Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “count data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Using Wi-Fi Location-Based Services (LBS) for Commercial Building Occupancy Sensing

From May 2019 through October 2022, this DOE-funded project investigated and demonstrated the use of Wi-Fi Location-Based Services (LBS) to perform occupancy sensing in commercial buildings. Wi-Fi LBS can be used to detect the presence of Wi-Fi enabled mobile devices and laptops that accompany occupants as they move through the building. These signals can be used to determine occupant presence, head count, and location. When integrated with the building automation system, this emerging technology approach can be used to manage other connected systems such as lighting and HVAC to reduce energy usage in the building and improve occupant comfort. An open source location detection algorithm was developed, which uses data collected from three or more Wi-Fi access points to determine the presence and estimate the location of mobile devices and laptops. Access points can detect Wi-Fi enabled devices even if they are not connected to the existing Wi-Fi network. Building occupancy is determined based on the presence, location, and movement of these devices through the space. From lab and small-scale in-situ testing, the Location Detection Algorithm (LDA) was found to be accurate to within 10 feet and could be further refined by tuning the algorithm for the specific space characteristics such as layout and obstructions (walls, furniture, etc.). An open source method to integrate the occupancy data with existing building automations systems was investigated. The Wi-Fi occupancy sensing approach was then demonstrated and validated at two commercial buildings located in Minnesota and Wisconsin.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Active Interrogation using Photofission Technique for Nuclear Materials Control and Accountability

Innovative systems with increased sensitivity and resolution are in great demand to detect diversion and to prevent misuse in support of nuclear materials management for the U.S. fuel cycle. Nuclear fission is the most important multiplicative process involved in non-destructive active interrogation. This process produces the most easily recognizable signature for nuclear materials. In addition to thermal or high-energy neutrons, high-energy gamma rays can also excite a nucleus and cause fission through a process known as photofission. Electron linear accelerators (linacs) are widely used as the interrogating photon sources for inspection methods involving photofission technique. After photofission reactions, prompt signals are much stronger than the delayed signals, but it is difficult to quantify them in practical measurements. Delayed signals are easily distinguishable from the interrogating radiation. Linac-based, advanced inspection techniques utilizing the delayed signals after photofission have been extensively studied for homeland security applications. Previous research also showed that a unique delayed gamma ray energy spectrum exists for each fissionable isotope. In this work, high-energy delayed γ-rays were demonstrated to be signatures for detection, identification, and quantification of special nuclear materials. Such γ-rays were measured in between linac pulses using independent data acquisition systems. A list-mode system was developed to measure low-energy delayed γ-rays after irradiation. Photofission product yields of 238 U and 239 Pu were determined based on the measured delayed γ-ray spectra. The differential yields of delayed γ-rays were also proven to be able to discriminate nuclear from non-nuclear materials. The measurement outcomes were compared with Monte Carlo simulation results. It was demonstrated that the current available codes have capabilities and limitations in the simulation of photofission process. A two-fold approach was used to address the high-rate challenge in used nuclear fuel assay based on photofission technique. First, a standard HPGe preamplifier was modified to improve its capabilities in high-rate pulsed photofission environment. Second, advanced pulse processing algorithms were shown to greatly improve throughput rate without large sacrifice in energy resolution at ultra-high input count rate. Two customized gamma spectroscopy systems were also developed in real-time on FPGAs. They were shown to have promising performance matching available commercial units.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-Dose Hyper-Radiosensitivity Is Not a Common Effect in Normal Asynchronous and G2-Phase Fibroblasts of Cancer Patients

Purpose: In our previous study, using the micronucleus assay, a low-dose hyper-radiosensitivity (HRS)-like phenomenon was observed for normal fibroblasts of 2 of the 40 cancer patients investigated. In this article we report, for the first time, the survival response of primary fibroblasts from 25 of these patients to low-dose irradiation and answer the question regarding the effect of G2-phase enrichment on HRS elicitation. Methods and Materials: The clonogenic survival of asynchronous as well as G2-phase enriched fibroblast populations was measured. Separation of G2-phase cells and precise cell counting was performed using a fluorescence-activated cell sorter. Sorted and plated cells were irradiated with single doses (0.1-4 Gy) of 6-MV x-rays. For each patient, at least 4 independent experiments were performed, and the induced-repair model was fitted over the whole data set to confirm the presence of HRS effect. Results: The HRS response was demonstrated for the asynchronous and G2-phase enriched cell populations of 4 patients. For the rest of patients, HRS was not defined in either of the 2 fibroblast populations. Thus, G2-phase enrichment had no effect on HRS elicitation. Conclusions: The fact that low-dose hyper-radiosensitivity is not a common effect in normal human fibroblasts implies that HRS may be of little consequence in late-responding connective tissues with regard to radiation fibrosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of natural gamma background radiation on portal monitor radioisotope unmixing

It is well known that national security relies on several layers of protection. One of the most important is the traffic control at borders and ports that exploits Radiation Portal Monitors (RPMs) to detect and deter potential smuggling attempts. Most portal monitors rely on plastic scintillators to detect gamma rays. Despite their poor energy resolution, their cost effectiveness and the possibility of growing them in large sizes make them the gamma-ray detector of choice in RPMs. Unmixing algorithms applied to organic scintillator spectra can be used to reliably identify the bare and unshielded radionuclides that triggered an alarm, even with fewer than 1000 detected counts and in the presence of two or three nuclides at the same time. In this work, we experimentally studied the robustness of a state-of-the-art unmixing algorithm to different radiation background spectra, due to varying atmospheric conditions, in the 16 °C to 28 °C temperature range. In the presence of background, the algorithm is able to identify the nuclides present in unknown radionuclide mixtures of three nuclides, when at least 1000 counts from the sources are detected. With fewer counts available, we found larger differences of approximately 35.9% between estimated nuclide fractions and actual ones. In these low count rate regimes, the uncertainty associated by our algorithm with the identified fractions could be an additional valuable tool to determine whether the identification is reliable or a longer measurement to increase the signal-to-noise ratio is needed. Moreover, the algorithm identification performances are consistent throughout different data sets, with negligible differences in the presence of background types of different intensity and spectral shape.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Screening of Therapeutic Agents for COVID-19 Using Machine Learning and Ensemble Docking Studies

The current pandemic demands a search for therapeutic agents against the novel coronavirus SARS-CoV-2. In this work, we present an efficient computational strategy that combines machine learning (ML)-based models and high-fidelity ensemble docking studies to enable rapid screening of possible therapeutic ligands. Targeting the binding affinity of molecules for either the isolated SARS-CoV-2 S-protein at its host receptor region or the S-protein:human ACE2 interface complex, we screen ligands from drug and biomolecule data sets that can potentially limit and/or disrupt the host-virus interactions. Top scoring one hundred eighty-seven ligands (with 75 approved by the Food and Drug Administration) are further validated by all atom docking studies. Important molecular descriptors ( 2 χ n , topological surface area, and ring count) and promising chemical fragments (oxolane, hydroxy, and imidazole) are identified to guide future experiments. Overall, this work expands our knowledge of small-molecule treatment against COVID-19 and provides a general screening pathway (combining quick ML models with expensive high-fidelity simulations) for targeting several chemical/biochemical problems.

60 APPLIED LIFE SCIENCES↗

Leveraging unlabeled SEM datasets with self-supervised learning for enhanced particle segmentation

Scanning Electron Microscopes (SEMs) are widely used in experimental science laboratories, often requiring cumbersome and repetitive user analysis. Automating SEM image analysis processes is highly desirable to address this challenge. In particle sample analysis, Machine Learning (ML) has emerged as the most effective approach for particle segmentation. However, the time-intensive process of manually annotating thousands of SEM images limits the applicability of supervised learning approaches. Self-Supervised Learning (SSL) offers a promising alternative by enabling knowledge extraction from raw, unlabeled data. This study presents a framework for evaluating SSL techniques in SEM image analysis, focusing on novel methods leveraging the ConvNeXtV2 architecture for particle detection. A dataset comprising 25,000 SEM images is curated to benchmark these proposed SSL methods. The results demonstrate that ConvNeXtV2 models, with varying parameter counts, consistently outperform other techniques in particle detection across different length scales, achieving up to a 34% reduction in relative error compared to established SSL methods. Furthermore, an ablation study explores the relationship between dataset size and SSL performance, providing actionable insights for practitioners regarding model selection and resource efficiency. This research advances the integration of SSL into autonomous analysis pipelines and supports its application in accelerating materials science discovery.

Rettenberger, Luca↗

Materials design, synthesis, and transport properties of disordered rare-earth Zintl bismuthides with the anti -Th 3 P 4 structure type

The synthesis, structural elucidation, and transport properties of the extended series Ca 4–x RE x Bi 3 (RE = Y, La–Nd, Sm, Gd–Tm, and Lu; x ≈ 1) and Ca 4–x RE x Bi 3–δ Sb δ (RE = La, Ho, Er, and Lu; x ≈ 1, δ ≈ 1.5) are presented. Structural elucidation is based on single-crystal X-ray diffraction data and confirms the chemical drive of Ca4Bi3 with the cubic anti-Th 3 P 4 structure type (space group I4 ¯3d, no. 220, Z = 4) into a Zintl phase by the introduction of trivalent rare-earth atoms. The structure features complex bonding, heavy elements, and electron count akin to that of valence-precise semiconductors, making it an ideal target for thermoelectrics development. Introducing crystallographic site disorders at the cation site for the Ca 4–x RE x Bi 3 phase and both the cation and anion sites for the Ca 4–x RE x Bi 3–δ Sb δ phase brings about additional desirable characteristics for thermoelectric materials in the context of tuning knobs for lowering thermal conductivity. Electronic structure calculations of idealized Ca 3 YBi 3 and Ca 3 LaBi 3 compounds indicate the opening of indirect bandgaps at the Fermi level with magnitudes Eg = 0.38 eV and 0.57 eV, respectively. The electrical resistivity ρ(T) of some of the investigated phases measured on single crystals evolve in a metallic manner with magnitudes of order 1.4 mΩ cm near 500 K, thus supporting the notion of a degenerate semiconducting state, with the temperature dependence of the Seebeck coefficient α(T) suggesting the p-type behavior. Furthermore, the low electrical resistivity and the realization of a degenerate semiconducting state in the title phases present a window of opportunity for optimizing their carrier concentrations for enhanced thermoelectric performance.

36 MATERIALS SCIENCE↗

2D-3D registration for prostate radiation therapy based on a statistical model of transmission images

Purpose: In external beam radiation therapy of pelvic sites, patient setup errors can be quantified by registering 2D projection radiographs acquired during treatment to a 3D planning computed tomograph (CT). We present a 2D-3D registration framework based on a statistical model of the intensity values in the two imaging modalities. Methods: The model assumes that intensity values in projection radiographs are independently but not identically distributed due to the nonstationary nature of photon counting noise. Two probability distributions are considered for the intensity values: Poisson and Gaussian. Using maximum likelihood estimation, two similarity measures, maximum likelihood with a Poisson (MLP) and maximum likelihood with Gaussian (MLG), distribution are derived. Further, we investigate the merit of the model-based registration approach for data obtained with current imaging equipment and doses by comparing the performance of the similarity measures derived to that of the Pearson correlation coefficient (ICC) on accurately collected data of an anthropomorphic phantom of the pelvis and on patient data. Results: Registration accuracy was similar for all three similarity measures and surpassed current clinical requirements of 3 mm for pelvic sites. For pose determination experiments with a kilovoltage (kV) cone-beam CT (CBCT) and kV projection radiographs of the phantom in the anterior-posterior (AP) view, registration accuracies were 0.42 mm (MLP), 0.29 mm (MLG), and 0.29 mm (ICC). For kV CBCT and megavoltage (MV) AP portal images of the same phantom, registration accuracies were 1.15 mm (MLP), 0.90 mm (MLG), and 0.69 mm (ICC). Registration of a kV CT and MV AP portal images of a patient was successful in all instances. Conclusions: The results indicate that high registration accuracy is achievable with multiple methods including methods that are based on a statistical model of a 3D CT and 2D projection images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-121: Measuring Prompt Gamma Emission Profiles with a Multi-Stage Compton Camera During Proton Beam Irradiation: Initial Studies

Purpose: Recent studies have suggested that the characteristics of prompt gammas (PG) emitted during proton beam irradiation are advantageous for determining beam range during treatment delivery. The purpose of this work was to determine the feasibility of determining the proton beam range from PG data measured with a prototype Compton camera (CC) during proton beam irradiation. Methods: Using a prototype multi-stage CC the PG emission from a water phantom was measured during irradiation with clinical proton therapy beams. The measured PG emission data was used to reconstruct an image of the PG emission using a backprojection reconstruction algorithm. One dimensional (1D) profiles extracted from the PG images were compared to: 1) PG emission data measured at fixed depths using collimated high purity Germanium and Lanthanum Bromide detectors, and 2) the measured depth dose profiles of the proton beams. Results: Comparisons showed that the PG emission profiles reconstructed from CC measurements agreed very well with the measurements of PG emission as a function of depth made with the collimated detectors. The distal falloff of the measured PG profile was between 1 mm to 4 mm proximal to the distal edge of the Bragg peak for proton beam ranges from 4 cm to 16 cm in water. Doses of at least 5 Gy were needed for the CC to measure sufficient data to image the PG profile and localize the distal PG falloff. Conclusion: Initial tests of a prototype CC for imaging PG emission during proton beam irradiation indicated that measurement and reconstruction of the PG profile was possible. However, due to limitations of the operational parameters (energy range and count rate) of the current CC prototype, doses of greater than a typical treatment dose (∼2 Gy) were needed to measure adequate PG signal to reconstruct viable images. Funding support for this project provided by a grant from DoD.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Platelet cloaking of circulating tumour cells in patients with metastatic prostate cancer: Results from ExPeCT, a randomised controlled trial

Background: Circulating tumour cells (CTCs) represent a morphologically distinct subset of cancer cells, which aid the metastatic spread. The ExPeCT trial aimed to examine the effectiveness of a structured exercise programme in modulating levels of CTCs and platelet cloaking in patients with metastatic prostate cancer. Methods: Participants (n = 61) were randomised into either standard care (control) or exercise arms. Whole blood was collected for all participants at baseline (T0), three months (T3) and six months (T6), and analysed for the presence of CTCs, CTC clusters and platelet cloaking. CTC data was correlated with clinico-pathological information. Results: Changes in CTC number were observed within group over time, however no significant difference in CTC number was observed between groups over time. Platelet cloaking was identified in 29.5% of participants. A positive correlation between CTC number and white cell count (WCC) was observed (p = 0.0001), in addition to a positive relationship between CTC clusters and PSA levels (p = 0.0393). Conclusion: The presence of platelet cloaking has been observed in this patient population for the first time, in addition to a significant correlation between CTC number and WCC. Trial registration: ClincalTrials.gov identifier NCT02453139 .

60 APPLIED LIFE SCIENCES↗

Wind Energy and Wildlife Pre- and Post-Construction Project at Pantex Plant

From 2009-2017, we conducted pre- and post-construction monitoring of wildlife at the Pantex Plant before and after construction of five wind turbines on the plant in 2014-2015. Pre-construction acoustic monitoring for bats was conducted at five sites on Pantex. Acoustic (here after Anabat) files were downloaded 30 times with Anabat files recorded from 6/21/2010 through 1/17/2014. The resulting data include over 3,000,000 files and we hope to analyze them in the future. We were never successful recording acoustic data after 2014 (post-construction). This is despite numerous attempts to trouble shoot our acoustic monitors. Wind damage to cables going from the body of the monitor to their microphones could not be repaired or replaced while towers were standing. Sampling of breeding birds was accomplished through point counts conducted at sites selected for turbine construction and others selected as control sites. Precipitation varied greatly over the course of the study, from a low of 17.81 cm (7.01 inches) during 2011 to a high of 87.96 cm (34.63 inches) during 2015. The pre-construction portion of the project was characterized by fairly extreme drought starting in 2011. Total precipitation for 2011 and 2012 was just 49.12 cm (19.34 inches), less than 50% of the average for a two-year period. The impact of this drought on nesting grassland birds manifest as low nesting species richness and abundance. In 2011 and 2012, 20 and 17 species were documented during point counts, respectively. Post-construction sampling followed the wet year of 2015 (87.96 cm, 34.63 inches). Species richness of nesting birds in 2016 and 2017 was considerably higher than during the drought, 40 and 37 species, respectively. We suspect changes in resource availability associated with relief from drought starting after 2015 was responsible for the recovery/increase in species detected during the breeding season; less importantly any changes from installation of turbines or changes in surface management (e.g., row-crop type).

54 ENVIRONMENTAL SCIENCES↗

Reaction Rate Ratios for Recent Fast Metal Experiments with Large Plutonium Masses

Reaction rate ratios are integral responses that are used within the criticality experiments field because they contain spectral information. While these types of measurements have been utilized for nuclear data validation with historic experiments, few experiments of this type have been utilized for recent experiments, as few exist. This work focuses on measured reaction rate ratios for two nearly bare plutonium critical assemblies with different geometries: one that is cube like (with a Pu mass of 40 kg) and one that is slab like (with a Pu mass of 109 kg). Irradiations were performed with both configurations in which foils were placed near the center of the assembly. Plutonium, highly enriched uranium, depleted uranium, and Au foils were included in the irradiation and counted via high-purity germanium detectors. From these measurements, reaction rate ratios were calculated. Measured and simulated values and uncertainties are presented for the reaction rate ratios. Ratios utilizing the following reactions are given in this work: 197 Au(n, γ), 197 Au(n,2n), 235 U(n,fission), 238 U(n, fission), 238 U(n,2n), 238 U(n,γ), and 239 Pu(n,fission). Uncertainties for the measured reaction rate ratios ranged from 4% to 7%, and the contribution of various parameters to this uncertainty was investigated. The results are compared to historical experiments and should be used for nuclear data validation for future nuclear data library releases. These measurements are part of the EUCLID (Experiments Underpinned by Computational Learning for Improvements in Nuclear Data) project, which utilizes measurement responses in addition to k eff (such as these reaction rate ratios) to help reduce uncertainties in 239 Pu nuclear data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Branches, quivers, and ideals for knot complements

We generalize the F K invariant, i.e. Z^ for the complement of a knot K in the 3-sphere, the knots-quivers correspondence, and A-polynomials of knots, and find several interconnections between them. We associate an F K invariant to any branch of the A-polynomial of K and we work out explicit expressions for several simple knots. We show that these F K invariants can be written in the form of a quiver generating series, in analogy with the knots-quivers correspondence. We discuss various methods to obtain such quiver representations, among others using R-matrices. We generalize the quantum a-deformed A-polynomial to an ideal that contains the recursion relation in the group rank, i.e. in the parameter a, and describe its classical limit in terms of the Coulomb branch of a 3d-5d theory. We also provide t-deformed versions. Furthermore, we study how the quiver formulation for closed 3-manifolds obtained by surgery leads to the superpotential of 3d N = 2 theory T[M 3 ] and to the data of the associated modular tensor category MTC[M 3 ].

97 MATHEMATICS AND COMPUTING↗

Digital pulse processing for NaI(Tl) detectors

We apply two different post-processing techniques to digital pulses induced by photons in a NaI(Tl) detector and compare the obtained energy resolution to the standard analog approach. Our digital acquisition approach is performed using a single-stage acquisition with a fast digitizer. Both the post-processing techniques we propose rely on signal integration. In the first, the pulse integral is calculated by directly numerically integrating the pulse digital samples, while in the second the pulse integral is estimated by a model-based fitting of the pulse. Our study used a 7.62 cm×7.62 cm cylindrical NaI(Tl) detector that gave a 7.60% energy resolution (at 662 keV), using the standard analog acquisition approach, based on a pulse shaping amplifier. The new direct numerical integration yielded a 6.52% energy resolution. The fitting approach yielded a 6.55% energy resolution, and, although computationally heavier than numerical integration, is preferable when only the early samples of the pulse are available. We also evaluated the timing performance of a fast–slow detection system, encompassing an EJ-309 and a NaI(Tl) scintillator. Here, we use two techniques to determine the pulse start time: constant fraction discrimination (CFD) and adaptive noise threshold timing (ANT), for both the analog and digital acquisition approach. With the analog acquisition approach, we found a system time resolution of 5.8 ns and 7.3 ns, using the constant fraction discrimination and adaptive noise threshold timing, respectively. With the digital acquisition approach, a time resolution of 1.2 ns was achieved using the ANT method and 3.3 ns using CFD at 50% of the maximum, to select the pulse start time. Finally, the proposed direct digital readout and post-processing techniques can improve the application of NaI(Tl) detectors, traditionally considered ‘slow’, for fast counting and correlation measurements, while maintaining a good measurement of the energy resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SAIL-Net Raw and Post Corrected POPS Data Fall 2021 - Summer 2023

SAIL-Net is a DOE funded project in the East River Watershed near Crested Butte, Colorado with the goal of advancing our understanding of aerosol-cloud interactions in complex, mountainous regions. Through the deployment of a network of six low cost microphysics nodes in Fall 2021 in the same domain at the SAIL campaign, SAIL-Net provides data on aerosol size distributions, cloud condensation nuclei (CCN), and ice nucleation particles (INP). This network enables the investigation of small-scale variations in complex terrain. Two datasets are provided - one containing raw data and the other containing post-corrected data. The raw dataset provides the raw data recorded from the POPS which were deployed at each of the six sites. These data are organized by site and broken down into daily data files. The six site names used here are: “gothic”, “irwin”, “cbtop”, “cbmid”, “pumphouse”, and “snodgrass”. These data are not cleaned or post-corrected, but some flags have been added. The data are reported at 1 second time resolution. The post-corrected dataset provides the post-corrected and cleaned data recorded from the POPS which were deployed at each of the six sites. This data are also organized by site (same as those found in the raw data) and broken down into daily data files. Unlike the raw POPS data, these data have already been cleaned to remove what we believe are bad values. These data should be ready to use with no cleaning. For a full description of the cleaning and post-correction process, see the readme.

54 ENVIRONMENTAL SCIENCES↗

Effects of Correlated and Uncorrelated Gamma Rays on Neutron Multiplicity Counting

Neutron multiplicity counting relies on time correlation between neutron events to assay the fissile mass, (α,n) to spontaneous fission neutron ratio, and neutron self-multiplication of samples. Gamma-ray sensitive neutron multiplicity counters may misidentify gamma rays as neutrons and therefore miscalculate sample characteristics. Time correlated and uncorrelated gamma-ray-like signals were added into gamma-ray free neutron multiplicity counter data to examine the effects of gamma ray signals being misidentified as neutron signals on assaying sample characteristics. Multiplicity counter measurements with and without gamma-ray-like signals were compared to determine the assay error associated with gamma-ray-like signals at various gamma-ray and neutron rates. Correlated and uncorrelated gamma-ray signals each produced consistent but different measurement errors. Correlated gamma-ray signals most strongly led to fissile mass overestimates, whereas uncorrelated gamma-ray signals most strongly lead to (α,n) neutron overestimates. Gamma-ray sensitive neutron multiplicity counters may be able to account for the effects of gamma-rays on measurements to mitigate measurement uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A technique for synthesizing metal tritide standards

Before surplus plutonium pits can be decommissioned and converted into metal oxides to be used as reactor fuels, residual tritium must be reduced to an acceptable level. We have developed two analytical methods involving melting and acid dissolution, combined with liquid scintillation counting as a quantitative and sensitive technique for measuring residual tritium in Pu metal. The detection limit, linearity, and reproducibility of these analytical methods must be validated with a series of metal tritide standards. Since there are no commercially available metal tritide standards, we have developed a technique for their synthesis. The synthesis of these low-level metal tritide standards is accomplished by charging cerium powder with a known amount of tritium to form a master cerium tritide alloy and then by aliquoting from this master alloy and diluting with pure cerium powder to form a series of standards with different tritium concentrations. The major difficulty in synthesizing these standards is that the samples contain extremely low levels of tritium, which span over three decades of concentrations. The synthesis technique and initial data obtained for cerium hydride samples will be presented. (authors)

36 MATERIALS SCIENCE↗

THE SPITZER DEEP, WIDE-FIELD SURVEY

The Spitzer Deep, Wide-Field Survey (SDWFS) is a four-epoch infrared survey of 10 deg.{sup 2} in the Booetes field of the NOAO Deep Wide-Field Survey using the IRAC instrument on the Spitzer Space Telescope. SDWFS, a Spitzer Cycle 4 Legacy project, occupies a unique position in the area-depth survey space defined by other Spitzer surveys. The four epochs that make up SDWFS permit-for the first time-the selection of infrared-variable and high proper motion objects over a wide field on timescales of years. Because of its large survey volume, SDWFS is sensitive to galaxies out to z {approx} 3 with relatively little impact from cosmic variance for all but the richest systems. The SDWFS data sets will thus be especially useful for characterizing galaxy evolution beyond z {approx} 1.5. This paper explains the SDWFS observing strategy and data processing, presents the SDWFS mosaics and source catalogs, and discusses some early scientific findings. The publicly released, full-depth catalogs contain 6.78, 5.23, 1.20, and 0.96 x 10{sup 5} distinct sources detected to the average 5{sigma}, 4''-diameter, aperture-corrected limits of 19.77, 18.83, 16.50, and 15.82 Vega mag at 3.6, 4.5, 5.8, and 8.0 {mu}m, respectively. The SDWFS number counts and color-color distribution are consistent with other, earlier Spitzer surveys. At the 6 minute integration time of the SDWFS IRAC imaging, >50% of isolated Faint Images of the Radio Sky at Twenty cm radio sources and >80% of on-axis XBooetes sources are detected out to 8.0 {mu}m. Finally, we present the four highest proper motion IRAC-selected sources identified from the multi-epoch imaging, two of which are likely field brown dwarfs of mid-T spectral class.

99 GENERAL AND MISCELLANEOUS↗