Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Liquid flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Anomaly Detection in Test Equipment via Sliding Mode Observers

Nonlinear observers were originally developed based on the ideas of variable structure control, and for the purpose of detecting disturbances in complex systems. In this anomaly detection application, these observers were designed for estimating the distributed state of fluid flow in a pipe described by a class of advection equations. The observer algorithm uses collected data in a piping system to estimate the distributed system state (pressure and velocity along a pipe containing liquid gas propellant flow) using only boundary measurements. These estimates are then used to further estimate and localize possible anomalies such as leaks or foreign objects, and instrumentation metering problems such as incorrect flow meter orifice plate size. The observer algorithm has the following parts: a mathematical model of the fluid flow, observer control algorithm, and an anomaly identification algorithm. The main functional operation of the algorithm is in creating the sliding mode in the observer system implemented as software. Once the sliding mode starts in the system, the equivalent value of the discontinuous function in sliding mode can be obtained by filtering out the high-frequency chattering component. In control theory, "observers" are dynamic algorithms for the online estimation of the current state of a dynamic system by measurements of an output of the system. Classical linear observers can provide optimal estimates of a system state in case of uncertainty modeled by white noise. For nonlinear cases, the theory of nonlinear observers has been developed and its success is mainly due to the sliding mode approach. Using the mathematical theory of variable structure systems with sliding modes, the observer algorithm is designed in such a way that it steers the output of the model to the output of the system obtained via a variety of sensors, in spite of possible mismatches between the assumed model and actual system. The unique properties of sliding mode control allow not only control of the model internal states to the states of the real-life system, but also identification of the disturbance or anomaly that may occur.

Solano, Wanda M.↗

Development of In-Can Melting Process Applied to Vitrification of High Activity Waste Solutions (HAWS): Glass characterizations and process tests results - 12442

The CEA has selected vitrification for specific High-Activity nuclear Waste Solutions (HAWS) containing large quantities of salts. This choice has led the CEA Marcoule to develop a compact 'in-can' batch melting process in which the melting pot is disposable and serves as the primary canister for the solidified glass. This process is particularly suitable for the treatment of small waste quantities (less than 10 m{sup 3} per year) and low flow rates (5 to 10 L/h) which do not justify the use of a Cold Crucible Induction Melter. The unit capacity is approximately one hundred kilograms of glass a week operating alternately between feeding during the day and surveillance at night. In order to be fully representative of the glove box to be implemented, a new nonradioactive pilot-scale unit in which the core process (furnace and dust scrubber) is completely enclosed with glove box simulation was built at CEA Marcoule in 2008. The equipment includes all the systems and components necessary to perform full-scale tests: feed system, furnace and complete off-gas treatment system. The nominal tests were performed in 2009 and 2010 to verify that no problems arose in vitrifying solutions under the specified conditions. Two different liquid feeds representatives of the current HAWS stored and future solutions were used. The transient runs were carried out in this facility in 2010. Their objectives were to validate the glass product with different operating conditions and to determine optimum parameters for transient phases such as decreased volatility during standby phases. Finally, all the material obtained under nominal conditions or different operating conditions (e.g. initial glass frit quantity, standby temperature or restart procedure of feeding after night surveillance) have been characterized and described. The impact of transient phases on the process is then discussed in terms of volatility, thermal balance, etc., and compared with nominal tests results. Off-gas treatment system (OGTS) assessments determined preliminary decontamination factors for the OGTS components and allowed comparison between the two types of solutions and for different operating parameters. Since 2005 CEA Marcoule has been developing an 'in-can melting' vitrification process for specific High Activity Nuclear Waste Solutions. The tests carried out to date have validated the feasibility of this process and confirmed the direct vitrification option in which the liquid and solid feed streams are supplied directly to a disposable melting pot. CEA Marcoule began process qualification testing in 2009 in a new facility using equipment representative of the devices that will be installed in a glove box. The nominal mode tests performed in 2009 and 2010 were used to determine nominal operating conditions for the process: - a nominal process temperature of 1100 deg. C; - a maximum glass production rate of 5 kg/h; - a liquid feed solution flow rate of 5 L/h or less if the glass production rate exceeds the preceding maximum value; - a liquid recycle rate of 0.5 L/h for a nominal solution feed rate 5 L/h. They also produced glass samples generally meeting our expectations, and allowed us to measure the characteristic properties (viscosity, density, thermal conductivity, chemical durability). The first test of transient operation in 2010 yielded glass consistent with expectations and showed that reducing the temperature had no significant effect on the volatility of the constituent elements. However, a significant impact on the release of elements at the beginning of the test was observed with a larger initial quantity of glass frit on startup. The process qualification program will now continue with tests of degraded operating modes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Time-resolved measurements of liquid–vapor thermal interactions throughout the full life-cycle of sliding bubbles at subcooled flow boiling conditions

The local thermal response of the liquid phase to the presence of sliding bubbles was measured with an infrared camera in subcooled flow-boiling conditions. These measurements were complemented with two high-speed cameras to capture the corresponding bubbles’ dynamics. The liquid–vapor interactions were captured in detail over the full life-cycle of sliding bubbles. Four distinctive phases for the bubble life-cycle were identified: A) Spherical bubble growth with strong attachment, B) Deformed bubble growth with weak attachment, C) Detachment with hot liquid quenching, and D) Cold liquid quenching. Here, to the best of the authors’ knowledge, it is the first time that the “detachment with hot liquid quenching phase has been observed. This phase is characterized by a “hot” thermal footprint during the bubble detachment process. It is believed that this footprint is constituted partially from hot liquid released during the condensation of the recently detached bubble, and from released hot fluid previously collected by the bubble during sliding. In addition, this work reveals that using traditional high-speed visualization techniques (side-view camera only) can lead to an underestimation of approximately 40% of the actual bubble–wall contact diameter (dc) which was inferred from the infrared camera measurements.

42 ENGINEERING↗

Gas-liquid Phase Distribution and Void Fraction Measurements Using the MRI

We used a permanent-magnet MRI system to estimate the integral and spatially- and/or temporally-resolved void-fraction distributions and flow patterns in gas-liquid two-phase flows. Air was introduced at the bottom of the stagnant liquid column using an accurate and programmable syringe pump. Air flow rates were varied between 1 and 200 ml/min. The cylindrical non-conducting test tube in which two-phase flow was measured was placed in a 2.67 kGauss MRI with MRT spectrometer/imager. Roughly linear relationship has been obtained for the integral void-fraction, obtained by volume-averaging of the spatially-resolved signals, and the air flow rate in upward direction. The time-averaged spatially-resolved void fraction has also been obtained for the quasi-steady flow of air in a stagnant liquid column. No great accuracy is claimed as this was an exploratory proof-of-concept type of experiment. Preliminary results show that MRI a non-invasive and non-intrusive experimental technique can indeed provide a wealth of different qualitative and quantitative data and is especially well suited for averaged transport processes in adiabatic and diabatic multi-phase and/or multi-component flows.

Daidzic, N. E.↗

Refill Friction Stir Spot Welding Dissimilar Al/Mg Alloys

Dissimilar Al/Mg alloys were joined by refill friction stir spot welding (RFSSW) in this work. The effect of sleeve plunge depth on microstructure and mechanical properties of the joints was studied. The results showed that sound joint can be obtained at sleeve plunge depth of 2.4 mm. Intermetallic compounds (IMCs) layer, formed by the liquid eutectic phase, were observed at both the sleeve-affected zone and joint center. The IMC at the pin-affected zone was thicker than that at the sleeve-affected zone because of its flow characteristic. Less liquid eutectic phase formed during RFSSW when joint using Mg as the upper sheet because the oxide layer on the Al sheet was hard to break, resulting to thinner IMC layer. The maximum load of 3.6 kN was obtained at 2.6 mm when the Al alloys served as the upper sheet, and the maximum failure of 3.6 kN was also obtained at 2.4 mm when the Mg alloys served as the upper sheet. The RFSSW joint presented shear fracture mode. The XRD patterns showed that the IMC of Al{sub 3}Mg{sub 2} and Al{sub 12}Mg{sub 17} formed inside the joint.

36 MATERIALS SCIENCE↗

Flow and evaporation in single micrometer and nanometer scale pipes

We report measurements of pressure driven flow of fluids entering vacuum through a single pipe of micrometer or nanometer scale diameter. Nanopores were fabricated by etching a single ion track in polymer or mica foils. A calibrated mass spectrometer was used to measure the flow rates of nitrogen and helium through pipes with diameter ranging from 10 μm to 31 nm. The flow of gaseous and liquid nitrogen was studied near 77 K, while the flow of helium was studied from the lambda point (2.18 K) to above the critical point (5.2 K). Flow rates were controlled by changing the pressure drop across the pipe in the range 0–31 atm. When the pressure in the pipe reached the saturated vapor pressure, an abrupt flow transition was observed. A simple viscous flow model is used to determine the position of the liquid/vapor interface in the pipe. The observed mass flow rates are consistent with no slip boundary conditions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Control of Melt Conversion Using Traveling Magnetic Fields

An axisymmetric traveling magnetic wave induces a meridional base flow in a cylindrical zone of an electrically conducting liquid. This remotely induced flow can be conveniently controlled, in magnitude and direction, and can have benefits for crystal growth applications. In particular, it can be used to significantly offset natural convection. Theoretical basics of this new technological method are presented.

Mazurruk, Konstantin↗

Control of Melt Convection Using Traveling Magnetic Fields

An axisymmetric traveling magnetic wave induces a meridional base flow in a cylindrical zone of an electrically conducting liquid. This remotely induced flow can be conveniently controlled, in magnitude and direction, and can have benefits for crystal growth applications. In particular, it can be used to offset natural convection. Theoretical basics of this new technological method are presented.

Mazuruk, Konstantin↗

Convective Flow Induced by Localized Traveling Magnetic Fields

An axisymmetric traveling magnetic field induces a meridional base flow in a cylindrical zone of an electrically conducting liquid. This remotely induced flow can be conveniently controlled, in magnitude and direction, and can have benefits for crystal growth applications. In particular, it can be used to offset natural convection. For long vertical cylinders, non-uniform and localized in the propagating direction, magnetic fields are required for this purpose. Here we investigate a particular form of this field, namely that induced by a set of a few electric current coils. An order of magnitude reduction of buoyancy convection is theoretically demonstrated for a vertical Bridgman crystal growth configuration.

Mazuruk, Konstantin↗

On the inhomogeneity of the transition surface layer of the solid core of the earth

Different geophysical data and conclusions of theoretical models, which can give information about the behavior of the solid and liquid cores of the Earth as well as about the existence of a transition layer as a temperature-hysteresis region at a relatively weak first-order phase transition, are compared. It is concluded that liquid inclusions inevitably exist in this region; these inclusions are involved (due to the complex convective processes occurring in the liquid core) in the transport of light materials from some areas of the solid-core surface. The porosity and permeability of the transition layer determine the seismic acoustic inhomogeneities in these areas, which contact the convective flows in the liquid core. In particular, this explains the well-known 'east-west' effect. Obviously, the model of the crystalline core is not the only possible alternative for a model of a core with a metallic glasslike structure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Computation of Space Shuttle high-pressure cryogenic turbopump ball bearing two-phase coolant flow

A homogeneous two-phase fluid flow model, implemented in a three-dimensional Navier-Stokes solver using computational fluid dynamics methodology is described. The application of the model to the analysis of the pump-end bearing coolant flow of the high-pressure oxygen turbopump of the Space Shuttle main engine is studied. Results indicate large boiling zones and hot spots near the ball/race contact points. The extent of the phase change of the liquid oxygen coolant flow due to the frictional and viscous heat fluxes near the contact areas has been investigated for the given inlet conditions of the coolant.

Chen, Yen-Sen↗

Some problems in relativistic thermodynamics

The relativistic equations of state for ideal and real gases, as well as for various interface regions, have been derived. These dependences help to eliminate some controversies in the relativistic thermodynamics based on the special theory of relativity. It is shown, in particular, that the temperature of system whose velocity tends to the velocity of light in vacuum varies in accordance with the Ott law T = T{sub 0}/{radical}1 - v{sup 2}/c{sup 2}. Relativistic dependences for heat and mass transfer, for Ohm's law, and for a viscous flow of a liquid have also been derived.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Module for Oxygenating Water without Generating Bubbles

A module that dissolves oxygen in water at concentrations approaching saturation, without generating bubbles of oxygen gas, has been developed as a prototype of improved oxygenators for water-disinfection and water-purification systems that utilize photocatalyzed redox reactions. Depending on the specific nature of a water-treatment system, it is desirable to prevent the formation of bubbles for one or more reasons: (1) Bubbles can remove some organic contaminants from the liquid phase to the gas phase, thereby introducing a gas-treatment problem that complicates the overall water-treatment problem; and/or (2) in some systems (e.g., those that must function in microgravity or in any orientation in normal Earth gravity), bubbles can interfere with the flow of the liquid phase. The present oxygenation module (see Figure 1) is a modified version of a commercial module that contains >100 hollow polypropylene fibers with a nominal pore size of 0.05 m and a total surface area of 0.5 m2. The module was originally designed for oxygenation in a bioreactor, with no water flowing around or inside the tubes. The modification, made to enable the use of the module to oxygenate flowing water, consisted mainly in the encapsulation of the fibers in a tube of Tygon polyvinyl chloride (PVC) with an inside diameter of 1 in. (approx.=25 mm). In operation, water is pumped along the insides of the hollow fibers and oxygen gas is supplied to the space outside the hollow tubes inside the PVC tube. In tests, the pressure drops of water and oxygen in the module were found to be close to zero at water-flow rates ranging up to 320 mL/min and oxygen-flow rates up to 27 mL/min. Under all test conditions, no bubbles were observed at the water outlet. In some tests, flow rates were chosen to obtain dissolved-oxygen concentrations between 25 and 31 parts per million (ppm) . approaching the saturation level of approx.=35 ppm at a temperature of 20 C and pressure of 1 atm (approx.=0.1 MPa). As one would expect, it was observed that the time needed to bring a flow of water from an initial low dissolved-oxygen concentration (e.g., 5 ppm) to a steady high dissolved-oxygen concentration at or near the saturation level depends on the rates of flow of both oxygen and water, among other things. Figure 2 shows the results of an experiment in which a greater flow of oxygen was used during the first few tens of minutes to bring the concentration up to approx.=25 ppm, then a lesser flow was used to maintain the concentration.

Gonzalez-Martin, Anuncia↗

Heat Transfer Enhancement in Cryogenic Quenching Process

This paper reports a heat transfer advancement in the cryogenic quenching process. An experiment was performed to evaluate the enhancement of quenching heat transfer by the use of metal tubes with low thermal conductivity coating layers. Four coating thicknesses with various coolant mass flow rates of liquid nitrogen were investigated. The results indicated that the tube inner surface coating greatly enhanced the quenching efficiency. The quenching efficiency was found to increase with increasing number of coating layers, and the efficiency also increased with decreasing mass flow rates. In general, the efficiencies cover a range between 40.6% and 80%. Comparing to the bare surface case, the percentage increase in the quenching efficiency was the minimum at 4.2% for a single coated layer at the highest flow rate and the maximum of 109.1% for four coated layers at the lowest flow rate. The coated tubes could save up to 53% in the amount of cryogen consumption.

Surface coating↗

Capture probe

A system for sampling a sample material includes a device for directing sample into a capture probe. A probe includes an outer probe housing having an open end. A liquid supply conduit has an outlet positioned to deliver liquid to the open end. An exhaust conduit removes liquid from the open end of the housing. The liquid supply conduit can be connectable to a liquid supply for delivering liquid at a first volumetric flow rate to the open end of the housing. A liquid exhaust system can be in fluid connection with the liquid exhaust conduit for removing liquid from the liquid exhaust conduit at a second volumetric flow rate, which exceeds the first volumetric flow rate such that gas with sample is withdrawn with the liquid.

36 MATERIALS SCIENCE↗

Capture probe

A system for sampling a sample material includes a device for directing sample into a capture probe. A probe includes an outer probe housing having an open end. A liquid supply conduit has an outlet positioned to deliver liquid to the open end. An exhaust conduit removes liquid from the open end of the housing. The liquid supply conduit can be connectable to a liquid supply for delivering liquid at a first volumetric flow rate to the open end of the housing. A liquid exhaust system can be in fluid connection with the liquid exhaust conduit for removing liquid from the liquid exhaust conduit at a second volumetric flow rate, which exceeds the first volumetric flow rate such that gas with sample is withdrawn with the liquid.

42 ENGINEERING↗