Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “THERMALIZATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Rhodium self-powered neutron detector as a suitable on-line thermal neutron flux monitor in BNCT treatments

Purpose: A rhodium self-powered neutron detector (Rh SPND) has been specifically developed by the Comision Nacional de Energia Atomica (CNEA) of Argentina to measure locally and in real time thermal neutron fluxes in patients treated with boron neutron capture therapy (BNCT). In this work, the thermal and epithermal neutron response of the Rh SPND was evaluated by studying the detector response to two different reactor spectra. In addition, during clinical trials of the BNCT Project of the CNEA, on-line neutron flux measurements using the specially designed detector were assessed. Methods: The first calibration of the detector was done with the well-thermalized neutron spectrum of the CNEA RA-3 reactor thermal column. For this purpose, the reactor spectrum was approximated by a Maxwell-Boltzmann distribution in the thermal energy range. The second calibration was done at different positions along the central axis of a water-filled cylindrical phantom, placed in the mixed thermal-epithermal neutron beam of CNEA RA-6 reactor. In this latter case, the RA-6 neutron spectrum had been well characterized by both calculation and measurement, and it presented some marked differences with the ideal spectrum considered for SPND calibrations at RA-3. In addition, the RA-6 neutron spectrum varied with depth in the water phantom and thus the percentage of the epithermal contribution to the total neutron flux changed at each measurement location. Local (one point-position) and global (several points-positions) and thermal and mixed-field thermal neutron sensitivities were determined from these measurements. Thermal neutron flux was also measured during BNCT clinical trials within the irradiation fields incident on the patients. In order to achieve this, the detector was placed on patient's skin at dosimetric reference points for each one of the fields. System stability was adequate for this kind of measurement. Results: Local mixed-field thermal neutron sensitivities and global thermal and mixed-field thermal neutron sensitivities derived from measurements performed at the RA-6 were compared and no significant differences were found. Global RA-6-based thermal neutron sensitivity showed agreement with pure thermal neutron sensitivity measurements performed in the RA-3 spectrum. Additionally, the detector response proved nearly unchanged by differences in neutron spectra from real (RA-6 BNCT beam) and ideal (considered for calibration calculations at RA-3) neutron source descriptions. The results confirm that the special design of the Rh SPND can be considered as having a pure thermal response for neutron spectra with epithermal-to-thermal flux ratios up to 12%. In addition, the linear response of the detector to thermal flux allows the use of a mixed-field thermal neutron sensitivity of 1.95 {+-} 0.05 x 10{sup -21} A n{sup -1}{center_dot}cm{sup 2}{center_dot}s. This sensitivity can be used in spectra with up to 21% epithermal-to-thermal flux ratio without significant error due to epithermal neutron and gamma induced effects. The values of the measured fluxes in clinical applications had discrepancies with calculated results that were in the range of -25% to +30%, which shows the importance of a local on-line independent measurement as part of a treatment planning quality control system. Conclusions: The usefulness of the CNEA Rh SPND for the on-line local measurement of thermal neutron flux on BNCT patients has been demonstrated based on an appropriate neutron spectra calibration and clinical applications.

07 ISOTOPE AND RADIATION SOURCES↗

Thermally Conductive Backsheets (TCB) for Reduced Operating Temperatures

The performance of photovoltaic (PV) modules is primarily influenced by the plane of array (POA) irradiance and their operating temperature. The lower the module operating temperature, the higher is its performance. Increasing a module’s operating temperature reduces its power output due to an increase in the semiconductor’s intrinsic carrier density, leading to a reduction in the open-circuit voltage and, subsequently, reducing the maximum power point voltage. Reducing the operating temperature lowers the levelized cost of energy (LCOE) via increased energy production (i.e., more kilowatt hour over the life of the asset) and increased service lifetime (years in the field). The module operating temperature is dictated by the weather parameters and the thermal properties of module construction materials. The primary weather parameters influencing the PV module temperature are: the ambient temperature (directly related), irradiance (directly related), and wind speed (inversely related). The primary thermal properties of module construction materials influencing the PV module temperature are: the optical transmissivity and thermal conductivity of superstrate, the thermal conductivity of substrate, the thermal conductivity of encapsulant and the efficiency of the encapsulated solar cells. The primary goal of this study is to reduce the operating temperature of PV modules using thermally conductive backsheet (TCB) substrates developed by the industry. The temperature of PV modules installed in a large multi-MW plant can also be influenced by their physical locations in the plants due to the influence of wind direction. A thermal mapping of PV plants has also been investigated and presented in this study. The most commonly used PV backsheet material has been polyvinyl fluoride (DuPont trade name “Tedlar”)-based backsheet, which typically has three layers: Tedlar–polyethylene terephthalate (PET)–Tedlar (TPT). The primary goal of this project is to reduce the module operating temperature below the benchmark TPT backsheet temperature using newly developed TCBs by the industry. The overall approach of this project involves six focus areas: i) select and procure one TPT and thirteen promising TCBs available in the industry; ii) construct a large number of 1-cell and 9-cell modules using benchmark TPT and selected TCBs [all other construction materials are fixed and they are: glass superstrate, EVA encapsulant, mono-Si cell and junction box]; iii) to identify best performing TCBs, monitor the long-term field operating temperatures of the constructed modules which are installed in three climatic conditions (hot-low wind [Mesa, AZ], hot-high wind [Maricopa County, AZ] and temperate [Cumberland County, NC]; iv) to identify the most durable TCB, perform extended accelerated reliability testing of modules constructed with best three TCBs and benchmark TPT; v) to predict module temperature, develop physical and empirical thermal models with and without thermal properties of all construction materials in the modules, respectively; and vi) to determine the influence of wind speed and direction on the module operating temperature in a plant, and perform thermal mapping of PV modules in two large PV plants [Maricopa County, AZ and Cumberland County, NC]. The key achievements of this project are listed below: Backsheet selection: 14 backsheets were procured after an extensive literature and industry search. Finally, based on the thermal and other selection criteria, 1 TPT and 4 thermally conductive backsheets were selected for this project. Fabrication of mini modules: 50 one-cell modules were fabricated in year 1 for thermal performance evaluation. The module design was changed to nine-cell module at start of year 2 to mimic commercial design. 20 nine-cell modules were fabricated in year 2 for thermal performance evaluation. 28 four-cell modules were fabricated in year 3 for accelerated stress-testing. Thermal conductivity of backsheets: Year 1 TCBs showed at least 8% higher thermal conductivities than TPT. Year 2 and 3 TCBs showed at least 20% higher thermal conductivities than TPT. Installation of mini PV modules at three sites: 6 one-cell modules and 8 nine-cell modules were installed at AZ-1 site [Mesa, AZ]. 12 one-cell modules and 6 nine-cell modules were installed at each of two powerplants (AZ-2 [Maricopa County, AZ] and NC sites). Nominal operating cell temperatures (NOCT) of mini PV modules: NOCT of TCBs were observed to be lower than TPT with differences as high as 2°C. Comparison of thermal performance: The median operating temperature of one-cell modules was found to be reduced by 2°C by using TCB_A modules compared to TPT modules on several days in a month for few months in a year. The median temperature improvement of 4oC was achieved at several instances on a few days, but not all days, in a year using multiple TCBs compared to TPT. The final project milestone of achieving median temperature improvement of 5oC was achieved at several instances on a few days, but not all days, in a year using TCB_A compared to TPT. Empirical thermal model (without the need of construction material properties): Empirical thermal model for one-cell module was developed based on the input data of irradiance, wind speed and ambient temperatures. The primary input data differentiator for temperature differences between TPT and TCBs appears to be the irradiance level (solar gain). Accelerated durability testing: 20 four-cell modules using 4 backsheets (1 TPT and 3 TCBs) were exposed to Damp Heat 1000 hours (8 modules), UV/Thermal cycling (50 cycles)/Humidity freeze (10 cycles) test sequence (8 modules) and UV Weathering for qualification (8 modules). All the modules with four selected backsheets passed the stress tests per the retest guidelines of IEC 61215 standard for the backsheet change. Simplified comparative LCOE analysis: Using backsheet-specific power degradation levels in the accelerated tests (for TCB_A and TPT only), efficiency, service lifetime and assuming same cost for all backsheets, the LCOE of modules using TCB_A is determined to be lower than TPT. Due to lower operating temperature of TCB_A-based modules compared to TPT-based modules, the operating efficiency and service life of TCB_A-based modules are calculated to be higher than TPT-based modules. Temperature mapping of PV power plants: A distinct temperature difference (as high as 4°C) has been observed between the modules located in various parts of a single PV plant.

14 SOLAR ENERGY↗

Evaluating Heat Extraction Performance of Closed-Loop Geothermal Systems with Thermally Conductive Enhancements in Conduction-Only Reservoirs: Preprint

We investigated the impact of disc-shaped and linear thermal enhancements on performance of closed-loop geothermal systems using steady-state and transient COMSOL numerical simulations. Thermal enhancements refer to thermally conductive material introduced in the rocks surrounding a wellbore to compensate for the relatively low rock thermal conductivity and increase heat extraction. Materials proposed include composite cements with thermally conductive additives such as metals or graphite to obtain overall cement thermal conductivities of 10 to 100x the rock thermal conductivity. Our simulation approach was modeling a subsegment (e.g., 100 m long) of a wellbore with idealized (e.g., perfect disc-shaped) thermal enhancements, and we report results as relative increase in heat extraction with respect to systems without thermal enhancements. We did not evaluate technical feasibility or cost of installing thermal enhancements. Simulations indicate that for 5-mm thick disc-shaped thermal enhancements with 5-m radius, repeated every 1 m along the wellbore and with thermal conductivity of 100x the rock thermal conductivity, the thermal output increases roughly 20% with respect to a closed-loop system without thermal enhancements. For fishbone structure thermal enhancements, we estimate a roughly 7% increase in thermal output for 5-m long radially outward pipes with half the radius of the main wellbore, repeated every 2.5 m, with thermal conductivity of 100x the rock thermal conductivity.

advanced geothermal systems↗

Development and Validation of a High-Vacuum Thermal Conductivity Testbed for Aerospace Interface Materials

Thermal Interface Materials (TIMs) are critical components in spacecraft thermal management systems, where thermal performance is strongly influenced by vacuum conditions, interface contact resistance, and layered metallic joint behavior. However, manufacturer-reported thermal conductivity values are often derived under idealized conditions and may not accurately represent performance within operational aerospace applications. To address this limitation, the Testbed for Advanced Interface Materials in Vacuum (TAIMV) was developed as a modular vacuum-compatible thermal conductivity characterization platform capable of evaluating aerospace-relevant TIM configurations under both ambient and high-vacuum environments. The testbed was derived from the ASTM C1044-16 guarded hot plate methodology and incorporates interchangeable layers of stainless steel coupon geometries, independently controlled main and guard heaters, embedded resistance temperature detectors (RTDs), thermocouples, multi-layer insulation (MLI), and a temperature-controlled cold plate to characterize through-thickness thermal gradients across layered interfaces. In the current configuration, interface compression is limited to the nominal contact pressure generated by the experimental stack assembly. Initial experimental campaigns were conducted at ambient pressure and below 1×10-5 torr for vacuum cases using multiple interface materials including Braycote 601EF and Krytox-based greases across a range of thermal operating conditions. In parallel, a coupled numerical Python thermal model was developed to predict temperature distribution throughout the stack while accounting for conduction, radiation, and parasitic heat transfer pathways and effective interface resistance effects. Experimental measurements and numerical predictions showed consistent thermal trends across multiple operating conditions and environmental states. Results also revealed measurable differences between ambient and vacuum thermal behavior, demonstrating the importance of interface resistance, parasitic heat transfer mechanisms, and stack geometry in determining effective thermal performance within layered thermal interfaces. The presented work establishes a foundation for future thermal model correlation efforts and expanded characterization of aerospace thermal interface materials under representative environmental conditions. Future work will focus on the integration of a load cell system to enable controlled pressure-dependent characterization of thermal interface materials under compressive loading. This capability will allow investigation of the influence of contact pressure on effective thermal conductivity, interface resistance, and thermal performance within layered aerospace thermal interfaces under representative operational conditions.

Thermal Development Testing↗

Comparing Growth Rates of Simulated Moist and Dry Convective Thermals

The spreading rates of convective thermals are linked to their net entrainment, and previous literature has suggested differences in spreading rates between moist and dry thermals. Here, growth rates of idealized numerically simulated axisymmetric dry and moist convective thermals are directly compared. In an environment with dry-neutral stratification, the increase of thermal radius with height dR / dz is a larger by a factor of 1.7 for dry thermals relative to moist thermals. The fractional change in thermal volume ε is also greater for dry thermals within a distance of ~4 radii from the initial thermal height. Values of dR / dz are nearly constant with height for both moist and dry thermals consistent with classical theory based on dimensional analysis. The simulations are also consistent with theory relating impulse, circulation, and spreading rate for dry thermals proposed in previous papers and extended here to moist thermals, predicting they will spread less than dry thermals. Tests adding heating to dry thermals, either spread uniformly across the thermal volume or concentrated in the inner core, indicate that dR / dz and ε are smaller for moist thermals because latent heating is confined mostly to their cores. Additional axisymmetric moist simulations using modified lapse rates and large-eddy simulations support this analysis. Overall, these results indicate that slow spreading rates are a fundamental feature of moist thermals caused by latent heating that alters the spatial distribution of buoyancy within them relative to dry thermals.

54 ENVIRONMENTAL SCIENCES↗

Scaling of thermal stratification in outlet plena of SFRs with gallium as a surrogate fluid

Due to its high thermal diffusivity, liquid sodium can develop thermally stratified regions in the hot and cold pools of SFRs under certain off normal operating conditions. The temperature gradients in the fluid give rise to mixed convection flow in which flow velocities result both from pressure gradients and from volume forces induced by density gradients. High thermal diffusivity and low momentum diffusivity leads to reduced thermal mixing and enhanced stratification. Thermal stratification, if not looked carefully in the design, can lead to severe consequences in normal operation with forced coolant circulation and during off-normal natural circulation. The resulting hydraulic and thermal loads can cause the failure modes in structures and components critical for reactor safety. Thermal stratification in the SFR pools can lead to thermal fatigue, which can lead to structural and material failure, or pose serious concerns for the reactor safety. In addition to thermo-structural issues, the reactivity changes are significantly impacted due to density or temperature driven movement of liquid sodium. Temperature changes or gradients in the Upper Instrumentation Structures (UIS) of SFRs can lead to thermal contraction, a case that can lead to positive reactivity insertion after core shut-down. The motivation of this work is to design a scaled down experimental facility which can generate high fidelity data for thermal stratification physics to validate 3-dimensional (3D) Computational Fluid Dynamics (CFD) models. These validated CFD codes can be used to improve the 1-dimensional (1D) system level codes such as SAS4A/SASSYS-1 which are currently not capable of simulating thermal stratification accurately. These improvements in 1D system level SAS4A/SASSYS-1 codes can significantly improve the safety analyses and design of SFRs. The GaTE facility outlet plenum model is designed based on physics based similarities. Thermal stratification physics is governed primarily by the Richardson numbers (Ri). The expected low flow rates during off-normal conditions can lead to a high degree of thermal stratification in the outlet plenum with a corresponding Ri = 530. Therefore, the inlet flow velocities and inlet hydraulic diameter for the gallium coolant entering the test vessel are required to achieve same Ri. The design of test vessel in GaTE facility is finalized to a 1/20. scale outlet plenum height of the ABTR. This design of the test facility will allow the decoupling of the thermal stratification physics at low flow rates with the transient natural circulation. In other words, it will enable effective control to study thermal stratification at very low flow rates. Numerical studies are conducted with a 3D CFD code to examine the thermal behavior of the selected test design. Simulation results show that thermal gradients are present only in the vertical or axial direction which are similar to the behavior reported in previous studies on full scale SFR models. Future work will involve the experimental studies using the GaTE facility with the high fidelity instrumentation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Degradation Characterization of Thermal Interface Greases

Thermal interface materials (TIMs) are used in power electronics packaging to minimize thermal resistance between the heat generating component and the heat sink. Thermal greases are one such class. The conformability and thin bond line thickness (BLT) of these TIMs can potentially provide low thermal resistance throughout the operation lifetime of a component. However, their performance degrades over time due to pump-out and dry-out during thermal and power cycling. The reliability performance of greases through operational cycling needs to be quantified to develop new materials with superior properties. NREL, in collaboration with DuPont, has performed thermal and reliability characterization of several commercially available thermal greases. Initial bulk and contact thermal resistance of grease samples were measured, and then the thermal degradation that occurred due to pump-out and dry-out during temperature cycling was monitored. The thermal resistances of five different grease materials were evaluated using NREL's steady-state thermal resistance tester based on the ASTM test method D5470. Greases were then applied, utilizing a 2.5 cm x 2.5 cm stencil, between invar and aluminum plates to compare the thermomechanical performance of the materials in a representative test fixture. Scanning Acoustic microscopy, thermal, and compositional analyses were performed periodically during thermal cycling from -40 degrees C to 125 degrees C. Completion of this characterization has allowed for a comprehensive evaluation of thermal greases both for their initial bulk and contact thermal performance, as well as their degradation mechanisms under accelerated thermal cycling conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Entropy generation method to quantify thermal comfort

The present paper presents a thermodynamic approach to assess the quality of human-thermal environment interaction and quantify thermal comfort. The approach involves development of entropy generation term by applying second law of thermodynamics to the combined human-environment system. The entropy generation term combines both human thermal physiological responses and thermal environmental variables to provide an objective measure of thermal comfort. The original concepts and definitions form the basis for establishing the mathematical relationship between thermal comfort and entropy generation term. As a result of logic and deterministic approach, an Objective Thermal Comfort Index (OTCI) is defined and established as a function of entropy generation. In order to verify the entropy-based thermal comfort model, human thermal physiological responses due to changes in ambient conditions are simulated using a well established and validated human thermal model developed at the Institute of Environmental Research of Kansas State University (KSU). The finite element based KSU human thermal computer model is being utilized as a "Computational Environmental Chamber" to conduct series of simulations to examine the human thermal responses to different environmental conditions. The output from the simulation, which include human thermal responses and input data consisting of environmental conditions are fed into the thermal comfort model. Continuous monitoring of thermal comfort in comfortable and extreme environmental conditions is demonstrated. The Objective Thermal Comfort values obtained from the entropy-based model are validated against regression based Predicted Mean Vote (PMV) values. Using the corresponding air temperatures and vapor pressures that were used in the computer simulation in the regression equation generates the PMV values. The preliminary results indicate that the OTCI and PMV values correlate well under ideal conditions. However, an experimental study is needed in the future to fully establish the validity of the OTCI formula and the model. One of the practical applications of this index is that could it be integrated in thermal control systems to develop human-centered environmental control systems for potential use in aircraft, mass transit vehicles, intelligent building systems, and space vehicles.

Models, Biological↗

Critical roles of pores and moisture in sustainable nanocellulose-based super-thermal insulators

In a recent report in Matter, Bergström and co-workers describe a novel thermal transport behavior that subverts this assumption of porous materials. In their work, the authors describe a nanocellulose-based foam that features ultrahigh porosity (> 99.6%) and aligned µm-scale pores (10–100 µm) whose radial thermal conductivity (i.e., perpendicular to the pore alignment) is close to that of free air in the dry state. Furthermore, the radial thermal conductivity of the cellulose-based foam can be reduced to ~14 mW/(m·K) when the relative humidity is ~35%. Super-thermal insulators, which demonstrate a thermal conductivity below that of stationary air (~ 25 mW/(m·K), 20 ºC, 1.0 atm), are needed to minimize heat loss in various applications (e.g., buildings, thermal energy storage tanks, cold chain packaging, etc.) to mitigate the energy crisis and reduce carbon emissions. Introducing pores into a material is a facile and effective way to achieve low thermal conductivity as pores can suppress thermal transport through solids by reducing the cross-sectional area and increasing the tortuosity of the heat transfer pathway. In porous structures there are two kinds of pores: open and closed. While increased porosity can reduce heat conduction through solids with an open porous structure, the improved gas conduction creates a competing effect that simultaneously elevates the heat transfer. Therefore, the thermal conductivity of a material with µm-scale open pores is usually larger than that of stationary air. Reducing the pore size to less than the mean free path of air (~ 70 nm, 20 ºC, 1.0 atm) can effectively reduce gas conduction, enabling the material to achieve a thermal conductivity below that of stationary air. However, high cost of the nanosized raw materials and time-consuming fabrication processes limit the large-scale applications of nanoporous thermal insulators. Meanwhile, closed pores can block heat transport only through the continuous gas phase. As a result, the thermal conductivity of a closed porous structure can theoretically be much smaller than that of stationary air if the solid conduction can also be suppressed by (1) lowering the solid content of the material, (2) reducing the thermal conductivity of the building blocks of the material, and/or (3) increasing interfacial thermal resistance between neighboring building blocks. Most processes used to generate porous structures (e.g., supercritical drying, freeze drying) involve a solvent that escapes the material. Therefore, it is difficult to create pores and isolate them simultaneously, preventing the fabrication of super-thermal insulators with closed pores.

36 MATERIALS SCIENCE↗

NASA Passive Thermal Control Engineering Guidebook

The NASA Passive Thermal Control Engineering Guidebook provides recommendations, including best practices and lessons learned, related to the passive thermal control engineering discipline. Topics include analysis (including documentation and review), thermal hardware (design/selection, vendors, and integration), testing, and flight operations. The passive thermal discipline includes thermal control and thermal protection systems. The passive thermal control discipline, which is addressed in this Guidebook, is broad and covers internal and external systems, component passive thermal analysis, vehicle on-orbit attitude timeline analysis, integrated thermal analysis, various thermal control apparatus (heaters and controls, coatings, blankets and insulations, isolators, geometric design for view factors, materials emissivity/absorptivity properties), passive cooling of avionics, purge, vent, and drain for vehicle cavities and compartments, thermal model development and correlation, thermal cycle and thermal-vacuum testing. Topics related to thermal protection systems (TPS) are not within the scope of this document. The Guidebook provides a consolidated reference for early career as well as experienced engineers embarking on a new task. Leveraging the experience of the group minimizes the learning curve that exists at the start of new projects, reduces the risk of repeating mistakes, and improves the organization’s ability to deliver high-quality products efficiently. The intent of this document is to provide guidance based on collective experience, and is not intended impose constraints on project work. Best practices can vary substantially and it is important to apply judgment wisely based on careful consideration of the specific design and requirements. Implementation of the methods described will vary from project to project and should be applied in conjunction with the judgment of the thermal engineers performing and reviewing the work. The recommendations in this document are not intended to replace program, project, branch, Center, or NASA requirements and/or policies.

thermal↗

NASA Passive Thermal Control Engineering Guidebook

The NASA Passive Thermal Control Engineering Guidebook provides recommendations, including best practices and lessons learned, related to the passive thermal control engineering discipline. Topics include analysis (including documentation and review), thermal hardware (design/selection, vendors, and integration), testing, and flight operations. The passive thermal discipline includes thermal control and thermal protection systems. The passive thermal control discipline, which is addressed in this Guidebook, is broad and covers internal and external systems, component passive thermal analysis, vehicle on-orbit attitude timeline analysis, integrated thermal analysis, various thermal control apparatus (heaters and controls, coatings, blankets and insulations, isolators, geometric design for view factors, materials emissivity/absorptivity properties), passive cooling of avionics, purge, vent, and drain for vehicle cavities and compartments, thermal model development and correlation, thermal cycle and thermal-vacuum testing. Topics related to thermal protection systems (TPS) are not within the scope of this document. The Guidebook provides a consolidated reference for early career as well as experienced engineers embarking on a new task. Leveraging the experience of the group minimizes the learning curve that exists at the start of new projects, reduces the risk of repeating mistakes, and improves the organization’s ability to deliver high-quality products efficiently. The intent of this document is to provide guidance based on collective experience, and is not intended impose constraints on project work. Best practices can vary substantially and it is important to apply judgment wisely based on careful consideration of the specific design and requirements. Implementation of the methods described will vary from project to project and should be applied in conjunction with the judgment of the thermal engineers performing and reviewing the work. The recommendations in this document are not intended to replace program, project, branch, Center, or NASA requirements and/or policies.

thermal↗

Enhanced Thermal Conductivity UO{sub 2}-BeO and UO{sub 2}-SiC Fuels Behavior

Commercial light-water reactors currently use UO{sub 2} as a nuclear fuel, which has demonstrated several desirable characteristics. However, UO{sub 2} has a low thermal conductivity that leads to the development of a large temperature gradient across the fuel pellet. This temperature gradient contributes to limits in the operational performance of the reactor due to effects that include thermal stresses causing pellet cladding interaction and the release of fission product gases as demonstrated. These high fuel temperatures can be decreased and reactor performance improved by developing an enhanced thermal conductivity nuclear fuel. A high thermal conductivity nuclear fuel would decrease fuel temperatures and facilitate a reduction in pellet cladding interaction through lessening thermal stresses that result in fuel cracking, relocation, and swelling as described. Additionally, fission gas release would be decreased allowing for higher fuel burn-up, and the safety of the reactor would be improved with a faster thermal response and less stored energy in the fuel pins. A ceramic-ceramic composite nuclear fuel has an increased effective thermal conductivity due to adding a second compatible and high thermal conductivity ceramic to UO{sub 2}. SiC and BeO are two materials that demonstrate compatibility with UO{sub 2} and have a high thermal conductivity. In summary, the enhanced thermal conductivity UO{sub 2}-BeO and UO{sub 2}-SiC fuel performance has been modelled in a light water reactor, and a more complete and detailed understanding was achieved for enhanced thermal conductivity UO{sub 2}-BeO and UO{sub 2}-SiC fuels. BeO and SiC have high melting point, low neutron absorption, low thermal expansion coefficient and chemical compatibility with current UO{sub 2} fuels which makes them a suitable material for thermal conductivity enhancement. In our modeling and simulation work, the enhanced thermal conductivity nuclear fuel showed the capability of decreasing the fuel temperatures, increasing the gap total conductance, reducing the fission gas release, decreasing the gap/plenum pressure, lessening oxygen redistribution, and facilitating a reduction in pellet cladding interaction through lessening thermal stresses that result in fuel cracking, relocation, and swelling. The safety of the reactor operation would be then improved. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermal Conductivity and Diffusivity for SiC Fibers for Use in ATF Cladding Composites

As part of the accident tolerant fuels (ATF) initiative, there is a need to understand the thermophysical properties of cladding for these fuels. One potential cladding material is silicon carbide (SiC) ceramic matrix composite reinforced with SiC fibers because of the corrosion resistance, resistance to hydrogen formation, high bulk thermal conductivity, and favorable mechanical properties of SiC. However, data about the thermal properties of individual SiC fibers in these composites is absent in the literature. This paper presents the measured axial thermal conductivity and thermal diffusivity of a leading SiC fiber (HiNicalon Type S) via a thermal measurement technique (transient electrothermal technique, TET) optimized for thin fibers. The results show that the measured properties are significantly lower than bulk values for SiC. Because of the low neutron absorption, as well as excellent thermal and mechanical properties, zircaloy has primarily been used for the fuel cladding in many nuclear reactors. A major drawback of the zircaloy is its hydrogen generation vulnerability. This issue has been known for some time, but the explosion of hydrogen accident in the Fukushima Daiichi nuclear disaster has motivated efforts for accident tolerant fuels (ATF) and their cladding as suitable substitutes for zircaloy. Fuel cladding made of silicon carbide (SiC) ceramic matrix composite (CMC) is an attractive alternative to the zircaloy. Investigation on the tubular monolithic a-SiC polytropes indicates that it has superior oxidation (hydrogen production) resistance (three orders of magnitude slower) than zircaloy. Additionally, it has well-documented, favorable mechanical properties, along with high temperature corrosion resistance. However, its bulk thermal properties can vary significantly depending on polytrope, the grain size, grain boundary, or impurities. At room temperature, SiC has a thermal conductivity as high as 490 Wm{sup -1}K{sup -1}, where the {sup 6}H polytrope has the highest conductivity. Thermal measurements of the SiC CMC are usually accomplished by laser flash method for thermal diffusivity (a) and thermal conductivity is indirectly calculated through the relationship k=aρcp. Depending on the manufacturing method and the reinforced fiber, the composite thermal conductivity varies from <10 Wm{sup -1}K{sup -1} to ∼70 Wm{sup -1}K{sup -1}. While the flash method is convenient for the measurement of the composite, it is difficult to apply to the measurement of individual fibers. Because of this, the thermal properties of individual SiC fibers is not present in the literature. Because the SiC fiber manufacturing process is different than that of the SiC matrix in the CMC, the properties of the bulk material might be erroneous when applied to the fiber. Being able to measure the fiber properties independently and directly allows for an understanding of the effect of the manufacturing process on the fiber and the opportunity to potentially improve or control the thermal properties of the composite. This improved accuracy can be achieved by measuring the fiber with a technique optimized for individual fiber measurement, known as the Transient Electrothermal Technique or TET. This paper presents the thermal conductivity and diffusivity of a leading SiC fiber (HiNicalon Type S). Measurements are performed with the TET, with the resulting properties being significantly lower than the bulk values of SiC, which is one possible explanation for relatively low CMC values. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Understanding Thermal Transport in Polymer –Silver Nanowire Composites

Understanding thermal transport across filler-polymer interfaces and filler-filler contacts within polymer composites is of great importance for better thermal design of the composites that are widely used in high-performance heat exchangers, energy storage devices, and flexible electronics. Over the past several decades, considerable progress has been made in improving the thermal conductivity of polymer composites, but several key questions concerning the influence of interfacial thermal resistance, or Kapitza resistance, still remain. Firstly, the thermal properties of these composites are highly dependent on thermal transport through the filler network and its contacts. For metallic nanofillers, the thermal conductivity is often estimated using the Wiedemann-Franz law based on electrical conductivity; however, it remains a question whether the Wiedemann-Franz law still holds at nanoscale contacts. Through investigation of silver nanowires of varying sizes, we were able to demonstrate that the Lorenz number for silver nanowire increases with decreasing nanowire diameter. Examination of the corresponding electrical and thermal conductivities indicate that these changes are due to that the relative contribution of phonons becomes more significant as a result of elastic stiffening. Furthermore, we show that for silver nanowires, the contact thermal resistance is ~8 times lower than that of multi-walled carbon nanotube (MWCNT) of similar diameters. Additionally, through systematic studies of electrospun polymer-silver nanowire composite nanofibers, we investigated the impact of interface morphology on the thermal conductivity enhancement of the composite system and probed the value of the Kapitza resistance for individual polymer-filler interfaces. For polymer nanofibers containing continuous, single silver nanowires, the thermal conductivity increases linearly with increasing volume fraction of silver, which is consistent with the prediction of percolation theory for samples above the percolation limit. By comparing this linear trend to the measured thermal conductivities of composite nanofibers with more complex structures, we were able to determine the resistance associated with any additional polymer-filler boundaries. In doing so we find that the thermal boundary resistance for polyvinylpyrrolidone (PVP)–silver interfaces is significantly lower than that of comparable polymer-MWCNT composite systems.Together our studies provide new insights into thermal transport in polymer nanocomposites and should help facilitate the design of high performance polymeric thermal interface material.

Thermal transport↗

Entrainment, Detrainment, and Dilution of Dry and Moist Atmospheric Thermals

Here this study examines the entrainment, detrainment, and dilution of dry and moist (cloud) atmospheric thermals in large-eddy simulations. In a neutrally stable environment (with respect to dry dynamics), moist thermals have an increase in radius R with thermal height z t (α ≡ dR/dz t ) about 4 times smaller compared to dry thermals when density stratification is considered and ~2.4 times smaller without density stratification (i.e., applying the Boussinesq approximation). An analytic expression relating α to several dimensionless parameters is derived from the thermal impulse–circulation relation to clarify the factors impacting α. This expression shows that the difference in buoyancy structure between moist and dry thermals, with buoyancy concentrated in the central cores of moist thermals owing to latent heating, explains their smaller spreading rates. Individual contributions of entrainment and detrainment are analyzed using a direct parcel-based approach in the simulations. Moist thermals have similar fractional detrainment but much smaller fractional entrainment rates compared to dry thermals, consistent with the differences in α. Despite having smaller α, moist thermals are similarly dilute (quantified by a passive tracer) as dry thermals because of their greater mixing efficiency with the environment. Thus, moist thermals are substantially dilute but expand much less in size/volume as they rise compared to dry thermals. The α values for moist thermals in (dry) neutral and statically stable environments are similar, but fractional entrainment and especially detrainment rates are greater in the stable environment. Large detrainment rates are associated with a breakdown of the broader thermal vortex ring structure, especially with low environmental relative humidity, attributed in part to evaporation and buoyancy reversal.

54 ENVIRONMENTAL SCIENCES↗

Understanding Thermal Transport in Polymer - Silver Nanowire Composites

Understanding thermal transport across filler-polymer interfaces and filler-filler contacts within polymer composites is of great importance for better thermal design of the composites that are widely used in high-performance heat exchangers, energy storage devices, and flexible electronics. Over the past several decades, considerable progress has been made in improving the thermal conductivity of polymer composites, but several key questions concerning the influence of interfacial thermal resistance, or Kapitza resistance, still remain. Firstly, the thermal properties of these composites are highly dependent on thermal transport through the filler network and its contacts. For metallic nanofillers, the thermal conductivity is often estimated using the Wiedemann-Franz law based on electrical conductivity; however, it remains a question whether the Wiedemann-Franz law still holds at nanoscale contacts. Through investigation of silver nanowires of varying sizes, we were able to demonstrate that the Lorenz number for silver nanowire increases with decreasing nanowire diameter. Examination of the corresponding electrical and thermal conductivities indicate that these changes are due to that the relative contribution of phonons becomes more significant as a result of elastic stiffening. Furthermore, we show that for silver nanowires, the contact thermal resistance is ~8 times lower than that of multi-walled carbon nanotube (MWCNT) of similar diameters. Additionally, through systematic studies of electrospun polymer-silver nanowire composite nanofibers, we investigated the impact of interface morphology on the thermal conductivity enhancement of the composite system and probed the value of the Kapitza resistance for individual polymer-filler interfaces. For polymer nanofibers containing continuous, single silver nanowires, the thermal conductivity increases linearly with increasing volume fraction of silver, which is consistent with the prediction of percolation theory for samples above the percolation limit. By comparing this linear trend to the measured thermal conductivities of composite nanofibers with more complex structures, we were able to determine the resistance associated with any additional polymer-filler boundaries. In doing so we find that the thermal boundary resistance for polyvinylpyrrolidone (PVP)–silver interfaces is significantly lower than that of comparable polymer-MWCNT composite systems. Together our studies provide new insights into thermal transport in polymer nanocomposites and should help facilitate the design of high performance polymeric thermal interface material.

Matthew L. Fitzgerald↗

Thermal Performance Benchmarking: Annual Report

In FY16, the thermal performance of the 2014 Honda Accord Hybrid power electronics thermal management systems were benchmarked. Both experiments and numerical simulation were utilized to thoroughly study the thermal resistances and temperature distribution in the power module. Experimental results obtained from the water-ethylene glycol tests provided the junction-to-liquid thermal resistance. The finite element analysis (FEA) and computational fluid dynamics (CFD) models were found to yield a good match with experimental results. Both experimental and modeling results demonstrate that the passive stack is the dominant thermal resistance for both the motor and power electronics systems. The 2014 Accord power electronics systems yield steady-state thermal resistance values around 42- 50 mm to the 2nd power K/W, depending on the flow rates. At a typical flow rate of 10 liters per minute, the thermal resistance of the Accord system was found to be about 44 percent lower than that of the 2012 Nissan LEAF system that was benchmarked in FY15. The main reason for the difference is that the Accord power module used a metalized-ceramic substrate and eliminated the thermal interface material layers. FEA models were developed to study the transient performance of 2012 Nissan LEAF, 2014 Accord, and two other systems that feature conventional power module designs. The simulation results indicate that the 2012 LEAF power module has lowest thermal impedance at a time scale less than one second. This is probably due to moving low thermally conductive materials further away from the heat source and enhancing the heat spreading effect from the copper-molybdenum plate close to the insulated gate bipolar transistors. When approaching steady state, the Honda system shows lower thermal impedance. Measurement results of the thermal resistance of the 2015 BMW i3 power electronic system indicate that the i3 insulated gate bipolar transistor module has significantly lower junction-to-liquid thermal resistance as compared to the other systems. At a flow rate of 12 liters per minute, the thermal resistance of the i3 systems is only 30 percent of the Accord system and 15 percent of the LEAF system.

30 DIRECT ENERGY CONVERSION↗

Battery Thermal Characterization

A well-designed thermal management system is critical to the life and performance of electric-drive vehicles (EDVs) hybrids (HEVs), plug-in hybrids (PHEVs), and all-electric vehicles (EVs). Temperature and temperature uniformity both significantly affect the performance, lifespan, and safety of vehicle energy storage devices. NREL conducts thermal management research and development (R&D) to optimize battery performance and extend useful life. A recognized leader in battery thermal analysis and characterization, NREL evaluates electrical and thermal performance of battery cells, modules, and packs, full energy storage systems, and the interaction of these systems with other vehicle components. The lab's performance assessments factor in the design of the thermal management system, the thermal behavior of the cell, battery lifespan, and safety of the energy storage system, as well as full integration into a vehicle. The lithium-ion (Li-ion) batteries found in most of today's electric-drive vehicles are smaller and more lightweight than previous nickel-metal hydride (NiMH) technology, but they are also more sensitive to overheating, overcharging, and extreme spikes in temperature known as thermal runaway. High temperatures diminish battery life and increase battery replacement costs, while low temperatures decrease battery power and capacity, all of which impact vehicle range, performance, and affordability. NREL's breakthrough research is focused on reducing thermal barriers to achieve more uniform temperatures. NREL uses its R&D 100 Award-winning Isothermal Battery Calorimeters, the only instruments in the world capable of such precise thermal measurements, for much of this research. Calorimeter readings are paired with thermal imaging of batteries using infrared cameras to evaluate battery temperature distribution. In addition, NREL is working with industry to develop computer-aided engineering software tools to optimize thermal management of batteries. NREL's analysis for the U.S. Advanced Battery Consortium (USABC) show that optimized thermal management can increase battery power by more than 10%. Without proper thermal management, an EDV battery can last more than 10 years in a temperate climate, like in Minnesota, but only 7 years in a hot climate, such as in Arizona. In extreme instances, battery overheating can pose safety hazards, including fires. Performance: Maintaining desired temperature ranges is critical in optimizing EDV battery storage capacity, lifespan, and performance, and eventually impacts cost and consumer acceptance. NREL's breakthrough research focuses on achieving more uniform temperatures while a vehicle is in motion and actively generating heat, as well as when it is parked and exposed to ambient temperatures over prolonged periods of time. Safety: Most energy storage systems deliver maximum performance at higher temperatures. However, this extreme heat can overload systems and create dangerous conditions. NREL evaluation helps to more effectively regulate thermal characteristics, providing greater safeguards and stronger performance. NREL has invented a device that emulates internal short circuits in batteries to better understand how to prevent future failures and related hazards.

25 ENERGY STORAGE↗