Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “count data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Measuring SNM Isotopic Distributions using FRAM

The first group of slides provides background information on the isotopic composition of plutonium. It is shown that 240 Pu is the critical isotope in neutron coincidence/multiplicity counting. Next, response function analysis to determine isotopic composition is discussed. The isotopic composition can be determined by measuring the net peak counts from each isotope and then taking the ratio of the counts for each isotope relative to the total counts for the element. Then FRAM (Fixed energy Response function Analysis with Multiple efficiencies) is explained. FRAM can control data acquisition, automatically analyze newly acquired data, analyze previously acquired data, provide information on the quality of the analysis, and facilitate analysis in unusual situations (non-standard energy calibrations, gamma rays from non-SNM isotopes, poor spectra (within limits)).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Biomarkers of Radiosensitivity in A-Bomb Survivors Pregnant at the Time of Bombings in Hiroshima and Nagasaki

Purpose . There is evidence in the literature of increased maternal radiosensitivity during pregnancy. Materials and Methods . We tested this hypothesis using information from the atomic-bomb survivor cohort, that is, the Adult Health Study database at the Radiation Effects Research Foundation, which contains data from a cohort of women who were pregnant at the time of the bombings of Hiroshima and Nagasaki. Previous evaluation has demonstrated long-term radiation dose-response effects. Results/Conclusions . Data on approximately 250 women were available to assess dose-response rates for serum cholesterol, white blood cell count, erythrocyte sedimentation rate, and serum hemoglobin, and on approximately 85 women for stable chromosome aberrations, glycophorin A locus mutations, and naïve CD4 T-cell counts. Although there is no statistically significant evidence of increased radiosensitivity in pregnant women, the increased slope of the linear trend line in the third trimester with respect to stable chromosome aberrations is suggestive of an increased radiosensitivity.

Miles, Edward F.↗

Energetic electrons in the Jovian magnetosphere

Results are reported for a detailed analysis of Pioneer 10 data on energetic particle species in the magnetodisk region of Jupiter's magnetosphere. It is shown that the observed counting rates in the magnetodisk (beyond 20 Jupiter radii) were caused primarily by electrons with energies exceeding 0.06 MeV. Absolute omnidirectional electron intensities in the magnetodisk are presented for five integral energy ranges, and a model electron differential energy spectrum is found to fit the intensities throughout most of the encounter trajectory. It is suggested that the observed spectral shape results from losses of high-energy electrons by pitch-angle scattering. Observed equatorial energy spectra are used to compute distribution functions for several values of the first adiabatic invariant, mu. The radial profiles of the functions are found to have maxima at about 50 Jupiter radii inbound as well as at about 90 radii outbound and to diminish strongly for lesser radii. The large decreases in density are shown to require strong losses, and resonant electron whistler-mode pitch-angle scattering is suggested as a loss mechanism.

Baker, D. N.↗

An analysis of new techniqes for radiometric correction of LANDSAT-4 Thematic Mapper images

The utility of methods for generating TM RLUTS which can improve the quality of the resultant images was investigated. The TM-CCT-ADDS tape was changed to account for a different collection window for the calibration data. Several scenes of Terrebonne Bay, Louisiana and the Grand Bahamas were analyzed to evaluate the radiometric corrections operationally applied to the image data and to investigate several techniques for reducing striping in the images. Printer plots for the TM shutter data were produced and detector statistics were compiled and plotted. These statistics included various combinations of the average shutter counts for each scan before and after DC restore for forward and reverse scans. Results show that striping is caused by the detectors becoming saturated when they view a bright cloud and depress the DC restore level.

Kogut, J.↗

Calibration of photon counting imaging microchannel plate detectors for EUV astronomy

The calibration of photon counting imaging detectors for satellite based EUV astronomy is a complex process designed to ensure the validity of the data received 'in orbit'. The methods developed to accomplish calibration of microchannel plate detectors for the Extreme Ultraviolet Explorer are described and illustrated. The characterization of these detectors can be subdivided into three categories: stabilization, performance tests, and environmental tests.

Siegmund, O. H. W.↗

Measuring Airflow With Digital Holographic Interferometry

Digital image-processing system assists in analysis of holographic interferometric images of flow about airfoil. Operating semiautomatically, identifies, counts, and labels interference fringes, then processes distances between fringes into distribution of pressure on surface of airfoil. Yields data on pressure faster than manual image-analyses techniques, and data compares favorably with those obtained by manual analysis and by probe measurements of pressure. Uses computer programs evaluating interferograms along straight or curved lines represented by polygon segments. User prompted for such inputs as reference points and fringe number. Digitizes holographic interferograms of flow and processes them into data of pressure or other properties of flow.

Torres, Francisco J.↗

Geologic Evolution of the Martian Highlands: MTMs -20002, -20007, -25002, and -25007

As part of a continuing study to understand the relationship between valleys and highland resurfacing through geologic mapping, the authors are continuing to map seven 1:500,000-scale MTM quads in portions of the Margaritifer, Arabia, and Noachis Terrae. Results from this mapping will also help constrain the role and extent of past water in the region. The MTMs are grouped in two different areas within the region and compliment previous mapping in adjacent areas. Three western quads focus on Jones crater and the Himera, Samara, and Loire Valles systems. This abstract focuses on the four eastern quads wherein a large, ancient impact structure, Noachis basin, is flanked on its south and east by a series of valley networks. A solitary valley drains this basin and stretches north-northeast for approximately 450 km, transporting materials into Arabia Terra. Pertinent raster and vector data have been imported and registered using ESRI's ArcMap GIS software. To inspect and quantify stratigraphic relations, crater counts are being compiled in ESRI's ArcView GIS software to make use of crater counting tools specifically developed for planetary mappers. New datasets from the Mars Reconnaissance Orbiter including 4 CTX images, 31 CRISM multi-spectral pushbroom images, and 4 HiRISE images were incorporated into the project during the third year. The CRISM dataset uses summary parameters with thresholds to select targets for the high-resolution datasets. The befit for mappers is the extensive coverage and general compositional information. Results of a cursory analysis show strong mafic absorptions on the floors of Peta crater and Noachis basin. LCP absorptions occur more often than olivine, however, olivine tends to be denser than both pyroxenes. Olivine and HCP mat indicate relatively younger rocks, which is supported by the occurrence of wrinkle ridges associated with high olivine and HCP absorptions in the Peta crater and Noachis basin floors.

Fortezzo, C. M.↗

A Microbial Analysis of Space-Grown Produce

Before space crops become a permanent staple of the astronaut diet, we must first understand how plants and pathogenic microbes interact in microgravity. Crops such as red romaine lettuce and Chinese cabbage were grown on the International Space Station and sent back to Kennedy Space Center for microbial analysis. Aerobic plate counts and metagenomic sequencing were used to characterize bacterial and fungal communities for plants and their respective ''pillows''. These data will be used to create new guidelines for the microbial safety of space-grown produce, and will help us better protect astronauts from food-borne pathogens like E.coli, Staphylococcus, and Salmonella.

Barash, Eric L.↗

ENSO and MJO Modulation of U.S. Cloud-to-Ground Lightning Activity

Cloud-to-ground (CG) lightning substantially impacts human health and property. However, the relations between U.S. lightning activity and the Madden-Julian Oscillation (MJO) and El Niño-Southern Oscillation (ENSO), two predictable drivers of global climate variability, remain uncertain, in part because most lightning datasets have short records that cannot robustly reveal MJO- and ENSO-related patterns. To overcome this limitation, we developed an empirical model of 6-hourly lightning flash count over the contiguous U.S. (CONUS) using environmental variables (convective available potential energy and precipitation) andNational Lightning Detection Network data for 2003–2016. This model is shown to reproduce the observed daily and seasonal variability of lightning over most of CONUS. Then, the empirical model was applied to construct a proxy lightning dataset for the period 1979–2021, which was used to investigate the summer MJO-lightning relationship at daily resolution and the winter-spring ENSO-lightning relationship at seasonal resolution. Overall, no robust relationship between MJO phase and lightning patterns was found when seasonality was taken into consideration. El Niño is associated with increased lightning activity over the Coastal Southeast U.S. during early winter, the Southwest during winter through spring, and the Northwest during late spring, whereas La Niña is associated with increased lightning activity over the Tennessee River Valley during winter.

Lightning↗

Measurements of Gas Bubble Size Distributions in Flowing Liquid Mercury

ABSTRACT Pressure waves created in liquid mercury pulsed spallation targets have been shown to induce cavitation damage on the target container. One way to mitigate such damage would be to absorb the pressure pulse energy into a dispersed population of small bubbles, however, measuring such a population in mercury is difficult since it is opaque and the mercury is involved in a turbulent flow. Ultrasonic measurements have been attempted on these types of flows, but the flow noise can interfere with the measurement, and the results are unverifiable and often unrealistic. Recently, a flow loop was built and operated at Oak Ridge National Labarotory to assess the capability of various bubbler designs to deliver an adequate population of bubbles to mitigate cavitation damage. The invented diagnostic technique involves flowing the mercury with entrained gas bubbles in a steady state through a horizontal piping section with a glass-window observation port located on the top. The mercury flow is then suddenly stopped and the bubbles are allowed to settle on the glass due to buoyancy. Using a bright-field illumination and a high-speed camera, the arriving bubbles are detected and counted, and then the images can be processed to determine the bubble populations. After using this technique to collect data on each bubbler, bubble size distributions were built for the purpose of quantifying bubbler performance, allowing the selection of the best bubbler options. This paper presents the novel procedure, photographic technique, sample visual results and some example bubble size distributions. The best bubbler options were subsequently used in proton beam irradiation tests performed at the Los Alamos National Laboratory. The cavitation damage results from the irradiated test plates in contact with the mercury are available for correlation with the bubble populations. The most effective mitigating population can now be designed into prototypical geometries for implementation into an actual SNS target.

99 GENERAL AND MISCELLANEOUS↗

Improved Nondestructive Isotopic Analysis with Practical Microcalorimeter Gamma Spectrometers

Advances in both instrumentation and data analysis software are now enabling the first ultra-high-resolution microcalorimeter gamma spectrometers designed for implementation in nuclear facilities and analytical laboratories. With approximately ten times better energy resolution than high-purity germanium detectors, these instruments can overcome important uncertainty limits. Microcalorimeter gamma spectroscopy is intended to provide nondestructive isotopic analysis capabilities with sufficient precision and accuracy to reduce the need for sampling, chemical separations, and mass spectrometry to meet safeguards and security goals. Key milestones were the development of the SOFIA instrument (Spectrometer Optimized for Facility Integrated Applications) and the SAPPY software (Spectral Analysis Program in PYthon). SOFIA is a compact instrument that combines advances in large multiplexed transition-edge sensor arrays with optimized cryogenic performance to overcome many practical limitations of previous systems. With a 256-pixel multiplexed detector array capable of 5,000 counts per second, measurement time can be comparable to high-purity germanium detectors. SAPPY was developed to determine isotopic ratios in data from SOFIA and other microcalorimeter instruments with an approach similar to the widely-used FRAM software. SAPPY provides a flexible framework with rigorous uncertainty analysis for both microcalorimeter and high purity germanium (HPGe) data, allowing direct comparison. Here, we present current results from the SOFIA instrument, preliminary isotopic analysis using SAPPY, and describe how the technology is being used to explore uncertainty limits of nondestructive isotopic characterization, inform safeguards models, and extract improved nuclear data including gamma-ray branching ratios.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SPECTRAL RELATIVE ABSORPTION DIFFERENCE METHOD

When analyzing field data, the uncertainty in the background continuum emission produces the majority of error in the final gamma-source analysis. The background emission typically dominates an observed spectrum in terms of counts and is highly variable spatially and temporally. The majority of the spectral shape of the background continuum is produced by combinations of cosmic rays, {sup 40}K, {sup 235}U, and {sup 220}Rn, and the continuum is similar in shape to the 15%-20% level for most field observations. However, the goal of spectroscopy analysis is to pick up subtle peaks (<%5) upon this large background. Because the continuum is falling off as energy increases, peak detection algorithms must first define the background surrounding the peak. This definition is difficult when the range of background shapes is considered. The full spectral template matching algorithms are heavily weighted to solving for the background continuum as it produces significant counts over much of the energy range. The most appropriate background mitigation technique is to take a separate background observation without the source of interest. But, it is frequently not possible to record a background observation in the exact location before (or after) a source has been detected. Thus, one uses approximate backgrounds that rely on spatially nearby locations or similar environments. Since the error in many field observations is dominated by the background, a technique that is less sensitive to the background would be quite beneficial. We report the result of an initial investigation into a novel observation scheme for gamma-emission detection in high background environments. Employing low resolution, NaI, detectors, we examine the different between the direct emission and the 'spectral-shadow' that the gamma emission produces when passed through a thin absorber. For this detection scheme to be competitive, it is required to count and analyze individual gamma-events. We describe the unique instrumental setup which we assembled to make these measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A High Count Rate Beam Monitor for Thermal Neutrons

Beam monitors are an important diagnostic tool in neutron science facilities. Present beam monitors use either ionization chambers in integration mode, which are slow and have no timing information, or pulse counters which can easily be saturated by high beam intensities. Neutron beam monitors indicate the number of neutrons incident on a scattering sample and allow neutron experimental data to be analyzed even when the source strength varies with time. At high flux neutron scattering facilities, neutron beam monitors with very low efficiency (10-5) are presently selected to keep the counting rate within a feasible range, even when a higher efficiency would improve the counting statistics and yield a better measurement of the incident beam. In this work, we report on a high count rate neutron beam monitor which also offers position sensitivity to provide a beam profile. This beam monitor offers good timing (less than 1 s) in addition to position resolution and will therefore improve the counting statistics at neutron energies up to 10 eV and allow moderator studies. The detector s main characteristics will be presented including its background rate, its count rate capability which is an order of magnitude higher than present counting monitors, and its efficiency for thermal neutrons.

Barnett, Amanda↗

Observation of the Radiation Environment and Solar Energetic Particle Events in Mars Orbit in May 2018- June 2022

Epithermal Neutron Detector (FREND). Here we present results from measurements of the charged particle fluxes, dose rates and estimation of dose equivalent rates at ExoMars TGO Mars science orbit, provided by Liulin-MO from May 2018 to June 2022. The period of measurements covers the declining and minimum phases of the solar activity in 24th solar cycle and the rising phase of the 25th cycle. Compared are the radiation values of the galactic cosmic rays (GCR) obtained during the different phases of the solar activity. The highest values of the dose rate and flux from GCR are registered from March to August 2020. At the minimum of 24th and transition to 25th solar cycle the dose rate from GCR is 15.9 ± 1.6 µGy h−1, particle flux is 3.3 ± 0.17 cm−2 s−1, dose equivalent rate is 72.3 ± 14.4 µSv h−1. Since September 2020 the dose rate and flux of GCR decrease. Particular attention is drawn to the observation of the solar energetic particle (SEP) events in July, September and October 2021, February and March 2022 as well as their effects on the radiation environment on TGO during the corresponding periods. The SEP event during15–19 February 2022 is the most powerful event observed in our data. The SEP dose during this event is 13.8 ± 1.4 mGy (in Si), the SEP dose equivalent is 21.9 ± 4.4 mSv. SEP events recorded in Mars orbit are related to coronal mass ejections (CME) observed by SOHO and STEREO A coronagraphs. Compared are the time profiles of the count rates measured by Liulin-MO, the neutron detectors of FREND and neutron detectors of the High Energy Neutron Detector (HEND) aboard Mars Odyssey during 15–19 February 2022 event. The data obtained is important for the knowledge of the radiation environment around Mars, regarding future manned and robotic flights to the planet. The data for SEP events in Mars orbit during July 2021-March 2022 contribute to the details on the solar activity at a time when Mars is on the opposite side of the Sun from Earth.

Jordanka Semkova↗

MICROCALORIMETER SPECTROSCOPY AT HIGH PULSE RATES: A MULTI-PULSE FITTING TECHNIQUE

Transition Edge Sensor microcalorimeters can measure X-ray and gamma-ray energies with very high energy resolution and high photon-collection efficiency. For this technology to reach its full potential in future X-ray observatories, each sensor must be able to measure hundreds or even thousands of photon energies per second. Current “optimal filtering” approaches to achieve the best possible energy resolution work only for photons that are well isolated in time, a requirement which is in direct conflict with the need for high-rate measurements. We describe a new analysis procedure to allow fitting for the pulse height of all photons even in the presence of heavy pulse pile-up. In the limit of isolated pulses, the technique reduces to standard optimal filtering with long records. We employ reasonable approximations to the noise covariance function in order to render this procedure computationally viable even for very long data records. The technique is employed to analyze X-ray emission spectra at 600 eV and 6 keV at rates up to 250 counts s{sup −1} in microcalorimeters having exponential signal decay times of approximately 1.2 ms.

79 ASTRONOMY AND ASTROPHYSICS↗

AERONET-OC: Strengths and Weaknesses of a Network for the Validation of Satellite Coastal Radiometric Products

The Ocean Color component of the Aerosol Robotic Network (AERONET-OC) has been implemented to support long-term satellite ocean color investigations through cross-site consistent and accurate measurements collected by autonomous radiometer systems deployed on offshore fixed platforms. The ultimate purpose of AERONET-OC is the production of standardized measurements performed at different sites with identical measuring systems and protocols, calibrated using a single reference source and method, and processed with the same code. The AERONET-OC primary data product is the normalized water leaving radiance determined at center-wavelengths of interest for satellite ocean color applications, with an uncertainty lower than 5% in the blue-green spectral regions and higher than 8% in the red. Measurements collected at 6 sites counting the northern Adriatic Sea, the Baltic Proper, the Gulf of Finland, the Persian Gulf, and, the northern and southern margins of the Middle Atlantic Bay, have shown the capability of producing quality assured data over a wide range of bio-optical conditions including Case-2 yellow substance- and sedimentdominated waters. This work briefly introduces network elements like: deployment sites, measurement method, instrument calibration, processing scheme, quality-assurance, uncertainties, data archive and products accessibility. Emphases is given to those elements which underline the network strengths (i.e., mostly standardization of any network element) and its weaknesses (i.e., the use of consolidated, but old-fashioned technology). The work also addresses the application of AERONET-OC data to the validation of primary satellite radiometric products over a variety of complex coastal waters and finally provides elements for the identification of new deployment sites most suitable to support satellite ocean color missions.

Zibordi, Giuseppe↗

DECIPHERING CONTRIBUTIONS TO THE EXTRAGALACTIC GAMMA-RAY BACKGROUND FROM 2 GeV TO 2 TeV

Astrophysical sources outside the Milky Way, such as active galactic nuclei and star-forming galaxies, leave their imprint on the gamma-ray sky as nearly isotropic emission referred to as the extragalactic gamma-ray background (EGB). While the brightest of these sources may be individually resolved, their fainter counterparts contribute diffusely. In this work, we use a recently developed analysis method, called the Non-Poissonian Template Fit, on up to 93 months of publicly available data from the Fermi Large Area Telescope to determine the properties of the point sources (PSs) that comprise the EGB. This analysis takes advantage of photon-count statistics to probe the aggregate properties of these source populations below the sensitivity threshold of published catalogs. We measure the source-count distributions and PS intensities, as a function of energy, from ∼2 GeV to 2 TeV. We find that the EGB is dominated by PSs, likely blazars, in all seven energy sub-bins considered. These results have implications for the interpretation of IceCube’s PeV neutrinos, which may originate from sources that contribute to the non-blazar component of the EGB. Additionally, we comment on implications for future TeV observatories such as the Cherenkov Telescope Array. We provide sky maps showing locations most likely to contain these new sources at both low (≲50 GeV) and high (≳50 GeV) energies for use in future observations and cross-correlation studies.

79 ASTRONOMY AND ASTROPHYSICS↗

Ecological analysis of associations between groundwater quality and hypertension and cardiovascular disease in rural Saskatchewan, Canada using Bayesian hierarchical models and administrative health data

Highlights: • Hardness and magnesium were associated with decreased risk of cardiovascular disease. • Arsenic concentrations were not associated with the risk of cardiovascular disease. • Summarized water health standards were not associated with cardiovascular disease. Associations between groundwater quality and the prevalence of hypertension and ischemic heart disease were investigated in rural areas of the Canadian province of Saskatchewan. The partially ecological study was analyzed using Bayesian hierarchical models to account for spatial variability in risk. Exposure measures and health outcomes were estimated based on previously collected water quality surveillance data from public water supplies and private wells and administrative health data. Water quality exposures for each study region were estimated by applying geostatistical techniques to arsenic concentrations and principal component (PC) scores. The PC scores summarized groups of parameters measuring either health standards or aesthetic objectives described by the province. Generalized linear mixed models with a log link assessed associations between water quality and observed count of health outcomes relative to the expected value. The Bayesian models contained uncorrelated and spatially correlated random effects for each geographic region. Effect estimates were controlled for sex and age by stratification of case and expected case counts, for smoking by inclusion of sex- and age-specific prevalence of chronic obstructive pulmonary disease as a surrogate covariate, and for education and income by use of census data. There was no evidence for associations between groundwater arsenic concentrations in public or private water supplies and increased risk of hypertension or cardiovascular disease. An increase in the second aesthetic objectives PC score from public supplies was associated with a protective effect against ischemic heart disease. This PC value summarized hardness and magnesium Similarly, an increase in the second aesthetic objectives PC in private supplies was associated with decreased prevalence of hypertension. The results of this study are consistent with others demonstrating a relationship between elevated hardness and magnesium concentrations in drinking water and reduced risk of hypertension and cardiovascular disease. Further investigation is warranted with individual exposure history, particularly with respect to the potential beneficial effect of hard water on the prevalence of hypertension and cardiovascular disease.

54 ENVIRONMENTAL SCIENCES↗