Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SIMULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Validation of Varian TrueBeam electron phase–spaces for Monte Carlo simulation of MLC-shaped fields

Purpose: This work evaluates Varian’s electron phase–space sources for Monte Carlo simulation of the TrueBeam for modulated electron radiation therapy (MERT) and combined, modulated photon and electron radiation therapy (MPERT) where fields are shaped by the photon multileaf collimator (MLC) and delivered at 70 cm SSD. Methods: Monte Carlo simulations performed with EGSnrc-based BEAMnrc/DOSXYZnrc and PENELOPE-based PRIMO are compared against diode measurements for 5 × 5, 10 × 10, and 20 × 20 cm{sup 2} MLC-shaped fields delivered with 6, 12, and 20 MeV electrons at 70 cm SSD (jaws set to 40 × 40 cm{sup 2}). Depth dose curves and profiles are examined. In addition, EGSnrc-based simulations of relative output as a function of MLC-field size and jaw-position are compared against ion chamber measurements for MLC-shaped fields between 3 × 3 and 25 × 25 cm{sup 2} and jaw positions that range from the MLC-field size to 40 × 40 cm{sup 2}. Results: Percent depth dose curves generated by BEAMnrc/DOSXYZnrc and PRIMO agree with measurement within 2%, 2 mm except for PRIMO’s 12 MeV, 20 × 20 cm{sup 2} field where 90% of dose points agree within 2%, 2 mm. Without the distance to agreement, differences between measurement and simulation are as large as 7.3%. Characterization of simulated dose parameters such as FWHM, penumbra width and depths of 90%, 80%, 50%, and 20% dose agree within 2 mm of measurement for all fields except for the FWHM of the 6 MeV, 20 × 20 cm{sup 2} field which falls within 2 mm distance to agreement. Differences between simulation and measurement exist in the profile shoulders and penumbra tails, in particular for 10 × 10 and 20 × 20 cm{sup 2} fields of 20 MeV electrons, where both sets of simulated data fall short of measurement by as much as 3.5%. BEAMnrc/DOSXYZnrc simulated outputs agree with measurement within 2.3% except for 6 MeV MLC-shaped fields. Discrepancies here are as great as 5.5%. Conclusions: TrueBeam electron phase–spaces available from Varian have been implemented in two distinct Monte Carlo simulation packages to produce dose distributions and outputs that largely reflect measurement. Differences exist in the profile shoulders and penumbra tails for the 20 MeV phase–space off-axis and in the outputs for the 6 MeV phase–space.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-T-50: Evaluation of Monte Carlo Simulations Performance for Pediatric Brachytherapy Dosimetry

Purpose: Pediatric tumors are generally treated with multi-modal procedures. Brachytherapy can be used with pediatric tumors, especially given that in this patient population low toxicity on normal tissues is critical as is the suppression of the probability for late malignancies. Our goal is to validate the GATE toolkit on realistic brachytherapy applications, and evaluate brachytherapy plans on pediatrics for accurate dosimetry on sensitive and critical organs of interest. Methods: The GATE Monte Carlo (MC) toolkit was used. Two High Dose Rate (HDR) 192Ir brachytherapy sources were simulated (Nucletron mHDR-v1 and Varian VS2000), and fully validated using the AAPM and ESTRO protocols. A realistic brachytherapy plan was also simulated using the XCAT anthropomorphic computational model .The simulated data were compared to the clinical dose points. Finally, a 14 years old girl with vaginal rhabdomyosarcoma was modelled based on clinical procedures for the calculation of the absorbed dose per organ. Results: The MC simulations resulted in accurate dosimetry in terms of dose rate constant (Λ), radial dose gL(r) and anisotropy function F(r,θ) for both sources.The simulations were executed using ∼1010 number of primaries resulting in statistical uncertainties lower than 2%.The differences between the theoretical values and the simulated ones ranged from 0.01% up to 3.3%, with the largest discrepancy (6%) being observed in the dose rate constant calculation.The simulated DVH using an adult female XCAT model was also compared to a clinical one resulting in differences smaller than 5%. Finally, a realistic pediatric brachytherapy simulation was performed to evaluate the absorbed dose per organ and to calculate DVH with respect to heterogeneities of the human anatomy. Conclusion: GATE is a reliable tool for brachytherapy simulations both for source modeling and for dosimetry in anthropomorphic voxelized models. Our project aims to evaluate a variety of pediatric brachytherapy schemes using a population of pediatric phantoms for several pathological cases. This study is part of a project that has received funding from the European Union Horizon2020 research and innovation programme under the MarieSklodowska-Curiegrantagreement.No691203.The results published in this study reflect only the authors view and the Research Executive Agency (REA) and the European Commission is not responsible for any use that may be madeof the information it contains.

60 APPLIED LIFE SCIENCES↗

SU-F-T-146: Comparing Monte Carlo Simulations with Commissioning Beam Data for Mevion S250 Proton Therapy System

Purpose: To evaluate the Monte Carlo simulated beam data with the measured commissioning data for the Mevion S250 proton therapy system. Method: The Mevion S250 proton therapy system utilizes a passive double scattering technique with a unique gantry mounted superconducting accelerator and offers effective proton therapy in a compact design concept. The field shaping system (FSS) includes first scattering foil, range modulator wheel (RMW), second scattering foil and post absorber and offers two field sizes and a total of 24 treatment options from proton range of 5 cm to 32 cm. The treatment nozzle was modeled in detail using TOPAS (TOolkit for PArticle Simulation) Monte Carlo code. The timing feathers of the moving modulator wheels were also implemented to generate the Spread Out Bragg Peak (SOBP). The simulation results including pristine Bragg Peak, SOBP and dose profiles were compared with the data measured during beam commissioning. Results: The comparison between the measured data and the simulation data show excellent agreement. For pristine proton Bragg Peaks, the simulated proton range (depth of distal 90%) values agreed well with the measured range values within 1 mm accuracy. The differences of the distal falloffs (depth from distal 80% to 20%) were also found to be less than 1 mm between the simulations and measurements. For the SOBP, the widths of modulation (depth of proximal 95% to distal 90%) were also found to agree with the measurement within 1 mm. The flatness of the simulated and measured lateral profiles was found to be 0.6 % and 1.1 %, respectively. Conclusion: The agreement between simulations and measurements demonstrate that TOPAS could be used as a viable platform to proton therapy applications. The matched simulation results offer a great tool and open opportunity for variety of applications.

60 APPLIED LIFE SCIENCES↗

SU-F-T-156: Monte Carlo Simulation Using TOPAS for Synchrotron Based Proton Discrete Spot Scanning System

Purpose: This study provides an overview of the design and commissioning of the Monte Carlo (MC) model of the spot-scanning proton therapy nozzle and its implementation for the patient plan simulation. Methods: The Hitachi PROBEAT V scanning nozzle was simulated based on vendor specifications using the TOPAS extension of Geant4 code. FLUKA MC simulation was also utilized to provide supporting data for the main simulation. Validation of the MC model was performed using vendor provided data and measurements collected during acceptance/commissioning of the proton therapy machine. Actual patient plans using CT based treatment geometry were simulated and compared to the dose distributions produced by the treatment planning system (Varian Eclipse 13.6), and patient quality assurance measurements. In-house MATLAB scripts are used for converting DICOM data into TOPAS input files. Results: Comparison analysis of integrated depth doses (IDDs), therapeutic ranges (R90), and spot shape/sizes at different distances from the isocenter, indicate good agreement between MC and measurements. R90 agreement is within 0.15 mm across all energy tunes. IDDs and spot shapes/sizes differences are within statistical error of simulation (less than 1.5%). The MC simulated data, validated with physical measurements, were used for the commissioning of the treatment planning system. Patient geometry simulations were conducted based on the Eclipse produced DICOM plans. Conclusion: The treatment nozzle and standard option beam model were implemented in the TOPAS framework to simulate a highly conformal discrete spot-scanning proton beam system.

60 APPLIED LIFE SCIENCES↗

SU-F-T-471: Simulated External Beam Delivery Errors Detection with a Large Area Ion Chamber Transmission Detector

Purpose: The Integral Quality Monitor (IQM), developed by iRT Systems GmbH (Koblenz, Germany) is a large-area, linac-mounted ion chamber used to monitor photon fluence during patient treatment. Our previous work evaluated the change of the ion chamber’s response to deviations from static 1×1 cm2 and 10×10 cm2 photon beams and other characteristics integral to use in external beam detection. The aim of this work is to simulate two external beam radiation delivery errors, quantify the detection of simulated errors and evaluate the reduction in patient harm resulting from detection. Methods: Two well documented radiation oncology delivery errors were selected for simulation. The first error was recreated by modifying a wedged whole breast treatment, removing the physical wedge and calculating the planned dose with Pinnacle TPS (Philips Radiation Oncology Systems, Fitchburg, WI). The second error was recreated by modifying a static-gantry IMRT pharyngeal tonsil plan to be delivered in 3 unmodulated fractions. A radiation oncologist evaluated the dose for simulated errors and predicted morbidity and mortality commiserate with the original reported toxicity, indicating that reported errors were approximately simulated. The ion chamber signal of unmodified treatments was compared to the simulated error signal and evaluated in Pinnacle TPS again with radiation oncologist prediction of simulated patient harm. Results: Previous work established that transmission detector system measurements are stable within 0.5% standard deviation (SD). Errors causing signal change greater than 20 SD (10%) were considered detected. The whole breast and pharyngeal tonsil IMRT simulated error increased signal by 215% and 969%, respectively, indicating error detection after the first fraction and IMRT segment, respectively. Conclusion: The transmission detector system demonstrated utility in detecting clinically significant errors and reducing patient toxicity/harm in simulated external beam delivery. Future work will evaluate detection of other smaller magnitude delivery errors.

60 APPLIED LIFE SCIENCES↗

SU-G-BRC-10: Feasibility of a Web-Based Monte Carlo Simulation Tool for Dynamic Electron Arc Radiotherapy (DEAR)

Purpose: DEAR is a radiation therapy technique utilizing synchronized motion of gantry and couch during delivery to optimize dose distribution homogeneity and penumbra for treatment of superficial disease. Dose calculation for DEAR is not yet supported by commercial TPSs. The purpose of this study is to demonstrate the feasibility of using a web-based Monte Carlo (MC) simulation tool (VirtuaLinac) to calculate dose distributions for a DEAR delivery. Methods: MC simulations were run through VirtuaLinac, which is based on the GEANT4 platform. VirtuaLinac utilizes detailed linac head geometry and material models, validated phase space files, and a voxelized phantom. The input was expanded to include an XML file for simulation of varying mechanical axes as a function of MU. A DEAR XML plan was generated and used in the MC simulation and delivered on a TrueBeam in Developer Mode. Radiographic film wrapped on a cylindrical phantom (12.5 cm radius) measured dose at a depth of 1.5 cm and compared to the simulation results. Results: A DEAR plan was simulated using an energy of 6 MeV and a 3×10 cm{sup 2} cut-out in a 15×15 cm{sup 2} applicator for a delivery of a 90° arc. The resulting data were found to provide qualitative and quantitative evidence that the simulation platform could be used as the basis for DEAR dose calculations. The resulting unwrapped 2D dose distributions agreed well in the cross-plane direction along the arc, with field sizes of 18.4 and 18.2 cm and penumbrae of 1.9 and 2.0 cm for measurements and simulations, respectively. Conclusion: Preliminary feasibility of a DEAR delivery using a web-based MC simulation platform has been demonstrated. This tool will benefit treatment planning for DEAR as a benchmark for developing other model based algorithms, allowing efficient optimization of trajectories, and quality assurance of plans without the need for extensive measurements.

60 APPLIED LIFE SCIENCES↗

MO-FG-BRA-01: 4D Monte Carlo Simulations for Verification of Dose Delivered to a Moving Anatomy

Purpose: To validate 4D Monte Carlo (MC) simulations of dose delivery by an Elekta Agility linear accelerator to a moving phantom. Methods: Monte Carlo simulations were performed using the 4DdefDOSXYZnrc/EGSnrc user code which samples a new geometry for each incident particle and calculates the dose in a continuously moving anatomy. A Quasar respiratory motion phantom with a lung insert containing a 3 cm diameter tumor was used for dose measurements on an Elekta Agility linac with the phantom in stationary and moving states. Dose to the center of tumor was measured using calibrated EBT3 film and the RADPOS 4D dosimetry system. A VMAT plan covering the tumor was created on the static CT scan of the phantom using Monaco V.5.10.02. A validated BEAMnrc model of our Elekta Agility linac was used for Monte Carlo simulations on stationary and moving anatomies. To compare the planned and delivered doses, linac log files recorded during measurements were used for the simulations. For 4D simulations, deformation vectors that modeled the rigid translation of the lung insert were generated as input to the 4DdefDOSXYZnrc code as well as the phantom motion trace recorded with RADPOS during the measurements. Results: Monte Carlo simulations and film measurements were found to agree within 2mm/2% for 97.7% of points in the film in the static phantom and 95.5% in the moving phantom. Dose values based on film and RADPOS measurements are within 2% of each other and within 2σ of experimental uncertainties with respect to simulations. Conclusion: Our 4D Monte Carlo simulation using the defDOSXYZnrc code accurately calculates dose delivered to a moving anatomy. Future work will focus on more investigation of VMAT delivery on a moving phantom to improve the agreement between simulation and measurements, as well as establishing the accuracy of our method in a deforming anatomy. This work was supported by the Ontario Consortium of Adaptive Interventions in Radiation Oncology (OCAIRO), funded by the Ontario Research Fund Research Excellence program.

60 APPLIED LIFE SCIENCES↗

Comparison of Lagrangian Superdroplet and Eulerian Double-Moment Spectral Microphysics Schemes in Large-Eddy Simulations of an Isolated Cumulus Congestus Cloud

Abstract Advanced microphysics schemes (such as Eulerian bin and Lagrangian superdroplet) are becoming standard tools for cloud physics research and parameterization development. This study compares a double-moment bin scheme and a Lagrangian superdroplet scheme via large-eddy simulations of nonprecipitating and precipitating cumulus congestus clouds. Cloud water mixing ratio in the bin simulations is reduced compared to the Lagrangian simulations in the upper part of the cloud, likely from numerical diffusion, which is absent in the Lagrangian approach. Greater diffusion in the bin simulations is compensated by more secondary droplet activation (activation above cloud base), leading to similar or somewhat higher droplet number concentrations and smaller mean droplet radius than the Lagrangian simulations for the nonprecipitating case. The bin scheme also produces a significantly larger standard deviation of droplet radius than the superdroplet method, likely due to diffusion associated with the vertical advection of bin variables. However, the spectral width in the bin simulations is insensitive to the grid spacing between 50 and 100 m, suggesting other mechanisms may be compensating for diffusion as the grid spacing is modified. For the precipitating case, larger spectral width in the bin simulations initiates rain earlier and enhances rain development in a positive feedback loop. However, with time, rain formation in the superdroplet simulations catches up to the bin simulations. Offline calculations using the same drop size distributions in both schemes show that the different numerical methods for treating collision–coalescence also contribute to differences in rain formation. The stochastic collision–coalescence in the superdroplet method introduces more variability in drop growth for a given rain mixing ratio.

54 ENVIRONMENTAL SCIENCES↗

ATS (Advanced Terrestrial Simulator) integrated hydrology and reactive transport model output in Copper Creek, Colorado

This dataset is generated using the ATS (Advanced Terrestrial Simulator) model at Copper Creek, Colorado, the largest catchment in the East River watershed. ATS is an integrated hydrology and reactive transport model to simulate the Concentration-Discharge (C-Q) relationship, and is used to quantify the geochemical export and understand how watersheds respond to climate disturbances. Key hydrogeochemical variables, including discharge, precipitation, evapotranspiration, and geochemical concentrations, were simulated and output at a daily frequency at the Copper Creek outlet. A group of hydrology and geochemical model variables over the spatial domain are output at a bi-monthly frequency. The model used 1-km resolution daily frequency Daymet meteorological forcing, and mineral composition from previous studies. The simulations are performed on NERSC. The datasets include the input files for running the ATS (Advanced Terrestrial Simulator) simulation, including the mesh file, input script and geochemical model files. The output files from the ATS (Advanced Terrestrial Simulator) are the daily time-series discharge and geochemical concentration simulated at the outlet of Copper Creek, and the bi-monthly spatial output over the simulation domain.

54 ENVIRONMENTAL SCIENCES↗

RELAP-7 Level 2 Milestone Report: Demonstration of a Steady State Single Phase PWR Simulation with RELAP-7

The document contains the simulation results of a steady state model PWR problem with the RELAP-7 code. The RELAP-7 code is the next generation nuclear reactor system safety analysis code being developed at Idaho National Laboratory (INL). The code is based on INL's modern scientific software development framework - MOOSE (Multi-Physics Object-Oriented Simulation Environment). This report summarizes the initial results of simulating a model steady-state single phase PWR problem using the current version of the RELAP-7 code. The major purpose of this demonstration simulation is to show that RELAP-7 code can be rapidly developed to simulate single-phase reactor problems. RELAP-7 is a new project started on October 1 st , 2011. It will become the main reactor systems simulation toolkit for RISMC (Risk Informed Safety Margin Characterization) and the next generation tool in the RELAP reactor safety/systems analysis application series (the replacement for RELAP5). The key to the success of RELAP-7 is the simultaneous advancement of physical models, numerical methods, and software design while maintaining a solid user perspective. Physical models include both PDEs (Partial Differential Equations) and ODEs (Ordinary Differential Equations) and experimental based closure models. RELAP-7 will eventually utilize well posed governing equations for multiphase flow, which can be strictly verified. Closure models used in RELAP5 and newly developed models will be reviewed and selected to reflect the progress made during the past three decades. RELAP-7 uses modern numerical methods, which allow implicit time integration, higher order schemes in both time and space, and strongly coupled multi-physics simulations. RELAP-7 is written with object oriented programming language C++. Its development follows modern software design paradigms. The code is easy to read, develop, maintain, and couple with other codes. Most importantly, the modern software design allows the RELAP-7 code to evolve with time. RELAP-7 is a MOOSE-based application. MOOSE (Multiphysics Object-Oriented Simulation Environment) is a framework for solving computational engineering problems in a well-planned, managed, and coordinated way. By leveraging millions of lines of open source software packages, such as PETSC (a nonlinear solver developed at Argonne National Laboratory) and LibMesh (a Finite Element Analysis package developed at University of Texas), MOOSE significantly reduces the expense and time required to develop new applications. Numerical integration methods and mesh management for parallel computation are provided by MOOSE. Therefore RELAP-7 code developers only need to focus on physics and user experiences. By using the MOOSE development environment, RELAP-7 code is developed by following the same modern software design paradigms used for other MOOSE development efforts. There are currently over 20 different MOOSE based applications ranging from 3-D transient neutron transport, detailed 3-D transient fuel performance analysis, to long-term material aging. Multi-physics and multiple dimensional analyses capabilities can be obtained by coupling RELAP-7 and other MOOSE based applications and by leveraging with capabilities developed by other DOE programs. This allows restricting the focus of RELAP-7 to systems analysis-type simulations and gives priority to retain and significantly extend RELAP5's capabilities.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

TGLF Recalibration for ITER Standard Case Parameters FY2015: Theory and Simulation Performance Target Final Report

This work was motivated by the observation, as early as 2008, that GYRO simulations of some ITER operating scenarios exhibited nonlinear zonal-flow generation large enough to effectively quench turbulence inside r /a ~ 0.5. This observation of flow-dominated, low-transport states persisted even as more accurate and comprehensive predictions of ITER profiles were made using the state-of-the-art TGLF transport model. This core stabilization is in stark contrast to GYRO-TGLF comparisons for modern-day tokamaks, for which GYRO and TGLF are typically in very close agreement. So, we began to suspect that TGLF needed to be generalized to include the effect of zonal-flow stabilization in order to be more accurate for the conditions of reactor simulations. While the precise cause of the GYRO-TGLF discrepancy for ITER parameters was not known, it was speculated that closeness to threshold in the absence of driven rotation, as well as electromagnetic stabilization, created conditions more sensitive the self-generated zonal-flow stabilization than in modern tokamaks. Need for nonlinear zonal-flow stabilization: To explore the inclusion of a zonal-flow stabilization mechanism in TGLF, we started with a nominal ITER profile predicted by TGLF, and then performed linear and nonlinear GYRO simulations to characterize the behavior at and slightly above the nominal temperature gradients for finite levels of energy transport. Then, we ran TGLF on these cases to see where the discrepancies were largest. The predicted ITER profiles were indeed near to the TGLF threshold over most of the plasma core in the hybrid discharge studied (weak magnetic shear, q > 1). Scanning temperature gradients above the TGLF power balance values also showed that TGLF overpredicted the electron energy transport in the low-collisionality ITER plasma. At first (in Q3), a model of only the zonal-flow stabilization (Dimits shift) was attempted. Although we were able to construct an ad hoc model of the zonal flows that fit the GYRO simulations, the parameters of the model had to be tuned to each case. A physics basis for the zonal flow model was lacking. Electron energy transport at short wavelength: A secondary issue – the high-k electron energy flux – was initially assumed to be independent of the zonal flow effect. However, detailed studies of the fluctuation spectra from recent multiscale (electron and ion scale) GYRO simulations provided a critical new insight into the role of zonal flows. The multiscale simulations suggested that advection by the zonal flows strongly suppressed electron-scale turbulence. Radial shear of the zonal E×B fluctuation could not compete with the large electron-scale linear growth rate, but the k x -mixing rate of the E×B advection could. This insight led to a preliminary new model for the way zonal flows saturate both electron- and ion-scale turbulence. It was also discovered that the strength of the zonal E×B velocity could be computed from the linear growth rate spectrum. The new saturation model (SAT1), which replaces the original model (SAT0), was fit to the multiscale GYRO simulations as well as the ion-scale GYRO simulations used to calibrate the original SAT0 model. Thus, SAT1 captures the physics of both multiscale electron transport and zonal-flow stabilization. In future work, the SAT1 model will require significant further testing and (expensive) calibration with nonlinear multiscale gyrokinetic simulations over a wider variety of plasma conditions – certainly more than the small set of scans about a single C-Mod L-mode discharge. We believe the SAT1 model holds great promise as a physics-based model of the multiscale turbulent transport in fusion devices. Correction to ITER performance predictions: Finally, the impact of the SAT1model on the ITER hybrid case is mixed. Without the electron-scale contribution to the fluxes, the Dimits shift makes a significant improvement in the predicted fusion power as originally posited. Alas, including the high-k electron transport reduces the improvement, yielding a modest net increase in predicted fusion power compared to the TGLF prediction with the original SAT0 model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Path Integral Monte Carlo Simulations of Iron Plasmas (Final Technical Report)

This documents is the final technical report for our grant entitled "Path Integral Monte Carlo Simulations of Iron Plasmas" that focused on developing path integral Monte Carlo (PIMC) computer simulations. This techniques will be developed to study plasmas composed of heavier elements including iron and other third row elements. Equations of state (EOS) and transport properties will be derived in the regime of warm dense matter (WDM) and dense plasmas where existing first-principles methods cannot be applied. While standard density functional theory (DFT) has been used to accurately predict the structure of many solids and liquids up to temperatures on the order of 100,000 K, this method is not applicable at much higher temperature because the number of partially occupied electronic orbitals reaches intractably large numbers or the use of finite-temperature free energy functionals in orbital-free DFT introduces an uncontrolled approximation. Here we focus on PIMC methods that become more and more efficient with increasing temperatures and still include all electronic correlation effects. In this approach, electronic excitations increase the efficiency rather than reduce it. While it had commonly been assumed this method could only be applied to elements without core electrons, we showed that PIMC with free-particle nodes works well for first-row elements (PRL 108 (2012) 115502). Most recently, we extended the applicability range of all-electron PIMC to second-row elements by adopting localized nodal surfaces (PRL 115 (2015) 176403). To simulate third-row elements efficiently under WDM conditions, we propose a new method to remove core electrons by introducing pseudo-nodes. We explain our approach step by step and present preliminary results. We focus our method development on getting PIMC simulations of iron to work because of its fundamental importance for WDM and astrophysics. Then we move on to krypton and copper-doped beryllium, a ICF ablator material. We plan to continue working on key second-row material such as Na, Mg, MgO, Al, silica, and silicon-doped plastic ablators. Our collaborators at LLNL, will use our PIMC EOS data both as comparisons to existing semi-empirical, EOS-generating schemes, and as input for continuum radiation hydrodynamics simulations. We will establish an efficient pipeline from PIMC to macroscopic continuum studies of materials response. An emphasis will be placed on benchmarking such methods for plasmas of heavy elements at the very high temperatures (~100 eV) and low densities that are generated when Hohlraum radiation heats the ablator material in indirect drive laser experiments. Results from changes to the EOS will be of immeasurable importance to the designers at the National Ignition Facility (NIF) and at other facilities. Starting with our EOS of Cu-doped Be, our second collaborator at LLE, will perform real-time simulations of laser fusion experiments at the Omega laser and at the NIF to determine how sensitive the compression path depends on the ablator EOS. Since our collaborator also has experience in performing orbital-free DFT calculations, we propose to compare predictions from this method with PIMC results. In joint publications, we plan to analyze the accuracy of different free-energy functionals in order to understand why existing orbital-free DFT calculations do not predict compression peaks along the shock Hugoniot curve that we see with PIMC. The peaks are caused by the ionization of various electron shells. Their accurate characterization is important to compare with experimental results. We will break new ground by developing PIMC techniques that can simulate iron and all other third row elements in the plasma and WDM regimes. We introduce the concept of pseudo-nodes for the efficient treatment of the core-electrons. The EOS and transport properties will be derived and published online in the form of a new WDM database. Our PIMC EOS calculations will benchmark and possibly replace semi-analytical EOS tables like QEOS or SESAME, which will impact the hydrocode simulation community and will affect the design of NIF targets. Our PIMC results will help to improve the accuracy of orbital-free DFT simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Vehicle Powertrain Simulation Accuracy for Various Drive Cycle Frequencies and Upsampling Techniques

As connected and automated vehicle technologies emerge and proliferate, lower frequency vehicle trajectory data is becoming more widely available. In some cases, entire fleets are streaming position, speed, and telemetry at sample rates of less than 10 seconds. This presents opportunities to apply powertrain simulators such as the National Renewable Energy Laboratory's Future Automotive Systems Technology Simulator to model how advanced powertrain technologies would perform in the real world. However, connected vehicle data tends to be available at lower temporal frequencies than the 1-10 Hz trajectories that have typically been used for powertrain simulation. Higher frequency data, typically used for simulation, is costly to collect and store and therefore is often limited in density and geography. This paper explores the suitability of lower frequency, high availability, connected vehicle data for detailed powertrain simulation. A large data set of 1 Hz trajectories is used to quantify the accuracy loss when simulating energy consumption for conventional, hybrid, and battery electric powertrains using less than 1 Hz data. Techniques to upsample lower frequency drive cycle data in order to increase accuracy are also explored. Median energy consumption errors when simulating energy consumption for a 1/10 Hz trajectory are found to be 3-6% when compared to 1 Hz trajectories. Applying upsampling and interpolation techniques are shown to reduce the simulation errors by roughly 50%. The findings in this work can guide connected vehicle data collection specifications and processing techniques applied when using collected data for powertrain simulation.

ADVANCED PROPULSION SYSTEMS↗

Design and Validation of Control Room Upgrades Using a Research Simulator Facility

Since 1981, the United States (U.S.) Nuclear Regulatory Commission (NRC) [1] requires a plant- specific simulator facility for use in training at U.S. nuclear power plants (NPPs). These training simulators are in near constant use for training and qualification of licensed NPP operators. In the early 1980s, the Halden Man-Machine Laboratory (HAMMLab) at the Halden Reactor Project (HRP) in Norway first built perhaps the most well known set of research simulators. The HRP offered a high- fidelity simulator facility in which the simulator is functionally linked to a specific plant but in which the human-machine interface (HMI) may differ from that found in the plant. As such, HAMMLab incorporated more advanced digital instrumentation and controls (I&C) than the plant, thereby giving it considerable interface flexibility that researchers took full advantage of when designing and validating different ways to upgrade NPP control rooms. Several U.S. partners—the U.S. NRC, the Electrical Power Research Institute (EPRI), Sandia National Laboratories, and Idaho National Laboratory (INL) – as well as international members of the HRP, have been working with HRP to run control room simulator studies. These studies, which use crews from Scandinavian plants, are used to determine crew behavior in a variety of normal and off-normal plant operations. The findings have ultimately been used to guide safety considerations at plants and to inform advanced HMI design—both for the regulator and in industry. Given the desire to use U.S. crews of licensed operators on a simulator of a U.S. NPP, there is a clear need for a research simulator facility in the U.S. There is no general-purpose reconfigurable research oriented control room simulator facility in the U.S. that can be used for a variety of studies, including the design and validation of control room upgrades.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Necessity for Iteration in the Application of Numerical Simulation to EGS: Examples from the EGS Collab Test Bed 1

The United States Department of Energy, Geothermal Technologies Office (GTO) is funding a collaborative investigation of enhanced geothermal systems (EGS) processes at the meso-scale. This study, referred to as the EGS Collab project, is a unique opportunity for scientists and engineers to investigate the creation of fracture networks and circulation of fluids across those networks under in-situ stress conditions. The EGS Collab project is envisioned to comprise three experiments and the site for the first experiment is on the 4850 Level in phyllite of the Precambrian Poorman formation, at the Sanford Underground Research Facility, located at the former Homestake Gold Mine, in Lead, South Dakota. Principal objectives of the project are to develop a number of intermediate-scale field sites and to conduct well-controlled in situ experiments focused on rock fracture behavior and permeability enhancement. Data generated during these experiments will be compared against predictions of a suite of computer codes specifically designed to solve problems involving coupled thermal, hydrological, geomechanical, and geochemical processes. Comparisons between experimental and numerical simulation results will provide code developers with direction for improvements and verification of process models, build confidence in the suite of available numerical tools, and ultimately identify critical future development needs for the geothermal modeling community. Moreover, conducting thorough comparisons of models, modelling approaches, measurement approaches and measured data, via the EGS Collab project, will serve to identify techniques that are most likely to succeed at the Frontier Observatory for Research in Geothermal Energy (FORGE), the GTO's flagship EGS research effort. As noted, outcomes from the EGS Collab project experiments will serve as benchmarks for computer code verification, but numerical simulation additionally plays an essential role in designing these meso-scale experiments. This paper reviews specific numerical simulations supporting the design of experiments within Test Bed 1, a volume of phyllite rock under in-situ stress conditions off the western side of the West Access Drift on the 4850 Level, near Governor's Corner. Numerical simulations were executed prior to the start of hydraulic stimulation activities within Test Bed 1 following standard practices, using best estimates of principal stress conditions, thermal conditions, and the rock petrophysical properties, including geomechanical properties. These simulations indicated notching of the borehole would promote the initiation of transverse fractures, seismic magnitudes during the hydraulic stimulation would be below 0.1 magnitude on the Richter scale, a rock thermal conductivity of 5.0 W/m K yielded agreement with kISMET borehole temperature logs, back pressure on the production borehole would increase circulation across the test bed, and the production borehole would serve to halt propagation of the hydraulic fracture to the drift. Pre-existing natural fractures, heterogeneities in the rock properties, monitoring boreholes, and overlooked mine elements have prompted a second look at numerically modeling stimulation, fluid circulation, tracer migration, and thermal breakthrough. Numerical simulation is an invaluable tool for providing insight and understanding to complex physical processes. The success of simulations, however, often depends on including all of the salient features of the system in the founding conceptual model. This paper takes a retrospective look at examples where the conceptual model and simulation was sufficient to provide accurate forecasts and those where elements were missing, necessitating rethinking of the simulation.

15 GEOTHERMAL ENERGY↗

The Necessity for Iteration in the Application of Numerical Simulation to EGS: Examples from the EGS Collab Test Bed 1

The United States Department of Energy, Geothermal Technologies Office (GTO) is funding a collaborative investigation of enhanced geothermal systems (EGS) processes at the meso-scale. This study, referred to as the EGS Collab project, is a unique opportunity for scientists and engineers to investigate the creation of fracture networks and circulation of fluids across those networks under in-situ stress conditions. The EGS Collab project is envisioned to comprise three experiments and the site for the first experiment is on the 4850 Level in phyllite of the Precambrian Poorman formation, at the Sanford Underground Research Facility, located at the former Homestake Gold Mine, in Lead, South Dakota. Principal objectives of the project are to develop a number of intermediate-scale field sites and to conduct well-controlled in situ experiments focused on rock fracture behavior and permeability enhancement. Data generated during these experiments will be compared against predictions of a suite of computer codes specifically designed to solve problems involving coupled thermal, hydrological, geomechanical, and geochemical processes. Comparisons between experimental and numerical simulation results will provide code developers with direction for improvements and verification of process models, build confidence in the suite of available numerical tools, and ultimately identify critical future development needs for the geothermal modeling community. Moreover, conducting thorough comparisons of models, modelling approaches, measurement approaches and measured data, via the EGS Collab project, will serve to identify techniques that are most likely to succeed at the Frontier Observatory for Research in Geothermal Energy (FORGE), the GTO’s flagship EGS research effort. As noted, outcomes from the EGS Collab project experiments will serve as benchmarks for computer code verification, but numerical simulation additionally plays an essential role in designing these meso-scale experiments. This paper reviews specific numerical simulations supporting the design of experiments within Test Bed 1, a volume of phyllite rock under in-situ stress conditions off the western side of the West Access Drift on the 4850 Level, near Governor’s Corner. Numerical simulations were executed prior to the start of hydraulic stimulation activities within Test Bed 1 following standard practices, using best estimates of principal stress conditions, thermal conditions, and the rock petrophysical properties, including geomechanical properties. These simulations indicated notching of the borehole would promote the initiation of transverse fractures, seismic magnitudes during the hydraulic stimulation would be below 0.1 magnitude on the Richter scale, a rock thermal conductivity of 5.0 W/m K yielded agreement with kISMET borehole temperature logs, back pressure on the production borehole would increase circulation across the test bed, and the production borehole would serve to halt propagation of the hydraulic fracture to the drift. Pre-existing natural fractures, heterogeneities in the rock properties, monitoring boreholes, and overlooked mine elements have prompted a second look at numerically modeling stimulation, fluid circulation, tracer migration, and thermal breakthrough. Numerical simulation is an invaluable tool for providing insight and understanding to complex physical processes. The success of simulations, however, often depends on including all of the salient features of the system in the founding conceptual model. This paper takes a retrospective look at examples where the conceptual model and simulation was sufficient to provide accurate forecasts and those where elements were missing, necessitating rethinking of the simulation.

numerical simulation, EGS Collab, enhanced geother↗

High Performance Computing Traffic Simulations for Real-Time Traffic Control of Mobility in Chattanooga Region

In 2019, highway congestion wasted over 3 billion gallons of fuel and caused 8.8 billion hours of lost productivity.1 Research has shown that introducing near-real time traffic controls can significantly reduce congestion. Validated and calibrated traffic simulations enable the modeling of transportation systems and the evaluation of different traffic control actions and schemes given a variety of circumstances that represent likely future scenarios. The developed scenarios can inform the deployment of controls in near real-time to improve freight and passenger vehicle congestion and energy use. In this work, we present simulations used to model the traffic in the Chattanooga, Tennessee, metropolitan area. Simulations were constructed and calibrated using a variety of local, data science enhanced, data sources utilizing open source software including the Simulation of Urban Mobility (SUMO) simulator. High-Performance Computing (HPC) provides a scalable platform with enough computing for the high-fidelity simulation of many scenarios and the application of advance data science especially for large-scale systems. Our simulations include microscopic simulations at a corridor level for traffic signal control, and mesoscopic simulations to evaluate regional operational controls and infrastructure.

97 MATHEMATICS AND COMPUTING↗

Demonstrating integration of CBP and ASCEM simulation tools - 15627

DOE-EM is supporting two crosscutting projects to develop software and conduct targeted experiments to enhance performance and risk assessment capabilities: the Cementitious Barriers Partnership (CBP) and the Advanced Simulation Capability for Environmental Management (ASCEM). The CBP is a smaller-scale project of coordinated software development and experimentation focused on cementitious materials. ASCEM is a larger-scale project aimed at developing next-generation, science-based, reactive flow and transport simulation capabilities and supporting modeling tool-sets within a high-performance computing framework to address DOE-EM's waste management and environmental cleanup challenges. Complementary integration of CBP and ASCEM software tool-sets has been demonstrated through a joint simulation of radionuclide release and transport in a representative tank closure scenario. Specialized CBP capabilities for simulating reactive transport in cementitious materials were utilized in a near-field simulation of radionuclide leaching from the engineered system. The high-performance computing (HPC) capabilities of the ASCEM Amanzi simulator were utilized to simulate far-field flow and transport in the natural environment outside the closed tank. The ASCEM flow simulation provided boundary conditions to the CBP near-field model, which in turn provided radionuclide source terms to the ASCEM far-field transport simulation. The joint demonstration illustrates how the two crosscutting projects can be used in a complementary manner to enhance DOE performance and risk assessment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗