Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fields”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Influence of high magnetic field on access to stationary H-modes and pedestal characteristics in Alcator C-Mod

We report recent Alcator C-Mod experiments have explored access to and characteristics of H-modes at magnetic fields approaching 8 T, the highest field achieved to date in a diverted tokamak. The H-modes originated from L-mode densities ranging from 1.1 x 10 20 m -3 to 2.8 x 10 20 m -3 , allowing insight into the density dependence of the H-mode power threshold at high magnetic field. This dependence is compared to predictions from the ITPA scaling law, finding that the law is approximately accurate at 7.8 T. However, the law underpredicted the high density H-mode threshold at lower magnetic field in previous C-Mod experiments, suggesting that the overall dependence of the threshold on magnetic field is weaker than predicted by the scaling law. The threshold data at 7.8 T also indicates that the onset of a low density branch at this magnetic field on C-Mod occurs below 1.4 x 10 20 m -3 , which is lower than predicted by an existing model for low density branch onset. The H-modes achieved steady-state densities ranging from 2.3 x 10 20 m -3 to 4.4 x 10 20 m -3 , and higher transient densities, and had values of q 95 from 3.3 to 6.0. This parameter range allowed the achievement of all three types of H-mode routinely observed at lower magnetic field on C-Mod: the stationary, ELM-suppressed Enhanced D α (EDA) regime, seen at high densities and high values of q 95 ; the nonstationary ELM-free regime, seen at lower densities and values of q 95 ; and the ELMy regime, seen at low density, moderate q 95 , and specialized plasma shape. The parameter space in which these regimes occur at 7.8 T is consistent with lower magnetic field experience. Pressure pedestal height at 7.8 T is compared to EPED predictions, and a scaling law for EDA density pedestal height developed between 4.5 T and 6.0 T is updated to include fields from 2.7 T to 7.8 T. Overall, this analysis increases confidence in the use of low magnetic field experience to predict some elements of high magnetic field tokamak behavior.

7.8 T↗

Deep-field analytical calibration

The next generation of imaging surveys, including the Vera C. Rubin Observatory Legacy Survey of Space and Time (LSST), Euclid, and the Nancy Grace Roman Space Telescope, will provide unprecedented constraints on cosmology using weak gravitational lensing. To fully exploit this statistical power, shear measurement methods must achieve sub- per cent accuracy while mitigating systematic biases from noise, the point-spread function (PSF), blending, and shear-dependent detection. The analytical calibration framework (AnaCal) has demonstrated such accuracy but requires adding noise to images, reducing effective depth. We introduce Deep-Field Analytical Calibration (DEEP-FIELD AnaCal), an extension of AnaCal that uses deep-field images to compute shear responses while preserving the statistical power of wide-field data. We validate DEEP-FIELD AnaCal on isolated and blended galaxy image simulations with LSST-like conditions, finding it meets the stringent requirement of multiplicative bias $|m| < 3\times 10^{-3}$ at 99.7 per cent confidence. Compared to standard AnaCal applied to wide-field images, DEEP-FIELD AnaCal increases the effective galaxy number density from 17 to 30 arcmin$^{-2}$ for simulated 10-yr LSST data. With deep fields $10\times$ longer than the wide field, we find pixel noise variance in shear estimation is reduced by 30 per cent and overall uncertainty by $\sim 25~{{\ \rm per\ cent}}$. Finally, using the LSST Deep Drilling Fields strategy, we assess sample variance and find an equivalent calibration uncertainty of $\lesssim 0.3~{{\ \rm per\ cent}}$. These results demonstrate that DEEP-FIELD AnaCal offers a promising path to achieve the required shear calibration for upcoming weak lensing surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Electric Field Analysis in a Cold-Ion Source Using Stark Spectroscopy of Rydberg Atoms

Here, we analyze electric fields in ion sources generated by quasicontinuous photoionization of cold Rb atoms trapped in the focal spot of a near-concentric, in-vacuum cavity for 1064-nm laser light. Ion streams are extracted with an external electric field, F. Stark effects of Rb 57F and of nearby high-angular-momentum Rydberg levels, which exhibit large, linear Stark shifts, are employed to study the net electric-field probability distribution within the ion-source region over an extraction-field range of 0 < F < 0.35 V/cm. For F = 0, we also investigate ion-field-induced Stark spectra of the 60P 1/2 state, which exhibits a (lesser) quadratic electric-field response that affords a simplified electric-field analysis. Experimental Rydberg spectra are compared with theoretical Stark spectra, which are weighted with net electric-field distributions obtained from classical ion-trajectory simulations that include Coulomb interactions. Experiments and models are in good agreement. At small F and high ion-source rates, the field approximately follows a Holtsmark distribution, and the ion streams are degraded by the Coulomb microfields. With increasing F and at lower ion-source rates, the fields become narrowly distributed around F, resulting in directional ion streams that are less degraded by microfields. Our results are of interest for monitoring cold-ion sources for focused-ion-beam applications, where Coulomb interactions are of concern, and for studies of electric fields in cold plasmas.

74 ATOMIC AND MOLECULAR PHYSICS↗

Lagrangian displacement field estimators in cosmology

The late-time nonlinear Lagrangian displacement field is highly correlated with the initial field, so reconstructing it could enable us to extract primordial cosmological information. Our previous work carefully studied the displacement field reconstructed from the late-time density field using the iterative method proposed and found that it does not fully converge to the true, underlying displacement field (e.g., ~8 % offset at k ~ 0.2 h Mpc –1 at z = 0.6 ). We also constructed the Lagrangian perturbation theory model for the reconstructed field, but the model could not explain the discrepancy between the true and the reconstructed fields in the previous work. Here, the main sources of the discrepancy were speculated to be a numerical artifact in the displacement estimator due to the discreteness of the sample. In this paper, we develop two new estimators of the displacement fields to reduce such a numerical discreteness effect, the normalized momentum estimator and the rescaled resumed estimator. We show that the discrepancy reported is not due to the numerical artifacts. We conclude that the method cannot fully reconstruct the shape of the nonlinear displacement field at the redshift we studied, while it is still an efficient baryon acoustic oscillation reconstruction method. In parallel, by properly accounting for the UV-sensitive term in a reconstruction procedure with an effective field theory approach, we improve the theoretical model for the reconstructed displacement field, by almost 5 times, from ~15% to the level of a few percent at k ~ 0.2 h Mpc –1 at the redshift z = 0.6.

79 ASTRONOMY AND ASTROPHYSICS↗

Biological effect of dose distortion by fiducial markers in spot-scanning proton therapy with a limited number of fields: A simulation study

Purpose: In accurate proton spot-scanning therapy, continuous target tracking by fluoroscopic x ray during irradiation is beneficial not only for respiratory moving tumors of lung and liver but also for relatively stationary tumors of prostate. Implanted gold markers have been used with great effect for positioning the target volume by a fluoroscopy, especially for the cases of liver and prostate with the targets surrounded by water-equivalent tissues. However, recent studies have revealed that gold markers can cause a significant underdose in proton therapy. This paper focuses on prostate cancer and explores the possibility that multiple-field irradiation improves the underdose effect by markers on tumor-control probability (TCP). Methods: A Monte Carlo simulation was performed to evaluate the dose distortion effect. A spherical gold marker was placed at several characteristic points in a water phantom. The markers were with two different diameters of 2 and 1.5 mm, both visible on fluoroscopy. Three beam arrangements of single-field uniform dose (SFUD) were examined: one lateral field, two opposite lateral fields, and three fields (two opposite lateral fields + anterior field). The relative biological effectiveness (RBE) was set to 1.1 and a dose of 74 Gy (RBE) was delivered to the target of a typical prostate size in 37 fractions. The ratios of TCP to that without the marker (TCP{sub r}) were compared with the parameters of the marker sizes, number of fields, and marker positions. To take into account the dependence of biological parameters in TCP model, {alpha}/{beta} values of 1.5, 3, and 10 Gy (RBE) were considered. Results: It was found that the marker of 1.5 mm diameter does not affect the TCPs with all {alpha}/{beta} values when two or more fields are used. On the other hand, if the marker diameter is 2 mm, more than two irradiation fields are required to suppress the decrease in TCP from TCP{sub r} by less than 3%. This is especially true when multiple (two or three) markers are used for alignment of a patient. Conclusions: It is recommended that 1.5-mm markers be used to avoid the reduction of TCP as well as to spare the surrounding critical organs, as long as the markers are visible on x-ray fluoroscopy. When 2-mm markers are implanted, more than two fields should be used and the markers should not be placed close to the distal edge of any of the beams.

60 APPLIED LIFE SCIENCES↗

Response of TLD-100 in mixed fields of photons and electrons

Purpose: Thermoluminescent dosimeters (TLDs) are routinely used for dosimetric measurements of high energy photon and electron fields. However, TLD response in combined fields of photon and electron beam qualities has not been characterized. This work investigates the response of TLD-100 (LiF:Mg,Ti) to sequential irradiation by high-energy photon and electron beam qualities. Methods: TLDs were irradiated to a known dose by a linear accelerator with a 6 MV photon beam, a 6 MeV electron beam, and a NIST-traceable {sup 60}Co beam. TLDs were also irradiated in a mixed field of the 6 MeV electron beam and the 6 MV photon beam. The average TLD response per unit dose of the TLDs for each linac beam quality was normalized to the average response per unit dose of the TLDs irradiated by the {sup 60}Co beam. Irradiations were performed in water and in a Virtual Water Trade-Mark-Sign phantom. The 6 MV photon beam and 6 MeV electron beam were used to create dose calibration curves relating TLD response to absorbed dose to water, which were applied to the TLDs irradiated in the mixed field. Results: TLD relative response per unit dose in the mixed field was less sensitive than the relative response in the photon field and more sensitive than the relative response in the electron field. Application of the photon dose calibration curve to the TLDs irradiated in a mixed field resulted in an underestimation of the delivered dose, while application of the electron dose calibration curve resulted in an overestimation of the dose. Conclusions: The relative response of TLD-100 in mixed fields fell between the relative response in the photon-only and electron-only fields. TLD-100 dosimetry of mixed fields must account for this intermediate response to minimize the estimation errors associated with calibration factors obtained from a single beam quality.

60 APPLIED LIFE SCIENCES↗

SU-E-T-17: A Mathematical Model for PinPoint Chamber Correction in Measuring Small Fields

Purpose: For small field dosimetry, such as measuring the cone output factor for stereotactic radiosurgery, ion chambers often result in underestimation of the dose, due to both the volume averaging effect and the lack of electron equilibrium. The purpose of this work is to develop a mathematical model, specifically for the pinpoint chamber, to calculate the correction factors corresponding to different type of small fields, including single cone-based circular field and non-standard composite fields. Methods: A PTW 0.015cc PinPoint chamber was used in the study. Its response in a certain field was modeled as the total contribution of many small beamlets, each with different response factor depending on the relative strength, radial distance to the chamber axis, and the beam angle. To get these factors, 12 cone-shaped circular fields (5mm,7.5mm, 10mm, 12.5mm, 15mm, 20mm, 25mm, 30mm, 35mm, 40mm, 50mm, 60mm) were irradiated and measured with the PinPoint chamber. For each field size, hundreds of readings were recorded for every 2mm chamber shift in the horizontal plane. These readings were then compared with the theoretical doses as obtained with Monte Carlo calculation. A penalized-least-square optimization algorithm was developed to find out the beamlet response factors. After the parameter fitting, the established mathematical model was validated with the same MC code for other non-circular fields. Results: The optimization algorithm used for parameter fitting was stable and the resulted response factors were smooth in spatial domain. After correction with the mathematical model, the chamber reading matched with the Monte Carlo calculation for all the tested fields to within 2%. Conclusion: A novel mathematical model has been developed for the PinPoint chamber for dosimetric measurement of small fields. The current model is applicable only when the beam axis is perpendicular to the chamber axis. It can be applied to non-standard composite fields. Further validation with other type of detectors is being conducted.

60 APPLIED LIFE SCIENCES↗

SU-E-T-262: Planning for Proton Pencil Beam Scanning (PBS): Applications of Gradient Optimization for Field Matching

Purpose: To propose the gradient optimization(GO) approach in planning for matching proton PBS fields and present two commonly used applications in our institution. Methods: GO is employed for PBS field matching in the scenarios that when the size of the target is beyond the field size limit of the beam delivery system or matching is required for beams from different angles to either improve the sparing of important organs or to pass through a short and simple beam path. Overlap is designed between adjacent fields and in the overlapped junction, the dose was optimized such that it gradually decreases in one field and the decrease is compensated by increase from another field. Clinical applications of this approach on craniospinal irradiation(CSI) and whole pelvis treatment were presented. Mathematical model was developed to study the relationships between dose errors, setup errors and junction lengths. Results: Uniform and conformal dose coverage to the entire target volumes was achieved for both applications using GO approach. For CSI, the gradient matching (6.7cm junction) between fields overcame the complexity of planning associated with feathering match lines. A slow dose gradient in the junction area significantly reduced the sensitivity of the treatment to setup errors. For whole pelvis, gradient matching (4cm junction) between posterior fields for superior target and bilateral fields for inferior target provided dose sparing to organs such as bowel, bladder and rectum. For a setup error of 3 mm in longitudinal direction from one field, mathematical model predicted dose errors of 10%, 6% and 4.3% for junction length of 3, 5 and 7cm. Conclusion: This GO approach improves the quality of the PBS treatment plan with matching fields while maintaining the safety of treatment delivery relative to potential misalignments.

60 APPLIED LIFE SCIENCES↗

SU-E-T-431: Vertically-Oriented Farmer-Type Chamber for Small-Field Applications

Purpose: To introduce a non-conventional measurement setup using Farmer-type chambers to accommodate several situations of small-field dose measurements without compromising accuracy. The validation of this technique was demonstrated for photon small-field output measurements, and electron small-field percentage depth-dose (PDD) measurements. Methods: Initial chamber alignment was performed using the conventional (horizontally-oriented) chamber setup. A PDD was acquired for a 4×4 cm{sup 2} field size using this arrangement. This PDD was used as a positional reference for the vertically-oriented chamber (VOC) configuration. Next, a PDD was acquired for a 4×4 cm{sup 2} field size with the VOC. The PDD's were superimposed to find the effective shift of the VOC. Using the shifted VOC setup, photon small-field output factors were measured and compared to stereotactic diode output factor measurements. Additionally, electron smallfield PDD's were acquired using the VOC setup and results were compared to electron Monte Carlo (eMC) predictions in the Eclipse treatment planning system (TPS). Results: (1) For photon small-field output factors field-sizes 2×2 cm{sup 2} and larger, the difference between the VOC setup and SFD measurements were less than 0.8%. For field sizes less than 2×2 cm{sup 2} discrepancies ranged from 4.0 to 10.6%. (2) PDD's measured by VOC setup show better than 1.6% agreement as compared to eMC for all electron energies measured down to the 80% depth on the 2×2 cm{sup 2} PDD curve. Disagreement between the VOC setup measurement and eMC calculations for depths down to the 50% depth on the PDD curve is 3.6% or less. Conclusion: Using the VOC setup, it is possible to use a conventional farmer chamber for small field-size measurements down to 2×2 cm{sup 2} field size without sacrificing the accuracy of measurements.

60 APPLIED LIFE SCIENCES↗

WE-G-17A-08: Electron Gun Operation for in Line MRI-Linac Configurations: An Assessment of Beam Fidelity and Recovery Techniques for Different SIDs and Magnetic Field Strengths

Purpose: To test the functionality of medical electron guns within the fringe field of a purpose built superconducting MRI magnet, and to test different recovery techniques for a variety of imaging field strengths and SIDs. Methods: Three different electron guns were simulated using Finite Element Modelling; a standard diode gun, a standard triode gun, and a novel diode gun designed to operate within parallel magnetic fields. The approximate working regime of each gun was established by assessing exit current in constant magnetic fields of varying strength and defining ‘working’ as less than 10% change in injection current. Next, the 1.0T MRI magnet was simulated within Comsol Multiphysics. The coil currents in this model were also scaled to produce field strengths of .5, 1, 1.5 and 3T. Various magnetic shield configurations were simulated, varying the SID from 800 to 1300mm. The average magnetic field within the gun region was assessed together with the distortion in the imaging volume - greater than 150uT distortion was considered unacceptable. Results: The conventional guns functioned in fields of less than 7.5mT. Conversely, the redesigned diode required fields greater than .1T to function correctly. Magnetic shielding was feasible for SIDS of greater than 1000mm for field strengths of .5T and 1T, and 1100mm for 1.5 and 3.0T. Beyond these limits shielding resulted in unacceptable MRI distortion. In contrast, the redesigned diode could perform acceptably for SIDs of less than 812, 896, 931, and 974mm for imaging strengths of 0.5, 1.0, 1.5, 3.0T. Conclusions: For in-line MRIlinac configurations where the electron gun is operating in low field regions, shielding is a straight forward option. However, as magnetic field strength increases and the SID is reduced, shielding results in too great a distortion in the MRI and redesigning the electron optics is the preferable solution. The authors would like to acknowledge funding from the National Health and Research Council (AUS), National Institute of Health (NIH), and Cancer Institute NSW.

43 PARTICLE ACCELERATORS↗

Effects of spin-lock field direction on the quantitative measurement of spin-lattice relaxation time constant in the rotating frame (T1ρ) in a clinical MRI system

Purpose: To investigate whether the direction of spin-lock field, either parallel or antiparallel to the rotating magnetization, has any effect on the spin-lock MRI signal and further on the quantitative measurement of T1ρ, in a clinical 3 T MRI system. Methods: The effects of inverted spin-lock field direction were investigated by acquiring a series of spin-lock MRI signals for an American College of Radiology MRI phantom, while the spin-lock field direction was switched between the parallel and antiparallel directions. The acquisition was performed for different spin-locking methods (i.e., for the single- and dual-field spin-locking methods) and for different levels of clinically feasible spin-lock field strength, ranging from 100 to 500 Hz, while the spin-lock duration was varied in the range from 0 to 100 ms. Results: When the spin-lock field was inverted into the antiparallel direction, the rate of MRI signal decay was altered and the T1ρ value, when compared to the value for the parallel field, was clearly different. Different degrees of such direction-dependency were observed for different spin-lock field strengths. In addition, the dependency was much smaller when the parallel and the antiparallel fields are mixed together in the dual-field method. Conclusions: The spin-lock field direction could impact the MRI signal and further the T1ρ measurement in a clinical MRI system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-D-304-03: Small Field Proton Dosimetry Using MicroDiamond and Gafchromic Film

Purpose: Certain dosimetric characteristics continue to make proton beam therapy an appealing modality for cancer treatment. The proton Bragg peak allows for conformal radiation dose delivery to the target while reducing dose to normal tissue and organs. As field sizes become very small the benefit of the Bragg peak is diminished due to loss of transverse equilibrium along the central beam axis. Furthermore, aperture scattering contributes additional dose along the central axis. These factors warrant the need for accurate small field dosimetry. In this study small field dosimetry was performed using two different methods. Methods: Small field dosimetry measurements were performed using a PTW microdiamond detector and Gafchromic EBT2 film for aperture sizes ranging from 0.5cm to 10cm and a proton range in water of 10cm to 27cm. The measurements were analyzed and then compared to each other and to reference dosimetry data acquired with a Markus chamber. Results: A decrease in normalized output is observed at small field sizes and at larger ranges in water using both measurement methods. Also, a large variation is observed between the output measurements by microdiamond and film at very small field sizes. At the smallest aperture, normalized output ranged from 0.16 to 0.72 and the percent difference between both measurement methods ranged from 36% to 70% depending on proton range. At field sizes above 5cm the film and microdiamond agree within 3%. Conclusion: Although both measurement methods exhibit a general decrease in output factor at small field sizes, dosimetric measurements for small fields using these two methods can vary significantly. Dosimetry under standard conditions is not sufficient to correctly model the dose distributions and outputs factors for small field sizes, additional small field measurements should be performed.

60 APPLIED LIFE SCIENCES↗

SU-E-T-134: Assessing the Capabilities of An MU Model for Fields as Small as 2cm in a Passively Scattered Proton Beam

Purpose: To assess and expand the capabilities of the current MU model for a passively scattered proton beam. The expanded MU model can potentially be used to predict the dose/MU for fields smaller than 2cm in diameter and reduce time needed for physical calibrations. Methods: The current MU model accurately predicted the dose/MU for more than 800 fields when compared to physical patient calibrations. Three different ion chambers were used in a Plastic Water phantom for physical measurements: T1, PIN, and A-16. The original MU model predicted output for fields that were affected by the bolus gap factor (BGF) and nozzle extension factor (NEF). As the system was tested for smaller treatment fields, the mod wheel dependent field size factor (MWDFSF) had to be included to describe the changes observed in treatment fields smaller than 3cm. The expanded model used Clarkson integration to determine the appropriate value for each factor (field size factor (FSF), BGF, NEF, and MWDFSF), to accurately predict the dose/MU for fields smaller than 2.5cm in effective diameter. Results: The expanded MU model demonstrated agreement better than 2% for more than 800 physical calibrations that were tested. The minimum tested fields were 1.7cm effective diameter for 149MeV and 2.4cm effective diameter for 186MeV. The inclusion of Clarkson integration into the MU model enabled accurate prediction of the dose/MU for very small and irregularly shaped treatment fields. Conclusion: The MU model accurately predicted the dose/MU for a wide range of treatment fields used in the clinic. The original MU model has been refined using factors that were problematic to accurately predict the dose/MU: the BGF, NEF, and MWDFSF. The MU model has minimized the time for determining dose/MU and reduced the time needed for physical calibrations, improving the efficiency of the patient treatment process.

60 APPLIED LIFE SCIENCES↗

SU-F-T-610: Comparison of Output Factors for Small Radiation Fields Used in SBRT Treatment

Purpose: In order to fundamentally understand our previous dose verification results between measurements and calculations from treatment planning system (TPS) for SBRT plans for different sized targets, the goal of the present work was to compare output factors for small fields measured using EDR2 films with TPS and Monet Carlo (MC) simulations. Methods: 6MV beam was delivered to EDR2 films for each of the following field sizes; 1×1 cm{sup 2}, 1.5×1.5 cm{sup 2}, 2×2 cm{sup 2}, 3×3 cm{sup 2}, 4×4 cm{sup 2}, 5×5 cm{sup 2} and 10×10 cm{sup 2}. The films were developed in a film processer, then scanned with a Vidar VXR-16 scanner and analyzed using RIT113 version 6.1. A standard calibration curve was obtained with the 6MV beam and was used to get absolute dose for measured field sizes. Similar plans for all fields sizes mentioned above were generated using Eclipse with the Analytical Anisotropic Algorithm. Similarly, MC simulations were carried out using the MCSIM, an in-house MC code for different field sizes. Output factors normalized to 10×10 cm{sup 2} reference field were calculated for different field sizes in all the three cases and compared. Results: For field sizes ranging from 1×1 cm{sup 2} to 2×2 cm{sup 2}, the differences in output factors between measurements (films), TPS and MC simulations were within 0.22%. For field sizes ranging from 3×3cm{sup 2} to 5×5cm{sup 2}, differences in output factors were within 0.10%. Conclusion: No clinically significant difference was obtained in output factors for different field sizes acquired from films, TPS and MC simulations. Our results showed that the output factors are predicted accurately from TPS when compared to the actual measurements and superior dose calculation Monte Carlo method. This study would help us in understanding our previously obtained dose verification results for small fields used in the SBRT treatment.

60 APPLIED LIFE SCIENCES↗

SU-G-BRB-12: Polarity Effects in Small Volume Ionization Chambers in Small Fields

Purpose: Dosimetric quantities such as the polarity correction factor (Ppol) are important parameters for determining the absorbed dose and can influence the choice of dosimeter. Ppol has been shown to depend on beam energy, chamber design, and field size. This study is to investigate the field size and detector orientation dependence of Ppol in small fields for several commercially available micro-chambers. Methods: We evaluate the Exradin A26, Exradin A16, PTW 31014, PTW 31016, and two prototype IBA CC-01 micro-chambers in both horizontal and vertical orientations. Measurements were taken at 10cm depth and 100cm SSD in a Wellhofer BluePhantom2. Measurements were made at square fields of 0.6, 0.8, 1.0, 1.2, 1.4, 2.0, 2.4, 3.0, and 5.0 cm on each side using 6MV with both ± 300VDC biases. PPol was evaluated as described in TG-51, reported using −300VDC bias for Mraw. Ratios of PPol measured in the clinical field to the reference field are presented. Results: A field size dependence of Ppol was observed for all chambers, with increased variations when mounted vertically. The maximum variation observed in PPol over all chambers mounted horizontally was <1%, and occurred at different field sizes for different chambers. Vertically mounted chambers demonstrated variations as large as 3.2%, always at the smallest field sizes. Conclusion: Large variations in Ppol were observed for vertically mounted chambers compared to horizontal mountings. Horizontal mountings demonstrated a complicated relationship between polarity variation and field size, probably relating to differing details in each chambers construction. Vertically mounted chambers consistently demonstrated the largest PPol variations for the smallest field sizes. Measurements obtained with a horizontal mounting appear to not need significant polarity corrections for relative measurements, while those obtained using a vertical mounting should be corrected for variations in PPol.

07 ISOTOPE AND RADIATION SOURCES↗

Strain-switchable field-induced superconductivity

Field-induced superconductivity is a rare phenomenon where an applied magnetic field enhances or induces superconductivity. Here, we use applied stress as a control switch between a field-tunable superconducting state and a robust non–field-tunable state. This marks the first demonstration of a strain-tunable superconducting spin valve with infinite magnetoresistance. We combine tunable uniaxial stress and applied magnetic field on the ferromagnetic superconductor Eu(Fe 0.88 Co 0.12 ) 2 As 2 to shift the field-induced zero-resistance temperature between 4 K and a record-high value of 10 K. We use x-ray diffraction and spectroscopy measurements under stress and field to reveal that strain tuning of the nematic order and field tuning of the ferromagnetism act as independent control parameters of the superconductivity. Combining comprehensive measurements with DFT calculations, we propose that field-induced superconductivity arises from a novel mechanism, namely, the uniquely dominant effect of the Eu dipolar field when the exchange field splitting is nearly zero.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

NUMERICAL CALCULATION OF LOSSES OF TRAPPED VORTICES UNDER STRONG RF MEISSNER CURRENT AND DC SUPERHEATING FIELD IN TYPE II SUPERCONDUCTORS

Research on the vortex dynamics and enhancing of superheating field in superconductors has attracted much attention in accelerator physics community to develop next-generation high-performance accelerator cavities. However, the extreme dynamics of curvilinear elastic vortices driven by very strong currents close to the depairing limit or superheating field of a superconductor with a nanostructured surface has not been well understood. We calculated the superheating field Hsh and critical momentum kc characterizing the wavelength of the instability ?m of the Meissner state to flux penetration by solving numerically the Ginzburg?Landau equations. A bulk superconductor, superconductor with the inhomogeneous surface disorder (S-S), and multilayered surface (S-I-S) have been thoroughly investigated in this work. Our result showed that S-S and S-I-S structures can enhance the superheating field well above their clean limit. In this work extensive numerical simulation of the power dissipated by an oscillating vortex segment driven by the surface ac Meissner currents was performed. Our simulations take into account the nonlinear vortex line tension, vortex mass, Bardeen?Stephen viscous vortex drag applicable at low fields, and nonlinear Larkin-Ovchinnikov (LO) viscous drag coefficient ?(v) at high fields and pinning force. We showed that the LO decrease of ?(v) with the vortex velocity v could radically change the field dependence of the surface resistance Ri(H) caused by trapped vortices. At low frequencies Ri(H) exhibits a conventional increase with H. However, as frequency increases, the surface resistance becomes a nonmonotonic function of H which decreases with H at higher fields irrespective of the pinning distribution. Overheating can mask the descending field dependence of Ri(H) as frequency increases. Our numerical simulations also show that the LO effect can cause a vortex bending instability at high field amplitudes and frequencies, giving rise to the formation of dynamic kinks along with the vortex when a vortex is pinned strongly to one end. Nonlinear losses of trapped vortices in thick films under high-amplitude RF fields as functions of frequency, mean free path and pinning characteristics have been calculated.

Pathirana, Walive↗

Influence of High Magnetic Field on Access to Stationary H-modes and Pedestal Characteristics in Alcator C-Mod

Recent Alcator C-Mod experiments have explored access to and characteristics of H-modes at magnetic fields approaching 8 T, the highest field achieved to date in a diverted tokamak. The H-modes originated from L-mode densities ranging from $1.1 \times 10^{20} m^{-3}$ to $2.8 \times 10^{20} m^{-3}$, allowing insight into the density dependence of the H-mode power threshold at high magnetic field. This dependence is compared to predictions from the ITPA scaling law (\cite{martin2008power}), finding that the law is approximately accurate at 7.8 T. However, the law underpredicted the high density H-mode threshold at lower magnetic field in previous C-Mod experiments (\cite{ma2012scaling}), \hl{suggesting that the overall dependence of the threshold on magnetic field is weaker than predicted by the scaling law.} The threshold data at 7.8 T also indicates that the onset of a low density branch at this magnetic field on C-Mod occurs below $1.4 \times 10^{20} m^{-3}$, which is lower than predicted by an existing model for low density branch onset. The H-modes achieved steady-state densities ranging from $2.3 \times 10^{20} m^{-3}$ to $4.4 \times 10^{20} m^{-3}$, and higher transient densities, and had values of $q_{95}$ from 3.3 to 6.0. This parameter range allowed the achievement of all three types of H-mode routinely observed at lower magnetic field on C-Mod: the stationary, ELM-suppressed enhanced D-alpha (EDA) regime, seen at high densities and high values of $q_{95}$; the nonstationary ELM-free regime, seen at lower densities and values of $q_{95}$; and the ELMy regime, seen at low density, moderate $q_{95}$, and specialized plasma shape. The parameter space in which these regimes occur at 7.8 T is consistent with lower magnetic field experience. Pressure pedestal height at 7.8 T is compared to EPED \cite{snyder2009development, snyder2011first} predictions, and a scaling law for EDA density pedestal height developed between 4.5 and 6.0 T is updated to include fields from 2.7 T to 7.8 T. Overall, this analysis increases confidence in the use of low magnetic field experience to predict some elements of high magnetic field tokamak behavior.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗