Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “X RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Radiation Tolerant Intelligent Memory Stack (RTIMS)

The Radiation Tolerant Intelligent Memory Stack (RTIMS), suitable for both geostationary and low earth orbit missions, has been developed. The memory module is fully functional and undergoing environmental and radiation characterization. A self-contained flight-like module is expected to be completed in 2006. RTIMS provides reconfigurable circuitry and 2 gigabits of error corrected or 1 gigabit of triple redundant digital memory in a small package. RTIMS utilizes circuit stacking of heterogeneous components and radiation shielding technologies. A reprogrammable field programmable gate array (FPGA), six synchronous dynamic random access memories, linear regulator, and the radiation mitigation circuitries are stacked into a module of 42.7mm x 42.7mm x 13.00mm. Triple module redundancy, current limiting, configuration scrubbing, and single event function interrupt detection are employed to mitigate radiation effects. The mitigation techniques significantly simplify system design. RTIMS is well suited for deployment in real-time data processing, reconfigurable computing, and memory intensive applications.

Ng, Tak-kwong↗

Multiscale X-ray phase contrast imaging of human cartilage for investigating osteoarthritis formation

The evolution of cartilage degeneration is still not fully understood, partly due to its thinness, low radio-opacity and therefore lack of adequately resolving imaging techniques. X-ray phase-contrast imaging (X-PCI) offers increased sensitivity with respect to standard radiography and CT allowing an enhanced visibility of adjoining, low density structures with an almost histological image resolution. This study examined the feasibility of X-PCI for high-resolution (sub-) micrometer analysis of different stages in tissue degeneration of human cartilage samples and compare it to histology and transmission electron microscopy. Ten 10%-formalin preserved healthy and moderately degenerated osteochondral samples, post-mortem extracted from human knee joints, were examined using four different X-PCI tomographic set-ups using synchrotron radiation the European Synchrotron Radiation Facility (France) and the Swiss Light Source (Switzerland). Volumetric datasets were acquired with voxel sizes between 0.7 × 0.7 × 0.7 and 0.1 × 0.1 × 0.1 µm 3 . Data were reconstructed by a filtered back-projection algorithm, post-processed by ImageJ, the WEKA machine learning pixel classification tool and VGStudio max. For correlation, osteochondral samples were processed for histology and transmission electron microscopy. X-PCI provides a three-dimensional visualization of healthy and moderately degenerated cartilage samples down to a (sub-)cellular level with good correlation to histologic and transmission electron microscopy images. X-PCI is able to resolve the three layers and the architectural organization of cartilage including changes in chondrocyte cell morphology, chondrocyte subgroup distribution and (re-)organization as well as its subtle matrix structures. X-PCI captures comprehensive cartilage tissue transformation in its environment and might serve as a tissue-preserving, staining-free and volumetric virtual histology tool for examining and chronicling cartilage behavior in basic research/laboratory experiments of cartilage disease evolution.

3D analysis↗

Wave optics simulations for new soft x-ray beamlines at NSLS-II

In this work, we performed fully- and partially-coherent synchrotron emission and propagation simulations with the "Synchrotron Radiation Workshop" computer code to analyze the performance of two soft X-ray beamlines under development at the National Synchrotron Light Source II: Soft X-ray Nanoprobe (SXN), and Angle-Resolved Photoemission Spectroscopy (ARPES) and Resonant Inelastic X-ray Scattering (RIXS) Imaging (ARI). The SXN beamline intends to provide high flux and high spatial resolution coherent soft X-ray imaging capabilities using both zone plate and lensless coherent imaging techniques. The ARI beamline aims to perform high flux ARPES and RIXS experiments with a focal spot size at the sample approaching 100 nm using highly-demagnifying mirrors in Kirkpatrick-Baez geometry. To accurately calculate the resolution and the degree of X-ray coherence provided by the two state-of-the-art beamlines, partial coherence effects are required to be taken into account in wave optics simulations for these two beamlines. In this talk, beamline performance parameters such as spot size, degree of coherence, flux, and energy resolution at the sample are presented. The effects of mirror surface slope errors on beamline performance were studied and some suggestions for further optimization are discussed.

36 MATERIALS SCIENCE↗

The X-ray nebula around PSR 1509 - 58

With the use of measured spectra and a model, volumes and luminosities are derived for several components of the supernova remnant MSH 15 - 52. The hard, featureless spectrum and spatial symmetry of the X-ray nebula surrounding the central pulsar strongly indicate synchrotron radiation as the source of emission. Power requirements are easily supplied by the pulsar. The observed surface brightness is only 0.00002 that of the X-ray synchrotron emission around the Crab pulsar, and the X-ray luminosity is 0.01 that of the Crab. In spite of the great difference in luminosity and size, the two systems are probably similar in nature, with the high brightness and unique appearance of the Crab synchrotron nebula being due to the high energy output of the pulsar and the relatively small volume of the confining filaments.

Seward, F. D.↗

Synchrotron-based Characterization Techniques for Radiation Detection Materials and Devices: An Overview

High-performance room-temperature radiation detectors (high energy resolution for spectrometers, high spatial resolution for imaging devices, and low defect-density for high flux applications) are needed for photon energies (>20 keV) that are not well suited for silicon detectors. Applications for such radiation detectors include nonproliferation, synchrotron, medical, astrophysics, and homeland security. Material- and device- characterization to understand and solve the limiting factors of radiation detection materials and devices is a core element of a radiation detector development R&D program. This presentation will give an overview on the two main synchrotron-based characterization techniques that have been employed by the authors in the last ~20 years: (1) White Beam X-ray Diffraction Topography and (2) Micron-scale detector mapping. A perfect (one domain) crystal (radiation detection material) is a requirement to achieve a highperformance radiation detector. White Beam X-ray Diffraction Topography (WBXDT) allows the rapid screening of the crystallinity of the detector material. With WBXDT we can quickly screen CZT and other crystals to make sure they have only one domain, and to see the presence of extended defects and strain fields.

Camarda, Giuseppe S.↗

High-energy observations of stellar flares - Comparison with the sun

This paper reviews recent observations of flaring activity on flare stars of the UV Ceti type, concentrating on X-ray and radio data in comparison with possible solar analogs. Although detailed differences exist, it is concluded that similar mechanisms may work for both cases. Extending the analogy, the hard X-ray and gamma ray fluxes expected from typical stellar flares are estimated. In the solar case, these radiations give information about accelerated particles in the flare region. Hard X-ray observations of stellar flares may be possible, eventually, but the predicted gamma-ray fluxes are prohibitively weak.

Hudson, H. S.↗

The effects of simulated low Earth orbit environments on spacecraft thermal control coatings

Candidate Space Station Freedom radiator coatings including Z-93, YB-71, anodized aluminum and SiO(x) coated silvered Teflon have been characterized for optical properties degradation upon exposure to environments containing atomic oxygen, vacuum ultraviolet (VUV) radiation, and/or silicone contamination. YB-71 coating showed a blue-gray discoloration, which has not been observed in space, upon exposure in atomic oxygen facilities which also provide exaggerated VUV radiation. This is evidence that damage mechanisms occur in these ground laboratory facilities which are different from those which occur in space. Radiator coatings exposed to an electron cyclotron resonance (ECR) atomic oxygen source in the presence of silicone-containing samples showed severe darkening from the intense VUV radiation provided by the ECR and from silicone contamination. Samples exposed to atomic oxygen from the ECR source and to VUV lamps, simultaneously, with in situ reflectance measurement, showed that significantly greater degradation occurred when samples received line-of-site ECR beam exposure than when samples were exposed to atomic oxygen scattered off of quartz surfaces without line-of-site view of the ECR beam. For white paints, exposure to air following atomic oxygen/VUV exposure reversed the darkening due to VUV damage. This illustrates the importance of in situ reflectance measurement.

Dever, Joyce A.↗

Radiation pressure-driven shocks in winds from hot stars

The dynamical theory of radiation-pressure-driven shocks in winds from early-type stars is outlined. After the principal parameters needed for a description of these shocks are isolated (speeds relative to incoming material and their column densities), the shocks' principal properties as functions of these parameters are estimated. The special case of time-steady shocks is examined, and calculations are given for density, ionization state, temperature, and flow velocity as functions of position; also calculated are X-ray emissivity, UV line emissivity, and total radiation force as functions of shock velocity and postshock column density.

Krolik, J. H.↗

An initiation-promotion model of tumour prevalence from high-charge and energy radiations

A repair/misrepair kinetic model for multiple radiation-induced lesions (mutation inactivation) is coupled to a two-mutation model of initiation-promotion in tissue to provide a parametric description of tumour prevalence in the mouse Harderian gland from high-energy and charge radiations. Track-structure effects are considered using an action-cross section model. Dose-response curves are described for gamma rays and relativistic ions, and good agreement with experiment is found. The effects of nuclear fragmentation are also considered for high-energy proton and alpha-particle exposures. The model described provides a parametric description of age-dependent cancer induction for a wide range of radiation fields. Radiosensitivity parameters found in the model for an initiation mutation (sigma 0 = 7.6 x 10(-10) cm2 and D0 = 148.0 Gy) are somewhat different than previously observed for neoplastic transformation of C3H10T1/2 cell cultures (sigma 0 = 0.7 x 10(-10) cm2 and D0 = 117.0 Gy). We consider the two hypotheses that radiation acts solely as an initiator or as both initiator and promoter and make model calculations for fractionation exposures from gamma rays and relativistic Fe ions. For fractionated Fe exposures, an inverse-dose-rate effect is provided by a promotion hypothesis with an increase of 30% or more, dependent on the dose level and fractionation schedule, using a mutation rate for promotion similar to that of single-gene mutations.

NASA Discipline Radiation Health↗

Skynet satellite electron precharging experiments

Large surface areas (approximately 1 sq m) of the Skynet I qualification model satellite were exposed to the environments of a flux of monoenergetic electrons and pulsed high-intensity X-ray photons from an exploding-wire-radiator source, separately and simultaneously. Experiments were performed with both the cylindrical solar cell panels and the end thermal blanket exposed to these environments. The satellite was instrumented with fiber-optics isolated fast-response sensors capable of sensing and recording the time-varying electric fields and surface currents on the satellite. Spontaneous discharges of the two surfaces were characterized prior to measurements of the interaction of the system-generated electromagnetic pulse from the X-ray photon burst with the electron precharged surfaces. A two-dimensional self-consistent finite difference computer code was used to predict the currents on the Skynet both with and without precharging of the thermal-blanket. These calculations, which used an thermal-blanket voltage profile, predicted a factor of 2 increase in satellite exterior axial currents.

Vanlint, V. A. J.↗

A radiating one-dimensional current sheet configuration

The structure of the x-independent (one-dimensional) forced current sheet including a self consistent By component is investigated for the case of small normal field component, Bz/B0 much less than 1. A hybrid (kinetic ions, massless fluid electrons) simulation model is used to demonstrate that such a current sheet has a time-dependent structure which radiates incompressible Alfven waves with amplitude of the order of the asymptotic (lobe) field strength B0. The central density enhancement acts as the source of a propagating wavetrain in which Bx rotates into By and back again. One of the characteristic signatures of the radiating current sheet is the presence of a reversal in Bx (or By) without a corresponding increase in density.

Pritchett, P. L.↗

Stability of an optically contacted etalon to cosmic radiation

An investigation has been completed to determine the effects of prolonged exposure to cosmic radiation on Zerodur spacing elements used between two dielectric reflectors on silica substrates in the plane Fabry-Perot etalon selected for flight in the Dynamics Explorer satellite. The measured radiation expansion coefficient for Zerodur is approximately -4.0 x 10 to the -12th/rad. In addition to the overall change in gap dimension, test data indicate a degradation in etalon parallelism, which is ascribed to the different doses received by the three spacers due to their differing distances from a Co-60 source. The effect is considered to be of practical use in the tuning and parallelism adjustment of fixed gap etalons. The variation is small enough not to pose a problem for the satellite instrument where expected radiation doses are less than 10,000 rads.

Killeen, T. L.↗

Effect of Space Radiation on TES Detectors Performance

The Athena mission and its X-IFU instrument (X-ray Integral Field Unit) will be positioned at the Sun-Earth Lagrangian point L1, where it will be subject to solar wind (low flux plasma of 95% protons and 5% alpha particles) with energy below 0.1 MeV, and to galactic cosmic rays and solar flares (energetic protons, alpha particles, and electrons) with energies up to hundreds of MeV for protons and the GeV for heavier ions. Some of these particles will go through the satellite and hit the focal plane assembly and hence the detectors. These detectors will be TES (Transition-edge sensor) microcalorimeters, flown for the first time in such an environment. In order to ensure the performance of this type of detectors throughout the duration of such mission, it is critical to study the impact of the radiation on their behavior. Indeed, although a lot of reference material exist for semiconductor detectors such as CCDs, little is currently known about the impact of radiation on TES detectors. These energetic events could cause local heating or damage to the detectors and affect their performance. In this work, we describe how we designed a test campaign to assess the impact of L1 radiation on TES detectors for Athena/X-IFU-like missions and present the results of the tests. Analyses includes assessing changes in the pulse shapes and energy resolution of the detectors measured at 55 mK after several radiation dose steps performed at 4 K.

Sophie Beaumont↗

A high-power, high-repetition-rate THz source for pump–probe experiments at Linac Coherent Light Source II

Experiments using a THz pump and an X-ray probe at an X-ray free-electron laser (XFEL) facility like the Linac Coherent Light Source II (LCLS II) require frequency-tunable (3 to 20 THz), narrow bandwidth (~10%), carrier-envelope-phase-stable THz pulses that produce high fields (>1 MV cm –1 ) at the repetition rate of the X-rays and are well synchronized with them. Herein, a two-bunch scheme to generate THz radiation at LCLS II is studied: the first bunch produces THz radiation in an electromagnet wiggler immediately following the LCLS II undulator that produces X-rays from the second bunch. The initial time delay between the two bunches is optimized to compensate for the path difference in THz transport. The two-bunch beam dynamics, the THz wiggler and radiation are described, as well as the transport system bringing the THz pulses from the wiggler to the experimental hall.

42 ENGINEERING↗

Three-dimensional reconstruction of laser-direct-drive inertial confinement fusion hot-spot plasma from x-ray diagnostics on the OMEGA laser facility (invited)

A deep-learning convolutional neural network (CNN) is used to infer, from x-ray images along multiple lines of sight, the low-mode shape of the hot-spot emission of deuterium–tritium (DT) laser-direct-drive cryogenic implosions on OMEGA. The motivation of this approach is to develop a physics-informed 3-D reconstruction technique that can be performed within minutes to facilitate the use of the results to inform changes to the initial target and laser conditions for the subsequent implosion. The CNN is trained on a 3D radiation-hydrodynamic simulation database to relate 2D x-ray images to 3D emissivity at stagnation. The CNN accounts for the lack of an absolute spatial reference and the different bands of photon energies in the x-ray images. While previous works studied the effect of mode-1 asymmetries on implosion performance using nuclear diagnostics, this work focuses on the effect of mode 2 inferred from x-ray diagnostics on implosion performance. A current analysis of 19 DT cryogenic implosions indicates there is an upper limit of ~20% reduction in the neutron yield caused by an ℓ = 2 amplitude for ℓ 2 /ℓ 0 ≤ 0.32. Here, these conclusions are supported by 2D simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗