Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cryogenics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

The Relativistic Heavy Ion Collider (RHIC) cryogenic system at Brookhaven National Laboratory: Review of the modifications and upgrades since 2002 and planned improvements.

Brookhaven National Laboratory continues its multi-year program to improve the operational efficiency, reliability, and stability of the cryogenic system, which also resulted in an improved beam availability of the Relativistic Heavy Ion Collider (RHIC). This paper summarizes the work and changes made after each phase over the past four years to the present, as well as proposed future improvements. Power usage dropped from an initial 9.4 MW to the present 5.1 MW and is expected to drop below 5 MW after the completion of the remaining proposed improvements. The work proceeded in phases, balancing the Collider's schedule of operation, time required for the modifications and budget constraints. The main changes include process control, compressor oil removal and management, elimination of the use of cold compressors and two liquid-helium storage tanks, insulation of the third liquid-helium storage tank, compressor-bypass flow reduction and the addition of a load turbine (Joule-Thomson ex

74 ATOMIC AND MOLECULAR PHYSICS↗

RECENT PROGRESS IN DYNAMIC PROCESS SIMULATION OF CRYOGENIC REFRIGERATORS

At the CEC 2005 a paper with the title 'Helium refrigerator design for pulsed heat load in Tokamaks' was presented. That paper highlighted the control requirements for cryogenic refrigerators to cope with the expected load variations of future nuclear fusion reactors. First dynamic computer simulations have been presented.In the mean time, the computer program is enhanced and a new series of process simulations are available. The new program considers not only the heat flows and the temperature variations within the heat exchangers, but also the variation of mass flows and pressure drops. The heat transfer numbers now are calculated in dependence of the flow speed and the gas properties. PI-controllers calculate the necessary position of specific valves for maintaining pressures, temperatures and the rotation speed of turbines.Still unsatisfactory is the fact, that changes in the process arrangement usually are attended by adjustments in the program code. It is the main objective of the next step of development a more flexible code which enables that any user defined process arrangements can be assembled by input data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Cryogenic Dark Matter Search (CDMS) experiment: Results, status and perspective

The Cryogenic Dark Matter Search experiment (CDMS) is using Phonon+Ionization detectors to search for Dark Matter in the form of Weakly Interactive Massive Particles (WIMPs). We report on new results from the operation of CDMS five 'towers' at Soudan underground laboratory. With new and more massive detectors, SuperCDMS project has been started since March 2009. We report on the current status of SuperCDMS and its perspective.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scientific Applications and Promise of Cryogenic Detector Arrays

During the past year, the first results from a new generation of instruments based on kilopixel-scale arrays of cryogenic detectors have been released. I will review the history of low temperature detector arrays which has enabled this development, the science which has driven this rapid progress, describe the instruments now in operation and their initial scientific results, and speculate on the developments we may see in the next decade.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Properties of a nanodielectric cryogenic resin

Physical properties of a nanodielectric composed of in situ synthesized titanium dioxide (TiO{sub 2}) nanoparticles ({le} 5 nm in diameter) and a cryogenic resin are reported. The dielectric losses were reduced by a factor of 2 in the nanocomposite, indicating that the presence of small TiO{sub 2} nanoparticles restricted the mobility of the polymer chains. Dielectric breakdown data of the nanodielectric was distributed over a narrower range than that of the unfilled resin. The nanodielectric had 1.56 times higher 1% breakdown probability than the resin, yielding 0.64 times thinner insulation thickness for the same voltage level, which is beneficial in high voltage engineering.

36 MATERIALS SCIENCE↗

DEVELOPMENT OF A SIMULATION CODE FOR A COOL-DOWN PROCESS OF THE CRYOGENIC HYDROGEN SYSTEM

Supercritical hydrogen with a pressure of 1.5 MPa and a temperature of 20 K has been selected as a moderator material in an intense spallation neutron source (JSNS), which is one of main experimental facilities in J-PARC. The cryogenic hydrogen system, in which a hydrogen circulation system is cooled by a helium refrigerator with the refrigeration power of 6.45 kW at 15.5 K, has been designed to provide the supercritical hydrogen to the moderator and to remove the nuclear heating generated there. In this study, we have developed a simulation code that predicts temperature behaviors in the hydrogen circulation system during its cool-down process. Cool-down process analyses have been performed, and an operational method for the cool-down process has been studied. The analytical results indicate that the hydrogen circulation system would be able to be cooled down to 18 K within 19 hours.

42 ENGINEERING↗

Outgassing and degradation of polyimide induced by swift heavy ion irradiation at cryogenic temperature

Polyimide foils were irradiated with energetic Kr (740 MeV) and Pb (890 MeV) ions at cryogenic temperature (12 K). Beam-induced degradation processes were monitored by residual gas analysis and online infrared spectroscopy. The outgassing components observed at low irradiation temperatures differ in quantity but are similar in mass distribution to those identified at room temperature exposure. Besides CO as major volatile fragment, a significant contribution of short hydrocarbons like C{sub 2}H{sub x} is released. In situ infrared spectroscopy indicates accumulation of CO and CO{sub 2} molecules at 12 K in the foils. During heat-up cycles, most of these frozen gases become mobile and outgas at a temperature between 35 and 55 K. The study is motivated by the application of polyimide foils as insulating material in high radiation environment of the future accelerator facility for antiproton and ion research (FAIR).

36 MATERIALS SCIENCE↗

Note: New design of a cryogenic linear radio frequency multipole trap

A new design of a cryogenic linear 22-pole ion trap has been constructed and tested. It is essentially a copper housing to which opposite inner walls two electrode sets are attached via sapphire insulators. These stainless steel electrodes are electroformed in one piece to guarantee good heat conduction. Connected to an external coil, they form an LC-circuit of about 19 MHz resonance frequency. This circuit is excited with a rf power supply made of a commercial digital synthesizer followed by a 10 W amplifier. Buffer gas-cooled H{sub 2}D{sup +} ions have been stored in this trap at a nominal trap temperature of 14 K. Spectroscopy of the ions confirmed that the kinetic (Doppler) temperature is in reasonable agreement with this value.

43 PARTICLE ACCELERATORS↗

Cryogenic Permanent Magnet Undulators

For an in-vacuum undulator operated at small gaps the permanent magnet material needs to be highly resistant to possible electron beam exposure. At room temperature, one generally uses Sm{sub 2}Co{sub 17} or high coercivity NdFeB magnets at the expense of a limited field performance. In a cryogenic permanent magnet undulator (CPMU), at a temperature of around 150 K, any NdFeB grade reveals a coercivity large enough to be radiation resistant. In particular, very high remanence NdFeB material can be used to build undulators with enhanced field and X-ray brilliance at high photon energy provided that the pre-baking of the undulator above 100 deg. C can be eliminated. The ESRF has developed a full scale 2 m long CPMU with a period of 18 mm. This prototype has been in operation on the ID6 test beamline since January 2008. A significant effort was put into the characterization of NdFeB material at low temperature, the development of dedicated magnetic measurement systems and cooling methods. The measured heat budget with beam is found to be larger than expected without compromising the smooth operation of the device. Leading on from this first experience, new CPMUs are currently being considered for the upgrade of the ESRF.

43 PARTICLE ACCELERATORS↗

High-accuracy X-ray detector calibration based on cryogenic radiometry

Cryogenic electrical substitution radiometers (ESRs) are absolute thermal detectors, based on the equivalence of electrical power and radiant power. Their core piece is a cavity absorber, which is typically made of copper to achieve a short response time. At higher photon energies, the use of copper prevents the operation of ESRs due to increasing transmittance. A new absorber design for hard X-rays has been developed at the laboratory of the Physikalisch-Technische Bundesanstalt (PTB) at the electron storage ring BESSY II. The Monte Carlo simulation code Geant4 was applied to optimize its absorptance for photon energies of up to 60 keV. The measurement of the radiant power of monochromatized synchrotron radiation was achieved with relative standard uncertainties of less than 0.2 %, covering the entire photon energy range of three beamlines from 50 eV to 60 keV. Monochromatized synchrotron radiation of high spectral purity is used to calibrate silicon photodiodes against the ESR for photon energies up to 60 keV with relative standard uncertainties below 0.3 %. For some silicon photodiodes, the photocurrent is not linear with the incident radiant power.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cryogenic RF Material Testing with a High-Q Copper Cavity

An X-band RF cryogenic material testing system has been developed in the past few years. This system employs a high-Q copper cavity with an interchangeable flat bottom working under a TE{sub 013} like mode. By measuring the cavity Qs with a network analyzer, the system can characterize the surface resistance of different samples at different temperatures. Using a 50 MW 2{mu}s pulsed klystron, the system can measure the quenching H field for superconducting samples, up to 300-400 mT. In this paper, we will present the most recent developments of the system and testing results.

36 MATERIALS SCIENCE↗

Investigation on the Surface Integrity and Tool Wear in Cryogenic Machining

This work aimed to study the influences of cryogenic cooling on tool wear, comparing it to dry machining during on the surface integrity of test circular steel SAE 52100 hardened to 62 HRC, during the turning of the face, with the use of special PcBN, using liquid nitrogen with cooler. The surface integrity parameters analyzed were: surface roughness and white layer and tool wear. The results of the present work indicated reduction in tool wear, which enhance the tool life.

36 MATERIALS SCIENCE↗

Cryogenic apparatus for study of near-field heat transfer

For bodies spaced in vacuum at distances shorter than the wavelength of the thermal radiation, radiative heat transfer substantially increases due to the contribution of evanescent electromagnetic waves. Experimental data on heat transfer in near-field regime are scarce. We have designed a cryogenic apparatus for the study of heat transfer over microscopic distances between metallic and non-metallic surfaces. Using a mechanical positioning system, a planeparallel gap between the samples, concentric disks, each 35 mm in diameter, is set and varied from 10{sup 0} to 10{sup 3} {mu}m. The heat transferred from the hot (10 - 100 K) to the cold sample ({approx}5 K) sinks into a liquid helium bath through a thermal resistor, serving as a heat flux meter. Transferred heat power within {approx}2 nW/cm{sup 2} and {approx}30 {mu}W/cm{sup 2} is derived from the temperature drop along the thermal resistor. For tungsten samples, the distance of the near-field effect onset was inversely proportional to temperature and the heat power increase was observed up to three orders of magnitude greater than the power of far-field radiative heat transfer.

42 ENGINEERING↗

Compact cryogenic source of periodic hydrogen and argon droplet beams for relativistic laser-plasma generation

We present a cryogenic source of periodic streams of micrometer-sized hydrogen and argon droplets as ideal mass-limited target systems for fundamental intense laser-driven plasma applications. The highly compact design combined with a high temporal and spatial droplet stability makes our injector ideally suited for experiments using state-of-the-art high-power lasers in which a precise synchronization between the laser pulses and the droplets is mandatory. We show this by irradiating argon droplets with multi-terawatt pulses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Short-lived Rn-222 daughters in cryogenic liquids

In this paper a detection method of α emitters from {sup 222}Rn decay chain, present in cryogenic liquids, using bare Si-PIN diodes immersed in the liquids is presented. Properties of ionized {sup 222}Rn daughters deduced from conducted measurements are outlined. Life-time of positive ions was found to be of the order of 10 s, and nonzero content of electronegative ions was observed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characteristics of a liquid-helium-free calibration apparatus for cryogenic thermometers

Closed-cycle Joule-Thomson (JT) cryocoolers have been developed at National Metrology Institute of Japan (NMIJ)/National Institute of Advanced Industrial Science and Technology (AIST) with the aim of realizing a liquid-helium-free calibration apparatus for cryogenic thermometers between 0.65 K and 25 K. The latest JT cryocooler at NMIJ/AIST consists of a {sup 3}He JT cooling circuit and a pulse tube mechanical refrigerator. The characteristics of the apparatus including a residual gas analysis of the JT cooling circuit are presented in this paper. Currently the initial cool-down is performed using a heat-exchange gas. It normally takes about 30 h to reduce the temperature from room temperature to 5 K at the thermometer comparison block of the apparatus. The correct timing of the removal of the heatexchange gas is important for the efficient operation of the apparatus. Incomplete removal of the heat-exchange gas induces excess heat load on the apparatus and thermal disturbances. Some examples of abrupt temperature bursts are discussed in this paper. Mechanical refrigerators generate cyclic mechanical vibrations, and precision resistance thermometers are usually very sensitive to a mechanical vibration. The measured vibration level of the developed apparatus is reported. The damage to the apparatus due to the magnitude 9.0 earthquake on March 11, 2011, and possible countermeasures in the case of future earthquakes are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of the failures and corrective actions for the LHC cryogenics radiation tolerant electronics and its field instruments

The LHC cryogenic system radiation tolerant electronics and their associated field instruments have been in nominal conditions since before the commissioning of the first LHC beams in September 2008. This system is made of about 15’000 field instruments (thermometers, pressure sensors, liquid helium level gauges, electrical heaters and position switches), 7’500 electronic cards and 853 electronic crates. Since mid-2008 a software tool has been deployed, this allows an operator to report a problem and then lists the corrective actions. The tool is a great help in detecting recurrent problems that may be tackled by a hardware or software consolidation. The corrective actions range from simple resets, exchange of defective equipment, repair of electrical connectors, etc. However a recurrent problem that heals by itself is present on some channels. This type of fault is extremely difficult to diagnose and it appears as a temporary opening of an electrical circuit; its duration can range from a few minutes to several months. This paper presents the main type of problems encountered during the last four years, their evolution over time, the various hardware or software consolidations that have resulted and whether they have had an impact in the availability of the LHC beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast imaging of intact and shattered cryogenic neon pellets

Compact condensed-matter injection technologies are increasingly used in magnetic fusion. One recent application is in disruption mitigation. An imaging system with less-than-100-µm- and sub-µs-resolution is described and used to characterize intact and shattered cryogenic neon pellets. Shattered pellets contain fine particles ranging from tens of µm to about 7 mm. Time-of-flight analyses indicate that pellets could slow down if hitting the wall of the guide tube. Fast high-resolution imaging systems are thus useful to neon and other condensed-matter injector development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗