Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Collimated electron beam accelerated at 12 kV from a Penning discharge

A pulsed electron beam accelerated at 12 kV with a duration of 40 μs per pulse is obtained from a Penning discharge with a hollow anode and two cathodes. The electrons are extracted through a hole in one of the cathodes and focused by a pair of coils. The electron beam has a diameter of a few mm in the cross section, while the beam current reaches peak values of 400 mA, depending on the magnetic field inside the focussing coils. This relatively inexpensive and compact device is suitable for the irradiation of small material samples placed in high vacuum.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

System-on-chip integrated circuit technology applications on the DIII-D tokamak for multi-field measurements

Several mm-wave diagnostics on the DIII-D tokamak provide multi-scale and multi-dimensional measurements of plasma profile evolution and turbulence fluctuations. Mm-wave fusion plasma diagnostics that adopt system-on-chip integrated circuit technology can provide better space utilization, flexible installation, and improved sensitivity. In order to further extend this technology for additional fusion facilities with a higher toroidal magnetic field, V-band (55–75 GHz) and F-band (90–140 GHz) chips for Microwave Imaging Reflectometer (MIR) and Electron Cyclotron Emission Imaging (ECEI) instruments are developed and tested in the Davis Millimeter Wave Research Center (DMRC). Current measurement data show that correlation between these SoC-based diagnostic instruments with other state-of-the-art diagnostics enables co-located multi-field turbulence fluctuation measurement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A W:B{sub 4}C multilayer phase retarder for broadband polarization analysis of soft x-ray radiation

A W:B{sub 4}C multilayer phase retarder has been designed and characterized which shows a nearly constant phase retardance between 640 and 850 eV photon energies when operated near the Bragg condition. This freestanding transmission multilayer was used successfully to determine, for the first time, the full polarization vector at soft x-ray energies above 600 eV, which was not possible before due to the lack of suitable optical elements. Thus, quantitative polarimetry is now possible at the 2p edges of the magnetic substances Fe, Co, and Ni for the benefit of magnetic circular dichroism spectroscopy employing circularly polarized synchrotron radiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and construction of a point-contact spectroscopy rig with lateral scanning capability

The design and realization of a cryogenic rig for point-contact spectroscopy measurements in the needle-anvil configuration is presented. Thanks to the use of two piezoelectric nano-positioners, the tip can move along the vertical (z) and horizontal (x) direction and thus the rig is suitable to probe different regions of a sample in situ. Moreover, it can also form double point-contacts on different facets of a single crystal for achieving, e.g., an interferometer configuration for phase-sensitive measurements. For the later purpose, the sample holder can also host a Helmholtz coil for applying a small transverse magnetic field to the junction. A semi-rigid coaxial cable can be easily added for studying the behavior of Josephson junctions under microwave irradiation. The rig can be detached from the probe and thus used with different cryostats. The performance of this new probe has been tested in a Quantum Design PPMS system by conducting point-contact Andreev reflection measurements on Nb thin films over large areas as a function of temperature and magnetic field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CIV Vacuum Ultraviolet Fabry-Perot Interferometers for Transition-Region Magnetography

The vacuum ultraviolet region allows remote sensing of the upper levels of the solar atmosphere where the magnetic field dominates the physics. Obtaining an imaging interferometer that observes the transition region is the goal of this program. This paper gives a summary of our instrument development program (1998-2005) for a high-spectral-resolution, piezoelectric tunable Vacuum Ultraviolet Fabry-Perot Interferometer (VUV FPI) for obtaining narrow-passband images, magnetograms, and Dopplergrams of the transition region emission line of CN (155nm). A VUV interferometer will allow us to observe the magnetic field, flows, and heating events in the mid-transition region. The MSFC VUV FPI has measured values of FWHM approx. 9pm, FSR approx. 62pm, finesse approx. 5.3 and transmittance approx. 50% at 157nm. For the measurements, the University of Toronto's F2 eximer laser was used as an appropriate proxy for CIV 155nm. This has provided the first tunable interferometer with a FWHM compatible to VUV filter magnetograph.

Gary, G. Allen↗

R&D with NREL'S Nuclear Magnetic Resonance (NMR) Facility

NREL's state-of-the-art NMR Facility provides scientists the ability to analyze both solid and liquid samples on four NMR spectrometers. NREL's NMR instruments provide distinct capabilities for analyzing a variety of samples from biomass to plastics to battery components. NREL scientists can monitor reactions - even in real time - to further their understanding of the fundamental chemical processes that may drive the development of next-generation sustainable fuels, materials, and products.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Birkeland currents - Recent contributions from satellite magnetic field measurements

The important role that field-aligned Birkeland currents play in solar terrestrial coupling processes has been known from satellite observations for twenty years. Many satellite have been launched since the last Solar-Terrestrial Symposium with instruments capable of investigating the characteristics of Birkeland currents and their relationship to visible and UV auroral forms, particle precipitation, and convection flow patterns. An important result that has emerged is the close relationship between large-scale Birkeland currents and the orientation of the interplanetary magnetic field. These observations emphasize the fact that Birkeland currents are involved in a wide range of space plasma processes which range from small-scale ionospheric instabilities and irregularities to global scale energy coupling processes between the magnetosphere and solar wind.

Potemra, T. A.↗

CAST: An Inspiring Axion Helioscope ala Sikivie

CAST is a data taking axion helioscope using a recycled LHC test magnet, CERN's detector technology and cryogenics expertise. An imaging X-ray telescope improves substantially the detection sensitivity and axion-ID. Massive axion-like particles of the Kaluza-Klein type were first introduced to explain the paradox of the hot corona, which is even hotter at locations overlying magnetic spots. This is suggesting that the CAST detection principle might be at work there, but being somehow modified and performing better. Remarkably, the density profile of the Sun allows for resonance crossing (m{sub axion}c{sup 2{approx_equal}}h{omega}{sub plasma}), which axion helioscopes are aiming to reach. The restless Sun favours this occasionally even further. Then, such processes can give rise to a chimera of converted axions or the like, making the Sun appear, within known physics, as mysterious and unpredictable as it is. CAST axion limits were used to conclude also for the hidden sector paraphotons. This is then suggestive for novel helioscopes for exotica like paraphotons, chameleons, etc. Pierre Sikivie's pioneering idea was to use a magnetic field as a catalyst to transform particles from the dark sector to ours, and vice versa.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hanle effect as candidate for measuring magnetic fields in laboratory plasmas

Weak or turbulent magnetic fields are generally difficult to measure in laboratory plasmas. A new technique to address this problem may be based on the Hanle effect, used for magnetic field measurements in solar and stellar atmospheres. The effect consists in the modification of the polarization state of the resonance-line scattered radiation. It applies for magnetic field strengths for which the shift of magnetic sublevels remains comparable to the natural width of the sublevels. Experimental configurations and parameter ranges of applicability of a Hanle effect-based diagnostics technique are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A three-axis SQUID-based absolute vector magnetometer

We report on the development of a three-axis absolute vector magnetometer suited for mobile operation in the Earth’s magnetic field. It is based on low critical temperature dc superconducting quantum interference devices (LTS dc SQUIDs) with sub-micrometer sized cross-type Josephson junctions and exhibits a white noise level of about 10 fT/Hz{sup 1/2}. The width of superconducting strip lines is restricted to less than 6 μm in order to avoid flux trapping during cool-down in magnetically unshielded environment. The long-term stability of the flux-to-voltage transfer coefficients of the SQUID electronics is investigated in detail and a method is presented to significantly increase their reproducibility. We further demonstrate the long-term operation of the setup in a magnetic field varying by about 200 μT amplitude without the need for recalibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simple filtered repetitively pulsed vacuum arc plasma source

A very simple design of cathodic filtered vacuum arc plasma source is proposed. The source without filter has only four components and none of them require precise machining. The source operates in a repetitively pulsed regime, and for laboratory experiments it can be used without water cooling. Despite the simple construction, the source provides high ion current at the filter outlet reaching 2.5% of 400 A arc current, revealing stable operation in a wide pressure range from high vacuum to oxygen pressure up to more than 10{sup -2} mbar. There is no need in complicated power supply system for this plasma source, only one power supply can be used to ignite the arc, to provide the current for the arc itself, to generate the magnetic field in the filter, and provide its positive electric biasing without any additional high power resistance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Present status and plans for upgrading the Lujan neutron scattering center

The Lujan Center, part of the LANSCE accelerator complex at Los Alamos National Laboratory, operates a comprehensive neutron scattering facility for the U.S. Department of Energy that serves approximately 300 users per year. This paper will discuss the current instruments and status of the facility and also focus on the plans for a major upgrade of the Center including new instruments and enhancements to specific existing instruments. The instrument suite currently includes two reflectometers (one with full polarization), an engineering diffraction machine, a diffractometer specialized to pair-distribution analysis, 2 general purpose powder diffractometers, and 2 inelastic spectrometers. To complement these spectrometers, a full range of pressure, temperature, and magnetic field sample environments is available for users. As part of the planning for a forthcoming enhancement of Lujan Center, a series of workshops have been held over the past year to encourage user input to the design for new instruments as well as major upgrades of existing machines. Many of the planned facilities are designed to take advantage of the Lujan Center 20 Hz pulse repetition rate and cold source moderators, both of which are beneficial for high-resolution instruments using long neutron wavelengths.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design and characterization of a novel toroidal split-ring resonator

The design and characterization of a novel toroidal split-ring resonator (SRR) are described in detail. In conventional cylindrical SRRs, there is a large magnetic flux within the bore of the resonator. However, there also exists a non-negligible magnetic flux in the free space surrounding the resonator. The energy losses associated with this radiated power diminish the resonator’s quality factor. In the toroidal SRR, on the other hand, the magnetic field lines are strongly confined within the bore of the resonator resulting in high intrinsic quality factors and stable resonance frequencies without requiring additional electromagnetic shielding. This paper describes the design and construction of a toroidal SRR as well as an experimental investigation of its cw response in the frequency-domain and its time-domain response to a rf pulse. Additionally, the dependence of the toroidal SRR’s resonant frequency and quality factor on the strength of inductive coupling to external circuits is investigated both theoretically and experimentally.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three axis vector magnet set-up for cryogenic scanning probe microscopy

We describe a three axis vector magnet system for cryogenic scanning probe microscopy measurements. We discuss the magnet support system and the power supply, consisting of a compact three way 100 A current source. We obtain tilted magnetic fields in all directions with maximum value of 5T along z-axis and of 1.2T for XY-plane magnetic fields. We describe a scanning tunneling microscopy-spectroscopy (STM-STS) set-up, operating in a dilution refrigerator, which includes a new high voltage ultralow noise piezodrive electronics and discuss the noise level due to vibrations. STM images and STS maps show atomic resolution and the tilted vortex lattice at 150 mK in the superconductor β-Bi{sub 2}Pd. We observe a strongly elongated hexagonal lattice, which corresponds to the projection of the tilted hexagonal vortex lattice on the surface. We also discuss Magnetic Force Microscopy images in a variable temperature insert.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Positive-ion accelerator mass spectrometry at ATLAS: Peaks and pits

Electron Cyclotron Resonance (ECR) ion sources and the production of multiple-charge positive ions with high efficiency in combination with a heavy-ion accelerator have opened the way to an alternative and complementary version of accelerator mass spectrometry (AMS). A notable strength of positive-ion over traditional AMS is the capability of ultra-high sensitivity detection of radioactive isotopes of noble gases, in particular 37 Ar (t 1/2 = 35 d) and 39 Ar (269 y). The complete dissociation of molecular ions in the ECR and in particular of hydride ions of neighboring stable isotopes results in superior isotopic separation. However, the use of high charge states, necessary for acceleration to high energy, entails the existence of severe transmission degeneracies with stable ions having nearly equal mass-to-charge ratios, in addition to that of stable isobaric ions. Separation or discrimination of these parasitic ions require powerful and sophisticated dispersive systems at detection stage. In conclusion, we review here work performed and in progress at the ATLAS facility of Argonne National Laboratory (ANL) where an ECR ion source, a Radio-Frequency Quadrupole (RFQ), a superconducting linear accelerator and a Gas-Filled Magnet (GFM) are used as an AMS setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of silicon photomultipliers and their applications to GlueX calorimetry

The GlueX experiment is a photoproduction experiment in Hall D at Jefferson Lab that is being commissioned for use with the new 12 GeV accelerator. The purpose of the experiment is to search for Hybrid mesons, which are mesons with quark and gluon degrees of freedom. The barrel calorimeter of GlueX is instrumented with 4000 large-area (1.2 × 1.2 cm{sup 2}) silicon photomultipliers (SiPMs). These photon sensors have properties similar to vacuum photomultipliers, but are unaffected by high magnetic fields. In our experiment they operate in magnetic fields exceeding 1T. After extensive tests with a variety of sensors, we chose the S12045(X) custom SiPM arrays manufactured by Hamamatsu Corporation, also known as multi-pixel photon counters (MPPCs). We will give an overview of this new technology as well as the experience gained during two commissioning periods with beam.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Recent studies of magnetic canopies

Two current studies are described which stem from Giovanelli's seminal studies of the spreading of chromospheric fields near active regions and active-region network. First, improved observational techniques are described for obtaining magnetograms in the Ca II 8542 A, Fe I 8688 A, and C I 9111 A lines which at least in principle allow for more accurate treatment of instrumental noise and allow better inference of field orientation. Second, a generalized response function is developed for calculating theoretical magnetograph signals from arbitrary line-of-sight variations of magnetic field, and initial applications to two-dimensional, potential-field models of network fields are described. Preliminary indications are that potential-field models can better explain the presence of low-lying, diffuse horizontal fields than can thin flux-tube models, but fail to predict a differential response between the different lines.

Jones, H. P.↗