Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “corrected data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Towards a more complete description of nucleon distortion in lepton-induced single-pion production at low-$Q^2$

Theoretical predictions for lepton-induced single-pion production (SPP) on $^{12}$C are revisited in order to assess the effect of different treatments of the current operator. On one hand we have the asymptotic approximation, which consists in replacing the particle four-vectors that enter in the operator by their asymptotic values, i.e., their values out of the nucleus. On the other hand we have the full calculation, which is a more accurate approach to the problem. We also compare with results in which the final nucleon is described by a relativistic plane wave, to rate the effect of the nucleon distortion. The study is performed for several lepton kinematics, reproducing inclusive and semi-inclusive cross sections belonging to the low-$Q^2$ region (between 0.05 and 1 GeV$^2$), which is of special interest in charged-current (CC) neutrino-nucleus 1$\pi$ production. Inclusive electron results are compared with experimental data. We find non-trivial corrections comparable in size with the effect of the nucleon distortion, namely, corrections up to 6%, either increasing or diminishing the asymptotic prediction, and a shift of the distributions towards higher energy transfer. For the semi-inclusive cross sections, we observe the correction to be prominent mainly at low values of the outgoing nucleon kinetic energy. Finally, for CC neutrino-induced 1$\pi^+$ production, we find a reduction at low-$Q^2$ with respect to both the plane-wave approach and the asymptotic case.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Validation of Hadron Mass Correction Schemes in Deep Inelastic Scattering at Low Energy Transfer

One method of describing the quark-gluon of the structure proton relies on factorizing its cross-section into a process-dependent short distance element and an independent long distance element that quantifies the quark and gluon momentum distributions within the proton. This research focuses on validating the kinematic range at which factorization theorems still accurately describe the cross-section, in particular for events that simulate scattering on large momentum quarks, that are sensitive to the details of the color mechanism. In this regime, effects which otherwise scale away at large energies, become non-negligible at low energies. The goal of this research is to assess the viability of an extended version of ?collinear factorization? recently proposed by J. Guerrero and A. Accardi, which includes kinematic corrections at quark level, known as ?hadron mass corrections?, to account for the masses of the quarks and the target. To accomplish this, deep inelastic scattering events are simulated using a realistic model of deep inelastic scattering, in which one may analytically calculate both the structure functions and the quark distribution functions. These simulated experiments are then used to test the viability of the proposed factorization theorem by fitting the quark distributions and comparing these to the analytically calculable ones. It is found that the viability of hadron mass corrections in low energy scattering experiments, such as those at Jefferson Lab, extends beyond the kinematic range suggested by analytic calculations alone, provided that residual higher twist corrections are simultaneously fitted to the data.

Krause, Andrew↗

SU-E-T-630: Commissioning for SRS Planning Systems

Purpose: This study will try to find optimal procedures to collect small fields beam data for commissioning in treatment planning systems (TPS), and to provide a protocol to collect output factors for very small field sizes: 0.5 cm × 0.5 cm to 4.0 cm × 4.0 cm.This will help in determining the correct beam configuration methods in TPS planning intensity modulated radiation therapy (IMRT), and stereotactic radiosurgery SRS using mini multileaf collimation (mMLC). Methods: Data has been collected for a mMLC linear accelerator (linac) Novalis from 0.5 cm × 0.5 cm to 10 cm × 10 cm (its maximum field size). The TPS chosen is BrainLab, Eclipse and Cyberknife. The beam data collected was modeled and imported in the TPS. Verification plans were generated in solid water to confirm the goodness of the data. 3D and IMRT plans on regular CT scans were generated and verified using Mapcheck. All 3D plans with field sizes above 4 cm × 4 cm verified excellent using a distance to agreement of 2 mm and a 2% tolerance. IMRT plans gave an error of -8%. New scans with new detectors have been taken, new field sizes were introduced, and focus has been applied on determining the dosimetric leaf gap. Results: Although this is still a work in progress, this study brings several issues to light: the importance of the correct technique in beam data collection from the correct watertank to the correct detectors. Readings for rectangular fields have to be taken especially for fields which one side is under 4 cm. Conclusion: The use of equivalent square fields will not provide correct readings for the fields with large differences between the length and the width.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-I-08: Investigation of Deconvolution Methods for Blocker-Based CBCT Scatter Estimation

Purpose: To investigate whether deconvolution methods can improve the scatter estimation under different blurring and noise conditions for blocker-based scatter correction methods for cone-beam X-ray computed tomography (CBCT). Methods: An “ideal” projection image with scatter was first simulated for blocker-based CBCT data acquisition by assuming no blurring effect and no noise. The ideal image was then convolved with long-tail point spread functions (PSF) with different widths to mimic the blurring effect from the finite focal spot and detector response. Different levels of noise were also added. Three deconvolution Methods: 1) inverse filtering; 2) Wiener; and 3) Richardson-Lucy, were used to recover the scatter signal in the blocked region. The root mean square error (RMSE) of estimated scatter serves as a quantitative measure for the performance of different methods under different blurring and noise conditions. Results: Due to the blurring effect, the scatter signal in the blocked region is contaminated by the primary signal in the unblocked region. The direct use of the signal in the blocked region to estimate scatter (“direct method”) leads to large RMSE values, which increase with the increased width of PSF and increased noise. The inverse filtering is very sensitive to noise and practically useless. The Wiener and Richardson-Lucy deconvolution methods significantly improve scatter estimation compared to the direct method. For a typical medium PSF and medium noise condition, both methods (∼20 RMSE) can achieve 4-fold improvement over the direct method (∼80 RMSE). The Wiener method deals better with large noise and Richardson-Lucy works better on wide PSF. Conclusion: We investigated several deconvolution methods to recover the scatter signal in the blocked region for blocker-based scatter correction for CBCT. Our simulation results demonstrate that Wiener and Richardson-Lucy deconvolution can significantly improve the scatter estimation compared to the direct method.

60 APPLIED LIFE SCIENCES↗

SU-E-J-134: An Augmented-Reality Optical Imaging System for Accurate Breast Positioning During Radiotherapy

Purpose: Breast radiotherapy, particularly electronic compensation, may involve large dose gradients and difficult patient positioning problems. We have developed a simple self-calibrating augmented-reality system, which assists in accurately and reproducibly positioning the patient, by displaying her live image from a single camera superimposed on the correct perspective projection of her 3D CT data. Our method requires only a standard digital camera capable of live-view mode, installed in the treatment suite at an approximately-known orientation and position (rotation R; translation T). Methods: A 10-sphere calibration jig was constructed and CT imaged to provide a 3D model. The (R,T) relating the camera to the CT coordinate system were determined by acquiring a photograph of the jig and optimizing an objective function, which compares the true image points to points calculated with a given candidate R and T geometry. Using this geometric information, 3D CT patient data, viewed from the camera's perspective, is plotted using a Matlab routine. This image data is superimposed onto the real-time patient image, acquired by the camera, and displayed using standard live-view software. This enables the therapists to view both the patient's current and desired positions, and guide the patient into assuming the correct position. The method was evaluated using an in-house developed bolus-like breast phantom, mounted on a supporting platform, which could be tilted at various angles to simulate treatment-like geometries. Results: Our system allowed breast phantom alignment, with an accuracy of about 0.5 cm and 1 ± 0.5 degree. Better resolution could be possible using a camera with higher-zoom capabilities. Conclusion: We have developed an augmented-reality system, which combines a perspective projection of a CT image with a patient's real-time optical image. This system has the potential to improve patient setup accuracy during breast radiotherapy, and could possibly be used for other disease sites as well.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Updated Spin Ephemeris for the Cataclysmic Variable EX Hydrae

Recent satellite observations demonstrate that the phase of maximum flux of the 67 min spin modulation of the white dwarf in the cataclysmic variable EX Hya is drifting away from the optical quadratic ephemeris of Hellier & Sproats (1992, hereafter HS92). Relative to that ephemeris, the peak of the spin-phase extreme ultraviolet (EUV) flux modulation measured with the Extreme Ultraviolet Explorer (EUVE) was {phi}{sub 67} = 0.040 {+-} 0.002 in 1994 May (Mauche 1999) and {phi}{sub 67} = 0.115 {+-} 0.001 in 2000 May (Belle et al. 2002). Similarly, the peak of the spin-phase X-ray flux modulation measured with the Chandra X-ray Observatory was {phi}{sub 67} {approx} 0.1 in 2000 May (Hoogerwerf, Brickhouse, & Mauche 2004) and {phi}{sub 67} {approx} 0.2 in 2007 May (Luna, Brickhouse, & Mauche 2008). Because the discrepancy between the observed O and calculated C phases of the spin-phase flux modulation of EX Hya is now approaching a significant fraction of a spin cycle, we have undertaken the task of updating the ephemeris. Toward that end, we have combined the optical data of Vogt, Krzeminski, & Sterken (1980, hereafter VKS80), Gilliland (1982), Sterken et al. (1983), Hill & Watson (1984), Jablonski & Busko (1985), Bond & Freeth (1988), HS92, Walker & Allen (2000), and Belle et al. (2005) with the optical, EUV, and X-ray data listed in Table 1. The optical data were obtained by CS at ESO La Silla using the Danish 1.5-m telescope and the DFOSC CCD camera. Differential V-band magnitudes were obtained by aperture photometry extracted from flat-fielded and bias-corrected CCD frames. Other than the EXOSAT and Ginga data, which have been taken from the given references, all other times of spin maximum in the table have been derived by us from the various datasets. In the processes, we have corrected an error in the (spin and orbit) phases of the ASCA data published by Ishida, Mukai, & Osborne (1994) and the RXTE data published by Mukai et al. (1998). We note that our result for the second EUVE observation agrees within the errors with the result derived independently by Belle et al. (2002). Table 1 lists the observed times of spin maximum in Barycentric Julian Date, the corresponding cycle number derived from the HS92 quadratic ephemeris, and the O-C residuals relative to the VKS80 linear ephemeris, the HS92 quadratic ephemeris, and our cubic ephemeris (eqn. 1).

99 GENERAL AND MISCELLANEOUS↗

Using spatial statistical methods to determine an effective minimum detectable activity - 15681

Instrument minimum detectable activity (MDA) is generally established by collecting multiple measurements over time of a single representative background location to estimate a probability distribution of instrument readings. A reading that is considered to be greater than would be expected from the background probability distribution (i.e., a low-probability event) is deemed to be sufficiently unlikely that it must be attributable to added radioactivity and is therefore used as the instrument MDA. An effective MDA can be determined from spatially distributed data that are much lower than the instrument MDA. This has been accomplished using a large number of spatially distributed data points (from a radiation survey) where patterns of elevated survey readings can be distinguished from background at levels. Given the variation of the instrument response and the relatively low regulatory action levels, it is vital to establish MDA thresholds that are well below corrective action levels. Processing of radiological survey data with the use of histogram binning and geo-statistics in enabling pattern recognition can be used to establish effective field MDAs that are much lower than instrument MDAs. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ZTF-SEDm Type Ia supernova sample for Twins Embedding spectrophotometric standardization

Aims. This paper has two aims: the first aim is to build a large homogeneous spectrophotometric sample of Type Ia supernovae (SNe Ia) from the second data release of the Zwicky Transient Facility (ZTF DR2). We used the spectrum sample from the low-resolution ( R ∼ 100) SEDmachine (SEDm) Integral Field Spectrograph (IFS) that gathered 3069 spectra. This is one of the largest samples of such collections that can attempt to reproduce the Twins Embedding (TE) spectrophotometric standardization method. This is our second objective. The method was developed based on high-quality spectra from 200 SNe Ia of the Nearby Supernova factory (SNfactory) and led to an exceptionally low value of 0.073 mag for the intrinsic scatter. Methods. As the SEDm is not designed as a spectrophotometric instrument, we first improved the flux-calibration accuracy of the SN Ia spectrum sample using the ZTF photometric data, which were calibrated at the percent level. We corrected the spectra for second-order polynomials, fitted by comparing the synthetic photometry in the ZTF g , r , i filters with the light-curve (LC) data. We then applied the three steps of the TE parameterization to a subset of 783 ZTF SN spectra near maximum light while comparing results from SNfactory and ZTF. We finally analyzed the standardization methods based on the TE parameters. Results. The precision of the phase-correction model, which is the first step of the TE, is estimated at 0.01 mag in g band based on ZTF data. Despite the challenge posed by the spectrum-extraction pipeline associated with the SEDm (flux calibration, leftover host signal, low signal-to-noise ratio, and low resolution), we applied a first standardization in color based on the second step of the TE, called read between the lines (RBTL), to the ZTF sample. We reached a Hubble residual scatter of 0.153 mag, all in normalized median absolute deviation, which is to be compared to the ∼0.11 mag obtained with the SNfactory data. The SALT color and stretch standardization reaches a scatter of 0.164 mag for the same ZTF SN Ia sample, and its host steps are ∼0.1 mag and zero for RBTL. When considering the scatter due to the redshift error and flux calibration error, we estimated a RBTL scatter of ∼0.129 mag for this ZTF sample as an upper limit because we identified an additional contribution from a systematic error in color. We tested the standardization based on the nonlinear TE parameters, and, as expected from the low spectrum quality, it did not improve the overall dispersion. Conclusions. We release 1897 flux calibrated spectra of 1607 SNe Ia with an estimated photometric accuracy of 0.07 mag. We further demonstrate that some amount of spectrophotometric SN Ia standardization can be done with limited-quality spectra. The RBTL standardization is more efficient than that of SALT with one parameter less, and the resulting host steps are consistent with zero. This makes it less prone to astrophysical bias. For future spectroscopic surveys, targeting the extraction pipeline for a thorough flux calibration and good signal-to-noise ratio would enable us to compute the full TE standardization, which would further reduce the scatter in the distance estimate.

Ganot, C↗

Measurements of fuel and ablator ρR in Symmetry-Capsule implosions with the Magnetic Recoil neutron Spectrometer (MRS) on the National Ignition Facility

The Magnetic Recoil neutron Spectrometer (MRS) on the National Ignition Facility (NIF) measures the neutron spectrum in the energy range of 4–20 MeV. This paper describes MRS measurements of DT-fuel and CH-ablator ρR in DT gas-filled symmetry-capsule implosions at the NIF. DT-fuel ρR's of 80–140 mg/cm{sup 2} and CH-ablator ρR's of 400–680 mg/cm{sup 2} are inferred from MRS data. The measurements were facilitated by an improved correction of neutron-induced background in the low-energy part of the MRS spectrum. This work demonstrates the accurate utilization of the complete MRS-measured neutron spectrum for diagnosing NIF DT implosions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A MULTI-WAVELENGTH VIEW OF THE STAR FORMATION ACTIVITY AT z {approx} 3

We present a multi-wavelength, UV-to-radio analysis for a sample of massive (M{sub *} {approx} 10{sup 10} M{sub sun}) IRAC- and MIPS 24 {mu}m detected Lyman break galaxies (LBGs) with spectroscopic redshifts z {approx} 3 in the GOODS-North field. For LBGs without individual 24 {mu}m detections, we employ stacking techniques at 24 {mu}m, 1.1 mm, and 1.4 GHz to construct the average UV-to-radio spectral energy distribution and find it to be consistent with that of a luminous infrared galaxy with L{sub IR} = 4.5{sup +1.1}{sub -2.3} x 10{sup 11} L{sub sun} and a specific star formation rate of 4.3 Gyr{sup -1} that corresponds to a mass doubling time {approx}230 Myr. On the other hand, when considering the 24 {mu}m detected LBGs we find among them galaxies with L{sub IR}>10{sup 12} L{sub sun}, indicating that the space density of z {approx} 3 UV-selected ultra-luminous infrared galaxies (ULIRGs) is {approx}(1.5 {+-} 0.5) x 10{sup -5} Mpc{sup -3}. We compare measurements of star formation rates from data at different wavelengths and find that there is tight correlation (Kendall's {tau}>99.7%) and excellent agreement between the values derived from dust-corrected UV, mid-IR, millimeter, and radio data for the whole range of L{sub IR} up to L{sub IR} {approx} 10{sup 13} L{sub sun}. This range is greater than that for which the correlation is known to hold at z {approx} 2, possibly due to the lack of significant contribution from polycyclic aromatic hydrocarbons to the 24 {mu}m flux at z {approx} 3. The fact that this agreement is observed for galaxies with L{sub IR}>10{sup 12} L{sub sun} suggests that star formation in UV-selected ULIRGs, as well as the bulk of star formation activity at this redshift, is not embedded in optically thick regions as seen in local ULIRGs and submillimeter-selected galaxies at z = 2.

79 ASTRONOMY AND ASTROPHYSICS↗

gcxgclab: Two Dimensional Gas Chromatography Preprocessing and Analysis

The goal of gcxgclab is to provide a comprehensive program for preprocessing and analysis of two dimensional gas chromatography data. It is equipped with functions for baseline correction, smoothing, peak identification, peak alignment, identification of EICs, Mass Spectra, targeted analysis, compound identification with NIST and non-targeted analysis, plus plotting and data visualization.

GAMBLE, STEPHANIE↗

Validating plastic scintillation detectors for photon dosimetry in the radiologic energy range

Purpose: Photon dosimetry in the kilovolt (kV) energy range represents a major challenge for diagnostic and interventional radiology and superficial therapy. Plastic scintillation detectors (PSDs) are potentially good candidates for this task. This study proposes a simple way to obtain accurate correction factors to compensate for the response of PSDs to photon energies between 80 and 150 kVp. The performance of PSDs is also investigated to determine their potential usefulness in the diagnostic energy range. Methods: A 1-mm-diameter, 10-mm-long PSD was irradiated by a Therapax SXT 150 unit using five different beam qualities made of tube potentials ranging from 80 to 150 kVp and filtration thickness ranging from 0.8 to 0.2 mmAl + 1.0 mmCu. The light emitted by the detector was collected using an 8-m-long optical fiber and a polychromatic photodiode, which converted the scintillation photons to an electrical current. The PSD response was compared with the reference free air dose rate measured with a calibrated Farmer NE2571 ionization chamber. PSD measurements were corrected using spectra-weighted corrections, accounting for mass energy-absorption coefficient differences between the sensitive volumes of the ionization chamber and the PSD, as suggested by large cavity theory (LCT). Beam spectra were obtained from x-ray simulation software and validated experimentally using a CdTe spectrometer. Correction factors were also obtained using Monte Carlo (MC) simulations. Percent depth dose (PDD) measurements were compensated for beam hardening using the LCT correction method. These PDD measurements were compared with uncorrected PSD data, PDD measurements obtained using Gafchromic films, Monte Carlo simulations, and previous data. Results: For each beam quality used, the authors observed an increase of the energy response with effective energy when no correction was applied to the PSD response. Using the LCT correction, the PSD response was almost energy independent, with a residual 2.1% coefficient of variation (COV) over the 80-150-kVp energy range. Monte Carlo corrections reduced the COV to 1.4% over this energy range. All PDD measurements were in good agreement with one another except for the uncorrected PSD data, in which an over-response was observed with depth (13% at 10 cm with a 100 kVp beam), showing that beam hardening had a non-negligible effect on the PSD response. A correction based on LCT compensated very well for this effect, reducing the over-response to 3%.Conclusion: In the diagnostic energy range, PSDs show high-energy dependence, which can be corrected using spectra-weighted mass energy-absorption coefficients, showing no considerable sign of quenching between these energies. Correction factors obtained by Monte Carlo simulations confirm that the approximations made by LCT corrections are valid. Thus, PSDs could be useful for real-time dosimetry in radiology applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-186: Cloud-Based Quality Assurance Application for Linear Accelerator Commissioning

Purpose: To identify anomalies and safety issues during data collection and modeling for treatment planning systems Methods: A cloud-based quality assurance system (AQUIRE - Automated QUalIty REassurance) has been developed to allow the uploading and analysis of beam data aquired during the treatment planning system commissioning process. In addition to comparing and aggregating measured data, tools have also been developed to extract dose from the treatment planning system for end-to-end testing. A gamma index is perfomed on the data to give a dose difference and distance-to-agreement for validation that a beam model is generating plans consistent with the beam data collection. Results: Over 20 linear accelerators have been commissioning using this platform, and a variety of errors and potential saftey issues have been caught through the validation process. For example, the gamma index of 2% dose, 2mm DTA is quite sufficient to see curves not corrected for effective point of measurement. Also, data imported into the database is analyzed against an aggregate of similar linear accelerators to show data points that are outliers. The resulting curves in the database exhibit a very small standard deviation and imply that a preconfigured beam model based on aggregated linear accelerators will be sufficient in most cases. Conclusion: With the use of this new platform for beam data commissioning, errors in beam data collection and treatment planning system modeling are greatly reduced. With the reduction in errors during acquisition, the resulting beam models are quite similar, suggesting that a common beam model may be possible in the future. Development is ongoing to create routine quality assurance tools to compare back to the beam data acquired during commissioning. I am a medical physicist for Alzyen Medical Physics, and perform commissioning services.

60 APPLIED LIFE SCIENCES↗

PolyCheck: Dynamic Verification of Iteration Space Transformations on Affine Programs

High-level compiler transformations, especially loop transformations, are widely recognized as critical optimizations to restructure programs to improve data locality and expose parallelism. Guaranteeing the correctness of program transformations is essential, and to date three main approaches have been developed: proof of equivalence of affine programs, matching the execution traces of programs, and checking bit-by-bit equivalence of the outputs of the programs. Each technique suffers from limitations in either the kind of transformations supported, space complexity, or the sensitivity to the testing dataset. In this paper, we take a novel approach addressing all three limitations to provide an automatic bug checker to verify any iteration reordering transformations on affine programs, including non-affine transformations, with space consumption proportional to the original program data, and robust to arbitrary datasets of a given size. We achieve this by exploiting the structure of affine program control- and data-flow to generate at compile-time lightweight checker code to be executed within the transformed program. Experimental results assess the correctness and effectiveness of our method, and its increased coverage over previous approaches.

affine programs↗

A Correction for IUE UV Flux Distributions from Comparisons with CALSPEC

A collection of spectral energy distributions (SEDs) is available in the Hubble Space Telescope (HST) CALSPEC database that is based on calculated model atmospheres for pure hydrogen white dwarfs (WDs). A much larger set (∼100,000) of UV SEDs covering the range (1150–3350 Å) with somewhat lower quality are available in the IUE database. IUE low-dispersion flux distributions are compared with CALSPEC to provide a correction that places IUE fluxes on the CALSPEC scale. While IUE observations are repeatable to only 4%–10% in regions of good sensitivity, the average flux corrections have a precision of 2%–3%. Our re-calibration places the IUE flux scale on the current UV reference standard and is relevant for any project based on IUE archival data, including our planned comparison of GALEX to the corrected IUE fluxes. IUE SEDs may be used to plan observations and cross-calibrate data from future missions, so the IUE flux calibration must be consistent with HST instrumental calibrations to the best possible precision.

79 ASTRONOMY AND ASTROPHYSICS↗

VirION2: a short- and long-read sequencing and informatics workflow to study the genomic diversity of viruses in nature

Microbes play fundamental roles in shaping natural ecosystem properties and functions, but do so under constraints imposed by their viral predators. However, studying viruses in nature can be challenging due to low biomass and the lack of universal gene markers. Though metagenomic short-read sequencing has greatly improved our virus ecology toolkit—and revealed many critical ecosystem roles for viruses—microdiverse populations and fine-scale genomic traits are missed. Some of these microdiverse populations are abundant and the missed regions may be of interest for identifying selection pressures that underpin evolutionary constraints associated with hosts and environments. Though long-read sequencing promises complete virus genomes on single reads, it currently suffers from high DNA requirements and sequencing errors that limit accurate gene prediction. Here we introduce VirION2, an integrated short- and long-read metagenomic wet-lab and informatics pipeline that updates our previous method (VirION) to further enhance the utility of long-read viral metagenomics. Using a viral mock community, we first optimized laboratory protocols (polymerase choice, DNA shearing size, PCR cycling) to enable 76% longer reads (now median length of 6,965 bp) from 100-fold less input DNA (now 1 nanogram). Using a virome from a natural seawater sample, we compared viromes generated with VirION2 against other library preparation options (unamplified, original VirION, and short-read), and optimized downstream informatics for improved long-read error correction and assembly. VirION2 assemblies combined with short-read based data (‘enhanced’ viromes), provided significant improvements over VirION libraries in the recovery of longer and more complete viral genomes, and our optimized error-correction strategy using long- and short-read data achieved 99.97% accuracy. In the seawater virome, VirION2 assemblies captured 5,161 viral populations (including all of the virus populations observed in the other assemblies), 30% of which were uniquely assembled through inclusion of long-reads, and 22% of the top 10% most abundant virus populations derived from assembly of long-reads. Viral populations unique to VirION2 assemblies had significantly higher microdiversity means, which may explain why short-read virome approaches failed to capture them. These findings suggest the VirION2 sample prep and workflow can help researchers better investigate the virosphere, even from challenging low-biomass samples. Our new protocols are available to the research community on protocols.io as a ‘living document’ to facilitate dissemination of updates to keep pace with the rapid evolution of long-read sequencing technology.

Long-reads↗

Two-body potential model based on cosine series expansion for ionic materials

There is a method to construct a two-body potential model for ionic materials with a Fourier series basis and we examine it. For this method, the coefficients of cosine basis functions are uniquely determined by solving simultaneous linear equations to minimize the sum of weighted mean square errors in energy, force and stress, where first-principles calculation results are used as the reference data. As a validation test of the method, potential models for magnesium oxide are constructed. The mean square errors appropriately converge with respect to the truncation of the cosine series. This result mathematically indicates that the constructed potential model is sufficiently close to the one that is achieved with the non-truncated Fourier series and demonstrates that this potential virtually provides minimum error from the reference data within the two-body representation. The constructed potential models work appropriately in both molecular statics and dynamics simulations, especially if a two-step correction to revise errors expected in the reference data is performed, and the models clearly outperform two existing Buckingham potential models that were tested. Moreover, the good agreement over a broad range of energies and forces with first-principles calculations should enable the prediction of materials behavior away from equilibrium conditions, such as a system under irradiation.

36 MATERIALS SCIENCE↗

Peer Review of "Analysis and Simulation of Near-Field Wave Motion Data from the Source Physics Experiment Explosions," Antoun, et al, 2011 Monitoring Research Review

The following is primarily a review of 'Analysis and Simulation of Near-Field Wave Motion Data from the Source Physics Experiment Explosions,' Antoun, et al, published by Lawrence Livermore National Laboratory (LLNL) after SPE-1 in 2011 (Ref. 1). However, LLNL analysis of SPE-2 (Ref. 2) will also be discussed. A review by Los Alamos National Laboratory (LANL) personnel of Reference 1 finds both the evidence of the effects of joints on the data and the correlation of calculations with the data weak. This conclusion is made on three separate levels: (1) Fundamental observations made of the various referenced figures taken as presented; (2) Observations made following corrections to errors and omissions to the selected data; and (3) Observations made after considering likely errors in the raw data set. The evidence presented in the referenced papers relies on subjective interpretation of various figures. This is the nature of this technical field of study and, indeed, much of our observation is also subjective.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗