Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

DESIGN STUDY FOR A LOW-ENRICHED URANIUM CORE FOR THE HIGH FLUX ISOTOPE REACTOR, ANNUAL REPORT FOR FY 2010

This report documents progress made during FY 2010 in studies of converting the High Flux Isotope Reactor (HFIR) from high enriched uranium (HEU) fuel to low enriched uranium (LEU) fuel. Conversion from HEU to LEU will require a change in fuel form from uranium oxide to a uranium-molybdenum alloy. With axial and radial grading of the fuel foil and an increase in reactor power to 100 MW, calculations indicate that the HFIR can be operated with LEU fuel with no degradation in performance to users from the current level. Studies are reported of support to a thermal hydraulic test loop design, the implementation of finite element, thermal hydraulic analysis capability, and infrastructure tasks at HFIR to upgrade the facility for operation at 100 MW. A discussion of difficulties with preparing a fuel specification for the uranium-molybdenum alloy is provided. Continuing development in the definition of the fuel fabrication process is described.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Report on the FY18 Uniaxial Material Model Testing and Key Feature Test Articles Testing of Grade 91

This report summarizes the results from experiments performed in FY18 on Gr. 91 steel (heat 30176). The testing of Gr. 91 has technical significance because, currently, it is the only approved material for Class A construction in ASME Section III Division 5 that is strongly cyclic softening. The focus of this investigation is the effect of pre-cyclic loading history on the responses of Gr. 91 under key feature testing with Simplified Model Test (SMT) creep fatigue and two-bar thermal ratchet loading. For the pre-softened SMT, the SMT life reduction ratio was found to be approximately the same as the pre-softening fatigue damage ratio. The pre-softening also affected the ratchet behavior for the SMT specimens. Under the same two-bar thermal ratchet test conditions, the pre-softened specimens showed faster ratchet ting rates or larger accumulated strains than those without pre-softening history. In addition, results from previous uniaxial mechanical tests in support of the viscoplastic material model development for Gr. 91 are summarized, and the new results from thermomechanical testing at high temperature range are reported.

36 MATERIALS SCIENCE↗

Understanding and Overcoming Water-induced Interfacial Degradation in Si Modules (Final Technical Report)

Moisture ingress is an established issue for photovoltaic module durability. Durability studies probing moisture effects typically evaluate performance losses at the module level, attributing global power losses to the overall humidity condition of the test environment while leaving local module behavior unknown. This project successfully develops an in situ short-wave infrared probe of moisture content in PV modules with demonstrated detection limits better than 100 ppm in EVA-encapsulated Al-BSF and PERC architectures (66 µg/cm3) and applicability across the range of terrestrial conditions. Combining this optical moisture quantification method (water reflectometry detection, WaRD) with peel testing of interfaces, biased photoluminescence imaging of performance, and first principles computation, we correlate module moisture content and cell performance over the course of accelerated damp heat tests. By performing multi-level humidity and thermal accelerated testing over thousands of hours (0, 65 and 85% RH and 25, 65, and 85°C), we are able to attribute effects of individual environmental stresses and the dependence on module architecture. Using first-principles computational chemistry, we find that the decomposition of EVA to acetic acid (Norrish II) is thermodynamically preferred over a pathway to acetaldehyde (Norrish I), elucidating the underlying chemistry of encapsulant degradation. We also find it is likely that water segregates to the stable interfaces of the cell, especially the SiNx/EVA interface. We find that moisture is strongly correlated with reduction in adhesion at the interfaces of the cells, particularly at Ag fingers. We show uniquely that the peel strength required to delaminate the encapsulant from the front of the cell depends not only on the exposure to a high heat and humid environment, but also to the moisture content during the mechanical testing, indicating an important interaction between when mechanical stresses are faced in terms of the moisture content of the module and its durability. We find that the background sheet resistance (that is, the sheet resistance rise not attributable to finger interruptions or cracks) is substantially higher in the backsheet mini-modules vs glass-glass packages when humidity and temperature are faced. This increase in power loss due to the background resistance increase over time in damp heat in glass-backsheet modules resulted in ~3-4% larger decrease in relative PCE compared to glass-glass modules. In glass-backsheet modules, the effect of the moisture dose alone is comparable or greater than that of the combined temperature and water term, suggesting that glass-backsheet modules are overall more susceptible to moisture induced performance loss. Finally, we show that thin film PV modules are amenable to WaRD measurement, based on the ability to detect moisture in POE encapsulants or in the cell stack itself. The ease of WaRD measurement and its few requirements on the bill of materials should enable broad applicability of this technique for studying the effects of moisture in PV.

14 SOLAR ENERGY↗

Some contamination problems in the European TD satellite

Materials were selected for the European TD satellite with a view to avoiding contamination of its stellar ultraviolet telescopes. Materiels were selected using the micro-VCM technique, and some typical cases of materials evaluation are described. The cleanliness of the satellite was monitored during integration and test phases, and in particular during long duration thermal vacuum tests.

Dauphin, J.↗

Shuttle active thermal control system development testing. Volume 2: Modular radiator system tests

Tests were designed to investigate the validity of the "modular" approach to space radiator system design for space shuttle and future applications by gathering performance data on various systems comprised of different numbers of identical panels, subject to nominal and extreme heat loads and environments. Both one-sided and two-sided radiation was tested, and engineering data was gathered on simulated low a/e coatings and system response to changes in outlet temperature control point. The results of the testing showed system stability throughout nominal orbital transients, unrealistically skewed environments, freeze-thaw transients, and rapid changes in outlet temperature control point. Various alternative panel plumbing arrangements were tested with no significant changes in performance being observed. With the MRS panels arranged to represent the shuttle baseline system, a maximum heat rejection of 76,600 Btu/hr was obtained in segmented tests under the expected worst case design environments. Testing of an alternate smaller two-sided radiation configuration yielded a maximum heat rejection of 52,931 Btu/hr under the maximum design environments.

Scheps, P. B.↗

Shuttle active thermal control system development testing. Volume 5: Integrated radiator/expendable cooling system tests

Tests were conducted to gather data on a space shuttle active control system (ATCS) incorporating both radiators and an expendable cooling device to provide vehicle heat removal. Two systems were tested and design information was provided for both nominal and limit conditions. The tests verified the concept that an integrated radiator/expendable cooling system can adequately maintain desired water quantities while responding to variations in heat loads and environments. In addition, the need for duct heating was demonstrated, while exhaust nozzle heating was also shown to be unnecessary.

Scheps, P. B.↗

Shuttle active thermal control system development testing. Volume 6: Water ejector plume tests

Results are given of vacuum testing of nozzles designed to eject water vapor away from the space shuttle to prevent contamination of the spacecraft surfaces and payload. The water vapor is generated by an active cooling system which evaporates excess fuel cell water to supplement a modular radiator system (MRS). The complete heat rejection system including the MRS, flash evaporator or sublimator and nozzle were first tested to demonstrate the system operational characteristics. The plume tests were performed in two phases and the objectives of this test series were: (1) to determine the effectiveness of a supersonic nozzle and a plugged nozzle in minimizing impingement upon the spacecraft of water vapor exhausted by an active device (flash evaporator or sublimator); and (2) to obtain basic data on the flow fields of exhaust plumes generated by these active devices, both with and without nozzles installed.

Mcginnis, F. K.↗

Techniques for aerothermal tests of large, flightweight thermal protection panels in a Mach 7 wind tunnel

Recently developed experimental techniques permit evaluating thermal performance and structural integrity of full-scale panel concepts applicable to reentry and hypersonic vehicles in the Langley 8-foot high-performance structures tunnel. Rate and magnitude of surface heating and differential-pressure loading are independently controlled. Realistic temperature distributions are radiantly preheated into the panel prior to aerodynamic heating, and stream conditions are preselected to sustain the preheat surface heating input during aerodynamic exposure. During tunnel start and shutdown, panels are shielded outside the stream from potentially damaging transient acoustics and buffeting and are then rapidly inserted into the hypersonic flow. Infrared radiometry provides detailed surveys of surface temperatures.

Deveikis, W. D.↗

Vibroacoustic testing of Space Shuttle thermal protection system panels

The modes and acoustic responses of two panels representing Space Shuttle thermal protection panels were investigated. The panels consisted of flat aluminum sheet stiffened longitudinally with hat-section stringers and corrugated supporting panels representing Shuttle ring frame bulkheads. In addition, one panel had 24 tiles of LI900 silica thermal insulation material and a strain isolator pad bonded to the face sheet. Both panels were found to have approximately eight modal frequencies in the 60 to 500 Hz range, where Shuttle acoustic loads are expected to be high. The strain response to a progressive acoustic wave representing a Shuttle spectrum was characterized by the occurrence of larger strains in the direction normal to the stringers than in the direction parallel to the stringers; three modes in the 100 to 400 Hz range contributed significantly to the strain response.

Rucker, C. E.↗

Hot-air flat-plate solar collector-design package

Report contains design data, performance specifications, and drawings for hot-air flat-plate solar-energy collector. Evaluation consists of tests on thermal performance time constance, and incidence angle modifier test. Results are presented in table and graph form and are analyzed in detail.

Source record↗

Keynote address

The Space Shuttle test program is described. Consideration is given to thermal vacuum testing, static testing, ground vibration testing, high temperature testing, propulsion system testing, etc. Emphasis is placed on the Shuttle test philosophy and how it differs from that of past programs.

Yardley, J. F.↗

Design and test of a prototype thermal bus evaporator reservoir aboard the KC-135 0-g aircraft

The Thermal Bus Zero-G Reservoir Demonstration Experiment (RDE) has currently undergone two flights on the NASA-JSC KC-135 Reduced Gravity Aircraft. The objective of the experiment, which uses a smaller version of the evaporator reservoirs being designed for the Prototype Thermal Bus for Space Station, is to demonstrate proper 0-g operation of the reservoir in terms of fluid positioning, draining, and filling. The KC-135 was chosen to provide a cost-effective and timely evaluation of 0-g design issues that would be difficult to predict analytically. A total of fifty 0-g parabolas have been flown, each providing approximately 25-30 seconds of 0-g time. While problems have been encountered, the experiment has provided valuable design data on the 0-g operation of the reservoir. This paper documents the design of the experiment; the results of both flights, based on the high-speed movies taken during the flight and the visual observations of the experimenters; and the design modifications made as a result of the first flight and planned as a result of the second flight.

Brown, Richard F.↗

Fourteenth Space Simulation Conference: Testing for a Permanent Presence in Space

The Institute of Environmental Sciences Fourteenth Space Simulation Conference, Testing for a Permanent Presence in Space, provided participants a forum to acquire and exchange information on the state-of-the-art in space simulation, test technology, thermal simulation, and protection, contamination, and techniques of test measurements.

Stecher, Joseph L., III↗