Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Integrated Assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Dixie Valley Engineered Geothermal System Exploration Methodology Project, Baseline Conceptual Model Report

The Engineered Geothermal System (EGS) Exploration Methodology Project is developing an exploration approach for EGS through the integration of geoscientific data. The Project chose the Dixie Valley Geothermal System in Nevada as a field laboratory site for methodology calibration purposes because, in the public domain, it is a highly characterized geothermal system in the Basin and Range with a considerable amount of geoscience and most importantly, well data. The overall project area is 2500km2 with the Calibration Area (Dixie Valley Geothermal Wellfield) being about 170km2. The project was subdivided into five tasks (1) collect and assess the existing public domain geoscience data; (2) design and populate a GIS database; (3) develop a baseline (existing data) geothermal conceptual model, evaluate geostatistical relationships, and generate baseline, coupled EGS favorability/trust maps from +1km above sea level (asl) to -4km asl for the Calibration Area at 0.5km intervals to identify EGS drilling targets at a scale of 5km x 5km; (4) collect new geophysical and geochemical data, and (5) repeat Task 3 for the enhanced (baseline + new ) data. Favorability maps were based on the integrated assessment of the three critical EGS exploration parameters of interest: rock type, temperature and stress. A complimentary trust map was generated to compliment the favorability maps to graphically illustrate the cumulative confidence in the data used in the favorability mapping. The Final Scientific Report (FSR) is submitted in two parts with Part I describing the results of project Tasks 1 through 3 and Part II covering the results of project Tasks 4 through 5 plus answering nine questions posed in the proposal for the overall project. FSR Part I presents (1) an assessment of the readily available public domain data and some proprietary data provided by Terra-Gen Power, LLC, (2) a re-interpretation of these data as required, (3) an exploratory geostatistical data analysis, (4) the baseline geothermal conceptual model, and (5) the EGS favorability/trust mapping. The conceptual model presented applies to both the hydrothermal system and EGS in the Dixie Valley region. FSR Part II presents (1) 278 new gravity stations; (2) enhanced gravity-magnetic modeling; (3) 42 new ambient seismic noise survey stations; (4) an integration of the new seismic noise data with a regional seismic network; (5) a new methodology and approach to interpret this data; (5) a novel method to predict rock type and temperature based on the newly interpreted data; (6) 70 new magnetotelluric (MT) stations; (7) an integrated interpretation of the enhanced MT data set; (8) the results of a 308 station soil CO2 gas survey; (9) new conductive thermal modeling in the project area; (10) new convective modeling in the Calibration Area; (11) pseudo-convective modeling in the Calibration Area; (12) enhanced data implications and qualitative geoscience correlations at three scales (a) Regional, (b) Project, and (c) Calibration Area; (13) quantitative geostatistical exploratory data analysis; and (14) responses to nine questions posed in the proposal for this investigation. Enhanced favorability/trust maps were not generated because there was not a sufficient amount of new, fully-vetted (see below) rock type, temperature, and stress data. The enhanced seismic data did generate a new method to infer rock type and temperature. However, in the opinion of the Principal Investigator for this project, this new methodology needs to be tested and evaluated at other sites in the Basin and Range before it is used to generate the referenced maps. As in the baseline conceptual model, the enhanced findings can be applied to both the hydrothermal system and EGS in the Dixie Valley region.

15 GEOTHERMAL ENERGY↗

Dynamic Model Agnostic Reliability Evaluation of Machine-Learning Models Integrated in Instrumentation & Control Systems

In recent years, the field of machine learning (ML), specifically neural networks, has grown significantly and has spurred research in its applicability to digital instrumentation and control systems (DI&C). While ML models have shown promise in operational contexts, the trustworthiness of using such algorithms has not been adequately assessed. Failures of ML integrated systems are not well understood, and the lack of comprehensive risk modeling can degrade the trustworthiness in these systems. In recent reports by the National Institute for Standards and Technology (NIST) [1] and the Nuclear Regulatory Commission (NRC) [2], they indicate that trustworthiness in ML is a critical barrier and will play a vital role in the safe, accountable, and secure operation of intelligent systems. Thus, in this work, we demonstrate a dynamic model-agnostic method to quantify the relative reliability of AI/ML predictions by incorporating out-of-distribution (OOD) detection on the training dataset. It is well documented that most ML algorithms excel at interpolation (or near-interpolation) tasks but experience significant performance degradation at extrapolation. The method, referenced as the Laplacian distributed decay for reliability (LADDR), determines the difference between the operational and training datasets which can used to the relative reliability of AI/ML predictions. LADDR is then demonstrated on a feedforward neural network based digital twin used for the prediction of safety significant factors during a loss-of-flow transient. LADDR is used to demonstrate how training data can be used as evidence to support the relative reliability of ML/AI predictions enhancing the overall trustworthiness of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Socioeconomic Impact Evaluation for Near Real-time Flood Detection in the Lower Mekong River Basin

Flood events pose a severe threat to communities in the Lower Mekong River Basin. The combination of population growth, urbanization, and economic development exacerbate the impacts of these events. Flood damage assessments, critical for understanding the effects of flooding on the local population and informing decision-makers about future risks, are frequently used to quantify the economic losses due to storms. Remote sensing systems provide a valuable tool for monitoring flood conditions and assessing their severity more rapidly than traditional post-event evaluations. The frequency and severity of extreme flood events are projected to increase, further highlighting the need for improved flood monitoring and impact analysis. In this study we integrate a socioeconomic damage assessment model with a near real-time flood remote sensing and decision support tool (NASA's Project Mekong). Direct damages to populations, infrastructure, and land cover are assessed using the 2011 Southeast Asian flood as a case study. Improved land use/land cover and flood depth assessments result in rapid loss estimates throughout the Mekong River Basin. Results suggest that rapid initial estimates of flood impacts can provide valuable information to governments, international agencies, and disaster responders in the wake of extreme flood events.

Mekong Basin↗

Multi-parametric approach towards the assessment of radon and thoron progeny exposures

Conventionally, the dosimetry is carried out using radon and thoron gas concentration measurements and doses have been assigned using assumed equilibrium factors for the progeny species, which is inadequate pertaining to the variations in equilibrium factors and possibly due to significant thoron. In fact, since the true exposures depend upon the intricate mechanisms of progeny deposition in the lung, therefore an integrated approach for the assessment of progeny is essential. In this context, the recently developed deposition based progeny concentration measurement techniques (DTPS: Direct Thoron progeny sensors and DRPS: Direct Radon progeny sensors) appear to be best suited for radiological risk assessments both among occupational workers and general study populations. DTPS and DRPS consist of aluminized mylar mounted LR115 type passive detectors, which essentially detects the alpha particles emitted from the deposited progeny atoms on the detector surface. It gives direct measure of progeny activity concentrations in air. DTPS has a lower limit of detection limit of 0.1 Bq/m{sup 3} whereas that for DRPS is 1 Bq/m{sup 3}, hence are perfectly suitable for indoor environments. These DTPS and DRPS can be capped with 200-mesh type wire-screen to measure the coarse fraction of the progeny concentration and the corresponding coarse fraction deposition velocities as well as the time integrated fine fraction. DTPS and DRPS can also be lodged in an integrated sampler wherein the wire-mesh and filter-paper are arranged in an array in flow-mode, to measure the fine and coarse fraction concentration separately and simultaneously. The details are further discussed in the paper.

61 RADIATION PROTECTION AND DOSIMETRY↗

Failure Assessments for MQXF Magnet Support Structure with a Graded Approach

The High-Luminosity Large Hadron Collider (HLLHC) upgrade requires new quadrupoles, MQXF, to replace the present LHC inner triplets. The MQXFA magnet is the first prototype that has a 150 mm aperture and uses Nb 3 Sn superconducting technology in a 4.2 m magnetic length structure. The support structure design of the MQXFA magnet is based on the bladder-and-key technology, where a relatively low pre-stress at room temperature is increased to the final preload targets during the cool-down by the differential thermal contraction of the various components. The magnet support structure components experience different load levels from pre-load to cool-down and excitation. Consequently, a few parts experience high stresses that may cause localized plastic deformations or internal fracture development. The concept presented in this paper for the failure assessment of support structures integrates nonlinear finite element analysis with detailed sub-models and fracture mechanics into an advanced engineering tool. The nonlinear FE solutions enable estimations of the structural response to the given loads, and the advanced fracture analysis with failure assessment diagram (FAD) assesses the structure safety index of results obtained from the FE model. The study describes how the MQXFA shell end segments are being optimized based on the failure analyses.

43 PARTICLE ACCELERATORS↗

A novel methodology to integrate outcomes regarding perioperative pain experience into a composite score: Prediction model development and validation

Abstract Background An integrated score that globally assesses perioperative pain experience and rationally weights each component has not yet been developed. Methods A development dataset specific to adult Chinese patients undergoing orthopaedic surgery was obtained from PAIN OUT (1985 qualified patients of 2244). A more recent validation dataset obeying the same conditions was obtained from the Chinese Anaesthesia Shared‐database Platform (1004 qualified patients of 1032). Outcomes were assessed using the International Pain Outcomes Questionnaire (IPO‐Q), which comprises key patient‐level outcomes of perioperative pain management, including pain experience and perceptions of care. Using principal component analysis and regression models, a composite score (CS) was inferred to integrate pain experience. The discrimination of the CS for dissatisfaction and desire for more pain treatment was compared with that of the worst pain score. Results A CS was developed from the 12 items of the IPO‐Q regarding pain experience. The weight for calculating the CS was worst pain 11, least pain 17, time spent in severe pain 11, interference with activity in bed 9, interference with breathing deeply or coughing 10, interference with sleep 9, anxiety 12, helplessness 12, nausea 0, drowsiness 2, itch 5 and dizziness 2. In external validation, the CS indicated superior discrimination to the worst pain in predicting dissatisfaction ( p < 0.001) and desire for more pain treatment ( p < 0.001). Conclusions This study introduced a methodology to integrate outcomes regarding perioperative pain experience into a CS, which was based on the weight of each item. Significance This novel methodology sheds additional light on the riveting issue of carefully integrating several measures into a composite endpoint, which may be useful for quality improvement purposes when addressing the impact of a change in clinical practice.

Jiang, Bailin↗

Development of an Assessment Method for Radiation Exposure from NORM in Construction Materials - 19032

Once radiological impact is usually considered to be related to nuclear energy accidents and atomic bombs, most of the research on radiation protection has been focused on artificial radionuclides and radioactive waste. Less attention had been given to radiation exposure due to the presence of naturally occurring radioactive materials in raw materials usually considered as not radioactive and used in manufacturing of many building materials. At national level, radiological data from building materials is not available as the control of building materials regarding the content of naturally occurring radionuclides is addressed for the first time in the EU Directive 2013/59/EURATOM. At international level the research developed is largely incomplete: data on the activity concentration measurements of Ra-226, Th-232 and K-40 in building materials used in the construction industry in the EU is non-statistically representative. The data collected are not enough to have an idea of the European situation, but they confirm high concentration of Ra-226, Th-232 and K-40, in some cases. Moreover, most of the research studies carried out in the EU are based on the assessment of the activity concentration index, which was derived for practical monitoring purposes to identify whether a dose criterion is met; to be used only as a screening tool for identifying materials which might be of concern. The dose criterion considers only effective dose due to γ-radiation, but population at home is also exposed to Rn-222 (and Rn-220) from soil, water and building material itself, sometimes to β radiation from superficial materials, and even to Cs-137 from some types of wood. The indoors exposure can be actually much higher than the value assessed with the dose criterion method. Also, in most cases toxic and radioactive components are inseparably. Therefore, all technical questions related to the toxic part of these materials should be addressed: an integrated approach is needed to assess the impacts of using these materials (new materials, recyclates and by-products). Until recently, radiation from natural sources seemed both unremarkable and unalterable - a background phenomenon. It is now known that doses from natural sources and in particular, decay products of radon can be remarkably high within houses in some areas. Therefore, concerning exposure to natural radiation sources, special provisions have been laid down in the EU Directive 1996/28 EURATOM. Still, the radiological evaluation of building materials was not mandatory in this Directive. The most recent EU Directive 2013/59/EURATOM brings some changes concerning the exposure to natural occurring radioactive materials but the previous screening method was kept. An effective dose of 1 mSv/year was set, as a basis for the exposure to radionuclides of natural origin (except for radon). This work seeks to develop an integrated radiological and chemical-mineralogical assessment methodology for realistic exposure scenarios concerning different types of raw materials, by-products and recyclates and used as building materials. The methodology includes the characterization of selected materials accounting for radiological exposure - calculation of effective dose; toxicity assessment - determination of chemical composition and leaching tests, study of changes in the microstructure and consequently in the radon emanation coefficient. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

On the Assessment of Acoustic Scattering and Shielding by Time Domain Boundary Integral Equation Solutions

Based on the time domain boundary integral equation formulation of the linear convective wave equation, a computational tool dubbed Time Domain Fast Acoustic Scattering Toolkit (TD-FAST) has recently been under development. The time domain approach has a distinct advantage that the solutions at all frequencies are obtained in a single computation. In this paper, the formulation of the integral equation, as well as its stabilization by the Burton-Miller type reformulation, is extended to cases of a constant mean flow in an arbitrary direction. In addition, a "Source Surface" is also introduced in the formulation that can be employed to encapsulate regions of noise sources and to facilitate coupling with CFD simulations. This is particularly useful for applications where the noise sources are not easily described by analytical source terms. Numerical examples are presented to assess the accuracy of the formulation, including a computation of noise shielding by a thin barrier motivated by recent Historical Baseline F31A31 open rotor noise shielding experiments. Furthermore, spatial resolution requirements of the time domain boundary element method are also assessed using point per wavelength metrics. It is found that, using only constant basis functions and high-order quadrature for surface integration, relative errors of less than 2% may be obtained when the surface spatial resolution is 5 points-per-wavelength (PPW) or 25 points-per-wavelength squared (PPW2).

Hu, Fang Q.↗

Performance Comparison of Circular and Spherical Error Probable Estimators

This report compares the performance of three Circular Error Probable (CEP) estimators: the Grubbs-Patnaik estimator, a new, non-iterative, radial-integration estimator, and a median estimator. It also compares the performance of two Spherical Error Probable (SEP) estimators. The performance of each estimator is assessed in terms of bias, uncertainty, robustness, and computational complexity. Robustness is evaluated with respect to outliers, variations in the underlying statistical distribution characterizing munition impact positions, and impact-position measurement errors. The performance assessments indicate the radial-integration and Grubbs-Patnaik estimators perform nearly identically providing the statistical distribution of impact-position coordinates is jointly normal with zero means. In that case, both estimators outperform the median estimator by about 2% relative to the true CEP in terms of estimator uncertainty. The bias performance of the radial-integration and median estimators is close to zero for jointly normal impacts, however, the Grubbs-Patnaik estimator can be significantly biased for jointly normal impacts with non-zero means. When the statistical distribution characterizing impact positions is known, but not jointly normal, the radial-integration estimator is superior. In this case, the median estimator also outperforms the Grubbs-Patnaik estimator but is not quite as good as the radial-integration estimator. If the statistical distribution characterizing impacts is unknown and not jointly normal, or if distribution parameters are difficult or impractical to estimate, or if test data is corrupted with outliers, then the median estimator dramatically outperforms the other estimators, especially in terms of estimation bias. Unexpectedly, measurement noise did not significantly degrade the performance of any of the estimators, except for cases with signal to noise ratios less than five. Although the Grubbs-Patnaik estimator has remained the gold standard for CEP estimation for over half a century, the performance assessments indicate the new, non-iterative, radial-integration estimator and the median estimator offer significant advantages and, in most practical real-world conditions, are superior estimators. These estimators are also useful for SEP estimation whereas the Grubbs-Patnaik estimator does not extend to three dimensions.

97 MATHEMATICS AND COMPUTING↗

Dashboard for Marine Energy Site Assessment and Monitoring

The marine energy (ME) industry presently relies upon fragmented site assessment solutions that require high resource expenditure for deployment at each site and do not leverage the wealth of readily available tools and information. A wave energy resource assessment dashboard, currently in development, will substantially improve siting, permitting, operations, and maintenance of ME projects by providing an integrated solution that is a one-stop-shop for a developer’s needs. The Site Energy Assessment and MOnitoring Dashboard (SEAMOD) will be of commercial interest to anyone seeking to deploy an ME project and is easily expandable to include tidal and wind energy site assessments. The integrated dashboard is being developed using state-of-the-art database and cloud computing methods and data-assimilative modeling tools that can be coupled with low-cost, rapidly deployable wave buoys and environmental sensing hardware. The combined software and hardware dashboard will reduce wave energy site characterization and wave climate monitoring costs by more than 60 percent and provide assessments that meet international industry standards. To realize a thriving global ME industry, the physical environment at a potential deployment site must be understood, not only for resource characterization, but also for optimization of device and power conversion performance. SEAMOD directly addresses these needs with a commercially marketable product. SEAMOD is a low-cost solution that provides comprehensive ME resource assessments, baseline environmental monitoring, and offshore characterizations required for successful ME development. The key technical objectives for Phase I were a series of software development goals, which when implemented with monitoring solutions, produced an initial proof-of-concept low-cost wave energy resources dashboard. In Phase II, the development of the prototype SEAMOD continued. The basic framework employed was the development of a revised dashboard and monitoring tool customized for ME applications by focusing on IEC site assessment and method requirements. Development was focused on the integration of full hindcast metocean products to provide hindcast resource characterization and environmental information. The final integrated dashboard provides a low-cost solution that delivers comprehensive, scalable, industry-standard energy resource assessments and offshore characterizations required for successful ME development. The integrated dashboard offers visibility of the most recent site modeling, measurements, and historical data. The application and integration of consensus-based standards for wave energy resource assessment, as determined by the International Electrotechnical Commission (IEC), are crucial for the impact and value of SEAMOD. SEAMOD includes monthly, seasonal, and yearly statistics, as well as the total 30-year record, offering temporal resolution of the IEC parameters to aid potential developers in determining the available wave energy resources in their area of interest.

16 TIDAL AND WAVE POWER↗

Arrow-wing supersonic cruise aircraft structural design concepts evaluation. Volume 4: Sections 15 through 21

The analyses performed to provide structural mass estimates for the arrow wing supersonic cruise aircraft are presented. To realize the full potential for structural mass reduction, a spectrum of approaches for the wing and fuselage primary structure design were investigated. The objective was: (1) to assess the relative merits of various structural arrangements, concepts, and materials; (2) to select the structural approach best suited for the Mach 2.7 environment; and (3) to provide construction details and structural mass estimates based on in-depth structural design studies. Production costs, propulsion-airframe integration, and advanced technology assessment are included.

Sakata, I. F.↗

Overview and Recommendations for Cyber Risk Assessment in Nuclear Power Plants

Digital instrumentation and control (I&C) systems are being deployed in nuclear power plants (NPPs) for both existing and advanced reactor designs. As I&C systems become more digitized to allow features like near autonomous control and remote operation, they introduce greater cyber risk to NPPs. Cyberattacks targeting industrial control systems (ICSs) are growing in both qualities and capabilities, which indicates that cybersecurity needs to be an integral part of risk assessment in the industry. Although there are some risk assessment methods in traditional information technology (IT) cybersecurity, the differences between IT and ICS cybersecurity make it infeasible to apply these risk assessment methods directly to ICSs. Some research has focused on risk assessment methods for ICSs, but few studies focus on applications to NPPs. Ideal risk frameworks for the nuclear industry are dynamic and account for system dependencies; this survey review focuses on such risk assessment methods both in and outside the nuclear field. In this article, the major challenges in cybersecurity risk assessment research are pointed out, and further research suggestions and considerations for cyber risk assessment in I&C systems are identified.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Assessment of the Impact of Realistic Sensor Physics and the Integration of Ex-Core Sensors on Reactor Power Synthesis

In the work documented in this report, a weighting function–based core power synthesis method was applied to multiple Monte Carlo N-Particle (MCNP) reactor models, which are informed based on simulated self-powered neutron detector (SPND) responses. The weighting function method used has been coined the point-based iterative (PBI) method. The goal of this application is to assess the impact of considering realistic sensor physics in the generation of the simulated SPND outputs as well as to consider how the synthesis is impacted based on the inclusion of ex-core detectors in the model. The NuScale small modular reactor (SMR) and Westinghouse AP1000 pressurized water reactor (PWR) are the models that served as the testbeds for the assessment of realistic sensor physics; this was achieved by using Geant4 SPND models in comparison with analytical models, such that the effect of electron transport in realistic SPND geometries in the Geant4 model can be understood in terms of synthesis error and convergence time. The comparison was considered for fuel burnup–induced perturbations, for a range of sensor string densities and synthesized power distribution axial fidelities. The Texas A&M Testing, Research, Isotopes, General Atomics Reactor (TAMU TRIGA) reactor MCNP model was used to assess the impact of ex-core sensors; this was done by performing synthesis with and without the ex-core detectors and by quantifying the synthesis error and number of iterations associated with Gaussian-type perturbations in many locations in the core. The TAMU TRIGA model was particularly pertinent for this study because of the interest in future experimental tests with SPNDs in this reactor, as well as the ease of modifying the MCNP model to include ex-core detectors with heterogeneously described response functions. Results from the comparison between the Geant4 and analytical SPND models indicate that similar average and maximum synthesis errors were obtained for burnup-induced perturbations in both the NuScale SMR and the AP1000. This was true for a range of sensor string densities and axial fidelities. However, there were marked differences between both the Geant4 and analytically informed models in terms of the iterations required to converge on the synthesized power distribution. Namely, the Geant4-informed models tended to lead to fewer iterations, except for a few sensor–core configurations that had particularly numerous iterations. Results from the ex-core sensor assessment with the TAMU TRIGA model indicate that the inclusion of ex-core sensors drastically reduces the synthesis error of Gaussian-type perturbations close to the edge of the core, and it slightly reduces synthesis errors for perturbations closer to the center of the core. This was achieved with a minimal increase in computational cost—that is, the number of iterations required for convergence. The errors were identified to be in the same location as the perturbation in the core, indicating that the methodology remains robust for unperturbed regions of the core. A secondary result from this study with the TAMU TRIGA was yielded by analysis of the neutron flux levels in the in-core and ex-core sensor locations of the core; these flux levels indicate that SPNDs could be used as both in-core and ex-core sensors, so long as the emitter material is sensitive to thermal neutrons. The results from these studies provide a quantitative understanding of the importance of considering realistic sensor physics and including ex-core sensors to perform accurate and timely power distribution synthesis of a reactor core.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Plug-In Electric Vehicle Fast Charge Station Operational Analysis with Integrated Renewables: Preprint

The growing, though still nascent, plug-in electric vehicle (PEV) market currently operates primarily via level 1 and level 2 charging in the United States. Fast chargers are still a rarity, but offer a confidence boost to oppose 'range anxiety' in consumers making the transition from conventional vehicles to PEVs. Because relatively no real-world usage of fast chargers at scale exists yet, theNational Renewable Energy Laboratory developed a simulation to help assess fast charging needs based on real-world travel data. This study documents the data, methods, and results of the simulation run for multiple scenarios, varying fleet sizes, and the number of charger ports. The grid impact of this usage is further quantified to assess the opportunity for integration of renewables;specifically, a high frequency of fast charging is found to be in demand during the late afternoons and evenings coinciding with grid peak periods. Proper integration of a solar array and stationary battery thus helps ease the load and reduces the need for new generator construction to meet the demand of a future PEV market.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

STATISTICAL SAMPLING FOR IN-SERVICE INSPECTION OF LIQUID WASTE TANKS AT THE SAVANNAH RIVER SITE

Savannah River Remediation, LLC (SRR) is implementing a statistical sampling strategy for In-Service Inspection (ISI) of Liquid Waste (LW) Tanks at the United States Department of Energy's Savannah River Site (SRS) in Aiken, South Carolina. As a component of SRS's corrosion control program, the ISI program assesses tank wall structural integrity through the use of ultrasonic testing (UT). The statistical strategy for ISI is based on the random sampling of a number of vertically oriented unit areas, called strips, within each tank. The number of strips to inspect was determined so as to attain, over time, a high probability of observing at least one of the worst 5% in terms of pitting and corrosion across all tanks. The probability estimation to determine the number of strips to inspect was performed using the hypergeometric distribution. Statistical tolerance limits for pit depth and corrosion rates were calculated by fitting the lognormal distribution to the data. In addition to the strip sampling strategy, a single strip within each tank was identified to serve as the baseline for a longitudinal assessment of the tank safe operational life. The statistical sampling strategy enables the ISI program to develop individual profiles of LW tank wall structural integrity that collectively provide a high confidence in their safety and integrity over operational lifetimes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advanced Instrumentation, Information, and Control System Technologies: Nondestructive Examination Technologies - FY11 Report

Licensees of commercial nuclear power plants in the US are expected to submit license renewal applications for the period of operation of 60 to 80 years which has also been referred to as long term operation (LTO). The greatest challenges to LTO are associated with degradation of passive components as active components are routinely maintained and repaired or placed through maintenance programs. Some passive component degradation concerns include stress corrosion cracking (SCC) of metal components, radiation induced embrittlement of the reactor pressure vessel (RPV), degradation of buried piping, degradation of concrete containment structures, and degradation of cables. Proactive management of passive component aging employs three important elements including online monitoring of degradation, early detection of degradation at precursor stages, and application of prognostics for the prediction of remaining useful life (RUL). This document assesses several nondestructive examination (NDE) measurement technologies for integration into proactive aging management programs. The assessment is performed by discussing the three elements of proactive aging management identified above, considering the current state of the industry with respect to adopting these key elements, and analyzing measurement technologies for monitoring large cracks in metal components, monitoring early degradation at precursor stages, monitoring the degradation of concrete containment structures, and monitoring the degradation of cables. Specific and general needs have been identified through this assessment. General needs identified include the need for environmentally rugged sensors are needed that can operate reliably in an operating reactor environment, the need to identify parameters from precursor monitoring technologies that are unambiguously correlated with the level of pre-macro defect damage, and a methodology for identifying regions where precursor damage is most likely to initiate.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Methodological guidelines on concrete degradation based on predictive models and the release of MOSAIC for industry use

In light-water reactors (LWRs), the concrete biological shield (CBS) designates the concrete structure directly facing the reactor pressure vessel (RPV). The primary function of the CBS is to protect equipment and personnel from the neutron and gamma radiation exiting the RPV. Most CBSs in operation in the United States also provide structural support to the RPV. Based on a long-term structural analysis, the structural integrity of the CBS to transfer the in-service passive load to the foundation, dynamic loading during an earthquake, and thermal loading during a loss-of-coolant accident (LOCA) must be maintained. Based on test reactor data for accelerated conditions, the mechanical properties of irradiated concrete are affected when exposed to neutron fluence higher than ≈ 10 19 n.cm -2 (E > 0.1 MeV). At 80 years of operation, the fluence estimates at the surface of the CBS range between 1×10 19 and 7×10 19 n.cm -2 (E > 0.1 MeV): the fluence value depends mostly on the design. Although fluence attenuates through the CBS by virtue of the shielding properties of concrete, about 5% to 10% of the CBS wall depth is affected by high fluence. The main degradation mechanism is the so-called radiation-induced volumetric expansion (RIVE) caused by the amorphization of aggregate-forming minerals. RIVE causes large deformation of up to 18% in pure quartz, and it also reduces the structural properties of concrete. The structural effects of long-term exposure to fast neutron irradiation in LWRs was studied in the report entitled “Assessment of the Effect of the Irradiation-Induced Degradation on the In-Service Structural Performance of the Concrete Biological Shields” (M3LW-23OR0403013). This report illustrates that (1) irradiation-induced damage expands further than the region subject to a cumulative fluence of 10 19 n.cm -2 (E > 0.1 MeV) to reach the steel reinforcement location, and (2) the irradiation-induced damage region shows no substantial residual bearing capacity and should not be accounted for in the integrity assessment of the CBS.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗