Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “aurora”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Thermal Density Functional Theory: Time-Dependent Linear Response and Approximate Functionals from the Fluctuation-Dissipation Theorem

We present that the van Leeuwen proof of linear-response time-dependent density functional theory (TDDFT) is generalized to thermal ensembles. This allows generalization to finite temperatures of the Gross-Kohn relation, the exchange-correlation kernel of TDDFT, and fluctuation dissipation theorem for DFT. Finally, this produces a natural method for generating new thermal exchange-correlation approximations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Direct Extraction of Excitation Energies from Ensemble Density-Functional Theory

A very specific ensemble of ground and excited states is shown to yield an exact formula for any excitation energy as a simple correction to the energy difference between orbitals of the Kohn-Sham ground state. This alternative scheme avoids either the need to calculate many unoccupied levels as in time-dependent density functional theory (TDDFT) or the need for many self-consistent ensemble calculations. Here, the symmetry-eigenstate Hartree-exchange (SEHX) approximation yields results comparable to standard TDDFT for atoms. With this formalism, SEHX yields approximate double excitations, which are missed by adiabatic TDDFT.

74 ATOMIC AND MOLECULAR PHYSICS↗

Predicting ductility in quaternary B 2 -like alloys

Although intermetallics with a B2-type crystal structure are typically brittle, a class of B2 intermetallics that demonstrates unusually high ductility has been reported. A set of recently developed B2-like quaternary precious metal-rare earth alloys also includes compositions with significant ductility. To predict ductility in these systems, we have adapted a computational energy-based metric based on slip systems and relative stability of planar defects, developed to predict ductility in B2 binary systems, for use with quaternary B2-like alloys. Here, the computational metric successfully predicts the experimentally-determined ductility or brittleness of 15 B2-like quaternary precious metal-rare earth and refractory alloys.

36 MATERIALS SCIENCE↗

Universal CMB 𝐵-mode spectrum from early causal tensor sources

Many early Universe scenarios predict postinflationary tensor perturbations from causality-limited, subhorizon sources. While the microphysical details may be different, as long as these sources are bounded in duration and correlation length, their tensor power spectra exhibit a universal scaling behavior at small wave number: 𝒫 ℎ ⁡(𝑘)∝𝑘 3 , corresponding to white noise on superhorizon scales at the time of production. If these early causal tensor sources (ECTs) exclusively produce gravitational waves before redshift 𝑧 ∼10 5 , this scaling is realized on all of the scales observed in the CMB, and thus yields a universal multipole distribution for the 𝐵-mode angular power spectrum. Unlike the scale-invariant distributions of inflationary 𝐵 modes, ECTs generically predict enhanced power on small scales and suppressed power on large scales, which allows these source classes to be distinguished given measurements over a sufficient range of angular scales. In this paper, we introduce a unified framework for characterizing ECTs and demonstrate how their universal infrared scaling manifests in low-frequency observables, including CMB 𝐵 modes and stochastic gravitational wave spectral densities. We illustrate this mapping with representative case studies of this universality class involving first-order phase transitions, topological defects, and enhanced scalar perturbations, which source tensor modes at second order in perturbation theory.

79 ASTRONOMY AND ASTROPHYSICS↗

Large-scale white noise and cosmology

The generation of white noise on large scales is a generic property of the dynamics of physical systems described by local nonlinear partial differential equations. Nonlinearities prevent the small-scale dynamics from being erased by smoothing. Unresolved small-scale dynamics act as an uncorrelated (white or Poissonian) noise (seemingly stochastic but actually deterministic) contribution to large-scale dynamics. This white noise exists even when the dynamics is very nearly linear. In cases where the power spectrum is sub-Poissonian on large scales, this noise will dominate on the largest scale power no matter the amplitude of the inhomogeneities. Such is the case in the standard model of cosmology, where the primordial density power spectrum is expected to have an almost Harrison-Zel’dovich, P [ k ] ∼ k , spectrum on a much broader range of scales than can be observed. Even though linear gravitational evolution dominates nonlinear corrections by a factor of ∼ 10 5 , the nonobservation of white noise on the Hubble scale precludes the extrapolation of this power law below the comoving 1 pc scale. More generally, observation or nonobservation of large-scale white noise provides a powerful probe of the Universe on very small scales in the early Universe. Gravitational radiation, phase transitions, vorticity, and running of the spectral index are all phenomena that can be probed with large-scale white noise. Large-scale white noise is a nonoptional feature of all cosmological models but one which has not heretofore been appreciated.

Barenboim, Gabriela [Valencia U., IFIC; Valencia U↗

Geant4 simulation of clinical proton and carbon ion beams for the treatment of ocular melanomas with the full 3-D pencil beam scanning system

This work investigates the possibility to use carbon ion beams delivered with active scanning modality, for the treatment of ocular melanomas at the Centro Nazionale di Adroterapia Oncologica (CNAO) in Pavia. The radiotherapy with carbon ions offers many advantages with respect to the radiotherapy with protons or photons, such as a higher relative radio-biological effectiveness (RBE) and a dose release better localized to the tumor. The Monte Carlo (MC) Geant4 10.00 patch-03 toolkit is used to reproduce the complete CNAO extraction beam line, including all the active and passive components characterizing it. The simulation of proton and carbon ion beams and radiation scanned field is validated against CNAO experimental data. For the irradiation study of the ocular melanoma an eye-detector, representing a model of a human eye, is implemented in the simulation. Each element of the eye is reproduced with its chemical and physical properties. Inside the eye-detector a realistic tumor volume is placed and used as the irradiation target. A comparison between protons and carbon ions eye irradiations allows to study possible treatment benefits if carbon ions are used instead of protons. (authors)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An electric-circuit model on the inter-tape contact resistance and current sharing for REBCO cable and magnet applications

REBCO coated conductor has demonstrated high current capacity that can enable high-field magnets for high energy physics and fusion applications. However, quench protection is still one of the main challenges to be addressed for these applications. In addition, Ic and n value variations along the length of REBCO tapes exist in commercial production. The inter-tape contact resistance plays a key role to develop the self protection capability in cables and magnets by enabling current sharing and suppressing excessive eddy currents. Here we propose an electric-circuit model to describe the inter-tape contact resistance and its impact on the current sharing between REBCO tapes. We report the experiments on a 2-stacked tape REBCO cable with local Ic drop to validate the model. With the developed model, we study the upper limit of the contact resistance which allows current sharing between tapes. We also study the impact of variation in Ic and n values in tapes on the cable performance. Finally, our model is expected to provide useful insight into the current sharing and target values for inter-tape contact resistance in REBCO cables and magnets for various applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Enhancing the Q-Factor of a Practical Qubit Niobium Three-Dimensional λ/4-Resonator Through Surface Treatment

Quantum computing stands as a revolutionary frontier in information technology, with the potential to solve complex problems far beyond the capacity of classical computers. At the heart of this disruptive innovation are qubits, forming the fundamental backbone of quantum computing. A leading-edge solution for constructing robust, enduring qubits involves embedding a Josephson junction within a high Q-factor, superconducting three-dimensional cavity. Further, our recent innovation lies in developing a uniquely optimized, quarter-wave resonator-based superconducting cavity, functioning at 6 GHz, specifically tailored for quantum computers. In this work, we elucidate our advancement towards elevating the Q-factor tenfold, an achievement made possible through the enhancement of machining precision, the application of rigorous postprocessing techniques—including mechanical, chemical, and surface treatments—as well as the refinement of our testing methods.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Robust Spectral Unmixing of Sparse Multispectral Lidar Waveforms using Gamma Markov Random Fields

Here, this paper presents a new Bayesian spectral un-mixing algorithm to analyse remote scenes sensed via sparse multispectral Lidar measurements. To a first approximation, in the presence of a target, each Lidar waveform consists of a main peak, whose position depends on the target distance and whose amplitude depends on the wavelength of the laser source considered (i.e, on the target reflectivity). Besides, these temporal responses are usually assumed to be corrupted by Poisson noise in the low photon count regime. When considering multiple wavelengths, it becomes possible to use spectral information in order to identify and quantify the main materials in the scene, in addition to estimation of the Lidar-based range profiles. Due to its anomaly detection capability, the proposed hierarchical Bayesian model, coupled with an efficient Markov chain Monte Carlo algorithm, allows robust estimation of depth images together with abundance and outlier maps associated with the observed 3D scene. The proposed methodology is illustrated via experiments conducted with real multispectral Lidar data acquired in a controlled environment. The results demonstrate the possibility to unmix spectral responses constructed from extremely sparse photon counts (less than 10 photons per pixel and band).

97 MATHEMATICS AND COMPUTING↗

Virtual Critical Coupling in High-Power Resonant Systems

Power reflections are a fundamental challenge in high-power resonant systems, causing energy loss, limiting per- formance, and potentially damaging critical components. This problem is particularly acute in applications such as lower hybrid current drive (LHCD) for tokamak-based nuclear fusion, where efficient, stable power transfer to the plasma is paramount. In this work, we introduce and experimentally demonstrate the virtual critical coupling (VCC) mechanism, a nonmechanical method to achieve reflection-free excitation in high-power S-band resonators. VCC utilizes a temporally shaped excitation signal with a precise complex frequency, tailored to the resonator’s characteristics to enable complete energy absorption. Using a custom low-level RF system and a 5-MW S-band klystron, we conducted experiments from low power (32 mW) to high power (600 kW). Furthermore, the results demonstrate a greater than ninefold reduction in the reflection coefficient compared to conventional monochromatic excitation. This signal processing-based approach offers a robust path toward enhancing the efficiency and stability of high-power resonant systems, with significant implications for particle accelerators and the advancement of nuclear fusion energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The intrinsically disordered nature of the peroxisomal protein translocation machinery

Despite having a membrane that is impermeable to all but the smallest of metabolites, peroxisomes acquire their newly synthesized (cytosolic) matrix proteins in an already folded conformation. In some cases, even oligomeric proteins have been reported to translocate the organelle membrane. The protein sorting machinery that accomplishes this feat must be rather flexible and, unsurprisingly, several of its key components have large intrinsically disordered domains. Here, we provide an overview on these domains and their interactions trying to infer their functional roles in this protein sorting pathway.

Barros‐Barbosa, Aurora↗

Ground calibration plan for the Athena/X-IFU microcalorimeter spectrometer

The X-ray Integral Field Unit is the X-ray imaging spectrometer on board one of ESA’s next large missions, Athena. Athena is set to investigate the theme of the Hot and Energetic Universe, with a launch planned in the late-2030s. Based on a high-sensitivity transition edge sensor (TES) detector array operated at very low temperature (50 mK), X-IFU will provide spatially resolved high-resolution spectroscopy of the X-ray sky in the 0.2 to 12 keV energy band, with an energy resolution goal of 4 eV up to 7 keV [3 eV design goal]. This work presents the current calibration plan of the X-IFU. It provides the requirements applicable to the X-IFU calibration, describes the overall calibration strategy, and details the procedure and sources needed for the ground calibration of each parameter or characteristics of the X-IFU.

47 OTHER INSTRUMENTATION↗

Optical eye tracking system for real-time noninvasive tumor localization in external beam radiotherapy

Purpose: External beam radiotherapy currently represents an important therapeutic strategy for the treatment of intraocular tumors. Accurate target localization and efficient compensation of involuntary eye movements are crucial to avoid deviations in dose distribution with respect to the treatment plan. This paper describes an eye tracking system (ETS) based on noninvasive infrared video imaging. The system was designed for capturing the tridimensional (3D) ocular motion and provides an on-line estimation of intraocular lesions position based on a priori knowledge coming from volumetric imaging. Methods: Eye tracking is performed by localizing cornea and pupil centers on stereo images captured by two calibrated video cameras, exploiting eye reflections produced by infrared illumination. Additionally, torsional eye movements are detected by template matching in the iris region of eye images. This information allows estimating the 3D position and orientation of the eye by means of an eye local reference system. By combining ETS measurements with volumetric imaging for treatment planning [computed tomography (CT) and magnetic resonance (MR)], one is able to map the position of the lesion to be treated in local eye coordinates, thus enabling real-time tumor referencing during treatment setup and irradiation. Experimental tests on an eye phantom and seven healthy subjects were performed to assess ETS tracking accuracy. Results: Measurements on phantom showed an overall median accuracy within 0.16 mm and 0.40° for translations and rotations, respectively. Torsional movements were affected by 0.28° median uncertainty. On healthy subjects, the gaze direction error ranged between 0.19° and 0.82° at a median working distance of 29 cm. The median processing time of the eye tracking algorithm was 18.60 ms, thus allowing eye monitoring up to 50 Hz. Conclusions: A noninvasive ETS prototype was designed to perform real-time target localization and eye movement monitoring during ocular radiotherapy treatments. The device aims at improving state-of-the-art invasive procedures based on surgical implantation of radiopaque clips and repeated acquisition of X-ray images, with expected positive effects on treatment quality and patient outcome.

60 APPLIED LIFE SCIENCES↗

Performance evaluation of a high resolution dedicated breast PET scanner

Purpose: Early stage breast cancers may not be visible on a whole-body PET scan. To overcome whole-body PET limitations, several dedicated breast positron emission tomography (DbPET) systems have emerged nowadays aiming to improve spatial resolution. In this work the authors evaluate the performance of a high resolution dedicated breast PET scanner (Mammi-PET, Oncovision). Methods: Global status, uniformity, sensitivity, energy, and spatial resolution were measured. Spheres of different sizes (2.5, 4, 5, and 6 mm diameter) and various 18 fluorodeoxyglucose ({sup 18}F-FDG) activity concentrations were randomly inserted in a gelatine breast phantom developed at our institution. Several lesion-to-background ratios (LBR) were simulated, 5:1, 10:1, 20:1, 30:1, and 50:1. Images were reconstructed using different voxel sizes. The ability of experienced reporters to detect spheres was tested as a function of acquisition time, LBR, sphere size, and matrix reconstruction voxel size. For comparison, phantoms were scanned in the DbPET camera and in a whole body PET (WB-PET). Two patients who just underwent WB-PET/CT exams were imaged with the DbPET system and the images were compared. Results: The measured absolute peak sensitivity was 2.0%. The energy resolution was 24.0% ± 1%. The integral and differential uniformity were 10% and 6% in the total field of view (FOV) and 9% and 5% in the central FOV, respectively. The measured spatial resolution was 2.0, 1.9, and 1.7 mm in the radial, tangential, and axial directions. The system exhibited very good detectability for spheres ≥4 mm and LBR ≥10 with a sphere detection of 100% when acquisition time was set >3 min/bed. For LBR = 5 and acquisition time of 7 min the detectability was 100% for spheres of 6 mm and 75% for spheres of 5, 4, and 2.5 mm. Lesion WB-PET detectability was only comparable to the DbPET camera for lesion sizes ≥5 mm when acquisition time was >3 min and LBR > 10. Conclusions: The DbPET has a good performance for its clinical use and shows an improved resolution and lesion detectability of small lesions compared to WB-PET.

60 APPLIED LIFE SCIENCES↗

Defect-mediated ferromagnetism in correlated two-dimensional transition metal phosphorus trisulfides

Controlling the magnetic spin states of two-dimensional (2D) van der Waals (vdW) materials with strong electronic or magnetic correlation is important for spintronic applications but challenging. Crystal defects that are often present in 2D materials such as transition metal phosphorus trisulfides (MPS 3 ) could influence their physical properties. Here, we report the effect of sulfur vacancies on the magnetic exchange interactions and spin ordering of few-layered vdW magnetic Ni 1-x Co x PS 3 nanosheets. Magnetic and structural characterization in corroboration with theoretical calculations reveal that sulfur vacancies effectively suppress the strong intralayer antiferromagnetic correlation, giving rise to a weak ferromagnetic ground state in Ni 1-x Co x PS 3 nanosheets. Notably, the magnetic field required to tune this ferromagnetic state (<300 Oe) is much lower than the value needed to tune a typical vdW antiferromagnet (> several thousand oersted). These findings provide a previously unexplored route for controlling competing correlated states and magnetic ordering by defect engineering in vdW materials.

36 MATERIALS SCIENCE↗