Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Water System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Microbiological concerns and methodological approaches related to bacterial water quality in spaceflight

A number of microbiological issues are of critical importance to crew health and system performance in spacecraft water systems. This presentation reviews an army of these concerns which include factors that influence water treatment and disinfection in spaceflight such as biofilm formation and the physiological responses of bacteria in clean water systems. Factors associated with spaceflight like aerosol formation under conditions of microgravity are also discussed within the context of airborne infections such as Legionellosis. Finally, a spectrum of analytical approaches is reviewed to provide an evaluation of methodological alternatives that have been suggested or used to detect microorganisms of interest in water systems. These range from classical approaches employing colony formation on specific microbiological growth media to direct (i.e. microscopic) and indirect (e.g. electrochemical) methods as well as the use of molecular approaches and gene probes. These techniques are critically evaluated for their potential utility in determining microbiological water quality through the detection of microorganisms under the influence of ambient environmental stress inherent in spaceflight water systems.

Pyle, Barry H.↗

Water cycles in closed ecological systems: effects of atmospheric pressure

In bioregenerative life support systems that use plants to generate food and oxygen, the largest mass flux between the plants and their surrounding environment will be water. This water cycle is a consequence of the continuous change of state (evaporation-condensation) from liquid to gas through the process of transpiration and the need to transfer heat (cool) and dehumidify the plant growth chamber. Evapotranspiration rates for full plant canopies can range from ~1 to 10 L m-2 d-1 (~1 to 10 mm m-2 d-1), with the rates depending primarily on the vapor pressure deficit (VPD) between the leaves and the air inside the plant growth chamber. VPD in turn is dependent on the air temperature, leaf temperature, and current value of relative humidity (RH). Concepts for developing closed plant growth systems, such as greenhouses for Mars, have been discussed for many years and the feasibility of such systems will depend on the overall system costs and reliability. One approach for reducing system costs would be to reduce the operating pressure within the greenhouse to reduce structural mass and gas leakage. But managing plant growth environments at low pressures (e.g., controlling humidity and heat exchange) may be difficult, and the effects of low-pressure environments on plant growth and system water cycling need further study. We present experimental evidence to show that water saturation pressures in air under isothermal conditions are only slightly affected by total pressure, but the overall water flux from evaporating surfaces can increase as pressure decreases. Mathematical models describing these observations are presented, along with discussion of the importance for considering "water cycles" in closed bioregenerative life support systems.

NASA Center KSC↗

Pre- and posttreatment techniques for spacecraft water recovery

The objective was to develop techniques for satisfactory pretreatment of waste water (urine and wash water) prior to recovery by distillation and satisfactory post-treatment of the recovered water and humidity condensate for purification to the high quality necessary for reuse. The effort included literature and laboratory investigations, feasibility evaluations of candidate approaches, and development of conceptual designs for a waste water pretreatment system and a recovered water post-treatment system.

Putnam, David F.↗

Development of a multiphysics analysis system for sodium-water reaction phenomena in steam generators of sodium-cooled fast reactors

A multiphysics analysis system for sodium-water reaction phenomena in a steam generator of sodium-cooled fast reactors was newly developed. The analysis system consists of the mechanistic numerical analysis codes, SERAPHIM, TACT, and RELAP5. The SERAPHIM code calculates the multicomponent multiphase flow and sodium-water chemical reaction caused by discharging of pressurized water vapor. Applicability of the SERAPHIM code was confirmed through the analyses of the experiment on water vapor discharging in liquid sodium. The TACT code was developed to calculate heat transfer from the reacting jet to the adjacent tube and to predict the tube failure occurrence. The numerical models integrated into the TACT code were verified through some related experiments. The RELAP5 code evaluates thermal hydraulic behavior of water inside the tube. The original heat transfer correlations were corrected for the tube rapidly heated by the reacting jet. The developed system enables evaluation of the wastage environment and the possibility of the failure propagation.

42 ENGINEERING↗

Greenbuilt Construction Energy Efficiency Retrofit House Demonstration - Sacramento

One of the homes that was part of Sacramento Municipal Utility District's (SMUD) Energy Efficiency Retrofit Demonstration (EERD) project was a 1980's era home in Fair Oaks, California, referred to as the Greenbuilt house, as Greenbuilt Construction completed the retrofit of the home. The home underwent an extensive energy efficiency retrofit with a goal of achieving a 50% reduction in energy use to demonstrate the potential for other builders and homeowners in the area. The retrofit measures included installing: ENERGY STAR appliances high efficiency light roof radiant barrier additional ceiling and wall insulation double-pane, low-e windows external motorized shading and solar tubes a 16 SEER/9.75 HSPF heat pump improved ducts a whole-house fan a heat pump water heater (HPWH) integrated collector storage solar water heater (ICS SWH) and 3.2 kW of PV. In addition, the home was air sealed to reduce infiltration. Researchers from the National Renewable Energy Laboratory (NREL) performed short-term tests on the major systems installed as part of the retrofit to ensure that they were performing as expected. The systems evaluated included the space conditioning heat pump, the air handler and ducts, the HPWH, the ICS SWH, and the PV array. Some ducts were untwisted after testing revealed that two rooms were not getting sufficient airflow. Afterwards, all systems were performing as expected. In addition to testing to confirm adequate performance of all new systems, NREL was given the opportunity to use the Greenbuilt house as a laboratory house for a year. The space conditioning system and home water systems were subjected to a series of tests to determine optimal control strategies for lowering energy consumption and reducing peak (4:00-7:00 p.m.) energy consumption during the summer. The different cooling strategies considered included two different precooling schedules, drawing the external shades during the day and using the whole-house fan at night, and combinations of those. The most effective strategy for reducing overall energy consumption was the use of external shades, which cut the daily cooling load by 34% and reduced the energy use during peak hours by 40%. The different precooling strategies eliminated the peak load entirely but actually increased daily cooling energy use. The use of shades and the advanced precooling strategy increased the daily energy use by 5% but eliminated all peak use and maintained a comfortable home. These results were verified over the entire summer using an Energy Plus model of the home. The hot water system was tested in two configurations: the HPWH alone and the ICS solar water heater paired with the HPWH. Six hot water draw profiles, varying in terms of daily hot water volume, time of day for hot water use, and the duration of the draws, were imposed on the hot water system to test their effects on performance. When operating alone in the summer, the HPWH operated with a COP around 2.2, except for a draw that used a quarter of the averaged daily hot water usage, which had an average COP of 1.6. The combination of ICS and HPWH resulted in larger COPs, but also more variability depending on the draw profile. The standard, hourly draw profile produced the highest COP of 6.4. The quarter volume draw profile had the lowest COP of 2.8 for the combined system. Relative to a standard electric water heater, the HPWH operating alone reduced the peak load by 56% and the combined ICS and HPWH system completely eliminated the peak load.

air sealing↗

In-tank recirculating arsenic treatment system

A low-cost, water treatment system and method for reducing arsenic contamination in small community water storage tanks. Arsenic is removed by using a submersible pump, sitting at the bottom of the tank, which continuously recirculates (at a low flow rate) arsenic-contaminated water through an attached and enclosed filter bed containing arsenic-sorbing media. The pump and treatment column can be either placed inside the tank (In-Tank) by manually-lowering through an access hole, or attached to the outside of the tank (Out-of-Tank), for easy replacement of the sorption media.

42 ENGINEERING↗

Impact of Charge Degradation on the Life Cycle Climate Performance of a Residential Air-Conditioning System

Vapor compression systems continuously leak a small fraction of their refrigerant charge to the environment, whether during operation or servicing. As a result of the slow leak rate occurring during operation, the refrigerant charge decreases until the system is serviced and recharged. This charge degradation, after a certain limit, begins to have a detrimental effect on system capacity, energy consumption, and coefficient of performance (COP). This paper presents a literature review and a summary of previous experimental work on the effect of undercharging or charge degradation of different vapor compression systems, especially those without a receiver. These systems include residential air conditioning and heat pump systems utilizing different components and refrigerants, and water chiller systems. Most of these studies show similar trends for the effect of charge degradation on system performance. However, it is found that although much experimental work exists on the effect of charge degradation on system performance, no correlation or comparison between charge degradation and system performance yet exists. Thus, based on the literature review, three different correlations that characterize the effect of charge on system capacity and energy consumption are developed for different systems as follows: one for air-conditioning systems, one for vapor compression water-to-water chiller systems, and one for heat pumps. These correlations can be implemented in vapor compression cycle simulation tools to obtain a better prediction of the system performance throughout its lifetime. In this paper, these correlations are implemented in an open source tool for life cycle climate performance (LCCP) based design of vapor compression systems. The LCCP of a residential air-source heat pump is evaluated using the tool and the effect of charge degradation on the results is studied. The heat pump is simulated using a validated component-based vapor compression system model and the LCCP results obtained using the three charge degradation correlations are compared.

Air Conditioning↗

Resilience-Motivated Distribution System Restoration Considering Electricity-Water-Gas Interdependency

A major outage in the electricity distribution system may affect the operation of water and natural gas supply systems, leading to an interruption of multiple services to critical customers. Therefore, enhancing resilience of critical infrastructures requires joint efforts of multiple sectors. In this paper, a distribution system service restoration method considering the electricity-water-gas interdependency is proposed. The objective is maximizing the supply of electricity, water, and gas to critical customers after an extreme event. The operational constraints of electricity, water, and natural gas networks are considered. Additionally, the characteristics of electricity-driven coupling components, including water pumps and gas compressors, are also modeled. Relaxation techniques are applied to non convex constraints posed by physical laws of those networks. Consequently, the restoration problem is formulated as a mixed-integer second-order cone program, which can readily be solved by the off-the-shelf solvers. The proposed method is validated by numerical simulations on an electricity-water-gas integrated system, developed based on benchmark models of the subsystems. The results indicate that considering the interdependency refines the allocation of limited generation resources and demonstrate the exactness of the proposed convex relaxation

24 POWER TRANSMISSION AND DISTRIBUTION↗

Aquatic biofilms and their responses to disinfection and invading species

The control of microbial contamination is a primary concern in the development of a water reclamation system for long-duration manned space flights. This paper describes bench-scale experiments, using both static and recycling water systems, investigating the interaction of bacterial species in the development of a biofilm and their response to the introduction of a disinfectant or of additional species. The results showed that iodine concentrations as high as 15 to 20 mg/l I2 are necessary to completely disinfect a stable biofilm. When S. aueus and E. coli were introduced into a system containing natural mixed culture biofilms, their colonization in the biofilms increased their survival time, from 3 to 5 days as unattached cells to over 60 days when protected in the biofilms. While iodine concentrations of 0.5 to 1 mg/l were enough to eliminate these organisms from the bulk water, concentrations higher than 4.0 mg/l were necessary to completely eliminate these organisms from the biofilm.

Smithers, G. A.↗

Synthetic Biologic Membrane

The International Space Station (ISS) is a test bed for the technologies that will be used to travel to Mars and beyond. The lessons learned from operating the ISS provide valuable direction to future research and technology development programs. One of the most critical and complicated subsystems on ISS is the life support system. The life support system keeps the crew alive by recycling both air and water. The ISS water recycling system has been operating since 2009 and one of the main lessons learned is that reliability is a key technology performance metric. In the long run reliability is a key cost driver and is a critical factor in insuring crew safety. For long duration missions such as the exploration of Mars, where resupply of spare parts from Earth is difficult if not impossible, reliability is even more important. This presentation will cover research into improving the reliability of ISS systems. It will discuss research into the development of a biomimetic membrane materials that provides self-regeneration capabilities for water recycling systems. It will also cover research into past failures of the ISS water recycling system caused by astronaut bone loss and the build-up of trace contaminates in the cabin.

Biology↗

Space Station Freedom environmental database system (FEDS) for MSFC testing

The Water Recovery Test (WRT) at Marshall Space Flight Center (MSFC) is the first demonstration of integrated water recovery systems for potable and hygiene water reuse as envisioned for Space Station Freedom (SSF). In order to satisfy the safety and health requirements placed on the SSF program and facilitate test data assessment, an extensive laboratory analysis database was established to provide a central archive and data retrieval function. The database is required to store analysis results for physical, chemical, and microbial parameters measured from water, air and surface samples collected at various locations throughout the test facility. The Oracle Relational Database Management System (RDBMS) was utilized to implement a secured on-line information system with the ECLSS WRT program as the foundation for this system. The database is supported on a VAX/VMS 8810 series mainframe and is accessible from the Marshall Information Network System (MINS). This paper summarizes the database requirements, system design, interfaces, and future enhancements.

Story, Gail S.↗

System and process for efficient separation of biocrudes and water in a hydrothermal liquefaction system

A system and process are described for clean separation of biocrudes and water by-products from hydrothermal liquefaction (HTL) product mixtures of organic and biomass-containing feedstocks at elevated temperatures and pressures. Inorganic compound solids are removed prior to separation of biocrude and water by-product fractions to minimize formation of emulsions that impede separation. Separation may be performed at higher temperatures that reduce heat loss and need to cool product mixtures to ambient. The present invention thus achieves separation efficiencies not achieved in conventional HTL processing.

09 BIOMASS FUELS↗

Phase III integrated water recovery testing at MSFC - Design, plans, and protocols

A series of tests is being conducted at the NASA Marshall Space Flight Center (MSFC) to evaluate the performance of a closed-loop water recovery system. Testing will be conducted at various levels of integration and loop-closure, culminating in complete closure of the water system with man-in-the-loop. This paper summarizes the test goals and objectives as well as the system design, plans, and protocols which have been established.

Bagdigian, Robert M.↗

Medium-resolution Autonomous in situ Gamma Detection System for Marine and Coastal Waters

We are developing a medium-resolution autonomous in situ gamma detection system for marine and coastal waters. The system is designed to extract and preconcentrate isotopes of interest from natural waters prior to detection in order to eliminate signal attenuation of the gamma rays traveling through water and lower the overall background due to the presence of naturally occurring radioactive isotopes (40K and U/Th series radionuclides). Filtration is used to preconcentrate target isotopes residing on suspended particles, while chemosorption is employed to preferentially extract truly dissolved components from the water column. A variety of commercial and in-house nano-porus chemosorbents have been selected, procured or produced, and tested. Used filter and chemosorbent media are counted autonomously using two LaBr3 detectors in a near 4-pi configuration around the samples. A compact digital pulse processing system developed in-house and capable of running in coincidence mode is used to process the signal from the detectors to a small on-board computer. The entire system is extremely compact (9” dia. x 30” len.) and platform independent, but designed for initial deployment on a research buoy.

Gamma ray spectrometry↗

Development of an Adsorption System for the Trash Compaction Processing System designed for operation in the International Space Station Express Rack

A water recovery system that utilizes adsorption to work with the Trash Compaction Processing System, formerly known as the Heat Melt Compactor, is being designed at NASA Ames Research Center as an option to current state of the art micro-gravity water management systems and contaminant control systems used in space. The adsorption system will be used in conjunction with the International Space Station Vacuum Exhaust system to avoid both the complexities of gas liquid phase separation in micro-gravity and venting of Trash Compaction Processing System effluents to the spacecraft cabin. The adsorption system will allow the water and gaseous effluents generated during the Trash Compaction System operation to be removed in a matter that meets the Vacuum Exhaust System venting rate requirements. The Trash Compaction Processing System is planned to fly as a Technology Demonstration on the International Space Station in the space station EXPRESS Rack facility. This paper describes the trade space that the adsorption system must operate in using the EXPRESS Rack facilities resources including the use of the Space Station Vacuum Exhaust System. Also described in this paper are design solutions to allow the adsorption system to function within the Express Rack and Vacuum Exhaust System Parameters.

Heat Melt Compactor↗

The Inhibition of Pb(IV) Oxide Formation in Chlorinated Water by Orthophosphate

Historically, understanding lead solubility and its control in drinking water has been based on Pb(II) chemistry. Unfortunately, there is very little information available regarding the nature of Pb(IV) oxides in finished drinking water and water distribution systems, and the conditions under which they persist. The objective of this research was to explore the impact of orthophosphate on the realistic pathways that lead to the formation of Pb(IV) oxides in chlorinated water. The results of XRD and XANES analysis showed that, in the absence of orthophosphate (DIC = 10 mg C/L, 24 C, pH 7.75-8.1, 3 mg Cl{sub 2}/L goal), Pb(IV) oxides formed with time following a transformation from the Pb(II) mineral hydrocerussite. Under the same experimental conditions, orthophosphate dosing inhibited the formation of Pb(IV) oxides. The Pb(II) mineral hydroxypyromorphite, Pb{sub 5}(PO{sub 4}){sub 3}OH, was the only mineral phase identified during the entire study of over 600 days, although the presence of some chloropyromorphite, Pb{sub 5}(PO{sub 4}){sub 3}Cl, could not be ruled out. The conclusions were further supported by SEM, TEM, and XANES analysis of lead colloids, and lead precipitation experiments conducted in the absence of free chlorine. The findings provide an important explanation for the absence of Pb(IV) oxides in some water systems that have used, or currently use, orthophosphate for corrosion control when otherwise, based on disinfection practices and water quality, its presence would be anticipated, as well as why the conversion from free chlorine to chloramines was not observed to increase lead release.

54 ENVIRONMENTAL SCIENCES↗

Advancing uncertainty characterization for understanding projected water scarcity in multi-sector, multi-actor river basins across scales.

Invited Talk at AGU Fall Meeting 2023 Modeling how human institutions and infrastructure interact with the water cycle is essential to better understand the vulnerability, and resilience of water resources systems from the local to the global scale. This is especially true when investigating multi-sector, multi-actor responses to the effects of long-term changes and short-term shocks. It is also well recognized that uncertainty present throughout the modeling cycle (e.g., in data, functional relations, and model coupling approaches) limits our ability to trace the interactive dynamics of human-water systems, as well as to quantify their implications for management and planning. Systems with large numbers of diverse stakeholders further compound this challenge, as uncertain drivers and complex dynamics might have very disparate effects on water users. The work presented is conducted through the Integrated Multisector Multiscale Modeling (IM3) Science Focus Area, which explores how human and natural systems co-evolve in response to change. Through this multi-year effort, we have developed exploratory modeling methods to better characterize how the uncertain human and natural drivers of water scarcity yield consequential vulnerabilities in institutionally complex, multi-sectoral systems. This talk will specifically present on a series of uncertainty characterization experiments performed in the Upper Colorado River Basin, a sub-basin of the Colorado with thousands of water users. These complementary and systematic experiments are aimed at understanding: How are various uncertain stressors (e.g., climate change, demand growth) affecting the diverse water users of this basin in terms of water shortage? What are the key drivers of this shortage for each user? Methods and results from this work are used to address additional questions on the ability of adaptation to modulate the effects of these uncertain drivers, and on their compounding effects across spatial scales and through sectoral interactions.

Hadjimichael, Antonia↗