Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Micromagnet PUF readout using a quantum diamond microscope

A physically unclonable function (PUF) and a method of reading it are provided. The PUF is constituted by a microfabricated array of randomly polarized micromagnets disposed on a substrate. The PUF can be read by creating a magnetization map of the PUF from the signal output of a quantum diamond microscope (QDM) and converting the magnetization map to a numerical sequence.

Kehayias, Pauli Mark↗

Comparing Thick Target Neutron Yield Calculations for Alphas on F-19 using MCNP6 1.1 Beta with TENDL 2012 Libraries

Because of the heritage of MCNPX, the first production release of MCNP6{sup TM} used physics models, instead of ACE (A Compact Evaluated Nuclear Data File) formatted libraries, for simulating the transport of alpha particles at all energies, as MCNPX could not yet read ACE formatted light ion libraries. For non-Coulombic interactions, the physics models have suggested minimums of ∼ 20-200 MeV. The first production release of MCNP6, MCNP6{sup TM} 1.0, was still capable of transporting alphas to low energies; however, the physics models resulted in poor prediction of inelastic reactions at energies below the suggested minimums. This poorer prediction at low energies resulted in orders of magnitude lower neutron yields for events resulting from light ion interactions at low energies. For example, F-19(α,n)Na-22 from U-234 decay in UF{sub 6} produced poor neutron production results. Modeling these types of interactions correctly is vital for signal analysis for nonproliferation safeguards and nuclear security as well as for correctly characterizing source terms for radiation protection and shielding calculations. The TALYS computer code was developed to simulate nuclear reactions involving neutrons, photons, protons, deuterons, tritons, alphas and He-3 particles, in the 1 keV - 200 MeV energy range. TENDL is a nuclear data library, which provides the output of the TALYS nuclear model code system for direct use in applications (i.e. ACE formatted cross sections). Since 2008, TENDL had publicly provided ACE formatted libraries for alpha transport; however, not until the release of MCNP6{sup TM} 1.1 beta, had MCNP6 publicly possessed the capability to read such libraries. At the Radiation Protection and Shielding Division topical meeting in 2014, initial testing of MCNP6 1.1 beta showed that MCNP6 using TENDL 2012 resulted in poor prediction when compared to the compilation of experiment data provided in R. Heaton et al. Further comparisons for PuBe sources, using the MCNP6 1.1 beta spontaneous decay alpha feature coupled with alpha transport, were also given in the winter American Nuclear Society meeting in 2014, where the results showed large discrepancies with measured data. For F-19(α,n)Na-22 interactions, the R. Heaton et al. paper is a conglomeration of several important references; and the data provided by R. Heaton et al. used a numerical fit of the excitation function provided by Norman et al.. Norman et al. has recently published their (α,n) thick target yield data for PbF{sub 2} in tabular form, backing out the thick target yields of F-19(α,n)Na-22 and computing F{sub 2} and UF{sub 6} thick target neutron yields (as supplements to the PbF{sub 2} data). Here we compared measured thick target yields of E. B. Norman et al. to MCNP6 1.1 beta using TENDL 2012 libraries. Deterministically backing out the thick target yield from measured values involves using the stopping power. MCNP uses either the SPAR code or an interpolation of the Spar code and Bethe-Boch formula for computing stopping powers. As a result one may believe that these separate methods will arrive at separate thick target yields independent of the production cross section. In our MCNP calculations, we simulated the alpha until the alpha completely stopped in the medium. The energy loss in the condensed history algorithm is not continuous but discrete and related to the stopping powers. Because the neutron production yield is energy dependent, the energy loss dictates the emission of secondary neutrons; and therefore the difference in stopping powers used may have some slight effect on the yield difference. For this study, we chose to use the default condensed history algorithm setup, while future studies should address tightening steps in the condensed history algorithm to prove whether or not choice of stopping power actually matters. The fact that all 5 evaluated isotopic compositions resulted in different thick target yield percent differences does warrant this type of investigation. A typical user may not be only interested in integral emission, taking 10 s to 100 s of processor hours to simulate, but rather a timely generation of the spectra. Such an application would require biasing the production of secondaries from alpha sources such that millions of secondaries could be produced, emulating a converged energy dependent spectra. Neutron production biasing from alpha sources does not currently exist; however, developing a biasing algorithm for neutron production from alpha sources should be investigated in the future.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

In-Situ Gamma Radiation Mapping Device - 19353

The SRNL developed GrayQb{sup TM} is a passive, low cost gamma radiation mapping device which uses a tungsten pinhole and a phosphor storage plate (PSP) to generate images. Presently, the device requires retrieval to extract images off the PSP using an external scanner. In partnership with Los Alamos National Lab (LANL), SRNL has developed an in-situ GrayQb{sup TM} radiation mapping device eliminating the need to remove the radiation sensitive phosphor storage plate (PSP) from the device for scanning between exposures. By incorporating a customized version of the LANL patented MiniMax camera-based PSP reader system into the GrayQb{sup TM} housing, the exposed PSP can now be read in-situ and digitally transmitted to a remote computer for viewing. In-situ imaging is a valuable addition to GrayQb{sup TM} because of the reduced need of personnel interaction which mitigates risk as well as the option for multiple images being acquired during one deployment. Upgrades implemented which allow for in-situ imaging to be performed include using the tungsten pinhole, a PSP, red LEDs, a blue light filter, and a commercial off the shelf (COTS) color camera. The images are transmitted wirelessly to an external computer. This presentation will discuss the selection, characteristics, and testing of the camera-based PSP reading system, improved PSP materials, and the results/performance of the upgraded GrayQb{sup TM} device. Testing has been performed with simulated radiation exposures as well as A-241 and Cs-137 button sources. These upgrades and tests have been performed over a 12-month period and this presentation will be a summary and conclusion to this year long project. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Gamma Imaging and Mapping Advancements

The SRNL developed GrayQb{sup TM} gamma mapping system has been successfully deployed in field situations. Currently, to get the image from the GrayQb{sup TM} the internal Phosphor Storage Plate (PSP) used to capture radiation images must be recovered and scanned by a ScanX Scanner. Upgrades are being implemented which will enable the GrayQB{sup TM} to read the PSP using a camera and red LEDs then transmit results to a remote location. This will greatly reduce personnel interaction, increasing safety as well as eliminating the need for the ScanX. Upgrades have been based off of the MiniMax, a Los Alamos National Laboratory developed PSP reading device constructed with a Nikon DSLR and a red LED flash to obtain the images from the PSP. The electronics in the upgraded GrayQb{sup TM} need to be both functional and environmentally rugged. A PC/104 was chosen for its wider operational temperature range and its physical durability. The Sony α7 ii and the Mightex are the candidate cameras for the upgrades based on test results. PSPs were exposed to gamma radiation sources at SRS's Health Physics Instrumentation Calibration Laboratory (HPICL). PSPs were tested with both Am-241 and Cs-137. Linear intensity increased with dose verifying UV image simulations. Data collected enabled the PSP intensity to be referenced to a total dose. Further work includes design and implementation of a 3D printed housing for the new camera system. The housing will include the camera, light flash, PSP holders, tungsten dual pinhole, PC/104, dosimeter, and a battery or tethering option. Once the housing is finalized further testing at the HPICL facility is planned for early August. During this testing, the final housing design will capture both Am-241 and Cs-137 images.

3D PRINTING↗

Low Level Calibration of Liquid Scintillation Counting

Liquid Scintillation Counting (LSC) is an analytical laboratory method that quantifies the concentrations of alpha and beta emitting isotopes. The LSC method can be utilized for the detection of tritium, both environmentally and at nuclear facilities. Most LSC samples are aqueous-based and prepared as a radioactive sample dissolved or suspended in a high efficiency scintillation cocktail that converts radioactive energy into light pulses. When placed in counting vials, the liquid scintillation cocktail allows for optical coupling in which energy is released from the samples radioactive decay, and transferred to the scintillator. That energy is then absorbed to produce excited electrons that fall back to their ground-state and emit a pulse of light that is detected by the liquid scintillation analyzers photomultiplier tubes. Quench is a signal attenuation due to physical, chemical, or color interferences. To compensate for quench, quench standards of a known concentration are implemented at increasing increments of quench per vial to create a quench curve. Quench standards can be purchased pre-made or customized from the manufacturer, however, there are several issues that arise from purchasing the pre-made quench standards. The main issues with ordering pre-made quench standards is that they use higher count values, between 30,000 and 250,000 disintegrations per minute (dpm) of tritium per vial and only come in glass vials. Using higher counting standards in glass vials makes it hard to see lower concentrations in plastic vials. Additionally, when using higher energy standards the accuracy of the calibration readings tend to be lower. On the other hand, making a set of quench standards in-house allows for the customization of the dpm concentration to roughly 1,500-3,000 and preparation in plastic vials. This allows for lower activity readings that results in closer precision of the samples' true concentration. Technical Objectives: Create a quench curve and calibrate the LSA for tritium. Verify the calibration of the quench curve prior to cross sample runs. Check calibration against Quality Control (QC) reference value. Conclusion: a tritium quench curve calibration was performed using a scintillation cocktail with ultima gold (AB and AB/F), acetone (only with AB), and water (only with AB/F). By performing the tritium quench curve calibration, the counting efficiency was correlated to various levels of quench. Calibration checks with quality control standards were also performed to verify that the calibration was correct. The observed results provided acceptable values that matched the quality control standard reference values with an acceptable uncertainty. The next step will be fine tuning and cross comparison checks with legacy instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparing Measured (a,n) Thick Target Yields to MCNP6 using TENDL 2012 Libraries - Paper 31

MCNP6, due to the heritage of MCNPX, has always possessed the capability to transport the light ions, such as alpha particles. Two types of competing physics take place during the particle transport: atomic and nuclear physics. Charged particles lose energy to media due to Coulombic interactions. MCNP6 models Coulombic interactions through the use of the continuous slowing down approximation. Stopping powers are calculated at a variety of energies using the Bethe-Bloch formula with Sternheimer and Peierls density effect correction. For energies less than 1.31 MeV/AMU, a low-energy SPAR model is used. When the energy of the particle is high enough, there is a transition from nuclear interactions to nucleon interactions. MCNP6 possess various physics models to account for these types of intra-nuclear cascades. These models are less accurate at low energies. Even though MCNP6 will transport these light ions to low energies (i.e. less than 20 MeV), most of the available model physics in MCNP6, for nuclear interactions, has a suggested minimum energy of ∼20-200 MeV. The result of the poorer prediction at low energies causes important light ion events, such as F-19(a,n)Na-22 from U-234 decay in UF{sub 6}, to produce orders of magnitude fewer neutrons in MCNP6 than should be emitted. As with neutrons, ACE (A Compact ENDF) formatted light ion libraries have been developed from several different evaluations. These libraries possess better physics at low energies where the physics models break down. The TENDL 2012 evaluations possess alpha transport libraries, in ACE format, such that they can easily be used with codes like MCNP6 that read ACE formatted cross sections. As a result, a capability was developed for MCNP6 to read and implement these library cross sections when the light ion reached energies below the library upper energy cutoff. Perfectly modelling an experiment for benchmark comparisons to a code calculation can be tricky. For complex setups, systematic error is always possible; and usually a hefty uncertainty analysis is required to quantify just the geometry setup and material combination choices. For an (a,n) interaction, a thick target yield is defined as the amount of neutrons emitted given that the alpha ranges out in the material. For alpha transport at low energy <10 MeV, in reasonably dense materials (>1-2 g/cc), with a material dimension length larger than a few hundred microns, alpha particles will tend to completely stop and range out in the material. For Li, Be, B, C, N, O, F, Na, Mg and Al thick target yields exist in 200 keV intervals from 1 to 9.8 MeV (most of the elements do have (a,n) thresholds above 1 MeV). Because modelling a thick target yield in MCNP6 is much easier than attempting to account for the complexity of systematic error from a full out experiment, we present here comparisons of (a,n) thick target yields to those calculated in MCNP6 using the TENDL 2012 alpha library evaluations.

61 RADIATION PROTECTION AND DOSIMETRY↗

AMPX: A Modern cross section processing system for generating nuclear data libraries - 14619

Nuclear data libraries are essential for nuclear analysis code systems like SCALE. AMPX has been continuously developed since the early 1970's and is used to generate these data libraries for SCALE. Recently, Oak Ridge National Laboratory (ORNL) initiated a major modernization effort to position AMPX for continued development and deployment on modern computing platforms. An important step toward modernization has been to merge AMPX under the SCALE continuous integration (CI) development framework. As a result, AMPX is now developed under the SCALE software quality assurance plan, providing increased confidence in the quality of data libraries developed and deployed by AMPX. This merge allowed us to develop novel methods to generate self-shielding factors that combine SCALE's resonance self-shielding capabilities with the AMPX library-generation capabilities. AMPX processes Evaluated Nuclear Data Format (ENDF/B) files. The ENDF community is working to develop a more modern format that will replace the existing ENDF/B format. Due to strict space and memory requirements when AMPX was first developed, the original AMPX processing and reading of ENDF data were tightly integrated. On newer computer systems, this is no longer necessary. Now there is a separation between reading and processing which allows for simultaneous support of current and new ENDF formats. As a result, AMPX is positioned to adopt any new ENDF format when available. For end users, the modernization effort has resulted in improved processing capabilities for generating nuclear data libraries. The objective of the paper is to document the latest AMPX cross-section processing capabilities and provide the current status of the AMPX modernization effort. (authors)

42 ENGINEERING↗

Explainable Graph Learning for Particle Accelerator Operations

Particle accelerators are vital tools in physics, medicine, and industry, requiring precise tuning to ensure optimal beam performance. However, real-world deviations from idealized simulations make beam tuning a time-consuming and error-prone process. In this work, we propose an explanation-driven framework for providing actionable insight into beamline operations, with a focus on the injector beamline at the Continuous Electron Beam Accelerator Facility (CEBAF). We represent beamline configurations as heterogeneous graphs, where setting nodes represent elements that human operators can actively adjust during beam tuning, and reading nodes passively provide diagnostic feedback. To identify the most influential setting nodes responsible for differences between any two beamline configurations, our approach first predicts the resulting changes in reading nodes caused by variations in settings, and then learns importance scores that capture the joint influence of multiple setting nodes. Experimental results on real-world CEBAF injector data demonstrate the framework’s ability to generate interpretable insights that can assist human operators in beamline tuning and reduce operational overhead.

Wang, Song [Univ. of Virginia, Charlottesville, VA↗

Validation of Pronghorn for Natural-Circulation Molten Salt Loops

This paper presents the development and validation of a high-fidelity thermal-hydraulic model of a molten salt natural circulation flow loop, designed for integration within a digital twin framework. The study evaluates the performance of Idaho National Laboratory’s Pronghorn against experimental data from Texas A&M University Molten Salt Flow Loop (MSFL) four Hitec-salt test benchmark data. Natural circulation of high-Prandtl-number fluids exhibits complex, counter-intuitive flow patterns that make pointwise thermocouple readings unreliable. Experimental work at TAMU’s MSFL provides benchmark data, including flow visualization at a test-section and centerline steady-state temperature measurements along the loop. Validation includes four single-phase natural circulation test cases with Hitec salt. Key metrics include flow profile agreement and steady-state temperature accuracy. Pronghorn results for two-dimensional single-phase agree qualitatively with the experimental flow profile. This paper illustrates the importance of Computational Fluid Dynamics (CFD) in elucidating the behavior of high-Prandtl-number thermal-hydraulics, along with how misleading centerline temperature measurements can be. Pronghorn reproduces the axial and radial stratification that makes single thermocouple readings unreliable. Future research will focus on reduced-order modeling techniques to enable rapid simulation suitable for real-time digital twin applications. The validated cases provide a basis for developing reduced-order surrogates aimed at real-time digital-twin applications.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Long-term stability-degradation analysis of DUNE SiPMs in Liquid Nitrogen

We developed a cryogenic photon readout system to monitor arrays of DUNE SiPMs operating at various over-voltages in liquid nitrogen (LN2) for over three months. Photoelectron signals were read out simultaneously via weak capacitive coupling to the micro-FEMB, a 32-channel charge sensitive readout board designed for 77 K to 300 K operation in liquid argon time projection chambers (LAr-TPCs). A waveform snippet acquisition scheme was implemented to capture waveform signals whenever they exceeded a predetermined trigger level; consequently, empty waveforms were discarded. Selected SiPM parameters were monitored to detect any deviations beyond statistical fluctuations. While some parameters exhibited ~1σ variations over the 3-month test period, there was no evidence of drift being enhanced when operating at 4 V or 5 V compared to a 3 V over-voltage. However, a discernible PDE drop was observed across all channels, which warrants further investigation. In addition, we demonstrated that our system can simultaneously read out single photons from a selected group of SiPMs at room temperature.

Tsang, Thomas [Brookhaven]↗

Detection of scintillation light in noble gases with wavelength-shifting optical fibers

Wavelength-shifting (WLS) techniques enable particle detectors based on noble gases, whose scintillation light is predominantly emitted in the vacuum-ultraviolet. We investigate WLS fibers coated with tetraphenyl butadiene (TPB) for scintillation light detection in gaseous xenon and argon at pressures up to 8.5 bar, motivated by future high-pressure xenon time-projection chambers of the NEXT program. Two detector configurations are studied: an elongated high-pressure vessel with four PTFE panels equipped with WLS fibers read by temperature-stabilized SiPMs, and a compact box-shaped detector operated at 1 bar Xe with WLS fibers read out by PMTs. Both operate with continuous gas purification. The detector response is characterized using cosmic muons and alpha particles from a $^{241}$Am source. With the SiPM setup, we measure a light collection efficiency (LCE) of ${1.18 \pm 0.01~\mathrm{(sta.)}~^{+0.07}_{-0.09}~\mathrm{(sys.)}~\%}$ for xenon and ${1.07 \pm 0.01~\mathrm{(sta.)}~^{+0.06}_{-0.08}~\mathrm{(sys.)}~\%}$ for argon. With PMT readout, we measure a LCE of ${0.45 \pm 0.01~\mathrm{(sta.)} \pm 0.05~\mathrm{(sys.)}~\%}$ in xenon, in agreement with the SiPM result once photon detection efficiency is accounted for. Average scintillation waveforms in xenon and argon are studied to assess the time structure of the emitted light. Cosmic-muon measurements yield a mean energy required to produce a scintillation photon $45\pm7~\mathrm{(sta.)}~^{+4}_{-5}~\mathrm{(sys.)}~\mathrm{eV}$ at 1.5 bar, in agreement with the literature. The results demonstrate that TPB-coated WLS fiber systems can reliably detect scintillation light in high-pressure gaseous noble detectors, with a LCE representing an upper limit for realistic large-scale TPCs, where additional photon losses from materials and fiber attenuation are expected.

Soleti, S. R. [Donostia Intl. Phys. Ctr., San Seba↗

Exploration of Real Time Inference for MI-RR Deblending on GPU/TPU Systems

The Fermilab Main Injector (MI) and Recycler Ring (RR) share a common beam loss monitor (BLM) system, making loss events difficult to attribute to their source machine when beam is present in both simultaneously. The Real-time Edge AI for Distributed Systems (READS) project addresses this by deblending BLM readings in real time using machine learning (ML). The current FPGA based implementation meets the sub-3 ms latency requirement but carries a resource intensive hls4ml development cycle, motivating exploration of GPU based deployment. This paper characterizes inference latency on an NVIDIA Jetson Orin Nano and introduces a packet organization scheme for assembling synchronized event frames from seven distributed BLM DAQ streams. Using a Python based DAQ simulation with injected timing jitter in place of unavailable live beam data, the pipeline achieved an average end to end latency of 0.456 ms (σ = 0.122 ms) across 167,000 test frames, comfortably meeting the timing constraint. Early outliers were attributed to TensorRT warm-up rather than steady state limitations, suggesting GPU based inference is a viable alternative to the existing FPGA implementation.

Yu, Kellen [Fermilab; Cornell U.]↗

KPiX, An Array of Self Triggered Charge Sensitive Cells Generating Digital Time and Amplitude Information

The Silicon Detector proposed for the International Linear Collider (ILC) requires electronic read-out that can be tightly coupled to the silicon detectors envisioned for the tracker and the electromagnetic calorimeter. The KPiX is a 1024-channel read-out chip that bump-bonds to the detector and communicates through a few digital signals, power, and detector bias. The KPiX front-end is a low-noise dual-range charge-amplifier with a dynamic range of 17 bit, achieved by autonomous switching of the feedback capacitor. The device takes advantage of the ILC duty cycle of 1 ms trains at 5 Hz rate by lowering the supply current after the data acquisition cycle for an average power consumption of <20 {micro}W/channel. During the 1 ms train, up to four events exceeding a programmable threshold can be stored, the amplitude as a voltage on a capacitor for subsequent digitization, the event time in digital format. The chip can be configured for other than ILC applications.

43 PARTICLE ACCELERATORS↗

Problems encountered in fluctuating flame temperature measurements by thermocouple.

Some thermocouple experiments were carried out in order to obtain sensitivity of thermocouple readings to fluctuations in flames and to determine if the average thermocouple reading was representative of the local volume temperature for fluctuating flames. The thermocouples considered were an exposed junction thermocouple and a fully sheathed thermocouple with comparable time constants. Either the voltage signal or indicated temperature for each test was recorded at sampling rates between 300-4,096 Hz. The trace was then plotted with respect to time or sample number so that time variation in voltage or temperature could be visualized and the average indicated temperature could be determined. For experiments where high sampling rates were used, the signal was analyzed using Fast Fourier Transforms (FFT) to determine the frequencies present in the thermocouple signal. This provided a basic observable as to whether or not the probe was able to follow flame oscillations. To enhance oscillations, for some experiments, the flame was forced. An analysis based on thermocouple time constant, coupled with the transfer function for a sinusoidal input was tested against the experimental results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High resolution BPMS with integrated gain correction system

High resolution beam position monitors (BPM) are an essential tool to achieve and reproduce a low vertical beam emittance at the KEK Accelerator Test Facility (ATF) damping ring. The ATF damping ring (DR) BPMs are currently upgraded with new high resolution read-out electronics. Based on analog and digital down-conversion techniques, the upgrade includes an automatic gain calibration system to correct for slow drift effects and ensure high reproducible beam position readings. The concept and its technical realization, as well as preliminary results of beam studies are presented.

43 PARTICLE ACCELERATORS↗

Metagenomic Sequencing of an In Vitro-Simulated Microbial Community

Background: Microbial life dominates the earth, but many species are difficult or even impossible to study under laboratory conditions. Sequencing DNA directly from the environment, a technique commonly referred to as metagenomics, is an important tool for cataloging microbial life. This culture-independent approach involves collecting samples that include microbes in them, extracting DNA from the samples, and sequencing the DNA. A sample may contain many different microorganisms, macroorganisms, and even free-floating environmental DNA. A fundamental challenge in metagenomics has been estimating the abundance of organisms in a sample based on the frequency with which the organism's DNA was observed in reads generated via DNA sequencing. Methodology/Principal Findings: We created mixtures of ten microbial species for which genome sequences are known. Each mixture contained an equal number of cells of each species. We then extracted DNA from the mixtures, sequenced the DNA, and measured the frequency with which genomic regions from each organism was observed in the sequenced DNA. We found that the observed frequency of reads mapping to each organism did not reflect the equal numbers of cells that were known to be included in each mixture. The relative organism abundances varied significantly depending on the DNA extraction and sequencing protocol utilized. Conclusions/Significance: We describe a new data resource for measuring the accuracy of metagenomic binning methods, created by in vitro-simulation of a metagenomic community. Our in vitro simulation can be used to complement previous in silico benchmark studies. In constructing a synthetic community and sequencing its metagenome, we encountered several sources of observation bias that likely affect most metagenomic experiments to date and present challenges for comparative metagenomic studies. DNA preparation methods have a particularly profound effect in our study, implying that samples prepared with different protocols are not suitable for comparative metagenomics.

99 GENERAL AND MISCELLANEOUS↗

Space charge dosimeters for extremely low power measurements of radiation in shipping containers

Methods and apparatus are described for space charge dosimeters for extremely low power measurements of radiation in shipping containers. A method includes insitu polling a suite of passive integrating ionizing radiation sensors including reading-out dosimetric data from a first passive integrating ionizing radiation sensor and a second passive integrating ionizing radiation sensor, where the first passive integrating ionizing radiation sensor and the second passive integrating ionizing radiation sensor remain situated where the dosimetric data was integrated while reading-out. Another method includes arranging a plurality of ionizing radiation sensors in a spatially dispersed array; determining a relative position of each of the plurality of ionizing radiation sensors to define a volume of interest; collecting ionizing radiation data from at least a subset of the plurality of ionizing radiation sensors; and triggering an alarm condition when a dose level of an ionizing radiation source is calculated to exceed a threshold.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identifying messaging completion in a parallel computer by checking for change in message received and transmitted count at each node

Methods, parallel computers, and products are provided for identifying messaging completion on a parallel computer. The parallel computer includes a plurality of compute nodes, the compute nodes coupled for data communications by at least two independent data communications networks including a binary tree data communications network optimal for collective operations that organizes the nodes as a tree and a torus data communications network optimal for point to point operations that organizes the nodes as a torus. Embodiments include reading all counters at each node of the torus data communications network; calculating at each node a current node value in dependence upon the values read from the counters at each node; and determining for all nodes whether the current node value for each node is the same as a previously calculated node value for each node. If the current node is the same as the previously calculated node value for all nodes of the torus data communications network, embodiments include determining that messaging is complete and if the current node is not the same as the previously calculated node value for all nodes of the torus data communications network, embodiments include determining that messaging is currently incomplete.

97 MATHEMATICS AND COMPUTING↗