Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Systematic Error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Phantom and Clinical Study of Differences in Cone Beam Computed Tomographic Registration When Aligned to Maximum and Average Intensity Projection

Purpose: To determine whether maximum or average intensity projection (MIP or AIP, respectively) reconstructed from 4-dimensional computed tomography (4DCT) is preferred for alignment to cone beam CT (CBCT) images in lung stereotactic body radiation therapy. Methods and Materials: Stationary CT and 4DCT images were acquired with a target phantom at the center of motion and moving along the superior–inferior (SI) direction, respectively. Motion profiles were asymmetrical waveforms with amplitudes of 10, 15, and 20 mm and a 4-second cycle. Stationary CBCT and dynamic CBCT images were acquired in the same manner as stationary CT and 4DCT images. Stationary CBCT was aligned to stationary CT, and the couch position was used as the baseline. Dynamic CBCT was aligned to the MIP and AIP of corresponding amplitudes. Registration error was defined as the SI deviation of the couch position from the baseline. In 16 patients with isolated lung lesions, free-breathing CBCT (FBCBCT) was registered to AIP and MIP (64 sessions in total), and the difference in couch shifts was calculated. Results: In the phantom study, registration errors were within 0.1 mm for AIP and 1.5 to 1.8 mm toward the inferior direction for MIP. In the patient study, the difference in the couch shifts (mean, range) was insignificant in the right-left (0.0 mm, ≤1.0 mm) and anterior–posterior (0.0 mm, ≤2.1 mm) directions. In the SI direction, however, the couch position significantly shifted in the inferior direction after MIP registration compared with after AIP registration (mean, −0.6 mm; ranging 1.7 mm to the superior side and 3.5 mm to the inferior side, P=.02). Conclusions: AIP is recommended as the reference image for registration to FBCBCT when target alignment is performed in the presence of asymmetrical respiratory motion, whereas MIP causes systematic target positioning error.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On the potentially transformative role of auxiliary-field quantum Monte Carlo in quantum chemistry: A highly accurate method for transition metals and beyond

Approximate solutions to the ab initio electronic structure problem have been a focus of theoretical and computational chemistry research for much of the past century, with the goal of predicting relevant energy differences to within “chemical accuracy” (1 kcal/mol). For small organic molecules, or in general, for weakly correlated main group chemistry, a hierarchy of single-reference wave function methods has been rigorously established, spanning perturbation theory and the coupled cluster (CC) formalism. For these systems, CC with singles, doubles, and perturbative triples is known to achieve chemical accuracy, albeit at O(N7) computational cost. In addition, a hierarchy of density functional approximations of increasing formal sophistication, known as Jacob’s ladder, has been shown to systematically reduce average errors over large datasets representing weakly correlated chemistry. However, the accuracy of such computational models is less clear in the increasingly important frontiers of chemical space including transition metals and f-block compounds, in which strong correlation can play an important role in reactivity. A stochastic method, phaseless auxiliary-field quantum Monte Carlo (ph-AFQMC), has been shown to be capable of producing chemically accurate predictions even for challenging molecular systems beyond the main group, with relatively low O(N3 − N4) cost and near-perfect parallel efficiency. Herein, we present our perspectives on the past, present, and future of the ph-AFQMC method. We focus on its potential in transition metal quantum chemistry to be a highly accurate, systematically improvable method that can reliably probe strongly correlated systems in biology and chemical catalysis and provide reference thermochemical values (for future development of density functionals or interatomic potentials) when experiments are either noisy or absent. Finally, we discuss the present limitations of the method and where we expect near-term development to be most fruitful.

Chemistry↗

QUANTIFYING PHOTOMETRIC REDSHIFT ERRORS IN THE ABSENCE OF SPECTROSCOPIC REDSHIFTS

Much of the science that is made possible by multiwavelength redshift surveys requires the use of photometric redshifts. But as these surveys become more ambitious, and as we seek to perform increasingly accurate measurements, it becomes crucial to take proper account of the photometric redshift uncertainties. Ideally the uncertainties can be directly measured using a comparison with spectroscopic redshifts, but this may yield misleading results since spectroscopic samples are frequently small and not representative of the parent photometric samples. We present a simple and powerful empirical method to constrain photometric redshift uncertainties in the absence of spectroscopic redshifts. Close pairs of galaxies on the sky have a significant probability of being physically associated and therefore of lying at nearly the same redshift. The difference in photometric redshifts in close pairs is therefore a measure of the redshift uncertainty. Some observed close pairs will arise from chance projections along the line of sight, but it is straightforward to perform a statistical correction for this effect. We demonstrate the technique using both simulated data and actual observations, and discuss how its usefulness can be limited by the presence of systematic photometric redshift errors. Finally, we use this technique to show how photometric redshift accuracy can depend on galaxy type.

79 ASTRONOMY AND ASTROPHYSICS↗

Interfraction and Intrafraction Setup Variability for Prone Breast Radiation Therapy

Purpose: To report the interfraction and intrafraction setup variation for prone breast radiotherapy and to determine an appropriate clinical tumor volume (CTV) to planning target volume (PTV) margin to account for motion and positional uncertainties. Methods and Materials: Ten consecutive patients were prospectively enrolled in a protocol of accelerated, hypofractionated prone breast irradiation. Portal images were acquired using an electronic portal imaging device in cine mode. Interfraction setup error was determined by comparing the first image from each fraction with the digitally reconstructed radiograph. The intrafraction motion was determined by evaluating every image acquired during each fraction and measuring the maximum displacement of an external fiducial and the breast surface. Mean values and 95% confidence intervals (CI) were calculated. Based on these results, a CTV to PTV expansion was derived using the equation M = 2.5SIGMA{sub tot} + 0.7sigma{sub tot.} Results: The mean interfraction setup variability for the fiducial was 0.08 cm (CI: 0.02-0.14) in the anterior to posterior (AP) direction and -0.04 cm (CI: -0.07-0.00) in the superior to inferior (SI) direction. The mean interfraction variability of the breast surface was -0.14 cm (CI: -0.24 to -0.04) in the AP direction. The mean intrafraction displacements of the fiducial and the breast surface were 0.13 cm (CI: 0.12-0.15) and 0.15 cm (CI: 0.14-0.17), respectively. Using the systematic and random errors for the external fiducial, the calculated CTV to PTV expansion was 1.4 cm. Conclusions: Acceptable interfraction and intrafraction variability were demonstrated. The findings resulted in a CTV to PTV expansion of 1.4 cm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Extended Forward Sensitivity Analysis for Uncertainty Quantification

Verification and validation (V&V) are playing more important roles to quantify uncertainties and realize high fidelity simulations in engineering system analyses, such as transients happened in a complex nuclear reactor system. Traditional V&V in the reactor system analysis focused more on the validation part or did not differentiate verification and validation. The traditional approach to uncertainty quantification is based on a 'black box' approach. The simulation tool is treated as an unknown signal generator, a distribution of inputs according to assumed probability density functions is sent in and the distribution of the outputs is measured and correlated back to the original input distribution. The 'black box' method mixes numerical errors with all other uncertainties. It is also not efficient to perform sensitivity analysis. Contrary to the 'black box' method, a more efficient sensitivity approach can take advantage of intimate knowledge of the simulation code. In these types of approaches equations for the propagation of uncertainty are constructed and the sensitivities are directly solved for as variables in the simulation. This paper presents the forward sensitivity analysis as a method to help uncertainty qualification. By including time step and potentially spatial step as special sensitivity parameters, the forward sensitivity method is extended as one method to quantify numerical errors. Note that by integrating local truncation errors over the whole system through the forward sensitivity analysis process, the generated time step and spatial step sensitivity information reflect global numerical errors. The discretization errors can be systematically compared against uncertainties due to other physical parameters. This extension makes the forward sensitivity method a much more powerful tool to help uncertainty qualification. By knowing the relative sensitivity of time and space steps with other interested physical parameters, the simulation is allowed to run at optimized time and space steps without affecting the confidence of the physical parameter sensitivity results. The time and space steps forward sensitivity analysis method can also replace the traditional time step and grid convergence study with much less computational cost. Several well defined benchmark problems with manufactured solutions are utilized to demonstrate the extended forward sensitivity analysis method. All the physical solutions, parameter sensitivity solutions, even the time step sensitivity in one case, have analytical forms, which allows the verification to be performed in the strictest sense.

97 MATHEMATICS AND COMPUTING↗

RESIDUAL HUBBLE-BUBBLE EFFECTS ON SUPERNOVA COSMOLOGY

Even in a universe that is homogeneous on large scales, local density fluctuations can imprint a systematic signature on the cosmological inferences we make from distant sources. One example is the effect of a local underdensity on supernova cosmology. Also known as a Hubble-bubble, it has been suggested that a large enough underdensity could account for the supernova magnitude-redshift relation without the need for dark energy or acceleration. Although the size and depth of the underdensity required for such an extreme result is extremely unlikely to be a random fluctuation in an on-average homogeneous universe, even a small underdensity can leave residual effects on our cosmological inferences. It is these small underdensities that we consider here. In this paper, we show that there remain systematic shifts in our cosmological parameter measurements, even after excluding local supernovae that are likely to be within any small Hubble-bubble. We study theoretically the low-redshift cutoff typically imposed by supernova cosmology analyses and show that a low-redshift cut of z {sub 0} {approx} 0.02 may be too low based on the observed inhomogeneity in our local universe. Neglecting to impose any low-redshift cutoff can have a significant effect on the cosmological parameters derived from supernova data. A slight local underdensity, just 30% underdense with scale 70 h {sup -1} Mpc, causes an error in the inferred cosmological constant density {Omega}{sub {Lambda}} of {approx}4%. Imposing a low-redshift cutoff reduces this systematic error but does not remove it entirely. A residual systematic shift of 0.99% remains in the inferred value {Omega}{sub {Lambda}} even when neglecting all data within the currently preferred low-redshift cutoff of 0.02. Given current measurement uncertainties, this shift is not negligible and will need to be accounted for when future measurements yield higher precision.

79 ASTRONOMY AND ASTROPHYSICS↗

ESTIMATING THE PROPERTIES OF HARD X-RAY SOLAR FLARES BY CONSTRAINING MODEL PARAMETERS

We wish to better constrain the properties of solar flares by exploring how parameterized models of solar flares interact with uncertainty estimation methods. We compare four different methods of calculating uncertainty estimates in fitting parameterized models to Ramaty High Energy Solar Spectroscopic Imager X-ray spectra, considering only statistical sources of error. Three of the four methods are based on estimating the scale-size of the minimum in a hypersurface formed by the weighted sum of the squares of the differences between the model fit and the data as a function of the fit parameters, and are implemented as commonly practiced. The fourth method is also based on the difference between the data and the model, but instead uses Bayesian data analysis and Markov chain Monte Carlo (MCMC) techniques to calculate an uncertainty estimate. Two flare spectra are modeled: one from the Geostationary Operational Environmental Satellite X1.3 class flare of 2005 January 19, and the other from the X4.8 flare of 2002 July 23. We find that the four methods give approximately the same uncertainty estimates for the 2005 January 19 spectral fit parameters, but lead to very different uncertainty estimates for the 2002 July 23 spectral fit. This is because each method implements different analyses of the hypersurface, yielding method-dependent results that can differ greatly depending on the shape of the hypersurface. The hypersurface arising from the 2005 January 19 analysis is consistent with a normal distribution; therefore, the assumptions behind the three non-Bayesian uncertainty estimation methods are satisfied and similar estimates are found. The 2002 July 23 analysis shows that the hypersurface is not consistent with a normal distribution, indicating that the assumptions behind the three non-Bayesian uncertainty estimation methods are not satisfied, leading to differing estimates of the uncertainty. We find that the shape of the hypersurface is crucial in understanding the output from each uncertainty estimation technique, and that a crucial factor determining the shape of hypersurface is the location of the low-energy cutoff relative to energies where the thermal emission dominates. The Bayesian/MCMC approach also allows us to provide detailed information on probable values of the low-energy cutoff, E{sub c} , a crucial parameter in defining the energy content of the flare-accelerated electrons. We show that for the 2002 July 23 flare data, there is a 95% probability that E{sub c} lies below approximately 40 keV, and a 68% probability that it lies in the range 7-36 keV. Further, the low-energy cutoff is more likely to be in the range 25-35 keV than in any other 10 keV wide energy range. The low-energy cutoff for the 2005 January 19 flare is more tightly constrained to 107 {+-} 4 keV with 68% probability. Using the Bayesian/MCMC approach, we also estimate for the first time probability density functions for the total number of flare-accelerated electrons and the energy they carry for each flare studied. For the 2002 July 23 event, these probability density functions are asymmetric with long tails orders of magnitude higher than the most probable value, caused by the poorly constrained value of the low-energy cutoff. The most probable electron power is estimated at 10{sup 28.1} erg s{sup -1}, with a 68% credible interval estimated at 10{sup 28.1}-10{sup 29.0} erg s{sup -1}, and a 95% credible interval estimated at 10{sup 28.0}-10{sup 30.2} erg s{sup -1}. For the 2005 January 19 flare spectrum, the probability density functions for the total number of flare-accelerated electrons and their energy are much more symmetric and narrow: the most probable electron power is estimated at 10{sup 27.66{+-}0.01} erg s{sup -1} (68% credible intervals). However, in this case the uncertainty due to systematic sources of error is estimated to dominate the uncertainty due to statistical sources of error.

79 ASTRONOMY AND ASTROPHYSICS↗

STEPS: A Grid Search Methodology for Optimized Peptide Identification Filtering of MS/MS Database Search Results

For bottom-up proteomics there are a wide variety of database searching algorithms in use for matching peptide sequences to tandem MS spectra. Likewise, there are numerous strategies being employed to produce a confident list of peptide identifications from the different search algorithm outputs. Here we introduce a grid search approach for determining optimal database filtering criteria in shotgun proteomics data analyses that is easily adaptable to any search. Systematic Trial and Error Parameter Selection - referred to as STEPS - utilizes user-defined parameter ranges to test a wide array of parameter combinations to arrive at an optimal "parameter set" for data filtering, thus maximizing confident identifications. The benefits of this approach in terms of numbers of true positive identifications are demonstrated using datasets derived from immunoaffinity-depleted blood serum and a bacterial cell lysate, two common proteomics sample types.

Environmental Molecular Sciences Laboratory↗

Teleconnections of the Quasi–Biennial Oscillation in a multi–model ensemble of QBO–resolving models

The quasi-biennial oscillation (QBO) dominates the interannual variability of the tropical stratosphere and influences other regions of the atmosphere. The high predictability of the QBO implies that its teleconnections could lead to in-creased skill of seasonal and decadal forecasts provided the relevant mechanisms are accurately represented in models. Here modelling and sampling uncertainties of QBO teleconnections are examined using a multi-model ensemble of QBO-resolving atmospheric general circulation models that have carried out a set of coordinated experiments as part of the Stratosphere-troposphere Processes And their Role in Climate (SPARC) QBO initiative (QBOi). During Northern Hemisphere winter the stratospheric polar vortex in most of these models strengthens when the QBO near 50 hPa is westerly and weakens when it is easterly, consistent with, but weaker than, the observed response. These weak responses are likely due to model errors, such as systematically weak QBO amplitudes near 50 hPa, affecting the teleconnection. The teleconnection to the North Atlantic Oscillation is less well captured overall, but of similar strength to the observed signal in the few models that do show it. Furthermore, the models do not show clear evidence of a QBO teleconnection to the Northern Hemisphere Pacific sector subtropical jet.

54 ENVIRONMENTAL SCIENCES↗

Adaptive Radiotherapy for Prostate Cancer Using Kilovoltage Cone-Beam Computed Tomography: First Clinical Results

Purpose: To evaluate the first clinical results of an off-line adaptive radiotherapy (ART) protocol for prostate cancer using kilovoltage cone-beam computed tomography (CBCT) in combination with a diet and mild laxatives. Methods and Materials: Twenty-three patients began treatment with a planning target volume (PTV) margin of 10 mm. The CBCT scans acquired during the first six fractions were used to generate an average prostate clinical target volume (AV-CTV), and average rectum (AV-Rect). Using these structures, a new treatment plan was generated with a 7-mm PTV margin. Weekly CBCT scans were used to monitor the CTV coverage. A diet and mild laxatives were introduced to improve image quality and reduce prostate motion. Results: Twenty patients were treated with conform ART protocol. For these patients, 91% of the CBCT scans could be used to calculate the AV-CTV and AV-Rect. In 96% of the follow-up CBCT scans, the CTV was located within the average PTV. In the remaining 4%, the prostate extended the PTV by a maximum of 1 mm. Systematic and random errors for organ motion were reduced by a factor of two compared with historical data without diet and laxatives. An average PTV reduction of 29% was achieved. The volume of the AV-Rect that received >65 Gy was reduced by 19%. The mean dose to the anal wall was reduced on average by 4.8 Gy. Conclusions: We safely reduced the high-dose region by 29%. The reduction in irradiated volume led to a significant reduction in the dose to the rectum. The diet and laxatives improved the image quality and tended to reduce prostate motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Cone Beam CT-Based Study for Clinical Target Definition Using Pelvic Anatomy During Postprostatectomy Radiotherapy

Purpose: There are no accepted guidelines for target volume definition for online image-guided radiation therapy (IGRT) after radical prostatectomy (RP). This study used cone beam CT (CBCT) imaging to generate information for use in post-RP IGRT. Methods and Materials: The pelvic anatomy of 10 prostate cancer patients undergoing post-RP radiation therapy (RT) to 68.4 Gy was studied using CBCT images obtained immediately before treatment. Contoured bladder and rectal volumes on CBCT images were compared with planning CT (CT{sub ref}) volumes from seminal vesicle stump (SVS) to bladder-urethral junction. This region was chosen to approximate the prostatic fossa (PF) during a course of post-RP RT. Anterior and posterior planning target volume margins were calculated using ICRU report 71 guidelines, accounting for systematic and random error based on bladder and rectal motion, respectively. Results: A total of 176 CBCT study sets obtained 2 to 5 times weekly were analyzed. The rectal and bladder borders were reliably identified in 166 of 176 (94%) of CBCT images. Relative to CT{sub ref}, mean posterior bladder wall position was anterior by 0.1 to 1.5 mm, and mean anterior rectum wall position was posterior by 1.6 to 2.7 mm. Calculated anterior margin as derived from bladder motion ranged from 5.9 to 7.1 mm. Calculated posterior margin as derived from rectal motion ranged from 8.6 to 10.2 mm. Conclusions: Normal tissue anatomy was definable by CBCT imaging throughout the course of post-RP RT, and the interfraction anteroposterior motion of the bladder and rectum was studied. This information should be considered in devising post-RP RT techniques using image guidance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Differential Motion Between Mediastinal Lymph Nodes and Primary Tumor in Radically Irradiated Lung Cancer Patients

Purpose/Objective: In patients with locally advanced lung cancer, planning target volume margins for mediastinal lymph nodes and tumor after a correction protocol based on bony anatomy registration typically range from 1 to 1.5 cm. Detailed information about lymph node motion variability and differential motion with the primary tumor, however, is lacking from large series. In this study, lymph node and tumor position variability were analyzed in detail and correlated to the main carina to evaluate possible margin reduction. Methods and Materials: Small gold fiducial markers (0.35 × 5 mm) were placed in the mediastinal lymph nodes of 51 patients with non-small cell lung cancer during routine diagnostic esophageal or bronchial endoscopic ultrasonography. Four-dimensional (4D) planning computed tomographic (CT) and daily 4D cone beam (CB) CT scans were acquired before and during radical radiation therapy (66 Gy in 24 fractions). Each CBCT was registered in 3-dimensions (bony anatomy) and 4D (tumor, marker, and carina) to the planning CT scan. Subsequently, systematic and random residual misalignments of the time-averaged lymph node and tumor position relative to the bony anatomy and carina were determined. Additionally, tumor and lymph node respiratory amplitude variability was quantified. Finally, required margins were quantified by use of a recipe for dual targets. Results: Relative to the bony anatomy, systematic and random errors ranged from 0.16 to 0.32 cm for the markers and from 0.15 to 0.33 cm for the tumor, but despite similar ranges there was limited correlation (0.17-0.71) owing to differential motion. A large variability in lymph node amplitude between patients was observed, with an average motion of 0.56 cm in the cranial-caudal direction. Margins could be reduced by 10% (left-right), 27% (cranial-caudal), and 10% (anteroposterior) for the lymph nodes and −2%, 15%, and 7% for the tumor if an online carina registration protocol replaced a protocol based on bony anatomy registration. Conclusions: Detailed analysis revealed considerable lymph node position variability, differential motion, and respiratory motion. Planning target volume margins can be reduced up to 27% in lung cancer patients when the carina registration replaces bony anatomy registration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Experience and Evaluation of Patient Treatment Verification With a Transit Dosimeter

Purpose: To prospectively evaluate a protocol for transit dosimetry on a patient population undergoing intensity modulated radiation therapy (IMRT) and to assess the issues in clinical implementation of electronic portal imaging devices (EPIDs) for treatment verification. Methods and Materials: Fifty-eight patients were enrolled in the study. Amorphous silicon EPIDs were calibrated for dose and used to acquire images of delivered fields. Measured EPID dose maps were back-projected using the planning computed tomographic (CT) images to calculate dose at prespecified points within the patient and compared with treatment planning system dose offline using point dose difference and point γ analysis. The deviation of the results was used to inform future action levels. Results: Two hundred twenty-five transit images were analyzed, composed of breast, prostate, and head and neck IMRT fields. Patient measurements demonstrated the potential of the dose verification protocol to model dose well under complex conditions: 83.8% of all delivered beams achieved the initial set tolerance level of Δ{sub D} of 0 ± 5 cGy or %Δ{sub D} of 0% ± 5%. Importantly, the protocol was also sensitive to anatomic changes and spotted that 3 patients from 20 measured prostate patients had undergone anatomic change in comparison with the planning CT. Patient data suggested an EPID-reconstructed versus treatment planning system dose difference action level of 0% ± 7% for breast fields. Asymmetric action levels were more appropriate for inversed IMRT fields, using absolute dose difference (−2 ± 5 cGy) or summed field percentage dose difference (−6% ± 7%). Conclusions: The in vivo dose verification method was easy to use and simple to implement, and it could detect patient anatomic changes that impacted dose delivery. The system required no extra dose to the patient or treatment time delay and so could be used throughout the course of treatment to identify and limit systematic and random errors in dose delivery for patient groups.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stochastic solution of population balance equations for reactor networks

This work presents a sequential modular approach to solve a generic network of reactors with a population balance model using a stochastic numerical method. Full-coupling to the gas-phase is achieved through operator-splitting. The convergence of the stochastic particle algorithm in test networks is evaluated as a function of network size, recycle fraction and numerical parameters. These test cases are used to identify methods through which systematic and statistical error may be reduced, including by use of stochastic weighted algorithms. The optimal algorithm was subsequently used to solve a one-dimensional example of silicon nanoparticle synthesis using a multivariate particle model. This example demonstrated the power of stochastic methods in resolving particle structure by investigating the transient and spatial evolution of primary polydispersity, degree of sintering and TEM-style images. Highlights: •An algorithm is presented to solve reactor networks with a population balance model. •A stochastic method is used to solve the population balance equations. •The convergence and efficiency of the reported algorithms are evaluated. •The algorithm is applied to simulate silicon nanoparticle synthesis in a 1D reactor. •Particle structure is reported as a function of reactor length and time.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Best practices in evaluation of the magnetocaloric effect from bulk magnetization measurements

Conventional magnetometry is irreplaceable in evaluating bulk magnetization of materials over broad temperature and field ranges. The technique is also effective in quantifying hysteresis that may be associated with magnetic and structural phase transitions that occur during the magnetizing/demagnetizing cycling, and the derived magnetic field-induced isothermal entropy change – one of the most important properties in the field of magnetocalorics. Both systematic and random errors present during the measurements of magnetization, however, may lead to erroneous conclusions. Using two well-known materials – elemental Gd and intermetallic Gd 5 Si 2 Ge 2 as examples, we consider best practices in performing reliable and rapid magnetization measurements for proper characterization of magnetocaloric properties.

36 MATERIALS SCIENCE↗

A Practical Approach to Wave Function Propagation, Hopping Probabilities, and Time Steps in Surface Hopping Calculations

We compare several established approaches for propagating wave functions and calculating hopping probabilities within the fewest switches surface hopping (FSSH) algorithm for difficult cases with many electronic states and many trivial crossings. If only a single time step (Δt c ) is employed, we find that no published approach can accurately capture the dynamics correctly unless Δt c → 0 (which is not computationally feasible). If multiple time steps are employed, for a fixed classical time step (Δt c ), a robust scheme can be found for dynamically choosing quantum time steps (δt q1 and δt q2 ) and calculating hopping probabilities so that one can systematically reduce all errors and achieve maximally efficient accuracy; scattering calculations confirm that one can choose a fairly large classical time step. Furthermore, the robust scheme presented here uses both the “local diabatic” and adiabatic interpolation and thus borrows elements from both the Granucci/Persico and Meek/Levine algorithms. Our findings should be broadly applicable in the future.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Catalight─An Open-Source Automated Photocatalytic Reactor Package Illustrated through Plasmonic Acetylene Hydrogenation

An open-source and modular Python package, Catalight, is developed and demonstrated to automate (photo)catalysis measurements. (Photo)catalysis experiments require studying several parameters to evaluate performance, including the temperature, gas flow rate and composition, illumination power, and spectral profile. Catalight orchestrates measurements over this complicated parameter space and systematically stores, analyzes, and visualizes the results. To showcase the capabilities of Catalight, we perform an automated apparent activation barrier measurement of acetylene hydrogenation over a plasmonic AuPd catalyst on an Al 2 O 3 support, simultaneously varying laser power, wavelength, and temperature in a multiday experiment controlled by a simple Python script. Our chemical results unexpectedly show an increased activation barrier upon light excitation, contrary to previous findings for other plasmonic reactions and catalysts. We show that the reaction rate order with respect to both acetylene and hydrogen remains unchanged upon illumination, suggesting that molecular surface coverage is not changed by light. By analyzing the inhomogeneity of the laser-induced heating, we attribute these results to a partial photothermal effect combined with a photochemical/hot electron-driven mechanism. In conclusion, our findings highlight the capabilities of a new experiment automation tool; explore the photocatalytic mechanism for an industrially relevant reaction; and identify systematic sources of error in canonical photocatalysis experimental procedures.

Catalysts↗

Determination of the rate constants for the radical-radical reactions NH{sub 2}(X{sup 2}B{sub 1}) + NH(X{sup 3}{Sigma}{sup -}) and NH{sub 2}(X{sup 2}B{sub 1}) + H({sup 2}S{sub u}) at 293 K.

The rate constant for the reactions NH{sub 2}({sub x}{sup 2}B{sub 1}) + NH(X{sup 3}{Sigma}{sup -}) and NH{sub 2}({sub x}{sup 2}B{sub 1}) + H({sup 2}S) were measured over a pressure range from 2 to 10 Torr in CF{sub 4}, or Ar gases at 293 {+-} 2 K. The radicals were produced by the 193 nm photolysis of NH{sub 3} dilute in the carrier gas. Both radicals were monitored simultaneously following the photolysis laser pulse using high-resolution time-resolved absorption spectroscopy. The NH{sub 2} radical was monitored using the {sup 1}2{sub 21} {l_arrow} {sup 1}3{sub 31} rotational transition of the (0,7,0){sub A}{sup 2}A{sub 1} {l_arrow} (0,0,0) {sub x}{sup 2}B{sub 1} vibronic band near 675 nm, and the NH radical was monitored using the {sup 1}R{sub 3}(4) rotational transition on the 1?0 vibrational transition near 3084 nm. The data was analyzed using model simulations of the NH{sub 2} and NH temporal concentration profiles. The rate constants for the NH{sub 2} + NH and NH{sub 2} + H reactions were found to be (9.6 {+-} 3.2) x 10{sup -11} and (7.7 {+-} 14) x 10{sup -15} cm{sup 3} molecule{sup -1} s{sup -1}, respectively, where the uncertainty includes an estimate of both systematic and random errors. The measurements were independent of the nature of the diluents, CF{sub 4} or Ar, and total pressure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗