Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PERFORMANCE CHARACTERISTICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Exploring the All-to-All Collective Optimization Space with ConnectX CORE-Direct

The all-to-all collective communication operation is used by many scientific applications, and is one of the most time consuming and challenging collective operation to optimize. The algorithms for all-to-all operations typically fall into two classes, logarithmic and linear scaling algorithms, with Bruck's algorithm, a logarithmic scaling algorithm, used in many small-data all-to-all implementations. The recent addition of InfiniBand CORE-Direct support for network management of collective communications offers new opportunities for optimizing all-to-all operation as well as supporting truly asynchronous implementations of these operations. This paper presents several new enhancements to the Bruck small-data algorithm that leverage CORE-Direct and other InfiniBand network capabilities to produce efficient implementations of this collective operation. These include RDMA, SR-RNR, and SR-RTR algorithms. In addition, nonblocking implementations of these collective operations are also presented. Benchmark results show that the RDMA algorithm, which uses CORE-Direct capabilities to offload collective communication management to the Host Channel Adapter (HCA), hardware gather support for sending non-continuous data, and low-latency RDMA semantics, performs the best. For a 64 processes and 128 byte-per-process all-to-all, the RDMA algorithm performs 27% better than Bruck's algorithm implementation in Open MPI and 136% better than the SR-RTR algorithm. In addition, the nonblocking versions of these algorithms have the same performance characteristics as the blocking algorithms. Finally, measurements of computation/communication overlap capacity show that all offloaded algorithms achieve about 98% overlap for large data all-to-all, whereas implementations using host-based progress achieve only about 9.5% overlap.

Venkata, Manjunath Gorentla↗

Optimizing Sparse Matrix-Multiple Vectors Multiplication for Nuclear Configuration Interaction Calculations

Obtaining highly accurate predictions on the properties of light atomic nuclei using the configuration interaction (CI) approach requires computing a few extremal Eigen pairs of the many-body nuclear Hamiltonian matrix. In the Many-body Fermion Dynamics for nuclei (MFDn) code, a block Eigen solver is used for this purpose. Due to the large size of the sparse matrices involved, a significant fraction of the time spent on the Eigen value computations is associated with the multiplication of a sparse matrix (and the transpose of that matrix) with multiple vectors (SpMM and SpMM-T). Existing implementations of SpMM and SpMM-T significantly underperform expectations. Thus, in this paper, we present and analyze optimized implementations of SpMM and SpMM-T. We base our implementation on the compressed sparse blocks (CSB) matrix format and target systems with multi-core architectures. We develop a performance model that allows us to understand and estimate the performance characteristics of our SpMM kernel implementations, and demonstrate the efficiency of our implementation on a series of real-world matrices extracted from MFDn. In particular, we obtain 3-4 speedup on the requisite operations over good implementations based on the commonly used compressed sparse row (CSR) matrix format. The improvements in the SpMM kernel suggest we may attain roughly a 40% speed up in the overall execution time of the block Eigen solver used in MFDn.

97 MATHEMATICS AND COMPUTING↗

Synchronization Algorithms for Co-Simulation of Power Grid and Communication Networks

The ongoing modernization of power grids consists of integrating them with communication networks in order to achieve robust and resilient control of grid operations. To understand the operation of the new smart grid, one approach is to use simulation software. Unfortunately, current power grid simulators at best utilize inadequate approximations to simulate communication networks, if at all. Cooperative simulation of specialized power grid and communication network simulators promises to more accurately reproduce the interactions of real smart grid deployments. However, co-simulation is a challenging problem. A co-simulation must manage the exchange of informa- tion, including the synchronization of simulator clocks, between all simulators while maintaining adequate computational perfor- mance. This paper describes two new conservative algorithms for reducing the overhead of time synchronization, namely Active Set Conservative and Reactive Conservative. We provide a detailed analysis of their performance characteristics with respect to the current state of the art including both conservative and optimistic synchronization algorithms. In addition, we provide guidelines for selecting the appropriate synchronization algorithm based on the requirements of the co-simulation. The newly proposed algorithms are shown to achieve as much as 14% and 63% im- provement, respectively, over the existing conservative algorithm.

co-simulation↗

Atomic Scale Understanding of Poly-Si/SiO2/c-Si Passivated Contacts: Passivation Degradation Due to Metallization

The key attributes for achieving high efficiency crystalline silicon solar cells include class leading developments in the ability to approach the theoretical limits of silicon solar technology (29.4% efficiency). The push for high efficiency devices is further compounded with the clear need for passivation to reduce recombination at the metal contacts. At the same time there is stringent requirement to retain the same material device quality, surface passivation, and performance characteristics following subsequent processing. The development of passivated silicon cell structures that retain active front and rear surface passivation and overall material cell quality is therefore a relevant and active area of development. To address the potential outcomes of metallization on passivated silicon stack, we report on some common microstructural features of degradation due to metallization for a series of silicon device stacks. A fundamental materials understanding of the metallization process on retaining high-efficiency passivated Si devices is therefore gained over these series of results.

14 SOLAR ENERGY↗

Towards Integrating Data Quality Assessments and Radiometer Uncertainty for Determining the Expanded Uncertainty of Three-Component Solar Radiation Measurements

Accurate solar irradiance data are fundamental for determining the design and performance characteristics of photovoltaic systems. The uncertainty of solar irradiance measurements depends on many factors including radiometer design, calibration, installation, maintenance, and operational environment. The key contributors to this uncertainty can be classified as the measurement uncertainty of a particular radiometer and the operational uncertainty determined for the time of measurement. Radiometer measurement uncertainty estimates (U R ) can be based on well-established methods used as part of the radiometer calibration process. Estimates of operational uncertainties (U o ) require consideration of additional site-specific factors that affect data quality. A method is needed for establishing the accuracy of solar irradiance data by integrating an existing data quality process and measurement uncertainty estimates for specific radiometers. An algorithm has been developed to integrate data quality analyses and measurement uncertainty estimates for three-component solar irradiance data: global horizontal (total hemispheric) irradiance, direct normal (beam) irradiance, and diffuse horizontal (sky) irradiance collected at one- to 60-minute intervals. The algorithm has been tested using one-minute irradiance measurements. The goal of the project is to distribute a user-friendly software package based on the new algorithm.

data integrity↗

A Comprehensive Comparison of Current Operating Reserve Methodologies

Electric power systems are currently experiencing a paradigm shift from a traditionally static system to a system that is becoming increasingly more dynamic and variable. Emerging technologies are forcing power system operators to adapt to their performance characteristics. These technologies, such as distributed generation and energy storage systems, have changed the traditional idea of a distribution system with power flowing in one direction into a distribution system with bidirectional flows. Variable generation, in the form of wind and solar generation, also increases the variability and uncertainty in the system. As such, power system operators are revisiting the ways in which they treat this evolving power system, namely by modifying their operating reserve methodologies. This paper intends to show an in-depth analysis on different operating reserve methodologies and investigate their impacts on power system reliability and economic efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic Adaptable Asynchronous Progress Model for MPI RMA Multiphase Applications

Casper is a process-based asynchronous progress model for MPI one-sided communication on multi-and many-core architectures. The one-sided communication is not truly one-sided in most MPI implementations: the target process still relies on software progress to complete incoming operations. Casper allows the user to specify an arbitrary number of cores dedicated to background ghost processes and transparently redirects the RMA operations to ghost processes by utilizing the PMPI redirection and MPI-3 shared-memory technologies. Although Casper benefits applications that suffer from lack of asynchronous progress, the operation redirection design might not support complex multiphase applications effectively, which often involve dynamically changing communication density and computing workloads. In this paper, we present an adaptive mechanism in Casper to address the limitation of static asynchronous progress in multiphase applications. For this we exploit two adaptive strategies, a user-guided strategy and a fully transparent and automatic strategy based on self-profiling and prediction, to dynamically reconfigure the asynchronous progress in Casper according to real-time performance characteristics during multiphase execution. We evaluate the adaptive approaches in both microbenchmarks and a real quantum chemistry application suite, NWChem, on the Cray XC30 supercomputer and an Intel Omni-Path cluster.

97 MATHEMATICS AND COMPUTING↗

Simulated Fuel Economy and Performance of Advanced Hybrid Electric and Plug-in Hybrid Electric Vehicles Using In-Use Travel Profiles

As vehicle powertrain efficiency increases through electrification, consumer travel and driving behavior have significantly more influence on the potential fuel consumption of these vehicles. Therefore, it is critical to have a good understanding of in-use or 'real world' driving behavior if accurate fuel consumption estimates of electric drive vehicles are to be achieved. Regional travel surveysusing Global Positioning System (GPS) equipment have been found to provide an excellent source of in-use driving profiles. In this study, a variety of vehicle powertrain options were developed and their performance was simulated over GPS-derived driving profiles for 783 vehicles operating in Texas. The results include statistical comparisons of the driving profiles versus national data sets,driving performance characteristics compared with standard drive cycles, and expected petroleum displacement benefits from the electrified vehicles given various vehicle charging scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Waste handling and storage in the decontamination pilot projects of JAEA for environments of Fukushima

After the Fukushima Daiichi nuclear accident, Japan Atomic Energy Agency (JAEA) was chosen by the national government to conduct decontamination pilot projects at selected sites in Fukushima prefecture. Despite tight boundary conditions in terms of timescale and resources, the projects served their primary purpose to develop a knowledge base to support more effective planning and implementation of stepwise regional remediation of the evacuated zone. A range of established, modified and newly developed techniques were tested under realistic field conditions and their performance characteristics were determined. The results of the project can be summarized in terms of site characterization, cleanup and waste management. A range of options were investigated to reduce the volumes of waste produced and to ensure that decontamination water could be cleaned to the extent that it could be discharged to normal drainage. Resultant solid wastes were packaged in standard flexible containers, labelled and stored at the remediation site (temporary storage until central interim storage becomes available). The designs of such temporary storage facilities were tailored to available sites, but all designs included measures to ensure mechanical stability (e.g., filling void spaces between containers with sand, graded cover with soil) and prevent releases to groundwater (impermeable base and cap, gravity flow drainage including radiation monitors and catch tanks). Storage site monitoring was also needed to check that storage structures would not be perturbed by external events that could include typhoons, heavy snowfalls, freeze/thaw cycles and earthquakes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Atomic layer deposition of alternative glass microchannel plates

The technique of atomic layer deposition (ALD) has enabled the development of alternative glass microchannel plates (MCPs) with independently tunable resistive and emissive layers, resulting in excellent thickness uniformity across the large area (20 × 20 cm), high aspect ratio (60:1 L/d) glass substrates. Furthermore, the use of ALD to deposit functional layers allows the optimal substrate material to be selected, such as borosilicate glass, which has many benefits compared to the lead-oxide glass used in conventional MCPs, including increased stability and lifetime, low background noise, mechanical robustness, and larger area (at present up to 400 cm{sup 2}). Resistively stable, high gain MCPs are demonstrated due to the deposition of uniform ALD resistive and emissive layers on alternative glass microcapillary substrates. The MCP performance characteristics reported include increased stability and lifetime, low background noise (0.04 events cm{sup −2} s{sup −1}), and low gain variation (±5%)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of the microcalorimeter and anticoincidence detector for the Line Emission Mapper x-ray probe

The Line Emission Mapper (LEM) is an x-ray probe mission concept that is designed to provide unprecedented insight into the physics of galaxy formation, including stellar and black-hole feedback and flows of baryonic matter into and out of galaxies. LEM incorporates a light-weight x-ray optic with a large-format microcalorimeter array. The LEM detector utilizes a 14k pixel array of transition-edge sensors (TESs) that will provide <2.5 eV spectral resolution over the energy range 0.2 to 2 keV, along with a field-of-view of 30 arcmin. The microcalorimeter array and readout builds upon the technology developed for the European Space Agency’s (ESA’s) Athena/x-ray Integral Field Unit. Here, we present a detailed overview of the base- line microcalorimeter design, its performance characteristics, including a detailed energy resolution budget and the expected count-rate capability. In addition, we outline the current status and plan for continued technology maturation. Behind the LEM array sits a high-efficiency TES-based anticoincidence (antico) detector that will reject cosmic-ray background events. We will briefly describe the design of the antico and plan for continued development.

47 OTHER INSTRUMENTATION↗

Solid State Streak Camera Prototype Electronic Performance Testing and Characterization

Streak Cameras are an essential diagnostic tool used in shock physics and high energy density physics experiments. Such experiments require well calibrated temporally resolved diagnostics for studying events that occur in the nanosecond to microsecond time scales. Although streak cameras are among the most common detectors used within the high energy density physics community, they require frequent calibration and typically lack reproducibility in the fine detail. A solid state device with similar temporal performance characteristics could provide several advantages to current streak camera systems by utilizing discrete spatial resolution set by the sensor diodes. National Security Technologies (NSTec) has built a multi-channel solid state streak camera (SSSC) prototype, in collaboration with Sandia National Laboratories, as part of an ongoing project to develop the technology to a level competitive with analog streak cameras. The device concept and results from electronic testing of our first prototypes will be discussed in this manuscript. These measurements will be used as a base for future SSSC development projects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-638: Evaluation and Comparison of Landauer Microstar (OSLD) Readers

Purpose: To evaluate and compare characteristic performance of a new Landauer nanodot Reader with the previous model. Methods: In order to calibrate and test the reader, a set of nanodots were irradiated using a Varian Truebeam Linac. Solid water slabs and bolus were used in the process of irradiation. Calibration sets of nanodots were irradiated for radiation dose ranges: 0 to 10 and 20 to 1000 cGy, using 6MV photons. Additionally, three sets of nanodots were each irradiated using 6MV, 10MV and 15MV beams. For each beam energy, and selected dose in the range of 3 to 1000 cGy, a pair of nanodots was irradiated and three readings were obtained with both readers. Results: The analysis shows that for 3 photon beam energies and selected ranges of dose, the calculated absorbed dose agrees well with the expected value. The results illustrate that the new Microstar II reader is a highly consistent system and that the repeated readings provide results with a reasonably small standard deviation. For all practical purposes, the response of system is linear for all radiation beam energies. Conclusion: The Microstar II nanodot reader is consistent, accurate, and reliable. The new hardware design and corresponding software contain several advantages over the previous model. The automatic repeat reading mechanism, that helps improve reproducibility and reduce processing time, and the smaller unit size that renders ease of transport, are two of such features. Present study shows that for high dose ranges a polynomial calibration equation provides more consistent results. A 3rd order polynomial calibration curve was used to analyze the readings of dosimeters exposed to high dose range radiation. It was observed that the results show less error compared to those calculated by using linear calibration curves, as provided by Landauer system software for all dose ranges.

60 APPLIED LIFE SCIENCES↗

SU-E-QI-15: Single Point Dosimetry by Means of Cerenkov Radiation Energy Transfer (CRET)

Purpose: Cerenkov light is generated when a charged particles with energy greater then 250 keV, moves faster than the speed of light in a given medium. Both x-ray photons and electrons produce optical Cerenkov photons during the static megavoltage linear accelerator (LINAC) operational mode. Recently, Cerenkov radiation gained considerable interest as possible candidate as a new imaging modality. Optical signals generated by Cerenkov radiation may act as a surrogate for the absorbed superficial radiation dose. We demonstrated a novel single point dosimetry method for megavoltage photon and electron therapy utilizing down conversion of Cerenkov photons. Methods: The custom build signal characterization system was used: a sample holder (probe) with adjacent light tight compartments was connected via fiber-optic cables to a photon counting photomultiplier tube (PMT). One compartment contains a medium only while the other contains medium and red-shifting nano-particles (Q-dots, nanoclusters). By taking the difference between the two signals (Cerenkov photons and CRET photons) we obtain a measure of the down-converted light, which we expect to be proportional to dose as measured with an adjacent ion chamber. Experimental results are compared to Monte Carlo simulations performed using the GEANT4 code. Results: The signal correlation between CR signal, CRET readings and dose produced by LINAC at a single point were investigated. The experimental results were compared with simulations. The dose linearity, signal to noise ratio and dose rate dependence were tested with custom build CRET based probe. Conclusion: Performance characteristics of the proposed single point CRET based probe were evaluated. The direct use of the induced Cerenkov emission and CRET in an irradiated single point volume as an indirect surrogate for the imparted dose was investigated. We conclude that CRET is a promising optical based dosimetry method that offers advantages over those already proposed.

60 APPLIED LIFE SCIENCES↗

Verification of a novel method for tube voltage constancy measurement of orthovoltage x-ray irradiators

Purpose: For orthovoltage x-ray irradiators, the tube voltage is one of the most fundamental system parameters as this directly relates to the dosimetry in radiation biology studies; however, to the best of our knowledge, there is no commercial portable quality assurance (QA) tool to directly test the constancy of the tube voltage greater than 160 kV. The purpose of this study is to establish the Beam Quality Index (BQI), a quantity strongly correlated to the tube voltage, as an alternative parameter for the verification of the tube voltage as part of the QA program of orthovoltage x-ray irradiators. Methods: A multipurpose QA meter and its associated data acquisition software were used to customize the measurement parameters to measure the BQI and collect its time-plot. BQI measurements were performed at 320 kV with four filtration levels on three orthovoltage x-ray irradiators of the same model, one of which had been recently energy-calibrated at the factory. Results: For each of the four filtration levels, the measured BQI values were in good agreement (<5%) between the three irradiators. BQI showed filtration-specificity, possibly due to the difference in beam quality. Conclusions: The BQI has been verified as a feasible alternative for monitoring the constancy of the tube voltage for orthovoltage irradiators. The time-plot of BQI offers information on the behavior of beam energy at different phases of the irradiation time line. In addition, this would provide power supply performance characteristics from initial ramp-up to plateau, and finally, the sharp drop-off at the end of the exposure.

60 APPLIED LIFE SCIENCES↗

On the Strong Scaling of the Spectral Element Solver Nek5000 on Petascale Systems. In: EASC '16 Proceedings of the Exascale Applications and Software Conference 2016, Article No. 5

The present work is targeted at performing a strong scaling study of the high-order spectral element fluid dynamics solver Nek5000. Prior studies such as [5] indicated a recommendable metric for strong scalability from a theoretical viewpoint, which we test here extensively on three parallel machines with different performance characteristics and interconnect networks, namely Mira (IBM Blue Gene/Q), Beskow (Cray XC40) and Titan (Cray XK7). The test cases considered for the simulations correspond to a turbulent flow in a straight pipe at four different friction Reynolds numbers Reτ = 180, 360, 550 and 1000. Considering the linear model for parallel communication we quantify the machine characteristics in order to better assess the scaling behaviors of the code. Subsequently sampling and profiling tools are used to measure the computation and communication times over a large range of compute cores. We also study the effect of the two coarse grid solvers XXT and AMG on the computational time. Super-linear scaling due to a reduction in cache misses is observed on each computer. The strong scaling limit is attained for roughly 5000-10,000 degrees of freedom per core on Mira, 30,000 - 50,0000 on Beskow, with only a small impact of the problem size for both machines, and ranges between 10,000 and 220,000 depending on the problem size on Titan. This work aims at being a reference for Nek5000 users and also serves as a basis for potential issues to address as the community heads towards exascale supercomputers.

Offermans, Nicolas↗

diBELLA: Distributed Long Read to Long Read Alignment

© 2019 ACM. We present a parallel algorithm and scalable implementation for genome analysis, specifically the problem of finding overlaps and alignments for data from "third generation" long read sequencers [29]. While long sequences of DNA offer enormous advantages for biological analysis and insight, current long read sequencing instruments have high error rates and therefore require different approaches to analysis than their short read counterparts. Our work focuses on an efficient distributed-memory parallelization of an accurate single-node algorithm for overlapping and aligning long reads. We achieve scalability of this irregular algorithm by addressing the competing issues of increasing parallelism, minimizing communication, constraining the memory footprint, and ensuring good load balance. The resulting application, diBELLA, is the first distributed memory overlapper and aligner specifically designed for long reads and parallel scalability. We describe and present analyses for high level design trade-offs and conduct an extensive empirical analysis that compares performance characteristics across state-of-the-art HPC systems as well as a commercial cloud architectures, highlighting the advantages of state-of-the-art network technologies.

Ellis, Marquita↗

CommBench: Micro-Benchmarking Hierarchical Networks with Multi-GPU, Multi-NIC Nodes

Modern high-performance computing systems have multiple GPUs and network interface cards (NICs) per node. The resulting network architectures have multilevel hierarchies of subnetworks with different interconnect and software technologies. These systems offer multiple vendor-provided communication capabilities and library implementations (IPC, MPI, NCCL, RCCL, OneCCL) with APIs providing varying levels of performance across the different levels. Understanding this performance is currently difficult because of the wide range of architectures and programming models (CUDA, HIP, OneAPI). We present CommBench, a library with cross-system portability and a high-level API that enables developers to easily build microbenchmarks relevant to their use cases and gain insight into the performance (bandwidth & latency) of multiple implementation libraries on different networks. We demonstrate CommBench with three sets of microbenchmarks that profile the performance of six systems. Our experimental results reveal the effect of multiple NICs on optimizing the bandwidth across nodes and also present the performance characteristics of four available communication libraries within and across nodes of NVIDIA, AMD, and Intel GPU networks.

Hidayetoglu, Mert↗