Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Progresses in Ab Initio QM/MM Free Energy Simulations of Electrostatic Energies in Proteins: Accelerated QM/MM Studies of pKa, Redox Reactions and Solvation Free Energies

Hybrid quantum mechanical / molecular mechanical (QM/MM) approaches have been used to provide a general scheme for chemical reactions in proteins. However, such approaches still present a major challenge to computational chemists, not only because of the need for very large computer time in order to evaluate the QM energy but also because of the need for propercomputational sampling. This review focuses on the sampling issue in QM/MM evaluations of electrostatic energies in proteins. We chose this example since electrostatic energies play a major role in controlling the function of proteins and are key to the structure-function correlation of biological molecules. Thus, the correct treatment of electrostatics is essential for the accurate simulation of biological systems. Although we will be presenting here different types of QM/MM calculations of electrostatic energies (and related properties), our focus will be on pKa calculations. This reflects the fact that pKa of ionizable groups in proteins provide one of the most direct benchmarks for the accuracy of electrostatic models of macromolecules. While pKa calculations by semimacroscopic models have given reasonable results in many cases, existing attempts to perform pKa calculations using QM/MM-FEP have led to large discrepancies between calculated and experimental values. In this work, we accelerate our QM/MM calculations using an updated mean charge distribution and a classical reference potential. We examine both a surface residue (Asp3) of the bovine pancreatic trypsin inhibitor, as well as a residue buried in a hydrophobic pocket (Lys102) of the T4-lysozyme mutant. We demonstrate that by using this approach, we are able to reproduce the relevant sidechain pKas with an accuracy of 3 kcal/mol. This is well within the 7 kcal/mol energy difference observed in studies of enzymatic catalysis, and is thus sufficient accuracy to determine the main contributions to the catalytic energies of enzymes. We also provide an overall perspective of the potential of QM/MM calculations in general evaluations of electrostatic free energies, pointing out that our approach should provide a very powerful and accurate tool to predict the electrostatics of not only solution but also enzymatic reactions, as well as the solvation free energies of even larger systems, such as nucleic acid bases incorporated into DNA.

59 BASIC BIOLOGICAL SCIENCES↗

Pumped Storage Hydro Model Evaluation Report Task 1: Tool Assessment

Pumped storage hydro (PSH) projects support various aspects of power system operations. However, determining the value of PSH projects and the many services and contributions to the system they provide can be a challenge. The PSH techno-economic studies being carried out by a 5-lab consortium are defining extensive modeling approaches for evaluating the economic benefits of PSH projects. To enhance the impact of the valuation approach and follow-on techno-economic studies, Pacific Northwest National Laboratory (PNNL) will be developing a set of online tools that industry could adopt and use to advance PSH projects in the US. The problem is that the research team is not entirely clear on the features of the tools that would offer the most significant impact to industry. Thus, year one of this effort is designed to first define the needs of industry before developing the PSH valuation tool. The first step in defining industry needs is to evaluate existing tool packages, including those created by DOE and those by industry groups, to both measure usage levels and define tool attributes that maximize industry impact. The second step in this process will be to hold a workshop designed to elicit direct industry input. Given the breadth and nature of the task, which is to define ideal model attributes, the research team did not constrain the assessment to storage valuation tools. Several tools were assessed, and their characteristics compared against a list of “ideal” attributes that included ease of use, generalizability of results, and analytical flexibility. Information regarding usage and impact were then compared to specific model attributes to define which attributes appear to drive success. The following key lessons and implications can be drawn from the analysis: Models with high ease of use were often the most adopted by industry, though they did not necessarily have high publication reference records, meaning a published article made direct reference to the tool. For example, REScheck TM and COMcheck TM , two tools which share a site, have seen a high amount of web traffic and usage. Similarly, Storage Value Estimate Tool (StorageVET®), an energy storage valuation model, has a large number of organizations using it despite a low publication reference record. A common feature between these models is that they are web-hosted, theoretically making them more easily accessible with graphic user interfaces (GUIs) that are more navigable; Models with higher usage statistics were typically free and/or open source. While it may be unsurprising that this attribute could be considered a draw for users, there is the potential for overestimating the tool's value based on popularity due to the fact that some users may have used the model simply because it was free and not because it is the best model; Models that offer more in-depth analysis and a wide coverage of applications (e.g. VOLTTRON™, GridLAB-D™, and Integrated Valuation of Ecosystem Services and Tradeoffs (InVest)) have shown a high number of publication references as well as showing a high number of downloads in the case of GridLAB-D™. It should be noted that the figure below does not include the model with the highest number of publication references (EnergyPlus™) as it has been removed to show clearer distinction between the remaining tools; The most popular model within the evaluation list was EnergyPlus™. This tool has the highest number of publication references (2,034) of all models considered and contains both a high ease of use level as well as broad application flexibility. Its high usage may be correlated, however, with the presumed wider audience conducting energy consumption modeling compared to the audiences for some of the other tools in this list; Models that were low in both general usage and publication reference generally did not exhibit characteristics considered ideal by the research team. Some of these models offered a narrower range of analytical applications or lower generalizability of results. This would automatically restrict the pool of potential users to those who fall within a narrow range of specific technologies or applications. This report also explores two model structures for the PSH tool: decision tree-based, which would guide the user through the valuation methods defined in the PSH techno-economic studies currently being carried out by DOE, and an all-inclusive comprehensive model. The strengths of each were explored and a hybrid approach was defined that would embed a price taker model into the decision tree approach. Such an approach would provide a comprehensive approach for modeling small-scale PSH while recognizing the challenges associated with implementing a price-maker approach in an all-inclusive model. Insight gained in this analysis of other models can aid in narrowing down the list of effective and sought-after attributes, and in defining model structure. Next steps toward developing a model for storage valuation will be to gain direct industry input through workshops.

13 HYDRO ENERGY↗

The NUBASE2020 evaluation of nuclear physics properties *

The NUBASE2020 evaluation contains the recommended values of the main nuclear physics properties for all nuclei in their ground and excited, isomeric (T-1/2 >= 100 ns) states. It encompasses all experimental data published in primary (journal articles) and secondary (mainly laboratory reports and conference proceedings) references, together with the corresponding bibliographical information. In cases where no experimental data were available for a particular nuclide, trends in the behavior of specific properties in neighboring nuclei were examined and estimated values are proposed. Evaluation procedures and policies that were used during the development of this evaluated nuclear data library are presented, together with a detailed table of recommended values and their uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-F-BRD-10: Lung IMRT Planning Using Standardized Beam Bouquet Templates

Purpose: We investigate the feasibility of choosing from a small set of standardized templates of beam bouquets (i.e., entire beam configuration settings) for lung IMRT planning to improve planning efficiency and quality consistency, and also to facilitate automated planning. Methods: A set of beam bouquet templates is determined by learning from the beam angle settings in 60 clinical lung IMRT plans. A k-medoids cluster analysis method is used to classify the beam angle configuration into clusters. The value of the average silhouette width is used to determine the ideal number of clusters. The beam arrangements in each medoid of the resulting clusters are taken as the standardized beam bouquet for the cluster, with the corresponding case taken as the reference case. The resulting set of beam bouquet templates was used to re-plan 20 cases randomly selected from the database and the dosimetric quality of the plans was evaluated against the corresponding clinical plans by a paired t-test. The template for each test case was manually selected by a planner based on the match between the test and reference cases. Results: The dosimetric parameters (mean±S.D. in percentage of prescription dose) of the plans using 6 beam bouquet templates and those of the clinical plans, respectively, and the p-values (in parenthesis) are: lung Dmean: 18.8±7.0, 19.2±7.0 (0.28), esophagus Dmean: 32.0±16.3, 34.4±17.9 (0.01), heart Dmean: 19.2±16.5, 19.4±16.6 (0.74), spinal cord D2%: 47.7±18.8, 52.0±20.3 (0.01), PTV dose homogeneity (D2%-D99%): 17.1±15.4, 20.7±12.2 (0.03).The esophagus Dmean, cord D02 and PTV dose homogeneity are statistically better in the plans using the standardized templates, but the improvements (<5%) may not be clinically significant. The other dosimetric parameters are not statistically different. Conclusion: It's feasible to use a small number of standardized beam bouquet templates (e.g. 6) to generate plans with quality comparable to that of clinical plans. Partially supported by NIH/NCI under grant #R21CA161389 and a master research grant by Varian Medical System.

60 APPLIED LIFE SCIENCES↗

Joint transform correlation with the synthetic estimation filter

The synthetic estimation filter (SEF) combines a set of input images into a much smaller set of filters. Those input images correspond to views of a known object taken with a variety of values of the pose parameter to be estimated. The response of the filter to variations in the pose parameter is tailored so that estimation can be done to a precision considerably finer than the intervals between filters in the pose space. The technique is extended to the joint transform correlator; as a reference, the composite image from which the SEF is conventionally calculated is used. Precautions are necessary for practical reasons. For example, the SEF algorithm may call for negative values in the image, an unrealizable condition with amplitude encoding, whereas with phase-mostly filtering in the SEF, negative image values are easily accommodated.

Monroe, Stanley E., Jr.↗

Earth Global Reference Atmospheric Model 2007 (Earth-GRAM07)

GRAM is a Fortran software package that can run on a variety of platforms including PC's. GRAM provides values of atmospheric quantities such as temperature, pressure, density, winds, constituents, etc. GRAM99 covers all global locations, all months, and heights from the surface to approx. 1000 km). Dispersions (perturbations) of these parameters are also provided and are spatially and temporally correlated. GRAM can be run in a stand-alone mode or called as a subroutine from a trajectory program. GRAM07 is diagnostic, not prognostic (i.e., it describes the atmosphere, but it does not forecast). The source code is distributed free-of-charge to eligible recipients.

Leslie, Fred W.↗

Sooting Limits Of Diffusion Flames With Oxygen-Enriched Air And Diluted Fuel

Oxygen-enhanced combustion permits certain benefits and flexibility that are not otherwise available in the design of practical combustors, as discussed by Baukal. The cost of pure and enriched oxygen has declined to the point that oxygen-enhanced combustion is preferable to combustion in air for many applications. Carbon sequestration is greatly facilitated by oxygen enrichment because nitrogen can be eliminated from the product stream. For example, when natural gas (or natural gas diluted with CO2) is burned in pure oxygen, the only significant products are water and CO2. Oxygen-enhanced combustion also has important implications for soot formation, as explored in this work. We propose that soot inception in nonpremixed flames requires a region where C/O ratio, temperature, and residence time are above certain critical values. Soot does not form at low temperatures, with the threshold in nonpremixed flames ranging from about 1250-1650 K, a temperature referred to here as the critical temperature for soot inception, Tc. Soot inception also can be suppressed when residence time is short (equivalently, when the strain rate in counterflow flames is high). Soot induction times of 0.8-15 ms were reported by Tesner and Shurupov for acetylene/nitrogen mixtures at 1473 K. Burner stabilized spherical microgravity flames are employed in this work for two main reasons. First, this configuration offers unrestricted control over convection direction. Second, in steady state these flames are strain-free and thus can yield intrinsic sooting limits in diffusion flames, similar to the way past work in premixed flames has provided intrinsic values of C/O ratio associated with soot inception limits.

Sunderland, P. B.↗

MO-FG-CAMPUS-JeP3-03: Detection of Unpredictable Patient Movement During SBRT Using a Single KV Projection of An On-Board CBCT System: Simulation Study

Purpose: An unpredictable movement of a patient can occur during SBRT even when immobilization devices are applied. In the SBRT treatments using a conventional linear accelerator detection of such movements relies heavily on human interaction and monitoring. This study aims to detect such positional abnormalities in real-time by assessing intra-fractional gantry mounted kV projection images of a patient’s spine. Methods: We propose a self-CBCT image based spine tracking method consisting of the following steps: (1)Acquire a pre-treatment CBCT image; (2)Transform the CBCT volume according to the couch correction; (3)Acquire kV projections during treatment beam delivery; (4)Simultaneously with each acquisition generate a DRR from the CBCT volume based-on the current projection geometry; (5)Perform an intensity gradient-based 2D registration between spine ROI images of the projection and the DRR images; (6)Report an alarm if the detected 2D displacement is beyond a threshold value. To demonstrate the feasibility, retrospective simulations were performed on 1,896 projections from nine CBCT sessions of three patients who received lung SBRT. The unpredictable movements were simulated by applying random rotations and translations to the reference CBCT prior to each DRR generation. As the ground truth, the 3D translations and/or rotations causing >3 mm displacement of the midpoint of the thoracic spine were regarded as abnormal. In the measurements, different threshold values of 2D displacement were tested to investigate sensitivity and specificity of the proposed method. Results: A linear relationship between the ground truth 3D displacement and the detected 2D displacement was observed (R{sup 2} = 0.44). When the 2D displacement threshold was set to 3.6 mm the overall sensitivity and specificity were 77.7±5.7% and 77.9±3.5% respectively. Conclusion: In this simulation study, it was demonstrated that intrafractional kV projections from an on-board CBCT system have a potential to detect unpredictable patient movement during SBRT. This research is funded by Interfractional Imaging Research Grant from Elekta.

60 APPLIED LIFE SCIENCES↗

Perspective on Kramers symmetry breaking and restoration in relativistic electronic structure methods for open-shell systems

Without rigorous symmetry constraints, solutions to approximate electronic structure methods may artificially break symmetry. In the case of the relativistic electronic structure, if time-reversal symmetry is not enforced in calculations of molecules not subject to a magnetic field, it is possible to artificially break Kramers degeneracy in open shell systems. This leads to a description of excited states that may be qualitatively incorrect. Despite this, different electronic structure methods to incorporate correlation and excited states can partially restore Kramers degeneracy from a broken symmetry solution. For single-reference techniques, the inclusion of double and possibly triple excitations in the ground state provides much of the needed correction. Formally, however, this imbalanced treatment of the Kramers-paired spaces is a multi-reference problem, and so methods such as complete-active-space methods perform much better at recovering much of the correct symmetry by state averaging. Using multi-reference configuration interaction, any additional corrections can be obtained as the solution approaches the full configuration interaction limit. A recently proposed “Kramers contamination” value is also used to assess the magnitude of symmetry breaking.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A new HALEU isotopic certified reference material

Candidate certified reference material (CRM) U196 was prepared by gravimetrically mixing and dissolving NNSA NRMP CRM 112-A (natural uranium metal) and CRM 116-A (highly enriched 93.2% 235 U metal) to achieve a high-assay low-enriched uranium (HALEU) isotopic abundance reference material. CRM U196 will be certified for the 233 U/ 238 U, 234 U/ 238 U, 235 U/ 238 U, and 236 U/ 238 U ratios. Gravimetrically determined uranium isotope amount ratios and values derived from the isotope data were calculated from the buoyancy corrected mass data and from certified values for the metal CRMs used to create the solution. The 235 U isotope amount fraction (·100) and expanded uncertainty is 19.5846 ± 0.0028. For attribute verification, total evaporation and modified total evaporation isotope ratio measurements were performed. In conclusion, the reference material is to be distributed as a unit containing 5 mg uranium as dry uranyl nitrate.

High-assay low-enriched uranium↗

Distribution Development for the RDX Regional Model at Los Alamos National Laboratory - 20385

Representing uncertainty in model inputs often means finding a balance between uncertainty and physical reality. Developing wide distributions may seem conservative in principle, but this approach may lead to unrealistic model results. Characterizing the current state of knowledge of stochastic inputs presents many challenges, especially if the data available are limited or have limited relevance to the site. Relationships among these inputs may also be important to represent but are typically complex or difficult to define. Often special adjustments must be made to account for reduced credibility in particular data. If parameters are strongly related to one another, a correlation structure may be developed for input to the model. Other techniques such as regression models may be used to incorporate relationships between the information available and the desired parameters. The process of developing distributions must consider details of the model in terms of what the distribution is meant to represent. This paper uses the example of a probabilistic fate and transport model for hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) in the regional aquifer at Los Alamos National Laboratory (LANL). For many parameters, a single draw is applied to all space and time over which the model is run, for a single iteration. This simplification is often made for many reasons, and can often be beneficial, but also adds additional complexity in the distribution development process. Defining the distributional goals as they relate to the modeling process is an important step, which should take place prior to evaluation of the data. Usually, the distributions developed are meant to characterize the average value of the parameter over the spatial and temporal domain of the model. Distribution development requires consideration of many sources of information on the parameter where available, ideally from multiple references. Examples of different sources include data from different references but also from different conditions, measurement methods, or experimental types. Depending on these conditions and the reliability or relevance of particular references, different sources of data may each contribute valuable information but have varying relevance to the site. In these cases, weighting data unequally is a useful way to incorporate this information. As an example, aqueous dispersivity data are available for a variety of rock types. Only a few values are available for the desired rock type, and this is not enough to develop a distribution. Therefore, dispersivity values from other rock types are included in distribution development but are down-weighted such that the best data have the most influence on the distribution developed. In another case, K{sub d} distributions in the model are meant to represent a known composition of multiple soil types. Data from these materials are weighted accordingly to develop a distribution for the weighted average K{sub d} across soil types. Other cases include varying reliability of different sources, and weighting data according to the confidence in these sources. In some cases, input parameters are correlated with one another. An example is advective porosity, which is positively correlated with total porosity and must be less than total porosity. Paired data with both parameters must exist to discern the relationship between the two parameters and if it is necessary to build a correlation structure into the model. In general, correlated parameters may be represented in the model by a multivariate distribution, or perhaps more desirably, capturing the correlation within the developed distributions which may be treated as independent from one another. In the example of porosity, this can be done by transforming advective porosity into a proportion of total porosity which may be drawn independently from the distribution of total porosity. This paper explores how complex data and correlations can be incorporated to meet the distributional goals of the model, using the RDX regional model as a detailed example. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-T-471: Small Field Jaw/MLC Reference Data

Purpose: In recent years the need for small field data of MLCs has increased due to the use of intensity-modulated radiation (IMRT), but moreover the use of stereotactic body radiation (SBRT) has increased, which uses not simply small field sizes, but small jaw and field sizes together. Having reference data for these small fields that is reliable would be invaluable to the physics community. Our study has gathered these values and the data distributions from the Radiological Physics Center's (RPC) site visits between 1990 and the present. Methods: For all measurements, the RPC used a 25 × 25 × 25cm water phantom placed at 100cm SSD. All measurements were made with an Exradin A16 cylindrical ion chamber at an effective depth of 10 cm. A total of 42 Varian machine measurements were used to compose the data for a 6 MV beam and 5 TrueBeam 6 MV flattening filter free (FFF) beams were used for FFF data. Results: Jaw/MLC fields were measured for both 6 MV and 6 MF FFF beams with the jaws and MLCs both at the following field sizes: 6×6, 4×4, 3×3, and 2×2cm. Measurements were normalized to the 10×10 field readings (defined by the jaws and MLC). Spread in the data was minimal and demonstrates a high level of accuracy of acquired data. Conclusion: Small field Jaw/MLC reference data for Varian 6MV and 6 MV FFF beams has been analyzed and presented here, composed of the aggregation of numerous RPC site visits. Obtaining reliable small field data remains difficult, however the RPC has collected high fidelity small field Jaw/MLC data. The data are presented as a reference along with their distributions, in such a way that the physicist can act based upon their own desired agreement with the reference data.

60 APPLIED LIFE SCIENCES↗

SU-F-19A-02: Comparison of Absorbed Dose to Water Standards for HDR Ir-192 Brachytherapy Between the LCR, Brazil and NRC, Canada

Purpose: To compare absorbed dose to water standards for HDR brachytherapy dosimetry developed by the Radiological Science Laboratory of Rio de Janeiro State University (LCR) and the National Research Council, Canada (NRC). Methods: The two institutions have separately developed absorbed dose standards based on the Fricke dosimetry system. There are important differences between the two standards, including: preparation and read-out of the Fricke solution, irradiation geometry of the Fricke holder in relation to the Ir-192 source, and determination of the G-value to be used at Ir-192 energies. All measurements for both standards were made directly at the NRC laboratory (i.e., no transfer instrument was used) using a single Ir-192 source (microSelectron v2). In addition, the NRC group has established a self-consistent method to determine the G-value for Ir-192, based on an interpolation between G-values obtained at Co-60 and 250kVp X-rays, and this measurement was repeated using the LCR Fricke solution to investigate possible systematic uncertainties. Results: G-values for Co-60 and 250 kVp x-rays, obtained using the LCR Fricke system, agreed with the NRC values within 0.5 % and 1 % respectively, indicating that the general assumption of universal G-values is appropriate in this case. The standard uncertainty in the determination of G for Ir-192 is estimated to be 0.6 %. For the comparison of absorbed dose measurements at the reference point for Ir-192 (1 cm depth in water, perpendicular to the seed long-axis), the ratio Dw(NRC)/Dw(LCR) was found to be 1.011 with a combined standard uncertainty of 1.7 %, k=1. Conclusion: The agreement in the absorbed dose to water values for the LCR and NRC systems is very encouraging. Combined with the lower uncertainty in this approach compared to the present air-kerma approach, these results reaffirm the use of Fricke solution as a potential primary standard for HDR Ir-192 brachytherapy.

07 ISOTOPE AND RADIATION SOURCES↗

Distribution of Pb-210 in Spanish Soils: Study of the Atmospheric Contribution

The vertical distribution of activity and inventories of atmospheric Pb-210 is being studied in Spanish soils, aiming to establish the reference levels in the zone, based on the type of soil and the annual rainfall. A homogeneous distribution grid (approx. 150x150 km each cell) has been established covering the peninsular land, trying to combine the varying soil types (remaining undisturbed for the last 50 years) and the closeness to meteorological stations. Sampling has been performed by extracting undisturbed soil cylinders of 6 cm diameter and 120 cm length, with an impact penetrometer, and the soil cores have been sectioned in slices of 3 cm thick. The analysis of Pb-210 has been performed using a gamma spectrometry system with coaxial HPGe detector sensitive at low energies (46.5 keV emission). The geometry of measured samples is thin enough (approx. 2 cm) to minimize self-absorption corrections. The work presents the results obtained so far. The Pb-210 activity profiles exhibit the characteristic decreasing shape with depth, showing maximum levels at the surface, and reaching the equilibrium activity with Ra-226 at a maximum depth depending on different environmental conditions. The unsupported Pb-210 inventory values are in the usual range (1000-5000 Bq/m{sup 2}), showing a positive correlation with the averaged annual rainfall. These reference levels could be used in posterior studies of anthropogenic alteration of soils, evaluation of erosion and desertification processes.

54 ENVIRONMENTAL SCIENCES↗

Scale-Dependent Value of QPF for Real-Time Streamflow Forecasting

Incorporating rainfall forecasts into a real-time streamflow forecasting system extends the forecast lead time. Since quantitative precipitation forecasts (QPFs) are subject to substantial uncertainties, questions arise on the trade-off between the time horizon of the QPF and the accuracy of the streamflow forecasts. This study explores the problem systematically, exploring the uncertainties associated with QPFs and their hydrologic predictability. The focus is on scale dependence of the trade-off between the QPF time horizon, basin-scale, space-time scale of the QPF, and streamflow forecasting accuracy. To address this question, the study first performs a comprehensive independent evaluation of the QPFs at 140 U.S. Geological Survey (USGS) monitored basins with a wide range of spatial scales (~10 – 40,000 km 2 ) over the state of Iowa in the Midwestern United States. The study uses High-Resolution Rapid Refresh (HRRR) and Global Forecasting System (GFS) QPFs for short and medium-range forecasts, respectively. Using Multi-Radar Multi-Sensor (MRMS) quantitative precipitation estimate (QPE) as a reference, the results show that the rainfall-to-rainfall QPF errors are scale-dependent. The results from the hydrologic forecasting experiment show that both QPFs illustrate clear value for real-time streamflow forecasting at longer lead times in the short- to medium-range relative to the no-rain streamflow forecast. The value of QPFs for streamflow forecasting is particularly apparent for basin sizes below 1,000 km 2 . The space-time scale, or reference time t r ) (ratio of forecast lead time to basin travel time) ~ 1 depicts the largest streamflow forecasting skill with a systematic decrease in forecasting accuracy for t r > 1.

54 ENVIRONMENTAL SCIENCES↗

2023 Central Hanford Ecological Integrity Assessments Monitoring Report

The Hanford Site is comprised of an expanse of shrub-steppe habitats that provides exceptional ecological value to plants and animals located on the site and in the surrounding greater Columbia Basin. The U.S. Department of Energy (DOE)-managed portion of the Hanford Site, referred to from here on as Central Hanford, has been the focus of various ecological monitoring efforts, including vegetation monitoring. The scope and goals of vegetation surveys have varied greatly since the Hanford Site was established, but previous studies have documented a rapidly changing landscape, making it clear that continued vegetation monitoring is integral to preserving the ecological value of Central Hanford. A new vegetation monitoring effort was initiated in 2023 using methods based on ecological integrity assessments (EIA) (Natural Heritage Report [NHR] 2020-05) developed by the Washington Natural Heritage Program (WNHP), a division of the Washington State Department of Natural Resources (DNR) and NatureServe®. The methods were modified and supplemented to meet monitoring goals at the Hanford Site. The 2023 EIA monitoring effort consisted of field surveys to evaluate vegetation and soil condition across Central Hanford. Surveys were focused on upland habitats, and areas under consideration for upcoming projects were prioritized. Vegetation cover estimates were used to score a variety of metrics for vegetation conditions in each area. In 2023, approximately half of the site was surveyed. Monitoring methods and results for the 2023 field season are summarized in this report, and management recommendations are also provided.

54 ENVIRONMENTAL SCIENCES↗

Automated ICRF heating surrogate modeling via machine learning

This work introduces automated machine learning workflows that address critical bottlenecks in surrogate model development for Ion Cyclotron Range of Frequencies (ICRF) heating applications. The automated framework includes data analysis tools that transform raw datasets into actionable insights in seconds, replacing weeks of manual exploratory effort and ensuring consistent, reproducible dataset characterization. By integrating advanced hyperparameter optimization (HPO) methods including Bayesian optimization via BoTorch and Tree-structured Parzen Estimators (TPE), the framework significantly reduces model development time from weeks to hours, decreasing computational cost and required expertise, while enabling high-accuracy surrogate models. Compared to traditional hyperparameter scanning (HPS) techniques such as methodical, randomized, and grid searches, HPO methods achieve superior convergence and predictive performance, even when compared to already well-tuned reference models. On NSTX High Harmonic Fast Wave (HHFW) heating datasets, both Random Forest Regressor (RFR) and neural network surrogates demonstrate improved accuracy, achieving R 2 values beyond 0.97 and 0.98, respectively. The results show that while HPO gains are modest for robust architectures like RFR, they become essential for more sensitive models such as neural networks, highlighting the trade-offs across optimization strategies. Through automated workflows that eliminate manual hyperparameter tuning and require minimal ML expertise, this work enables widespread adoption of high-fidelity surrogate models across the fusion community for real-time plasma control, uncertainty quantification, rapid experimental scenario development, and integrated system optimization.

Sanchez-Villar, Alvaro [Princeton Plasma Physics L↗

Interfractional Reproducibility of Lung Tumor Location Using Various Methods of Respiratory Motion Mitigation

Purpose: To determine interfractional reproducibility of the location of lung tumors using respiratory motion mitigation. Methods and Materials: Free-breathing four-dimensional computed tomography (CT) data sets and CT data sets during breath hold were acquired weekly for 17 patients undergoing treatment for non-small-cell lung cancer. Distances between the center of the gross tumor volume (GTV) and a reproducible bony reference point under conditions of breath hold on end inspiration (EI) and end expiration (EE) and during free breathing on the 0% phase (corresponding to EI) and 50% phase (corresponding to EE) were analyzed for interfractional reproducibility. Systematic uncertainties in tumor location were determined as the difference in distance between the GTV center on the first CT data set and the mean location of GTV centers on the subsequent data sets. Random uncertainties in tumor location were determined as the standard deviation of the distances between the GTV centers and the bony reference points. Margins to account for systematic and random interfractional variations were estimated based on these uncertainties. Results: Mean values of interfractional setup uncertainties were as follows: systematic uncertainties-EI, 0.3 cm; EE, 0.2 cm; 0% phase, 0.3 cm; and 50% phase, 0.3 cm; and random uncertainties-EI, 0.3 cm; EE, 0.3 cm; 0% phase, 0.3 cm; and 50% phase, 0.3 cm. There does not appear to be any correlation between uncertainties and GTV size, but there appears to be a weak positive correlation between uncertainties and the magnitude of GTV excursion. Conclusions: Voluntary breath hold and gating on either EI or EE appear to be equally reliable methods of ensuring the reproducibility of lung tumor position. We recommend setup margins of 0.3 cm if using cone-beam CT or kilovoltage X-ray with fiducials and aligning directly to the tumor and 0.8 cm when aligning to a nearby bony surrogate using cone-beam CT or kilovoltage X-ray.

62 RADIOLOGY AND NUCLEAR MEDICINE↗