Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Randomization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Nonvolatile Electrochemical Random‐Access Memory under Short Circuit

Abstract Electrochemical random‐access memory (ECRAM) is a recently developed and highly promising analog resistive memory element for in‐memory computing. One longstanding challenge of ECRAM is attaining retention time beyond a few hours. This short retention has precluded ECRAM from being considered for inference classification in deep neural networks, which is likely the largest opportunity for in‐memory computing. In this work, an ECRAM cell with orders of magnitude longer retention than previously achieved is developed, and which is anticipated to exceed ten years at 85 °C. This study hypothesizes that the origin of this exceptional retention is phase separation, which enables the formation of multiple effectively equilibrium resistance states. This work highlights the promises and opportunities to use phase separation to yield ECRAM cells with exceptionally long, and potentially permanent, retention times.

Kim, Diana S.↗

Application of the random pore model to the carbonation cyclic reaction

Calcium oxide has been proved to be a suitable sorbent for high temperature CO{sub 2} capture processes based on the cyclic carbonation-calcination reaction. It is important to have reaction rate models that are able to describe the behavior of CaO particles with respect to the carbonation reaction. Fresh calcined lime is known to be a reactive solid toward carbonation, but the average sorbent particle in a CaO-based CO{sub 2} capture system experiences many carbonation-calcination cycles and the reactivity changes with the number of cycles. This study applies the random pore model (RPM) to estimate the intrinsic rate parameters for the carbonation reaction and develops a simple model to calculate particle conversion with time as a function of the number of cycles, partial pressure of CO{sub 2}, and temperature. This version of the RPM model integrates knowledge obtained in earlier works on intrinsic carbonation rates, critical product layer thickness, and pore structure evolution in highly cycled particles.

01 COAL, LIGNITE, AND PEAT↗

A modified electrolyte non-random two-liquid model with analytical expression for excess enthalpy: Application to the MEA-H 2 O-CO 2 system

We report accurate thermodynamic properties of electrolyte systems are critical for the design and operation of many chemical processes. A comprehensive description of the thermodynamic framework for multi-electrolyte mixed solvent systems is presented, where the parameter structure of the symmetric electrolyte-Non-Random Two Liquid (e-NRTL) model is reformulated and a thermodynamically consistent and analytically derived formulation for the excess enthalpy is developed from the e-NRTL model. The refined parameter structure of the e-NRTL model avoids numerical singularities of the analytical formulation for the excess enthalpy in the absence of ionic species and extends the derived excess enthalpy formulation to non-electrolyte systems. The thermodynamic framework is demonstrated for the MEA-H 2 O-CO 2 case study using experimental data on thermodynamic quantities for the binary MEA-H 2 O system and the ternary MEA-H 2 O-CO 2 system. The model is implemented in Pyomo and will be available for release in the Institute for the Design of Advanced Energy Systems (IDAES) computational platform.

Monoethanolamine↗

Survival analysis of the CEAwatch multicentre clustered randomized trial

Abstract Background The CEAwatch randomized trial showed that follow-up with intensive carcinoembryonic antigen (CEA) monitoring (CEAwatch protocol) was better than care as usual (CAU) for early postoperative detection of colorectal cancer recurrence. The aim of this study was to calculate overall survival (OS) and disease-specific survival (DSS). Methods For all patients with recurrence, OS and DSS were compared between patients detected by the CEAwatch protocol versus CAU, and by the method of detection of recurrence, using Cox regression models. Results Some 238 patients with recurrence were analysed (7·5 per cent); a total of 108 recurrences were detected by CEA blood test, 64 (55·2 per cent) within the CEAwatch protocol and 44 (41·9 per cent) in the CAU group (P = 0·007). Only 16 recurrences (13·8 per cent) were detected by patient self-report in the CEAwatch group, compared with 33 (31·4 per cent) in the CAU group. There was no significant improvement in either OS or DSS with the CEAwatch protocol compared with CAU : hazard ratio 0·73 (95 per cent 0·46 to 1·17) and 0·78 (0·48 to 1·28) respectively. There were no differences in survival when recurrence was detected by CT versus CEA measurement, but both of these methods yielded better survival outcomes than detection by patient self-report. Conclusion There was no direct survival benefit in favour of the intensive programme, but the CEAwatch protocol led to a higher proportion of recurrences being detected by CEA -based blood test and reduced the number detected by patient self-report. This is important because detection of recurrence by blood test was associated with significantly better survival than patient self-report, indirectly supporting use of the CEAwatch protocol.

Verberne, C. J.↗

Morphological Studies of Solution-Crystallized Thermoplastic Elastomers with Polyethylene Endblocks and a Random-Copolymer Midblock

Styrenic thermoplastic elastomers (TPEs) in the form of triblock copolymers possessing glassy endblocks and a rubbery midblock account for the largest global market of TPEs worldwide, and typically rely on microphase separation of the endblocks and the subsequent formation of rigid microdomains to ensure satisfactory network stabilization. In this work, the morphological characteristics of a relatively new family of crystallizable TPEs that instead consist of polyethylene endblocks and a random-copolymer midblock composed of styrene and (ethylene-co-butylene) moieties are investigated. Copolymer solutions prepared at logarithmic concentrations in a slightly endblock-selective solvent are subjected to crystallization under different time and temperature conditions to ascertain if copolymer self-assembly is directed by endblock crystallization or vice versa. According to transmission electron microscopy, semicrystalline aggregates develop at the lowest solution concentration examined (0.01 wt%), and the size and population of crystals, which dominate the copolymer morphologies, are observed to increase with increasing aging time. Real-space results are correlated with small- and wide-angle X-ray scattering to elucidate the concurrent roles of endblock crystallization and self-assembly of these unique TPEs in solution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Property Prediction of Organic Donor Molecules for Photovoltaic Applications Using Extremely Randomized Trees

Organic solar cells are an inexpensive, flexible alternative to traditional silicon-based solar cells but disadvantaged by low power conversion efficiency due to empirical design and complex manufacturing processes. This process can be accelerated by generating a comprehensive set of potential candidates. However, this would require a laborious trial and error method of modeling all possible polymer configurations. A machine learning model has the potential to accelerate the process of screening potential donor candidates by associating structural features of the compound using molecular fingerprints with their highest occupied molecular orbital energies. In this paper, extremely randomized tree learning models are employed for the prediction of HOMO values for donor compounds, and a web application is developed. Finally, the proposed models outperform neural networks trained on molecular fingerprints as well as SMILES, as well as other state-of-the-art architectures such as Chemception and Molecular Graph Convolution on two datasets of varying sizes.

42 ENGINEERING↗

Crystallization Behavior of Isotactic Propylene-1-Hexene Random Copolymer Investigated by Time-Resolved SAXS/WAXD Techniques

The crystallization behavior of isotactic propylene-1-hexene (PH) random copolymer having 5.7% mole fraction of hexene content was investigated using simultaneous time-resolved small-angle X-ray scattering (SAXS) and wide-angle X-ray diffraction (WAXD) techniques. For this copolymer, the hexene component cannot be incorporated into the unit cell structure of isotactic polypropylene (iPP). Only {alpha}-phase crystal form of iPP was observed when samples were melt crystallized at temperatures of 40 C, 60 C, 80 C, and 100 C. Comprehensive analysis of SAXS and WAXD profiles indicated that the crystalline morphology is correlated with crystallization temperature. At high temperatures (e.g., 100 C) the dominant morphology is the lamellar structure; while at low temperatures (e.g., 40 C) only highly disordered small crystal blocks can be formed. These morphologies are kinetically controlled. Under a small degree of supercooling (the corresponding iPP crystallization rate is slow), a segmental segregation between iPP and hexene components probably takes place, leading to the formation of iPP lamellar crystals with a higher degree of order. In contrast, under a large degree of supercooling (the corresponding iPP crystallization rate is fast), defective small crystal blocks are favored due to the large thermodynamic driving force and low chain mobility.

36 MATERIALS SCIENCE↗

Bayesian Calibration of Stochastic Agent Based Model via Random Forest

Agent-based models (ABM) provide an excellent framework for modeling outbreaks and interventions in epidemiology by explicitly accounting for diverse individual interactions and environments. However, these models are usually stochastic and highly parametrized, requiring precise calibration for predictive performance. When considering realistic numbers of agents and properly accounting for stochasticity, this high-dimensional calibration can be computationally prohibitive. This paper presents a random forest-based surrogate modeling technique to accelerate the evaluation of ABMs and demonstrates its use to calibrate an epidemiological ABM named CityCOVID via Markov chain Monte Carlo (MCMC). The technique is first outlined in the context of CityCOVID's quantities of interest, namely hospitalizations and deaths, by exploring dimensionality reduction via temporal decomposition with principal component analysis (PCA) and via sensitivity analysis. The calibration problem is then presented, and samples are generated to best match COVID-19 hospitalization and death numbers in Chicago from March to June in 2020. Further, these results are compared with previous approximate Bayesian calibration (IMABC) results, and their predictive performance is analyzed, showing improved performance with a reduction in computation.

60 APPLIED LIFE SCIENCES↗

Calabi-Yau CFTs and random matrices

Using numerical methods for finding Ricci-flat metrics, we explore the spectrum of local operators in two-dimensional conformal field theories defined by sigma models on Calabi-Yau targets at large volume. Focusing on the examples of K3 and the quintic, we show that the spectrum, averaged over a region in complex structure moduli space, possesses the same statistical properties as the Gaussian orthogonal ensemble of random matrix theory.

superstring vacua↗

Extended JT supergravity and random matrix models: The power of the string equation

A number of supersymmetric Jackiw-Teitelboim (JT) gravity theories are known to be described (in the Euclidean path integral formulation) by double-scaled random matrix models. Such matrix models can be characterized using a certain “string equation”. It was shown recently that in extended supergravity, when the number of BPS states scales as e$^{S_0}$, where $S_0$ is the extremal entropy, a special ansatz for the leading order solution of the string equation yields the supergravity spectrum. Somewhat miraculously, the construction showed that the functional form of the non-BPS (continuum) sector predicts the precise form of the BPS sector, showing the robustness of the supergravity/matrix-model correspondence. In this paper, we refine the analysis and show that the string equation, combined with some simple requirements on solutions, are powerful tools for constraining the spectrum of extended JT supergravity theories. We re-explore the cases of $\mathcal{N} = 2$ and (small) $\mathcal{N} = 4$ JT supergravity, and then explore the new cases of spectra from $\mathcal{N} = 3$ and $\mathcal{N} = 4$ large JT supergravity (recently derived by Heydeman, Shi, and Turiaci) showing that our approach also works naturally for (nearly) all the models. Based on this success, we conjecture that these new supergravity models also have matrix model descriptions.

Extended Supersymmetry↗

A random unitary circuit model for black hole evaporation

Inspired by the Hayden-Preskill protocol for black hole evaporation, we consider the dynamics of a quantum many-body qudit system coupled to an external environment, where the time evolution is driven by the continuous limit of certain 2-local random unitary circuits. We study both cases where the unitaries are chosen with and without a conserved U(1) charge and focus on two aspects of the dynamics. First, we study analytically and numerically the growth of the entanglement entropy of the system, showing that two different time scales appear: one is intrinsic to the internal dynamics (the scrambling time), while the other depends on the system-environment coupling. In the presence of a U(1) conserved charge, we show that the entanglement follows a Page-like behavior in time: it begins to decrease in the middle stage of the “evaporation”, and decreases monotonically afterwards. Second, we study the time needed to retrieve information initially injected in the system from measurements on the environment qudits. Based on explicit numerical computations, we characterize such time both when the retriever has control over the initial configuration or not, showing that different scales appear in the two cases.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reflected entropy in random tensor networks. Part III. Triway cuts

For general random tensor network states at large bond dimension, we prove that the integer Rényi reflected entropies (away from phase transitions) are determined by minimal triway cuts through the network. This generalizes the minimal cut description of bipartite entanglement for these states. A natural extrapolation away from integer Rényi parameters, suggested by the triway cut problem, implies the holographic conjecture S R = 2EW, where S R is the reflected entropy and EW is the entanglement wedge cross-section. Minimal triway cuts can be formulated as integer programs which cannot be relaxed to find a dual maximal flow/bit-thread description. This sheds light on the gap between the existence of tripartite entanglement in holographic states and the bipartite entanglement structure motivated by bit-threads. In particular, we prove that the Markov gap that measures tripartite entanglement is lower bounded by the integrality gap of the integer program that computes the triway cut.

AdS-CFT correspondence↗

Experiments on the Richtmyer–Meshkov instability with an imposed, random initial perturbation

A vertical shock tube is used to perform experiments on the Richtmyer–Meshkov instability with a three-dimensional random initial perturbation. A membraneless flat interface is formed by opposed gas flows in which the light and heavy gases enter the shock tube from the top and from the bottom of the shock tube driven section. An air/SF6 gas combination is used and a Mach number M = 1.2 incident shock wave impulsively accelerates the interface. Initial perturbations on the interface are created by vertically oscillating the gas column within the shock tube to produce Faraday waves on the interface resulting in a short wavelength, three-dimensional perturbation. Planar Mie scattering is used to visualize the flow in which light from a laser sheet is scattered by smoke seeded in the air, and image sequences are captured using three high-speed video cameras. Measurements of the integral penetration depth prior to reshock show two growth behaviors, both having power law growth with growth exponents in the range found in previous experiments and simulations. Following reshock, all experiments showvery consistent linear growth with a growth rate in good agreement with those found in previous studies.

42 ENGINEERING↗

3-Methyl-1-butanol production in Escherichia coli : random mutagenesis and two-phase fermentation

Interest in producing biofuels from renewable sources has escalated due to energy and environmental concerns. Recently, the production of higher chain alcohols from 2-keto acid pathways has shown significant progress. In this paper, we demonstrate a mutagenesis approach in developing a strain of Escherichia coli for the production of 3-methyl-1-butanol by leveraging selective pressure toward L-leucine biosynthesis and screening for increased alcohol production. Random mutagenesis and selection with 4-aza-D,L-leucine, a structural analogue to L-leucine, resulted in the development of a new strain of E. coli able to produce 4.4 g/L of 3-methyl-1-butanol. Investigation of the host’s sensitivity to 3-methyl-1-butanol directed development of a two-phase fermentation process in which titers reached 9.5 g/L of 3-methyl-1-butanol with a yield of 0.11 g/g glucose after 60 h.

09 BIOMASS FUELS↗

A Comparison of Four- Versus Three-Pass Transjugular Biopsy Using a 19-G Tru-Cut Needle and a Randomized Study Using a Cassette to Prevent Biopsy Fragmentation

Recently, it has been shown that transjugular liver biopsy (TJLB) with three passes gives comparable specimens to percutaneous liver biopsy (PLB). The aim of this study was to evaluate the adequacy of TJLB using four passes in a consecutive series of patients, and whether using a supportive cassette can prevent fragmentation. One hundred consecutive TJLBs in 92 patients (48 transplanted), always using four passes (19-G Tru-Cut), were compared to three-pass TJLBs. The four-pass TJLB specimens were randomized at a 1:1 ratio of liver cores placed in a cassette versus not. The four-pass TJLBs, compared to three-pass TJLBs, resulted in better specimens for length ({>=}25 mm: 50% vs. 35%; p = 0.026) and number of complete portal tracts (CPTs) ({>=}11: 40% vs. 26%; p = 0.027), without a higher complication rate. The four-pass TJLB with {>=}11 CPTs had a median length of 27 mm, and 57% of them longer than 28 mm contained {>=}11 CPTs. Putting the liver biopsy cores into a cassette did not improve the fragmentation rate or adequacy of the specimen (length and number of CPTs) of TJLB. We conclude that at least four passes with TJLB should be performed when liver specimens are needed for grading and staging. Using a supportive cassette did not reduce fragmentation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Embolization of the Gastroduodenal Artery Before Selective Internal Radiotherapy: A Prospectively Randomized Trial Comparing Platinum-Fibered Microcoils with the Amplatzer Vascular Plug II

The Amplatzer Vascular Plug II (AVP II) is a novel device for transcatheter vessel occlusion, for which only limited comparative data exist. Embolotherapy of the gastroduodenal artery (GDA) is essential before internal radiotherapy (SIRT) in order to prevent radiation-induced peptic ulcerations due to migration of yttrium-90 microspheres. The purpose of this study was to compare the vascular anatomical limitations, procedure time, effectiveness, and safety of embolization of the GDA with coils versus the AVP II. Fifty patients stratified for SIRT were prospectively randomized for embolization of the GDA with either coils or the AVP II. The angle between the aorta and the celiac trunk, diameter of the GDA, fluoroscopy time and total time for embolization, number of embolization devices, complications, and durability of vessel occlusion at follow-up angiography for SIRT were recorded. A t-test was used for statistical analysis. Embolizations with either coils or the AVP II were technically feasible in all but two patients scheduled for embolization of the GDA with the AVP II. In both cases the plug could not be positioned due to the small celiac trunk outlet angles of 17{sup o} and 21{sup o}. The mean diameter of the GDA was 3.7 mm (range, 2.2-4.8 mm) for both groups. The procedures differed significantly in fluoroscopy time (7.8 min for coils vs. 2.6 min for the AVP II; P < 0.001) and embolization time (23.1 min for coils vs. 8.8 min for the AVP II; P < 0.001). A mean of 6.0 {+-} 3.2 coils were used for GDA embolization, while no more than one AVP II was needed for successful vessel occlusion (P < 0.001). One coil migration occurred during coil embolization, whereas no procedural complication was encountered with the use of the AVP II. Vessel reperfusion was noted in only one patient, in whom coil embolization was performed. In conclusion, embolization of the GDA with the AVP II is safe, easy, rapid, and highly effective; only an extremely sharp-angled celiac trunk outlet represented an anatomical limitation for device deployment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Embolization of the Gastroduodenal Artery Before Selective Internal Radiotherapy: A Prospectively Randomized Trial Comparing Standard Pushable Coils with Fibered Interlock Detachable Coils

The purpose of this study was compare embolization of the gastroduodenal artery (GDA) using standard pushable coils with the Interlock detachable coil (IDC), a novel fibered mechanically detachable long microcoil, in patients scheduled for selective internal radiotherapy (SIRT). Fifty patients (31 male and 19 female; median age 66.6 {+-} 8.1 years) were prospectively randomized for embolization using either standard coils or IDCs. Procedure time, radiation dose, number of embolization devices, complications, and durability of vessel occlusion at follow-up angiography were recorded. The procedures differed significantly in time (14:32 {+-} 5:56 min for standard coils vs. 2:13 {+-} 1:04 min for IDCs; p < 0.001); radiation dose for coil deployment (2479 {+-} 1237 cGycm Superscript-Two for standard coils vs. 275 {+-} 268 cGycm Superscript-Two for IDCs; p < 0.001); and vessel occlusion (17:18 {+-} 6:39 min for standard coils vs. 11:19 {+-} 7:54 min for IDCs; p = 0.002). A mean of 6.2 {+-} 1.8 coils (n = 27) were used in the standard coil group, and 1.3 {+-} 0.9 coils (p < 0.0001) were used in the IDC group (n = 23) because additional pushable coils were required to achieve GDA occlusion in 4 patients. In 2 patients, the IDC could not be deployed through a Soft-VU catheter. One standard coil dislodged in the hepatic artery and was retrieved. Vessel reperfusion was noted in only 1 patient in the standard coil group. Controlled embolization of the GDA with fibered IDCs was achieved more rapidly than with pushable coils. However, vessel occlusion may not be obtained using a single device only, and the use of sharply angled guiding catheters hampered coil pushability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Palliation of Pancreatic Head Cancer: Randomized Comparison of ePTFE/FEP-Covered Versus Uncovered Nitinol Biliary Stents

The purpose of this study was to compare the clinical effectiveness of expanded polytetrafluoroethylene/fluorinated-ethylene-propylene (ePTFE/FEP)-covered stents with that of uncovered nitinol stents for the palliation of malignant jaundice caused by inoperable pancreatic head cancer. Eighty patients were enrolled in a prospective randomized study. Bare nitinol stents were used in half of the patients, and ePTFE/FEP-covered stents were used in the remaining patients. Patency, survival, complications, and mean cost were calculated in both groups. Mean patency was 166.0 {+-} 13.11 days for the bare-stent group and 234.0 {+-} 20.87 days for the covered-stent group (p = 0.007). Primary patency rates at 3, 6, and 12 months were 77.5, 69.8, and 69.8% for the bare-stent group and 97.5, 92.2, and 87.6% for the covered-stent group, respectively. Mean secondary patency was 123.7 {+-} 22.5 days for the bare-stent group and 130.3 {+-} 21.4 days for the covered-stent group. Tumour ingrowth occurred exclusively in the bare-stent group in 27.5% of cases (p = 0.002). Median survival was 203.2 {+-} 11.8 days for the bare-stent group and 247.0 {+-} 20 days for the covered-stent group (p = 0.06). Complications and mean cost were similar in both groups. Regarding primary patency and ingrowth rate, ePTFE/FEP-covered stents have shown to be significantly superior to bare nitinol stents for the palliation of malignant jaundice caused by inoperable pancreatic head cancer and pose comparable cost and complications. Use of a covered stent does not significantly influence overall survival rate; nevertheless, the covered endoprosthesis seems to offer result in fewer reinterventions and better quality of patient life.

62 RADIOLOGY AND NUCLEAR MEDICINE↗