Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Synchrotrons”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Energy dispersive x-ray diffraction of luminescent powders: A complement to visible phosphor thermometry

Energy-dispersive x-ray diffraction of thermographic phosphors has been explored as a complementary temperature diagnostic to visible phosphor thermometry in environments where the temperature-dependent optical luminescence of the phosphors is occluded. Powder phosphor samples were heated from ambient to 300°C in incremental steps and probed with polychromatic synchrotron x rays; scattered photons were collected at a fixed diffraction angle of 3.9°. Crystal structure, lattice parameters, and coefficients of thermal expansion were calculated from the diffraction data. Finally, of the several phosphors surveyed, YAG:Dy, ZnO:Ga, and GOS:Tb were found to be excellent candidates for diffraction thermometry due to their strong, distinct diffraction peaks that shift in a repeatable and linear manner with temperature.

47 OTHER INSTRUMENTATION↗

Digital autofocusing of a coded-aperture Laue diffraction microscope

To provide optimal depth resolution with a coded-aperture Laue diffraction microscope, an accurate position of the coded-aperture and its scanning geometry need to be known. However, finding the geometry by trial and error is a time-consuming and often challenging process because of the large number of parameters involved. In this paper, we propose an optimization approach to automate the focusing process after data is collected. Here we demonstrate the robustness and efficiency of the proposed approach with experimental data taken at a synchrotron facility.

47 OTHER INSTRUMENTATION↗

Marginal stability constraint on runaway electron distribution

High-frequency kinetic instabilities of the strongly anisotropic runaway electrons (RE) can enhance the pitch-angle scattering of the runaways significantly. This wave-induced scattering can easily prevail over runaway scattering on high-Z impurities. In a steady state, collisional damping balances the kinetic drive of the unstable waves, keeping the RE distribution function at marginal stability. The marginal stability constraint limits the achievable RE densities and the shape of the RE distribution function. In this study, we consider whistler and compressional Alfvén waves as the primary source of enhanced elastic scattering of the runaways. By balancing the anomalous Doppler resonance drive with the collisional wave damping, we find the RE distribution function in the ultra-relativistic range of the phase space. We also derive an expression for the spectral energy density of the waves. We show that the power needed to compensate for the wave dissipation is negligible compared to the work of the electric field. The latter is in balance with the synchrotron losses of the runaway electrons.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nanolamellar phase transition in an additively manufactured eutectic high-entropy alloy under high pressures

Much is unknown about how phase transitions link to micro-/nano-structures in high-entropy systems, especially under extreme pressure and temperature conditions. This work studies the evolution of dual-phase nanolamellar eutectic high-entropy alloy phases of AlCoCrFeNi 2.1 generated by laser powder-bed fusion (L-PBF) for pressures up to 42 GPa. We compare quasi-hydrostatic high pressure synchrotron x-ray diffraction studies on L-PBF printed cylindrical samples up to 5.5 GPa (large-volume Paris–Edinburgh cell) to those carried out on an L-PBF printed foil in a diamond anvil cell where the pressure reached 42 GPa. Our results show that the initially alternating face-centered cubic (FCC) and body-centered cubic (BCC) nanolamellar structure of AlCoCrFeNi 2.1 transformed into single-phase FCC nanolamellae under high pressure with BCC–FCC phase transformation completion at 21 ± 3 GPa. Our results indicate a diffusionless BCC–FCC transformation in this additively manufactured far-from-equilibrium microstructure and demonstrate that the FCC phase is stable up to very high pressures. The measured equation of state for the FCC phase of AlCoCrFeNi 2.1 is presented up to 42 GPa and shows excellent agreement between the data obtained in large-volume press and diamond anvil cell experiments.

36 MATERIALS SCIENCE↗

Flatfielding of hybrid pixel detectors in tender x-ray scattering

The ability of the soft matter interfaces beamline at National Synchrotron Light Source II to access x-ray energy in the tender x-ray regime, i.e., from 2.1 to 5 keV, enables new resonant x-ray scattering studies at the sulfur K-edge and others. We present a new approach to correct data acquired in the tender x-ray regime with a Pilatus3 detector in order to improve the data quality and to correct the various artifacts inherent to hybrid pixel detectors, such as variations in modules’ efficiency or noisy detector module junctions. Further, this new flatfielding significantly enhances the data quality and enables detection of weak scattering signals.

47 OTHER INSTRUMENTATION↗

Structural modulation and spin glassiness upon oxidation in oxygen storage material LnFeMnO 4+x for Ln = Y, Lu, and Yb

The mixed valence multiferroic LnFe 2+ Fe 3+ O 4 (where Ln = Y, Lu, and Yb) can reversibly uptake oxygen into its lattice, which is evidenced by a crystallographic phase transition along with the appearance of structural modulations. In this study, we show that the Mn-substituted version of this multiferroic can also be readily oxidized to LnFe 3+ Mn 3+ O 4.5 revealing similar oxygen storage behavior. Through neutron, electron, and synchrotron x-ray diffraction studies, we observe a structural modulation that we attribute to a displacement wave in the fully oxidized compound. This wave exhibits commensurability with a wavevector q = (-2/7, 1/7, 0). Bond valence summation analysis of plausible interstitial oxygen positions suggests that oxygen insertion likely occurs at the middle of the Fe/Mn–O bipyramid layers. The structural modulation of LnFeMnO 4.5 is two-dimensional, propagates along the ab-plane, and is highly symmetric as 12 identical modulation vectors are observed in the diffraction patterns. The nature of the lanthanide, Ln 3+ , does not seem to influence such modulations since we observe identical satellite reflections for all three samples of Ln = Y, Lu, and Yb. Both LnFeMnO 4 and LnFeMnO 4.5 display spin glassy behavior with 2D short-range magnetic ordering being observed in LnFeMnO 4 . Analysis of the neutron diffraction data reveals a correlation length of ~10 nm. Upon oxidation to LnFeMnO 4.5 , the short-range magnetic order is significantly suppressed.

36 MATERIALS SCIENCE↗

Development of the high energy engineering X-ray (HEX) superconducting wiggler, magnetic measurement, installation, and commissioning

The High energy Engineering X-ray (HEX) diffraction beamline at the National Synchrotron Light Source II (NSLS-II) at Brookhaven National Lab (BNL) is the first high-energy beamline capable of reaching 200 keV for a monochromatic beam. With the 3 GeV electron beam energy for the NSLS-II ring, only the superconducting wiggler (SCW) producing greater than 4 T peak field can cover these ranges with a sufficient number of photons. The 1.2 m-long HEX-SCW has a period length of 70 mm and a field strength on-axis of 4.3 T. It utilizes no liquid helium, and the vertical aperture size of the electron beam vacuum chamber is 8 mm. Unlike regular undulators/wigglers, there is no standard configuration for the magnetic measurement system for superconducting insertion devices. The NSLS-II Insertion Devices group has developed, in collaboration with the vacuum group, a novel in-vacuum Hall mapper with a 1.75 m in-vacuum linear motor and an in-vacuum flip coil system utilizing many commercial-off-the-shelf products. The measurements were conducted at the BNL, and the device was installed in the ring and commissioned. Here, this paper provides a description of the SCW and its magnetic measurement systems, as well as a brief account of the installation and commissioning efforts.

36 MATERIALS SCIENCE↗

Study of perovskite CsPbBr 3 detector polarization and its mitigation with ultrahigh x-ray flux

High-flux capable semiconductor x-ray detectors are essential in various applications, but the detrimental effects of detector polarization limit their use in many cases. Here, for this work, we studied the polarization of perovskite CsPbBr 3 semiconductor detectors using ultrahigh flux synchrotron x rays (10 6 –10 12 photons s –1 mm –2 at 58.61 keV). The CsPbBr 3 detectors did not show immediate polarization prominently until a flux higher than 10 10 photons s –1 mm –2 . Using the pump-and-probe technique, we visualized the spatial and temporal effects of polarization. The polarized region, represented by reduced photocurrent, extended beyond the area under direct irradiation, and the reduced photocurrent persisted after potential de-polarization treatments. We found that stronger applied electric fields and fewer carrier traps can mitigate polarization, represented by less photocurrent deficit. By examining the detectors’ current response under controlled ambient light, low, and high-flux x rays, we studied the trap filling and release behavior of CsPbBr 3 . We discovered that the polarization is caused by partial detector damage due to deep defects generated by ultrahigh flux x-ray irradiation. Our work provides insight into CsPbBr 3 polarization under extremely intense x-ray radiation and shows that reducing crystal defects and increasing detector bias voltage are effective solutions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Compact, portable, automatic sample changer stick for cryostats and closed-cycle refrigerators

Beamlines are facilities that produce and deliver highly focused and intense beams of radiation, typically x rays, synchrotron radiation, or neutrons, for scientific research purposes. Millions of dollars are spent annually to maintain and operate these scientific beamlines, oftentimes running continuously between cycles. To reduce human intervention and improve productivity, mechanical sample changers are often commissioned for use. Designing sample changers is difficult because mechanical parts can be bulky, expensive, and challenging to design for instruments with low volume access, high radiation, and cryogenic environments. We present a portable and inexpensive sample changer stick that can hold and manipulate up to four samples, specifically designed for use with cryogenic closed-cycle refrigerators. The sample changer stick enables rapid and efficient exchange of samples without manual intervention, and is compatible with standard sample mounts such as vanadium cans. The sample changer stick includes a motorized rotation and lancing mechanism, which enables the precise positioning of each sample in the neutron beam, while ensuring compatibility with the operating temperatures and vacuum conditions required for closed-cycle refrigerators. The design has been successfully tested at the VISION beamline at the Spallation Neutron Source. The mechanical action and software controls are detailed. Furthermore, the sample changer stick is a valuable tool for scientists working with cryogenic closed-cycle refrigerators.

36 MATERIALS SCIENCE↗

In situ spin coater for multimodal grazing incidence x-ray scattering studies

We present herein a custom-made, in situ, multimodal spin coater system with an integrated heating stage that can be programmed with spinning and heating recipes and that is coupled with synchrotron-based, grazing-incidence wide- and small-angle x-ray scattering. The spin coating system features an adaptable experimental chamber, with the ability to house multiple ancillary probes such as photoluminescence and visible optical cameras, to allow for true multimodal characterization and correlated data analysis. This system enables monitoring of structural evolutions such as perovskite crystallization and polymer self-assembly across a broad length scale (2 Å–150 nm) with millisecond temporal resolution throughout a complete thin film fabrication process. The use of this spin coating system allows scientists to gain a deeper understanding of temporal processes of a material system, to develop ideal conditions for thin film manufacturing.

47 OTHER INSTRUMENTATION↗

Response of ZrC to swift heavy ion irradiation

Zirconium carbide (ZrC) is commonly used for energy sector research, as well as a surrogate for the proposed advanced nuclear fuel candidate uranium carbide. Here this study investigates structural modifications to nanocrystalline and microcrystalline ZrC resulting from dense electronic excitations induced by swift heavy ion exposure. Samples were irradiated with 946 MeV Au ions to various fluences up to 6 × 10 13 ions cm –2 and characterized using synchrotron-based x-ray diffraction. The evolution of the unit-cell parameter and heterogeneous microstrain were evaluated as a function of fluence and compared with those of nanocrystalline and microcrystalline CeO 2 (a surrogate for UO 2 fuel) irradiated under identical conditions. Distinct differences were observed in the radiation responses of the carbide and oxide across both grain sizes. Most notably, microcrystalline ZrC exhibits swelling characterized by two distinct regimes, which does not result in saturation at the ion fluences achieved. This contrasts with CeO 2 , which exhibits the well-documented direct-impact defect accumulation mechanism, reaching a steady-state saturation of swelling at higher fluences. Nanocrystalline CeO 2 undergoes more pronounced swelling compared with microcrystalline CeO 2 , in contrast to nanocrystalline ZrC, which exhibits only minimal unit-cell changes. These results demonstrate that swift heavy ion-induced structural changes can be quite different in carbides and oxides, which must be considered when extrapolating fission-fragment type damage in current fuels to advanced fuels.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Simultaneous measurements of volume, pressure, optical images, and crystal structure with a dynamic diamond anvil cell: A real-time event monitoring system

The dynamic diamond anvil cell (dDAC) technique has attracted great interest because it possibly provides a bridge between static and dynamic compression studies with fast, repeatable, and controllable compression rates. The dDAC can be a particularly useful tool to study the pathways and kinetics of phase transitions under dynamic pressurization if simultaneous measurements of physical quantities are possible as a function of time. We report the development of a real-time event monitoring (RTEM) system with dDAC, which can simultaneously record the volume, pressure, optical image, and structure of materials during dynamic compression runs. In particular, the volume measurement using both Fabry–Pérot interferogram and optical images facilitates the construction of an equation of state (EoS) using the dDAC in a home-laboratory. We also developed an in-line ruby pressure measurement (IRPM) system to be deployed at a synchrotron x-ray facility. This system provides simultaneous measurements of pressure and x-ray diffraction in low and narrow pressure ranges. The EoSs of ice VI obtained from the RTEM and the x-ray diffraction data with the IRPM are consistent with each other. The complementarity of both RTEM and IRPM systems will provide a great opportunity to scrutinize the detailed kinetic pathways of phase transitions using dDAC.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

New dynamic diamond anvil cell for time-resolved radial x-ray diffraction

The dynamic diamond anvil cell (dDAC) is a recently developed experimental platform that has shown promise for studying the behavior of materials at strain rates ranging from intermediate to quasi-static and shock compression regimes. Combining dDAC with time-resolved x-ray diffraction (XRD) in the radial geometry (i.e., with incident x-rays perpendicular to the axis of compression) enables the study of material properties such as strength, texture evolution, and deformation mechanisms. This work describes a radial XRD dDAC setup at beamline P02.2 (Extreme Conditions Beamline) at DESY’s PETRA III synchrotron. Time-resolved radial XRD data are collected for titanium, zirconium, and zircon samples, demonstrating the ability to study the strength and texture of materials at compression rates above 300 GPa/s. In addition, the simultaneous optical imaging of the DAC sample chamber is demonstrated. The ability to conduct simultaneous radial XRD and optical imaging provides the opportunity to characterize plastic strain and deviatoric strain rates in the DAC at intermediate rates, exploring the strength and deformation mechanisms of materials in this regime.

47 OTHER INSTRUMENTATION↗

Static and shock compression studies of eutectic high-entropy alloy AlCoCrFeNi 2.1 to ultrahigh pressures

The high-entropy alloy with composition AlCoCrFeNi 2.1 , additively manufactured with the laser powder-bed fusion technique, has a far-from-equilibrium BCC/FCC eutectic nanolamellar structure. We studied the high-pressure response of this alloy under both static compression and high-strain rate shock compression. The response to static compression using a diamond anvil cell was studied at pressures up to 302 GPa with synchrotron x-ray diffraction at the advanced photon source. The high-pressure FCC-only phase of the EHEA previously observed by Pope et al. [AIP Adv. 13, 035124 (2023)] is found to be stable up to the highest pressure achieved in this study with a volume compression of V/V 0 = 0.587 at ambient temperature. The shock experiments were performed by using GEKKO XII lasers at the Institute of Laser Engineering, Osaka University. The principal Hugoniot equation-of-state of the EHEA was measured up to a pressure of 515 GPa and a compression of V/V 0 = 0.613. Additionally, the thermal equation of state of the EHEA was measured up to 6.2 GPa and 1623 K using a large-volume Paris–Edinburgh cell to obtain the temperature dependence of bulk modulus and thermal expansion coefficients. The melting temperature for EHEA AlCoCrFeNi 2.1 at a pressure of 5.6 GPa was measured to be 1648 ± 25 K. These results can be used to refine stochastic (or special) quasi-random structure (SQS) models for high-pressure high-temperature behavior of high-entropy alloys.

36 MATERIALS SCIENCE↗

In situ x-ray imaging to understand subsurface behavior during continuous wave laser drilling

A limited understanding regarding the underlying dynamics and mechanisms of material removal during continuous wave laser drilling has presented significant challenges in achieving precision and process control. Here, to address this, we employed high-fidelity, in situ synchrotron x-ray imaging to reveal previously unknown material behaviors during continuous wave laser drilling with power modulation. Our findings highlight that high-aspect ratio drill holes are achieved when the laser modulation frequency falls within the range of 8–12 kHz, provided that the laser average power and modulation amplitude levels meet the specified limits. Under these conditions, we identified a material removal mechanism driven by incremental accumulation of recoil pressure that gradually pushes material upward from deep within the substrate to the surface. This mechanism manifested as a low-frequency fluctuation in the vapor depression depth, resulting in periodic instances of material ejection. Furthermore, our study underscores that rapid expansion of the melt pool and the widening of the drill hole opening can impede effective material removal by redirecting energy from material ejection to increasing the melt pool size. This investigation contributes essential insights into the subsurface dynamics involved in the drilling of high-aspect ratio holes, furthering our fundamental understanding of this intricate process.

47 OTHER INSTRUMENTATION↗

Improvements to the characterization of Agfa x-ray film for use on opacity spectroscopy diagnostics

The National Ignition Facility uses a soft x-ray opacity spectrometer for x-ray spectral imaging in high-energy-density experiments. The increased demand for a better spectral resolution prompted the investigation into the Agfa D4 film. Characterization is already under way for the film. A Manson x-ray source using six different anodes was used to expose film to the linear optical density (OD) region. This is a continuation of the previous work, and the updated analysis process is communicated here. The identified uncertainties have been reduced with the updated steps that improve the results of the characterization process. In conclusion, when the Stanford Synchrotron Radiation Lightsource Beamline 16-2 was operational, the film was characterized at that source. Its beam offered a higher fluency with a lower exposure time needed to reach saturation. Results for both sources are compared in this paper.

47 OTHER INSTRUMENTATION↗

Interface instabilities in hafnium hydride entrained iron metal matrix composites

The chemical interactions in Fe–HfH 2 metal matrix composites (MMCs) are studied across multiple length scales to elucidate the decomposition of the parent phases and corresponding reaction zone physics during direct current sintering. Fe–HfH 2 composites were synthesized with increasing as-mixed hydride contents of Fe–25% HfH 2 , Fe–40% HfH 2 , Fe–55% HfH 2 , and Fe–70% HfH 2 (all in vol. %) to demonstrate the ability to achieve sintered MMCs with target hydride contents. Samples were probed across multiple length scales through a multi-modal workflow employing x-ray diffraction, scanning electron microscopy and segmentation analysis, and synchrotron techniques including hard x-ray fluorescence mapping and nanoprobe x-ray absorption near-edge structure measurements. Under the selected sintering temperature and pressure conditions, hydrogen evolution is seen to evolve through parallel paths: thermal decomposition from during the transformation of HfH 2 to HfH x<2 and through subsequent reaction with the Fe matrix leading to intermetallic phase formation. Specifically, HfFe and HfFe 2 intermetallic formation accelerates the release of hydrogen with a subsequent HfO 2 phase forming at grain boundaries. For this MMC, the consumption or loss of hydrogen can be considerable in compacts with initial hydride loading of 25%–40% HfH 2 approaching 83% hydrogen loss for the lower volume fraction composites. Increasing the volume fraction of HfH 2 to 70% enhanced the retained hydrogen content to 53% and attributed to the reduced interfacial area intrinsic to the increased HfH 2 loading in this MMC.

36 MATERIALS SCIENCE↗

Optical design and efficiency measurement of an extreme ultraviolet high-resolution spectrometer for unresolved transition array research

Understanding the structures of the unresolved transition array (UTA) observed in extreme ultraviolet (EUV) spectra from many-electron atoms is crucial for various applications, including fusion science and nanolithography. Here, to measure the fine structure of the UTA from tungsten and tin at around 5 and 13.5 nm at the Tokyo electron beam ion trap, we developed a high-resolution EUV spectrometer. The designed spectrometer achieves a resolving power of λ/dλ > 5000 at 5 and 13.5 nm. The fabricated large-area grating was experimentally examined at beamline BL5B of the UVSOR synchrotron facility to evaluate the diffraction efficiencies and their variation across the ruled area. The measured diffraction efficiencies are 0.65% ± 0.07% at 5 nm (second order) and 7.9% ± 0.2% at 13.5 nm (first order). The variation in the diffraction efficiency across the ruled area is 2.2%, 13.6%, and 10.0% in zeroth, first, and second order diffractions, respectively. The discrepancies in diffraction efficiencies between the experiments and the calculations were 5.2%, 29%, and 35% for the zeroth, first, and second diffraction orders, respectively.

47 OTHER INSTRUMENTATION↗