building, it is much smaller (~110 GB). BuildingsBench also provides an evaluation benchmark that is a collection of various open source residential and commercial real building energy consumption datasets. The evaluation datasets, which are provided alongside Buildings-900K below, are collections of CSV files which contain annual energy consumption. The size of the evaluation datasets altogether is less than 1GB, and they are listed out below: 1. ElectricityLoadDiagrams20112014 2. Building Data Genome Project-2 3. Individual household electric power consumption (Sceaux) 4. Borealis 5. SMART 6. IDEAL 7. Low Carbon London A README file providing details about how the data is stored and describing the organization of the datasets can be found within each data lake version under BuildingsBench.

Array↗

We Need to Talk... Developing Communicating Power Supplies to Monitor & Control Miscellaneous Electric Loads

Plug loads represent 30percent of total electricity use in residential buildings. Significant energy savings would result from an accurate understanding of which miscellaneous electric devices are using energy, at what time, and in what quantity. Commercially available plug load monitoring and control solutions replace or limit the attached device's native controls - forcing the user to adapt to a separate set of controls associated with the monitoring and control hardware. A better solution is integration of these capabilities at the power supply level. In this paper, we demonstrate a method achieving this integration. Our solution allows unobtrusive power monitoring and control while retaining native device control features. Further, our prototype enables intelligent behaviors by allowing devices to respond to the state of one another automatically. The CPS enables energy savings while demonstrating an added level of functionality to the user. If CPS technology became widespread in devices, a combination of automated and human interactive solutions would enable high levels of energy savings in buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Disaggregating Smart Meter Data to Identify Electric Loads and Control Opportunities

As utility data, such as smart meter data, becomes more broadly available, there is general interest in using it to improve utility operations and enable adoption of other advanced technology - such as solar photovoltaics (PV), energy storage, and controls. We explore one such use case - identifying electric resistance water heaters from smart meter data, as well as characterizing their potential for load-shifting to support grid voltage stability under high-penetration PV adoption. This paper shows the limitation of typical 15-minute data, and how shortterm capture of additional 1-minute data is needed to enable the desired application. Results indicate about 4 kWh water heating load can be shifted to align with peak sun hours in a low use home. This methodology is an example, and can be adapted to other grid-integrated efficient building use cases.

14 SOLAR ENERGY↗

Best Practices for Plug Load Management Using a Building Energy Management System

The University of California San Diego (UCSD) successfully integrated PLCs with their BEMS, which resulted in 66% energy savings over one week across 25 plug loads (K. Chia et al. 2023). UCSD documented each step of this effort, highlighting best practices along the way, in their 10-page brief, "Best Practices for Plug Load Management Using a Building Energy Management System" (also referred to as "brief" in this document). This fact sheet provides highlights and key takeaways from UCSD's brief. The reader is encouraged to read UCSD's full brief if they wish to move forward with implementing PLC integration with their BEMS.

Building Energy Management System Integration↗

Dynamic load balancing of matrix-vector multiplications on roadrunner compute nodes

Hybrid architectures that combine general purpose processors with accelerators are being adopted in several large-scale systems such as the petaflop Roadrunner supercomputer at Los Alamos. In this system, dual-core Opteron host processors are tightly coupled with PowerXCell 8i processors within each compute node. In this kind of hybrid architecture, an accelerated mode of operation is typically used to offload performance hotspots in the computation to the accelerators. In this paper we explore the suitability of a variant of this acceleration mode in which the performance hotspots are actually shared between the host and the accelerators. To achieve this we have designed a new load balancing algorithm, which is optimized for the Roadrunner compute nodes, to dynamically distribute computation and associated data between the host and the accelerators at runtime. Results are presented using this approach for sparse and dense matrix-vector multiplications that show load-balancing can improve performance by up to 24% over solely using the accelerators.

97 MATHEMATICS AND COMPUTING↗