Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distribution grid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Grid Strength Assessment for High Levels of Inverter-based Resources in the Puerto Rico Power

A system-wide assessment of the Puerto Rico power system grid strength is studied when considering high levels of inverter-based resource penetration. This study is carried out in PSSE and assesses the impact of inverter-based resource (IBR) contributions in response to three-phase ground faults. A hypothetical 100% inverter-based generation scenario is created to assess the extreme impact on short circuit levels and a realistic scenario is considered to assess the impact to short circuit ratios. The overall conclusion is that short circuit capacity and current will drastically decrease in a high IBR scenario, an effect that is quantified in this paper. The short circuit ratio metric is typically used to assess the impact of IBR but generally overestimates grid strength due to not accounting for the impact from multiple IBRs. Other methods such as equivalent circuit based short circuit ratio and weighted short circuit ratio offer a more comprehensive consideration for multiple IBRs and can better account for their mutual interactions. The work presented in this paper is part of the PR100 study.

inverter based resources, PR100, grid strength↗

Resilient Information Architecture Platform for Smart Grid (RIAPS)

A number of emerging trends will substantially alter the operation and control of the electric grid over the next several decades. These trends include ensuring resiliency under severe weather events, increasing integration of renewable electricity generation, supporting changing electricity demand patterns, and the improving cost effectiveness of distributed energy resources. To address these challenges, the future “Smart Grid” management will need to transition from centralized to coordinated distributed control paradigm. Reliable operation of the Smart Grid depends on distributed intelligence realized through software applications that run on distributed computing devices attached to the power system to collect data and collaboratively manage resources. However, much of the existing software for Smart Grid-enabled devices is either proprietary or developed with custom solutions, which limits interoperability among the heterogeneous devices and hinders the ability to manage system-level reliability, security, and resiliency requirements. Additionally, this approach makes Smart Grid applications hard to maintain, evolve, verify, and replace; resulting in high development and deployment costs. Further development of the Smart Grid requires a reusable software base-layer to move from hard-coded functionality to a plug-and-play architecture capable of managing system-level objectives and constraints in addition to providing consistent common services across heterogeneous devices and applications. Vanderbilt University, in collaboration with North Carolina State University and Washington State University has developed a foundation ‘software platform’ for developing and deploying robust, reliable, effective and secure software applications for the Smart Grid. The Resilient Information Architecture Platform for the Smart Grid (RIAPS) provides core services for building effective and powerful smart grid applications. It offers unique services for real-time data dissemination, fault tolerance, and coordination across apps distributed over the network.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Smart Meter Pinging and Reading Through AMI Two-Way Communication Networks to Monitor Grid Edge Devices and DERs

Today’s power distribution system is changing to a power-electronics-enabled distribution system, especially with the increasing penetration of distributed energy resources (DERs). To monitor and manage those electronic devices and DERs at the grid edge, the advanced metering infrastructure (AMI) with two-way communications presents great potential. At present, extensive research explores the upstream communication from smart meters to electric utilities (e.g., meter reading) but few examine the downstream communication from the utilities to smart meters (e.g., meter pinging). This article discusses the AMI two-way communication and its recent industrial practice in the U.S., especially for applying the smart meter pinging functionality to monitor grid-edge devices and DERs. This paper then develops the two-way communication model and the network calculus method to quantify the impact of the two-way communication on the AMI network. In the end, the proposed method is validated with ns-3 simulation using the modified 13-node test feeder and real-world feeder systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A simple way to integrate distributed storage into a wholesale electricity market

Abstract Current plans to decarbonize the electric supply system imply that the generation from wind and solar sources will grow substantially. This growth will increase the uncertainty of system operations due to the inherent variability of these renewable sources, and as a result, more reserve capacity will be required to provide the ramping (flexibility) needed for reliable operations. This paper assumes that all of the increased uncertainty comes from wind farms on the grid, and it shows how distributed storage managed locally by aggregators can provide the ramping needed without introducing a separate market for flexibility. This can be accomplished when the aggregators minimize the expected daily cost of the energy purchased from the grid for their customers by submitting optimal bids into the wholesale market with high and low price thresholds for discharging and charging the storage. This model is illustrated using a stochastic multi-period security constrained optimal power flow together with realistic data for a reduction of the network in the Northeast Power Coordinating Council region of the United States. The results show that the bidding strategy for distributed storage provides ramping to the grid just as effectively as storage managed by a system operator.

Lamadrid, Alberto J.↗

Model Quality and Measurement Density Impact on Volt/Volt Ampere Reactive Optimization Performance

The operation of the utility grid is being reshaped by the continuous addition of distributed energy resources and advanced metering infrastructure, which challenge existing grid control strategies. Some utilities deploy advanced distribution management systems (ADMS) to assist with the consolidation of various applications and to augment situational awareness in response to the new power delivery dynamics. An ADMS is an integrated software platform that provides utilities with a way to enhance their reliability, control, and optimization with advanced applications, such as volt/VAR optimization (VVO). A VVO application could serve as a vehicle to deliver cost savings by providing the utility with a method to reduce rates by controlling the voltage and decreasing the energy usage in their service territory. Some utilities are reluctant to integrate an ADMS, because it is a significant investment that requires approval from the public regulatory commission and/or their customers. This paper evaluates the impact on VVO performance when using a lower-quality network model supplemented with additional measurements, which could provide an implementation for cost savings. The results show that a better model quality would provide the highest energy savings; however, some level of telemetry is necessary in all scenarios to prevent voltage exceedances.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Final Technical Report for Contract No. DE-EE0006332, "Integrated Simulation Development and Decision Support Tool-Set for Utility Market and Distributed Solar Power Generation"

This project will enable utilities to develop long-term strategic plans that integrate high levels of renewable energy generation, and to better plan power system operations under high renewable penetration. The program developed forecast data streams for decision support and effective integration of centralized and distributed solar power generation in utility operations. This toolset focused on real time simulation of distributed power generation within utility grids with the emphasis on potential applications in day ahead (market) and real time (reliability) utility operations. The project team developed and demonstrated methodologies for quantifying the impact of distributed solar generation on core utility operations, identified protocols for internal data communication requirements, and worked with utility personnel to adapt the new distributed generation (DG) forecasts seamlessly within existing Load and Generation procedures through a sophisticated DMS. This project supported the objectives of the SunShot Initiative and SUNRISE by enabling core utility operations to enhance their simulation capability to analyze and prepare for the impacts of high penetrations of solar on the power grid. The impact of high penetration solar PV on utility operations is not only limited to control centers, but across many core operations. Benefits of an enhanced DMS using state-of-the-art solar forecast data were demonstrated within this project and have had an immediate direct operational cost savings for Energy Marketing for Day Ahead generation commitments, Real Time Operations, Load Forecasting (at an aggregate system level for Day Ahead), Demand Response, Long term Planning (asset management), Distribution Operations, and core ancillary services as required for balancing and reliability. This provided power system operators with the necessary tools and processes to operate the grid in a reliable manner under high renewable penetration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Valuation Framework for Informing Grid Modernization Decisions: Guidelines

Advances in technologies to provide electric power (e.g., renewable energy and battery storage), measurements and monitoring (e.g., synchrophasors, smart meters), communication (e.g., cellular service, Internet utilities), computing (powerful distributed microprocessors), and innovations in grid topologies and configurations (e.g., microgrids) have markedly changed the options available to provide electricity to end-users. The value propositions for electrical service have similarly become much more complex and diverse. The values of a grid design option can no longer be expressed by just using historical costemissions-reliability metrics. Nor can major decisions be made through closed analysis without consideration of the different stakeholders affected by a decision. This valuation framework provides a structure for valuation that is deliberate, inclusive, and transparent, documenting the intermediate and final results to ensure clarity, accountability and repeatability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Smart Contracts for Power Grid Applications Using the Advanced DLT Cyber Grid Guard Testbed

In this study is presented two power system applications with distributed ledger technology (DLT) and smart contracts (SC) that were assessed in a Cyber-Grid-Guard System (CGGS) advanced testbed, with protective relays, power meters, communication devices, DLT devices, synchronized time source, clock displays and real time simulator. This CGGS testbed was set in the Advanced Protection Lab, 252 lab space of the Grid Research Integration and Deployment Center (GRID- C), at Oak Ridge National Laboratory. In power grids, customer-owned distributed energy resources (DERs) are more frequent than in the past, and the numbers of points of interconnection (POI) with customer-owned DERs have increased. Disruptive operation from DERs presents a risk to grid operations, and protective relays located at the POI are used to isolate out-of-tolerance or poorly behaving of DERs. Ensuring the integrity of data from the relays at the POI, and DLT could enhance the security of the power grids. The first application is a SC to define and control the allowable total power factor (TPF) of the DER (wind farm) output, and the terms of the SC are implemented using DLT with a CGGS for a customer-owned DER. The TPF SC was implemented by the CGGS using DLT. The experimental model was performed with a real-time simulator using a CGGS and relay in-the-loop. The data collected from the CGGS were used to execute the TPF SC. The TPF limits were between +0.9 and +1.0, and the breakers’ operation in the POI was controlled by the relay using the SC. The events were collected from the real-time simulator, CGGS, and SEL 700GT relay to validate a successful application of the TPF SC using DLT. The second application is a SC to measure and control the allowable voltage service limits (VSL) by the CGGS using DLT. The tests were performed by using a real-time simulator, CGGS and relay in-the-loop. The data was collected from the CGGS that executed the SC. The main constraints were defined based on ANSI C84.1 service voltage limits, and the operation of the breakers in the POI. The events were collected from the CGGS, and SEL 700GT relay to assess a successful operation of the VSL SC using DLT.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Poster: Responsible Adoption of Artificial Intelligence (AI) in Electric Grid Operations

The rapid integration of artificial intelligence (AI) in the utility transmission and distribution (T&D) sector is revolutionizing traditional grid management practices. As utilities encounter complexities from evolving consumer behaviors and energy integration, AI becomes a critical solution for enhancing grid monitoring, fault detection, and operational optimization. However, increased reliance on interconnected technologies introduces significant cybersecurity risks, regulatory compliance challenges, and human factors concerns. This study proposes a strategic, responsible and consequence-driven approach to AI implementation, examining the dual nature of AI adoption by highlighting its transformative benefits for utilities and associated risks. It provides utilities with a framework for evaluating AI integration, enabling them to navigate challenges and capitalize on opportunities to achieve greater reliability, efficiency, and resilience in an increasingly complex energy landscape.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Cybersecurity Considerations for Grid-Connected Batteries with Hardware Demonstrations

The share of renewable and distributed energy resources (DERs), like wind turbines, solar photovoltaics and grid-connected batteries, interconnected to the electric grid is rapidly increasing due to reduced costs, rising efficiency, and regulatory requirements aimed at incentivizing a lower-carbon electricity system. These distributed energy resources differ from traditional generation in many ways including the use of many smaller devices connected primarily (but not exclusively) to the distribution network, rather than few larger devices connected to the transmission network. DERs being installed today often include modern communication hardware like cellular modems and WiFi connectivity and, in addition, the inverters used to connect these resources to the grid are gaining increasingly complex capabilities, like providing voltage and frequency support or supporting microgrids. To perform these new functions safely, communications to the device and more complex controls are required. The distributed nature of DER devices combined with their network connectivity and complex controls interfaces present a larger potential attack surface for adversaries looking to create instability in power systems. To address this area of concern, the steps of a cyberattack on DERs have been studied, including the security of industrial protocols, the misuse of the DER interface, and the physical impacts. These different steps have not previously been tied together in practice and not specifically studied for grid-connected storage devices. In this work, we focus on grid-connected batteries. We explore the potential impacts of a cyberattack on a battery to power system stability, to the battery hardware, and on economics for various stakeholders. We then use real hardware to demonstrate end-to-end attack paths exist when security features are disabled or misconfigured. Our experimental focus is on control interface security and protocol security, with the initial assumption that an adversary has gained access to the network to which the device is connected. We provide real examples of the effectiveness of certain defenses. This work can be used to help utilities and other grid-connected battery owners and operators evaluate the severity of different threats and the effectiveness of defense strategies so they can effectively deploy and protect grid-connected storage devices.

25 ENERGY STORAGE↗

Advanced Photovoltaic Inverter Control Development and Validation in a Controller-Hardware-in-the-Loop Test Bed

Penetration of solar photovoltaic (PV) installations into the grid has increased in recent years. In the past, photovoltaic installations have not included grid-support functionality. Grid support functions including Volt-VAR (VVAR), Frequency-Watt (FW), Volt-Watt (VW), frequency/voltage-ride through, as well as other inverter functions such as anti-islanding are recommended by standards such as IEEE 1547 to allow PV inverters to contribute to acceptable operation and stability of distribution systems with high penetrations of PV and to ensure predictable response of the PV inverters. First, low-level and high-level grid support inverter control functions were developed and tested in simulation. The developed controller is able to integrate advanced controller functions in a coordinated approach, avoiding any conflict between the different control objectives. The algorithms were then programmed on an off-the-shelf embedded controller that included a dual-core CPU and FPGA. The details of the high-level grid support function and the lower level switching control will be presented. Second, this programmed controller is tested using a controller-hardware-in-the-loop (CHIL) test bed setup using an FPGA-based real-time simulator. The CHIL setup has the capability to run at a 500 nano-second time-step to accommodate the 20 kHz switching frequency of the developed controller. The advanced control function and CHIL test bed details provided here will aide future researchers to design, implement, and test advanced inverter functions for PV inverters.

14 SOLAR ENERGY↗

Mapping robust parallel multigrid algorithms to scalable memory architectures

The convergence rate of standard multigrid algorithms degenerates on problems with stretched grids or anisotropic operators. The usual cure for this is the use of line or plane relaxation. However, multigrid algorithms based on line and plane relaxation have limited and awkward parallelism and are quite difficult to map effectively to highly parallel architectures. Newer multigrid algorithms that overcome anisotropy through the use of multiple coarse grids rather than relaxation are better suited to massively parallel architectures because they require only simple point-relaxation smoothers. In this paper, we look at the parallel implementation of a V-cycle multiple semicoarsened grid (MSG) algorithm on distributed-memory architectures such as the Intel iPSC/860 and Paragon computers. The MSG algorithms provide two levels of parallelism: parallelism within the relaxation or interpolation on each grid and across the grids on each multigrid level. Both levels of parallelism must be exploited to map these algorithms effectively to parallel architectures. This paper describes a mapping of an MSG algorithm to distributed-memory architectures that demonstrates how both levels of parallelism can be exploited. The result is a robust and effective multigrid algorithm for distributed-memory machines.

Overman, Andrea↗

Study of ion flow dynamics in an inertial electrostatic confinement device through sequential grid construction

Experiments were performed to understand the dynamics of the ion flow in an inertial electrostatic confinement (IEC) device. This was done by monitoring the fusion rate as the symmetry of the grid was increased starting with a single loop all the way until the entire grid is constructed. The fusion rate was observed to increase with grid symmetry and eventually saturate. A single loop grid was observed to generate a cylindrical ({approx}line) fusion source. The ion flow distribution was measured by introducing fine wires across a single loop of the grid in the form of a chord of a circle (chord wires). This study revealed that with increased symmetry of the cathode grid wires the convergence of the ions improves. The chord wires provided electrons for ionization even at low pressures ({approx}6.67 mPa) and helped sustain the plasma. The impinging ions heat these wires locally and the temperature of the wires was measured using an infrared thermometer that was used to understand the ion flow distribution across the cathode grid. The presence of the grid wires seems to affect the fusion rate more drastically than previously thought (was assumed to be uniform around the central grid). Most of the fusion reactions were observed to occur in the ion microchannels that form in gaps between the cathode wires. This work helps understand the fusion source regimes and calibrate the IEC device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Method and system for providing flexible reserve power for power grid

An optimization-based method and system is disclosed to enable heterogeneous loads and distributed energy resources (DERs) to participate in grid ancillary services, such as spinning and non-spinning reserves, and ramping reserves. The method includes receiving inputs for decision parameters for optimizing an objective for obtaining flexible reserve power, solving the objective for obtaining flexible reserve power, determining a reserve power schedule for a prediction horizon for providing flexible reserve power based on the objective, generating a service bid based on the reserve power schedule for the power grid; and when the service bid is accepted, providing flexible reserve power to the power grid based on the service bid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

2015 California Demand Response Potential Study - Charting California’s Demand Response Future. Interim Report on Phase 1 Results

Demand response (DR) is an important resource for keeping the electricity grid stable and efficient; deferring upgrades to generation, transmission, and distribution systems; and providing other customer economic benefits. This study estimates the potential size and cost of the available DR resource for California’s three investor-owned utilities (IOUs), as the California Public Utilities Commission (CPUC) evaluates how to enhance the role of DR in meeting California’s resource planning needs and operational requirements. As the state forges a clean energy future, the contributions of wind and solar electricity from centralized and distributed generation will fundamentally change the power grid’s operational dynamics. This transition requires careful planning to ensure sufficient capacity is available with the right characteristics – flexibility and fast response – to meet reliability needs. Illustrated is a snapshot of how net load (the difference between demand and intermittent renewables) is expected to shift. Increasing contributions from renewable generation introduces steeper ramps and a shift, into the evening, of the hours that drive capacity needs. These hours of peak capacity need are indicated by the black dots on the plots. Ultimately this study quantifies the ability and the cost of using DR resources to help meet the capacity need at these forecasted critical hours in the state.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Maximizing Earth Science Observations with Data Harmonization: Harmonized Landsat/Sentinel-2

In August 2021, NASA released science quality harmonized Landsat/Sentinel-2 products for both cloud-based access and direct download from the Land Processes Distributed Active Archive Center (LP DAAC). These 30-meter products, HLSS30 (Sentinel-2 component) and HLSL30 (Landsat component) are placed on the same grid and are generated and distributed fully in the cloud. Similarly, ESA is prototyping harmonized Landsat Sentinel-2 products at 10-meter resolution. The data production and science teams from NASA and ESA will present technical details on the data production system, data product status and availability, and the benefit of harmonizing instruments with similar sensing characteristics between the agencies.

Earth Science↗

Mapping robust parallel multigrid algorithms to scalable memory architectures

The convergence rate of standard multigrid algorithms degenerates on problems with stretched grids or anisotropic operators. The usual cure for this is the use of line or plane relaxation. However, multigrid algorithms based on line and plane relaxation have limited and awkward parallelism and are quite difficult to map effectively to highly parallel architectures. Newer multigrid algorithms that overcome anisotropy through the use of multiple coarse grids rather than line relaxation are better suited to massively parallel architectures because they require only simple point-relaxation smoothers. The parallel implementation of a V-cycle multiple semi-coarsened grid (MSG) algorithm or distributed-memory architectures such as the Intel iPSC/860 and Paragon computers is addressed. The MSG algorithms provide two levels of parallelism: parallelism within the relaxation or interpolation on each grid and across the grids on each multigrid level. Both levels of parallelism must be exploited to map these algorithms effectively to parallel architectures. A mapping of an MSG algorithm to distributed-memory architectures that demonstrate how both levels of parallelism can be exploited is described. The results is a robust and effective multigrid algorithm for distributed-memory machines.

Overman, Andrea↗