Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sample Calculations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Comparison of experimental and calculated attachment rate constants for CFCl3 and CCl4 in the temperature range 294-500 K

Electron-attachment cross sections and rate constants have been measured and calculated for the dissociative attachment processes e + CFCl3 - Cl(-) + CFCl2 and e + CCl4 - Cl(-) + CCl3. Good agreement over the electron-energy range 1-200 meV is found in energy dependence between present calculated cross sections and experimental cross sections at 300 K. The same calculation, with suitable adjustment of thermal populations, was used to calculate electron-attachment rate constants in the range 50-600 K. Experimental rate constants for CFCl3 and CCl4 were measured at temperatures of 294, 404, and 496 K (CFCl3) and 294, 400, and 500 K (CCl4) using the Cavalleri electron-density sampling method. Good agreement is found between present measurements and calculations, poor agreement with flowing-afterglow Langmuir-probe (FALP) data in CFCl3 at the higher temperatures, and reasonable agreement with FALP data for CCl4.

Orient, O. J.↗

Superoxide Radicals in Uranyl Peroxide Solids: Lasting Signatures Identified by Electron Paramagnetic Resonance Spectroscopy

Abstract U(VI) peroxide phases (studtite and meta‐studtite) are found throughout the nuclear fuel cycle and exist as corrosion products in high radiation fields. Peroxides are part of a family of reactive oxygen species (ROS) that include hydroperoxyl and superoxide species and are produced during alpha radiolysis of water. While U(VI) peroxides have been thoroughly investigated, the incorporation and stability of ROS species within studtite have not been validated. In the current study, electron paramagnetic resonance (EPR) spectroscopy was used to identify the presence of free radicals within a series of U(VI) peroxide samples containing depleted, highly enriched, and natural uranium. Density functional theory calculations indicated that the predicted EPR signals matched well with a superoxide (O 2 − ⋅) species incorporated into the studtite structure, confirming the presence of ROS in the material. Further analysis of samples that were synthesized between 1945 and 2023 indicated that there is a correlation between the radical signal and the product of specific activity multiplied by age of the sample.

Scherrer, Sarah K.↗

Superoxide Radicals in Uranyl Peroxide Solids: Lasting Signatures Identified by Electron Paramagnetic Resonance Spectroscopy

Abstract U(VI) peroxide phases (studtite and meta‐studtite) are found throughout the nuclear fuel cycle and exist as corrosion products in high radiation fields. Peroxides are part of a family of reactive oxygen species (ROS) that include hydroperoxyl and superoxide species and are produced during alpha radiolysis of water. While U(VI) peroxides have been thoroughly investigated, the incorporation and stability of ROS species within studtite have not been validated. In the current study, electron paramagnetic resonance (EPR) spectroscopy was used to identify the presence of free radicals within a series of U(VI) peroxide samples containing depleted, highly enriched, and natural uranium. Density functional theory calculations indicated that the predicted EPR signals matched well with a superoxide (O 2 − ⋅) species incorporated into the studtite structure, confirming the presence of ROS in the material. Further analysis of samples that were synthesized between 1945 and 2023 indicated that there is a correlation between the radical signal and the product of specific activity multiplied by age of the sample.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simulation of Galactic Cosmic Rays and Dose-Rate Effects in RITRACKS

The NASA Space Radiation Laboratory (NSRL) facility has been used successfully for many years to generate ion beams for radiation research experiments by NASA investigators. Recently, modifications were made to the beam lines to allow rapid switching between different types of ions and energies, with the aim to simulate the Galactic Cosmic Rays (GCR) environment. As this will be a focus of space radiation research for upcoming years, the stochastic radiation track structure code RITRACKS (Relativistic Ion Tracks) was modified to simulate beams of various ion types and energies during time intervals specified by the user at the microscopic and nanoscopic scales. For example, particle distributions of a mixed 344.1-MeV protons (18.04 cGy) and 950-MeV/n iron (5.64 cGy) beam behind a 20 g/cm(exp 2) aluminum followed by a 10 g/cm(exp 2) polyethylene shield as calculated by the code GEANT4 were used as an input field in RITRACKS. Similarly, modifications were also made to simulate a realistic radiation environment in a spacecraft exposed to GCR by sampling the ion types and energies from particle spectra pre-calculated by the code HZETRN. The newly implemented features allows RITRACKS to generate time-dependent differential and cumulative 3D dose voxel maps. These new capabilities of RITRACKS will be used to investigate dose-rate effects and synergistic interactions of various types of radiations for many end points at the microscopic and nanoscopic scales such as DNA damage and chromosome aberrations.

Plante, Ianik↗

RADIOACTIVE ELEMENTS IN THE STANDARD ATOMIC WEIGHTS TABLE

In the 1949 Report of the Atomic Weights Commission, a series of new elements were added to the Atomic Weights Table. Since these elements had been produced in the laboratory and were not discovered in nature, the atomic weight value of these artificial products would depend upon the production method. Since atomic weight is a property of an element as it occurs in nature, it would be incorrect to assign an atomic weight value to that element. As a result of that discussion, the Commission decided to provide only the mass number of the most stable (or longest-lived) known isotope as the number to be associated with these entries in the Atomic Weights Table. As a function of time, the mass number associated with various elements has changed as longer-lived isotopes of a particular element has been found in nature, or as improved half-life values of an element's isotopes might cause a shift in the longest-lived isotope from one mass to another. In the 1957 Report of the Atomic Weights Commission, it was decided to discontinue the listing of the mass number in the Atomic Weights Table on the grounds that the kind of information supplied by the mass number is inconsistent with the primary purpose of the Table, i.e., to provide accurate values of 'these constants' for use in various chemical calculations. In addition to the Table of Atomic Weights, the Commission included an auxiliary Table of Radioactive Elements for the first time, where the entry would be the isotope of that element which was the most stable, i.e., the one with the longest known half-life. In their 1973 Report, the Commission noted that the users of the main Table of Atomic Weights were dissatisfied with the omission of values for some elements in that Table and it was decided to reintroduce the mass number for the radioactive elements into the main Table. In their 1983 Report, the Commission decided that radioactive elements were considered to lack a characteristic terrestrial isotopic composition, from which an atomic weight value could be calculated to five or more figure accuracy, without prior knowledge of the sample involved. These elements were again listed in the Atomic Weights Table with no further information, i.e., with no mass number or atomic weight value. For the elements, which have no stable characteristic terrestrial isotopic composition, the data on the half-lives and the relative atomic masses for the nuclides of interest for those elements have been evaluated. The values of the half-lives with their uncertainties are listed in the table. The uncertainties are given for the last digit quoted of the half-life and are given in parentheses. A half-life entry for the Table having a value and an uncertainty of 7 {+-} 3 is listed in the half-life column as 7 (3). The criteria to include data in this Table, is to be the same as it has been for over sixty years. It is the same criteria, which are used for all data that are evaluated for inclusion in the Standard Table of Atomic Weights. If a report of data is published in a peer-reviewed journal, that data is evaluated and considered for inclusion in the appropriate table of the biennial report of the Atomic Weights Commission. As better data becomes available in the future, the information that is contained in either of the Tables of Standard Atomic Weights or in the Table of Radioactive Elements may be modified. It should be noted that the appearance of any datum in the Table of the Radioactive Elements is merely for the purposes of calculating an atomic mass value for any sample of a radioactive material, which might have a variety of isotopic compositions and it has no implication as to the priority for claiming discovery of a given element and is not intended to. The atomic mass values have been taken primarily from the 2003 Atomic Mass Table. Mass values for those radioisotopes that do not appear in the 2003 Atomic mass Table have been taken from preliminary data of the Atomic Mass Data Center. Most of the quoted half-lives.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Carbon, Nitrogen, and Sulfur Analysis of the Cetama Viognier Standard Reference Material

The Viognier sample was analyzed for C, N, and S concentrations and stable isotope compositions using an Elementar Vario Isotope Cube Elemental Analyzer (EA) that is coupled to an IsoPrime PrecisION IRMS. Powder samples were placed in tin capsules and then loaded onto a rotary autosampler. The autosampler dropped samples into the EA, and samples were combusted at 1175 °C over tungsten oxide in a continuous stream of helium carrier gas. A pulse of oxygen is added to the gas stream resulting in flash combustion of the tin capsule containing the sample, which raises the reaction temperature to approximately 1800 °C for a few seconds. The combustion reaction produces SO 2 , N 2 and CO 2 from any sulfur, nitrogen and carbon present in the sample. The resulting gases were then passed through a reduced copper reactor that was heated to 850 °C, to reduce NO x to N 2 , reduce SO 3 to SO 2 , and trap any volatile halogen compounds on silver wool. Following water removal using an adsorption tube, the N 2 , CO 2 , and SO 2 analyte gases were separated and purified using purge-trap columns. The purified gases were then carried through a thermal conductivity detector. The detector signal was passed to software that calculated elemental abundances based on integrated peak areas. The sample gases were then passed to the IRMS and stable isotope ratios were measured. Raw sample peak areas were corrected by subtracting the average peak area from blanks consisting of empty tin capsules run using the same EA analysis method. Blanks were also run following each replicate to verify that all the material was combusted. The Viognier sample was analyzed in triplicate on two days (target sample masses: 30, 60 and 90 mg). The following standards were analyzed to calibrate EA-IRMS measurements: IAEA-C6, USGS-40, USGS-41, IAEA-S1, and IAEA-S2.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Determining Equilibrium Position For Acoustical Levitation

Equilibrium position and orientation of acoustically-levitated weightless object determined by calibration technique on Earth. From calibration data, possible to calculate equilibrium position and orientation in presence of Earth gravitation. Sample not levitated acoustically during calibration. Technique relies on Boltzmann-Ehrenfest adiabatic-invariance principle. One converts resonant-frequency-shift data into data on normalized acoustical potential energy. Minimum of energy occurs at equilibrium point. From gradients of acoustical potential energy, one calculates acoustical restoring force or torque on objects as function of deviation from equilibrium position or orientation.

Barmatz, M. B.↗

Towards application of a neutron cross-section uncertainty propagation capability in the criticality safety methodology - 14434

At the Paul Scherrer Institute (PSI) the methodology for criticality safety evaluations (CSE) used for Swiss applications is focused, following common practice, on establishing an upper subcriticality limit (USL) for the effective neutron multiplication factor (k{sub eff}), based on a statistical evaluation of the obtained validation results in terms of the calculated-to-benchmark k{sub eff} values. Recently, a new computational tool referred to as NUSS (Nuclear data Uncertainty Stochastic Sampling) was developed in order to propagate neutron-nuclear data (ND) uncertainties in calculations with Monte Carlo transport codes in combination with general-purpose ND libraries in ACE format. Thereby, this tool should now allow for a quantification of ND data uncertainties in CSE and to introduce these into the CSE criteria definition. This paper concerns an application of the NUSS methodology for criticality validation studies. Calculated k{sub eff} uncertainty estimations were obtained for the current PSI validation suite including in total 149 critical benchmark configurations for which in-house MCNP(X) models were developed, covering both uranium and mixed uranium-plutonium oxide fuels. The MCNPX-2.7.0 code was used together with the ENDF/B-VII.1 ND library while the ND variance-covariance matrixes (VCM) were taken from both SCALE-6.0 44-group libraries and also from ENDF/B-VII.1 files. Based on the newly obtained information on the uncertainties, a re-assessment of the lower tolerance bound (LTB) for k{sub eff} using the total uncertainties as weighting factors is proposed as means for the present PSI CSE methodology upgrade and some possible directions of further methodology enhancements are discussed next. (authors)

42 ENGINEERING↗

Detailed investigation of defect states in Erbium doped In2O3 thin films

Highlights: • SIMS analysis confirmed the doping of Er into the In{sub 2}O{sub 3} TF. • I–V loop analysis gives reduced current memory window for In{sub 2}O{sub 3}:Er TF based device. • High ideality factor was determined at low temperature and explained. • Defect related photoconductivity was confirmed from low temperature measurement. • 10 K temporal response of the Au/In{sub 2}O{sub 3}:Er/Si confirmed removal of oxygen defects. - Abstract: Erbium doped Indium Oxide (In{sub 2}O{sub 3}:Er) thin films (TFs) were synthesised by spin-on technique. Secondary Ion Mass Spectrometry confirmed that Er is incorporated into the In{sub 2}O{sub 3} lattice and formed an In-O-Er layer. The current–voltage loop produced a lower loop current window of ∼3.6 × 10{sup −4} A for In{sub 2}O{sub 3}:Er TF based devices. The Au/In{sub 2}O{sub 3}:Er/Si Schottky devices have lower ideality factor (∼6) and higher barrier height (∼0.63 eV) at 300 K than Au/In{sub 2}O{sub 3}/Si control samples. A blue shift in the main band-gap (∼50 nm) was calculated for In{sub 2}O{sub 3}:Er TFs from 10 K photoresponse. The Au/In{sub 2}O{sub 3}:Er/Si samples show higher photosensitivity in the temperature range 10 K–300 K and maximum (∼15 times) in the UV region at 10 K as compared to the Au/In{sub 2}O{sub 3}/Si devices. In addition, the Au/In{sub 2}O{sub 3}:Er/Si devices have better UV to visible cut-off ratio (∼3 times). Excellent temporal responses were recorded for Au/In{sub 2}O{sub 3}:Er/Si in the UV region as compared to Au/In{sub 2}O{sub 3}/Si.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

WIYN Open Cluster Study. LXVI. Spectroscopic binary orbits in the young open cluster M35 (NGC 2168)

The young (150 Myr) open cluster M35 (NGC 2168) has been one of the core clusters of the WIYN Open Cluster Study since 1997. Over these 17 years we have obtained approximately 8000 radial-velocity (RV) measurements of stars in the M35 field, which we provide here. Our target sample consists of 1355 photometrically selected stars in the field of M35 within the main sequence and binary sequence of the cluster and within 13⩽V⩽16.5 and (B−V)⩾0.6. Using our RV measurements we cleanly separate likely cluster members from field stars. We calculate RV membership probabilities for over 1200 stars in our sample. 418 are probable cluster members, of which 64 are velocity-variable (binary) systems. Here we present 52 orbital solutions for binary members of M35. This sample defines the hard binary population of M35 that dynamically powers the cluster. We also present XMM-Newton X-ray detections within the cluster. We use our large binary sample to search for interacting binaries among the X-ray sources, investigate M35's period–eccentricity distribution, and determine binary frequency. We find a circularization period of 9.9 ± 1.2 days and a binary frequency of 24% ± 3% for main-sequence binaries with P<10{sup 4} days. Determining these properties in a young cluster like M35 is key to defining the initial conditions used in models of cluster dynamical evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

A fast Monte Carlo cell-by-cell simulation for radiobiological effects in targeted radionuclide therapy using pre-calculated single-particle track standard DNA damage data

Introduction: We developed a new method that drastically speeds up radiobiological Monte Carlo radiation-track-structure (MC-RTS) calculations on a cell-by-cell basis. Methods: The technique is based on random sampling and superposition of single-particle track (SPT) standard DNA damage (SDD) files from a “pre-calculated” data library, constructed using the RTS code TOPAS-nBio, with “time stamps” manually added to incorporate dose-rate effects. This time-stamped SDD file can then be input into MEDRAS, a mechanistic kinetic model that calculates various radiation-induced biological endpoints, such as DNA double-strand breaks (DSBs), misrepairs and chromosomal aberrations, and cell death. As a benchmark validation of the approach, we calculated the predicted energy-dependent DSB yield and the ratio of direct-to-total DNA damage, both of which agreed with published in vitro experimental data. We subsequently applied the method to perform a superfast cell-by-cell simulation of an experimental in vitro system consisting of neuroendocrine tumor cells uniformly incubated with 177 Lu. Results and discussion: The results for residual DSBs, both at 24 and 48 h post-irradiation, are in line with the published literature values. Our work serves as a proof-of-concept demonstration of the feasibility of a cost-effective “in silico clonogenic cell survival assay” for the computational design and development of radiopharmaceuticals and novel radiotherapy treatments more generally.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Procedures for estimating the frequency of commercial airline flights encountering high cabin ozone levels

Three analytical problems in estimating the frequency at which commercial airline flights will encounter high cabin ozone levels are formulated and solved: namely, estimating flight-segment mean levels, estimating maximum-per-flight levels, and estimating the maximum average level over a specified flight interval. For each problem, solution procedures are given for different levels of input information - from complete cabin ozone data, which provides a direct solution, to limited ozone information, such as ambient ozone means and standard deviations, with which several assumptions are necessary to obtain the required estimates. Each procedure is illustrated by an example case calculation that uses simultaneous cabin and ambient ozone data obtained by the NASA Global Atmospheric Sampling Program. Critical assumptions are discussed and evaluated, and the several solutions for each problem are compared. Example calculations are also performed to illustrate how variations in lattitude, altitude, season, retention ratio, flight duration, and cabin ozone limits affect the estimated probabilities.

Holdeman, J. D.↗

Band structure dependent electronic localization in macroscopic films of single-chirality single-wall carbon nanotubes

Significant understanding has been achieved over the last few decades regarding chirality-dependent properties of single-wall carbon nanotubes (SWCNTs), primarily through single-tube studies. However, macroscopic manifestations of chirality dependence have been limited, especially in electronic transport, despite the fact that such distinct behaviors are needed for many applications of SWCNT-based devices. In addition, developing reliable transport theory is challenging since a description of localization phenomena in an assembly of nanoobjects requires precise knowledge of disorder on multiple spatial scales, particularly if the ensemble is heterogeneous. Here, we report an observation of pronounced chirality-dependent electronic localization in temperature and magnetic field dependent conductivity measurements on macroscopic films of single-chirality SWCNTs. The samples included large-gap semiconducting (6,5) and (10,3) films, narrow-gap semiconducting (7,4) and (8,5) films, and armchair metallic (6,6) films. Experimental data and theoretical calculations revealed Mott variable-range-hopping dominated transport in all samples, while localization lengths fall into three distinct categories depending on their band gaps. Armchair films have the largest localization length. Here our detailed analyses on electronic transport properties of single-chirality SWCNT films provide significant new insight into electronic transport in ensembles of nanoobjects, offering foundations for designing and deploying macroscopic SWCNT solid-state devices.

36 MATERIALS SCIENCE↗

Evaluation of Naturally Occurring Be-7 Activity on LANL Stack Filter Clumps

Los Alamos National Laboratory (LANL) is responsible for providing solutions to challenging issues through multidisciplinary science, engineering, and technology that impact national security. As part of the Radioactive Air Emissions Management (RAEM) Team, it is our responsibility to ensure LANL operates within the requirements of the Code of Federal Regulations 40 CFR 61, Subpart H, National Emission Standards for Emissions of Radionuclides Other Than Radon From Department of Energy Facilities (Rad-NESHAP). The standard states, “Emissions of radionuclides to the ambient air from Department of Energy facilities shall not exceed those amounts that would cause any member of the public to receive in any year an effective dose equivalent of 10 mrem/yr” (EPA, 2002) During a routine assessment of LANL’s Rad-NESHAP compliance program, an opportunity for improvement was identified that addresses the evaluation of routine stack samples which potentially have naturally occurring radioactive materials (NORM) on the filter media. In the past and based on professional judgment, detections of NORM such as K-40 and Be-7 typically were rejected from the analytical results. The assessment finding suggested developing a technical criterion to ensure that such rejections were justified, comparing actual measured values with anticipated NORM concentrations for various stacks located at LANL. The significance of accepting or rejecting samples as “true” or “NORM” and its impact on the RAEM’s mission and compliance to the regulations is explained later in the document. Additionally, this document will describe the process and calculations for how such results are to be accepted as actual samples “true positive” or rejected as NORM.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Whitepaper on Uncertainty Quantification for MPACT

The MPACT code provides the ability to perform high-fidelity deterministic calculations to obtain a wide variety of detailed results for very complex reactor core models. However, MPACT currently does not have the capability to propagate the effects of input data uncertainties to provide uncertainties in the calculated results. This white paper discusses a potential method for MPACT uncertainty quantification (UQ) based on stochastic sampling.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Remarkable low-energy properties of the pseudogapped semimetal Be 5 Pt

We report measurements and calculations on the properties of the intermetallic compound Be 5 Pt. High-quality polycrystalline samples show a nearly constant temperature dependence of the electrical resistivity over a wide temperature range. On the other hand, relativistic electronic structure calculations indicate the existence of a narrow pseudogap in the density of states arising from accidental approximate Dirac cones extremely close to the Fermi level. A small true gap of order ~ 3 meV is present at the Fermi level, yet the measured resistivity is nearly constant from low to room temperature. We argue that this unexpected behavior can be understood by a cancellation of the energy dependence of density of states and relaxation time due to disorder, and discuss a model for electronic transport. With applied pressure, the resistivity becomes semiconducting, consistent with theoretical calculations that show that the band gap increases with applied pressure. We further discuss the role of Be inclusions in the samples.

36 MATERIALS SCIENCE↗

Liquid Metering Centrifuge Sticks (LMCS): A Centrifugal Approach to Metering Known Sample Volumes for Colorimetric Solid Phase Extraction (C-SPE)

Phase separation is one of the most significant obstacles encountered during the development of analytical methods for water quality monitoring in spacecraft environments. Removing air bubbles from water samples prior to analysis is a routine task on earth; however, in the absence of gravity, this routine task becomes extremely difficult. This paper details the development and initial ground testing of liquid metering centrifuge sticks (LMCS), devices designed to collect and meter a known volume of bubble-free water in microgravity. The LMCS uses centrifugal force to eliminate entrapped air and reproducibly meter liquid sample volumes for analysis with Colorimetric Solid Phase Extraction (C-SPE). C-SPE is a sorption-spectrophotometric platform that is being developed as a potential spacecraft water quality monitoring system. C-SPE utilizes solid phase extraction membranes impregnated with analyte-specific colorimetric reagents to concentrate and complex target analytes in spacecraft water samples. The mass of analyte extracted from the water sample is determined using diffuse reflectance (DR) data collected from the membrane surface and an analyte-specific calibration curve. The analyte concentration can then be calculated from the mass of extracted analyte and the volume of the sample analyzed. Previous flight experiments conducted in microgravity conditions aboard the NASA KC-135 aircraft demonstrated that the inability to collect and meter a known volume of water using a syringe was a limiting factor in the accuracy of C-SPE measurements. Herein, results obtained from ground based C-SPE experiments using ionic silver as a test analyte and either the LMCS or syringes for sample metering are compared to evaluate the performance of the LMCS. These results indicate very good agreement between the two sample metering methods and clearly illustrate the potential of utilizing centrifugal forces to achieve phase separation and metering of water samples in microgravity.

Gazda, Daniel B.↗

Emission-Line Metallicities from the Faint Infrared Grism Survey and VLT/MUSE

We derive direct-measurement gas-phase metallicities of 7.4 < 12 + log(O/H) < 8.4 for 14 low-mass emission- line galaxies at 0.3 < z < 0.8 identified in the Faint Infrared Grism Survey. We use deep slitless G102 grism spectroscopy of the Hubble Ultra Deep Field, dispersing light from all objects in the field at wavelengths between 0.85 and 1.15 μm. We run an automatic search routine on these spectra to robustly identify 71 emission-line sources, using archival data from Very Large Telescope (VLT)/Multi-Unit Spectroscopic Explorer (MUSE) to measure additional lines and confirm redshifts. We identify 14 objects with 0.3 < z < 0.8 with measurable [O III] λ4363 Å emission lines in matching VLT/MUSE spectra. For these galaxies, we derive direct electron-temperature gas-phase metallicities with a range of 7.4 < 12 + log(O/H) < 8.4. With matching stellar masses in the range of 10(exp 7.9) Solar Mass < M(sub *) < 10(exp 10.4) Solar Mass, we construct a mass–metallicity (MZ) relation and find that the relation is offset to lower metallicities compared to metallicities derived from alternative methods (e.g., R(sub 23), O3N2, N2O2) and continuum selected samples. Using star formation rates derived from the Hα emission line, we calculate our galaxies’ position on the Fundamental Metallicity Relation, where we also find an offset toward lower metallicities. This demonstrates that this emission-line-selected sample probes objects of low stellar masses but even lower metallicities than many comparable surveys. We detect a trend suggesting galaxies with higher Specific Star Formation (SSFR) are more likely to have lower metallicity. This could be due to cold accretion of metal-poor gas that drives star formation, or could be because outflows of metal-rich stellar winds and SNe ejecta are more common in galaxies with higher SSFR.

Pharo, John↗