Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “leak”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Operation status of the electron cyclotron resonance ion source at Gunma University

An ECR ion source of Gunma University Heavy Ion Medical Center, so-called KeiGM [M. Muramatsu, A. Kitagawa, Y. Sakamoto, S. Sato, Y. Sato, H. Ogawa, S. Yamada, H. Ogawa, Y. Yoshida, and A. G. Drentje, Rev. Sci. Instrum. 76, 113304 (2005)], has been operated for cancer therapy and physical/biological experiment since 2010. KeiGM produces typically 230 μA of 10 keV/u C{sup 4+} ions from CH{sub 4} gases. The vacuum pressure is kept between 1.2 × 10{sup −4} and 1.7 × 10{sup −4} Pa so as to suppress the pulse-to-pulse current fluctuation within ±10%. The extraction electrode is cleaned every 6–8 months in order to remove deposited carbon, which increases the leak current and discharge. In order to investigate the possibility of long-term operation without such maintenances, oxygen aging for the cleaning of the extraction electrode has been tested in the test bench. The same-designed ion sources at National Institute of Radiological Sciences and SAGA Heavy Ion Medical Accelerator in Tosu (SAGA-HIMAT) are also operated with stable C{sup 4+} current, which are suitable for the continuous operation for cancer therapy.

43 PARTICLE ACCELERATORS↗

Q-factor of (In,Ga)N containing III-nitride microcavity grown by multiple deposition techniques

A 3λ/2 (In,Ga)N/GaN resonant cavity, designed for ∼415 nm operation, is grown by molecular beam epitaxy and is sandwiched between a 39.5-period (In,Al)N/GaN distributed Bragg reflector (DBR), grown on c-plane GaN-on-sapphire pseudo-substrate by metal-organic vapor phase epitaxy and an 8-period SiO{sub 2}/ZrO{sub 2} DBR, deposited by electron beam evaporation. Optical characterization reveals an improvement in the cavity emission spectral purity of approximately one order of magnitude due to resonance effects. The combination of spectrophotometric and micro-reflectivity measurements confirms the strong quality (Q)-factor dependence on the excitation spot size. We derive simple analytical formulas to estimate leak and residual absorption losses and propose a simple approach to model the Q-factor and to give a quantitative estimation of the weight of cavity disorder. The model is in good agreement with both transfer-matrix simulation and the experimental findings. We point out that the realization of high Q-factor (In,Ga)N containing microcavities on GaN pseudo-substrates is likely to be limited by the cavity disorder.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

New vertical cryostat for the high field superconducting magnet test station at CERN

In the framework of the R and D program for new superconducting magnets for the Large Hadron Collider accelerator upgrades, CERN is building a new vertical test station to test high field superconducting magnets of unprecedented large size. This facility will allow testing of magnets by vertical insertion in a pressurized liquid helium bath, cooled to a controlled temperature between 4.2 K and 1.9 K. The dimensions of the cryostat will allow testing magnets of up to 2.5 m in length with a maximum diameter of 1.5 m and a mass of 15 tons. To allow for a faster insertion and removal of the magnets and reducing the risk of helium leaks, all cryogenics supply lines are foreseen to remain permanently connected to the cryostat. A specifically designed 100 W heat exchanger is integrated in the cryostat helium vessel for a controlled cooling of the magnet from 4.2 K down to 1.9 K in a 3 m{sup 3} helium bath. This paper describes the cryostat and its main functions, focusing on features specifically developed for this project. The status of the construction and the plans for assembly and installation at CERN are also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Load responsive multilayer insulation performance testing

Cryogenic insulation designed to operate at various pressures from one atmosphere to vacuum, with high thermal performance and light weight, is needed for cryogenically fueled space launch vehicles and aircraft. Multilayer insulation (MLI) performs well in a high vacuum, but the required vacuum shell for use in the atmosphere is heavy. Spray-on foam insulation (SOFI) is often used in these systems because of its light weight, but can have a higher heat flux than desired. We report on the continued development of Load Responsive Multilayer Insulation (LRMLI), an advanced thermal insulation system that uses dynamic beam discrete spacers that provide high thermal performance both in atmosphere and vacuum. LRMLI consists of layers of thermal radiation barriers separated and supported by micromolded polymer spacers. The spacers have low thermal conductance, and self-support a thin, lightweight vacuum shell that provides internal high vacuum in the insulation. The dynamic load responsive spacers compress to support the external load of a vacuum shell in one atmosphere, and decompress under reduced atmospheric pressure for lower heat leak. Structural load testing was performed on the spacers with various configurations. LRMLI was installed on a 400 liter tank and boil off testing with liquid nitrogen performed at various chamber pressures from one atmosphere to high vacuum. Testing was also performed with an MLI blanket on the outside of the LRMLI.

42 ENGINEERING↗

First scientific application of the membrane cryostat technology

We report on the design, fabrication, performance and commissioning of the first membrane cryostat to be used for scientific application. The Long Baseline Neutrino Experiment (LBNE) has designed and fabricated a membrane cryostat prototype in collaboration with IHI Corporation (IHI). Original goals of the prototype are: to demonstrate the membrane cryostat technology in terms of thermal performance, feasibility for liquid argon, and leak tightness; to demonstrate that we can remove all the impurities from the vessel and achieve the purity requirements in a membrane cryostat without evacuation and using only a controlled gaseous argon purge; to demonstrate that we can achieve and maintain the purity requirements of the liquid argon during filling, purification, and maintenance mode using mole sieve and copper filters from the Liquid Argon Purity Demonstrator (LAPD) R and D project. The purity requirements of a large liquid argon detector such as LBNE are contaminants below 200 parts per trillion oxygen equivalent. This paper gives the requirements, design, construction, and performance of the LBNE membrane cryostat prototype, with experience and results important to the development of the LBNE detector.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved light extraction with nano-particles offering directional radiation diagrams

We propose a unique approach for light extraction, using engineered nano-particles to efficiently decouple the light guided in transverse-magnetic guided modes into free-space radiation modes that leak out normally to the thin-film stacks. The underlying mechanism takes advantage of a small electric field variation at the nano-particle scale and induces a “polarization conversion,” which renders the induced dipole moment perpendicular to the polarization of the incident light. Our analysis is supported by 2D fully vectorial computational results. Potential applications for light emitting or photovoltaic devices are outlined.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Controllable generation of reactive oxygen species by femtosecond-laser irradiation

Femtosecond lasers have been advancing Biophotonics research in the past two decades with multiphoton microscopy, microsurgery, and photodynamic therapy. Nevertheless, laser irradiation is identified to bring photodamage to cells via reactive oxygen species (ROS) generation with unclear mechanism. Meanwhile, currently in biological researches, there is no effective method to provide controllable ROS production precisely, which originally is leaked from mitochondria during respiration and plays a key role in a lot of important cellular processes and cellular signaling pathways. In this study, we show the process of how the tightly focused femtosecond-laser induces ROS generation solely in mitochondria at the very beginning and then release to cytosol if the stimulus is intense enough. At certain weak power levels, the laser pulses induce merely moderate Ca{sup 2+} release but this is necessary for the laser to generate ROS in mitochondria. Cellular original ROS are also involved with a small contribution. When the power is above a threshold, ROS are then released to cytosol, indicating photodamage overwhelming cellular repair ability. The mechanisms in those two cases are quite different. Those results clarify parts of the mechanism in laser-induced ROS generation. Hence, it is possible to further this optical scheme to provide controllable ROS generation for ROS-related biological researches including mitochondrial diseases and aging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-κ Al{sub 2}O{sub 3} material in low temperature wafer-level bonding for 3D integration application

This work systematically investigated a high-κ Al{sub 2}O{sub 3} material for low temperature wafer-level bonding for potential applications in 3D microsystems. A clean Si wafer with an Al{sub 2}O{sub 3} layer thickness of 50 nm was applied as our experimental approach. Bonding was initiated in a clean room ambient after surface activation, followed by annealing under inert ambient conditions at 300 °C for 3 h. The investigation consisted of three parts: a mechanical support study using the four-point bending method, hermeticity measurements using the helium bomb test, and thermal conductivity analysis for potential heterogeneous bonding. Compared with samples bonded using a conventional oxide bonding material (SiO{sub 2}), a higher interfacial adhesion energy (∼11.93 J/m{sup 2}) and a lower helium leak rate (∼6.84 × 10{sup −10} atm.cm{sup 3}/sec) were detected for samples bonded using Al{sub 2}O{sub 3}. More importantly, due to the excellent thermal conductivity performance of Al{sub 2}O{sub 3}, this technology can be used in heterogeneous direct bonding, which has potential applications for enhancing the performance of Si photonic integrated devices.

36 MATERIALS SCIENCE↗

Electronic transport transition at graphene/YBa{sub 2}Cu{sub 3}O{sub 7−δ} junction

We report the fabrication of graphene/YBa{sub 2}Cu{sub 3}O{sub 7−δ} contacts and their superconducting proximity effect. Both the temperature dependence of resistance and the current bias dependence of resistance for the contacts are investigated, respectively. The results are compared with that of pure YBCO Hall bar. It is found that the differential resistance transits from a non-zero value to zero at high bias across graphene/YBCO junction below the transition temperature of YBCO, the phenomena indicate the tunneling of Cooper pairs from YBCO to graphene. As the YBCO film deposited by pulsed laser deposition has a rough surface, the graphene layer can contact with the edge of CuO{sub 2} planes. It allows that Cooper pairs could leak into graphene along the CuO{sub 2} planes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-pressure cell for neutron diffraction with in situ pressure control at cryogenic temperatures

Pressure generation at cryogenic temperatures presents a problem for a wide array of experimental techniques, particularly neutron studies due to the volume of sample required. We present a novel, compact pressure cell with a large sample volume in which load is generated by a bellow. Using a supply of helium gas up to a pressure of 350 bar, a load of up to 78 kN is generated with leak-free operation. In addition, special fiber ports added to the cryogenic center stick allow for in situ pressure determination using the ruby pressure standard. Mechanical stability was assessed using finite element analysis and the dimensions of the cell have been optimized for use with standard cryogenic equipment. Load testing and on-line experiments using NaCl and BiNiO{sub 3} have been done at the WISH instrument of the ISIS pulsed neutron source to verify performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Describing long-range charge-separation processes with subsystem density-functional theory

Long-range charge-transfer processes in extended systems are difficult to describe with quantum chemical methods. In particular, cost-effective (non-hybrid) approximations within time-dependent density functional theory (DFT) are not applicable unless special precautions are taken. Here, we show that the efficient subsystem DFT can be employed as a constrained DFT variant to describe the energetics of long-range charge-separation processes. A formal analysis of the energy components in subsystem DFT for such excitation energies is presented, which demonstrates that both the distance dependence and the long-range limit are correctly described. In addition, electronic couplings for these processes as needed for rate constants in Marcus theory can be obtained from this method. It is shown that the electronic structure of charge-separated states constructed by a positively charged subsystem interacting with a negatively charged one is difficult to converge — charge leaking from the negative subsystem to the positive one can occur. This problem is related to the delocalization error in DFT and can be overcome with asymptotically correct exchange–correlation (XC) potentials or XC potentials including a sufficiently large amount of exact exchange. We also outline an approximate way to obtain charge-transfer couplings between locally excited and charge-separated states.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-precision thermal and electrical characterization of thermoelectric modules

This paper describes an apparatus for performing high-precision electrical and thermal characterization of thermoelectric modules (TEMs). The apparatus is calibrated for operation between 20 °C and 80 °C and is normally used for measurements of heat currents in the range 0–10 W. Precision thermometry based on miniature thermistor probes enables an absolute temperature accuracy of better than 0.010 °C. The use of vacuum isolation, thermal guarding, and radiation shielding, augmented by a careful accounting of stray heat leaks and uncertainties, allows the heat current through the TEM under test to be determined with a precision of a few mW. The fractional precision of all measured parameters is approximately 0.1%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a magnetic shielding system for the time of flight enhanced diagnostics neutron spectrometer at Experimental Advanced Superconducting Tokamak

The novel neutron spectrometer TOFED (Time of Flight Enhanced Diagnostics), comprising 90 individual photomultiplier tubes coupled with 85 plastic scintillation detectors through light guides, has been constructed and installed at Experimental Advanced Superconducting Tokamak. A dedicated magnetic shielding system has been constructed for TOFED, and is designed to guarantee the normal operation of photomultiplier tubes in the stray magnetic field leaking from the tokamak device. Experimental measurements and numerical simulations carried out employing the finite element method are combined to optimize the design of the magnetic shielding system. The system allows detectors to work properly in an external magnetic field of 200 G.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dry demagnetization cryostat for sub-millikelvin helium experiments: Refrigeration and thermometry

We demonstrate successful “dry” refrigeration of quantum fluids down to T = 0.16 mK by using copper nuclear demagnetization stage that is pre-cooled by a pulse-tube-based dilution refrigerator. This type of refrigeration delivers a flexible and simple sub-mK solution to a variety of needs including experiments with superfluid {sup 3}He. Our central design principle was to eliminate relative vibrations between the high-field magnet and the nuclear refrigeration stage, which resulted in the minimum heat leak of Q = 4.4 nW obtained in field of 35 mT. For thermometry, we employed a quartz tuning fork immersed into liquid {sup 3}He. We show that the fork oscillator can be considered as self-calibrating in superfluid {sup 3}He at the crossover point from hydrodynamic into ballistic quasiparticle regime.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The status and prospective of environmental radiation monitoring stations in Saudi Arabia

The use of nuclear technology requires an environmental monitoring program to ensure the safety of the environment, and to protect people from the hazards of radioactive materials, and nuclear accidents. Nuclear accidents are unique, for they incur effects that surpass international frontiers, and can even have a long lasting impact on Earth. Such was the case of the Chernobyl accident in the Ukraine on April 6, 1986. For that purpose, international and national efforts come together to observe for any nuclear or radioactive accident. Many states, including Saudi Arabia which oversees the operation of the National Radiation, Environmental and Early Monitoring Stations, The Radiation Monitoring Stations(RMS’s) are currently scattered across 35 cities in the country,. These locations are evaluated based on various technological criteria such as border cities, cities of high population density, wind direction, etc. For new nuclear power plants hovering around, it is strongly recommended to increase the number of radiation monitoring stations to warn against any threat that may arise from a nuclear leak or accident and to improve the performance of the existing RMS’s. SARA (Spectroscopic Monitoring Station for air) should be implemented due to the high sensitivity to artificial radiation, automatic isotope identification, free of maintenance, and fully independent due to solar power supply (incl. battery backup) and wireless communication (GPRS)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Ka-band TM{sub 02} mode relativistic backward wave oscillator with cascaded resonators

By combining the Cerenkov-type generator with the cascaded resonators, this paper proposes a Ka-band relativistic backward wave oscillator operating under the guide magnetic field 1.0 T with high power handling capability and high conversion efficiency. It is found that TM{sub 02} can be selected as the operation mode in order to increase the power handling capability and provide sufficient coupling with the electron beam. In slow wave structure (SWS), ripples composed of semicircle on top of the rectangle enhance the wave-beam interaction and decrease the intensity of the electric field on the metallic surface. Taking advantage of the resonator cascades, the output power and the conversion efficiency are promoted greatly. The front cascaded resonators efficiently prevent the power generated in SWS from leaking into the diode region, and quicken the startup of the oscillation due to the premodulation of the beam. However, the post cascade slightly postpones the startup because of the further energy extraction from the electron beam. The numerical simulation shows that generation with power 514 MW and efficiency 41% is obtained under the diode voltage 520 kV and current 2.4 kA. And the microwave with the pure frequency spectrum of 29.35 GHz radiates in the pure TM{sub 01} mode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fabrication and characterization of photovoltaic devices based on perovskite compounds with TiO{sub 2} nanoparticles

Perovskite-type photovoltaic devices were fabricated by a spin-coating method using a mixture solution. The compact and meso-porous TiO{sub 2} of the solar cells were fabricated from TiO{sub 2} nanoparticles and sol, and the photovoltaic properties and microstructures were characterized. The conversion efficiencies were improved by the combination of TiO{sub 2} nanoparticles and sol. Current density was also improved by increasing numbers of spin-coatings of meso-porous TiO{sub 2}. Thick meso-porous TiO2 layers would assist the construction of perovskite layers and block of the leak current.

36 MATERIALS SCIENCE↗

Review of disaster management implementation for the community safety in the vicinity of oil and gas field

Sukowati site which is operated by Production Sharing Contract (PSC) Joint Operating Body Pertamina Petrochina East Java (JOB P-PEJ) located at Bojonegoro regency East Java Province. This site is close to densely populated settlements with approximately 6,010 people within a radius less than 600 m. The fluid produced have a dangerous potential to the above mention community, due to accompanying of hydrogen sulphide gas (H2S) with a concentration about 0.6% – 2% from the total gas produced. In 2006, there was incident of gas leak from drilling development well of Sukowati # 5. The incident made the surrounding community panic due to lack of preparedness and awareness. Learning from the incident, the company together with the government and local communities initiated to make improvements through the disaster management system approach. The efforts are carried out in accordance with the 4 (four) periods in a continuous cycle consist of (1) mitigation; (2) preparation; (3) response and (4) recovery. Emergency response drills conducted regularly at least once a year, its main purpose is to find out the results of the implementation of the existing disaster management. The results of the drills showed an increase in public awareness and responsiveness to emergency situations caused by the operational failures of oil and gas exploration and production activities near their settlement.

54 ENVIRONMENTAL SCIENCES↗