Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Development of an L-Edge X-ray Absorbance Spectrometer for Monitoring Dissolver Solutions in H-Canyon

Savannah River National Laboratory has developed a monitor to measure plutonium and uranium concentrations in solutions of dissolved nuclear fuel. The monitor will be installed in the sample aisle location for the 6.3D Dissolver in the Savannah River Site’s H-Canyon and used in support of the electrolytic dissolution such as Fast Critical Assembly fuel. The monitor is based on the atomic absorbance of x-rays. Elements are differentiated by the appearance of absorbance features at specific energies of the x-ray spectrum that correspond to L-edge transitions of inner core electrons. Hence, the technique is called L-Edge X-Ray Absorbance Spectroscopy (L-XRAS). The technique is suitable for nuclear fuel processing due to its relative insensitivity to other components of the dissolver solution, such as nitric acid, transition metals (Fe, Cr, Ni, Mn) such as those from stainless steel, particulates, and catalysts and additives. The instrumentation consists of a commercially available x-ray source and detector, a sample cell designed to interface with the airlift sampler associated with H-Canyon Tank 6.3D, and a stainless steel enclosure. SRNL wrote instrument control software and developed chemometric models to interpret x-ray intensity spectra and estimate analyte concentrations and uncertainties in real time.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Developing an-In-Field Alpha Spectrometer (IFAS)-for UF 6 Enrichment Measurement [Slides]

This project is developing an in-field alpha spectrometry system for the purpose of assaying grab samples of uranium hexafluoride (UF 6 ) and determining uranium enrichment. This new system will accommodate Single-Use Destructive Assay (SUDA) samples (PNNL) and will be robust to handle elevated beta-decay radiation present in UF 6 samples.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Spectral Flux Measurements on SNS Direct Geometry Spectrometers at IRP-2 End-of-Life

The Inner Reflector Plug (IRP) of the Spallation Neutron Source (SNS) was replaced during the SNS shutdown period beginning 25 November 2025. This IRP, IRP-2, was first placed in service in May 2018, and was in use for 42.5 GW-hrs of operation, somewhat longer than its original design life of 30 GW-hrs, or even a refined estimate of 33 GW-hrs for the water moderator poison plate and 39 GW-hrs on the decoupled-poisoned hydrogen moderator decoupler (Gallmeier, Lu, and Iverson 2018). The time-integrated power history for IRP-2 is tracked in Figure 1.

43 PARTICLE ACCELERATORS↗

A Very Forward Hadron Spectrometer for the LHC and Cosmic Ray Physics

Charged hadron production in hadron-hadron collisions with longitudinal momentum fraction Feynman-x, x_F, between 0.1 and 0.9 has not been measured above square root s = 63 GeV at the CERN Intersecting Storage Rings. I discuss a way to measure this at the Large Hadron Collider at square root s = 13 TeV, which is 40,000 times higher in equivalent fixed target energy, and important for understanding cosmic ray showers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of the Orbital Modulation of Fe Kα Fluorescence Emission in Centaurus X-3 Using the High-resolution Spectrometer Resolve on board XRISM

Abstract The Fe K α fluorescence line emission in X-ray spectra is a powerful diagnostic tool for various astrophysical objects to reveal the distribution of cold matter around photoionizing sources. The advent of the X-ray microcalorimeter on board the XRISM satellite will bring new constraints on the emission line. We present one of the first such results for the high-mass X-ray binary Centaurus X-3, which is composed of an O-type star and a neutron star (NS). We conducted a 155 ks observation covering an entire binary orbit. A weak Fe K α line was detected in all orbital phases at an equivalent width (EW) of 10–20 eV. We found for the first time that its radial velocity (RV) is sinusoidally modulated by the orbital phase. The RV amplitude is 248 ± 13 km s −1 , which is significantly smaller than the value (391 km s −1 ) expected if the emission is from the NS surface, but is consistent if the emission takes place at the O star surface. We discuss several possibilities of the line production site, including the NS surface, O star surface, O star wind, and accretion stream from the O star to the NS. We ran radiative transfer calculation for some of them assuming spherically symmetric density and velocity profiles and an isotropic distribution of X-ray emission from the NS. None of them explains the observed EW and velocity dispersion dependence on the orbital phase, suggesting that more elaborated modeling is needed. In other words, the present observational results have the capability to constrain deviations from these assumptions.

High energy astrophysics↗

Intercomparison of open-path trace gas measurements with two dual-frequency-comb spectrometers

Abstract. We present the first quantitative intercomparison between two open-path dual-comb spectroscopy (DCS) instruments which were operated across adjacent 2 km open-air paths over a 2-week period. We used DCS to measure the atmospheric absorption spectrum in the near infrared from 6023 to 6376 cm−1 (1568 to 1660 nm), corresponding to a 355 cm−1 bandwidth, at 0.0067 cm−1 sample spacing. The measured absorption spectra agree with each other to within 5 × 10−4 in absorbance without any external calibration of either instrument. The absorption spectra are fit to retrieve path-integrated concentrations for carbon dioxide (CO2), methane (CH4), water (H2O), and deuterated water (HDO). The retrieved dry mole fractions agree to 0.14 % (0.57 ppm) for CO2, 0.35 % (7 ppb) for CH4, and 0.40 % (36 ppm) for H2O at ∼ 30 s integration time over the 2-week measurement campaign, which included 24 °C outdoor temperature variations and periods of strong atmospheric turbulence. This agreement is at least an order of magnitude better than conventional active-source open-path instrument intercomparisons and is particularly relevant to future regional flux measurements as it allows accurate comparisons of open-path DCS data across locations and time. We additionally compare the open-path DCS retrievals to a World Meteorological Organization (WMO)-calibrated cavity ring-down point sensor located along the path with good agreement. Short-term and long-term differences between the open-path DCS and point sensor are attributed, respectively, to spatial sampling discrepancies and to inaccuracies in the current spectral database used to fit the DCS data. Finally, the 2-week measurement campaign yields diurnal cycles of CO2 and CH4 that are consistent with the presence of local sources of CO2 and absence of local sources of CH4.

Waxman, Eleanor M.↗

Development and field testing of a rapid and ultra-stable atmospheric carbon dioxide spectrometer

We present field test results for a new spectroscopic instrument to measure atmospheric carbon dioxide (CO 2 ) with high precision (0.02 μmol mol -1 , or ppm at 1 Hz) and demonstrate high stability (within 0.1 ppm over more than 8 months), without the need for hourly, daily, or even monthly calibration against high-pressure gas cylinders. The technical novelty of this instrument (ABsolute Carbon dioxide, ABC) is the spectral null method using an internal quartz reference cell with known CO 2 column density. Compared to a previously described prototype, the field instrument has better stability and benefits from more precise thermal control of the optics and more accurate pressure measurements in the sample cell (at the mTorr level). The instrument has been deployed at a long-term ecological research site (the Harvard Forest, USA), where it has measured for 8 months without on-site calibration and with minimal maintenance, showing drift bounds of less than 0.1 ppm. Field measurements agree well with those of a commercially available cavity ring-down CO 2 instrument (Picarro G2301) run with a standard calibration protocol. This field test demonstrates that ABC is capable of performing high-accuracy, unattended, continuous field measurements with minimal use of reference gas cylinders.

Xiang, B.↗