Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cell parameters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

The power of sensitivity analysis and thoughts on models with large numbers of parameters

The regulatory systems that allow cells to adapt to their environments are exceedingly complex, and although we know a great deal about the intricate mechanistic details of many of these systems, our ability to make accurate predictions about their system-level behaviors is severely limited. We would like to make such predictions for a number of reasons. How can we reverse dysfunctional molecular changes of these systems that cause disease? More generally, how can we harness and direct cellular activities for beneficial purposes? Our ability to make accurate predictions about a system is also a measure ofour fundamental understanding of that system. As evidenced by our mastery of technological systems, a useful understanding ofa complex system can often be obtained through the development and analysis ofa mathematical model, but predictive modeling of cellular regulatory systems, which necessarily relies on quantitative experimentation, is still in its infancy. There is much that we need to learn before modeling for practical applications becomes routine. In particular, we need to address a number of issues surrounding the large number of parameters that are typically found in a model for a cellular regulatory system.

59 BASIC BIOLOGICAL SCIENCES↗

Physical Models from Physical Templates Using Biocompatible Liquid Crystal Elastomers as Morphologically Programmable Inks For 3D Printing

Advanced manufacturing has received considerable attention as a tool for the fabrication of cell scaffolds however, finding ideal biocompatible and biodegradable materials that fit the correct parameters for 3D printing and guide cells to align remain a challenge. Herein, a photocrosslinkable smectic-A (Sm-A) liquid crystal elastomer (LCE) designed for 3D printing is presented, that promotes cell proliferation but most importantly induces cell anisotropy. The LCE-based bio-ink allows the 3D duplication of a highly complex brain structure generated from an animal model. Vascular tissue models are generated from fluorescently stained mouse tissue spatially imaged using confocal microscopy and subsequently processed to create a digital 3D model suitable for printing. The 3D structure is reproduced using a Digital Light Processing (DLP) stereolithography (SLA) desktop 3D printer. Synchrotron Small-Angle X-ray Diffraction (SAXD) data reveal a strong alignment of the LCE layering within the struts of the printed 3D scaffold. The resultant anisotropy of the LCE struts is then shown to direct cell growth. This study offers a simple approach to produce model tissues built within hours that promote cellular alignment.

3D cell culture↗

Development of Clay Thin Plate as First Preparation for Solid Oxide Fuel Cell Manufacture—Preliminary Study

Various methods have heen implemented to manufacture the intermediate temperature solid oxide fuel cell. The quality of thin plate fuel cell that allows the optimum electrons flow within the fuel cell membrane is of interest. This paper investigates the manufacturing process of clay thin plate for solid oxide fuel cell (SOFC) using the compaction method. Several parameter processes that affect the quality of thin plate such as compaction loading, microstructure and deformation of thin plate at green density and after sintering are investigated. The thin plate is fabricated from clay powder using a single acting compaction at a finite loading, for sintering temperature at about 1350° C with holding time of 30 minutes. The thin plate is underwent a scanning process using a Scanning Electron Microscopy to evaluate the grain size and thickness plate. The result indicates the substantial information of parameter process of clay thin plate for solid oxide fuel cell manufacture.

36 MATERIALS SCIENCE↗

Laser-to-proton conversion efficiency studies for proton fast ignition

We assess the conversion efficiency from intense picosecond laser pulses to multi-MeV ion beams for a wide range of laser and target parameters, using 2D kinetic particle-in-cell simulations. Scalings are addressed in a quasi-one-dimensional geometry, leaving out beam divergence. Then, we study the conversion efficiency into a narrow spatial band along the laser axis for flat and hemispherical targets in large-scale 2D simulations. Combining these findings allows us to calculate the energy requirements for ignition of a compressed ICF target with an intense proton beam in a fast-ignition scenario.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimization of plasma amplifiers

Here, plasma amplifiers offer a route to side-step limitations on chirped pulse amplification and generate laser pulses at the power frontier. They compress long pulses by transferring energy to a shorter pulse via the Raman or Brillouin instabilities. We present an extensive kinetic numerical study of the three-dimensional parameter space for the Raman case. Further particle-in-cell simulations find the optimal seed pulse parameters for experimentally relevant constraints. The high-efficiency self-similar behavior is observed only for seeds shorter than the linear Raman growth time. A test case similar to an upcoming experiment at the Laboratory for Laser Energetics is found to maintain good transverse coherence and high-energy efficiency. Effective compression of a 10kJ, nanosecond-long driver pulse is also demonstrated in a 15-cm-long amplifier.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

US terrestrial solar cell calibration and measurement procedures

A workshop was held in the fall of 1976, to evaluate and revise interim terrestrial solar cell calibration and measurement procedures. The revisions made to the interim testing procedures are described. The calibration of reference cells and the design of their holders are covered. Considerations include view angle and optical and thermal matching. Atmospheric factors which affect the calibration and performance of solar cells are discussed. The most critical atmospheric parameter appears to be water vapor. Techniques for matching reference cells to cells or arrays under test are described. Data showing errors in performance under artificial sunlight simulators due to mismatch of reference and test cells are presented. Finally, measurement procedures and data transformations needed to obtain the performance of solar cells and arrays in outdoor natural sunlight are described.

Brandhorst, H. W., Jr.↗

Proton Exchange Membrane (PEM) Fuel Cells for Space Applications

This presentation will provide a summary of the PEM fuel cell development at the National Aeronautics and Space Administration, Johnson Space Center (NASA, JSC) in support of future space applications. Fuel cells have been used for space power generation due to their high energy storage density for multi-day missions. The Shuttle currently utilizes the alkaline fuel cell technology, which has highly safe and reliable performance. However, the alkaline technology has a limited life due to the corrosion inherent to the alkaline technology. PEM fuel cells are under development by industry for transportation, residential and commercial stationary power applications. NASA is trying to incorporate some of this stack technology development in the PEM fuel cells for space. NASA has some unique design and performance parameters which make developing a PEM fuel cell system more challenging. Space fuel cell applications utilize oxygen, rather than air, which yields better performance but increases the hazard level. To reduce the quantity of reactants that need to be flown in space, NASA also utilizes water separation and reactant recirculation. Due to the hazards of utilizing active components for recirculation and water separation, NASA is trying to develop passive recirculation and water separation methods. However, the ability to develop recirculation components and water separators that are gravity-independent and successfully operate over the full range of power levels is one of the greatest challenges to developing a safe and reliable PEM fuel cell system. PEM stack, accessory component, and system tests that have been performed for space power applications will be discussed.

Bradley, Karla↗

Unstructured Grid Development for the Space Launch System Liftoff and Transition Lineloads Computational Analysis

Production of aerodynamic lineloads databases for the Space Launch System (SLS) vehicle at Liftoff and Transition (LOT) conditions has required the development of a Computational Fluid Dynamics (CFD) workflow capable of producing high-quality solutions for this unique phase of flight. Aerodynamic considerations included a wide range of flow angles (from 0°up to 90°total angle of attack), resulting leeside separation, and interaction effects between the three bodies of the integrated SLS vehicle, as well as the nearby launch tower. Computational mesh development for similar problems at the NASA Langley Research Center (such as for the Constellation/Ares launch vehicles) has primarily relied on in-house tools such as VGRID/POSTGRID, with grids designed for NASA-developed and maintained flow solvers such as USM3D and FUN3D. The workflow for such problems has evolved over the development of the various SLS configurations to incorporate new tools such as the Heldenpatch/Heldenmesh grid generator (Helden Aerospace) and CREATE-AV Kestrel (US Department of Defense) flow solver. This paper describes efforts to benchmark a grid generation approach for LOT problems using Heldenpatch/Heldenmesh and Kestrel, verified against prior best practices from VGRID/POSTGRID. Parameters studied include surface grid density, first-layer viscous cell height, and volume grid growth rate parameters. Resulting solutions are compared based on total force and moment values, sectional line loads, and surface pressures, all validated against existing wind tunnel aerodynamic databases where available for the SLS Block 1B Cargo configuration.

Space launch systems↗

Growth Curve Parameterization of Metabolic Activity of Yeast Cells for BioSentinel

The goal of the BioSentinel small satellite payload is to measure the effect of deep space radiation on the growth and metabolic activity of yeast cells. Raw test data is generated by fluidics cards containing yeast cells rehydrated at different periods, with metabolic activity measured by the reduction of alamarBlue. Each card well has a sensor array that measures the amount of red, green, and infrared light transmitted through the yeast culture. This illumination data is then converted to absorbance values, which are further converted into concentrations. The ultimate objective is to convert these concentrations into biologically-relevant metrics that can be compared against one another to determine changes due to differential radiation exposure. Beginning with IR absorbance data (corresponding to cell density) from ground studies, three parameters from a sigmoidal growth curve were extracted and analyzed: 𝜆 (lag phase), 𝜇 (max growth rate), and A (max cell growth). The data was fit to the Gompertz model of microbial growth using non-linear regression (Minitab), as the fit error was reduced compared to the simpler logistic growth curve. Graphs showed that the data contained a discrepancy (drift) in the lag phase that is attributable to a slow, constant loss of moisture. Correcting this discrepancy by fitting the first 25 hours of the data to a power function and subtracting these values from the absorbance readings obtained a better statistical fit to the growth curve in the lag phase. A power fit was selected over a linear fit because it reflected the effects of constant volume loss. This correction to the BioSentinel data analysis pipeline will enable quantitative statistical analysis of the effect of different levels of deep space radiation on yeast cells. Future work includes automation of drift correction and curve modeling to extract these parameters directly from data.

Growth Curve↗

Energy in a Planetary Context

The potential present day habitability of solar system bodies beyond Earth is limited to subsurface environments, where the availability of energy in biologically useful form is a paramount consideration. Energy availability is commonly quantified in terms of molar Gibbs energy changes for metabolisms of interest, but this can provide an incomplete and even misleading picture. A second aspect of life's requirement for energy - the rate of delivery, or power - strongly influences habitability, biomass abundance, growth rates, and, ultimately, rates of evolution. We are developing an approach to quantify metabolic power, using a cell-scale reactive transport model in which physical and chemical environmental parameters are varied. Simultaneously, we evaluate cell-specific energy flux requirements and their dependence on environmental "extremes". Comparison of metabolic power supply and demand provides a constraint on how biomass abundance varies across a range of environmental parameters, and thereby a prediction of the relative habitability of different environments. We are evaluating the predictive capability of this approach through comparison to observed distributions of microbial abundance in a range of subsurface (predominantly serpentinizing) systems.

MARINE GEOMICROBIOLOGY↗

A Novel Lithium-ion Laminated Pouch Cell Tested For Performance And Safety

A new Li-ion 4.0 Ah pouch cell from GS Yuasa has been tested to determine its performance and safety. The cell is of a laminate pouch design with liquid electrolyte. The rate, thermal and vacuum performance capabilities have been tested to determine the optimum parameters. Under vacuum conditions, the cells were cycled under restrained and unrestrained configurations. The burst pressure of the laminate pouch was also determined. The overcharge, overdischarge into reversal and external short circuit safety tests were also performed to determine the cell s tolerance to abuse. Key Words: Li-ion, safety, vacuum test, abuse, COTS batteries, rate capability

Jeevarajan, Judith A.↗

Wastewater Brine Purification and Recovery through Electrodialysis Ion Exchange

Reutilizing resources onboard the International Space Station (ISS) and for future deep space missions are critical for mission longevity and sustainability. Wastewater brine produced from water recovery systems contain chemical species that could be processed into a potential fertilizer for future plant systems. This can be achieved through a process called electrodialysis ion exchange. Wastewater containing inorganic salt components are fed through a series of ion exchange membranes to produce fertilizer (a phosphate rich stream), electrolysis-grade water, and other useful commodities. Electrodialysis cells consisting of anion and cation exchange membranes, monovalent anion exchange membranes, and bipolar membranes were utilized to achieve selective ion exchange. The use of the electrodialysis cells were effective for both water extraction and ion separation. Ions successfully diffused across their respective membranes into the concentrate, acid, and base streams. This resulted in pure water, a phosphate rich stream, and a separate anion/hydrogen and cation/hydroxide stream. However, sulfate and some phosphate ions were able to diffuse through the monovalent anion exchange membrane into the acid stream. This resulted in predominantly phosphate ions remaining in the concentrate. Optimization of the process was accomplished by altering flowrates of each stream and initial volumes, adjusting the power input and resulting current through each cell, and varying the starting parameters by splitting the inorganic waste input into the diluate and the concentrate. As expected, increasing the flowrate and the power input to each cell reduced the overall time of the process. However, mission constraints may require a longer duration process in order to reduce the power consumption. Further analysis will be required to determine the power input necessary to achieve ion diffusion effectively and in a timely manner.

Ion Exchange Membranes↗

Cost projections for Redox Energy storage systems

A preliminary design and system cost analysis was performed for the redox energy storage system. A conceptual design and cost estimate was prepared for each of two energy applications: (1) electric utility 100-MWh requirement (10-MW for ten hours) for energy storage for utility load leveling application, and (2) a 500-kWh requirement (10-kW for 50 hours) for use with a variety of residential or commercial applications, including stand alone solar photovoltaic systems. The conceptual designs were based on cell performance levels, system design parameters, and special material costs. These data were combined with estimated thermodynamic and hydraulic analysis to provide preliminary system designs. Results indicate that the redox cell stack to be amenable to mass production techniques with a relatively low material cost.

Michaels, K.↗

PON1Q192R genetic polymorphism modifies organophosphorous pesticide effects on semen quality and DNA integrity in agricultural workers from southern Mexico

Pesticide exposure, including organophosphorous (OP) insecticides, has been associated with poor semen quality, and paraoxonase (PON1), an enzyme involved in OP deactivation, may have a role on their susceptibility, due to PON1 polymorphisms. Our objective was to evaluate the role of PON1Q192R polymorphism on the susceptibility to OP toxicity on semen quality and DNA integrity in agricultural workers. A cross-sectional study was conducted in farmers with Mayan ascendancy from southeastern Mexico chronically exposed to pesticides; mostly OP. Fifty four agricultural workers (18-55 years old) were included, who provided semen and blood samples. Semen quality was evaluated according to WHO, sperm DNA damage by in situ-nick translation (NT-positive cells), PON1Q192R polymorphism by real-time PCR and serum PON1 activity by using phenylacetate and paraoxon. Two OP exposure indexes were created: at the month of sampling and during 3 months before sampling, representing the exposure to spermatids-spermatozoa and to cells at one spermatogenic cycle, respectively. PON1 192R and 192Q allele frequencies were 0.54 and 0.46, respectively. Significant associations were found between OP exposure at the month of sampling and NT-positive cells and sperm viability in homozygote 192RR subjects, and dose-effect relationships were observed between OP exposure during 3 months before sampling and sperm quality parameters and NT-positive cells in homozygote 192RR farmers. This suggests that cells at all stages of spermatogenesis are target of OP, and that there exists an interaction between OP exposure and PON1Q192R polymorphism on these effects; farmers featuring the 192RR genotype were more susceptible to develop reproductive toxic effects by OP exposure.

60 APPLIED LIFE SCIENCES↗

The DNA glycosylases OGG1 and NEIL3 influence differentiation potential, proliferation, and senescence-associated signs in neural stem cells

Highlights: Black-Right-Pointing-Pointer DNA glycosylases OGG1 and NEIL3 are required for neural stem cell state. Black-Right-Pointing-Pointer No effect on cell viability by OGG1 or NEIL3 knockdown in neural stem cells. Black-Right-Pointing-Pointer OGG1 or NEIL3 RNA knockdown result in decreased proliferation and differentiation. Black-Right-Pointing-Pointer Increased HP1{gamma} immunoreactivity after NEIL3 knockdown suggests premature senescence. -- Abstract: Embryonic neural stem cells (NSCs) exhibit self-renewal and multipotency as intrinsic characteristics that are key parameters for proper brain development. When cells are challenged by oxidative stress agents the resulting DNA lesions are repaired by DNA glycosylases through the base excision repair (BER) pathway as a means to maintain the fidelity of the genome, and thus, proper cellular characteristics. The functional roles for DNA glycosylases in NSCs have however remained largely unexplored. Here we demonstrate that RNA knockdown of the DNA glycosylases OGG1 and NEIL3 decreased NSC differentiation ability and resulted in decreased expression of both neuronal and astrocytic genes after mitogen withdrawal, as well as the stem cell marker Musashi-1. Furthermore, while cell survival remained unaffected, NEIL3 deficient cells displayed decreased cell proliferation rates along with an increase in HP1{gamma} immunoreactivity, a sign of premature senescence. Our results suggest that DNA glycosylases play multiple roles in governing essential neural stem cell characteristics.

60 APPLIED LIFE SCIENCES↗

Study of etching rate uniformity in SRF cavities

Plasma based surface modification is a promising alternative to wet etching of superconducting radio frequency (SRF) cavities. The crucial aspect of the technology development is dependence of the etching rate and surface roughness on the frequency of the power supply, pressure, power level, driven electrode shape and chlorine concentration in the gas mixture during plasma processing. To optimize the plasma parameters, we are using a single cell cavity with 20 sample holders symmetrically distributed over the cell. These holders are used as diagnostic ports for the measurement of the plasma parameters and as holders for the samples to be etched. The plasma properties are highly correlated with the shape of the driven electrode and chlorine concentration in the Argon/Chlorine gas mixtures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Etching of Niobium Sample Placed on Superconducting Radio Frequency Cavity Surface in Ar/CL2 Plasma

Plasma based surface modification is a promising alternative to wet etching of superconducting radio frequency (SRF) cavities. It has been proven with flat samples that the bulk Niobium (Nb) removal rate and the surface roughness after the plasma etchings are equal to or better than wet etching processes. To optimize the plasma parameters, we are using a single cell cavity with 20 sample holders symmetrically distributed over the cell. These holders serve the purpose of diagnostic ports for the measurement of the plasma parameters and for the holding of the Nb sample to be etched. The plasma properties at RF (100 MHz) and MW (2.45 GHz) frequencies are being measured with the help of electrical and optical probes at different pressures and RF power levels inside of this cavity. The niobium coupons placed on several holders around the cell are being etched simultaneously. The etching results will be presented at this conference.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of the properties of silicon-based semiconductor converters for betavoltaic cells

Silicon p-i-n diodes are studied in a scanning electron microscope under conditions simulating the β-radiation from a radioactive Ni{sup 63} source with an activity of 10 mCi/cm{sup 2}. The attainable parameters of β-voltaic cells with a source of this kind and a silicon-based converter of β-particle energy to electric current are estimated. It is shown that the power of elements of this kind can reach values of ∼10 nW/cm{sup 2} even for a cell with an area of one centimeter, which is rather close to the calculated value.

36 MATERIALS SCIENCE↗