Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Precise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Precision Measurements of Electron-Proton Elastic Scattering Cross Sections at Large Q2

The electromagnetic form factors are fundamental quantities characterizing the internal structure of the nucleon. Their measurements have provided significant insight into the spatial distribution and interaction of quarks inside the proton. The knowledge of high Q2 form factors proves essential in understanding the properties of quantum chromodynamics in the transition region from non-perturbative to perturbative behavior. It also provides important links to generalized parton distributions, which describe the three-dimensional structure of hadrons at the parton level. In view of the significant theoretical research activities in this field, high quality experimental data are crucial for providing stringent tests and benchmarks to guide and test different models. The form factors can be accessed in experiments by measuring elastic scattering of electrons off a hydrogen target. Experiment E12-07-108, which took place at the Thomas Jefferson National Accelerator Facility, conducted precise measurements of the unpolarized e-p elastic scattering cross section over a Q2 range of 0.6-16.5 GeV2 . This thesis presents the results for 7 kinematic settings with total uncertainties that are 1.5 times smaller than those of the existing data at large Q2 . The proton magnetic form factors were extracted using a parameterization of the form factor ratio obtained from recent polarized e-p scattering experiments. Comparisons to existing global and phenomenological fits are presented.

Ou, Longwu↗

The ETROC Project: Precision Timing ASIC Development for LGAD-based CMS Endcap Timing Layer (ETL) Upgrade

The ETROC (Endcap Timing Readout Chip) is being developed for the LGAD-based CMS Endcap Timing Layer (ETL) at HL-LHC. The ETL on each side of the interaction region will be instrumented with a two-disk system of MIP-sensitive LGAD silicon devices to be read out by ETROCs for precision timing measurement with down to 30 ps timing resolution. The ETROC is designed to handle a 16 x 16 pixel cell matrix, with each pixel cell being 1.3 mm x 1.3 mm to match the LGAD sensor pixel size. Approximately 15% of the sensors near the highest eta region will experience hadron fluence above 1e15 neq/cm² towards end of operation of HL-LHC, resulting in small signal amplitude with LGAD gain reduced to around 10. For this reason, the front-end design for preamplifier and discriminator has been specifically optimized for the reduced LGAD signals, with enough flexibilities to meet the ETL specific needs for time resolution, power budget and radiation profile.

97 MATHEMATICS AND COMPUTING↗

Precision Measurement of the Proton Magnetic Form Factor at High Q2

Elastic electromagnetic form factors characterize the distribution of electric charge and magnetization current inside the nucleon and reflect the internal structure determined by Quantum Chromodynamics. Existing data on the proton magnetic form factor at high Q2 (the 4-momentum transfer squared) have large statistical and systematic uncertainties. The GMp experiment E12-07-108 was one of the first set of experiments to run in Hall A at Jefferson Lab after the 12 GeV upgrade with the goal of this experiment to precisely measure the electron-proton elastic cross section for Q2 up to 17 GeV2 with an accuracy of better than 2% - several times better than existing data in this Q2 range. This will allow further tests of form factor scaling predicted by pQCD and, additionally, will be an important benchmark for many other experiments where elastic electron-proton scattering is used for normalization. Since, GMp data were taken at lower ?(virtual photon polarization) than SLAC data, the measured cross sections recieve a smaller contribution from the electric form factor. This dissertation analyzed the GMp experiment data for five different kinematic settings determining the form factor with total uncertainties nearly two times smaller than the existing data at these Q2. This dissertation also presents the results of all Fall 2016 and Spring 2016 GMp experiment data. The proton magnetic form factors were extracted using both the Rosenbluth separation method and a parameterization of the form factor ratio (?pGpE=GpM) obtained from a fit to the existing cross section data. At the end of this thesis, the extracted GMp form factor data is compared to the existing data. The results for ?pGpE=GpM from Rosenbluth separations are found to be consistent with previous extractions, but with significantly reduced uncertainties, further highlighting the discrepancy with the polarization transfer technique. This data set can provide significant additional constraints on contributions from two-photon exchange.

Narayan Gautam, Thir↗

Precision γ-ray branching ratio measurements for long-lived fission products of importance to nuclear-security applications (TAMU Annual Report 2020)

Continuing with our effort of precisely measuring the branching ratios for long-lived fission products we have collected and measured two radiopure ¹⁵⁶Eu samples. The samples were collected on thin (40 μg/cm²) carbon-foil backings using a low-energy mass-separated beam of A = 156 fission products from CARIBU at Argonne National Laboratory. During collection, a HPGe detector was used to continuously monitor the implantation rate by detecting the characteristic γ rays emitted following the β decay of the shorter-lived fission products. The first sample had measured activity of 375 Bq while the second one had an activity of 700 Bq. The implanted samples were then shipped to Texas A&M University for measurement of the subsequent decay.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Trinity High Explosive Implosion System: The Foundation for Precision Explosive Applications

This article is set during the 1944 and 1945 final push to complete Project Y—the Manhattan Project at Los Alamos—and focuses primarily on overcoming the challenge of creating and demonstrating a successful convergent explosive implosion to turn a subcritical quantity of plutonium into a critical mass. The critical mass would then efficiently yield kilotons of trinitrotoluene (TNT)-equivalent energy in about a microsecond, demonstrating the implosion atomic bomb concept. This work culminated in the Trinity atomic test near Alamogordo on July 16, 1945. This implosion effect demarcated the approach to explosive science and technology the Laboratory has followed ever since, including development of high-explosive synthesis and formulation, small and large test and diagnostic facilities, shock dynamics theory, high-explosive system design engineering, and three-dimensional implosion modeling and simulation using some of the fastest computers in the world. This work also ushered in a period of broader application of precision high explosives in conventional munitions, demolition, mining and oil exploration, and space travel.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Institutional Computing: Annual Progress Report, Precision early universe simulations to constrain nuclear reactions and beyond standard model physics

The current one-year allocation (w20 qburst) is the first year in a two year allocation of the same name. The project has supported two publications in peer-review journals, another manuscript in preparation for publication, a white paper for the Astro2020 Decadal Survey, and a number of talks (see below). Code development continues on implementing a neutrino quantum kinetic equation solver into BURST, now called QBURST. While implementing coherent and forward-scattering processes into the dynamical neutrino evolution equations, multiple numerical issues have appeared. We have remedied a number of these issues through extensive debugging and testing, which include streamlining interpolation and implementing new ODE integration techniques. Further testing is required to solve the problem at a precision of better than one part in 10 6 . We expect that we will understand the numerical difficulties and implement solutions by end of year 2021.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Variable Precision Computing (VPC) (Final Report)

The overall goal of the Variable Precision Computing project is exploring and identifying ways to reduce internodal communication cost in production physics simulation experiments running on a distributed-memory systems by compressing data, either in a lossy or lossless way, thus resulting in a significant computational performance increase. Among the several approaches proposed, the one discussed here has been proposed, designed and implemented by me. It concerns the application of information theory-derived metrics to classical molecular dynamics and computational fluid dynamics simulation experiments.

97 MATHEMATICS AND COMPUTING↗

Mixed Precision Numerical Linear Algebra (Final Report)

The objective of this subcontract was to identify opportunities for the use of mixed precision within iterative solvers and to explore these opportunities both theoretically and experimentally. All quarterly milestones were achieved. We summarize the achievements each quarter in sections below.

97 MATHEMATICS AND COMPUTING↗

Precision Electroweak and QCD Studies with Polarized Electrons (Final Technical Report)

In this final technical report, we report on the main products from the scope of the work of the award, in particular the Ph.D. dissertations that summarize the work done by the three graduate students who completed their requirements and defenses during calendar 2021, after completing data analyses on the PREX-II and CREX experiments which made precision measurements of neutron RMS radii of 208 Pb and 48 Ca nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Workshop on Ultra-Precision Control for Ultra-Efficient Devices (Workshop Report)

On April 21–23, the U.S. Department of Energy’s (DOE’s) Advanced Manufacturing Office (AMO) within the office of Energy Efficiency and Renewable Energy (EERE) held the second in a series of workshops on different topics related to semiconductor research and development (R&D) to increase energy efficiency. This workshop focused on ultra-energy-efficient devices and the ultra-precision manufacturing (UPM) processes and next-generation control and metrology technologies needed to manufacture these devices. In addition to the industry needs and RDD&D opportunities, AMO’s new goal on greenhouse gas (GHG) reduction was addressed. The output of this workshop will inform AMO’s future R&D portfolio investments; provide perspectives on trends, drivers, and challenges for ultra-energy-efficient devices and enabling technologies; and help the stakeholder community understand the opportunities on the horizon.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy-Energy Correlators for Precision QCD

In this contribution to the Proceedings of the US Community Study on the Future of Particle Physics (Snowmass 2021) we review recent progress in the evaluation and application of the Energy-Energy Correlator (EEC) event shape observable in $e^+e^⁻$ annihilation, hadronic collisions, and deep inelastic scattering. The importance of EEC as a precision probe of the perturbative and non perturbative aspects of QCD dynamics is emphasized. It can be used to extract the strong coupling constant and to constrain TMD distribution functions. Closely related energy-correlation shape variables have also been used to tag boosted objects produced in high energy collisions. The opportunities to study EEC at the future Electron-Ion Collider are also highlighted.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High Precision Penning Trap Measurements of beta-decay Q-values for Neutrino Physics

The 2015 Nobel Prize in physics was awarded to Takaaki Kajita and Arthur B. McDonald “for the discovery of neutrino oscillations, which shows that neutrinos have mass”. This fact has wide reaching implications for the standard model of particle physics, nuclear physics, and cosmology. However, important fundamental questions remain: What is the absolute neutrino mass scale? Is the neutrino a Majorana or a Dirac particle? A number of large-scale experiments are underway or are being developed to attempt to answer these questions. Two classes of experiments are direct neutrino mass determination experiments, and searches for neutrinoless double betadecay. This work aimed to aid these experiments via high-precision Q value determinations for the relevant isotopes using Penning trap mass spectrometry (PTMS).

42 ENGINEERING↗

Mixed Precision Numerical Linear Algebra (Final Report)

The objective of this subcontract was to identify opportunities for the use of mixed precision within iterative solvers and to explore these opportunities both theoretically and experimentally. All quarterly milestones were achieved. We summarize the achievements each quarter in this report.

97 MATHEMATICS AND COMPUTING↗

Specification of EBR-II Gamma Scan Data from the Precision Gamma Scanner

The gamma scan data stored in the FIPD was originally measured using the Precision Gamma Scanner (PGS) at the Hot Fuel Examination Facility (HFEF) at Idaho National Laboratory (INL). This system was originally manufactured in 1971 (when the facilities, now at INL, were operated by Argonne National Laboratory) and was upgraded on several occasions. It consists of a germanium gamma ray detector (the exact nature of which changed over time as technology improved), a variable-slit collimator that blocks the view of gamma emissions from all but the selected area of the target, and a computer-controlled system for translating a sample past the slit and logging the data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision Measurement of the Eta Radiative Decay Width via the Primakoff Effect with GlueX

The GlueX detector in the experimental Hall-D at Jefferson Lab provides a unique capability to perform a measurement of the eta to gamma gamma decay width via the Primakoff effect with the precision significantly better than all existing collider and Primakoff results. The experiment will measure differential cross sections of eta mesons at forward angles on a liquid hydrogen and helium targets using a beam of tagged photons, which will be used for the extraction of the decay width. The measurement is essential for the determination of the fundamental properties such as the ratios of the light quark masses and the eta eta-prime mixing angle, and will provide an important test of chiral symmetry breaking in QCD. The experimental results will also allow to significantly reduce uncertainties on partial widths of all other eta decays. We will give an overview the PrimEx-D physics program and experimental setup.

Somov, Alexander↗