Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Testing and Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Fatigue crack growth rates of X100 steel welds in high pressure hydrogen gas considering residual stress effects

Fatigue crack growth rate (FCGR) data were measured in high pressure hydrogen gas versus stress intensity factor range (ΔK) in specimens removed from a X100 welded steel pipe. Three distinct regions of the pipe weld were examined: base metal, weld fusion zone, and heat affected zone. Tests were performed at a load ratio (R) of 0.5, frequency of 1 Hz, and at a hydrogen gas pressure of 21 MPa. Tests were also performed in air at 10 Hz as a reference. Fatigue crack growth rates were observed to be over an order of magnitude higher for tests performed in hydrogen compared to the rates from tests in air. Residual stress measurements were collected on identical specimens cut from the base metal, weld, and heat affected zone to account for their influence on measured FCGR data. The slitting method provided residual stress and residual stress intensity factor (K res ), the effect of which was removed from the FCGR data using K norm in order to provide a more direct comparison of crack growth resistance of the base metal, weld and heat affected zone. Prior to accounting for residual stress, FCGR in hydrogen gas appeared to be highest in the weld fusion zone. Furthermore, after accounting for residual stress effects, the weld fusion zone FCGR data converged to the base metal FCGR data, which underscores the importance of accounting for residual stress effects when assessing fatigue performance.

42 ENGINEERING↗

Testing of ENDF71x: A new ACE-formatted neutron data library based on ENDF/B-VII.1

The ENDF71x library [1] is the most thoroughly tested set of ACE-format data tables ever released by the Nuclear Data Team at Los Alamos National Laboratory (LANL). It is based on ENDF/B-VII. 1, the most recently released set of evaluated nuclear data files produced by the US Cross Section Evaluation Working Group (CSEWG). A variety of techniques were used to test and verify the ENDF7 1x library before its public release. These include the use of automated checking codes written by members of the Nuclear Data Team, visual inspections of key neutron data, MCNP6 calculations designed to test data for every included combination of isotope and temperature as comprehensively as possible, and direct comparisons between ENDF71x and previous ACE library releases. Visual inspection of some of the most important neutron data revealed energy balance problems and unphysical discontinuities in the cross sections for some nuclides. Doppler broadening of the total cross sections with increasing temperature was found to be qualitatively correct. Test calculations performed using MCNP prompted two modifications to the MCNP6 source code and also exposed bad secondary neutron yields for {sup 231,233}Pa that are present in both ENDF/B-VII.1 and ENDF/B-VII.0. A comparison of ENDF71x with its predecessor ACE library, ENDF70, showed that dramatic changes have been made in the neutron cross section data for a number of isotopes between ENDF/B-VII.0 and ENDF/B-VII.1. Based on the results of these verification tests and the validation tests performed by Kahler, et al. [2], the ENDF71x library is recommended for use in all Monte Carlo applications. (authors)

97 MATHEMATICS AND COMPUTING↗

Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters

This paper explores the laboratory performance of five integrated Heat Pump Water Heaters (HPWHs) across a wide range of operating conditions representative of U.S. climate regions. HPWHs are expected to provide significant energy savings in certain climate zones when compared to typical electric resistance water heaters. Results show that this technology is a viable option in most climates, but differences in control schemes and design features impact the performance of the units tested. Tests were conducted to map heat pump performance across the operating range and to determine the logic used to control the heat pump and the backup electric heaters. Other tests performed include two unique draw profile tests, reduced air flow performance tests and the standard DOE rating tests. The results from all these tests are presented here for all five units tested. The results of these tests will be used to improve the EnergyPlus heat pump water heater for use in BEopt™ whole-house building simulations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Testing ΛCDM at the lowest redshifts with SN Ia and galaxy velocities

Peculiar velocities of objects in the nearby universe are correlated due to the gravitational pull of large-scale structure. By measuring these velocities, we have a unique opportunity to test the cosmological model at the lowest redshifts. We perform this test, using current data to constrain the amplitude of the "signal" covariance matrix describing the velocities and their correlations. We consider a new, well-calibrated "Supercal" set of low-redshift SNe Ia as well as a set of distances derived from the fundamental plane relation of 6dFGS galaxies. Here, analyzing the SN and galaxy data separately, both results are consistent with the peculiar velocity signal of our fiducial ΛCDM model, ruling out the noise-only model with zero peculiar velocities at greater than 7σ (SNe) and 8σ (galaxies). When the two data sets are combined appropriately, the precision of the test increases slightly, resulting in a constraint on the signal amplitude of A = 1.05 -0.21 +0.25 where A = 1 corresponds to our fiducial model. Equivalently, we report an 11% measurement of the product of the growth rate and amplitude of mass fluctuations evaluated at z eff = 0.02, f σ 8 = 0.428 -0.045 +0.048 , valid for our fiducial ΛCDM model. Here, we explore the robustness of the results to a number of conceivable variations in the analysis and find that individual variations shift the preferred signal amplitude by less than ~0.5σ. We briefly discuss our Supercal SN Ia results in comparison with our previous results using the JLA compilation.

79 ASTRONOMY AND ASTROPHYSICS↗

Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters

This paper explores the laboratory performance of five integrated Heat Pump Water Heaters (HPWHs) across a wide range of operating conditions representative of US climate regions. HPWHs are expected to provide significant energy savings in certain climate zones when compared to typical electric resistance water heaters. Results show that this technology is a viable option in most climates, but differences in control schemes and design features impact the performance of the units tested. Tests were conducted to map heat pump performance across the operating range and to determine the logic used to control the heat pump and the backup electric heaters. Other tests performed include two unique draw profile tests, reduced air flow performance tests and the standard DOE rating tests. The results from all these tests are presented here for all five units tested. The results of these tests will be used to improve the EnergyPlus heat pump water heater for use in BEopt(tm) whole-house building simulations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Steady-State Comparison of GS-IHP Field Data to Modeled Performance

Field tests were conducted over the winter and summer of 2011 on a prototype (ground-source integrated heat pump (GS-IHP) in Oak Ridge, TN. The extensive field test data was filtered to provide a subset of near-steady-state operation data suitable for comparison to modeled steadystate performance. On-site power use characteristics of the compressor, blower, and pumps and other operational measurements were used to calibrate the system model. Comparisons were made for four modes of operation: space heating, dedicated water heating, space cooling, and combined space cooling and water heating. Analysis results suggest that the field unit was undercharged, especially in the combined space cooling and water heating mode. The fully calibrated model agreed on average to within 2% on capacity, power, and COP/EER for the space heating and cooling modes. Average differences were larger for the water heating modes, ranging from 3 to 11%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radiation-Hardened Circuitry Using Mask-Programmable Analog Arrays: Report 3

As the recent accident at Fukushima Daiichi so vividly demonstrated, telerobotic technologies capable of withstanding high radiation environments need to be readily available to enable operations, repair, and recovery under severe accident scenarios when human entry is extremely dangerous or not possible. Telerobotic technologies that enable remote operation in high dose rate environments have undergone revolutionary improvement over the past few decades. However, much of this technology cannot be employed in nuclear power environments because of the radiation sensitivity of the electronics and the organic insulator materials currently in use. This is a report of the activities involving Task 3 of the Nuclear Energy Enabling Technologies (NEET) 2 project Radiation Hardened Circuitry Using Mask-Programmable Analog Arrays. Evaluation of the performance of the system for both pre- and post-irradiation as well as operation at elevated temperature will be performed. Detailed performance of the system will be documented to ensure the design meets requirements prior to any extended evaluation. A suite of tests will be developed which will allow evaluation before and after irradiation and during temperature. Selection of the radiation exposure facilities will be determined in the early phase of the project. Radiation exposure will consist of total integrated dose (TID) up to 200 kRad or above with several intermediate doses during test. Dose rates will be in various ranges determined by the facility that will be used with a target of 30 kRad/hr. Many samples of the pre-commercial devices to be used will have been tested in previous projects to doses of at least 300 kRad and temperatures up to 125C. The complete systems will therefore be tested for performance at intermediate doses. Extended temperature testing will be performed up to the limit of the commercial sensors. The test suite performed at each test point will consist of operational testing of the three basic measurement functions plus electronic functional testing (power dissipation, voltage offset changes, noise variations, etc.). This suite will be developed as part of this task.

42 ENGINEERING↗

Distributed fiber sensing systems for 3D combustion temperature field monitoring in coal-fired boilers using optically generated acoustic waves (Final Report)

In this project, we have developed and tested three kinds of fiber optic sensing systems for real time monitoring of temperature variations within an industrial scale boiler furnace. The fiber optic sensing systems target spatial and temporal distributions of high temperature profiles in a boiler furnace in fossil power plants. The reconstructed temperature profile will provide critical input for the control mechanisms to optimize the combustion process. This temperature profile will address the essential problem for fossil power plants in achieving higher efficiency and fewer pollutant emissions. Acoustic pyrometer systems have been used to reconstruct temperature field of power plant boilers based on measuring TOF (times-of-flight) of sound waves along some straight paths in a 2D cross-section of the boiler. In this project, optically generated acoustic signals from a fiber optic sensing system have replaced the acoustic signals generated from an electrical transducer. A 3D reconstruction algorithm replaced the previous 2D model. In this project, three kinds of fiber optic sensing systems have been developed and tested. They are fiber optic sensing system I, fiber optic sensing system II (Distributed Sensing System I) and fiber optic sensing system III (Distributed Sensing System II). For fiber optic sensing system I, the fiber optic ultrasound generator acts as a signal generator. A microphone, hydrophone or other electronic devices serve as a signal receiver. In this system, there are one generator and one receiver. Distance test, water temperature test, air temperature test, air temperature reconstruction, and GE ISBF pilot test were performed by Fiber optic sensing system I. The fiber optic sensing system I successfully detected temperature in all these tests. We got 2D temperature reconstruction results by using the fiber optic sensing system I and it matched the reference data. The fiber optic sensing system I successfully survived in GE ISBF boiler environment (480 °F). For fiber optic sensing system II (Distributed Sensing System I), it is an all optical ultrasound system. The fiber optic ultrasound generator acts as a signal generator. Fiber Bragg Grating (FBG) and Fabry-Perot (FP) sensor act as a signal receiver. In this system, there is one generator and one receiver. Aluminum plate temperature test, furnace high temperature test, and GE ISBF pilot test were performed by the fiber optic sensing system II. Fiber optic sensing system II successfully detected the temperature in all these tests. The fiber optic sensing system II successfully survived at up to 700 °C furnace environment and 320 °C GE ISBF boiler environment. For fiber optic sensing system III (Distributed Sensing System II), it is also an all optical ultrasound system. The fiber optic ultrasound generator acts as a signal generator. Multiple FP fiber sensors act as signal receivers. In this system, there is one generator and three receivers. Three GE ISBF pilot tests were performed by fiber optic sensing system III. The fiber optic sensing system III survived in the cold flow tests in GE’s ISBF pilot test facility. However, we didn’t get high temperature data by using this system since the nanosecond laser issues. During the period of the project, test trials, data simulation and algorithm optimization was performed successfully. For real time temperature field construction, the sampling rate must be fast enough to capture the field variations. The technology of Code-division multiple access (CDMA) is well studied which could allow parallel multiplexing, even if signals overlap in time or frequencies. Moreover, it has been known that extending the length of signal significantly improves SNR. For acoustic signals, these multiplexing techniques have also been widely used, mainly for sonar and acoustic communications. The CDMA modulation technique has been proposed and studied to guarantee high network throughput, low channel access delay and low energy consumption. We have studied the temperature field reconstruction using Gaussian Radial Basis Functions (GRBF)-based approximation approach. Reconstruction of 3D temperature field using Neural Networks with measured TOF and known propagation paths is feasible. 2D and 3D temperature field reconstruction simulation results are achieved. The milestone status is shown in Table 1. We finished milestone 1-8 and milestone 10. For milestone 9, we did three pilot tests by using the fiber optic sensing system III (Distributed Sensing System II) at GE Power. However, due to the failure of the ns laser, we did not get the temperature results. We conducted some additional tasks that were not originally proposed: 1) We fabricated a fiber optic sensing system I and did a pilot test based on this system. 2) In the proposal, we proposed two pilot tests at GE Power. In reality, we finished at least seven pilot tests at GE Power. GE Power has made a lot of efforts for supporting the pilot tests. 3) We got a simulation results based on CDMA. In summary, most of the tasks have been accomplished. The outcome of this project removed a few barriers that hinder the achievement of the final product of the distributed sensing systems. With the successful accomplishment of this project, a prototype of the fiber optic sensing system can be fabricated to attract more interests from companies and other funding agencies.

47 OTHER INSTRUMENTATION↗

Multi-Column Xe/Kr Separation with AgZ-PAN and HZ-PAN

Previous multi-column xenon/krypton separation tests have demonstrated the capability of separating xenon from krypton in a mixed gas feed stream. The results of this initial testing with AgZ-PAN and HZ-PAN indicated that an excellent separation of xenon from krypton could be achieved. Building upon these initial results, a series of additional multi-column testing were performed in FY-16. The purpose of this testing was to scale up the sorbent beds, test a different composition of feed gas and attempt to improve the accuracy of the analysis of the individual capture columns’ compositions. Two Stirling coolers were installed in series to perform this testing. The use of the coolers instead of the cryostat provided two desired improvements, 1) removal of the large dilution due to the internal volume of the cryostat adsorption chamber, and 2) ability to increase the sorbent bed size for scale-up. The AgZ-PAN sorbent, due to its xenon selectivity, was loaded in the first column to capture the xenon while allowing the krypton to flow through and be routed to a second column containing the HZ-PAN for capture and analysis. The gases captured on both columns were sampled with evacuated sample bombs and subsequently analyzed via GC-MS for both krypton and xenon. The results of these tests can be used to develop the scope of future testing and analysis using this test bed for demonstrating the capture and separation of xenon and krypton using sorbents, for demonstrating desorption and regeneration of the sorbents, and for determining compositions of the desorbed gases. They indicate a need for future desorption studies in order to better quantify co-adsorbed species and final krypton purity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determination of the Impact of Glycolate on ARP and MCU Operations

Savannah River Remediation (SRR) is evaluating an alternate flowsheet for the Defense Waste Processing Facility (DWPF) using glycolic acid as a reductant. An important aspect of the development of the glycolic acid flowsheet is determining if glycolate has any detrimental downstream impacts. Testing was performed to determine if there is any impact to the strontium and actinide sorption by monosodium titanate (MST) and modified monosodium titanate (mMST) or if there is an impact to the cesium removal, phase separation, or coalescer performance at the Modular Caustic-Side Solvent Extraction Processing Unit (MCU). Sorption testing was performed using both MST and modified MST (mMST) in the presence of 5000 and 10,000 ppm (mass basis) glycolate. 10,000 ppm is the estimated bounding concentration expected in the DWPF recycle stream based on DWPF melter flammable gas model results. The presence of glycolate was found to slow the removal of Sr and Pu by MST, while increasing the removal rate of Np. Results indicate that the impact is a kinetic effect, and the overall capacity of the material is not affected. There was no measurable effect on U removal at either glycolate concentration. The slower removal rates for Sr and Pu at 5000 and 10,000 ppm glycolate could result in lower DF values for these sorbates in ARP based on the current (12 hours) and proposed (8 hours) contact times. For the highest glycolate concentration used in this study, the percentage of Sr removed at 6 hours of contact decreased by 1% and the percentage of Pu removed decreased by nearly 7%. The impact may prove insignificant if the concentration of glycolate that is returned to the tank farm is well below the concentrations tested in this study. The presence of glycolate also decreased the removal rates for all three sorbates (Sr, Pu, and Np) by mMST. Similar to MST, the results for mMST indicate that the impact is a kinetic effect, and the overall capacity of the material is not affected. The presence of glycolate did not change the lack of affinity of mMST for U. Pre-contacting the MST or mMST with glycolate did not have a significant effect on the performance of the materials when compared to tests having the same concentration of glycolate present in the simulant. These findings suggest that the glycolate is likely influencing removal by sorbate complexation and not by depositing onto or forming a film on the surface of the MST solids. Since the DF values are salt batch dependent, it is not possible to a priori quantify the impacts of glycolate on future processing campaigns. However, we recommend that the impacts of glycolate be evaluated during each salt batch qualification when a final processing concentration is defined, and recommendations can then be made on how to mitigate negative impacts, if needed. Impacts to the performance of the MST or mMST could be mitigated by increasing contact time or increasing sorbent concentrations. Testing was performed to determine if there is an impact to the cesium removal at Modular Caustic-Side Solvent Extraction Processing Unit (MCU). An Extraction-Scrub-Strip (ESS) test routine was used to simulate cesium removal at the MCU. For this, SRNL performed three ESS tests, using the same basic aqueous waste simulant and solvent. For one test, SRNL added 5000 ppm (mass basis) of glycolate and added 10,000 ppm of glycolate to a second test. A control test contained no glycolate. The results of all three tests were virtually identical for all the extraction, scrub and strip tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Study on Emulsification/Demulsification Behavior and Mechanism of Produced Liquid from Polymer Flooding on Alaska North Slope

Heavy oil reservoirs on Alaska North Slope (ANS) are unconsolidated and contain abundant clay minerals, where the first-ever field pilot is currently implemented to validate the use of polymer floods for heavy oil enhanced oil recovery (EOR). The polymer molecules and/or fine clay particles carried with the produced liquid could potentially affect the oil/water separation, which is one of the major concerns for field operators. This dissertation aims to investigate the emulsification behavior of produced liquid, understand the emulsifying mechanism, and seek an adaptive and cost-effective method to treat the produced liquid from polymer flooding. Emulsions were prepared by mechanically mixing the actual heavy oil and the produced water from the pilot site, of which the stability was investigated by bottle test method or multiple light scattering method. Drop size distribution and interfacial properties were measured via microscope and pendant drop technique to probe the stability mechanism further. Results showed that oil-continuous or water-continuous emulsion could be generated depending on the water cut, clay types, clay concentration, and polymer concentration. In the crude oil/water system, the increasing water cut triggered the phase inversion of oil-continuous emulsion to water-continuous emulsion, resulting in faster separation and lower emulsion stability. Whereas, clay particles, no matter added to the oil or water phase, resulted in an unfavorable phase inversion from the loose water-continuous emulsion to the tight oil-continuous emulsion as clay concentration increased. For all four types of clay except Ca-montmorillonite, clay particles added to water led to an earlier phase inversion and higher emulsion stability than that added to the oil. The dual function of polymer on emulsion stability was observed. On the one hand, both sheared and unsheared polymer tended to convert the oil-continuous emulsion formed in either crude oil/water system or complex crude oil/water/clay particle system to the water-continuous emulsion, acting as a weak demulsifier to accelerate the oil/water separation. On the other hand, the addition of polymer to the water-continuous emulsion could result in enhanced emulsion stability, which is primarily attributed to the increased viscosity of the continuous phase and the decreased drop size of the dispersed oil phase. Particularly, the sheared polymer had a weaker ability to stabilize the o/w emulsion than the unsheared polymer due to the lower viscosity of the sheared polymer solution resulting from the breakdown of the polymer macromolecules. As for the chemical demulsification tests, the performance of demulsifiers showed a complex dependency upon the water cut, the shearing intensity, demulsifier type and dosage, and the polymer concentration. A compound emulsion breaker, E12+E18, exhibited the most satisfactory demulsification performance despite the varied test conditions. For severe water-continuous emulsions that might require a multi-fold dosage of demulsifier, a less expensive electrolyte, KCl, was proposed to be used in combination with demulsifier E12+E18 to improve the demulsification performance. In the proposed demulsifier formula, the effectiveness of the commercial demulsifier relied on its destructive effect on the interfacial film, while the efficacy of KCl was mainly dependent on its viscosity reduction effect on the continuous phase. This dissertation illustrates that intermediate layer elimination and water clarification are the major challenges for produced liquid treatment from polymer flooding. It also provides practical and theoretical guidance in advance for the demulsification strategy of the produced liquid from the ongoing first-ever polymer flooding pilot on ANS.

Chang, Hongli↗

Kinetics of thermal de-chlorination of PVC under pyrolytic conditions

Highlights: Black-Right-Pointing-Pointer Several tests were performed in DTA/TGA for understanding the thermal behavior of pure PVC. Black-Right-Pointing-Pointer We did a kinetic model for the de-chlorination of PVC molecule. Black-Right-Pointing-Pointer A temperature of 340 Degree-Sign C was defined as the optimum temperature for breaking the bond of chlorine in the PVC molecule. Black-Right-Pointing-Pointer The experimental validation of this temperature, led to a removal rate of 99.9% chlorine. - Abstract: Although PVC-containing wastes are an important potential source of energy they are frequently disposed in landfill. In thermal treatment processes such as pyrolysis and gasification, the presence of poly(vinyl chloride) (PVC), a compound with 56.7% of chlorine, may cause problems concerned with environmental protection, as consequence of the formation of hydrochloric acid, chlorine gas and dioxins, as well as corrosion phenomena of the reactor/equipment materials. Thus, a possible solution may involve a previous removal of the chlorine from PVC containing waste through a pyrolysis process at low temperatures before the material being submitted to a subsequent thermal treatment, for energetic valorization. In this work, a kinetic model for the thermal decomposition of PVC has been developed, in view of its de-chlorination. DTA/TGA testing at different temperatures indicated a first order reaction and an activation energy of 133,800 J/mol. An almost completed de-chlorination reaction was obtained at 340 Degree-Sign C under an inert atmosphere. The resulted material is a C{sub n}H{sub n} type polymer with potential to be used in an energy recovery process. Validation test performed at laboratory scale indicate that the temperature of 340 Degree-Sign C enables the removal of {approx}99.9% of the chlorine present in PVC. The chloride can be fixed in the form of an aqueous solution of HCl or calcium chloride, driving to an alternative full process with environmental benefits and reduction of the costs associated to the PCV - containing materials/wastes management.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Report on RIA Relevant Modified Burst Testing of ATF Cladding Materials

The mechanical performance of accident-tolerant fuel (ATF) cladding candidates in light-water reactors (LWRs) must be similar to or better than that of current conventional nuclear fuel claddings to reduce dose to the public and ensure a that the core coolable geometry is maintained during a postulated reactivity-initiated accident (RIA) in light-water reactors (LWRs). During an RIA event, the rapid thermal expansion of nuclear fuel can deform the cladding once the fuel–cladding gap closes. In some cases, the pellet–cladding mechanical interaction (PCMI) can induce mechanical failure in ATF candidates. Thus, the mechanical response of ATF cladding must be investigated by mimicking the conditions of RIA and potentially performing Transient Reactor Test (TREAT) experiments to establish or verify the safety envelope. The work presented in this report investigated the failure behavior of as-received, hydrided, and chromium-coated (Cr-coated) Zircaloy-4 (Zry-4) cladding tube under strain-driven mechanical conditions, mimicking postulated RIA loading conditions. Mechanical testing was performed at 300°C via modified burst test (MBT) equipment with pulse width control previously developed under the Department of Energy’s (DOE’s) Advanced Fuel Campaign (AFC). The mechanical strains were determined using 2D digital image correlation (DIC) techniques. The base Zry-4 acquired by Cameco Inc. was in stress-relieved annealed (SRA) condition. Because of the observed large deformation of the cladding tubes, the failure strain definition was updated for the MBT, which can also be applied to other tube tests where significant bulging (out-of-plane deformation) is present. The failure strain was determined to be affected by the speed of the test or the RIA event. As the RIA-like event duration decreased from 75 to 15 ms, the failure strain decreased 5, 7 and 1% for as-received, hydrided, and Cr-coated specimens, respectively. Fractography on the Cr-coated specimens indicated the presence of two failure mechanisms: (i) crenulation at the outer surface of the coating due to the tensile tractional forces along with coatings grain microstructure and (ii) formation of critical defect at the coating/cladding interface that initiated coating rupture after severe plastic deformation of the Zry- 4 substrate. Based on the MBT results and fractography observations, performing mechanical property testing at high strain rates—in particular on Cr-coated tubes—and semi-integral TREAT experiments are required future efforts to ensure ATF cladding performance during transients. The testing recommended would also inform the development of long-term generalized cladding technologies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Benefits of colorectal cancer screening using fecal immunochemical testing with varying positivity thresholds by age and sex

Background Fecal immunochemical test (FIT) performance for colorectal cancer screening varies by age and sex, yet most FIT-based screening programs use uniform positivity thresholds. This study assessed the potential benefits of stratifying FIT thresholds based on age and sex. Methods We conducted a meta-analysis of FIT sensitivity and specificity at various positivity thresholds by age and sex. We then used these estimates in 2 microsimulation models of colorectal cancer and projected lifetime clinical outcomes, incremental costs, and quality-adjusted life-years (QALYs) gained from age- and sex-stratified FIT strategies. FIT thresholds ranged from 10 to 50 µg hemoglobin per gram of feces. Results For current uniform FIT screening (20 µg hemoglobin/gram of feces), models projected 85.67 to 122.15 QALYs gained at incremental costs of ‒$982 to $504 per 1000 individuals compared with no screening. At equivalent costs to current uniform screening, only 1 model found stratified FIT approaches cost-effective, yielding a marginal increase of 1.04 and 1.10 QALYs gained/1000 female and male individuals, respectively. At a willingness-to-pay threshold of $100 000/QALYs gained, both models found stratified FIT cutoffs to be the best strategy, with cutoffs being equal to or higher for males and lowest at older ages (70-75 years). Uniform strategies showed comparable effectiveness, falling within 1 quality-adjusted life-day per person of efficient strategies at up to $112 more per person. Results were sensitive to FIT test performance characteristics and 1-time setup costs. Conclusion Stratifying FIT thresholds by age and sex may be cost-effective compared to current screening. The gain in expected health benefits with stratified FIT screening, however, is likely small.

Harlass, Matthias↗

Progress Report on Modified Burst Testing and Alternative Test Methodologies

Performance of accident-tolerant fuel candidates must be assessed during the pellet-cladding mechanical interaction (PCMI) phase of a design-basis reactivity-initiated accident (RIA). Therefore, in this report, we describe Fiscal Year (FY) 2019 research activities on the development of separate-effects testing for ATF cladding candidate iron-chromium-aluminum (FeCrAl) tube specimens under loading conditions comparable to the PCMI. The first section of this report provides modified-burst test (MBT) results of unirradiated FeCrAl tubes at various pressurization-rates and an RIA-relevant temperature (275°C). The failure strain of FeCrAl was observed and calculated using a high-speed digital-image correlation (DIC) technique developed recently under the Department of Energy (DOE)’s Advanced Fuel Campaign (AFC). To overcome the complexities of performing MBT in a hot-cell environment on irradiated samples, a “plane-strain tension” (PST) test was proposed as an alternative methodology for PCMI testing. The relevance of the PST test as an alternative to MBT for irradiated specimens was explicated using the data available in the literature. The design of hot-cell compatible PST fixtures and a specific holder for PST hot-cell specimen machining were developed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High Strain Rate Testing of Welded DOP-26 Iridium

The iridium alloy DOP-26 is used to produce Clad Vent Set cups that protect the radioactive fuel in radioisotope thermoelectric generators (RTGs) which provide electric power for spacecraft and rovers. In a previous study, the tensile properties of DOP-26 were measured over a wide range of strain rates and temperatures and reported in ORNL/TM-2007/81. While that study established the properties of the base material, the fabrication of the heat sources requires welding, and the mechanical properties of welded DOP-26 have not been extensively characterized in the past. Therefore, this study was undertaken to determine the mechanical properties of DOP-26 specimens containing a transverse weld in the center of their gage sections. Tensile tests were performed at room temperature, 750, 900, and 1090°C and engineering strain rates of 1×10 -3 and 10 s -1 . Room temperature testing was performed in air, while testing at elevated temperatures was performed in a vacuum better than 1×10 -4 Torr. The welded specimens had a significantly higher yield stress, by up to a factor of ~2, than the non-welded base material. The yield stress did not depend on the strain rate except at 1090°C, where it was slightly higher for the faster strain rate. The ultimate tensile stress, on the other hand, was significantly higher for the faster strain rate at temperatures of 750°C and above. At 750°C and above, the specimens deformed at 1×10 -3 s -1 showed pronounced necking resulting sometimes in perfect chisel-edge fracture. The specimens deformed at 10 s -1 exhibited this fracture behavior only at the highest test temperature, 1090°C. Fracture occurred usually in the fusion zone of the weld and was, in most cases, primarily intergranular.

36 MATERIALS SCIENCE↗

Elucidating potential-induced degradation in bifacial PERC silicon photovoltaic modules

This paper elucidates the behavior and underlying mechanism of potential-induced degradation (PID) on the rear side of p-type monocrystalline silicon bifacial passivated emitter and rear cell (PERC) photovoltaic modules. At 50 degrees C, 30% relative humidity, and -1000 V bias to the solar cells with aluminium foil on the rear glass surface, the rear-side performance of bifacial PERC modules at standard testing conditions degraded dramatically after 40 hours with a 40.4%, 36.2%, and 7.2% loss in maximum power (Pmpp), short-circuit current (Isc), and open-circuit voltage (Voc), respectively. The front-side standard testing condition performance, on the other hand, showed less degradation; Pmpp, Isc, and Voc dropped by 12.0%, 5.2%, and 5.3%, respectively. However, negligible degradation was observed when the solar cells were positively biased. Based on I-V characteristics, electroluminescence, external quantum efficiency measurements, and the effective minority-carrier lifetime simulation, the efficiency loss is shown to be caused by the surface polarization effect; positive charges are attracted to the passivation/antireflection stack on the rear surface and reduce its field effect passivation performance. Extended PID testing to 100 hours showed an increase in device performances (relative to 40 hours) due to the formation of an inversion layer along the rear surface. In addition, replacing ethylene-vinyl acetate copolymer with polyolefin elastomer films significantly slows down the progression of PID, whereas a glass/transparent backsheet design effectively protects the rear side of bifacial PERC modules from PID. Furthermore, PID on the rear side of bifacial PERC modules is fully recoverable, and light greatly promotes recovery of the observed PID.

14 SOLAR ENERGY↗

FRACTIONAL CRYSALLIZATION LABORATORY TESTS WITH SIMULATED TANK WASTE

Results are presented for several simulated waste tests related to development of the fractional crystallization process. Product salt dissolution rates were measured to support pilot plant equipment design. Evaporation tests were performed to evaluate the effects of organics on slurry behavior and to determine optimum antifoam addition levels. A loss-of-power test was performed to support pilot plant accident scenario analysis. Envelope limit tests were done to address variations in feed composition.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗