Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance tests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Experimental Evaluation of Heat Transfer in a High Temperature High Pressure Test Facility

Performance of film cooling holes is generally evaluated near ambient conditions, so scaling the film cooling performance from ambient to engine conditions is important. These performance metrics can be reported in terms of net heat flux reduction, heat transfer enhancement, and effectiveness. There are several challenges and penalties in conducting experiments on a real engine or even on a stationary flat plate test article at near engine conditions. In this study, an experimental methodology capable of delivering film cooling performance for the experiments conducted in the high-temperature high-pressure test facility at NETL will be explored. More specifically, this study focuses on various challenges that are present and how these concerns are addressed to evaluate the heat transfer coefficient on the test article. Steady state experiments were conducted on a flat plate test article whose surface temperature distribution was obtained using an IR camera calibrated with a combination of bench top experiments and in-situ calibrations based on embedded thermocouple measurements. A detailed radiation analysis is conducted to enable differentiation of heat transfer by convection from heat transfer by radiation. The estimated surface heat flux and heat transfer coefficient were found to be higher than the one obtained from flat plate correlation.

Ramesh, Sridharan↗

Sludge Batch 5 Slurry Fed Melt Rate Furnace Test with Frits 418 and 550

Based on Melt Rate Furnace (MRF) testing for the Sludge Batch 5 (SB5) projected composition and assessments of the potential frits with reasonable operating windows, the Savannah River National Laboratory (SRNL) recommended Slurry Fed Melt Rate Furnace (SMRF) testing with Frits 418 and 550. DWPF is currently using Frit 418 with SB5 based on SRNL's recommendation due to its ability to accommodate significant sodium variation in the sludge composition. However, experience with high boron containing frits in DWPF indicated a potential advantage for Frit 550 might exist. Therefore, SRNL performed SMRF testing to assess Frit 550's potential advantages. The results of SMRF testing with SB5 simulant indicate that there is no appreciable difference in melt rate between Frit 418 and Frit 550 at a targeted 34 weight % waste loading. Both batches exhibited comparable behavior when delivered through the feed tube by the peristaltic pump. Limited observation of the cold cap during both runs showed no indication of major cold cap mounding. MRF testing, performed after the SMRF runs due to time constraints, with the same two Slurry Mix Evaporator (SME) dried products led to the same conclusion. Although visual observations of the cross-sectioned MRF beakers indicated differences in the appearance of the two systems, the measured melt rates were both {approx}0.6 in/hr. Therefore, SRNL does not recommend a change from Frit 418 for the initial SB5 processing in DWPF. Once the actual SB5 composition is known and revised projections of SB5 after the neptunium stream addition and any decants is provided, SRNL will perform an additional compositional window assessment with Frit 418. If requested, SRNL can also include other potential frits in this assessment should processing of SB5 with Frit 418 result in less than desirable melter throughput in DWPF. The frits would then be subjected to melt rate testing at SRNL to determine any potential advantages.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The EGS Collab project: Outcomes and lessons learned from hydraulic fracture stimulations in crystalline rock at 1.25 and 1.5 km depth

With the goal of better understanding stimulation in crystalline rock for improving enhanced geothermal systems (EGS), the EGS Collab Project performed a series of stimulations and flow tests at 1.25 and 1.5 km depths. The tests were performed in two well-instrumented testbeds in the Sanford Underground Research Facility in Lead, South Dakota, United States. The testbed for Experiment 1 at 1.5 km depth contained two open wells for injection and production and six instrumented monitoring wells surrounding the targeted stimulation zone. Four multi-step stimulation tests targeting hydraulic fracturing and nearly year-long ambient temperature and chilled water flow tests were performed in Experiment 1. The testbed for Experiments 2 and 3 was at 1.25 km depth and contained five open wells in an outwardly fanning five-spot pattern and two fans of well-instrumented monitoring wells surrounding the targeted stimulation zone. Experiment 2 targeted shear stimulation, and Experiment 3 targeted low-flow, high-flow, and oscillating pressure stimulation strategies. Hydraulic fracturing was successful in Experiments 1 and 3 in generating a connected system wherein injected water could be collected. However, the resulting flow was distributed dynamically, and not entirely collected at the anticipated production well. Thermal breakthrough was not observed in the production well, but that could have been masked by the Joule-Thomson effect. Shear stimulation in Experiment 2 did not occur - despite attempting to pressurize the fractures most likely to shear - because of the inability to inject water into a mostly-healed fracture, and the low shear-to-normal stress ratio. The EGS Collab experiments are described to provide a background for lessons learned on topics including induced seismicity, the correlation between seismicity and permeability, distributed and dynamic flow systems, thermoelastic and pressure effects, shear stimulation, local geology, thermal breakthrough, monitoring stimulation, grouting boreholes, modeling, and system management.

15 - GEOTHERMAL ENERGY↗

Post mortem results of laser-optical system packaged for use in harsh environments

In this study, the design and packaging of laser-optical system was tested to harsh environments outside lab conditions and post mortem activities will be discussed. Previously, custom mounts and bonded optical assemblies were environmentally tested to ensure their survivability. The results verified the sub-assemblies would enable the design of a laser-optical initiation system that could be fielded for use in extreme conditions. The design package, which utilized the proven opto-mechanical sub-assemblies, was then tested to the same levels as the sub-assemblies. The test regiment encompassed the harshest environments currently utilized. Temperature tests were performed ranging from a maximum of +75 degrees C to a minimum of -55 degrees C, allowing for two hour soak at each temperature set point. Vibration tests were performed to a maximum level of 15.5 grms for forty seconds in each of three critical axes. Shock tests were performed to a maximum impulse level of 5700 G's for the sub-assemblies with a 1.1 millisecond long pulse; whereas the packaged laser system maximum level reached was 3700 G's at 1.1 millisecond long pulse. The laser-optical assembly was visually inspected and functionally tested before and after each test to verify survival. As designed, the system covers were laser welded shut for hermetic seal. The only open port was the laser output for testing and verification of laser performance. No optical cables were utilized. Therefore the visual inspection of the interior was performed post mortem. Finally, the post mortem results will be discussed as will the potential of redesigns on future packaging strategies.

42 ENGINEERING↗

Comparison of the performance of TLD, OSL and RPL personal dosimetry systems to the American National Standard Institute (ANSI) test categories

The Laboratory Accreditation Program (LAP) tests the capability and performance of the United States Department of Energy's (USDOE) facilities to accurately measure and quantify the whole-body and extremity radiation equivalent doses to the occupational workers. The dosimetry methods used in personal dosimetry can be Thermoluminescence (TL), Optically Stimulated Luminescence (OSL) and Radiophotoluminescence (RPL), among other techniques available. Currently, the TL (LiF:Mg,Ti) and OSL (Al 2 O 3 :C) dosimetry systems are DOELAP-accredited for occupational dose measurements and regulatory reporting. In this study, the performance of a beryllium oxide (BeO) OSL dosimetry system and of a silver-doped phosphate glass RPL dosimetry system is compared against the performance of an accredited LiF:Mg,Ti TL dosimetry system. The bias and standard deviation in each of the performance test categories are compared between these three systems for exposures to photons, beta, and mixed radiation fields with the criteria established by the American National Standard Institute (ANSI) and Health Physics Society (HPS) N13.11-2022 standard. The practical implementation of the dosimetry program and its equivalency to the occupational personal equivalent dose H p (0.07) and H p (10) measurements were evaluated. The TL, OSL and RPL dosimetry systems passed the ANSI performance test criteria for H p (0.07) and H p (10) occupational dose measurements and met the DOELAP accreditation requirements.

61 RADIATION PROTECTION AND DOSIMETRY↗

Experimental Investigation of Drillstring Torsional Vibration Effect on Rate of Penetration with PDC Bits in Hard Rock

Polycrystalline diamond compact (PDC) bits have shown tremendous performance compared to roller cone bits and have gained attraction in deep geothermal drilling applications. While PDC bits can reach a higher rate of penetration compared to other bits, they are more prone to drilling vibrations. The scope of this paper is to quantify the effects of drillstring torsional vibrations on PDC bit performance using a laboratory testing facility. Here, the tests were performed with three drillstring configurations to evaluate the effect of drillstring vibrations. The results showed that rigid testing overestimates the bit rate of penetration by 35% due to torsional vibrations.

15 GEOTHERMAL ENERGY↗

Post-Transient Examination Results of RIA Commissioning Teats at the Transient Reactor Test Facility

Six reactivity-initiated-accident (RIA) commissioning tests have been performed at Idaho National Laboratory’s (INL) Transient Reactor Test Facility. Five of these tests were performed using fresh fuel rodlets, and the sixth test was performed using a previously irradiated rodlet from the ATF-2 irradiation experiment. These experiments demonstrate the ability to perform RIA testing including the ability to perform experiments using previously irradiated materials. Post-transient examinations revealed pellet cladding interactions and cladding ballooning depending on the initial boundary conditions of the test. Increased thickness of both zirconium oxide and alpha-zirconium were found in the cladding with tests performed at higher levels of total energy deposition. No oxide or alpha-zirconium was found in the test with the greatest amount of ballooning, which was also the test with the highest initial rod internal pressure. The highest energy deposition test (1110 J/g) resulted in failure of the rodlet. Fragmentation of the fuel pellets occurred in this test with the size of the fragments decreasing inversely to the pellet radius.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fatigue crack growth rates of X100 steel welds in high pressure hydrogen gas considering residual stress effects

Fatigue crack growth rate (FCGR) data were measured in high pressure hydrogen gas versus stress intensity factor range (ΔK) in specimens removed from a X100 welded steel pipe. Three distinct regions of the pipe weld were examined: base metal, weld fusion zone, and heat affected zone. Tests were performed at a load ratio (R) of 0.5, frequency of 1 Hz, and at a hydrogen gas pressure of 21 MPa. Tests were also performed in air at 10 Hz as a reference. Fatigue crack growth rates were observed to be over an order of magnitude higher for tests performed in hydrogen compared to the rates from tests in air. Residual stress measurements were collected on identical specimens cut from the base metal, weld, and heat affected zone to account for their influence on measured FCGR data. The slitting method provided residual stress and residual stress intensity factor (K res ), the effect of which was removed from the FCGR data using K norm in order to provide a more direct comparison of crack growth resistance of the base metal, weld and heat affected zone. Prior to accounting for residual stress, FCGR in hydrogen gas appeared to be highest in the weld fusion zone. Furthermore, after accounting for residual stress effects, the weld fusion zone FCGR data converged to the base metal FCGR data, which underscores the importance of accounting for residual stress effects when assessing fatigue performance.

42 ENGINEERING↗

Testing of ENDF71x: A new ACE-formatted neutron data library based on ENDF/B-VII.1

The ENDF71x library [1] is the most thoroughly tested set of ACE-format data tables ever released by the Nuclear Data Team at Los Alamos National Laboratory (LANL). It is based on ENDF/B-VII. 1, the most recently released set of evaluated nuclear data files produced by the US Cross Section Evaluation Working Group (CSEWG). A variety of techniques were used to test and verify the ENDF7 1x library before its public release. These include the use of automated checking codes written by members of the Nuclear Data Team, visual inspections of key neutron data, MCNP6 calculations designed to test data for every included combination of isotope and temperature as comprehensively as possible, and direct comparisons between ENDF71x and previous ACE library releases. Visual inspection of some of the most important neutron data revealed energy balance problems and unphysical discontinuities in the cross sections for some nuclides. Doppler broadening of the total cross sections with increasing temperature was found to be qualitatively correct. Test calculations performed using MCNP prompted two modifications to the MCNP6 source code and also exposed bad secondary neutron yields for {sup 231,233}Pa that are present in both ENDF/B-VII.1 and ENDF/B-VII.0. A comparison of ENDF71x with its predecessor ACE library, ENDF70, showed that dramatic changes have been made in the neutron cross section data for a number of isotopes between ENDF/B-VII.0 and ENDF/B-VII.1. Based on the results of these verification tests and the validation tests performed by Kahler, et al. [2], the ENDF71x library is recommended for use in all Monte Carlo applications. (authors)

97 MATHEMATICS AND COMPUTING↗

Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters

This paper explores the laboratory performance of five integrated Heat Pump Water Heaters (HPWHs) across a wide range of operating conditions representative of U.S. climate regions. HPWHs are expected to provide significant energy savings in certain climate zones when compared to typical electric resistance water heaters. Results show that this technology is a viable option in most climates, but differences in control schemes and design features impact the performance of the units tested. Tests were conducted to map heat pump performance across the operating range and to determine the logic used to control the heat pump and the backup electric heaters. Other tests performed include two unique draw profile tests, reduced air flow performance tests and the standard DOE rating tests. The results from all these tests are presented here for all five units tested. The results of these tests will be used to improve the EnergyPlus heat pump water heater for use in BEopt™ whole-house building simulations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Testing ΛCDM at the lowest redshifts with SN Ia and galaxy velocities

Peculiar velocities of objects in the nearby universe are correlated due to the gravitational pull of large-scale structure. By measuring these velocities, we have a unique opportunity to test the cosmological model at the lowest redshifts. We perform this test, using current data to constrain the amplitude of the "signal" covariance matrix describing the velocities and their correlations. We consider a new, well-calibrated "Supercal" set of low-redshift SNe Ia as well as a set of distances derived from the fundamental plane relation of 6dFGS galaxies. Here, analyzing the SN and galaxy data separately, both results are consistent with the peculiar velocity signal of our fiducial ΛCDM model, ruling out the noise-only model with zero peculiar velocities at greater than 7σ (SNe) and 8σ (galaxies). When the two data sets are combined appropriately, the precision of the test increases slightly, resulting in a constraint on the signal amplitude of A = 1.05 -0.21 +0.25 where A = 1 corresponds to our fiducial model. Equivalently, we report an 11% measurement of the product of the growth rate and amplitude of mass fluctuations evaluated at z eff = 0.02, f σ 8 = 0.428 -0.045 +0.048 , valid for our fiducial ΛCDM model. Here, we explore the robustness of the results to a number of conceivable variations in the analysis and find that individual variations shift the preferred signal amplitude by less than ~0.5σ. We briefly discuss our Supercal SN Ia results in comparison with our previous results using the JLA compilation.

79 ASTRONOMY AND ASTROPHYSICS↗

Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters

This paper explores the laboratory performance of five integrated Heat Pump Water Heaters (HPWHs) across a wide range of operating conditions representative of US climate regions. HPWHs are expected to provide significant energy savings in certain climate zones when compared to typical electric resistance water heaters. Results show that this technology is a viable option in most climates, but differences in control schemes and design features impact the performance of the units tested. Tests were conducted to map heat pump performance across the operating range and to determine the logic used to control the heat pump and the backup electric heaters. Other tests performed include two unique draw profile tests, reduced air flow performance tests and the standard DOE rating tests. The results from all these tests are presented here for all five units tested. The results of these tests will be used to improve the EnergyPlus heat pump water heater for use in BEopt(tm) whole-house building simulations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Steady-State Comparison of GS-IHP Field Data to Modeled Performance

Field tests were conducted over the winter and summer of 2011 on a prototype (ground-source integrated heat pump (GS-IHP) in Oak Ridge, TN. The extensive field test data was filtered to provide a subset of near-steady-state operation data suitable for comparison to modeled steadystate performance. On-site power use characteristics of the compressor, blower, and pumps and other operational measurements were used to calibrate the system model. Comparisons were made for four modes of operation: space heating, dedicated water heating, space cooling, and combined space cooling and water heating. Analysis results suggest that the field unit was undercharged, especially in the combined space cooling and water heating mode. The fully calibrated model agreed on average to within 2% on capacity, power, and COP/EER for the space heating and cooling modes. Average differences were larger for the water heating modes, ranging from 3 to 11%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radiation-Hardened Circuitry Using Mask-Programmable Analog Arrays: Report 3

As the recent accident at Fukushima Daiichi so vividly demonstrated, telerobotic technologies capable of withstanding high radiation environments need to be readily available to enable operations, repair, and recovery under severe accident scenarios when human entry is extremely dangerous or not possible. Telerobotic technologies that enable remote operation in high dose rate environments have undergone revolutionary improvement over the past few decades. However, much of this technology cannot be employed in nuclear power environments because of the radiation sensitivity of the electronics and the organic insulator materials currently in use. This is a report of the activities involving Task 3 of the Nuclear Energy Enabling Technologies (NEET) 2 project Radiation Hardened Circuitry Using Mask-Programmable Analog Arrays. Evaluation of the performance of the system for both pre- and post-irradiation as well as operation at elevated temperature will be performed. Detailed performance of the system will be documented to ensure the design meets requirements prior to any extended evaluation. A suite of tests will be developed which will allow evaluation before and after irradiation and during temperature. Selection of the radiation exposure facilities will be determined in the early phase of the project. Radiation exposure will consist of total integrated dose (TID) up to 200 kRad or above with several intermediate doses during test. Dose rates will be in various ranges determined by the facility that will be used with a target of 30 kRad/hr. Many samples of the pre-commercial devices to be used will have been tested in previous projects to doses of at least 300 kRad and temperatures up to 125C. The complete systems will therefore be tested for performance at intermediate doses. Extended temperature testing will be performed up to the limit of the commercial sensors. The test suite performed at each test point will consist of operational testing of the three basic measurement functions plus electronic functional testing (power dissipation, voltage offset changes, noise variations, etc.). This suite will be developed as part of this task.

42 ENGINEERING↗

Distributed fiber sensing systems for 3D combustion temperature field monitoring in coal-fired boilers using optically generated acoustic waves (Final Report)

In this project, we have developed and tested three kinds of fiber optic sensing systems for real time monitoring of temperature variations within an industrial scale boiler furnace. The fiber optic sensing systems target spatial and temporal distributions of high temperature profiles in a boiler furnace in fossil power plants. The reconstructed temperature profile will provide critical input for the control mechanisms to optimize the combustion process. This temperature profile will address the essential problem for fossil power plants in achieving higher efficiency and fewer pollutant emissions. Acoustic pyrometer systems have been used to reconstruct temperature field of power plant boilers based on measuring TOF (times-of-flight) of sound waves along some straight paths in a 2D cross-section of the boiler. In this project, optically generated acoustic signals from a fiber optic sensing system have replaced the acoustic signals generated from an electrical transducer. A 3D reconstruction algorithm replaced the previous 2D model. In this project, three kinds of fiber optic sensing systems have been developed and tested. They are fiber optic sensing system I, fiber optic sensing system II (Distributed Sensing System I) and fiber optic sensing system III (Distributed Sensing System II). For fiber optic sensing system I, the fiber optic ultrasound generator acts as a signal generator. A microphone, hydrophone or other electronic devices serve as a signal receiver. In this system, there are one generator and one receiver. Distance test, water temperature test, air temperature test, air temperature reconstruction, and GE ISBF pilot test were performed by Fiber optic sensing system I. The fiber optic sensing system I successfully detected temperature in all these tests. We got 2D temperature reconstruction results by using the fiber optic sensing system I and it matched the reference data. The fiber optic sensing system I successfully survived in GE ISBF boiler environment (480 °F). For fiber optic sensing system II (Distributed Sensing System I), it is an all optical ultrasound system. The fiber optic ultrasound generator acts as a signal generator. Fiber Bragg Grating (FBG) and Fabry-Perot (FP) sensor act as a signal receiver. In this system, there is one generator and one receiver. Aluminum plate temperature test, furnace high temperature test, and GE ISBF pilot test were performed by the fiber optic sensing system II. Fiber optic sensing system II successfully detected the temperature in all these tests. The fiber optic sensing system II successfully survived at up to 700 °C furnace environment and 320 °C GE ISBF boiler environment. For fiber optic sensing system III (Distributed Sensing System II), it is also an all optical ultrasound system. The fiber optic ultrasound generator acts as a signal generator. Multiple FP fiber sensors act as signal receivers. In this system, there is one generator and three receivers. Three GE ISBF pilot tests were performed by fiber optic sensing system III. The fiber optic sensing system III survived in the cold flow tests in GE’s ISBF pilot test facility. However, we didn’t get high temperature data by using this system since the nanosecond laser issues. During the period of the project, test trials, data simulation and algorithm optimization was performed successfully. For real time temperature field construction, the sampling rate must be fast enough to capture the field variations. The technology of Code-division multiple access (CDMA) is well studied which could allow parallel multiplexing, even if signals overlap in time or frequencies. Moreover, it has been known that extending the length of signal significantly improves SNR. For acoustic signals, these multiplexing techniques have also been widely used, mainly for sonar and acoustic communications. The CDMA modulation technique has been proposed and studied to guarantee high network throughput, low channel access delay and low energy consumption. We have studied the temperature field reconstruction using Gaussian Radial Basis Functions (GRBF)-based approximation approach. Reconstruction of 3D temperature field using Neural Networks with measured TOF and known propagation paths is feasible. 2D and 3D temperature field reconstruction simulation results are achieved. The milestone status is shown in Table 1. We finished milestone 1-8 and milestone 10. For milestone 9, we did three pilot tests by using the fiber optic sensing system III (Distributed Sensing System II) at GE Power. However, due to the failure of the ns laser, we did not get the temperature results. We conducted some additional tasks that were not originally proposed: 1) We fabricated a fiber optic sensing system I and did a pilot test based on this system. 2) In the proposal, we proposed two pilot tests at GE Power. In reality, we finished at least seven pilot tests at GE Power. GE Power has made a lot of efforts for supporting the pilot tests. 3) We got a simulation results based on CDMA. In summary, most of the tasks have been accomplished. The outcome of this project removed a few barriers that hinder the achievement of the final product of the distributed sensing systems. With the successful accomplishment of this project, a prototype of the fiber optic sensing system can be fabricated to attract more interests from companies and other funding agencies.

47 OTHER INSTRUMENTATION↗

Multi-Column Xe/Kr Separation with AgZ-PAN and HZ-PAN

Previous multi-column xenon/krypton separation tests have demonstrated the capability of separating xenon from krypton in a mixed gas feed stream. The results of this initial testing with AgZ-PAN and HZ-PAN indicated that an excellent separation of xenon from krypton could be achieved. Building upon these initial results, a series of additional multi-column testing were performed in FY-16. The purpose of this testing was to scale up the sorbent beds, test a different composition of feed gas and attempt to improve the accuracy of the analysis of the individual capture columns’ compositions. Two Stirling coolers were installed in series to perform this testing. The use of the coolers instead of the cryostat provided two desired improvements, 1) removal of the large dilution due to the internal volume of the cryostat adsorption chamber, and 2) ability to increase the sorbent bed size for scale-up. The AgZ-PAN sorbent, due to its xenon selectivity, was loaded in the first column to capture the xenon while allowing the krypton to flow through and be routed to a second column containing the HZ-PAN for capture and analysis. The gases captured on both columns were sampled with evacuated sample bombs and subsequently analyzed via GC-MS for both krypton and xenon. The results of these tests can be used to develop the scope of future testing and analysis using this test bed for demonstrating the capture and separation of xenon and krypton using sorbents, for demonstrating desorption and regeneration of the sorbents, and for determining compositions of the desorbed gases. They indicate a need for future desorption studies in order to better quantify co-adsorbed species and final krypton purity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determination of the Impact of Glycolate on ARP and MCU Operations

Savannah River Remediation (SRR) is evaluating an alternate flowsheet for the Defense Waste Processing Facility (DWPF) using glycolic acid as a reductant. An important aspect of the development of the glycolic acid flowsheet is determining if glycolate has any detrimental downstream impacts. Testing was performed to determine if there is any impact to the strontium and actinide sorption by monosodium titanate (MST) and modified monosodium titanate (mMST) or if there is an impact to the cesium removal, phase separation, or coalescer performance at the Modular Caustic-Side Solvent Extraction Processing Unit (MCU). Sorption testing was performed using both MST and modified MST (mMST) in the presence of 5000 and 10,000 ppm (mass basis) glycolate. 10,000 ppm is the estimated bounding concentration expected in the DWPF recycle stream based on DWPF melter flammable gas model results. The presence of glycolate was found to slow the removal of Sr and Pu by MST, while increasing the removal rate of Np. Results indicate that the impact is a kinetic effect, and the overall capacity of the material is not affected. There was no measurable effect on U removal at either glycolate concentration. The slower removal rates for Sr and Pu at 5000 and 10,000 ppm glycolate could result in lower DF values for these sorbates in ARP based on the current (12 hours) and proposed (8 hours) contact times. For the highest glycolate concentration used in this study, the percentage of Sr removed at 6 hours of contact decreased by 1% and the percentage of Pu removed decreased by nearly 7%. The impact may prove insignificant if the concentration of glycolate that is returned to the tank farm is well below the concentrations tested in this study. The presence of glycolate also decreased the removal rates for all three sorbates (Sr, Pu, and Np) by mMST. Similar to MST, the results for mMST indicate that the impact is a kinetic effect, and the overall capacity of the material is not affected. The presence of glycolate did not change the lack of affinity of mMST for U. Pre-contacting the MST or mMST with glycolate did not have a significant effect on the performance of the materials when compared to tests having the same concentration of glycolate present in the simulant. These findings suggest that the glycolate is likely influencing removal by sorbate complexation and not by depositing onto or forming a film on the surface of the MST solids. Since the DF values are salt batch dependent, it is not possible to a priori quantify the impacts of glycolate on future processing campaigns. However, we recommend that the impacts of glycolate be evaluated during each salt batch qualification when a final processing concentration is defined, and recommendations can then be made on how to mitigate negative impacts, if needed. Impacts to the performance of the MST or mMST could be mitigated by increasing contact time or increasing sorbent concentrations. Testing was performed to determine if there is an impact to the cesium removal at Modular Caustic-Side Solvent Extraction Processing Unit (MCU). An Extraction-Scrub-Strip (ESS) test routine was used to simulate cesium removal at the MCU. For this, SRNL performed three ESS tests, using the same basic aqueous waste simulant and solvent. For one test, SRNL added 5000 ppm (mass basis) of glycolate and added 10,000 ppm of glycolate to a second test. A control test contained no glycolate. The results of all three tests were virtually identical for all the extraction, scrub and strip tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Study on Emulsification/Demulsification Behavior and Mechanism of Produced Liquid from Polymer Flooding on Alaska North Slope

Heavy oil reservoirs on Alaska North Slope (ANS) are unconsolidated and contain abundant clay minerals, where the first-ever field pilot is currently implemented to validate the use of polymer floods for heavy oil enhanced oil recovery (EOR). The polymer molecules and/or fine clay particles carried with the produced liquid could potentially affect the oil/water separation, which is one of the major concerns for field operators. This dissertation aims to investigate the emulsification behavior of produced liquid, understand the emulsifying mechanism, and seek an adaptive and cost-effective method to treat the produced liquid from polymer flooding. Emulsions were prepared by mechanically mixing the actual heavy oil and the produced water from the pilot site, of which the stability was investigated by bottle test method or multiple light scattering method. Drop size distribution and interfacial properties were measured via microscope and pendant drop technique to probe the stability mechanism further. Results showed that oil-continuous or water-continuous emulsion could be generated depending on the water cut, clay types, clay concentration, and polymer concentration. In the crude oil/water system, the increasing water cut triggered the phase inversion of oil-continuous emulsion to water-continuous emulsion, resulting in faster separation and lower emulsion stability. Whereas, clay particles, no matter added to the oil or water phase, resulted in an unfavorable phase inversion from the loose water-continuous emulsion to the tight oil-continuous emulsion as clay concentration increased. For all four types of clay except Ca-montmorillonite, clay particles added to water led to an earlier phase inversion and higher emulsion stability than that added to the oil. The dual function of polymer on emulsion stability was observed. On the one hand, both sheared and unsheared polymer tended to convert the oil-continuous emulsion formed in either crude oil/water system or complex crude oil/water/clay particle system to the water-continuous emulsion, acting as a weak demulsifier to accelerate the oil/water separation. On the other hand, the addition of polymer to the water-continuous emulsion could result in enhanced emulsion stability, which is primarily attributed to the increased viscosity of the continuous phase and the decreased drop size of the dispersed oil phase. Particularly, the sheared polymer had a weaker ability to stabilize the o/w emulsion than the unsheared polymer due to the lower viscosity of the sheared polymer solution resulting from the breakdown of the polymer macromolecules. As for the chemical demulsification tests, the performance of demulsifiers showed a complex dependency upon the water cut, the shearing intensity, demulsifier type and dosage, and the polymer concentration. A compound emulsion breaker, E12+E18, exhibited the most satisfactory demulsification performance despite the varied test conditions. For severe water-continuous emulsions that might require a multi-fold dosage of demulsifier, a less expensive electrolyte, KCl, was proposed to be used in combination with demulsifier E12+E18 to improve the demulsification performance. In the proposed demulsifier formula, the effectiveness of the commercial demulsifier relied on its destructive effect on the interfacial film, while the efficacy of KCl was mainly dependent on its viscosity reduction effect on the continuous phase. This dissertation illustrates that intermediate layer elimination and water clarification are the major challenges for produced liquid treatment from polymer flooding. It also provides practical and theoretical guidance in advance for the demulsification strategy of the produced liquid from the ongoing first-ever polymer flooding pilot on ANS.

Chang, Hongli↗