Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Sensitivity of the simulation of passive neutron emission from UF 6 cylinders to the uncertainties in both 19 F(α,n) energy spectrum and thick target yield of 234 U in UF 6

Interest in safeguards verification measurements using passive thermal neutron counting to assay 235 U content in large 30B UF 6 canisters has grown in recent years. Here, the prohibitively high cost and impracticality of using reference 30B calibration cylinders extensively will likely make accurate simulations of increasing interest. Accuracy of the simulated response will define the confidence in the predicted response and the extent to which simulations can reasonably be relied upon. With 234 U driven 19 F(α, n) reactions being the main neutron source in low enriched UF 6 the uncertainties of the 19 F(α, n) energy spectrum and the thick target yield of 234 U in UF 6 propagate into the uncertainty in the predicted response and represent a major influence of basic nuclear data. Here sensitivity of the simulated total (Singles) and coincidence (Doubles) count rates are assessed for the Passive Neutron Enrichment Meter using six potential 19 F(α, n) neutron energy spectra over a range of enrichments and material distributions. The results indicate that variations in the Singles and Doubles due to simulated (α, n) neutron spectrum are less than 1.5% for this set of simulated neutron spectra, with dependence varying inversely with enrichment. Singles uncertainty is only slightly less than that of the thick target 19 F(α, n) yield corresponding to the primary neutron source, whereas the 19 F(α, n) yield dependence of the Doubles is reduced by the non-negligible 238 U(SF) coincident neutron emissions. Based on available thick target 19 F(α, n) yield estimates the uncertainty is on the order of 5%, establishing this as the main nuclear data limitation when simulating thermal neutron detectors response for 30B UF 6 storage cylinders. Based on these findings, it appears that the measurement and evaluation of the thick target 19 F(α, n) yield for uranium hexafluoride is due.

19F(α,n) neutron spectrum↗

Determination of energy-dependent neutron backgrounds using shadow bars

Understanding the neutron background is essential for determining the neutron yield from nuclear reactions. Here, the neutron backgrounds were determined for heavy-ion collision experiment using the shadow-bar method, where beams of 40,48 Ca at 56, 140 MeV/u impinged on targets of 58,64 Ni and 112,124 Sn. In the analysis presented here, brass shadow bars are placed in front of organic liquid scintillator neutron detectors to determine the energy-dependent neutron background fractions. The measurement of neutron spectra with and without shadow bars is important to determine the neutron background more accurately. The neutron background, along with its sources and systematic uncertainties, are explored with a focus on the impact of background models and their dependence on neutron energy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The National Ignition Facility Neutron Imaging System

The National Ignition Facility (NIF) is scheduled to begin deuterium-tritium (DT) shots possibly in the next several years. One of the important diagnostics in understanding capsule behavior and to guide changes in Hohlraum illumination, capsule design, and geometry will be neutron imaging of both the primary 14 MeV neutrons and the lower-energy downscattered neutrons in the 6-13 MeV range. The neutron imaging system (NIS) described here, which we are currently building for use on NIF, uses a precisely aligned set of apertures near the target to form the neutron images on a segmented scintillator. The images are recorded on a gated, intensified charge coupled device. Although the aperture set may be as close as 20 cm to the target, the imaging camera system will be located at a distance of 28 m from the target. At 28 m the camera system is outside the NIF building. Because of the distance and shielding, the imager will be able to obtain images with little background noise. The imager will be capable of imaging downscattered neutrons from failed capsules with yields Y{sub n}>10{sup 14} neutrons. The shielding will also permit the NIS to function at neutron yields >10{sup 18}, which is in contrast to most other diagnostics that may not work at high neutron yields. The following describes the current NIF NIS design and compares the predicted performance with the NIF specifications that must be satisfied to generate images that can be interpreted to understand results of a particular shot. The current design, including the aperture, scintillator, camera system, and reconstruction methods, is briefly described. System modeling of the existing Omega NIS and comparison with the Omega data that guided the NIF design based on our Omega results is described. We will show NIS model calculations of the expected NIF images based on component evaluations at Omega. We will also compare the calculated NIF input images with those unfolded from the NIS images generated from our NIS numerical modeling code.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of HELIOS/BIPR/PARCS/MCNP6 Computation Route for WWER RPV Neutron Fluence Analysis and Validation Against Ex-Vessel Detector Measurement Data

Here, a computational route was developed for precise calculation of fast neutron fluence on a WWER-type reactor pressure vessel (RPV). The method is based on the transfer of neutronics data from HELIOS-2 lattice calculations and nodal diffusion neutronics data (power, density, and temperature) from BIPR7.1 and PARCS 3.36/PATHS core calculations into a three-dimensional (pinwise axially distributed) fixed neutron source for modeling of transport of fast neutrons from the reactor core to the outer surface of the RPV using MCNP6.2. Validation of the proposed computational method was carried out based on comparative analysis of MCNP6.2-predicted and neutron dosimetry–measured reaction rates [ 54 Fe(n,p) 54 Мn, 93 Nb(n,n') 93 mNb, and 58 Ni(n,р) 58 Со] on the outer surface of the Armenian Nuclear Power Plant (ANPP) Unit 2 RPV. Validation revealed that the MCNP6.2-predicted fast neutron fluence results are very sensitive to the ENDF-B neutron data. Particularly, MCNP6.2 with ENDF/B-VIII.0 significantly underpredicts (20% to 30%) fast neutron fluence while using ENDF/B-VII.1 data overpredicts it. Adding revised beta-released evaluations of 54 Fe, 56 Fe, 57 Fe, and 16 O from the International Nuclear Data Evaluation Network (INDEN) to ENDF/B-VIII.0 allows one to obtain reasonable agreement with measurement results for all types of measured reaction rates.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

HERSCHEL AND SPITZER OBSERVATIONS OF SLOWLY ROTATING, NEARBY ISOLATED NEUTRON STARS

Supernova fallback disks around neutron stars have been suspected to influence the evolution of the diverse neutron star populations. Slowly rotating neutron stars are the most promising places to find such disks. Searching for the cold and warm debris of old fallback disks, we carried out Herschel PACS (70 μm, 160 mu m) and Spitzer IRAC (3.6 μm, 4.5 μm) observations of eight slowly rotating (P ≈ 3-11 s) nearby (<1 kpc) isolated neutron stars. Herschel detected 160 μm emission (>5σ) at locations consistent with the positions of the neutron stars RX J0806.4-4123 and RX J2143.0+0654. No other significant infrared emission was detected from the eight neutron stars. We estimate probabilities of 63%, 33%, and 3% that, respectively, none, one, or both Herschel PACS 160 μm detections are unrelated excess sources due to background source confusion or an interstellar cirrus. If the 160 μm emission is indeed related to cold (10-22 K) dust around the neutron stars, this dust is absorbing and re-emitting ∼10% to ∼20% of the neutron stars' X-rays. Such high efficiencies would be at least three orders of magnitude larger than the efficiencies of debris disks around nondegenerate stars. While thin dusty disks around the neutron stars can be excluded as counterparts of the 160 μm emission, dusty asteroid belts constitute a viable option.

79 ASTRONOMY AND ASTROPHYSICS↗

Monitoring method for neutron flux for a spallation target in an accelerator driven sub-critical system

Here in this paper, we study a monitoring method for neutron flux for the spallation target used in an accelerator driven sub-critical (ADS) system, where a spallation target located vertically at the centre of a sub-critical core is bombarded vertically by high-energy protons from an accelerator. First, by considering the characteristics in the spatial variation of neutron flux from the spallation target, we propose a multi-point measurement technique, i.e. the spallation neutron flux should be measured at multiple vertical locations. To explain why the flux should be measured at multiple locations, we have studied neutron production from a tungsten target bombarded by a 250 MeV-proton beam with Geant4-based Monte Carlo simulations. The simulation results indicate that the neutron flux at the central location is up to three orders of magnitude higher than the flux at lower locations. Secondly, we have developed an effective technique in order to measure the spallation neutron flux with a fission chamber (FC), by establishing the relation between the fission rate measured by FC and the spallation neutron flux. Since this relation is linear for a FC, a constant calibration factor is used to derive the neutron flux from the measured fission rate. This calibration factor can be extracted from the energy spectra of spallation neutrons. Finally, we have evaluated the proposed calibration method for a FC in the environment of an ADS system. The results indicate that the proposed method functions very well.

43 PARTICLE ACCELERATORS↗

Extraction of the neutron electric form factor from measurements of inclusive double spin asymmetries

Background: Measurements of the neutron charge form factor, G$n\atop{E}$, are challenging because the neutron has no net charge. Additionally, measurements of the neutron form factors must use nuclear targets which require accurately accounting for nuclear effects. Extracting G$n\atop{E}$ with different targets and techniques provides an important test of our handling of these effects. Purpose: The goal of the measurement was to use an inclusive asymmetry measurement technique to extract the neutron charge form factor at a four-momentum transfer of 1 (GeV/c) 2 . This technique has very different systematic uncertainties than traditional exclusive measurements and thus serves as an independent check of whether nuclear effects have been taken into account correctly. Method: The inclusive quasielastic reaction 3 $→\atop{He}$ ($→\atop{e}$, e') was measured at Jefferson Laboratory. The neutron electric form factor, G$n\atop{E}$, was extracted at Q 2 = 0.98 ( GeV/c) 2 from ratios of electron-polarization asymmetries measured for two orthogonal target spin orientations. This Q 2 is high enough that the sensitivity to G$n\atop{E}$ is not overwhelmed by the neutron magnetic contribution, and yet low enough that explicit neutron detection is not required to suppress pion production. Results: The neutron electric form factor, G$n\atop{E}$, was determined to be 0.0414 ± 0.0077 ( stat ) ± 0.0022 ( syst ), providing the first high-precision inclusive extraction of the neutron's charge form factor. In conclusion: The use of the inclusive quasielastic 3 $→\atop{He}$ ($→\atop{e}$, e') with a four-momentum transfer near 1 (GeV/c) 2 has been used to provide a unique measurement of G$n\atop{E}$. This new result provides a systematically independent validation of the exclusive extraction technique results and implies that the nuclear corrections are understood. This is contrary to the proton form factor where asymmetry and differential cross section measurements have been shown to have large systematic differences.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SURVEY OF COUPLING SCHEMES IN TRADITIONAL COUPLED NEUTRONICS AND THERMAL-HYDRAULICS CODES

The design and the analysis of nuclear power plants (NPPs) require computational codes to predict the behavior of the NPP nuclear components and other systems (i.e., reactor core, primary coolant system, emergency core cooling system, etc.). Coupled calculations are essential to the conduct of deterministic safety assessments. Inasmuch as the physical phenomena that govern the performance of a nuclear reactor are always present simultaneously, ideally computational modeling of a nuclear reactor should include coupled codes that represent all of the active physical phenomena. Such multi-physics codes are under development at several institutions and are expected to become operational in the future. However, in the interim, integrated codes that incorporate modeling capabilities for two to three physical phenomena will remain useful. For example, in the conduct of safety analyses, of paramount importance are codes that couple neutronics and thermal-hydraulics, especially transient codes. Other code systems of importance to safety analyses are those that couple primary system thermal-hydraulics to fission product chemistry, neutronics to fuel performance, containment behavior and structural mechanics to thermal-hydraulics, etc. This paper surveys the methods used traditionally in the coupling of neutronic and thermal-hydraulics codes. The neutron kinetics codes are used for computing the space-time evolution of the neutron flux and, hence, of the power distribution. The thermal-hydraulics codes, which compute mass, momentum and energy transfers, model the coolant flow and the temperature distribution. These codes can be used to compute the neutronic behavior and the thermal-hydraulic states separately. However, the need to account with fidelity for the dynamic feedback between the two sets of properties (via temperature and density effects on the cross section inputs into the neutronics codes) and the requirement to model realistically the transient response of nuclear power plants and to assess the associated emergency systems and procedures imply the necessity of modeling the neutronic and thermal-hydraulics simultaneously within a coupled code system. The focus of this paper is a comparison of the methods by which the coupling between neutron kinetics and thermal-hydraulics treatments has been traditionally achieved in various code systems. As discussed in the last section, the modern approaches to multi-physics code development are beyond the scope of this paper.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-F-T-217: A Comprehensive Monte-Carlo Study of Out-Of-Field Secondary Neutron Spectra in a Scanned-Beam Proton Therapy Treatment Room

Purpose: To simulate secondary neutron radiation-fields produced at different positions during phantom irradiation inside a scanning proton therapy gantry treatment room. Further, to identify origin, energy distribution and angular emission as function of proton beam energy. Methods: GEANT4 and FLUKA Monte-Carlo codes were used to model the relevant parts of the treatment room in a gantry-equipped pencil beam scanning proton therapy facility including walls, floor, metallic gantry-components, patient table and the homogeneous PMMA target. The proton beams were modeled based on experimental beam ranges in water and spot shapes in air. Neutron energy spectra were simulated at 0°, 45°, 90° and 135° relative to the beam axis at 2m distance from isocenter, as well as 11×11 cm2 fields for 75MeV, 140MeV, 200MeV and for 118MeV with 5cm PMMA range-shifter. The total neutron energy distribution was recorded for these four positions and proton energies. Additionally, the room-components generating secondary neutrons in the room and their contributions to the total spectrum were identified and quantified. Results: FLUKA and GEANT4 simulated neutron spectra showed good general agreement in the whole energy range of 10{sup −}9 to 10{sup 2} MeV. Comparison of measured spectra with the simulated contributions of the various room components helped to limit the complexity of the room model, by identifying the dominant contributions to the secondary neutron spectrum. The iron of the bending magnet and counterweight were identified as sources of secondary evaporation-neutrons, which were lacking in simplified room models. Conclusion: Thorough Monte-Carlo simulations have been performed to complement Bonner-sphere spectrometry measurements of secondary neutrons in a clinical proton therapy treatment room. Such calculations helped disentangling the origin of secondary neutrons and their dominant contributions to measured spectra, besides providing a useful validation of widely used Monte-Carlo packages in comparison to experimental data. Cluster of Excellence of the German Research Foundation (DFG) “Munich-Centre for Advanced Photonics (MAP)”.

60 APPLIED LIFE SCIENCES↗

SU-F-T-657: In-Room Neutron Dose From High Energy Photon Beams

Purpose: To estimate neutron dose inside the treatment room from photodisintegration events in high energy photon beams using Monte Carlo simulations and experimental measurements. Methods: The Monte Carlo code MCNP6 was used for the simulations. An Eberline ESP-1 Smart Portable Neutron Detector was used to measure neutron dose. A water phantom was centered at isocenter on the treatment couch, and the detector was placed near the phantom. A Varian 2100EX linear accelerator delivered an 18MV open field photon beam to the phantom at 400MU/min, and a camera captured the detector readings. The experimental setup was modeled in the Monte Carlo simulation. The source was modeled for two extreme cases: a) hemispherical photon source emitting from the target and b) cone source with an angle of the primary collimator cone. The model includes the target, primary collimator, flattening filter, secondary collimators, water phantom, detector and concrete walls. Energy deposition tallies were measured for neutrons in the detector and for photons at the center of the phantom. Results: For an 18MV beam with an open 10cm by 10cm field and the gantry at 180°, the Monte Carlo simulations predict the neutron dose in the detector to be 0.11% of the photon dose in the water phantom for case a) and 0.01% for case b). The measured neutron dose is 0.04% of the photon dose. Considering the range of neutron dose predicted by Monte Carlo simulations, the calculated results are in good agreement with measurements. Conclusion: We calculated in-room neutron dose by using Monte Carlo techniques, and the predicted neutron dose is confirmed by experimental measurements. If we remodel the source as an electron beam hitting the target for a more accurate representation of the bremsstrahlung fluence, it is feasible that the Monte Carlo simulations can be used to help in shielding designs.

60 APPLIED LIFE SCIENCES↗

The crystal acceleration effect for cold neutrons

A new mechanism of neutron acceleration is discussed and studied experimentally in detail for cold neutrons passing through the accelerated perfect crystal with the energies close to the Bragg one. The effect arises due to the following reason. The crystal refraction index (neutron-crystal interaction potential) for neutron in the vicinity of the Bragg resonance sharply depends on the parameter of deviation from the exact Bragg condition, i.e. on the crystal-neutron relative velocity. Therefore the neutrons enter into accelerated crystal with one neutron-crystal interaction potential and exit with the other. Neutron kinetic energy cannot vary inside the crystal due to its homogeneity. So after passage through such a crystal neutrons will be accelerated or decelerated because of the different energy change at the entrance and exit crystal boundaries.

74 ATOMIC AND MOLECULAR PHYSICS↗

Nuclear threshold effects and neutron strength functions

The present work is devoted to study of spectroscopic aspects, in terms of neutron strength function, for the threshold effects with non-light nuclei. Relations to the neutron strength functions of the anomal effects observed at threshold of neutron analogue channel, in deuteron stripping reactions on A ≈ 90 mass target nuclei and in nucleon mirror reactions with A ≈ 30 nuclei, are established. It is proved that these threshold effects follow the mass dependance of the neutron strength functions. The connection between threshold effects and neutron strength functions, proves that the threshold effects are related to spectroscopy of ancestral zero-energy neutron particle resonance. One can conclude the threshold effects depend not only on penetration factors of opening neutron channel, as in Cusp Theory, but also on Multichannel Reaction Dynamics as well as on Spectroscopy of neutron threshold state. The present study is based on Reduced Scattering Matrix, describing the effect of invisible threshold channel on open observed ones. The determining role of Nuclear Reaction Dynamics, Quasiresonant Scattering and Spectroscopy of Neutron Threshold State, on threshold effects is evinced.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Correlation of the neutron yield anisotropy with the electrical characteristics of a plasma focus discharge

The anisotropy of the yield and energy of neutrons generated in a small-size plasma focus chamber with a total neutron yield of about 4 x 10{sup 9} DD neutrons per shot was investigated experimentally. The neutrons were recorded using scintillation detectors on a 3-m-long flight base. The measurements were performed at the angles 0{sup o} and 90{sup o} with respect to the chamber axis. The maximum neutron energy measured by the time-of-flight method at the angles 0{sup o} and 90{sup o} was found to be 2.8 and 2.5 MeV, respectively. The measured anisotropy of the neutron yield was in the range 1.15-1.88. The integral DD neutron yield of the source was measured using the activation method (by activating silver isotopes). It is found that the neutron yield and the yield anisotropy depend linearly on the discharge current jump {Delta}I at the instant of neutron generation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron Rodeo Phase II Final Report

The ability to perform nondestructive assay (NDA) of fresh fuel assemblies with high precision in reasonable measurement times is significant for nuclear nonproliferation and safeguards. The current methodology used by the International Atomic Energy Agency (IAEA) for NDA of fresh fuel assemblies involves a He-3 based Uranium Neutron Collar (UNCL) system, which is an active coincidence counting system designed to measure time-correlated neutron doubles from induced fissions within the assembly. The UNCL system provides an easily implementable process of quantifying the 235 U linear density of the fresh fuel assemblies; however, operational limitations of the UNCL include long assay times and adverse sensitivity to poisoned assemblies. This has engendered investigation in alternative detector materials for fast-neutron counting to rectify some of these current limitations in the UNCL. The potential improvements of using fast-neutron organic scintillators (e.g. liquid scintillators, stilbene, PSDcapable plastics, etc.) was compared directly to the original Uranium Neutron Collar (UNCL) in-detail during the initial Advanced Neutron Detection Technology Rodeo. The simulation results showed that these alternative detector materials can provide an improvement in the assay time required to reach a suitable precision due to both their lower sensitivity to the interrogation source neutrons (i.e. AmLi neutrons) and their inherently shorter coincidence gate widths. The IAEA has developed a liquid scintillator-based Fast-Neutron Collar (FNCL) as a potential replacement system for the UNCL.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Report on the Tin-II Thermal Neutron Detector

Thermal neutrons have recently become a concern in the semiconductor community where it has been reported that approximately 20% of the single-event upsets are due to thermal neutrons in some devices. The goal of this project is to measure the intensity of thermal neutrons in the High- Performance Computing (HPC) area. This is part of a larger effort to characterize the radiation environment in the HPC area which includes high-energy neutrons as well as thermal neutrons. To accomplish this goal, we designed and fabricated a neutron detector that is sensitive to thermal neutrons called Tin-II. The Tin-II detector consists of two identical 3He ionization chambers with one detector bare and one detector shielded with cadmium. Because the cadmium shielding effectively blocks the thermal neutrons, the difference in count rates between these two detectors reflect the number of thermal neutrons detected. This report summarizes the status of our efforts to develop this detector.

47 OTHER INSTRUMENTATION↗

Exploring the Limits of Biological Complexity Amenable to Studies by Incoherent Neutron Spectroscopy

The wavelengths of neutrons available at neutron scattering facilities are comparable with intra- and inter-molecular distances, while their energies are comparable with molecular vibrational energies, making such neutrons highly suitable for studies of molecular-level dynamics. The unmistakable trend in neutron spectroscopy has been towards measurements of systems of greater complexity. Several decades of studies of dynamics using neutron scattering have witnessed a progression from measurements of solids to liquids to protein complexes and biomembranes, which may exhibit properties characteristic of both solids and liquids. Over the last two decades, the frontier of complexity amenable to neutron spectroscopy studies has reached the level of cells. Considering this a baseline for neutron spectroscopy of systems of the utmost biological complexity, we briefly review what has been learned to date from neutron scattering studies at the cellular level and then discuss in more detail the recent strides into neutron spectroscopy of tissues and whole multicellular organisms.

59 BASIC BIOLOGICAL SCIENCES↗

Progress in Constraining Nuclear Symmetry Energy Using Neutron Star Observables Since GW170817

The density dependence of nuclear symmetry energy is among the most uncertain parts of the Equation of State (EOS) of dense neutron-rich nuclear matter. It is currently poorly known especially at suprasaturation densities partially because of our poor knowledge about isovector nuclear interactions at short distances. Because of its broad impacts on many interesting issues, pinning down the density dependence of nuclear symmetry energy has been a longstanding and shared goal of both astrophysics and nuclear physics. New observational data of neutron stars including their masses, radii, and tidal deformations since GW170817 have helped improve our knowledge about nuclear symmetry energy, especially at high densities. Based on various model analyses of these new data by many people in the nuclear astrophysics community, while our brief review might be incomplete and biased unintentionally, we learned in particular the following: (1) The slope parameter L of nuclear symmetry energy at saturation density ρ0 of nuclear matter from 24 new analyses of neutron star observables was about L≈57.7±19 MeV at a 68% confidence level, consistent with its fiducial value from surveys of over 50 earlier analyses of both terrestrial and astrophysical data within error bars. (2) The curvature Ksym of nuclear symmetry energy at ρ0 from 16 new analyses of neutron star observables was about Ksym≈−107±88 MeV at a 68% confidence level, in very good agreement with the systematics of earlier analyses. (3) The magnitude of nuclear symmetry energy at 2ρ0, i.e., Esym(2ρ0)≈51±13 MeV at a 68% confidence level, was extracted from nine new analyses of neutron star observables, consistent with the results from earlier analyses of heavy-ion reactions and the latest predictions of the state-of-the-art nuclear many-body theories. (4) While the available data from canonical neutron stars did not provide tight constraints on nuclear symmetry energy at densities above about 2ρ0, the lower radius boundary R2.01=12.2 km from NICER’s very recent observation of PSR J0740+6620 of mass 2.08±0.07M⊙ and radius R=12.2–16.3 km at a 68% confidence level set a tight lower limit for nuclear symmetry energy at densities above 2ρ0. (5) Bayesian inferences of nuclear symmetry energy using models encapsulating a first-order hadron–quark phase transition from observables of canonical neutron stars indicated that the phase transition shifted appreciably both L and Ksym to higher values, but with larger uncertainties compared to analyses assuming no such phase transition. (6) The high-density behavior of nuclear symmetry energy significantly affected the minimum frequency necessary to rotationally support GW190814’s secondary component of mass (2.50–2.67) M⊙ as the fastest and most massive pulsar discovered so far. Overall, thanks to the hard work of many people in the astrophysics and nuclear physics community, new data of neutron star observations since the discovery of GW170817 have significantly enriched our knowledge about the symmetry energy of dense neutron-rich nuclear matter.

79 ASTRONOMY AND ASTROPHYSICS↗

Neutron yields from 435 MeV/nucleon Nb stopping in Nb and 272 MeV/nucleon Nb stopping in Nb and Al

Neutron fluences were measured from 435 MeV/nucleon Nb ions stopping in a Nb target and 272 MeV/nucleon Nb ions stopping in targets of Nb and Al for neutrons above 20 MeV and at laboratory angles between 3 degrees and 80 degrees. The resultant spectra were integrated over angles to produce neutron energy distributions and over energy to produce neutron angular distributions. The total neutron yields for each system were obtained by integrating over the angular distributions. The angular distributions from all three systems are peaked forward, and the energy distributions from all three systems show an appreciable yield of neutrons with velocities greater than the beam velocity. Comparison of the total neutron yields from the two Nb + Nb systems suggests that the average neutron multiplicity decreases with decreasing projectile energy. Comparison of the total yields from the two 272 MeV/nucleon systems suggests that the total yields show the same dependence on projectile and target mass number as do total inclusive neutron cross sections. The data are compared with Boltzmann-Uehling-Uhlenbeck model calculations.

NASA Discipline Radiation Health↗