Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distributed control networks”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Topology-Agnostic, Scalable, Self-Healing, and Cost-Aware Protection of Microgrids

Most microgrid protection schemes found in published literature suffer from a lack of generality in that they work well for the assumed topology, including type and placement of sources. Other generic protection schemes tend to be too complicated, too expensive, or both. To overcome these draw- backs, a topology-agnostic, scalable, and cost-aware protection based on fundamental principles that work in the presence of high penetration of inverter-based resources (IBRs) is developed and tested in this paper. Here, the protection system also implements stable automatic reconfiguration of the healthy sections of the system after clearance of fault, thus increasing resilience by self- healing. To achieve this ambitious goal, stable inverter models are developed that operate in unbalanced networks in grid-connected and islanded modes, even with 100% IBRs, share power without conflicting controls, and can ride through faults while limiting fault currents. The scheme is tested for primary and backup protection and reconfiguration on the IEEE 123-node feeder in grid-connected and islanded modes with 15 IBRs connected to the system.

42 ENGINEERING↗

Electric Access System Enhancement (EASE): Assessment of a Distributed Energy Resource Management System for Enabling Dynamic Hosting Capacity

The Electric Access System Enhancement (EASE) project demonstrated a scalable, interoperable, and cost-effective means of integrating high penetration of distributed energy resources (DERs). The control architecture developed leveraged a Distributed Energy Resource Management System, Distribution System Operator for transacting energy, and 3rd Party DER Aggregator platform. The project identified ways to enhance the customer interconnection process to the grid and improve access to information from DERs and optimize the usage of DERs to provide energy services in a simulated day-ahead shadow market while maintain grid reliability. By integrating these capabilities into a scalable system of systems, the DSO can effectively balance DER generation and customer demand on the distribution network. This capability allows the grid to host more DER than traditionally possible on wires alone. Hosting more DER has the added benefit of supplying increased demand growth, sometimes beyond the capacity limits of the distribution network itself. This is known as a dynamic hosting capacity, which could help utilities manage the forecasted growth in electricity demand as California switch to electric vehicles and appliances. This could help to establish energy storage and PV generation as a “pseudo firm” generation resource mix if managed appropriately and provide sufficient resource adequacy for distribution capacity upgrade deferrals.

14 SOLAR ENERGY↗

Analysis of Phosphonic Acids: Validation of Semi-Volatile Analysis by HPLC-MS/MS by EPA Method MS999

The Environmental Protection Agency's (EPA) Region 5 Chicago Regional Laboratory (CRL) developed a method titled Analysis of Diisopropyl Methylphosphonate, Ethyl Hydrogen Dimethylamidophosphate, Isopropyl Methylphosphonic Acid, Methylphosphonic Acid, and Pinacolyl Methylphosphonic Acid in Water by Multiple Reaction Monitoring Liquid Chromatography/Tandem Mass Spectrometry: EPA Version MS999. This draft standard operating procedure (SOP) was distributed to multiple EPA laboratories and to Lawrence Livermore National Laboratory, which was tasked to serve as a reference laboratory for EPA's Environmental Reference Laboratory Network (ERLN) and to develop and validate analytical procedures. The primary objective of this study was to validate and verify the analytical procedures described in EPA Method MS999 for analysis of the listed phosphonic acids and surrogates in aqueous samples. The gathered data from this validation study will be used to: (1) demonstrate analytical method performance; (2) generate quality control acceptance criteria; and (3) revise the SOP to provide a validated method that would be available for use during a homeland security event. The data contained in this report will be compiled, by EPA CRL, with data generated by other EPA Regional laboratories so that performance metrics of EPA Method MS999 can be determined.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Data distribution satellite

A description is given of a data distribution satellite (DDS) system. The DDS would operate in conjunction with the tracking and data relay satellite system to give ground-based users real time, two-way access to instruments in space and space-gathered data. The scope of work includes the following: (1) user requirements are derived; (2) communication scenarios are synthesized; (3) system design constraints and projected technology availability are identified; (4) DDS communications payload configuration is derived, and the satellite is designed; (5) requirements for earth terminals and network control are given; (6) system costs are estimated, both life cycle costs and user fees; and (7) technology developments are recommended, and a technology development plan is given. The most important results obtained are as follows: (1) a satellite designed for launch in 2007 is feasible and has 10 Gb/s capacity, 5.5 kW power, and 2000 kg mass; (2) DDS features include on-board baseband switching, use of Ku- and Ka-bands, multiple optical intersatellite links; and (3) system user costs are competitive with projected terrestrial communication costs.

Price, Kent M.↗

Improving Search Algorithms by Using Intelligent Coordinates

We consider algorithms that maximize a global function G in a distributed manner, using a different adaptive computational agent to set each variable of the underlying space. Each agent eta is self-interested; it sets its variable to maximize its own function g (sub eta). Three factors govern such a distributed algorithm's performance, related to exploration/exploitation, game theory, and machine learning. We demonstrate how to exploit alI three factors by modifying a search algorithm's exploration stage: rather than random exploration, each coordinate of the search space is now controlled by a separate machine-learning-based player engaged in a noncooperative game. Experiments demonstrate that this modification improves simulated annealing (SA) by up to an order of magnitude for bin packing and for a model of an economic process run over an underlying network. These experiments also reveal interesting small-world phenomena.

Wolpert, David H.↗

Peer-to-peer architectures for exascale computing : LDRD final report.

The goal of this research was to investigate the potential for employing dynamic, decentralized software architectures to achieve reliability in future high-performance computing platforms. These architectures, inspired by peer-to-peer networks such as botnets that already scale to millions of unreliable nodes, hold promise for enabling scientific applications to run usefully on next-generation exascale platforms ({approx} 10{sup 18} operations per second). Traditional parallel programming techniques suffer rapid deterioration of performance scaling with growing platform size, as the work of coping with increasingly frequent failures dominates over useful computation. Our studies suggest that new architectures, in which failures are treated as ubiquitous and their effects are considered as simply another controllable source of error in a scientific computation, can remove such obstacles to exascale computing for certain applications. We have developed a simulation framework, as well as a preliminary implementation in a large-scale emulation environment, for exploration of these 'fault-oblivious computing' approaches. High-performance computing (HPC) faces a fundamental problem of increasing total component failure rates due to increasing system sizes, which threaten to degrade system reliability to an unusable level by the time the exascale range is reached ({approx} 10{sup 18} operations per second, requiring of order millions of processors). As computer scientists seek a way to scale system software for next-generation exascale machines, it is worth considering peer-to-peer (P2P) architectures that are already capable of supporting 10{sup 6}-10{sup 7} unreliable nodes. Exascale platforms will require a different way of looking at systems and software because the machine will likely not be available in its entirety for a meaningful execution time. Realistic estimates of failure rates range from a few times per day to more than once per hour for these platforms. P2P architectures give us a starting point for crafting applications and system software for exascale. In the context of the Internet, P2P applications (e.g., file sharing, botnets) have already solved this problem for 10{sup 6}-10{sup 7} nodes. Usually based on a fractal distributed hash table structure, these systems have proven robust in practice to constant and unpredictable outages, failures, and even subversion. For example, a recent estimate of botnet turnover (i.e., the number of machines leaving and joining) is about 11% per week. Nonetheless, P2P networks remain effective despite these failures: The Conficker botnet has grown to {approx} 5 x 10{sup 6} peers. Unlike today's system software and applications, those for next-generation exascale machines cannot assume a static structure and, to be scalable over millions of nodes, must be decentralized. P2P architectures achieve both, and provide a promising model for 'fault-oblivious computing'. This project aimed to study the dynamics of P2P networks in the context of a design for exascale systems and applications. Having no single point of failure, the most successful P2P architectures are adaptive and self-organizing. While there has been some previous work applying P2P to message passing, little attention has been previously paid to the tightly coupled exascale domain. Typically, the per-node footprint of P2P systems is small, making them ideal for HPC use. The implementation on each peer node cooperates en masse to 'heal' disruptions rather than relying on a controlling 'master' node. Understanding this cooperative behavior from a complex systems viewpoint is essential to predicting useful environments for the inextricably unreliable exascale platforms of the future. We sought to obtain theoretical insight into the stability and large-scale behavior of candidate architectures, and to work toward leveraging Sandia's Emulytics platform to test promising candidates in a realistic (ultimately {ge} 10{sup 7} nodes) setting. Our primary example applications are drawn from linear algebra: a Jacobi relaxation solver for the heat equation, and the closely related technique of value iteration in optimization. We aimed to apply P2P concepts in designing implementations capable of surviving an unreliable machine of 10{sup 6} nodes.

99 GENERAL AND MISCELLANEOUS↗

Impacts of Pore Network-Scale Wettability Heterogeneity on Immiscible Fluid Displacement: A Micromodel Study

The mixed-wet nature of reservoir formations imposes a wide range of rock wettability from strong resident-fluid wetting to strong invading-fluid wetting. The characteristics of two-phase flow in porous media composed of mixed-wetting surfaces remain poorly understood. In this study, we investigated the displacement of resident ethylene glycol (EG) by hexane in two mixed-wet micromodels of identical 2.5-D geometry heterogeneity, with uniformly or heterogeneously distributed patches strongly wetting to hexane. These patches are mixed among pores with unaltered EG-wetting surfaces. Along with control tests in the originally EG-wet micromodel, here we show the classic fingering and transitions in flow regimes at $logCa$ (capillary number) from -7.2 to -3.9. Moreover, pore-scale distributions of wettability and their spatial correlation influence displacement efficiency. In the two mixed-wet micromodels, we found (a) an increase of steady-state hexane saturation at the end of experiments by up to 0.12 in the capillary fingering regime and a decrease of at most by 0.06 in the viscous fingering regime, compared to the EG-wet micromodel, and (b) dispersed and fragmented hexane distribution after displacement. Brine drainage during supercritical CO 2 (scCO 2 ) injections in these micromodels occurs with lower wettability contrasts, and under similar viscosity ratios and interfacial tensions resulted in higher displacement efficiency relative to displacement of EG by hexane. While mixed-wettability can enhance displacement efficiency compared to uniform wettability, the dynamics of immiscible fluids in strong mixed-wet reservoirs are expected to be less pronounced in contributing to the efficiency of geological CO 2 sequestration, oil recovery, and remediation of hydrocarbon-contaminated aquifers.

2.5-D micromodel↗

Secure VM for Monitoring Industrial Process Controllers

In this paper, we examine the biological immune system as an autonomic system for self-protection, which has evolved over millions of years probably through extensive redesigning, testing, tuning and optimization process. The powerful information processing capabilities of the immune system, such as feature extraction, pattern recognition, learning, memory, and its distributive nature provide rich metaphors for its artificial counterpart. Our study focuses on building an autonomic defense system, using some immunological metaphors for information gathering, analyzing, decision making and launching threat and attack responses. In order to detection Stuxnet like malware, we propose to include a secure VM (or dedicated host) to the SCADA Network to monitor behavior and all software updates. This on-going research effort is not to mimic the nature but to explore and learn valuable lessons useful for self-adaptive cyber defense systems.

99 GENERAL AND MISCELLANEOUS↗

Molecular Dynamics Simulation of Hydration and Swelling of Mixed-Layer Clays in the Presence of Carbon Dioxide

Swelling of clay minerals is a prime anomaly that is relevant to many problems in geoscience, oil and gas reservoirs, geophysics, and engineering. The phenomenon is even more complex when carbon dioxide is also present. Since sequestration of CO 2 in sedimentary rock has been under active consideration as a way of alleviating the increasing concerns over climate change for which CO 2 is a main culprit, studying swelling of clays minerals in the presence of CO 2 has taken on added urgency. The swelling changes the permeability and porosity of porous formations, which in turn may lead to a reactivation of dormant fractures, triggering seismic activities, and opening up new pathways for CO 2 to return to the porous formations’ surface. Although the large majority of sedimentary rocks contain various types of mixed-layer clays (MLCs) with intermixed stacking sequences of several types of distinct layers within a single crystal, the vast majority of the past experimental and computational studies of the swelling was focused on pure clays. We present the results of extensive molecular dynamics simulation of hydration and swelling of illite-montmorillonite (I-MMT) MLCs, the most common type of mixed clays, in the presence of both water and CO 2 and various combinations of interlayer cations, Na + and K + . To understand the differences with pure clays, we also report on the same phenomenon in the MMT only. At low CO 2 concentrations in Na-MMT, which has its layers’ charge concentrated in its octahedral sheet, weak ion–surface interactions result in fully hydrated ions and, therefore, more extensive swelling than in I-MMT. Without CO 2 , adsorption of the cations at the illite surface increases the hydrophobicity of its surface. Thus, in the asymmetric interlayer of I-MMT, illite with stronger surface–ion interactions causes accumulation of cations near its surface, which limits their hydration and, therefore, controls swelling of the MLCs. Further inhibition of swelling of Na-MLC can be achieved by increasing the concentration of K + in the interlayer. At higher CO 2 concentrations, however, intercalation of water and CO 2 results in a completely different behavior, since in the 2W and 3W hydration states, the hydrophobicity of the MMT surface is stronger than that of illite. Thus, the density distributions of the intercalated molecules are considerably different from that with water only, which together with disruption of the water network by CO 2 reduces the difference between the extent of swelling of the MLC and pure MMT.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Towards a New Supply Chain Cybersecurity Risk Analysis Technique

Supply chain cyber-attacks, such as the SolarWinds Orion attack, are occurring with greater frequency. These attacks compromise a digital device before it is sent to customers, bypassing traditional security controls to remain persistent and undetected in operational environments. While supply chain attacks are prevalent, methods for analyzing the risk of these attacks are currently unavailable. This paper proposes new supply chain cyber-attack difficulty and risk metrics to evaluate the relative risk of an attack throughout the supply chain lifecycle. Difficulty metrics for each stakeholder in a digital device’s supply chain (e.g., hardware manufacturing, firmware development, software development, storage, and distribution entities) are calculated using scores from cybersecurity maturity questionnaires in a Bayesian Network leaky Noisy-MAX model. These difficulty metrics are then used to calculate an overall supply chain cyber-attack risk. Vulnerability and recoverability metrics are also proposed to evaluate the relative stakeholder influence in the attack risk. These proposed relative risk metrics enable continuous supply chain monitoring, provide decision-makers with information necessary for improved supplier selection, and help drive improvements in the cybersecurity posture of the stakeholders in their supply chain.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Artificial neural network application for space station power system fault diagnosis

This study presents a methodology for fault diagnosis using a Two-Stage Artificial Neural Network Clustering Algorithm. Previously, SPICE models of a 5-bus DC power distribution system with assumed constant output power during contingencies from the DDCU were used to evaluate the ANN's fault diagnosis capabilities. This on-going study uses EMTP models of the components (distribution lines, SPDU, TPDU, loads) and power sources (DDCU) of Space Station Alpha's electrical Power Distribution System as a basis for the ANN fault diagnostic tool. The results from the two studies are contrasted. In the event of a major fault, ground controllers need the ability to identify the type of fault, isolate the fault to the orbital replaceable unit level and provide the necessary information for the power management expert system to optimally determine a degraded-mode load schedule. To accomplish these goals, the electrical power distribution system's architecture can be subdivided into three major classes: DC-DC converter to loads, DC Switching Unit (DCSU) to Main bus Switching Unit (MBSU), and Power Sources to DCSU. Each class which has its own electrical characteristics and operations, requires a unique fault analysis philosophy. This study identifies these philosophies as Riddles 1, 2 and 3 respectively. The results of the on-going study addresses Riddle-1. It is concluded in this study that the combination of the EMTP models of the DDCU, distribution cables and electrical loads yields a more accurate model of the behavior and in addition yielded more accurate fault diagnosis using ANN versus the results obtained with the SPICE models.

Momoh, James A.↗

Magnetic Amplifier for Power Flow Control

GENI Project: ORNL is developing an electromagnet-based, amplifier-like device that will allow for complete control over the flow of power within the electric grid. To date, complete control of power flow within the grid has been prohibitively expensive. ORNL’s controller could provide a reliable, cost-effective solution to this problem. The team is combining two types of pre-existing technologies to assist in flow control, culminating in a prototype iron-based magnetic amplifier. Ordinarily, such a device would require expensive superconductive wire, but the magnetic iron core of ORNL’s device could serve as a low-cost alternative that is equally adept at regulating power flow.

ARPA-E↗

Global Phase and Magnitude Synchronization of Coupled Oscillators With Application to the Control of Grid-Forming Power Inverters

In this paper, we explore a new approach to synchronization of coupled oscillators. In contrast to the celebrated Kuramoto model, we do not work in polar coordinates and do not consider oscillations of fixed magnitude. We propose a synchronizing feedback based on relative state information and local measurements that induces consensus-like dynamics. We show that, under a mild stability condition, the combination of the synchronizing feedback with a decentralized magnitude control law renders the oscillators' almost globally asymptotically stable with respect to set points for the phase shift, frequency, and magnitude. We apply these result to rigorously solve an open problem in control of inverter-based ac power systems. In this context, the proposed control strategy can be implemented using purely local information, induces a grid-forming behavior, and ensures that a network of ac power inverters is almost globally asymptotically stable with respect to a prespecified solution of the ac power-flow equations. Moreover, we show that the controller exhibits a droop-like behavior around the standard operating point, thus, making it backward compatible with the existing power system operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nasa's Launch Communications Ground Segment for the 21st Century Florida Spaceport

The National Aeronautics and Space Administration (NASA) Near Earth Network (NEN) Project is implementing a new launch communications ground segment to provide services for the next generation of human and robotic space exploration systems. It will deliver unique and advanced capabilities to accelerate the transformation of Kennedy Space Center into a multi-user spaceport in cooperation with the United States Air Force (USAF). The project has leveraged commercial technologies and remote operations concepts matured in NASAs orbiting satellite ground systems to achieve dramatic lifecycle cost efficiencies as compared to the space shuttle-era ground segment. The purpose of this paper is to discuss the development history, capabilities and anticipated use cases of the NEN Launch Communications Segment (NEN LCS).The NASA Kennedy Space Center is co-located with the USAF Eastern Launch Range at Cape Canaveral, Florida. The USAF operates two launch communications ground stations, but they are not designed to transmit voice, commands or other data to the launch vehicle or astronauts. The bi-directional uplink-downlink communications responsibility for human missions has historically resided with the Goddard Space Flight Center in Greenbelt, Maryland. Several market analyses and feasibility studies investigating concepts to provide NASAs next generation launch communications services were performed during the Constellation Program prior to its cancellation in 2009, and as part of the Kennedy Space Centers follow-on efforts to transform itself into a 21st century multi-user spaceport. In 2012, the Kennedy Space Center and the USAF 45th Space Wing jointly led a study to analyze the market needs of current and future launch systems and assess the operational deficiencies of the Eastern Range infrastructure. The study team issued several recommendations, two of which ultimately became driving operational capability requirements for the NEN LCS: increased telemetry data rates of at least 20 Mbps, and S-band uplink capability. Additional capabilities identified in the requirements development process include spread spectrum modulation support, LDPC 12 and 78 error correction codes, support for IRIG-106 and CCSDS data formats, automated best source selection, and Space Link Extension (SLE) services for data distribution. The NEN LCS is comprised of two permanent ground stations, the new Kennedy Uplink Station (KUS) and refurbished Ponce de Leon (PDL) station. Both stations are remotely operated from the Global Monitor and Control Center at Wallops Flight Facility. This core architecture is extensible through host-tenant arrangements with the U.S. Air Force and deployable assets, enabling agile, tailored and robust solutions to meet the needs of civil, commercial or military customers. The NEN LCS has three use cases:1.To provide agile, tailored and robust launch communications solutions to Florida spaceport customers2.To provide orbital communications services to near-earth customers 3.To provide an experimental proving ground for Space Mobile Network concepts and technologies The NEN LCS driving mission is to support the bi-directional link with the Orion crew capsule and two 20 Mbps telemetry links from the Space Launch System core stage on Exploration Mission-1, the first integrated flight of NASAs flagship human exploration systems.

Roberts, Christopher J.↗

Structure, morphology and ionic conductivity of solid polymer electrolyte

Graphical abstract: Two-dimensional atomic force image of pure polyethylene oxide presents a crystallized network of regular spherulites developing spirals and branches of well distributed surface contours. Highlights: {yields} The incorporation of ceria significantly modifies the morphology of polyethylene oxide (PEO)-KI complex. {yields} The ionic conductivity increases by about two orders of magnitude by the addition of ceria nanoparticles. {yields} Ionic conductivity as a function of ceria concentration reveals two maxima. {yields} Grain boundary effect of nanofiller, strong Lewis acid-base interaction between PEO and nanosized ceria, change of conformation of PEO molecule and epitaxial effect of ceria nanoparticles control the ionic conductivity of composite polymer electrolyte. -- Abstract: Polyethylene oxide (PEO) complexed with potassium iodide (KI) is synthesized to investigate the ionic conductivity of alkaline based polymer electrolytes. The structural and morphological characterizations of the nanocomposite polymer electrolytes are performed by X-ray diffractometry (XRD), atomic force microscopy (AFM), differential scanning calorimetry (DSC) and Fourier transform infrared spectroscopy (FTIR) measurements. The ionic conductivity increases with the increase of KI concentration up to about 20 wt.%. The effect of nanosized ceria (CeO{sub 2} {approx} 10 nm) fillers on ionic conductivity in PEO-KI polymer electrolyte is also carried out, keeping PEO to KI wt.% ratio 80:20 and 85:15. The result reveals that the addition of ceria nanoparticles enhances the conductivity by two orders of magnitude. The presence of ceria at the highest concentration induces the same molecular environment within PEO chain as that of undoped PEO. Temperature dependence of ionic conductivity follows Arrhenius mechanism.

36 MATERIALS SCIENCE↗

Comparison of the combustion reactivity of TGA and drop tube furnace chars from a bituminous coal

This paper compares the reactivity of chars generated in a drop tube furnace (DTF) to those from TGA. The implications of devolatilization temperature, heating rate and residence time are considered. For the smaller particle size ranges of the bituminous coal investigated (ATC), optimized devolatilization procedures were used to generate corresponding TGA burnout rates between the two char types. However, with fractions of >75 {mu}m, the DTF chars showed an increased burnout propensity when moving from combustion regime II to combustion regime III. Scanning electron microscope (SEM) images and internal surface areas indicate that this is because of incompatible char morphologies. Thus, while chars produced under the conditions of TGA pyrolysis strongly resemble raw coal and display an undeveloped pore network; the DTF chars are highly porous, extensively swollen and possess considerably larger internal surface areas. Subsequently, char burnout variability was quantified, with the reactivity distribution for the DTF samples found to be up to an order of magnitude more significant than for the TGA chars. This is attributed to a fluctuating devolatilization environment on the DTF. Finally, a TGA study observed a robust particle size based compensation effect for the TGA chars, with the relative reaction rates and activation energies demonstrating the presence of internal diffusion control. However this phenomenon was partly alleviated for the DTF chars, since their higher porosities reduce mass transfer restrictions. Moreover, it should be realized that DTF char fractions of <38 {mu}m, including those required to ensure true intrinsic control under the investigated burnout conditions, cannot be produced directly. This is because of bridging and sloughing in the DTF's screw-feeder. Instead, such samples must be created by grinding larger particles, which destroys the char's existing porosity. 60 refs., 9 figs., 5 tabs.

01 COAL, LIGNITE, AND PEAT↗

A DDS-Based Energy Management Framework for Small Microgrid Operation and Control

The smart grid is seen as a power system with realtime communication and control capabilities between the consumer and the utility. This modern platform facilitates the optimization in energy usage based on several factors including environmental, price preferences, and system technical issues. In this paper a real-time energy management system (EMS) for microgrids or nanogrids was developed. The developed system involves an online optimization scheme to adapt its parameters based on previous, current, and forecasted future system states. The communication requirements for all EMS modules were analyzed and are all integrated over a data distribution service (DDS) Ethernet network with appropriate quality of service (QoS) profiles. In conclusion, the developed EMS was emulated with actual residential energy consumption and irradiance data from Miami, Florida and proved its effectiveness in reducing consumers’ bills and achieving flat peak load profiles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Throughput Measurements and Profile Analysis of Cloud Networks

Cloud networks utilize virtual connections to connect virtual machines distributed across cloud sites. They are increasingly deployed due to flexible provisioning using software and cost-effectiveness in not requiring to build physical network infrastructure. However, their extensive virtualization makes it unclear how well the established practices of conventional networks translate to them. Here, we study throughput measurements over a Google Cloud network using a matching hardware emulated conventional network, which provide production and exploratory conditions, respectively. The measurements span connections representing local, cross-continental and around the Earth distances. We study the effects of parallel flows, congestion control algorithms and retransmissions on the network throughput profile expressed as a function of RTT. We compare the throughput profile of Google Cloud network with those of emulated network under various loss conditions, including those too disruptive or expensive in the former. Our analysis based on the concave-convex shape and utilization-concavity coefficients of throughput profiles indicates an overall agreement of performance between the two networks, thereby justifying the use of conventional network emulations to analyze cloud networks. In terms of practical use, our study establishes that BBR and BBRv2 alpha TCP achieve higher throughput compared to loss-based congestion control algorithms under most network configurations, especially, under losses at large RTT.

Phanekham, Derek [Southern Methodist Univ., Dallas↗