Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “injection flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Manufacturing control systems and logic for prognosis of defects in composite materials

Presented are manufacturing control systems for composite-material structures, methods for assembling/operating such systems, and transfer molding techniques for predicting and ameliorating void conditions in fiber-reinforced polymer panels. A method for forming a composite-material construction includes receiving a start signal indicating a fiber-based preform is inside a mold cavity, and transmitting a command signal to inject pressurized resin into the mold to induce resin flow within the mold cavity and impregnate the fiber-based preform. An electronic controller receives, from a distributed array of sensors attached to the mold, signals indicative of pressure and/or temperature at discrete locations on an interior face of the mold cavity. The controller determines a measurement deviation between a calibrated baseline value and the pressure and/or temperature values for each of the discrete locations. If any one of the respective measurement deviations exceeds a calibrated threshold, a void signal is generated to flag a detected void condition.

36 MATERIALS SCIENCE↗

Evaluation of Communication Issues in Primal-Dual-Based Distributed Energy Resource Management Systems (DERMS): Preprint

With the increasing adoption of distributed energy resources (DERs) in distribution networks, DERMS is becoming an attractive option to coordinate the control of DERs, especially primal-dual-based DERMS which is a well-developed class of them. In order to help lower the uncertainty in commercializing them, we evaluate and find the upper limits of severity for some common issues that can occur within the communication systems on which a primal-dual-based DERMS relies on; these include packet losses, link failures, and delays. This information can help a DERMS operator decide on the specifications for the communication infrastructure it will invest in for the DERMS. Our evaluation is based on numerical simulations of a real-world feeder with around 2,000 nodes and a DERMS that controls 163 PV generators and 140 energy storage batteries. In general, we found that the DERMS becomes less resistant to communication issues as the information flows closer to the DERs implementing the controllable power injections.

communication delay↗

Waste Encapsulation and Storage Facility Stabilization and Ventilation Project-18121

Department of Energy contractor CH2M HILL Plateau Remediation Company (CH2M) is responsible for the safe and compliant operation of the Waste Encapsulation and Storage Facility (WESF), a nuclear materials storage facility at Hanford containing 1,936 highly radioactive capsules containing cesium and strontium. The capsules are currently stored under approximately 4 m (13 ft) of water. The water shields workers from radiation and helps cool the capsules. WESF is a large, concrete structure nominally 48 m (160 ft) long, 30 m (98 ft) wide and 12 m (40 ft) high with the pool cells being approximately 4 m (13 ft) below grade level. It is a robust facility with walls ranging from 0.3 m to 1 m (1 ft to 3 ft) thick. While the capsules are currently in a safe configuration, WESF is an aging facility, and DOE and CH2M are modifying the facility to ensure continued safe and compliant operations and to support the eventual transfer of capsules to dry storage. Dry storage would eliminate the possibility of a release of radioactive material in the unlikely event of a major earthquake that might result in loss of pool storage water and overheating and breach of one or more capsules. The project was divided into two major deliverables: 1) Ventilation: replacement of the existing ventilation system which included a below-grade high efficiency particulate air (HEPA) filter pit with an above grade HEPA filter skid and new fans and ducting. 2) Stabilization: grouting deactivated facility hot cells and other void spaces to the maximum extent practical to reduce material at risk from legacy contamination. The aging ventilation system relied on HEPA filters that exceeded their operational life. Due to the high levels of radionuclide contamination, replacing the filters was impractical and highly hazardous. CH2M installed a new ventilation system to provide safe and compliant ventilation for future operations. The project used an existing, unused ventilation skid that was designed for another project. Repurposing the unused skid presented additional technical challenges to modify the system for the project specific requirements. The new system is above ground, easier to maintain and is built to current standards. New connections inside the facility were installed to allow the new ventilation to operate effectively. The stabilization project is unique in that core drilling and grouting was performed in an operating Hazard Category 2 nuclear facility, which brought forth safety basis and environmental regulatory challenges. The hot cells were isolated from all existing support utilities including electrical, process chemicals, manipulator ports, instrument air, etc. to seal the hot cells and prevent highly contaminated supernate or grout from leaking into adjacent galleries. A high flow grout was used to maximize the distance between injection ports. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Snowplow Injection Front Effects

As the Polar spacecraft apogee precessed through the magnetic equator in 2001, Polar encountered numerous substorm events in the region between geosynchronous orbit and 10 RE geocentric distance; most of them in the plasma sheet boundary layers. Of these, a small number was recorded near the neutral sheet in the evening sector. Polar/Thermal Ion Dynamics Experiment provides a unique perspective on the lowest-energy ion plasma, showing that these events exhibited a damped wavelike character, initiated by a burst of radially outward flow transverse to the local magnetic field at approximately 80 km/s. They then exhibit strongly damped cycles of inward/outward flow with a period of several minutes. After one or two cycles, they culminated in a hot plasma electron and ion injection, quite similar to those observed at geosynchronous orbit. Cold plasmaspheric plasmas comprise the outward flow cycles, while the inward flow cycles contain counterstreaming field-parallel polar wind-like flows. The observed wavelike structure, preceding the arrival of an earthward moving substorm injection front, suggests an outward displacement driven by the inward motion at local times closer to midnight, that is, a "snowplow" effect. The damped in/out flows are consistent with interchange oscillations driven by the arrival at the observed local time by an injection originating at greater radius and local time.

Substorm↗

Modeling Gas Transport in the Shallow Subsurface During the ZERT CO2 Release Test

We used the multiphase and multicomponent TOUGH2/EOS7CA model to carry out predictive simulations of CO{sub 2} injection into the shallow subsurface of an agricultural field in Bozeman, Montana. The purpose of the simulations was to inform the choice of CO{sub 2} injection rate and design of monitoring and detection activities for a CO{sub 2} release experiment. The release experiment configuration consists of a long horizontal well (70 m) installed at a depth of approximately 2.5 m into which CO{sub 2} is injected to mimic leakage from a geologic carbon sequestration site through a linear feature such as a fault. We estimated the permeability of the soil and cobble layers present at the site by manual inversion of measurements of soil CO{sub 2} flux from a vertical-well CO{sub 2} release. Based on these estimated permeability values, predictive simulations for the horizontal well showed that CO{sub 2} injection just below the water table creates an effective gas-flow pathway through the saturated zone up to the unsaturated zone. Once in the unsaturated zone, CO{sub 2} spreads out laterally within the cobble layer, where liquid saturation is relatively low. CO{sub 2} also migrates upward into the soil layer through the capillary barrier and seeps out at the ground surface. The simulations predicted a breakthrough time of approximately two days for the 100kg d{sup -1} injection rate, which also produced a flux within the range desired for testing detection and monitoring approaches. The seepage area produced by the model was approximately five meters wide above the horizontal well, compatible with the detection and monitoring methods tested. For a given flow rate, gas-phase diffusion of CO{sub 2} tends to dominate over advection near the ground surface, where the CO{sub 2} concentration gradient is large, while advection dominates deeper in the system.

54 ENVIRONMENTAL SCIENCES↗

Modeling of Supersonic Film Cooling on the J-2X Nozzle Extension

Supersonic film cooling (SSFC) of nozzles has been used in several liquid rocket engine designs, and is being applied to the nozzle extension (NE) of the J-2X upper stage engine currently under development. Turbine exhaust gas (TEG) is injected tangentially from a manifold along the NE, and provides a thermal barrier from the core nozzle flow for the NE. As the TEG stream mixes with the nozzle flow, the effectiveness of the thermal barrier is reduced. This paper documents computational fluid dynamics (CFD) analysis work performed by NASA Marshall Space Flight Center (MSFC) to model the flow of the TEG through the manifold, into the nozzle, and the subsequent mixing of the TEG stream with the core flow. The geometry and grid of the TEG manifold, structural support ribs, and the NE wall will be shown, and the CFD boundary conditions described. The Loci-CHEM CFD code used in this work will also be briefly described. A unique approach to modeling the combined TEG manifold/thrust chamber assembly (TCA) was employed, as it was not practical to model the entire 360 circumferential range in one simulation. Prior CFD validation work modeling Calspan SSFC experiments in the early 1990s, documented in a previous AIAA paper, will also be briefly discussed. The fluid dynamics of the TEG flow through the manifold, into and between the structural support ribs, and into the nozzlette that feeds the TCA will be described. Significant swirl and non-uniformities are present, which along with the wakes from the ribs, act to degrade the film cooling effectiveness compared to idealized injection of TEG gas. The effect of these flow characteristics on the adiabatic wall temperature profile on the NE will be discussed.

Ruf, Joseph H.↗

SU-E-QI-06: Design and Initial Validation of a Precise Capillary Phantom to Test Perfusion Systems

Purpose: To design a precise perfusion phantom mimicking capillaries of the brain vasculature which could be used to test various perfusion protocols and algorithms which generate perfusion maps. Methods: A perfusion phantom was designed in Solidworks and built using additive manufacturing. The phantom was an overall cylindrical shape of diameter and height 20mm and containing capillaries of 200μm or 300μm which were parallel and in contact making up the inside volume where flow was allowed. We created a flow loop using a peristaltic pump and contrast agent was injected manually. Digital Subtraction Angiographic images and low contrast images with cone beam CT were acquired after the contrast was injected. These images were analyzed by our own code in LabVIEW software and Time-Density Curve, MTT and TTP was calculated. Results: Perfused area was visible in the cone beam CT images; however, individual capillaries were not distinguishable. The Time-Density Curve acquired was accurate, sensitive and repeatable. The parameters MTT, and TTP offered by the phantom were very sensitive to slight changes in the TDC shape. Conclusion: We have created a robust calibrating model for evaluation of existing perfusion data analysis systems. This approach is extremely sensitive to changes in the flow due to the high temporal resolution and could be used as a golden standard to assist developers in calibrating and testing of imaging perfusion systems and software algorithms. Supported by NIH Grant: 2R01EB002873 and an equipment grant from Toshiba Medical Systems Corporation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experimental investigation of a simulated LOX injector flow field

Current development of liquid oxidizer injectors for liquid rocket engines is highly dependent upon experimental investigations of the two-phase liquid oxidizer/gaseous fuel injection plume characteristics. This paper describes an effort to increase the applicability of optical diagnostic approaches to such flow fields find includes an innovative approach for interpreting laser-induced fluorescence signals from axisymmetric two-phase flows. The usefulness of both laser-induced fluorescence and surface scattering techniques are explored herein. The flow field selected for this investigation is an oxidizer-swirled, coaxial flow produced using an injector design under consideration for use in the Space Transportation Main Engine (STME). The liquid oxygen (LOX) flow through this injector is simulated using water. Photographs of laser-induced fluorescence and particle scattering and measured profiles of the mass distribution in this flow field are presented and discussed herein.

Hartfield, Roy J., Jr.↗

Three-Dimensional Pore Networks in Miocene Stevens Sandstone of California: Implications for CO 2 Geologic Storage

The Miocene Stevens Sandstone in the San Joaquin Basin of California is increasingly recognized as a promising candidate for CO 2 geological storage due to the enormous storage capacity, proven sealing, and existing infrastructure. In this study, computed microtomography imaging and pore network modeling were employed to investigate the influence of pore geometry and wettability on the CO 2 injectivity and residual trapping. Image analysis revealed that a significant fraction of the cement and matrix consists of microporous regions. The microporosity can substantially increase the overall pore space, yet its contribution to permeability remains modest, particularly in samples with low permeability. The intrinsic heterogeneity of turbidite reservoirs further complicates the reservoir properties among different layers. Two-phase flow simulations under varying wettability conditions (water-wet, weak water-wet, and neutral-wet) demonstrated that the CO 2 injection is predominantly controlled by macropores. CO 2 invades microporous regions only after these larger pores are filled. The presence of microporosity leads to a decrease in both initial and residual CO 2 saturations, with the magnitude of the reduction being influenced by wettability. Neutral-wet scenarios exhibit higher CO 2 mobility and thus lower residual trapping than water-wet scenarios. The results imply that heterogeneity in pore geometry and cement distribution across different layers can result in stratified CO 2 flow pathways, complicating efforts to predict injection performance. Overall, the Stevens Sandstone shows considerable promise for CO 2 geologic storage, but effective implementation will require detailed characterization of the pore structure as well as the integration of reactive fluid flow to account for potential mineral dissolution and fines migration.

fluids↗

Simulation of the impact of managed aquifer recharge on the groundwater system in Hanoi, Vietnam

A transient numerical groundwater flow model using MODFLOW-NWT was set up and calibrated for Hanoi city, Vietnam, to understand the local groundwater flow system and to suggest solutions for sustainable water resource management. Urban development in Hanoi has caused a severe decline of groundwater levels. The present study evaluates the actual situation and investigates the suitability of managed aquifer recharge (MAR) to stop further depletion of groundwater resources. The results suggest that groundwater is being overexploited, as vast cones of depression exist in parts of the study area. Suitable locations to implement two MAR techniques—riverbank filtration and injection wells—were identified using multi-criteria decision analysis based on geographic information system (GIS). Three predictive scenarios were simulated. The relocation of pumping wells towards the Red River to induce riverbank filtration (first scenario) demonstrates that groundwater levels can be increased, especially in the depression cones. Groundwater levels can also be improved locally by the infiltration of surplus water into the upper aquifer (Holocene) via injection wells during the rainy season (second scenario), but this is not effective to raise the water table in the depression cones. Compared to the first scenario, the combination of riverbank filtration and injection wells (third scenario) shows a slightly raised overall water table. Groundwater flow modeling suggests that local overexploitation can be stopped by a smart relocation of wells from the main depression cones and the expansion of riverbank filtration. This could also avoid further land subsidence while the city’s water demand is met.

58 GEOSCIENCES↗

Multi-Scale Mass Transfer Processes Controlling Natural Attenuation and Engineered Remediation: An IFRC Focused on Hanford’s 300 Area Uranium Plume January 2010 to January 2011

The Integrated Field Research Challenge (IFRC) at the Hanford Site 300 Area uranium (U) plume addresses multi-scale mass transfer processes in a complex subsurface hydrogeologic setting where groundwater and riverwater interact. A series of forefront science questions on reactive mass transfer focus research. These questions relate to the effect of spatial heterogeneities; the importance of scale; coupled interactions between biogeochemical, hydrologic, and mass transfer processes; and measurements and approaches needed to characterize and model a mass-transfer dominated system. The project was initiated in February 2007, with CY 2007, CY 2008, and CY 2009 progress summarized in preceding reports. A project peer review was held in March 2010, and the IFRC project has responded to all suggestions and recommendations made in consequence by reviewers and SBR/DOE. These responses have included the development of “Modeling” and “Well-Field Mitigation” plans that are now posted on the Hanford IFRC web-site. The site has 35 instrumented wells, and an extensive monitoring system. It includes a deep borehole for microbiologic and biogeochemical research that sampled the entire thickness of the unconfined 300 A aquifer. Significant, impactful progress has been made in CY 2010 including the quantification of well-bore flows in the fully screened wells and the testing of means to mitigate them; the development of site geostatistical models of hydrologic and geochemical properties including the distribution of U; developing and parameterizing a reactive transport model of the smear zone that supplies contaminant U to the groundwater plume; performance of a second passive experiment of the spring water table rise and fall event with a associated multi-point tracer test; performance of downhole biogeochemical experiments where colonization substrates and discrete water and gas samplers were deployed to the lower aquifer zone; and modeling of past injection experiments for model parameterization, deconvolution of well-bore flow effects, system understanding, and publication. We continued efforts to assimilate geophysical logging and 3D ERT characterization data into our site wide geophysical model, and have now implemented a new strategy for this activity to bypass an approach that was found unworkable. An important focus of CY 2010 activities has been infrastructure modification to the IFRC site to eliminate vertical well bore flows in the fully screened wells. The mitigation procedure was carefully evaluated and is now being implementated. A new experimental campaign is planned for early spring 2011 that will utilize the modified well-field for a U reactive transport experiment in the upper aquifer zone. Preliminary geophysical monitoring experiments of rainwater recharge in the vadose zone have been initiated with promising results, and a controlled infiltration experiment to evaluate U mobilization from the vadose zone is now under planning for the September 2011. The increasingly comprehensive field experimental results, along with the field and laboratory characterization, are leading to a new conceptual model of U(VI) flow and transport in the IFRC footprint and the 300 Area in general, and insights on the microbiological community and associated biogeochemical processes.

300 Area↗

Analysis of mass transport in an atmospheric pressure remote plasma-enhanced chemical vapor deposition process

In remote microwave plasma enhanced chemical vapor deposition processes operated at atmospheric pressure, high deposition rates are associated with the localization of precursors on the treated surface. We show that mass transport can be advantageously ensured by convection for the heavier precursor, the lighter being driven by turbulent diffusion toward the surface. Transport by laminar diffusion is negligible. The use of high flow rates is mandatory to have a good mixing of species. The use of an injection nozzle with micrometer-sized hole enables us to define accurately the reaction area between the reactive species. The localization of the flow leads to high deposition rates by confining the reactive species over a small area, the deposition yield being therefore very high. Increasing the temperature modifies nonlinearly the deposition rates and the coating properties.

36 MATERIALS SCIENCE↗

Thermal Characteristics and Structure of Fully-Modulated, Turbulent Diffusion Flames in Microgravity

Turbulent jet diffusion flames are studied in microgravity and normal gravity under fully-modulated conditions for a range of injection times and a 50% duty cycle. Diluted ethylene was injected through a 2-mm nozzle at a Reynolds number of 5,000 into an open duct, with a slow oxidizer co-flow. Microgravity tests are conducted in NASA's 2.2 Second Drop Tower. Flames with short injection times and high duty cycle exhibit a marked increase in the ensemble-averaged flame length due to the removal of buoyancy. The cycle-averaged centerline temperature profile reveals higher temperatures in the microgravity flames, especially at the flame tip where the difference is about 200 K. In addition, the cycle-averaged measurements of flame radiation were about 30% to 60% greater in microgravity than in normal gravity.

Hermanson, J. C.↗

Analysis of film cooling in rocket nozzles

This report summarizes the findings on the NASA contract NAG8-212, Task No. 3. The overall project consists of three tasks, all of which have been successfully completed. In addition, some supporting supplemental work, not required by the contract, has been performed and is documented herein. Task 1 involved the modification of the wall functions in the code FDNS (Finite Difference Navier-Stokes) to use a Reynolds Analogy-based method. This task was completed in August, 1992. Task 2 involved the verification of the code against experimentally available data. The data chosen for comparison was from an experiment involving the injection of helium from a wall jet. Results obtained in completing this task also show the sensitivity of the FDNS code to unknown conditions at the injection slot. This task was completed in September, 1992. Task 3 required the computation of the flow of hot exhaust gases through the P&W 40K subscale nozzle. Computations were performed both with and without film coolant injection. This task was completed in July, 1993. The FDNS program tends to overpredict heat fluxes, but, with suitable modeling of backside cooling, may give reasonable wall temperature predictions. For film cooling in the P&W 40K calorimeter subscale nozzle, the average wall temperature is reduced from 1750R to about 1050R by the film cooling. The average wall heat flux is reduced by a factor of 3.

Woodbury, Keith A.↗

Self-Recirculating Casing Treatment Concept for Enhanced Compressor Performance

A state-of-the-art CFD code (APNASA) was employed in a computationally based investigation of the impact of casing bleed and injection on the stability and performance of a moderate speed fan rotor wherein the stalling mass flow is controlled by tip flow field breakdown. The investigation was guided by observed trends in endwall flow characteristics (e.g., increasing endwall aerodynamic blockage) as stall is approached and based on the hypothesis that application of bleed or injection can mitigate these trends. The "best" bleed and injection configurations were then combined to yield a self-recirculating casing treatment concept. The results of this investigation yielded: 1) identification of the fluid mechanisms which precipitate stall of tip critical blade rows, and 2) an approach to recirculated casing treatment which results in increased compressor stall range with minimal or no loss in efficiency. Subsequent application of this approach to a high speed transonic rotor successfully yielded significant improvements in stall range with no loss in compressor efficiency.

Hathaway, Michael D.↗

Fifty Years of Fluidic Injection for Jet Noise Reduction

The paper reviews 50 years of research investigating jet noise reduction through fluidic injection. Both aqueous and gaseous injection concepts for supersonic and subsonic jet exhausts are discussed. Aqueous injection reduces jet noise by reducing main jet temperature through evaporation and main jet velocity through momentum transfer between water droplets and the main jet. In the launch vehicle environment where large quantities of fluid do not have to be carried with the vehicle, water injection is very effective at reducing excess overpressures. For in-flight use, aqueous injection is problematic as most studies show that either large quantities of water or high injection pressures are required to achieve noise reduction. The most effective noise reduction injection systems require water pressures above 2000 kPa (290 psi) and water-to-mainjet mass flow rates above 10% to achieve overall sound pressure level reductions of roughly 6 dB in the peak jet noise direction. Injection at lower pressure (roughly 1034 kPa or 150 psi) has resulted in a 1.6 EPNdb reduction in effective perceived noise level. Gaseous injection reduces noise through jet plume modifications resulting from the introduction of streamwise vorticity in the main jet. In subsonic single-stream jets, air injection usually produces the largest overall sound pressure level reductions (roughly 2 dB) in the peak jet noise direction. In dual-stream jets, properly designed injection systems can reduce overall sound pressure levels and effective perceived noise levels but care must be taken to choose injector designs that limit sound pressure level increases at high frequencies. A reduction of 1.0 EPNdB has been achieved with injection into the fan and core streams. However, air injection into dual-stream subsonic jets has received little attention and the potential for noise reduction is uncertain at this time. For dual-stream supersonic jets, additional research needs to be conducted to determine if reductions can be achieved with injection pressures available from current aircraft engines. 1.

Henderson, Brenda↗

Bubble Formation from Wall Orifice in Liquid Cross-Flow Under Low Gravity

Two-phase flows present a wide variety of applications for spacecraft thermal control systems design. Bubble formation and detachment is an integral part of the two phase flow science. The objective of the present work is to experimentally investigate the effects of liquid cross-flow velocity, gas flow rate, and orifice diameter on bubble formation in a wall-bubble injection configuration. Data were taken mainly under reduced gravity conditions but some data were taken in normal gravity for comparison. The reduced gravity experiment was conducted aboard the NASA DC-9 Reduced Gravity Aircraft. The results show that the process of bubble formation and detachment depends on gravity, the orifice diameter, the gas flow rate, and the liquid cross-flow velocity. The data are analyzed based on a force balance, and two different detachment mechanisms are identified. When the gas momentum is large, the bubble detaches from the injection orifice as the gas momentum overcomes the attaching effects of liquid drag and inertia. The surface tension force is much reduced because a large part of the bubble pinning edge at the orifice is lost as the bubble axis is tilted by the liquid flow. When the gas momentum is small, the force balance in the liquid flow direction is important, and the bubble detaches when the bubble axis inclination exceeds a certain angle.

Nahra, Henry K.↗

Farfield structure of an aircraft trailing vortex, including effects of mass injection

Wind tunnel tests to predict the aircraft wake turbulence due to the tip trailing vortex are discussed. A yawhead pressure probe was used in a subsonic wind tunnel to obtain detailed mean flow measurements at stations up to 30 chordlengths downstream in an aircraft trailing vortex. Mass injection at the wingtip was shown to hasten the decay of the trailing vortex. A theoretical method is presented to show the effect which the circulation distribution on the wing has on the structure of the outer portion of the vortex.

Mason, W. H.↗