High-bandwidth frequency domain multiplexed readout of transition-edge sensors for neutrinoless double beta decay searches

The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at ∼ 10 mK, are usually read out by high-impedance neutron transmutation doped (NTD) thermistors, which provide good energy resolution, but are limited by ∼ 1 ms response times. Superconducting detectors, such as transition-edge sensors (TESs) with a time resolution of ∼ 100 μs, offer superior timing performance over NTD semiconductor bolometers. To make this technology viable for an application to a thousand or more channels, multiplexed readout is necessary in order to minimize the thermal load and radioactive contamination induced by the readout. Frequency-domain multiplexing readout (fMUX) for TESs, previously developed at Berkeley Lab and McGill University, is currently in use for mm-wave telescopes with detector sampling rates in the order of 100 Hz. We demonstrate a new readout system, based on the McGill/Berkeley digital fMux readout, to satisfy the higher bandwidth and noise requirements of the next generation of TES-instrumented cryogenic calorimeters. Each multiplexing readout module comprises 10 superconducting resonators in the 1–5 MHz range and a DC superconducting quantum interference device (DC-SQUID), interfaced to high-speed field programmable gate array (FPGA)-based electronics for digital signal processing and low-latency SQUID feedback. The new readout samples detectors at 156 kHz, three orders of magnitude faster than its cosmology-oriented predecessor, and demonstrates a stable feedback bandwidth of 3 kHz in a real TES-based system.

47 OTHER INSTRUMENTATION↗

Calibration, Reconstruction, and Rendering of Cylindrical Millimeter-Wave Image Data

Cylindrical millimeter-wave imaging systems and technology have been under development at the Pacific Northwest National Laboratory for many years. This technology has been commercialized, and systems are currently being deployed widely across the United States and internationally. These systems are effective at screening for concealed items of all types, however, new sensor designs, image reconstruction techniques, and image rendering algorithms, could potentially improve performance. At PNNL, a number of specific techniques have been developed recently to improve cylindrical imaging methods including wideband techniques, combining data from full 360 degree scans, polarimetric imaging techniques, calibration methods, and 3-D data visualization techniques. Many of these techniques exploit the three-dimensionality of the cylindrical imaging technique by optimizing the depth resolution of the system and using this information to enhance detection. Other techniques, such as polarimetric methods, exploit scattering physics of the millimeter-wave interaction with concealed targets on the body. In this paper, calibration, reconstruction, and three-dimensional rendering techniques will be described that optimize the depth information in these images and the display of the images to the operator.

concealed-weapon detection↗

Hurtado summer 2025 REDWOODS PWFS code

This release includes code developed by Benjamin Gerard and Joel Hurtado in summer 2025 to model the performance of different modes of the reflective three-sided pyramid wavefront sensor instrument within the REDWOODS module of the Shane Adaptive Optics system at Lick observatory.

Gerard, BenjaminL [Lawrence Livermore National Lab↗

Post-Closure Inspection and Monitoring Report for Corrective Action Unit 417: Central Nevada Test Area Surface, Hot Creek Valley, Nevada

This report presents results of data collected during the annual post-closure site inspections conducted at the Central Nevada Test Area surface Corrective Action Unit (CAU) 417 in May 2011 and July 2012. The annual post-closure site inspections included inspections of the UC-1, UC-3, and UC-4 sites in accordance with the Post-Closure Monitoring Plan provided in the CAU 417 Closure Report (NNSA/NV 2001). The annual inspections conducted at the UC-1 Central Mud Pit (CMP) indicated that the site and soil cover were in good condition. No new fractures or extension of existing fractures were observed and no issues with the fence or gate were identified. The vegetation on the cover continues to look healthy, but the biennial vegetation survey conducted during the 2012 inspection indicated that the total foliar cover was slightly higher in 2009 than in 2012. This may be indicative of a decrease in precipitation observed during the 2-year monitoring period. The precipitation totaled 9.9 inches from July 1, 2010, through June 30, 2011, and 5 inches from July 1, 2011, through June 30, 2012. This decrease in precipitation is also evident in the soil moisture data obtained from the time domain reflectometry sensors. Soil moisture content data show that the UC-1 cover is performing as designed, and evapotranspiration is effectively removing water from the cover.

54 ENVIRONMENTAL SCIENCES↗

Connecticut Biodiesel Power Generation Project

Sabre will continue support of the emissions equipment and VARS issues to ensure all are resolved and the system is functioning as expected. The remote data collection to become more automated. Final project reports for data collection and system performance to be generated. Sabre continued to support the emissions equipment and VARS issues to ensure all are resolved and the system is functioning as expected. The remote data collection became more automated. Final project reports for data collection and system performance were generated and are part of this final report. Some Systems Sensors were replaced due to a lightning strike. Sample data charts are shown at the end of the report. During the project, Sabre Engineering provided support to the project team with regarding to troubleshooting technical issues and system integration with the local power utility company. The resulting lessons learned through Sabre’s participation in the project have been valuable to the integrity of the data collected as well as in providing BioPur Light & Power valuable insights into future operations and planning for possible expansion. The system monitoring and data collection system has been operating as designed and continues to provide relevant information to the system operators. The information routinely gathered automatically by the system also contributes to the REN and REC validations which are required to secure credit for these items. During the quarter, the remaining work on the operations and safety manual were completed and released for publication after screen shots were verified. The goal of this effort to provide an accurate set of precautions and procedures for the technology system that can be replicated to other similar system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fundamental Piezotronic and Piezo-phototronic Effects in Nanowires

The piezo-phototronic effect is about the use of the piezoelectric potential created inside some materials for enhancing the charge carrier generation or separation at the metal-semiconductor contact or p-n junction. We demonstrate the impact of the piezo-phototronic effect on the photon sensitivity for a ZnO-CdS core-shell micro/nanowire based visible and UVsensor. CdS nanowire arrays were grown on the surface of a ZnO micro/nanowire to form a ZnO-CdS core-shell nanostructure by a facile hydrothermal method. With the two ends of a ZnO-CdS wire bonded on a polymer substrate, a flexible photodetector was fabricated, which is sensitive simultaneously to both green light (548 nm) and UV light (372 nm). The photocurrent and sensitivity of the ZnO_CdS wire photodetector is 103 times higher than that of CdS nanoribbon, and the responsivity (11 A W -1 , 548 nm, at 2 V bias) is nearly 100 times higher than that of ZnSe-nanobelt-based blue/UV-light sensor (0.12 AW -1 , 400 nm, at 30 V bias). Moreover, the performance of the ZnO-CdS wire photodetector upon illumination of visible and UV light can be both further enhanced for more than 10 times with the participation of the piezo-phototronic effect when the device is subjected to a -0.31% compressive strain. This investigation extends the application of the piezo-phototronic effect in a wide spectrum photon detector.

14 SOLAR ENERGY↗

Precision Timing in CMS at the HL-LHC: Current Progress on Validation and Production

During the High Luminosity phase of LHC, up to 200 proton-proton collisions per bunch crossing will bring severe challenges for event reconstruction. To mitigate pileup effects, an extended upgrade program of the CMS experiment is expected. Among which, a new timing layer, the MIP Timing Detector (MTD), will be integrated between the tracker and the calorimeters. With a time resolution of 30-60 ps, the MTD will enable 4D vertexing, bringing significant improvements in track-to-vertex association and object identification. The MTD is composed of two subsystems based on different technologies: the Barrel Timing Layer (BTL) consists of LYSO:Ce scintillating crystals readout by SiPMs, and the Endcap Timing Layer (ETL) is made of Low-Gain Avalanche Diodes. The BTL is currently under production, while ETL sensor prototyping and validation are ongoing. Recent system tests have confirmed the performance of the full acquisition chain. This talk will provide an overview of the MTD design, along with the physics motivation, and the current status of BTL construction and ETL development.

Safdari, Murtaza [Fermilab] (ORCID:000000018323731↗

Active Optical Control with Machine Learning: A Proof of Concept for the Vera C. Rubin Observatory

Abstract The Active Optics System of the Vera C. Rubin Observatory (Rubin) uses information provided by four wave front sensors to determine deviations between the reconstructed wave front and the ideal wave front. The observed deviations are used to adjust the control parameters of the optical system to maintain image quality across the 3.°5 field of view. The baseline approach from the project is to obtain amplitudes of the Zernike polynomials describing the distorted wave front from out-of-focus images collected by the wave front sensors. These Zernike amplitudes are related via an “influence matrix” to the control parameters necessary to correct the wave front. In this paper, we use deep-learning methods to extract the control parameters directly from the images captured by the wave front sensors. Our neural net model uses anti-aliasing pooling to boost performance, and a domain-specific loss function to aid learning and generalization. The accuracy of the control parameters derived from our model exceeds Rubin requirements even in the presence of full-moon background levels and mis-centering of reference stars. Although the training process is time consuming, model evaluation requires only a few milliseconds. This low latency should allow for the correction of the optical configuration during the readout and slew interval between successive exposures.

Astronomy & Astrophysics↗

Forced Diffusion Chamber Monitoring of Soil CO2 Fluxes from 2019 to Present at NGEE Arctic Teller Site, Mile Marker 27, Alaska

Soil CO2 efflux was monitored at the NGEE Arctic Teller Site, Mile Marker 27, in Alaska. Monitoring was performed beginning in June 2019 using EOSense forced diffusion soil CO2 flux sensors at up to six sites characterized by varying vegetation cover, topographic position, and soil temperature and moisture. Dataset includes measurements of soil CO2 flux and chamber temperature. Time interval between measurements ranges from 5 minutes to 3 hours. Included are EOSense chamber locations as *.kml and *.png files, six *.csv files with measurements, and two *.csv reporting format files.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Autonomous Correction of Sensor Data Applied to Building Technologies Utilizing Statistical Processing Methods

Autonomous detection and correction of potentially missing or corrupt sensor data is a essential concern in building technologies since data availability and correctness is necessary to develop accurate software models for instrumented experiments. Therefore, this paper aims to address this problem by using statistical processing methods including: (1) least squares; (2) maximum likelihood estimation; (3) segmentation averaging; and (4) threshold based techniques. Application of these validation schemes are applied to a subset of data collected from Oak Ridge National Laboratory s (ORNL) ZEBRAlliance research project, which is comprised of four single-family homes in Oak Ridge, TN outfitted with a total of 1,218 sensors. The focus of this paper is on three different types of sensor data: (1) temperature; (2) humidity; and (3) energy consumption. Simulations illustrate the threshold based statistical processing method performed best in predicting temperature, humidity, and energy data.

building technologies.↗

Design, Construction, and Field Validation of a Blown-In Fiberglass Wall System in a Cold, Wet, and Windy Climate

In the Native Village of Tununak, located on Nelson Island in Southwest Alaska,buildings are exposed to wind-driven rain and snow throughout the year. The Cold Climate Housing Research Center (CCHRC) and Knauf Insulation partnered with the community in 2018 to design a residence for a public safety officer. Construction began in fall 2021 and is scheduled to conclude in summer 2022. The house will use integrated trusses with floor, attic, and wall cavities filled with blown-in fiberglass insulation. Hygrothermal models of the building envelope system demonstrate that the high ambient moisture load will wet the outer edges of the insulation annually regardless of the extent and integrity of exterior weather sealing measures; blown-in fiberglass is expected to be more resilient to this wetting than blown-in cellulose. To verify this, researchers will embed temperature, relative humidity, and moisture sensors in the two windward walls of the house to monitor the ability of the blown-in fiberglass insulation to dry out after wetting events that may have occurred during the transport of the insulation to the building site, storage of the insulation on site, construction process, or after installation in the wall. Sensors will remain in place for two years,documenting the wall's performance over time and verifying the design's potential for use in buildings located in climates where the chance for moisture damage is high. Here, we describe the wall system , design criteria, and the results from the hygrothermal modeling. We share details on the monitoring system's components and the planned management and analysis of data. Finally, we explain how the experiences and data from this project will inform future builds in similar locations.

building design↗

Lithium-Ion Battery Diagnostics Using Electrochemical Impedance via Machine-Learning

Diagnosing battery states such as health, state-of-charge, or temperature is crucial for ensuring the safety and reliability of electrochemical energy storage systems. While some states, such as temperature, may be measured using cheap sensors, accurate diagnosis of battery health metrics usually requires time-consuming performance measurements, making them infeasible for use in real-world operation. These health metrics can be measured during lab-testing and then estimated on-line using predictive life models or via state observer algorithms such as Kalman filters, but these predictive methods should be supplemented by actual measurement of battery health whenever possible to ensure reliability. Rapid measurement of battery health may be done by various types of fast diagnostic techniques such as electrochemical impedance spectroscopy (EIS), which can be performed in only a few minutes and require only a fraction of the energy and power needed for a full charge and discharge measurement. But there is a substantial challenge for estimating battery health using EIS data, as EIS is sensitive to cell temperature, state-of-charge, current, and resting time in addition to health. Thus, utilizing EIS data to predict battery capacity requires correcting for all these additional variables, a task that is extremely difficult to handle analytically. This talk utilizes machine-learning methods to estimate the effectiveness of battery capacity prediction from EIS data, leveraging a data set of hundreds of EIS measurements recorded at varying temperature and state-of-charge throughout a 500-day aging study of 32 commercial, large-format NMC-Graphite lithium-ion batteries. Using EIS as input to machine-learning models is complicated by the nonlinear response of impedance to battery health, temperature, and state-of-charge, as well as the collinearity between the impedance response at neighboring frequencies, which can easily lead to overfit models. To train robust models, features from EIS data need to be extracted from the data or some subset of critical frequencies selected. Many approaches for extracting and selecting features from EIS data from electrochemical analysis and machine-learning fields were identified for analysis: using the entire raw spectra; selection of one, two, or many frequencies from the entire spectra; selecting interesting points from the EIS measurement using domain knowledge; fitting EIS with an equivalent-circuit model; calculating statistics on the raw impedance values; and reducing the dimensionality of the data using unsupervised linear (principal component analysis) and non-linear (uniform manifold approximation and projection) methods. These approaches were rigorously compared using a machine-learning pipeline approach, training linear, Gaussian process, and random forest regression models and quantifying performance using cross-validation as well as a held-out test set. An artificial neural network model trained on the raw spectra was also tested. Promising pipelines were fine-tuned via Bayesian hyperparameter optimization using cross-validation loss and training with class-specific weights to counter data set imbalance. The most reliable method for utilizing impedance in this work was the selection of two optimal frequencies through an exhaustive search, resulting in about 2% mean absolute error on test data for both Gaussian process and random forest model architectures. Interrogation of a variety of models reveals critical frequencies of 100 Hz and 103 Hz for this data set, though the optimal set of frequencies is not necessarily intuitive, i.e., the best performing models are not simply those that use impedance at frequencies that have the highest correlation to the relative discharge capacity. The best performing model is an ensemble model, which is able to predict battery capacity with 1.9% mean absolute error for unseen cells using impedance recorded at a variety of temperatures and states-of-charge.

battery↗

New Measurements and Calculations to Characterize the Caliban Pulsed Reactor Cavity Neutron Spectrum by the Foil Activation Method

Caliban is a cylindrical metallic core reactor mainly composed of uranium 235. It is operated by the Criticality and Neutron Science Research Laboratory located at the French Atomic Energy Commission research center in Valduc. As with other fast burst reactors, Caliban is used extensively for determining the responses of electronic parts or other objects and materials to neutron-induced displacements. Therefore, Caliban's irradiation characteristics, and especially its central cavity neutron spectrum, have to be very accurately evaluated. The foil activation method has been used in the past by the Criticality and Neutron Science Research Laboratory to evaluate the neutron spectrum of the different facilities it operated, and in particular to characterize the Caliban cavity spectrum. In order to strengthen and to improve our knowledge of the Caliban cavity neutron spectrum and to reduce the uncertainties associated with the available evaluations, new measurements have been performed on the reactor and interpreted by the foil activation method. A sensor set has been selected to sample adequately the studied spectrum. Experimental measured reaction rates have been compared to the results from UMG spectrum unfolding software and to values obtained with the activation code Fispact. Experimental and simulation results are overall in good agreement, although gaps exist for some sensors. UMG software has also been used to rebuild the Caliban cavity neutron spectrum from activation measurements. For this purpose, a default spectrum is needed, and one has been calculated with the Monte-Carlo transport code Tripoli 4 using the benchmarked Caliban description. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Optimizing probe design for an implantable perfusion and oxygenation sensor

In an effort to develop an implantable optical perfusion and oxygenation sensor, based on multiwavelength reflectance pulse oximetry, we investigate the effect of source detector separation and other source-detector characteristics to optimize the sensor s signal to background ratio using Monte Carlo (MC) based simulations and in vitro phantom studies. Separations in the range 0.45 to 1.25 mm were found to be optimal in the case of a point source. The numerical aperture (NA) of the source had no effect on the collected signal while the widening of the source spatial profile caused a shift in the optimal source-detector separation. Specifically, for a 4.5 mm flat beam and a 2.4 mm 2.5 mm photodetector, the optimal performance was found to be when the source and detector are adjacent to each other. These modeling results were confirmed by data collected from in vitro experiments on a liver phantom perfused with dye solutions mimicking the absorption properties of hemoglobin for different oxygenation states.

59 BASIC BIOLOGICAL SCIENCES↗

A Flexible Framework for Building Occupancy Detection Using Spatiotemporal Pattern Networks: Preprint

This paper presents a reliable, scalable, and transferable framework to predict occupancy in a building utilizing diverse, multi-modal information. We propose a new methodology for learning-driven occupancy detection built on the concepts of probabilistic graphical modeling and observable Markov chain modeling. To capture the relationship between multi-sensor data and occupancy, we propose this Occ-STPN framework that is flexible to support both multivariate and univariate formulations. While the multivariate Occ-STPN performs feature-level fusion of multiple predictors and occupancy time-series data, the univariate Occ-STPN involves decision fusion of occupancy predictions using individual predictors based on a mutual information weighted fusion scheme. We also propose a new metric to evaluate the performance of occupancy prediction algorithms. Two popular datasets are used to validate our approach and demonstrate that our framework is scalable in terms of the number of information sources (e.g., sensors) as well as it is possible to transfer trained models from one building to another without significant reduction in performance. Reliability of the algorithm is also tested by injecting noise into the datasets.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Flexible Framework for Building Occupancy Detection Using Spatiotemporal Pattern Networks

This paper presents a reliable, scalable, and transferable framework to predict occupancy in a building utilizing diverse, multi-modal information. We propose a new methodology for learning-driven occupancy detection built on the concepts of probabilistic graphical modeling and observable Markov chain modeling. To capture the relationship between multi-sensor data and occupancy, we propose this Occ-STPN framework that is flexible to support both multivariate and univariate formulations. While the multivariate Occ-STPN performs feature-level fusion of multiple predictors and occupancy time-series data, the univariate Occ-STPN involves decision fusion of occupancy predictions using individual predictors based on a mutual information weighted fusion scheme. We also propose a new metric to evaluate the performance of occupancy prediction algorithms. Two popular datasets are used to validate our approach and demonstrate that our framework is scalable in terms of the number of information sources (e.g., sensors) as well as it is possible to transfer trained models from one building to another without significant reduction in performance. Reliability of the algorithm is also tested by injecting noise into the datasets.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Test system for charge collection efficiency measurement (SYCOC) for neutron irradiated silicon sensors

One of the constraints in using standard Float Zone silicon layer as base material for tracking in particle physics is its radiation hardness. The detection efficiency is degraded by the introduction of defects in the silicon crystal and charge trapping becomes the main problem. The Charge Collection Efficiency (CCE) is a relevant parameter in order to determine the detection performance of such devices. A state-of-the-art test system named 'Systeme de mesure de collection de charge' (SYCOC) has been developed for the characterization of diode and microstrip silicon sensors before and after irradiation. The system is designed to perform Charge Collection Efficiency (CCE) and Transient Current Technique (TCT) measurements with laser and radioactive sources in a controlled environment. Initial measurements on diodes are presented. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of HPK n + - p planar pixel sensors for the CMS Phase-2 upgrade

To cope with the challenging environment of the planned high luminosity upgrade of the Large Hadron Collider (HL-LHC), scheduled to start operation in 2029, CMS will replace its entire tracking system. The requirements for the tracker are largely determined by the long operation time of 10 years with an instantaneous peak luminosity of up to 7.5 × 10 34 cm –2 s –1 in the ultimate performance scenario. Depending on the radial distance from the interaction point, the silicon sensors will receive a particle fluence corresponding to a non-ionizing energy loss of up to $\Phi_{\text {eq}}$ = 3.5 × 10 16 cm –2 . Here this paper focuses on planar pixel sensor design and qualification up to a fluence of $\Phi_{\text {eq}}$ = 1.4 × 10 16 cm –2 . For the development of appropriate planar pixel sensors an R&D program was initiated, which includes $n^+ -p$ sensors on 150 mm (6”) wafers with an active thickness of 150 μm with pixel sizes of 100 × 25 μm 2 and 50 × 50 μm 2 manufactured by Hamamatsu. Single chip modules with ROC4Sens and RD53A readout chips were made. Irradiation with protons and neutrons, as well was an extensive test beam campaign at DESY were carried out. This paper presents the investigation of various assemblies mainly with ROC4Sens readout chips. It demonstrates that multiple designs fulfill the requirements in terms of breakdown voltage, leakage current and efficiency. The single point resolution for 50 × 50 μm 2 pixels is measured as 4.0 μm for non-irradiated samples, and 6.3 μm after irradiation to $\Phi_{\text {eq}}$ = 7.2 × 10 15 cm –2 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗