Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building case study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Net Zero Energy Analysis Approach for Military Installations

Net zero energy is a concept of energy self-sufficiency based on minimized demand and use of local renewable energy resources. A net zero energy military installation is defined as: 'A military installation that produces as much energy on-site from renewable energy generation or through the on-site use of renewable fuels, as it consumes in its buildings, facilities, and fleet vehicles.' [1] TheNational Renewable Energy Laboratory (NREL) developed a comprehensive, first-of-its-kind strategy for evaluating a military installation's potential to achieve net zero energy status, including an assessment of baseline energy use, energy use reduction opportunities from efficiency or behavior changes, renewable energy generation opportunities, electrical systems analysis of renewableinterconnection, microgrid potential, and transportation energy savings. This paper describes NREL's net zero energy assessment strategy and provides a planning guide for other organizations interested in evaluating net zero potential. We also present case studies and describe lessons learned from NREL's net zero energy assessments at seven installations, including the importance of enforcing and funding mandates, providing leadership support, collecting accurate data, and selecting appropriate technologies. Finally, we evaluate whether the net zero concept is a useful framework for analyzing an energy strategy and a reasonable goal.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

NorthernStar Zero Energy Ready Homes

This is a repository for all NorthernSTAR Zero Energy Ready certified homes. Amaris Homes Model Home - St. Paul, MN 55110 Description: Model home completed September 2013 The DOE Zero Energy Ready Home Case Study looks to study and eventually design zero net energy homes in cold weather climates. These zero net energy homes are referred to as challenge homes. For this challenge home, Amaris Homes is working with the DOE in St. Paul, Minnesota. The household located at MN 55110 acts as the Amaris Challenge Home Test. The resources include technical drawings including siding, roofing and Windows. Christian Builders Challenge Home - House Count: 1 - Otsego, MN 55374 Need pictures from builder; This home actually narrowly missed certification under DOE Net Zero Energy Ready Homes. Need building plans and project summary from builder. DESIGN AND STRUCTURE - Amaris Homes - House Count: 7 Stillwater, MN 55082; Vadnais Heights, MN 55127; Bloomington, MN 55437; Apple Valley, MN 55124; White Bear Lake, MN 55110; Mounds View, MN 55112; Midland, MI 48642; DOE Zero Energy Ready Homes

Array↗

Numerical Uncertainties vs. Model Uncertainties in Two-phase Flow Simulations

In recent years, verification, validation and uncertainty quantification (VVUQ) have become a common practice in thermal-hydraulics analysis. In general, these activities deal with propagations of uncertainties in computer code simulations, e.g., through system analysis codes. However, most existing such activities in thermal-hydraulics analysis have been primarily focused on model uncertainties, while numerical uncertainties were largely overlooked. Numerical uncertainties (or numerical errors) can appear in many different forms, e.g., round-off error, statistical sampling error, and discretization error. As pointed out by Oberkampf and Roy, discretization error is usually the largest however the most difficult type of error to estimate reliably. In thermal-hydraulics analysis, especially two-phase flow simulations commonly encountered in reactor safety analysis, the lack of consideration on discretization error is mainly due to the difficulty in estimating them. Accurate estimations on discretization error require continuous mesh refinement and/or implementation of high-order numerical schemes in system analysis code, both of which are unfortunately difficult to achieve for existing codes. At first, it should be emphasized that mesh refinement (or mesh sensitivity study) is a well-understood concept in the thermal-hydraulics field. However, it is not commonly practiced for many reasons, e.g., lack of understanding on numerical errors by code users, consideration on computational cost, deteriorated numerical stability performance with refined meshes, and etc. Secondly, high-order (e.g., second-order) numerical schemes are simply unavailable in almost any existing system analysis code. Implementation of high-order numerical schemes in these codes is difficult, if not impossible, given the complexity of these codes. On the other hand, people tend to argue that numerical uncertainties (or discretization error as we have emphasized) are not as important as the commonly large uncertainties in two-phase flow models, e.g., closure correlations. As a result, nodalization is sometimes played unintentionally, or maybe intentionally, to match experimental data, which is referred as 'user effects' or 'compensating errors' in thermal-hydraulics community. Such a practice is highly criticized by Levy. In this work, we will at first build a computer code that incorporates both first-order and second-order numerical methods to solve the two-phase flow problems. The first-order method resembles the one used in many existing system analysis codes; and the second-order method works as the reference to estimate numerical errors. Numerical verifications on spatial discretization schemes will be presented in the form of mesh convergence study. It will also be demonstrated that, in practical scenarios, discretization errors can be as large as, or even larger than, model uncertainties via case studies.

42 ENGINEERING↗

Biparametric investigation of the general standard map: multistability and global bifurcations

We investigate multistability and global bifurcations in the general standard map, a biparametric two-dimensional map. Departing from the conservative case of the map, we describe the evolution of periodic solutions and their basins of attraction as dissipation builds up, paying special attention on how the biparametric variation affects multistability. We examine general and specific phenomena and behavior for three distinct dynamical regimes, namely small, moderate, and large damping and different forcing amplitudes. Also, we report numerically the mechanism of global bifurcations associated to small chaotic attractors in the multistable system. Several global bifurcations are investigated as dissipation increases. Specifically, through the characterization of an interior, a merging and a boundary crisis, we study the crucial role played by fundamental hyperbolic invariant structures, such as unstable periodic orbits and their stable and unstable invariant manifolds, in the mechanisms by which the phase space is globally transformed.

97 MATHEMATICS AND COMPUTING↗

Assessing the Energy Savings of Tankless Water Heater Retrofits in Public Housing

This report describes the methodology, analysis, and findings from a case study of a 110 unit retrofit of gas tankless water heaters in a hot/humid climate in Alachua County, Florida. The gas-fired tank type water heaters in the housing units were replaced with gas-fired tankless water heaters as part of a federal program that targeted reduced energy use in public housing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Addressing Regulatory Burdens to Accessing Solar Among Municipal, Commercial and Institutional Customers Through Collaborative Partnerships (Final Technical Report)

The project focused on providing education to large energy customers, with a focus on local governments, to help them better understand and overcome barriers to solar energy adoption that currently exist (or could exist) in utility planning processes and/or within wholesale energy markets. The project team created accessible educational materials — ranging from reports to case studies to webinars — that could connect with stakeholders who rarely engage in these venues, have limited bandwidth to do so, and possess little previous knowledge of these issues. The project team focused on sharing lessons learned and best practices based on the experiences of other local governments and large energy users that have engaged on these issues, including the PJM Cities and Communities Coalition (PJMCCC). The project sought to better connect these customers and other stakeholders to deepen and expand opportunities for them to engage together on these issues, as well as build peer networks to facilitate the exchange of information. The project team held convenings of key partners — such as local governments, developers, regulators, utilities and large solar buyers — to discuss best practices, develop research products to broaden stakeholders’ knowledge base, and to foster these peer networks.

14 SOLAR ENERGY↗

Development of an in-line filter to prevent intrusion of NO2 toxic vapors into A/C systems

The hypergolic propellant nitrogen tetroxide (N2O4 or NTO) is routinely used in spacecraft launched at Kennedy Space Center (KSC) and Cape Canaveral Air Station (CCAS). In the case of a catastrophic failure of the spacecraft, there would be a release of the unspent propellant in the form of a toxic cloud. Inhalation of this material at downwind concentrations which may be as high as 20 parts per million (ppm) for 30 minutes in duration, may produce irritation to the eyes, nose and respiratory tract. Studies at both KSC and CCAS have shown that the indoor concentrations of N2O4 during a toxic release may range from 1 to 15 ppm and depend on the air change rate (ACR) for a particular building and whether or not the air conditioning (A/C) system has been shut down or left in an operating mode. This project was initiated in order to assess how current A/C systems could be easily modified to prevent personnel from being exposed to toxic vapors. A sample system has been constructed to test the ability of several types of filter material to capture the N2O4 vapors prior to their infiltration into the A/C system. Test results will be presented which compare the efficiencies of standard A/C filters, water wash systems, and chemically impregnated filter material in taking toxic vapors out of the incoming air stream.

Meneghelli, Barry↗

DOE ZERH Case Study: Mandalay Homes, Vision Hill Lot 1, Glendale, AZ

Case study of a DOE 2015 Housing Innovation Award winning production home in the hot-dry climate that got a HERS 52 without PV, or HERS -2 with PV, with 2x6 16” on center walls with R-14 ocsf plus R-4 rigid exterior; slab on grade with R-8 slab edge; sealed attic with R-31 ocsf under roof deck; 92 AFUE furnace, 15 SEER AC, 100% LED.

Building America↗

DOE ZERH Case Study: TC Legend Homes, Bellingham Power House, Bellingham, WA

Case study of a DOE 2015 Housing Innovation Award winning custom home in the marine climate that got HERS 34 without PV or HERS -12 with PV, with 6” SIP walls and 10” SIP roof; R-28 ICF around slab, R-20 rigid foam under slab; radiant floor heat and passive design; air-to-water heat pump COP 4.4; HRV; earth tube ventilation; triple-pane windows, 100% LED.

Building America↗

A Multi-scale, Geo-data Science Method for Assessing Unconventional Critical Mineral Resources

Critical minerals (CM) supply raw materials that constitute many of our essential infrastructure, defense, technology, and electrification needs. Currently, production and refinement of these materials from conventional sources is limited to few regions globally, which makes supply of these resources particularly venerable to disruption. To help overcome these risks and meet growing demand, attention has focused on identifying and developing resource potential of unconventional geologic CM sources, such as rare-earth elements in sedimentary systems. However, the unconventional nature of these types of sources means they are often poorly characterized and/or under-explored with respect to conventional counterparts. We present a regional case study for an Unconventional Rare-earth and Critical minerals (URC) assessment method for predicting and identifying REE resource potential and occurrence in unconventional systems in the Central Appalachian Basin (CAB). The method utilizes a geologic and geospatial data-driven approach, informed and guided by knowledge of REE enrichment processes, to systematically predict and identify areas of higher enrichment. Results from the test case indicate locations with potential for different types of coal-REE deposits, demonstrating its utility for reducing the area of exploration and identifying sites for more detailed investigation. Building upon the regional scale assessment capability, ongoing science-based enhancements to the method will allow for finer-scale (e.g., mine-scale) predictions required to support technical and economic assessments.

Creason, Christopher↗

SNoGloDe: A Structured Nonlinear Global Decomposition Solver

Large-scale optimization problems often require decomposition strategies and customized algorithms to achieve optimal solutions within a reasonable time. Building on the work of Cao and Zavala (2019) for solving nonlinear two-stage stochastic programs to global optimality, we implement and extend their approach. We generalize to optimization problems reformulated with a block-angular constraint structure (e.g., temporal decomposition). Our framework, written in Python using Pyomo, is highly customizable and enables parallel execution of the decomposition. SNoGloDe allows tailored branching strategies, lower bounding problems, and candidate generators to leverage problem-specific knowledge. To demonstrate effectiveness, we compare SNoGloDe’s performance with Gurobi on a temporally decomposed produced water case study.

algorithms↗

Xcel Energy – LBNL ‘Beyond Widgets’ Project. Workstation Specific Lighting with Daylight Dimming Controls System Program Manual

This program manual was developed through a U.S. Department of Energy project to develop streamlined utility program approaches to the deployment of integrated systems in commercial offices. Integrated systems present deep opportunities for energy savings, however by nature these systems have additional levels of complexity and effort required for their design and energy savings assessment, which create barriers for utility incentive programs to develop streamlined cost effective incentive programs to capture these savings. This project worked with Xcel Energy in Colorado and Minnesota to select an integrated system and develop a streamlined approach to its deployment for small and large commercial offices. Xcel Energy worked with LBNL to select a workstation specific lighting system with daylight dimming controls, applied as a retrofit in commercial office spaces. Previous studies indicated a potential lighting annual energy savings of 28-63%, with an average of 47% for this system type, due to reduced fixture LPD and controls only, not including a full fixture replacement from a condition such as T8 to LED. Xcel also had a desire to incorporate this fixture replacement in their integrated system package, and as a result annual energy lighting savings are expected to be higher. FLEXLAB testing of the system for 500 lux minimum output conditions translated into a 94% annual energy savings for this system. Market analysis was developed for large and medium commercial office buildings in Xcel’s Minnesota and Colorado markets showing a potential for 48-295 and 120-672 GWh of energy savings potential for Colorado and Minnesota respectively. Total Resource Costs (TRC) vary by location and technology package used (enterprise versus non-enterprise lighting controls system), and vary from 0.29 to 1.27 and 0.06 and 0.44 for a Retrofit case, and 0.20 to 1.63 and 0.07 to 0.57 for a Replace on Burnout strategy for Colorado and Minnesota respectively. These results indicate good potential for demonstrating a strong technical and economic case for deployment of this system type in Xcel’s Colorado territory, while deployment in the Minnesota market may be advisable as well as part of a portfolio of programs, or as an effort to help shift the market into integrated systems deployment in general. It should be noted that the cost of avoided energy in both markets is significantly low ($0.07/kWh for Minnesota, $0.08/kWh for Colorado), and these TRC values would not be representative of deployment potential in other markets with higher utility rates. In addition, installation costs used for these systems may decrease with time, further enhancing their return on investment. Overall, workstation specific lighting systems with daylight dimming controls present a very strong potential for cost effective lighting energy savings, as demonstrated by the FLEXLAB test results and previous case studies. Further energy savings may be realized from the use of fixture-specific occupancy sensors as well, although this approach was not considered in this study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multilevel and multi-user sustainability assessment of farming systems

Sustainability assessment is needed to build sustainable farming systems. A broad range of sustainability concepts, methodologies and applications already exists. They differ in level, focus, orientation, measurement, scale, presentation and intended end-users. In this paper we illustrate that a smart combination of existing methods with different levels of application can make sustainability assessment more profound, and that it can broaden the insights of different end-user groups. An overview of sustainability assessment tools on different levels and for different end-users shows the complementarities and the opportunities of using different methods. In a case-study, a combination of the sustainable value approach (SVA) and MOTIFS is used to perform a sustainability evaluation of farming systems in Flanders. SVA is used to evaluate sustainability at sector level, and is especially useful to support policy makers, while MOTIFS is used to support and guide farmers towards sustainability at farm level. The combined use of the two methods with complementary goals can widen the insights of both farmers and policy makers, without losing the particularities of the different approaches. To stimulate and support further research and applications, we propose guidelines for multilevel and multi-user sustainability assessments. - Highlights: Black-Right-Pointing-Pointer We give an overview of sustainability assessment tools for agricultural systems. Black-Right-Pointing-Pointer SVA and MOTIFS are used to evaluate the sustainability of dairy farming in Flanders. Black-Right-Pointing-Pointer Combination of methods with different levels broadens the insights of different end-user groups. Black-Right-Pointing-Pointer We propose guidelines for multilevel and multi-user sustainability assessments.

54 ENVIRONMENTAL SCIENCES↗

Magnetic oxygen in transition metal oxides: A case study of Ba 2 CoO 4

Transition metal oxides (TMOs) exhibit exotic magnetic properties in both naturally formed and artificially structured materials, often difficult to understand in conventional wisdom. Magnetic insulator Ba 2 CoO 4 has mystified the community, because the CoO 4 tetrahedron is completely isolated with the nearest Co atoms far apart (~5 Å), making it impossible to account for long-range magnetic ordering seen experimentally using only Co. By theoretically investigating magnetism and relating our findings to experimental observations in bulk Ba 2 CoO 4 , we illustrate for the first time that the magnetic moment on oxygen atoms are the origin of the unexpected long-range magnetic ordering and low magnetic dimensionality. We find that the magnetic moment is not only localized on Co atoms, as assumed in all conventional data analysis, but also distributed on its tetrahedrally-coordinated O atoms. The total magnetic moment of the CoO 4 building block is 4.63μ B with the magnetic moment on Co being only 3.08μ B . Therefore, the magnetic building block is CoO 4 not Co. Furthermore, our first principles calculations are capable of explaining the origin of the unique magnetic response, including the presence of long-range magnetic ordering with two-dimensional character, and a one-dimensional magnetoelastic behavior. Having oxygen contribute to the magnetic moment will undoubtedly be identified as a universal property of magnetic TMOs, which will require a fresh look at conventional models of magnetism in TMOs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Processing ultrasonic inspection data from multiple scan patterns for turbine rotor weld build-up evaluations

The study presents a data processing methodology for weld build-up using multiple scan patterns. To achieve an overall high probability of detection for flaws with different orientations, an inspection procedure with three different scan patterns is proposed. The three scan patterns are radial-tangential longitude wave pattern, axial-radial longitude wave pattern, and tangential shear wave pattern. Scientific fusion of the inspection data is implemented using volume reconstruction techniques. The idea is to perform spatial domain forward data mapping for all sampling points. A conservative scheme is employed to handle the case that multiple sampling points are mapped to one grid location. The scheme assigns the maximum value for the grid location to retain the largest equivalent reflector size for the location. The methodology is demonstrated and validated using a realistic ring of weld build-up. Tungsten balls and bars are embedded to the weld build-up during manufacturing process to represent natural flaws. Flat bottomed holes and side drilled holes are installed as artificial flaws. Automatic flaw identification and extraction are demonstrated. Results indicate the inspection procedure with multiple scan patterns can identify all the artificial and natural flaws.

42 ENGINEERING↗

Assessment of an E10 gasoline surrogate: Qualitative and quantitative comparisons of in-cylinder spray morphology

A minimum-component gasoline fuel surrogate that captures both chemical and physical behaviors of a full-distillate fuel is needed for high-fidelity CFD simulations. This study evaluates gasoline spray characteristics in a direct-injection spark-ignition engine under motored operation. Two fuels are compared; PACE-20, which is a 9-component surrogate formulation of RD5-87, is compared with its target fuel RD5-87, which is a full-boiling range research grade E10 gasoline. The spray morphologies of both fuels are recorded for a centrally-located direct-injection 8-hole spray subject to intake air cross-flow during the early part of the intake stroke. High-speed imaging recorded scattered light of the side and axial projections of the liquid spray. Quantitative metrics were developed and employed to facilitate comparison of spray morphologies as well as to identify the transition in spray morphology due to flash boiling. This paper builds on a previous study of RD5-87 where coolant temperature (20°C–100°C), in-cylinder pressure (40–110 kPa), engine speed (650–1950 rpm), and injection pressure (60–180 bar) were systematically changed to span operating conditions with and without flash boiling. Images of the PACE-20 morphology are selected for a sub-set of operating conditions from the previous study where distinctive morphology changes occurred. Visual inspection of the images and quantitative metrics demonstrate that the PACE-20 spray morphology is equivalent to that of the RD5-87 in most cases. The exception was for changes in the ambient-gas pressure where the flash-boiling transition occurred at ∼5 kPa higher in-cylinder pressure for PACE-20. Three empirical metrics, Merging Index, Asymmetry, and Flash Index are proposed here and they were found to be useful both as quantitative comparisons of the fuel morphologies, and for identifying the transition in spray morphology due to flash boiling.

Kim, Namho↗

Enlightened Education: Solar Engineering Design to Energize School Facilities

Here, this paper explores the potential for universities, colleges, and K-12 schools to implement solar electric infrastructure projects on their campuses that not only provide financial savings but also provide learning environments and instructional opportunities for students. A recent case study at Madison College is presented for a 1.85 MW photovoltaic system that is the largest solar rooftop installation in the State of Wisconsin. The system was designed with several unique features to facilitate public access, provide students with hands-on interaction, and compare and contrast several different types of solar equipment. Special engineering design considerations should be made when installing solar on schools, and recommended practices from the Madison College experience are detailed. Madison College completed a Solar Roadmap in order to prioritize and sequence investment in solar across the multiple buildings and campus locations operated by the college. The featured installation was the first project within that plan. A ten-step guide on how to create a solar roadmap is shared, so that other schools can learn from Madison College’s experience and replicate the process for their own institutions.

14 SOLAR ENERGY↗

US DOE Perspectives on Advisory Board Effectiveness - 13539

Federal missions on the Oak Ridge Reservation began with the Manhattan Project, and continues today with major facilities supporting the Nation's Science and National Security missions. While most of the land area on the Oak Ridge Reservation is free of environmental impacts from these activities, significant legacy contamination is associated with specific facilities and past waste management areas. In 1989, the Oak Ridge Reservation (ORR) was placed on National Priorities List, and DOE established its Office of Environmental Management that same year. Three years later, in 1992, the Federal Facility Agreement for the reservation was signed. Three years afterward, the Oak Ridge Site Specific Advisory Board was established to augment ongoing public involvement activities related to Oak Ridge Reservation cleanup activities. One of the early and most impactful decisions the board made was to organize the End Use Working Group. This broad-based group of board members, DOE representatives, and members of the public was formed in 1997 to study future uses for contaminated areas of the reservation. The group was instrumental in building consensus in the Oak Ridge community regarding the long-term end state of reservation lands. The group's recommendations were a fundamental input into Record's of Decision subsequently developed to establish cleanup requirements across the ORR, and they continue to influence decisions being made today. In developing its recommendations on end states, the End Use Working Group came to the realization that long-term stewardship of contaminated areas of the reservation would be necessary, in some cases in perpetuity. It was from this concept that the Oak Ridge SSAB's 15-year involvement in stewardship would begin. A stewardship committee formed by the End Use Working Group wrote Volume 1 of the Stakeholder Report on Stewardship. This document-and its companion Volume 2, which was written a year later-form a crucial foundation for stewardship planning in Oak Ridge and have been referenced around the DOE complex as other sites consider stewardship planning. From these two broad-based initiatives, the board's focus has evolved to increasingly hone in on more specific, project-based recommendations and initiatives. The Oak Ridge Reservation Site Specific Advisory Board has been a highly effective forum for soliciting community input on Oak Ridge Reservation cleanup. Experience in Oak Ridge indicates that the utility of Board recommendations is far higher when the Board is asked to focus on broad programmatic issues, and less useful when the Board attempts to provide advice and recommendations on matters related to technical or project management issues. In Oak Ridge the Board has helped shape the program on many levels including definition of end-state cleanup objectives, budget development, program sequencing, waste management, and decisions concerning preservation of history related to missions implemented on the Oak Ridge Reservation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗