Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “acquisition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Regional program for acquisition of medical experiments

A U.S. company was contracted to cover different regions of the country. A moderately detailed description of the highlights of the company activities along with some conclusions and recommendations are reported. In summary, the regional program effectively: (1) informed segments of the medical community of research opportunities; (2) validated formats for regional workshops; (3) assisted potential investigators with follow-up consultations and proposal preparations; and (4) identified a latent intersect requiring continual dialog at the scientist/engineer interface for successful cultivation and integration.

Vannordstrand, P. C.↗

A long-range and long-life telemetry data-acquisition system for heart rate and multiple body temperatures from free-ranging animals

The system includes an implantable transmitter, external receiver-retransmitter collar, and a microprocessor-controlled demodulator. The size of the implant is suitable for animals with body weights of a few kilograms or more; further size reduction of the implant is possible. The ECG is sensed by electrodes designed for internal telemetry and to reduce movement artifacts. The R-wave characteristics are then specifically selected to trigger a short radio frequency pulse. Temperatures are sensed at desired locations by thermistors and then, based on a heartbeat counter, transmitted intermittently via pulse interval modulation. This modulation scheme includes first and last calibration intervals for a reference by ratios with the temperature intervals to achieve good accuracy even over long periods. Pulse duration and pulse sequencing are used to discriminate between heart rate and temperature pulses as well as RF interference.

Lund, G. F.↗

Recycling isoelectric focusing with computer controlled data acquisition system

Isoelectric focusing is a high-resolution technique for separating and purifying large peptides, proteins, and other biomolecules. The apparatus described in the present paper constitutes a new approach to fluid stabilization and increased throughput. Stabilization is achieved by flowing the process fluid uniformly through an array of closely spaced filter elements oriented parallel both to the electrodes and the direction of the flow. This seems to overcome the major difficulties of parabolic flow and electroosmosis at the walls, while limiting the convection to chamber compartments defined by adjacent spacers. Increased throughput is achieved by recirculating the process fluid through external heat exchange reservoirs, where the Joule heat is dissipated.

Egen, N. B.↗

Automated time-resolved data acquisition during static and dynamic loading of composite materials

This paper reports the development of two new nondestructive techniques for precise determination of the nature and extent of complex damage and the consequent redistribution of stress in composite materials during quasi-static and cyclic or dynamic loading. The two methods incorporate video-thermography and four-component tensor elastic modulus determination. The experimental and analytical aspects of these two methods are discussed and data is presented.

Reifsnieder, K. L.↗

High rate data acquisition from Spacelab/Shuttle

The need for high data rates from a variety of experiments on Spacelab/Shuttle produced the requirement for the Spacelab High Rate Multiplexer/Demultiplexer system. This system acquires serial digital data at asynchronous bit rates from up to sixteen experiments, two data buses, three voice links, two tape recorders, and a universal time channel. Experiment data rates may vary from 200 bps to 16 Mbps while recorded data rates range from 250 Kbps to 32 Mbps. The High Rate Multiplexer (HRM) accepts these data inputs and forms a serial PCM output at flexible rates up to 48 Mbps. This PCM output is transmitted to ground by a Ku-Band RF link via the Tracking and Data Relay Satellite System (TDRSS) or recorded on board for delayed transmission. A complementary ground based High Rate Demultiplexer (HRDM) accepts and demultiplexes the composite PCM data at ground processing locations.

Coffey, R.↗

Space Shuttle data acquisition and processing

The techniques of minimizing the amount of Space Shuttle data processed by using real-time ground data and on board computer to prescreen the data are presented. With the advent of long duration space flight and the large amounts of data generated, it became necessary to limit the amount of data to be processed and also to present data in a manner that highlights the most important data. The Shuttle operational data system with output of 128 kilobits/sec, the developmental flight instrumentation system, and screening of data by the analysts, flight crew, or onboard computers is described, noting that by using these monitoring methods the mission evaluation team can rapidly determine time periods for which postflight data processing is required. Postflight processing systems, batch system output products, data compression techniques, the interactive computer system, and the special telemetry conversion system are discussed, and it is concluded that the combination of Shuttle on board and ground data processing systems enhances the ability to perform a functional evaluation of the Space Shuttle vehicle.

Foster, G. B., Jr.↗

Data-acquisition and control system for severe environments

Report evaluates control system by measuring accuracy and performance of system subcomponents, including interface wiring unit, power controller, and tape recorder. Test parameters establish variety of severe operation environments. Text features test program descriptions, sample readouts, and results. Summary of custom solar system simulator is included.

Source record↗

Cardiopulmonary data-acquisition system

Computerized system controls and monitors bicycle and treadmill cardiovascular stress tests. It acquires and reduces stress data and displays heart rate, blood pressure, workload, respiratory rate, exhaled-gas composition, and other variables. Data are printed on hard-copy terminal every 30 seconds for quick operator response to patient. Ergometer workload is controlled in real time according to experimental protocol. Collected data are stored directly on tape in analog form and on floppy disks in digital form for later processing.

Crosier, W. G.↗

Automatic Data Processing Equipment (ADPE) acquisition plan for the medical sciences

An effective mechanism for meeting the SLSD/MSD data handling/processing requirements for Shuttle is discussed. The ability to meet these requirements depends upon the availability of a general purpose high speed digital computer system. This system is expected to implement those data base management and processing functions required across all SLSD/MSD programs during training, laboratory operations/analysis, simulations, mission operations, and post mission analysis/reporting.

Source record↗

Ancillary data acquisition for LACIE

The design, implementation, and operational functions of the three phases of LACIE supported the data needs of all other elements of the project and required several types of data in addition to LANDSAT multispectral digital data. The nonelectronic data base consisted of statistical data, printed reports, periodicals, ground observed data received from intensive test sites and operational segments, and full-frame multispectral scanner CIR photographs. The following data were collected for the test sites in the United States and Canada: land use inventories, periodic crop observations, solar radiometer measurements, rainfall, and wheat yield for selected fields.

Spiers, B. E.↗

Capillary acquisition devices for high-performance vehicles: Executive summary

Technology areas critical to the development of cryogenic capillary devices were studied. Passive cooling of capillary devices was investigated with an analytical and experimental study of wicking flow. Capillary device refilling with settled fluid was studied using an analytical and experimental program that resulted in successful correlation of a versatile computer program with test data. The program was used to predict Centaur D-1S LO2 and LH2 start basket refilling. Comparisons were made between the baseline Centaur D-1S propellant feed system and feed system alternatives including systems using capillary devices. The preferred concepts from the Centaur D-1S study were examined for APOTV and POTV vehicles for delivery and round trip transfer of payloads between LEO and GEO. Mission profiles were determined to provide propellant usage timelines and the payload partials were defined.

Blatt, M. H.↗

The telecommunications and data acquisition report

Progress in the development and operations of the Deep Space Network is reported. Developments in Earth based radio technology as applied to geodynamics, astrophysics, and radio astronomy's use of the deep space stations for a radio search for extraterrestrial intelligence in the microwave region of the electromagnetic spectrum are reported.

Source record↗