Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Positioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

SU-E-J-220: Assessment of MRI Geometric Distortion in Head and Neck Cancer Patients Scanned in Immobilized Radiation Treatment Position

Purpose: Uncertainties about geometric distortion have somewhat hindered MRI simulation in radiation therapy. Most of the geometric distortion studies were performed with phantom measurements but another major aspect of MR distortion is patient related. We studied the geometric distortion in patient images by comparing their MRI scans with the corresponding CT, using CT as the non-distorted gold standard. Methods: Ten H&N cancer patients were imaged with MRI as part of a prospective IRB approved study. All patients had their treatment planning CT done on the same day or within one week of the MRI. MR Images were acquired with a T2 SE sequence (1×1×2.5mm voxel size) in the same immobilization position as in the CT scans. MRI to CT rigid registration was then done and geometric distortion comparison was done by measuring the corresponding anatomical landmarks on both the MRI and the CT images by two observers. Several skin to skin (9 landmarks), bone to bone (8 landmarks), and soft tissue (3 landmarks) were measured at specific levels in horizontal and vertical planes of both scans. Results: The mean distortion for all landmark measurements in all scans was 1.8±1.9mm. For each patient 11 measurements were done in the horizontal plane while 9 were done in the vertical plane. The measured geometric distortion were significantly lower in the horizontal axis compared to the vertical axis (1.3±0.16 mm vs 2.2±0.19 mm, respectively, P=0.003*). The magnitude of distortion was lower in the bone to bone landmarks compared to the combined soft tissue and skin to skin landmarks (1.2±0.19 mm vs 2.3±0.17 mm, P=0.0006*). The mean distortion measured by observer one was not significantly different compared toobserver 2 (2.3 vs 2.4 mm, P=0.4). Conclusion: MRI geometric distortions were quantified in H&N patients with mean error of less than 2 mm. JW received a corporate sponsored research grant from Elekta.

60 APPLIED LIFE SCIENCES↗

Automated detection of pulmonary nodules in PET/CT images: Ensemble false-positive reduction using a convolutional neural network technique

Purpose: Automated detection of solitary pulmonary nodules using positron emission tomography (PET) and computed tomography (CT) images shows good sensitivity; however, it is difficult to detect nodules in contact with normal organs, and additional efforts are needed so that the number of false positives (FPs) can be further reduced. In this paper, the authors propose an improved FP-reduction method for the detection of pulmonary nodules in PET/CT images by means of convolutional neural networks (CNNs). Methods: The overall scheme detects pulmonary nodules using both CT and PET images. In the CT images, a massive region is first detected using an active contour filter, which is a type of contrast enhancement filter that has a deformable kernel shape. Subsequently, high-uptake regions detected by the PET images are merged with the regions detected by the CT images. FP candidates are eliminated using an ensemble method; it consists of two feature extractions, one by shape/metabolic feature analysis and the other by a CNN, followed by a two-step classifier, one step being rule based and the other being based on support vector machines. Results: The authors evaluated the detection performance using 104 PET/CT images collected by a cancer-screening program. The sensitivity in detecting candidates at an initial stage was 97.2%, with 72.8 FPs/case. After performing the proposed FP-reduction method, the sensitivity of detection was 90.1%, with 4.9 FPs/case; the proposed method eliminated approximately half the FPs existing in the previous study. Conclusions: An improved FP-reduction scheme using CNN technique has been developed for the detection of pulmonary nodules in PET/CT images. The authors’ ensemble FP-reduction method eliminated 93% of the FPs; their proposed method using CNN technique eliminates approximately half the FPs existing in the previous study. These results indicate that their method may be useful in the computer-aided detection of pulmonary nodules using PET/CT images.

60 APPLIED LIFE SCIENCES↗

4D-CT scans reveal reduced magnitude of respiratory liver motion achieved by different abdominal compression plate positions in patients with intrahepatic tumors undergoing helical tomotherapy

Purpose: While abdominal compression (AC) can be used to reduce respiratory liver motion in patients receiving helical tomotherapy for hepatocellular carcinoma, the nature and extent of this effect is not well described. The purpose of this study was to evaluate the changes in magnitude of three-dimensional liver motion with abdominal compression using four-dimensional (4D) computed tomography (CT) images of several plate positions. Methods: From January 2012 to October 2015, 72 patients with intrahepatic carcinoma and divided into four groups underwent 4D-CT scans to assess respiratory liver motion. Of the 72 patients, 19 underwent abdominal compression of the cephalic area between the subxiphoid and umbilicus (group A), 16 underwent abdominal compression of the caudal region between the subxiphoid area and the umbilicus (group B), 11 patients underwent abdominal compression of the caudal umbilicus (group C), and 26 patients remained free breathing (group D). 4D-CT images were sorted into ten-image series, according to the respiratory phase from the end inspiration to the end expiration, and then transferred to treatment planning software. All liver contours were drawn by a single physician and confirmed by a second physician. Liver relative coordinates were automatically generated to calculate the liver respiratory motion in different axial directions to compile the 10 ten contours into a single composite image. Differences in respiratory liver motion were assessed with a one-way analysis of variance test of significance. Results: The average respiratory liver motion in the Y axial direction was 4.53 ± 1.16, 7.56 ± 1.30, 9.95 ± 2.32, and 9.53 ± 2.62 mm in groups A, B, C, and D, respectively, with a significant change among the four groups (p < 0.001). Abdominal compression was most effective in group A (compression plate on the subxiphoid area), with liver displacement being 2.53 ± 0.93, 4.53 ± 1.16, and 2.14 ± 0.92 mm on the X-, Y-, and Z-axes, respectively. There was no significant difference in respiratory liver motion between group C (displacement: 3.23 ± 1.47, 9.95 ± 2.32, and 2.92 ± 1.10 mm on the X-, Y-, and Z-axes, respectively) and group D (displacement: 3.35 ± 1.55, 9.53 ± 2.62, and 3.35 ± 1.73 mm on the X-, Y-, and Z-axes, respectively). Abdominal compression was least effective in group C (compression on caudal umbilicus), with liver motion in this group similar to that of free-breathing patients (group D). Conclusions: 4D-CT scans revealed significant liver motion control via abdominal compression of the subxiphoid area; however, this control of liver motion was not observed with compression of the caudal umbilicus. The authors, therefore, recommend compression of the subxiphoid area in patients undergoing external radiotherapy for intrahepatic carcinoma.

60 APPLIED LIFE SCIENCES↗

Effect of pulse sequence parameter selection on signal strength in positive-contrast MRI markers for MRI-based prostate postimplant assessment

Purpose: For postimplant dosimetric assessment, computed tomography (CT) is commonly used to identify prostate brachytherapy seeds, at the expense of accurate anatomical contouring. Magnetic resonance imaging (MRI) is superior to CT for anatomical delineation, but identification of the negative-contrast seeds is challenging. Positive-contrast MRI markers were proposed to replace spacers to assist seed localization on MRI images. Visualization of these markers under varying scan parameters was investigated. Methods: To simulate a clinical scenario, a prostate phantom was implanted with 66 markers and 86 seeds, and imaged on a 3.0T MRI scanner using a 3D fast radiofrequency-spoiled gradient recalled echo acquisition with various combinations of scan parameters. Scan parameters, including flip angle, number of excitations, bandwidth, field-of-view, slice thickness, and encoding steps were systematically varied to study their effects on signal, noise, scan time, image resolution, and artifacts. Results: The effects of pulse sequence parameter selection on the marker signal strength and image noise were characterized. The authors also examined the tradeoff between signal-to-noise ratio, scan time, and image artifacts, such as the wraparound artifact, susceptibility artifact, chemical shift artifact, and partial volume averaging artifact. Given reasonable scan time and managable artifacts, the authors recommended scan parameter combinations that can provide robust visualization of the MRI markers. Conclusions: The recommended MRI pulse sequence protocol allows for consistent visualization of the markers to assist seed localization, potentially enabling MRI-only prostate postimplant dosimetry.

60 APPLIED LIFE SCIENCES↗

SU-F-J-47: Inherent Uncertainty in the Positional Shifts Determined by a Volumetric Cone Beam Imaging System

Purpose: To quantify inherent uncertainty associated with a volumetric imaging system in its determination of positional shifts. Methods: The study was performed on an Elekta Axesse™ linac’s XVI cone beam computed tomography (CBCT) system. A CT image data set of a Penta- Guide phantom was used as reference image by placing isocenter at the center of the phantom.The phantom was placed arbitrarily on the couch close to isocenter and CBCT images were obtained. The CBCT dataset was matched with the reference image using XVI software and the shifts were determined in 6-dimensions. Without moving the phantom, this process was repeated 20 times consecutively within 30 minutes on a single day. Mean shifts and their standard deviations in all 6-dimensions were determined for all the 20 instances of imaging. For any given day, the first set of shifts obtained was kept as reference and the deviations of the subsequent 19 sets from the reference set were scored. Mean differences and their standard deviations were determined. In this way, data were obtained for 30 consecutive working days. Results: Tabulating the mean deviations and their standard deviations observed on each day for the 30 measurement days, systematic and random errors in the determination of shifts by XVI software were calculated. The systematic errors were found to be 0.03, 0.04 and 0.03 mm while random errors were 0.05, 0.06 and 0.06 mm in lateral, craniocaudal and anterio-posterior directions respectively. For rotational shifts, the systematic errors were 0.02°, 0.03° and 0.03° and random errors were 0.06°, 0.05° and 0.05° in pitch, roll and yaw directions respectively. Conclusion: The inherent uncertainties in every image guidance system should be assessed and baseline values established at the time of its commissioning. These shall be periodically tested as part of the QA protocol.

60 APPLIED LIFE SCIENCES↗

SU-F-J-55: Feasibility of Supraclavicular Field Treatment by Investigating Variation of Junction Position Between Breast Tangential and Supraclavicular Fields for Deep Inspiration Breath Hold (DIBH) Left Breast Radiation

Purpose: To explore the feasibility of supraclavicular field treatment by investigating the variation of junction position between tangential and supraclavicular fields during left breast radiation using DIBH technique. Methods: Six patients with left breast cancer treated using DIBH technique were included in this study. AlignRT system was used to track patient’s breast surface. During daily treatment, when the patient’s DIBH reached preset AlignRT tolerance of ±3mm for all principle directions (vertical, longitudinal, and lateral), the remaining longitudinal offset was recorded. The average with standard-deviation and the range of daily longitudinal offset for the entire treatment course were calculated for all six patients (93 fractions totally). The ranges of average ± 1σ and 2σ were calculated, and they represent longitudinal field edge error with the confidence level of 68% and 95%. Based on these longitudinal errors, dose at junction between breast tangential and supraclavicular fields with variable gap/overlap sizes was calculated as a percentage of prescription (on a representative patient treatment plan). Results: The average of longitudinal offset for all patients is 0.16±1.32mm, and the range of longitudinal offset is −2.6 to 2.6mm. The range of longitudinal field edge error at 68% confidence level is −1.48 to 1.16mm, and at 95% confidence level is −2.80 to 2.48mm. With a 5mm and 1mm gap, the junction dose could be as low as 37.5% and 84.9% of prescription dose; with a 5mm and 1mm overlap, the junction dose could be as high as 169.3% and 117.6%. Conclusion: We observed longitudinal field edge error at 95% confidence level is about ±2.5mm, and the junction dose could reach 70% hot/cold between different DIBH. However, over the entire course of treatment, the average junction variation for all patients is within 0.2mm. The results from our study shows it is potentially feasible to treat supraclavicular field with breast tangents.

60 APPLIED LIFE SCIENCES↗

SU-F-J-159: Influence of the Elevated Posterior Position by Using the Customized Vacuum-Bag On the Abdominal MR Image Quality: A Quantitative Phantom Study

Purpose: Signal-to-noise ratio(SNR) of MR abdominal imaging in diagnostic radiology is maximized by minimizing the coil-to-patient distance. However, for radiotherapy applications, customized vacuum-bag is needed for abdominal immobilization at the cost of the increasing distance to the posterior spine coil. This sub-optimized coil setting for RT applications may compromise image quality, such as SNR and homogeneity, thus potentially affect tissue delineation. In this study, we quantitatively evaluate the effect of the vertical position change on SNR and image quality change using an ACR MR phantom. Methods: An ACR MR phantom was placed on the flat couch top. Images were acquired using an 18-channel body array coil and spine coil on a dedicated 1.5T MR-simulator. The scan was repeated three times with the ACR phantom elevated up to 7.5cm from the couch top, with a step size of 2.5cm. All images were acquired using standard ACR test sequence protocol of 2D spin-echo T1-weighted(TR/TE=500/200ms) and T2-weighted(TR/TE1/TE2=2000/20/80) sequences. For all scans, pre-scan normalization was turned on, and the distance between the phantom and the anterior 18-channel body array coil was kept constant. SNR was calculated using the slice with a large water-only region of the phantom. Percent intensity uniformity(PIU) and low contrast object detectability(LCD) were assessed by following ACR test guidelines. Results: The decrease in image SNR(from 335.8 to 169.3) and LCD(T1: from 31 to 19 spokes, T2: 26 to 16 spokes) were observed with increasing vertical distance. After elevating the phantom by 2.5cm(approximately the thickness of standard vacuum-bag), SNR change(from 335.8 to 275.5) and LCD(T1: 31 to 26 spokes, T2: 26 to 21 spokes) change were noted. However, similar PIU was obtained for all choices of vertical distance (T1: 94.5%–95.0%, T2: 94.4%–96.8%). Conclusion: After elevating the scan object, reduction in SNR level and contrast detectability but no change in image homogeneity was observed.

60 APPLIED LIFE SCIENCES↗

Mechanism of β2AR regulation by an intracellular positive allosteric modulator

Drugs targeting the orthosteric, primary binding site of G protein–coupled receptors are the most common therapeutics. Allosteric binding sites, elsewhere on the receptors, are less well-defined, and so less exploited clinically. In this paper we report the crystal structure of the prototypic β 2 -adrenergic receptor in complex with an orthosteric agonist and compound-6FA, a positive allosteric modulator of this receptor. It binds on the receptor’s inner surface in a pocket created by intracellular loop 2 and transmembrane segments 3 and 4, stabilizing the loop in an α-helical conformation required to engage the G protein. Structural comparison explains the selectivity of the compound for β 2 - over the β 1 -adrenergic receptor. Diversity in location, mechanism, and selectivity of allosteric ligands provides potential to expand the range of receptor drugs.

60 APPLIED LIFE SCIENCES↗

Band intensities in the circular dichroism and absorption spectra and the states of d ions in absorbing media: I. Octahedrally coordinated positions of d ions

The factors affecting the band intensity in circular dichroism (CD) and absorption spectra (selection rules, point group of structural position, and the electron density of the ground state of octahedrally coordinated d ion in absorbing medium) are considered. The intensities of CD and absorption bands are calculated and compared with the experimental data. It is shown that the differences in the spatial inversion of the electric- and magnetic-dipole moment transformations lead to a more rigorous validity of the symmetry selection rules and increase the resolution of peaks and transparency window of medium absorption in CD spectra (in contrast to absorption ones). Some criteria for estimating the valence and structural states of d ions are formulated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Accurate crystal-structure refinement of Ca{sub 3}Ga{sub 2}Ge{sub 4}O{sub 14} at 295 and 100 K and analysis of the disorder in the atomic positions

The accurate X-ray diffraction study of a Ca{sub 3}Ga{sub 2}Ge{sub 4}O{sub 14} crystal (sp. gr. P321, Z = 1) has been performed using repeated X-ray diffraction data sets collected on a diffractometer equipped with a CCD area detector at 295 and 100 K. The asymmetric disorder in the atomic positions in Ca{sub 3}Ga{sub 2}Ge{sub 4}O{sub 14} is described in two alternative ways: with the use of anharmonic atomic displacements (at 295 K R/wR = 0.68/0.60%, 3754 reflections; at 100 K R/wR = 0.90/0.70%, 3632 reflections) and using a split model (SM) (at 295 K R/wR = 0.74/0.67%; at 100 K R/wR = 0.95/0.74%). An analysis of the probability density function that defines the probability of finding an atom at a particular point in space shows that, at 295 K, five of the seven independent atoms in the unit cell are asymmetrically disordered in the vicinity of their sites, whereas only three atoms are disordered at 100 K. At both temperatures the largest disorder is observed at the 3f site on a twofold axis, which is a prerequisite for the formation of helicoidal chains of atoms along the c axis of the crystal and can serve as a structural basis for multiferroic properties of this family of crystals with magnetic ions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

On Forbidden Positions in Crystal Space

The finiteness of atomic volumes and symmetry impose limitations on the positions in crystal space that are allowed for occupation when crystal atomic structures are formed. The results of studying the geometric features of the forbidden regions of crystal space are presented. A new classification of symmetry space groups, based on the symmetry of crystal space forbidden regions, is proposed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of the yields of positively charged particles at an angle of 35 Degree-Sign in proton interactions with nuclear targets at an energy of 50 GeV

Momentum spectra of cumulative particles in the region of high transverse momenta (P{sub T}) in pA {yields} h{sup +} + X reactions were obtained for the first time. The experiment in which this was done was performed at the SPIN setup (Institute for High Energy Physics, Protvino) in a beam of 50-GeV protons interacting with C, Al, Cu, and W nuclei. Positively charged particles were detected at a laboratory angle of 35 Degree-Sign and in the transverse-momentum range between 0.6 and 3.7 GeV/c. A strong dependence of the particle-production cross section on the atomic number was observed. A comparison with the results of calculations based on the HIJING and UrQMD models was performed in the subcumulative region.

74 ATOMIC AND MOLECULAR PHYSICS↗

One needs positive signatures for detection of Dark Matter

One believes there is huge amount of Dark Matter particles in our Galaxy which manifest themselves only gravitationally. There is a big challange to prove their existence in a laboratory experiment. To this end it is not sufficient to fight only for the best exclusion curve, one has to see an annual recoil spectrum modulation—the only available positive direct dark matter detection signature. A necessity to measure the recoil spectra is stressed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Renormalization of position space amplitudes in a massless QFT

Ultraviolet renormalization of position space massless Feynman amplitudes has been shown to yield associate homogeneous distributions. Their degree is determined by the degree of divergence while their order—the highest power of logarithm in the dilation anomaly—is given by the number of (sub)divergences. In the present paper we review these results and observe that (convergent) integration over internal vertices does not alter the total degree of (superficial) ultraviolet divergence. For a conformally invariant theory internal integration is also proven to preserve the order of associate homogeneity. The renormalized 4-point amplitudes in the φ{sup 4} theory (in four space-time dimensions) are written as (non-analytic) translation invariant functions of four complex variables with calculable conformal anomaly. Our conclusion concerning the (off-shell) infrared finiteness of the ultraviolet renormalized massless φ{sup 4} theory agrees with the old result of Lowenstein and Zimmermann [23].

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Experimental study of the positive leader velocity as a function of the current in the initial and final-jump phases of a spark discharge

A positive leader in air at gap lengths of up to 8 m was studied experimentally on an open experimental stand. The voltage source was a 6-MV pulsed voltage generator or an artificial charged aerosol cloud. The dependence of the leader velocity on the current in the range 0.2-8 A was determined by simultaneously recording the optical picture and electric parameters of the discharge. Particular attention was paid to the final-jump phase of the discharge, when the gap was completely bridged by the streamer zone of the leader. It is shown that the character of the dependence of the leader velocity on the current in this phase remains unchanged; hence, the final-jump phase can be used in experiments in which the current has to be varied within a wide range. For this purpose, one can use a damping resistance, which is inefficient in the initial phase. The parameters of the power-law dependence of the leader velocity on the current at currents of a few amperes are established reliably. It is found that the power-law dependence with constant parameters is inapplicable to calculate the leader velocity at currents of about 0.1 A, which correspond to the lower limit of the leader viability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗