Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optical computing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

A polarizer for vacuum ultraviolet

An MgF2 double Rochon prism, useful as a polarizer or analyzer in wavelengths longer than 1300A is described. Measurements of MgF2 transmission and of polarizer angular beam deviation from 1150 to 2900A are presented. The prism is comprised of 2.25 mm, MgF2 depolarizers, optically contacted. At normal incidence, a 4% transmission gain was measured from 6000 to 2200A, compared with air spaced elements. One depolarizer was vibrated to 40 g from 20 to 3500 Hz without deterioration in optical contact. Transmissions below 1400A are not good. In thin samples, surface loss is twice absorption loss in the range 1150 to 1500A. Refraction indices and a computer ray trace were used in processing photographic beam divergence data. If care is taken to remedy scattering effects, the prism is an efficient on-axis polarizer in the 1300 to 3000A range.

Steinmetz, D. L.↗

LANES 1 Users' Guide

This document is intended for users of the Local Area Network Extensible Simulator, version I. This simulator models the performance of a Fiber Optic network under a variety of loading conditions and network characteristics. The options available to the user for defining the network conditions are described in this document. Computer hardware and software requirements are also defined.

Jordan, J.↗

Steady state cooling flow models for normal elliptical galaxies

An extensive grid of steady state cooling flow models for the hot gas in elliptical galaxies is calculated. The effects of allowing inflow of surrounding gas and varying the supernova heating rate, the mass distribution of the galaxy, the rate of stellar mass loss, and the outer boundary pressure are studied. The X-ray luminosities, spectra, and surface brightness profiles of the galaxies are computed. In all of the models, the gas density varies approximately as r exp -3/2. In the models with heavy halos, the X-ray and optical surface brightnesses are nearly proportional to one another within individual galaxies, and the temperature profiles are roughly isothermal.

Sarazin, Craig L.↗

Emittance bounds for transient radiative cooling of a scattering rectangular region

Transient cooling was analyzed for a two-dimensional gray rectangular region that emits, absorbs, and isotropically scatters radiation. The region, initially at uniform temperature, is placed in surroundings at a much lower temperature. The cooling analysis yields two simultaneous equations for the transient temperature and scattering source function distributions. The region starts to cool with the medium at uniform temperature. For this condition, the local emittance around the perimeter was obtained by a numerical solution of the radiative equations, and the rate of heat loss from the entire medium was evaluated. As cooling continues, the emissive ability decreases because of the lower temperatures in the outer regions of the rectangle. Based on some previous work, a lower limit for the transient overall emittance was found by obtaining a similarity solution. For some ranges of optical thickness and scattering albedo, the lower limit is only a small amount below the initial emittance. For these conditions, the initial emittance can be used to compute the entire transient resulting in a considerable simplification.

Siegel, Robert↗

Bacteriorhodopsin Film For Processing SAR Signals

"Instant" photographic film based on semisynthetic retinal pigment bacteriorhodopsin proposed for optical processing of synthetic-aperture-radar (SAR) signals. Input image recorded on film by laser operating at writing wavelength of bacteriorhodopsin, and output image recorded on computer by standard frame-grabber. Because it requires no chemical development, enables processing in nearly real time. Fast response and high resolution well suited for application. Film reusable, with concomitant reduction in cost of SAR processing.

Yu, Jeffrey W.↗

Effect of particle size in composite materials on radiative properties

A numerical model for the radiative properties of a composite material composed of ceramic oxide fibers and particles was developed and used to determine the effect of the size parameters of the two components. Results include the computed phase functions for the zirconia and silica composite materials, showing the location and strength of the strong forward-scattering peak. The phase function and the optical properties of the composite are strongly influenced by the particle size parameter through the fiber or particle diameter and the wavelength, the material, and the mixture fraction.

Lee, Siu-Chun↗

Low-Flow-Rate Dry-Powder Feeder

Apparatus feeds small, precise flow of dry powder through laser beam of optical analyzer, measuring patterns of light created by forward scattering (Fraunhofer diffraction) of laser beam from powder particles. From measurement, statistical distribution of sizes of powder particles computed. Developed for analyzing particle-size distributions of solid-propellant powders. Also adapted to use in pharmaceutical industry, in manufacture of metal powder, and in other applications in which particle-size distributions of materials used to control rates of chemical reactions and/or physical characteristics of processes.

Ramsey, Keith E.↗

Realistic NLTE Radiative Transfer for Modeling Stellar Winds

This NASA grant supported the development of codes to solve the non-LTE multi-level spherical radiative transfer problem in the presence of velocity fields. Much of this work was done in collaboration with Graham Harper (CASA, University of Colorado). These codes were developed for application to the cool, low-velocity winds of evolved late-type stars. Particular emphasis was placed on modeling the wind of lambda Velorum (K4 lb), the brightest K supergiant in the sky, based on extensive observations of the ultraviolet spectrum with the HST/GHRS from GO program 5307. Several solution techniques were examined, including the Eddington factor Approach described in detail by Bennett & Harper (1997). An Eddington factor variant of Harper's S-MULTI code (Harper 1994) for stationary atmospheres was developed and implemented, although full convergence was not realized. The ratio of wind terminal velocity to turbulent velocity is large (approx. 0.3-0.5) in these cool star winds so this assumption of stationarity provides reasonable starting models. Final models, incorporating specified wind laws, were converged using the comoving CRD S-MULTI code. Details of the solution procedure were published by Bennett & Harper (1997). Our analysis of the wind of lambda Vel, based on wind absorption superimposed on chromospheric emission lines in the ultraviolet, can be found in Carpenter et al. (1999). In this paper, we compare observed wind absorption features to an exact CRD calculation in the comoving frame, and also to a much quicker, but approximate, method using the SEI (Sobolev with Exact Integration) code of Lamers, Cerruti-Sola, & Perinotto (1987). Carpenter et al. (1999) provide detailed comparisons of the exact CRD and approximate SEI results and discuss when SEI is adequate to use for computing wind line profiles. Unfortunately, the observational material is insufficient to unambiguously determine the wind acceleration law for lambda Vel. Relatively few unblended Fe II lines of optical depth sensitive to the wind acceleration region are present in the existing HST/GHRS data set. Most of the Fe II lines are either too optically thick (resulting in a board, black wind absorption profile) or too optically thin (resulting in no wind absorption feature present). Also, most of the ultraviolet spectra obtained from HST GO-5307 was at medium resolution (R approx. 40,000, corresponding to a velocity resolution of 7.5 km/s). This is simply inadequate to resolve the turbulence in the outer wind; a key parameter in theoretical wind models. We can now say that an unambiguous determination of the wind velocity law in lambda Vel will require complete coverage of the ultraviolet spectrum at high dispersion (R approx. 10(exp 5), or 3 km/s). This is now feasible usin, the STIS echelle spectrograph on-board HST.

Bennett, Philip D.↗

Liquid Crystal-Based Beam Steering Device Development for NASA Applications

The NASA Computing, Information and Communications Technology (CICT) Program is supporting the development of liquid crystal-based beam steering devices. The device would use inexpensive, light-weight, optical components, and it would have the following capabilities: electronic beam scanning to angles above 1 milliradian, and submicroradian beam pointing accuracy. In order to correct for the imperfections resulting from the space-deployable optics, the technique of wave-front correction would be implemented. Hence, the output beam quality would be maintained. The potential applications could include satellite tracking, near-Earth inter-satellite communications, deep-space communications, and optical phased array systems. The status of the beam steering device development based on the liquid crystal technology and its relationship to prospective NASA mission scenarios will be described.

Pouch, John↗

Microbe Detector

The AutoMicrobic System (AMS) represents years of intensive research and development by McDonnell Douglas Corp. that originated with a NASA study aimed at development of a fully automated microbial detection and identification system for spacecraft use. A urine specimen is placed into the system, where it is subjected to different freeze-dried microbe nutrients for the nine most common pathogens. An electro-optical scanner studies each specimen once an hour through a 4-to-13 hour cycle, operating automatically. Changes in cell growths on each culture are monitored by computer. The presence of pathogens is indicated when growth reaches a predetermined level. The system also enumerates the pathogens and specifies the type. Developed initially to handle urine testing, AMS soon is expected to allow analyses of blood, spinal fluid, and other body fluids. An additional capability under development is "susceptibility testing," or the determination of which microbe-killing agents-such as penicillin or other antibiotics-would be most effective in eliminating the pathogens. The whole process of detecting, identifying, and enumerating the pathogens and determining susceptibility is accomplished in less half the time required for the manual procedure. The AMS minimizes human error, reduces technician time , and increases laboratory output.

Source record↗

Benchtop Detection of Proteins

A process, and a benchtop-scale apparatus for implementing the process, have been developed to detect proteins associated with specific microbes in water. The process and apparatus may also be useful for detection of proteins in other, more complex liquids. There may be numerous potential applications, including monitoring lakes and streams for contamination, testing of blood and other bodily fluids in medical laboratories, and testing for microbial contamination of liquids in restaurants and industrial food-processing facilities. A sample can be prepared and analyzed by use of this process and apparatus within minutes, whereas an equivalent analysis performed by use of other processes and equipment can often take hours to days. The process begins with the conjugation of near-infrared-fluorescent dyes to antibodies that are specific to a particular protein. Initially, the research has focused on using near-infrared dyes to detect antigens or associated proteins in solution, which has proven successful vs. microbial cells, and streamlining the technique in use for surface protein detection on microbes would theoretically render similar results. However, it is noted that additional work is needed to transition protein-based techniques to microbial cell detection. Consequently, multiple such dye/antibody pairs could be prepared to enable detection of multiple selected microbial species, using a different dye for each species. When excited by near-infrared light of a suitable wavelength, each dye fluoresces at a unique longer wavelength that differs from those of the other dyes, enabling discrimination among the various species. In initial tests, the dye/antibody pairs are mixed into a solution suspected of containing the selected proteins, causing the binding of the dye/antibody pairs to such suspect proteins that may be present. The solution is then run through a microcentrifuge that includes a membrane that acts as a filter in that it retains the dye/antibody/protein complexes while allowing any remaining unbound dye/antibody pairs to flow away. The retained dye/antibody/protein complexes are transferred to a cuvette, wherein they are irradiated with light from a miniature near-infrared laser delivered via a fiber-optic cable. The resulting fluorescence from the dye(s) is measured by use of a miniature spectrometer, the output of which is digitized, then analyzed by laptop computer. The software running in the computer identifies the protein species by the wavelengths of their spectral peaks and determines the amounts of the proteins, and thus, one day, microbes of the various species from the intensities of the peaks. The abovementioned removal of the unbound dye/antibody pairs during centrifugation prevents false positive readings. The process proves successful in detecting proteins in solution and thus can now be employed for use in microbe detection.

Scardelletti, Maximilian C.↗

Light Scattering by Wavelength-Sized Particles "Dusted" with Subwavelength-Sized Grains

The numerically exact superposition T-matrix method is used to compute the scattering cross sections and the Stokes scattering matrix for polydisperse spherical particles covered with a large number of much smaller grains. We show that the optical effect of the presence of microscopic dust on the surfaces of wavelength-sized, weakly absorbing particles is much less significant than that of a major overall asphericity of the particle shape.

Mishchenko, Michael I.↗

Correlated Changes in Retinal Thickness and Visuomotor Function in Asymptomatic Plaquenil Toxicity Patients

We have previously shown that a 5-minute eye-movement test can capture a number of largely independent “oculometric” parameters of human visual/visuomotor function (Liston & Stone, 2014). This test has been successfully used to characterize mild neural impairment due to traumatic brain injury, sleep and circadian disruption, and alcohol consumption (Liston et al., 2017; Stone et al, 2019; Tyson et al, 2021). Here, we extend this approach to study patients at risk of progressive posterior-segment illness to see how oculometrics relate to standard clinical ophthalmological measures. Five female patients (<20:40 BCVA, 34-60 years old) undergoing hydroxychloroquine treatment (2-7mg/kg/day for 10-23 years for rheumatologic illness) have participated thus far. Under monocular viewing conditions in randomized order, they tracked a moving spot undergoing radial step-ramp motion in one of 90 randomized directions, at one of 5 randomized speeds, starting at random times (for details, see Stone et al, 2019). We computed nine independent oculometrics (latency, initial acceleration, steady-state gain, proportion smooth, saccadic rate, saccadic amplitude, direction noise, speed responsiveness, and speed noise). Spectral-domain optical coherence tomography (Zeiss, Dublin, CA) was used to measure the average thickness of the nine Early Treatment Diabetic Retinopathy Study macular sectors from the internal limiting membrane to the retinal pigmented epithelium. We used Pearson’s correlation between retinal thickness and our oculometrics with t-statistics to test separate one-sided hypotheses across 10 retinae. Our preliminary analysis found significant changes in several different aspects of visuomotor performance. Most notably, latency increased, initial acceleration decreased, and steady-state pursuit gain decreased as retinal thickness decreased (r2 = 0.364, 0.579, and 0.692; one-tailed P = 0.032, 0.005, and 0.001, respectively). Speed responsiveness appeared to decrease, but this effect was marginal for our current sample (r2 = 0.253, P = 0.069). Lastly, direction discrimination and saccadic behavior appeared unchanged. We conclude that oculometrics may provide sensitive measures of changes in retinal thickness. More importantly, oculometrics have the potential to detect impairment before it becomes evident with standard clinical imaging tools, while also providing insight into the behavioral implications of any resulting deficits in visual/visuomotor function.

eye movements↗

Multiscale and Multifidelity Modeling of a 3D Woven Composite Thermal Protection System

Complex three-dimensional (3D) woven composites have been considered by multiple NASA projects in recent years as a means of offering improved mechanical and thermal performance over traditional laminated composite systems. Parallel efforts have focused on developing simulation capabilities for these systems, which have traditionally and heavily relied on experimental testing to evaluate composite performance. One system is the Heatshield for Extreme Entry Environment Technology (HEEET), which is being considered for the thermal protection system on reentry spacecraft. Optical microscopy was used to characterize the blended carbon and phenolic fiber tows. A section of HEEET insulation layer was imaged with high-resolution micro-computed tomography (microCT) and segmented to separate individual tows, porous matrix, and voids. These data were used to develop multiscale thermomechanical computational models within the NASA Multiscale Analysis Tool (NASMAT). Two NASMAT modeling approaches were considered to capture the details of the 3D woven architecture: a coarse model appropriate for inclusion in multiscale structural analyses and a high-fidelity model created by downsampling the microCT data. Both elastic and thermal properties were computed and compared. The feasibility and challenges associated with modeling complex, hybrid 3D woven composites were also addressed.

NASMAT↗

Submillimeter Laboratory Investigations: Spectroscopy and Collisions

Currently, millimeter-wave and submillimeter-wave spectroscopy is conducted in our laboratory on several different types of spectrometers. Our standard spectrometer utilizes the output of a phase-locked klystron operating in the 40-60 GHz region, which is sent into a crossed-waveguide harmonic generator, or "multiplier". The high frequency millimeter-and submillimeter-wave radiation is transmitted via quasi-optical techniques through an absorption cell and then onto a detector, which is either an InSb hot electron bolometer cooled to 1.4 K or a Si bolometer cooled to 0.3 K. The detector response is sent to a computer for measurement and analysis. The frequency range produced and detected in this manner goes from 80 GHz to upwards of 1 THz. Spectra are normally taken with source modulation, with line frequencies typically measured to an accuracy of 50-100 kHz. Higher accuracy is available when needed. Recently, we developed a new, broad-band spectrometer in our laboratory based on a free-running backward wave oscillator (BWO) of Russian manufacture as the primary source of radiation. The so-called FASSST (fast-scan submillimeter spectroscopic technique) system uses fast-scan and optical calibration methods rather than the traditional locking techniques. The output power from the BWO is split such that 90% goes into the absorption cell while 10% is coupled to a 40-meter Fabry-Perot cavity, which yields fringe? for frequency measurement. Results from this spectrometer on the spectrum of nitric acid (HNO3) show that 100 GHz of spectral data can be obtained in 5 seconds with a measurement accuracy of 50 kHz. Currently, the frequency range of the FASSST system in our laboratory is roughly 100-700 GHz.

Herbst, Eric↗

Hubble Space Telescope COSTAR asphere verification with a modified computer-generated hologram interferometer

To correct for the spherical aberration in the Hubble Space Telescope primary mirror, five anamorphic aspheric mirrors representing correction for three scientific instruments have been fabricated as part of the development of the corrective-optics space telescope axial-replacement instrument (COSTAR). During the acceptance tests of these mirrors at the vendor, a quick and simple method for verifying the asphere surface figure was developed. The technique has been used on three of the aspheres relating to the three instrument prescriptions. Results indicate that the three aspheres are correct to the limited accuracy expected of this test.

Feinberg, L.↗

The Atacama Cosmology Telescope: High-Resolution Sunyaev-Zel'dovich Array Observations of ACT SZE-Selected Clusters from the Equatorial Strip

We present follow-up observations with the Sunyaev-Zel'dovich Array (SZA) of optically-confirmed galaxy clusters found in the equatorial survey region of the Atacama Cosmology Telescope (ACT): ACT-CL J0022-0036, ACT-CL J2051+0057, and ACT-CL J2337+0016. ACT-CL J0022-0036 is a newly-discovered, massive (10(exp 15) Msun), high-redshift (z=0.81) cluster revealed by ACT through the Sunyaev-Zel'dovich effect (SZE). Deep, targeted observations with the SZA allow us to probe a broader range of cluster spatial scales, better disentangle cluster decrements from radio point source emission, and derive more robust integrated SZE flux and mass estimates than we can with ACT data alone. For the two clusters we detect with the SZA we compute integrated SZE signal and derive masses from the SZA data only. ACT-CL J2337+0016, also known as Abell 2631, has archival Chandra data that allow an additional X-ray-based mass estimate. Optical richness is also used to estimate cluster masses and shows good agreement with the SZE and X-ray-based estimates. Based on the point sources detected by the SZA in these three cluster fields and an extrapolation to ACT's frequency, we estimate that point sources could be contaminating the SZE decrement at the less than = 20% level for some fraction of clusters.

Reese, Erik D.↗

Reducing video frame rate increases remote optimal focus time

Twelve observers made best optical focus adjustments to a microscope whose high-resolution pattern was video monitored and displayed first on a National Television System Committee (NTSC) analog color monitor and second on a digitally compressed computer monitor screen at frame rates ranging (in six steps) from 1.5 to 30 frames per second (fps). This was done to determine whether reducing the frame rate affects the image focus. Reducing frame rate has been shown to be an effective and acceptable means of reducing transmission bandwidth of dynamic video imagery sent from Space Station Freedom (SSF) to ground scientists. Three responses were recorded per trial: time to complete the focus adjustment, number of changes of focus direction, and subjective rating of final image quality. It was found that: the average time to complete the focus setting increases from 4.5 sec at 30 fps to 7.9 sec at 1.5 fps (statistical probability = 1.2 x 10(exp -7)); there is no significant difference in the number of changes in the direction of focus adjustment across these frame rates; and there is no significant change in subjectively determined final image quality across these frame rates. These data can be used to help pre-plan future remote optical-focus operations on SSF.

Haines, Richard F.↗