Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Organic liquid scintillation detectors for on-the-fly neutron/gamma alarming and radionuclide identification in a pedestrian radiation portal monitor

Here, we present new experimental results from a radiation portal monitor based on the use of organic liquid scintillators. The system was tested as part of a 3 He-free radiation portal monitor testing campaign at the European Commission’s Joint Research Centre in Ispra, Italy, in February 2014. The radiation portal monitor was subjected to a wide range of test conditions described in ANSI N42.35, including a variety of gamma-ray sources and a 20,000 n/s 252 Cf source. A false alarm test tested whether radiation portal monitors ever alarmed in the presence of only natural background. The University of Michigan Detection for Nuclear Nonproliferation Group’s system triggered zero false alarms in 2739 trials. It consistently alarmed on a variety of gamma-ray sources travelling at 1.2 m/s at a 70 cm source to detector distance. The neutron source was detected at speeds up to 3 m/s and in configurations with up to 8 cm of high density polyethylene shielding. The success of on-the-fly radionuclide identification varied with the gamma-ray source measured as well as with which of two radionuclide identification methods was used. Both methods used a least squares comparison between the measured pulse height distributions to library spectra to pick the best match. The methods varied in how the pulse height distributions were modified prior to the least squares comparison. Correct identification rates were as high as 100% for highly enriched uranium, but as low as 50% for 241 Am. Lastly, both radionuclide identification algorithms produced mixed results, but the concept of using liquid scintillation detectors for gamma-ray and neutron alarming in radiation portal monitor was validated.

3He replacement technology↗

Exploratory Research on the Development of Novel Ce3+-Activated Phosphate Glass Scintillators

Abstract We report the discovery of a new family of Ce3+-activated phosphate glass scintillators that can be formed either with or without the addition of 6Li, for neutron or X-ray/gamma-ray radiation detection, respectively. Trivalent cerium can be efficiently introduced into these phosphate glasses in surprisingly high concentrations in the form of anhydrous cerium tri-chloride. Additionally, these glasses can be melted and poured at the relatively low temperatures of 1000 1050 oC (i.e., substantially lower than silicate glasses), and to retain the cerium in the trivalent state it is not necessary to maintain highly reducing conditions during the synthesis process. The family of alkaline-earth-alkali phosphate glasses investigated here represents a system with two dissimilar cations - thereby offering a large range of potential compositional variations, substitutions, and combinations. In order to alter the scintillator characteristics, we have explored part of that compositional space by studying Ca-Na, Ca-Li, Ca-Cs, Ca-Rb, Ca-K and Ca-Ba-Na phosphate glasses, as well as various co-doping and post-synthesis thermal processing schemes. A series of experiments under x ray, gamma ray, and neutron excitations was carried out. The broad, peaking at about 355 nm,, UV scintillation of these glasses is well suited for applications that use common photomultipliers with bi-alkali photo-cathodes. Pulse shape measurements show that the primary component of the scintillation in most of these glasses corresponds to 75 90 % of the emitted photons, and it decays with a time constant of 30 to 40 ns, which classifies these materials as reasonably fast scintillators. Although the gamma-induced light yield of these new scintillating phosphate glasses is, thus far, only about 30 % of that of commercial GS20 silicate glass, due to the generally faster scintillation, the initial amplitude of the scintillation pulse of these glasses is close to that of the above-mentioned GS20 scintillator.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Device for Detection of Explosives, Nuclear and Other Hazardous Materials in Luggage and Cargo Containers

Device for detection of explosives, radioactive and heavily shielded nuclear materials in luggage and cargo containers based on Nanosecond Neutron Analysis/Associated Particles Technique (NNA/APT) is under construction. Detection module consists of a small neutron generator with built-in position-sensitive detector of associated alpha-particles, and several scintillator-based gamma-ray detectors. Explosives and other hazardous chemicals are detected by analyzing secondary high-energy gamma-rays from reactions of fast neutrons with materials inside a container. The same gamma-ray detectors are used to detect unshielded radioactive and nuclear materials. An array of several neutron detectors is used to detect fast neutrons from induced fission of nuclear materials. Coincidence and timing analysis allows one to discriminate between fission neutrons and scattered probing neutrons. Mathematical modeling by MCNP5 and MCNP-PoliMi codes was used to estimate the sensitivity of the device and its optimal configuration. Comparison of the features of three gamma detector types--based on BGO, NaI and LaBr{sub 3} crystals is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of 149 Sm Capture and Total Cross Sections for Burnup Credit Applications [Slides]

This presentation highlights how capture and transmission measurements were performed with the DANCE (Detector for Advanced Neutron Capture Experiments) instrument with capture data from 8 eV – 1 keV, and DICER (Device for Indirect Capture Experiments on Radionuclides) instruments with transmission data from 1meV – 1 keV. There were additional measurements of 147 Sm which had contaminant in the samples, 3.4 eV strong resonance, interesting abnormalities. The data analysis is complete and the R-Matrix analysis almost (90%) complete.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved Fission Neutron Data Base for Active Interrogation of Actinides

This project will develop an innovative neutron detection system for active interrogation measurements. Many active interrogation methods to detect fissionable material are based on the detection of neutrons from fission induced by fast neutrons or high-energy gamma rays. The energy spectrum of the fission neutrons provides data to identify the fissionable isotopes and materials such as shielding between the fissionable material and the detector. The proposed path for the project is as follows. First, the team will develop new neutron detection systems and algorithms by Monte Carlo simulations and bench-top experiments. Next, they will characterize and calibrate detection systems both with monoenergetic and white neutron sources. Finally, high-fidelity measurements of neutron emission from fissions induced by fast neutrons will be performed. Several existing fission chambers containing U-235, Pu-239, U-238, or Th-232 will be used to measure the neutron-induced fission neutron emission spectra. The challenge for making confident measurements is the detection of neutrons in the energy ranges of 0.01 – 1 MeV and above 8 MeV, regions where the basic data on the neutron energy spectrum emitted from fission is least well known. In addition, improvements in the specificity of neutron detectors are required throughout the complete energy range: they must be able to clearly distinguish neutrons from other radiations, in particular gamma rays and cosmic rays. The team believes that all of these challenges can be addressed successfully with emerging technologies under development by this collaboration. In particular, the collaboration will address the area of fission neutron emission spectra for isotopes of interest in the advanced fuel cycle initiative (AFCI).

Pozzi, Sara A.↗

33 TeV pgun collisions, Single particles type, PARTICLE GUN generator: pgun_neutron_eta35

Single particle gun for detector studies: A particle gun with single neutrons. One neutron per event. 5000 events per file, 50 files per sample. Production at (x,y,z,t)=(0,0,0,0). N and antiN are alternated. Momentum is 1, 2, 4, 8, 16, 32, .. 2^n (n=0,15). The energy is included to the file name. Uniform distribution in Phi. Uniform distribution in the Eta (pseudorapidity) range [-3.5, 3.5].

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Diagnosing residual motion via the x-ray self emission from indirectly driven inertial confinement implosions

In an indirectly driven implosion, non-radial translational motion of the compressed fusion capsule is a signature of residual kinetic energy not coupled into the compressional heating of the target. A reduction in compression reduces the peak pressure and nuclear performance of the implosion. Measuring and reducing the residual motion of the implosion is therefore necessary to improve performance and isolate other effects that degrade performance. Using the gated x-ray diagnostic, the x-ray Bremsstrahlung emission from the compressed capsule is spatially and temporally resolved at x-ray energies of >8.7 keV, allowing for measurements of the residual velocity. Here details of the x-ray velocity measurement and fitting routine will be discussed and measurements will be compared to the velocities inferred from the neutron time of flight detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

239Pu(n, 2n) and 241Pu(n, 2n) surrogate cross section measurements using NeutronSTARS

The goal of this project was to develop a new approach to measuring (n,2n) reactions for isotopes of interest. We set out to measure the 239 Pu(n,2n) and 241 Pu(n,2n) cross sections by directly detecting the 2n neutrons that are emitted. With the goal of improving the 239 Pu(n,2n) cross section and to measure the 241 Pu(n,2n) cross section for the first time. To that end, we have constructed a new neutron-charged-particle detector array called NeutronSTARS. It has been described extensively in Casperson et al. [1] and in Akindele et al. [2]. We have used this new neutron-charged-particle array to measure the 241 Pu and 239 Pu fission neutron multiplicity as a function of equivalent incident-neutron energy from 100 keV to 20 MeV. We have made a preliminary determination of the 239 Pu(n,2n) and 241 Pu(n,2n) cross sections from the surrogate 240 Pu(α,α’2n) and 242 Pu(α,α’2n) reactions respectively. The experimental approach, detector array, data analysis, and results to date are summarized in the following sections.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Study of Nuclear Recoil Backgrounds in Dark Matter Detectors

Despite the great success of the Standard Model of particle physics, a preponderance of astrophysical evidence suggests that it cannot explain most of the matter in the universe. This so-called dark matter has eluded direct detection, though many theoretical extensions to the Standard Model predict the existence of particles with a mass on the $1-1000$ GeV scale that interact only via the weak nuclear force. Particles in this class are referred to as Weakly Interacting Massive Particles (WIMPs), and their high masses and low scattering cross sections make them viable dark matter candidates. The rarity of WIMP-nucleus interactions makes them challenging to detect: any background can mask the signal they produce. Background rejection is therefore a major problem in dark matter detection. Many experiments greatly reduce their backgrounds by employing techniques to reject electron recoils. However, nuclear recoil backgrounds, which produce signals similar to what we expect from WIMPs, remain problematic. There are two primary sources of such backgrounds: surface backgrounds and neutron recoils. Surface backgrounds result from radioactivity on the inner surfaces of the detector sending recoiling nuclei into the detector. These backgrounds can be removed with fiducial cuts, at some cost to the experiment's exposure. In this dissertation we briefly discuss a novel technique for rejecting these events based on signals they make in the wavelength shifter coating on the inner surfaces of some detectors. Neutron recoils result from neutrons scattering from nuclei in the detector. These backgrounds may produce a signal identical to what we expect from WIMPs and are extensively discussed here. We additionally present a new tool for calculating ($\alpha$, n)yields in various materials. We introduce the concept of a neutron veto system designed to shield against, measure, and provide an anti-coincidence veto signal for background neutrons. We discuss the research and development that informed the design of the DarkSide-50 boron-loaded liquid scintillator neutron veto. We describe the specific implementation of this veto system in DarkSide-50, including a description of its performance, and show that it can reject neutrons with a high enough e_ciency to allow DarkSide-50 to run background-free for three years.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of HELIOS/BIPR/PARCS/MCNP6 Computation Route for WWER RPV Neutron Fluence Analysis and Validation Against Ex-Vessel Detector Measurement Data

Here, a computational route was developed for precise calculation of fast neutron fluence on a WWER-type reactor pressure vessel (RPV). The method is based on the transfer of neutronics data from HELIOS-2 lattice calculations and nodal diffusion neutronics data (power, density, and temperature) from BIPR7.1 and PARCS 3.36/PATHS core calculations into a three-dimensional (pinwise axially distributed) fixed neutron source for modeling of transport of fast neutrons from the reactor core to the outer surface of the RPV using MCNP6.2. Validation of the proposed computational method was carried out based on comparative analysis of MCNP6.2-predicted and neutron dosimetry–measured reaction rates [ 54 Fe(n,p) 54 Мn, 93 Nb(n,n') 93 mNb, and 58 Ni(n,р) 58 Со] on the outer surface of the Armenian Nuclear Power Plant (ANPP) Unit 2 RPV. Validation revealed that the MCNP6.2-predicted fast neutron fluence results are very sensitive to the ENDF-B neutron data. Particularly, MCNP6.2 with ENDF/B-VIII.0 significantly underpredicts (20% to 30%) fast neutron fluence while using ENDF/B-VII.1 data overpredicts it. Adding revised beta-released evaluations of 54 Fe, 56 Fe, 57 Fe, and 16 O from the International Nuclear Data Evaluation Network (INDEN) to ENDF/B-VIII.0 allows one to obtain reasonable agreement with measurement results for all types of measured reaction rates.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sci—Fri PM: Dosimetry—02: A Nested Neutron Spectrometer to Measure Neutron Spectra in Radiotherapy

During high-energy radiotherapy treatments, neutrons are produced in the head of the linac through photonuclear interactions. This has been a concern for many years as photoneutrons contribute to the accepted, yet unwanted, out-of-field doses that pose an iatrogenic risk to patients and an occupational risk to personnel. Presently, in-room neutron measurements are difficult and time-consuming and have traditionally been carried out using Bonner spheres with activation foils and TLDs. In this work, a new detector, the Nested Neutron Spectrometer (NNS) is tested for use in radiotherapy bunkers. The NNS is designed for easy handling and is more practical than the traditional Bonner spheres. The NNS, operated in current mode, was used to measure the dose equivalent, average energy and energy spectrum at several positions in a radiotherapy bunker. The average energy and spectra were compared to Monte Carlo simulations while the dose equivalent was compared to bubble detector measurements. The average energies, as measured by the NNS and Monte Carlo simulations, differed by approximately 30% across the bunker. Measurements of the dose equivalent using the NNS and the bubble detectors agreed within 50% in the maze and less than 10% close to the linac head. Apart from some discrepancies at thermal energies, we also found reasonable agreement between NNS-measured and Monte Carlo-simulated spectra at a number of locations within our radiotherapy bunker. Our results demonstrate that the NNS is a suitable detector to be used in high dose-rate radiotherapy environments.

07 ISOTOPE AND RADIATION SOURCES↗

Novel Perovskite Semiconductors for the Detection of Special Nuclear Material

Special nuclear material (SNM) detection using portable, highly efficient detectors is of paramount importance to national security for treaty verification and nonproliferation monitoring. The most mature technology for neutron detection is the 3He proportional counter; however, despite its high efficiency and ubiquitous use, 3He detectors have significant drawbacks, including long absorption lengths, high voltage requirements, and dependence on the availability of 3 He. The goal of this project is to synthesize a novel, boron-based perovskite semiconductor crystals to create a more efficient and more portable neutron detector. This innovative material will lead to a significant decrease in power and size requirements with higher operating temperatures than other traditional solid-state detectors. Directly incorporating 10 B eliminates the need for a conversion layer and leads to high neutron absorption coefficients. In this seedling project, we successfully synthesized millimeter sized crystals using inverse temperature crystallization with sizes of 1.73 mm in length and 480 μm in thickness.

36 MATERIALS SCIENCE↗

Solid-State Neutron Multiplicity Counting System Using Commercial Off-the-Shelf Semiconductor Detectors

This work iterates on the first demonstration of a solid-state neutron multiplicity counting system developed at Lawrence Livermore National Laboratory by using commercial off-the-shelf detectors. The system was demonstrated to determine the mass of a californium-252 neutron source within 20% error requiring only one-hour measurement time with 20 cm 2 of active detector area.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ON DISCOVERING ELECTROMAGNETIC EMISSION FROM NEUTRON STAR MERGERS: THE EARLY YEARS OF TWO GRAVITATIONAL WAVE DETECTORS

We present the first simulation addressing the prospects of finding an electromagnetic (EM) counterpart to gravitational wave (GW) detections during the early years of only two advanced detectors. The perils of such a search may have appeared insurmountable when considering the coarse ring-shaped GW localizations spanning thousands of square degrees using time-of-arrival information alone. Leveraging the amplitude and phase information of the predicted GW signal narrows the localization to arcs with a median area of only a few hundred square degrees, thereby making an EM search tractable. Based on the locations and orientations of the two LIGO detectors, we find that the GW sensitivity is limited to only two of the four sky quadrants. Thus, the rates of GW events with two interferometers is only ≈40% of the rate with three interferometers of similar sensitivity. Another important implication of the sky quadrant bias is that EM observatories in North America and Southern Africa would be able to systematically respond to GW triggers several hours sooner than Russia and Chile. Given the larger sky areas and the relative proximity of detected mergers, 1 m class telescopes with very wide-field cameras are well-positioned for the challenge of finding an EM counterpart. Identification of the EM counterpart amidst the larger numbers of false positives further underscores the importance of building a comprehensive catalog of foreground stellar sources, background active galactic nucleus and potential host galaxies in the local universe. This initial study is based on a small sample of 17 detected mergers; future works will expand this sample.

79 ASTRONOMY AND ASTROPHYSICS↗

Spectral Shifting in Nondestructive Assay Instrumentation

This project involves spectrum tailoring research that endeavors to better distinguish energies of gamma rays using different spectral material thicknesses and determine neutron energies by coating detectors with various materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low Level Neutron Spectroscopy

Although the most sought-after hot plasma fusion reactions use deuterium-tritium due to its higher fusion cross-section, the deuteron-deuteron fusion reaction is also used and is suspected in Low Energy Nuclear Reactions (LENR). Although LENR reactions are largely aneutronic, the D(d,n)3He reaction produces a 2.45 MeV kinetic energy neutron. In the course of fusion experiments at NASA, ranging from bremsstrahlung photoneutron-initiated fusion to Pd/D co-deposition, we’ve made use of liquid and solid neutron scintillator spectrometers, bubble detectors and Solid State Nuclear Track Detectors (CR-39). We have observed the unfolded neutron energy spectrum from primary fusion and boosted fusion or stripped neutrons from photoneutron induced fusion. Despite an average deuteron energy of 64 keV, the peak unfolded neutron flux was only a few neutrons/minute. The major problem was the 10e14vgamma ray/neutrons/second flux ratio.

Neutron spectroscopy↗

Induced-Fission Imaging of Nuclear Material

This paper presents initial results from development of the induced-fission imaging technique, which can be used for the purpose of measuring or verifying the distribution of fissionable material in an unopened container. The technique is based on stimulating fissions in nuclear material with 14 MeV neutrons from an associated-particle deuterium-tritium (D-T) generator and counting the subsequent induced fast fission neutrons with an array of fast organic scintillation detectors. For each source neutron incident on the container, the neutron creation time and initial trajectory are known from detection of the associated alpha particle of the d + t → α + n reaction. Many induced fissions will lie along (or near) the interrogating neutron path, allowing an image of the spatial distribution of prompt induced fissions, and thereby fissionable material, to be constructed. A variety of induced-fission imaging measurements have been performed at Oak Ridge National Laboratory with a portable, low-dose D-T generator, including single-view radiographic measurements and three-dimensional tomographic measurements. Results from these measurements will be presented along with the neutron transmission images that have been performed simultaneously. This new capability may have applications to a number of areas in which there may be a need to confirm the presence or configuration of nuclear materials, such as nuclear material control and accountability, quality assurance, treaty confirmation, or homeland security applications.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Compact fission counter for DANCE

The Detector for Advanced Neutron Capture Experiments (DANCE) consists of 160 BF{sub 2} crystals with equal solid-angle coverage. DANCE is a 4{pi} {gamma}-ray calorimeter and designed to study the neutron-capture reactions on small quantities of radioactive and rare stable nuclei. These reactions are important for the radiochemistry applications and modeling the element production in stars. The recognition of capture event is made by the summed {gamma}-ray energy which is equivalent of the reaction Q-value and unique for a given capture reaction. For a selective group of actinides, where the neutron-induced fission reaction competes favorably with the neutron capture reaction, additional signature is needed to distinguish between fission and capture {gamma} rays for the DANCE measurement. This can be accomplished by introducing a detector system to tag fission fragments and thus establish a unique signature for the fission event. Once this system is implemented, one has the opportunity to study not only the capture but also fission reactions. A parallel-plate avalanche counter (PPAC) has many advantages for the detection of heavy charged particles such as fission fragments. These include fast timing, resistance to radiation damage, and tolerance of high counting rate. A PPAC also can be tuned to be insensitive to {alpha} particles, which is important for experiments with {alpha}-emitting actinides. Therefore, a PPAC is an ideal detector for experiments requiring a fast and clean trigger for fission. A PPAC with an ingenious design was fabricated in 2006 by integrating amplifiers into the target assembly. However, this counter was proved to be unsuitable for this application because of issues related to the stability of amplifiers and the ability to separate fission fragments from {alpha}'s. Therefore, a new design is needed. A LLNL proposal to develop a new PPAC for DANCE was funded by NA22 in FY09. The design goal is to minimize the mass for the proposed counter and still be able to maintain a stable operation under extreme radioactivity and the ability to separate fission fragments from {alpha}'s. In the following sections, the description is given for the design and performance of this new compact PPAC, for studying the neutron-induced reactions on actinides using DANCE at LANL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗