Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NEUTRON SCIENCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Multi-Ton Argon and Xenon

There is a wide range of astronomical evidence that the visible stars and gas in all galaxies, including our own, are immersed in a much larger cloud of non-luminous matter, typically an order of magnitude greater in total mass. The existence of this ''dark matter'' is consistent with evidence from large-scale galaxy surveys and microwave background measurements, indicating that the majority of matter in the universe is non-baryonic. The nature of this non-baryonic component is still totally unknown, and the resolution of the ''dark matter puzzle'' is of fundamental importance to cosmology, astrophysics, and elementary particle physics. A leading explanation, motivated by supersymmetry theory, is the existence of as yet undiscovered Weakly Interacting Massive Particles (WIMPs), formed in the early universe and subsequently clustered in association with normal matter. WIMPs could, in principle, be detected in terrestrial experiments by their collisions with ordinary nuclei, giving observable low energy (< 100 keV) nuclear recoils. The predicted low collision rates require ultra-low background detectors with large (0.1-10 ton) target masses, located in deep underground sites to eliminate neutron background from cosmic ray muons. The establishment of the Deep Underground Science and Engineering Laboratory for large-scale experiments of this type would strengthen the current leadership of US researchers in this and other particle astrophysics areas. We propose to detect nuclear recoils by scintillation and ionization in ton-scale liquid noble gas targets, using techniques already proven in experiments at the 0.01-0.1 ton level. The experimental challenge is to identify these events in the presence of background events from gammas, neutrons, and alphas.

43 PARTICLE ACCELERATORS↗

Water Dynamics in Cancer Cells: Lessons from Quasielastic Neutron Scattering

The severity of the cancer statistics around the globe and the complexity involving the behavior of cancer cells inevitably calls for contributions from multidisciplinary areas of research. As such, materials science became a powerful asset to support biological research in comprehending the macro and microscopic behavior of cancer cells and untangling factors that may contribute to their progression or remission. The contributions of cellular water dynamics in this process have always been debated and, in recent years, experimental works performed with Quasielastic neutron scattering (QENS) brought new perspectives to these discussions. In this review, we address these works and highlight the value of QENS in comprehending the role played by water molecules in tumor cells and their response to external agents, particularly chemotherapy drugs. In addition, this paper provides an overview of QENS intended for scientists with different backgrounds and comments on the possibilities to be explored with the next-generation spectrometers under construction.

60 APPLIED LIFE SCIENCES↗

Early detection of deteriorations affecting neutrons boron detectors

The objective of these studies is to design and to industrialize a new device taking back the features of the actual system of control of boron detectors and updating them by adding some analysis of the pulses shapes for predictive maintenance. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Instrumented Advanced Test Reactor Irradiation Capsule Experiment for In-situ Thermal Conductivity Measurements of High-Density Fuels

Idaho National Laboratory (INL) is developing a first-of-a-kind leadout instrumented capsule experiment design to enable in-situ measurement capabilities in the Advanced Test Reactor (ATR) core. The Ceramic Advanced Thermal Evolution Research (CRATER) experiment supports the aLEU program objective to accelerate fuel performance irradiation testing for identifying alternative high-assay, low enriched uranium (HALEU) fuel systems. CRATER is a fueled, instrumented capsule experiment to measure in-situ temperature and thermal conductivity of ceramic fuels. Two ceramic fuel types will be used, uranium mono-nitride (UN) and uranium mono-carbide (UC), with a third metallic fuel used for comparison (UMo). The three fuel specimens will use a stainless-steel cladding. Programmatic objectives include linear heat generation rates (LHGR) of 210 ± 25 Watts per cm. and an inner clad temperature of 300-450 °C. The evolution of fuel thermal conductivity during irradiation has never been successfully measured in-situ for these systems and this experiment is designed to use advances in measurement sciences to characterize how thermal transport properties evolve while in reactor. Neutronic simulations of the experiment and its surrounding reactor environment were conducted using the Monte Carlo N-Particle Transport code (MCNP) and result in optimized fuel enrichment to meet target linear heat generation rates (LHGRs) influencing fuel temperatures, and fuel burnup requirements. Fabrication research and development (R&D) efforts are underway to produce annular right cylinder UC and UN pellets using carbothermic reduction and nitridation (or hydride-dehydride-nitride) synthesis methods, followed double-action die cold isostatic pressing.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermal Performance of Neutron Sensor Qualification Device

The neutron sensor qualification device was developed to provide a temperature-controlled environment for neutron sensors and dosimetry, enabling irradiation in a neutron field at the Armed Forces Radiobiology Research Institute (AFRRI) TRIGA reactor facility. The device, constructed from low-activation and low neutron cross-section materials, features a modular tube furnace design with three independently controlled heating zones for controlling axial temperature distribution. Laboratory testing validated the device's thermal performance, including uniform temperature distribution with less than 6°C variation across the central region, a steady-state operational temperature of 350°C achieved in approximately 3 hours, and a cooling time constant of 3.5 hours. External surface temperatures remained safe for handling, with the surrounding aluminum structure remaining at ambient conditions. The results confirm the device’s suitability for neutron sensor qualification experiments, with potential for future operation at higher temperatures and further optimization of performance.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

In-situ neutron diffraction and crystal plasticity finite element modeling to study the kinematic stability of retained austenite in bearing steels

This work integrates in-situ neutron diffraction and crystal plasticity finite element modeling to study the kinematic stability of retained austenite in high carbon bearing steels. The presence of a kinematically metastable retained austenite in bearing steels can significantly affect the macro-mechanical and micro-mechanical material response. Mechanical characterization of metastable austenite is a critical component in accurately capturing the micro-mechanical behavior under typical application loads. Traditional mechanical characterization techniques are unable to discretely quantify the micro-mechanical response of the austenite, and as a result, the computational predictions rely heavily on trial and error or qualitative descriptions of the austenite phase. In order to overcome this, in the present work, we use in-situ neutron diffraction of a uniaxial tension test of an A485 Grade 1 bearing steel specimen. The mechanical response determined from the neutron diffraction analysis was incorporated into a hybrid crystal plasticity finite element model that accounts for the martensite's crystal plasticity and the stress-assisted transformation from austenite to martensite in bearing steels. Here, the modeling response was used to estimate the single crystal elastic constants of the austenite and martensite phases. Finally, the results show that using in-situ neutron diffraction, coupled with a crystal plasticity model, can successfully predict both the micro-mechanical and macro-mechanical responses of bearing steels while accounting for the martensitic transformation of the retained austenite.

36 MATERIALS SCIENCE↗

Crystallographic changes in lead zirconate titanate due to neutron irradiation

Piezoelectric and ferroelectric materials are useful as the active element in non-destructive monitoring devices for high-radiation areas. Here, crystallographic structural refinement (i.e., the Rietveld method) is used to quantify the type and extent of structural changes in PbZr 0 .5 Ti 0 .5 O 3 after exposure to a 1 MeV equivalent neutron fluence of 1.7 × 10 15 neutrons/cm 2 . The results show a measurable decrease in the occupancy of Pb and O due to irradiation, with O vacancies in the tetragonal phase being created preferentially on one of the two O sites. The results demonstrate a method by which the effects of radiation on crystallographic structure may be investigated.

36 MATERIALS SCIENCE↗

Thermodynamic and Structural Investigations of Ammonium Borohydride, a Solid with a Highest Content of Thermodynamically and Kinetically Accessible Hydrogen

The US DOE issued a Grand Challenge for Basic Research Needs for the Hydrogen Economy calling in part for significant new breakthroughs in novel materials and approaches to store hydrogen on-board fuel cell powered vehicles. The Challenge specified several technical criteria for hydrogen storage materials that are necessary to provide sufficient energy density to drive a Fuel Cell powered vehicle >300 miles between refueling. The formation of AB catalyzing the decomposition of NH4BH4 to DADB and hydrogen provides insight into why NH4BH4 appears to be less stable than predicted by electronic structure theory. Further work is planned to investigate the structure of NH4BH4 by neutron diffraction to see if it is possible to induce a phase change at lower temperatures to the zincblende structure predicted to be the most stable structure at 0 K. This work was supported by the Office of Basic Energy Sciences, Chemical Sciences Division of the U.S. Department of Energy (DOE). A portion of the research described in this paper was performed in the W.R. Wiley Environmental Molecular Sciences Laboratory, a national scientific user facility sponsored by the Department of Energy’s Office of Biological and Environmental Research and located at Pacific Northwest National Laboratory. Pacific Northwest National Laboratory is operated for the DOE by Battelle.

08 HYDROGEN↗

A neutron imaging device for sample alignment in a pulsed neutron scattering instrument

A neutron-imaging device for alignment purposes has been tested on the INES beamline at ISIS, the pulsed neutron source of Rutherford Appleton Laboratory (U.K.). Its use, in conjunction with a set of movable jaws, turns out extremely useful for scattering application to complex samples where a precise and well-defined determination of the scattering volume is needed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compound Refractive Lenses for Thermal Neutron Applications

This project designed and built compound refractive lenses (CRLs) that are able to focus, collimate and image using thermal neutrons. Neutrons are difficult to manipulate compared to visible light or even x rays; however, CRLs can provide a powerful tool for focusing, collimating and imaging neutrons. Previous neutron CRLs were limited to long focal lengths, small fields of view and poor resolution due to the materials available and manufacturing techniques. By demonstrating a fabrication method that can produce accurate, small features, we have already dramatically improved the focal length of thermal neutron CRLs, and the manufacture of Fresnel lens CRLs that greatly increases the collection area, and thus efficiency, of neutron CRLs. Unlike a single lens, a compound lens is a row of N lenslets that combine to produce an N-fold increase in the refraction of neutrons. While CRLs can be made from a variety of materials, we have chosen to mold Teflon lenses. Teflon has excellent neutron refraction, yet can be molded into nearly arbitrary shapes. We designed, fabricated and tested Teflon CRLs for neutrons. We demonstrated imaging at wavelengths as short as 1.26 Å with large fields of view and achieved resolution finer than 250 μm which is better than has been previously shown. We have also determined designs for Fresnel CRLs that will greatly improve performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhancements to Rad/Nuke Search Algorithms, RSLA-004-17, Year 1 of 1

This presentation describes investigation into new ways to improve the radiological/nuclear detection performance (gamma ray and neutron) in deployed emergency response equipment and to develop a more efficient and effective use of advanced algorithms, including spectral anomaly detection schemes that are designed to exploit modern-day enhancements to sensors, data quality, and computing resources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron beam imaging at neutron spectrometers at Dhruva

A low efficiency, 2-Dimensional Position Sensitive Neutron Detector based on delay line position encoding is developed. It is designed to handle beam flux of 10{sup 6}-10{sup 7} n/cm{sup 2}/s and for monitoring intensity profiles of neutron beams. The present detector can be mounted in transmission mode, as the hardware allows maximum neutron transmission in sensitive region. Position resolution of 1.2 mm in X and Y directions, is obtained. Online monitoring of beam images and intensity profile of various neutron scattering spectrometers at Dhruva are presented. It shows better dynamic range of intensity over commercial neutron camera and is also time effective over the traditionally used photographic method.

43 PARTICLE ACCELERATORS↗

Displacement damage effects on CMOS APS image sensors induced by neutron irradiation from a nuclear reactor

The experiments of displacement damage effects on CMOS APS image sensors induced by neutron irradiation from a nuclear reactor are presented. The CMOS APS image sensors are manufactured in the standard 0.35 μm CMOS technology. The flux of neutron beams was about 1.33 × 10{sup 8} n/cm{sup 2}s. The three samples were exposed by 1 MeV neutron equivalent-fluence of 1 × 10{sup 11}, 5 × 10{sup 11}, and 1 × 10{sup 12} n/cm{sup 2}, respectively. The mean dark signal (K{sub D}), dark signal spike, dark signal non-uniformity (DSNU), noise (V{sub N}), saturation output signal voltage (V{sub S}), and dynamic range (DR) versus neutron fluence are investigated. The degradation mechanisms of CMOS APS image sensors are analyzed. The mean dark signal increase due to neutron displacement damage appears to be proportional to displacement damage dose. The dark images from CMOS APS image sensors irradiated by neutrons are presented to investigate the generation of dark signal spike.

36 MATERIALS SCIENCE↗

Neutron Noise Analysis of the Neptunium Subcritical Observation (NESO) Experiment

The Neptunium Subcritical Observation (NeSO) experiment was a subcritical integral benchmark experiment. This experiment was designed in 2017-2018 and was performed at the National Criticality Experiments Research Center (NCERC) in 2019. Eight different subcritical configurations were measured with varying Nickel reflector thickness. For all configurations, a 3 He detection system was used to record neutron events. The focus of this work is to share neutron noise results of the measured data.

3-Helium↗

The Study of Neutrons Stars with the Chandra X-Ray Observatory

Dr. Weisskopf will lecture on the use of the Chandra X-Ray Observatory to study neutron stars (and black holes). He will draw on the proposal preparation tool made public by NASA through the Chandra X-Ray Science Center to walk students through the details of the process. Technical examples of studies of several types of neutron star systems (isolated, Be-star, low mass, high-mass) will be used as illustrations and in this way he will tie the physics to the observatory.

Weisskopf, Martin C.↗

Physics design of a cold neutron source for KIPT neutron source facility.

Argonne National Laboratory (ANL) of USA and Kharkov Institute of Physics and Technology (KIPT) of Ukraine have been collaborating on the conceptual design development of a neutron source facility. It is based on the use of an electron accelerator driven subcritical (ADS) facility with low enriched uranium fuel, using the existing electron accelerators at KIPT of Ukraine [1]. The neutron source of the subcritical assembly is generated from the interaction of 100-KW electron beam, which has a uniform spatial distribution and the electron energy in the range of 100 to 200 MeV, with a natural uranium target [2]. The main functions of the facility are the production of medical isotopes and the support of the Ukraine nuclear power industry. Neutron beam experiments and material studies are also included. Over the past two-three decades, structures with characteristic lengths of 100 {angstrom} and correspondingly smaller vibrational energies have become increasingly important for both science and technology [3]. The characteristic dimensions of the microstructures can be well matched by neutrons with longer vibrational wavelength and lower energy. In the accelerator-driven subcritical facility, most of the neutrons are generated from fission reactions with energy in the MeV range. They are slowed down to the meV energy range through scattering reactions in the moderator and reflector materials. However, the fraction of neutrons with energies less than 5 meV in a normal moderator spectrum is very low because of up-scattering caused by the thermal motion of moderator or reflector molecules. In order to obtain neutrons with energy less than 5 meV, cryogenically cooled moderators 'cold neutron sources' should be used to slow down the neutrons. These cold moderators shift the neutron energy spectrum down because the thermal motion of moderator molecules as well as the up-scattering is very small, which provides large gains in intensity of low energy neutrons, E < 5 meV. The accelerator driven subcritical facility is designed with a provision to add a cryogenically cooled moderator system. This cold neutron source could provide the neutrons beams with lower energy, which could be utilized in scattering experiment and material structures analysis. This study describes the performed physics analyses to define and characterize the cold neutron source of the KIPT neutron source facility. The cold neutron source is designed to optimize the cold neutron brightness to the experimental instruments outside the radial heavy concrete shield of the facility. Liquid hydrogen or solid methane with 20 K temperature is used as a cold moderator. Monte Carlo computer code MCNPX [4], with ENDF/B-VI nuclear data libraries, is utilized to calculate the cold neutron source performance and estimate the nuclear heat load to the cold moderator. The surface source generation capability of MCNPX code has been used to provide the possibility of analyzing different design configurations and perform design optimization analyses with reasonable computer resources. Several design configurations were analyzed and their performance were characterized and optimized.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Characterization of a mixed high-energy spallation neutron–proton field using monoisotopic activation detectors

In this paper, we used monoisotopic Co, Au, and Bi threshold activation detectors to characterize the high-energy ( > 5 MeV) portion of a mixed spallation neutron–proton (n/p) field. The field was produced by irradiating the natural uranium target–blanket subcritical assembly Quinta with 660-MeV protons from Phasotron accelerator at the Joint Institute for Nuclear Research (JINR) in Dubna. Experimental yields of the (n,x) and (p,x) reactions were compared to the calculated reaction rates, which represent the convolution of particle flux and reaction cross section. The flux was simulated using the radiation transport code MCNPX 2.7.0, and the cross sections were extracted from the following three sources: the intranuclear cascade model INCL4.2, the phenomenological spherical optical model from TALYS-1.8, and the evaluated nuclear data file TENDL-2015. We show that, in most cases, the evaluated data provide a closer agreement with the experimental data in comparison with INCL4.2 model, which is an integral part of MCNPX. Finally, our results bring a contribution to those fields of physics research that utilize computer prediction of neutron generation in the energy range of tens to hundreds MeV, such as the medical radioisotope production, radiation shielding of spallation neutron sources, and nuclear transmutation in accelerator-driven systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved joint X-ray and neutron refinement procedure in Phenix

Neutron diffraction is one of the three crystallographic techniques (X-ray, neutron and electron diffraction) used to determine the atomic structures of molecules. Its particular strengths derive from the fact that H (and D) atoms are strong neutron scatterers, meaning that their positions, and thus protonation states, can be derived from crystallographic maps. However, because of technical limitations and experimental obstacles, the quality of neutron diffraction data is typically much poorer (completeness, resolution and signal to noise) than that of X-ray diffraction data for the same sample. Further, refinement is more complex as it usually requires additional parameters to describe the H (and D) atoms. The increase in the number of parameters may be mitigated by using the `riding hydrogen' refinement strategy, in which the positions of H atoms without a rotational degree of freedom are inferred from their neighboring heavy atoms. However, this does not address the issues related to poor data quality. Therefore, neutron structure determination often relies on the presence of an X-ray data set for joint X-ray and neutron (XN) refinement. In this approach, the X-ray data serve to compensate for the deficiencies of the neutron diffraction data by refining one model simultaneously against the X-ray and neutron data sets. To be applicable, it is assumed that both data sets are highly isomorphous, and preferably collected from the same crystals and at the same temperature. However, the approach has a number of limitations that are discussed in this work by comparing four separately re-refined neutron models. To address the limitations, a new method for joint XN refinement is introduced that optimizes two different models against the different data sets. This approach is tested using neutron models and data deposited in the Protein Data Bank. The efficacy of refining models with H atoms as riding or as individual atoms is also investigated.

36 MATERIALS SCIENCE↗